Schweigert Plan Set 12-1-221) THIS PHOTOVOLTAIC (PV) SYSTEM SHALL COMPLY WITH THE
CALIFORNIA ELECTRIC CODE (CEC) ARTICLE 690, ALL
MANUFACTURERS’S LISTING AND INSTALLATION INSTRUCTIONS,
AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY
HAVING JURISDICTION’S (AHJ) APPLICABLE CODES.
2) THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE
BATTERIES
3) TOTAL SQ.FT. OF ROOF: 418.25 SQ. FT. / 3014.50 SQ.FT.≈ 13.87%
GENERAL NOTES NEW PV SYSTEM: 8.505 kWp
SCHWEIGERT RESIDENCE
932 SEPTEMBER DR
CUPERTINO, CA 95014
ASSESSOR'S #: 36214005
OWNER
NAME:JEREMY SCHWEIGERT
PROJECT MANAGER
NAME:BARRY CINNAMON
PHONE:(408) 883-7000
CONTRACTOR
NAME:CINNAMON ENERGY SYSTEMS, INC.
PHONE:(408) 883-7000
AUTHORITIES HAVING JURISDICTION
BUILDING: CUPERTINO, CA
ZONING: CUPERTINO, CA
UTILITY: PG&E
DESIGN SPECIFICATIONS
OCCUPANCY: II
CONSTRUCTION: SINGLE-FAMILY
ZONING: RESIDENTIAL
GROUND SNOW LOAD: 0 PSF
WIND EXPOSURE: B
WIND SPEED: 110 MPH
APPLICABLE CODES & STANDARDS
BUILDING: CBC 2019 CRC 2019
ELECTRICAL: NEC 2017, CEC 2019
FIRE: CFC 2019
PROJECT INFORMATION
B F
A D E
2
3
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM: 8.505 kWp
ENGINEER OF RECORD
12.1.2022
DESIGN BY:S.G.
SCHWEIGERT
RESIDENCE
932 SEPTEMBER DR
CUPERTINO, CA 95014
APN: 36214005
PAPER SIZE: 11" x 17" (ANSI B)
A C D E G H
B C F G H
1
4
5
6
CONTRACTOR
CINNAMON ENERGY SYSTEMS, INC.
PHONE:
LIC. NO.:
DATE:
REVISIONS
HIC. NO.:
ELE. NO.:
ADDRESS:
(408) 883-7000
809 UNIVERSITY AVE LOS
GATOS, CA 95032
#976065, C-46 SOLAR
T-001.00
COVER PAGE
(SHEET 1)
01 AERIAL PHOTO
NOT TO SCALE
N
EW
S
02 PLAT MAP
NOT TO SCALE
SHEET LIST TABLE
SHEET NUMBER SHEET TITLE
T-001 COVER PAGE
A-101 SITE PLAN
A-102 ELECTRICAL PLAN
A-103 SOLAR ATTACHMENT PLAN
E-601 LINE DIAGRAM
E-602 PLACARDS
S-501 ASSEMBLY DETAILS
R-001 RESOURCE DOCUMENT
R-002 RESOURCE DOCUMENT
R-003 RESOURCE DOCUMENT
R-004 RESOURCE DOCUMENT
R-005 RESOURCE DOCUMENT
W VALLEY FWYSEPTEMBER DRR-006 RESOURCE DOCUMENT
Arnold Hom
01/09/23
01/12/23
BLD-2022-2325
Haley McKee
GENERAL NOTES
1. FIELD VERIFY ALL MEASUREMENTS
2. ITEMS BELOW MAY NOT BE ON THIS PAGE
PROPERTY LINE
1. SOLAR PHOTOVOLTAIC SYSTEM TO BE INSTALLED ON RESIDENTIAL STRUCTURE.
2. THIS PROJECT HAS BEEN DESIGNED IN COMPLIANCE WITH THE CBC SECTION 1609
TO WITHSTAND A BASIC WIND SPEED OF 110 MPH (3 SECOND GUST), WIND
EXPOSURE B.
3. THE ROOF MEMBERS ARE 2X6 RAFTER AT 24" ON CENTER. CONNECTION TO
STRUCTURE SHALL NOT BE WITHIN 6" OF NAILING PLATES.
4. THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,
MECHANICAL OR BUILDING ROOF VENTS.
5. ALL CONDUCTORS AND CONDUITS MOUNTED ON ROOF SHALL BE MINIMUM 3 3/4"
ABOVE ROOF SURFACE (INCLUDING CABLES UNDERNEATH MODULES AND
RACKING).
6. ROOF ACCESS POINTS SHALL BE PROVIDED PER THE FOLLOWING (CRC R324.7.1,
CBC 3111.2.1):
LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUND LADDERS OVER
OPENINGS SUCH AS DOORS OR WINDOWS.
LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS
WHERE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS
SUCH AS: TREE LIMBS, WIRES, OR SIGNS
CONSTRUCTION NOTES
N
EW
S
01/16" = 1'-0"
SITE PLAN01 8'16'
B F
A D E
2
3
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM: 8.505 kWp
ENGINEER OF RECORD
12.1.2022
DESIGN BY:S.G.
SCHWEIGERT
RESIDENCE
932 SEPTEMBER DR
CUPERTINO, CA 95014
APN: 36214005
PAPER SIZE: 11" x 17" (ANSI B)
A C D E G H
B C F G H
1
4
5
6
CONTRACTOR
CINNAMON ENERGY SYSTEMS, INC.
PHONE:
LIC. NO.:
DATE:
REVISIONS
HIC. NO.:
ELE. NO.:
ADDRESS:
(408) 883-7000
809 UNIVERSITY AVE LOS
GATOS, CA 95032
#976065, C-46 SOLAR
A-101.00
(SHEET 2)
AREA OF WORK
ENTRANCE
SITE PLAN
METER/MAIN (UPGRADED)SEPTEMBER DRINVERTER
21'-11"
7'-8"31'-1"
22'-7"
CAL-FIRE ROOF LADDER
ACCESS POINT PER
CRC 2019 SEC. R324.6 TYP.
CAL-FIRE ROOF LADDER
ACCESS POINT PER
CRC 2019 SEC. R324.6 TYP.
Arnold Hom
01/09/23
MODULE:
REС
REC405AA PURE
405 WATTS
40''
71.7"
GENERAL NOTES
1. FIELD VERIFY ALL MEASUREMENTS
2. ITEMS BELOW MAY NOT BE ON THIS PAGE
FIRE CLEARANCE
MODULE STRINGING
MODULE STRINGING
B F
A D E
2
3
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM: 8.505 kWp
ENGINEER OF RECORD
12.1.2022
DESIGN BY:S.G.
SCHWEIGERT
RESIDENCE
932 SEPTEMBER DR
CUPERTINO, CA 95014
APN: 36214005
PAPER SIZE: 11" x 17" (ANSI B)
A C D E G H
B C F G H
1
4
5
6
CONTRACTOR
CINNAMON ENERGY SYSTEMS, INC.
PHONE:
LIC. NO.:
DATE:
REVISIONS
HIC. NO.:
ELE. NO.:
ADDRESS:
(408) 883-7000
809 UNIVERSITY AVE LOS
GATOS, CA 95032
#976065, C-46 SOLAR
N
E
W
S A-102.00
(SHEET 3)
01/8" = 1'-0"
ELECTRICAL PLAN01 4' 8'
ELECTRICAL PLAN
(N) (1) INVERTER
(N) (1) METER/MAIN (UPGRADED)
A
(N) (1) JUNCTION BOX
EXTERIOR PV EQUIPMENT
ARRAY 2 - 5.670 kW
[x14] (N) MODULES
TILT: 18 DEGREES
ROOF PITCH: 4:12
AZIMUTH: 250 DEGREES
A
B
A
A
AA
B B
B B
B B
B B
B
B
A A A A
AA
ARRAY 1 - 2.835 kW
[x7] (N) MODULES
TILT: 18 DEGREES
ROOF PITCH: 4:12
AZIMUTH: 160 DEGREES
3' FIRE ACCESS PATH
18" FIRE ACCESS PATH
18" FIRE ACCESS PATH
18" FIRE ACCESS PATH
18" FIRE ACCESS PATH
18" FIRE ACCESS PATH
18" FIRE ACCESS PATH
3' FIRE ACCESS PATH
CAL-FIRE ROOF LADDER
ACCESS POINT PER
CRC 2019 SEC. R324.6 TYP.
CAL-FIRE ROOF LADDER
ACCESS POINT PER
CRC 2019 SEC. R324.6 TYP.
Arnold Hom
01/09/23
GENERAL NOTES
1. FIELD VERIFY ALL MEASUREMENTS
2. ITEMS BELOW MAY NOT BE ON THIS PAGE
ROOF RAFTERS
MODULE:
REС
REC405AA PURE
405 WATTS
40''
71.7"
B F
A D E
2
3
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM: 8.505 kWp
ENGINEER OF RECORD
12.1.2022
DESIGN BY:S.G.
SCHWEIGERT
RESIDENCE
932 SEPTEMBER DR
CUPERTINO, CA 95014
APN: 36214005
PAPER SIZE: 11" x 17" (ANSI B)
A C D E G H
B C F G H
1
4
5
6
CONTRACTOR
CINNAMON ENERGY SYSTEMS, INC.
PHONE:
LIC. NO.:
DATE:
REVISIONS
HIC. NO.:
ELE. NO.:
ADDRESS:
(408) 883-7000
809 UNIVERSITY AVE LOS
GATOS, CA 95032
#976065, C-46 SOLAR
N
E
W
S
01/8" = 1'-0"
SOLAR ATTACHMENT PLAN 01 4' 8'A-103.00
(SHEET 4)
SOLAR ATTACHMENT PLAN
FLUSH MOUNT SOLAR MODULES
ATTACHED TO ROOF SURFACE
(SEE SHEET S-501.00 FOR MOUNTING DETAILS)
ROOF MATERIAL IS ASPHALT SHINGLE
26'-10"
12'-9"
Arnold Hom
01/09/23
(1) SOLAR EDGE
SE7600H-
US000BNU4 (240V)
JUNCTION BOX
(21)SOLAR EDGE
S440 POWER
OPTIMIZER
(21)REC REC405AA PURE
405 WATTS
EQUIPMENT RIGHT OF
LINE IS (E) EXISTING
UNLESS OTHERWISE
NOTED.
PV SYSTEM EQUIPPED WITH RAPID
SHUTDOWN DISCONNECT PER CEC 690.12
SYSTEM COMPLIANT WITH CEC 690.13
EQUIPMENT LEFT OF
LINE IS (N) NEW
G
2
3
1 13 - E-602 FOR INDICATED LEBELS
1 1 1 2 4 7 10
8 11
9 12
3 5
(C) (CB) (C) (DC) (INV)(POI) (AC) (D)
A MODULE STRINGING
TO UTILITY
GRID (OH)
L2
N
L1
(E)GROUNDING
ELECTRODE
GROUND
ROD
6
13
L1
L2
N
GG
(N)METER/MAIN (UPGRADED)
240/120 V 1Ø, 3W
MAIN BUSS: 200A
MAX BREAKER SIZE:
(200 A x 1.2 ) - 200 A = 40 A
GN
TO (E)
LOADS
(E)
UTILITY
METER
(N)MAIN
200A
L2
L1
N
L2
L1
N (N)
40A/2P
CB1
IN BRANCH
1IN BRANCH
10
11
А
А
CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS
ID TYPICAL CONDUCTOR CONDUIT CURRENT-CARRYING
CONDUCTORS IN CONDUIT OCPD EGC TEMP. CORR.
FACTOR
CONDUIT FILL
FACTOR
CONT.
CURRENT
MAX. CURRENT
(125%)BASE AMP.DERATED
AMP.TERM. TEMP. RATING AMP. @ TERMINAL
1 2 10 AWG PV WIRE, COPPER FREE AIR 2 N/A 6 AWG BARE, COPPER 1 (29.2 °C)1 15A 18.75A 55A 55A 75°C 50A
2 1 10 AWG THWN-2, COPPER 0.75'' DIA EMT 4 N/A 10 AWG THWN-2, COPPER 1 (29.2 °C)0.8 15A 18.75A 40A 32A 75°C 35A
3 1 8 AWG THWN-2, COPPER 0.75'' DIA EMT 2 40A 8 AWG THWN-2, COPPER 1 (29.2 °C)1 32A 40A 55A 55A 75°C 50A
INVERTERS
OCPDS
POWER OPTIMIZERS
MODULES
ASHRAE EXTREME LOW -3°C (26.6°F), SOURCE: MOUNTAIN VIEW (SUNN (37.42°; -122.05°)
ASHRAE 2% HIGH 29.2°C (84.6°F), SOURCE: MOUNTAIN VIEW (SUNN (37.42°; -122.05°)
REF. QTY. RATED CURRENT MAX VOLTAGE
CB1 1 40A 240VAC
REF. QTY.MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING
PM1-21 21 REC REC405AA PURE 405W 385.9W 10.14A 9.56A 48.9V 42.4V -0.117V/°C (-0.24%/°C) 25A
REF. QTY.MODEL RATED INPUT POWER MAX OUTPUT CURRENT MAX INPUT ISC MAX DC VOLTAGE WEIGHTED EFFICIENCY
PO1-21 21 SOLAR EDGE S440 440W 15A 14.5A 60V 98.6%
REF. QTY.MAKE AND MODEL AC
VOLTAGE GROUND OCPD
RATING
RATED
POWER
MAX OUTPUT
CURRENT
MAX INPUT
CURRENT
MAX INPUT
VOLTAGE
CEC WEIGHTED
EFFICIENCY
I1 1 SOLAR EDGE SE7600H-US000BNU4 HD-WAVE (240V) 240V FLOATING 40A 7600W 32A 20A 480V 99.0%
SYSTEM SUMMARY
INVERTER #1
STRING #1 STRING #2
POWERBOX MAX OUTPUT CURRENT 15A 15A
OPTIMIZERS IN SERIES 11 10
NOMINAL STRING VOLTAGE 400V 400V
ARRAY OPERATING CURRENT 11.14A 10.13A
ARRAY STC POWER 8,505W
ARRAY PTC POWER 8,104W
MAX AC CURRENT 32A
MAX AC POWER 7,600W
DERATED (CEC) AC POWER 7,600W
E-601.00
(SHEET 5)
B F
A D E
2
3
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM: 8.505 kWp
ENGINEER OF RECORD
12.1.2022
DESIGN BY:S.G.
SCHWEIGERT
RESIDENCE
932 SEPTEMBER DR
CUPERTINO, CA 95014
APN: 36214005
PAPER SIZE: 11" x 17" (ANSI B)
A C D E G H
B C F G H
1
4
5
6
CONTRACTOR
CINNAMON ENERGY SYSTEMS, INC.
PHONE:
LIC. NO.:
DATE:
REVISIONS
HIC. NO.:
ELE. NO.:
ADDRESS:
(408) 883-7000
809 UNIVERSITY AVE LOS
GATOS, CA 95032
#976065, C-46 SOLAR
LINE DIAGRAM
Arnold Hom
01/09/23
MAIN DISTRIBUTION
UTILITY DISCONNECT
FRONT
PV ARRAY
BACK
!CAUTION!
POWER TO THIS BUILDING IS ALSO SUPPLIED
FROM ROOF MOUNTED SOLAR ARRAYS WITH
SAFETY DISCONNECTS AS SHOWN:
E-602.00
(SHEET 6)
B F
A D E
2
3
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM: 8.505 kWp
ENGINEER OF RECORD
12.1.2022
DESIGN BY:S.G.
SCHWEIGERT
RESIDENCE
932 SEPTEMBER DR
CUPERTINO, CA 95014
APN: 36214005
PAPER SIZE: 11" x 17" (ANSI B)
A C D E G H
B C F G H
1
4
5
6
CONTRACTOR
CINNAMON ENERGY SYSTEMS, INC.
PHONE:
LIC. NO.:
DATE:
REVISIONS
HIC. NO.:
ELE. NO.:
ADDRESS:
(408) 883-7000
809 UNIVERSITY AVE LOS
GATOS, CA 95032
#976065, C-46 SOLAR
NEWSPV ARRAY
PLACARDS CAUTION
DUAL POWER SOURCE
SECOND SOURCE IS
PHOTOVOLTAIC SYSTEM
PHOTOVOLTAIC SYSTEM
AC DISCONNECT
OPERATING VOLTAGE VOLTS
OPERATING CURRENT AMPS
240
WARNING
ELECTRIC SHOCK HAZARD
IF GROUND FAULT IS INDICATED
ALL NORMALLY GROUNDED
CONDUCTORS MAY BE
UNGROUNDED AND ENERGIZED
PHOTOVOLTAIC SYSTEM
EQUIPPED WITH
RAPID SHUTDOWN
PHOTOVOLTAIC AC
DISCONNECT
PV SYSTEM
DISCONNECT FOR UTILITY
OPERATION
WARNING
INVERTER OUTPUT CONNECTION
DO NOT RELOCATE THIS
OVERCURRENT DEVICE
LABEL LOCATION:
(AC) (POI)
PER CODE:
CEC 690.14.C.2
LABEL LOCATION:
(AC)
LABEL LOCATION:
(POI)
PER CODE:
CEC 705.12.D.7
LABEL LOCATION:
(INV)
PER CODE:
CEC 690.5(C)
LABEL LOCATION:
(AC) (POI)
PER CODE:
CEC 690.54
LABEL LOCATION:
(D)(POI)
PER CODE:
CEC 690.64.B.4
LABEL LOCATION:
(POI)
PER CODE:
CEC 705.12.D.7
WARNING
PHOTOVOLTAIC POWER SOURCE
LABEL LOCATION:
PHOTOVOLTAIC
DC DISCONNECT
MAXIMUM POWER-
POINT CURRENT (Imp) A
MAXIMUM POWER-
POINT VOLTAGE (Vmp) V
MAXIMUM SYSTEM
VOTTAGE (Voc) V
SHORT-CIRCUIT
CURRENT (Isc) A30
(C)(IC) (CB)
PER CODE:
СRС R331.2
LABEL LOCATION:
(DC)(INV)
PER CODE:
СEС 690.14.C2
LABEL LOCATION:
(DC)(INV)
PER CODE:
СEС 690.53
480
400
20
32
1
3
5
6
8
9
10
11
12
13
WARNING
ELECTRIC SHOCK HAZARD
THE DC CONDUCTORS OF THE
PHOTOVOLTAIC SYSTEM ARE UNGROUNDED
AND MAY BE ENERGIZED
LABEL LOCATION:
(DC)
PER CODE:
CEC 690.35(F) - UNGROUNDED
SYSTEM
2
WARNING
ELECTRIC SHOCK HAZARD
THE DC CONDUCTORS OF THE
PHOTOVOLTAIC SYSTEM ARE UNGROUNDED
AND MAY BE ENERGIZED
LABEL LOCATION:
(INV)
PER CODE:
CEC 690.35(F) - UNGROUNDED
SYSTEM
4
WARNING DUAL POWER SOURCE
POWER IS BEING SUPPLIED TO THIS
PANEL FROM THE UTILITY AND A SOLAR
PV SYSTEM THE SOLAR PV
DISCONNECT IS LOCATED
LABEL LOCATION:
(POI)
PER CODE:
CEC 705.12(D)(4), 690.56(B) - ON
PANEL COVER
7
NE SIDE OF THE HOUSE
Arnold Hom
01/09/23
SHEET KEYNOTES
1. ROOF MATERIAL: ASPHALT SHINGLE
2. ROOF STRUCTURE: COLLAR TIE
3. ATTACHMENT TYPE: QUICK MOUNT PV QMLM: L-MOUNT
4. MODULE MANUFACTURER: REC
5. MODULE MODEL: REC405AA PURE
6. MODULE LENGTH: 71.7''
7. MODULE WIDTH: 40'
8. MODULE WEIGHT: 45 LBS.
9. SEE SHEET A-103 FOR DIMENSION(S)
10. MIN. FIRE OFFSET: 18" FROM RIDGE, AT LEAST 2 PATHWAY
TO A STREET OR DRIVEWAY MINIMUM 3' WIDE
11. RAFTER SPACING: 24 IN. O.C.
12. RAFTER SIZE: 2X6 IN. NOMINAL
13. LAG BOLT DIAMETER: 5/16 IN.
14. LAG BOLT EMBEDMENT: 2-1/2 IN.
15. TOTAL # OF ATTACHMENTS: 39
16. TOTAL AREA: 418.25 SQ. FT.
17. TOTAL WEIGHT: 1078.89 LBS.
18. WEIGHT PER ATTACHMENT: 27.66 LBS.
19. DISTRIBUTED LOAD: 2.58 PSF.
20. MAX. HORIZONTAL STANDOFF: 72 IN.
21. MAX. VERTICAL STANDOFF: IN ACCORDANCE WITH MODULE
MANUFACTURER'S INSTRUCTIONS.
22. STANDOFF STAGGERING: YES
23. RAIL MANUFACTURER (OR EQUIV.): IRONRIDGE
24. RAIL MODEL (OR EQUIVALENT): XR-10
25. RAIL WEIGHT: 0.68 PLF.
26. MAX. RAFTER SPAN: N/A
27. MODULE CLEARANCE: 3 IN. MIN., 6 IN. MAX.
S-501
D5
20
11
1214 13 15 18 22
ROOF SLOPE910
10
6 21
7
3
1
5 4 6
27
2524 23
2
S-501
D4
1. FIELD VERIFY ALL MEASUREMENTS
GENERAL NOTES
B F
A D E
2
3
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM: 8.505 kWp
ENGINEER OF RECORD
12.1.2022
DESIGN BY:S.G.
SCHWEIGERT
RESIDENCE
932 SEPTEMBER DR
CUPERTINO, CA 95014
APN: 36214005
PAPER SIZE: 11" x 17" (ANSI B)
A C D E G H
B C F G H
1
4
5
6
CONTRACTOR
CINNAMON ENERGY SYSTEMS, INC.
PHONE:
LIC. NO.:
DATE:
REVISIONS
HIC. NO.:
ELE. NO.:
ADDRESS:
(408) 883-7000
809 UNIVERSITY AVE LOS
GATOS, CA 95032
#976065, C-46 SOLAR
S-501.00
(SHEET 7)
ASSEMBLY DETAILS
D1 RACKING DETAIL (TRANSVERSE)
NOT TO SCALE
D3 RACKING DETAIL (TOP)
NOT TO SCALE
D2 RACKING DETAIL (LONGITUDINAL)
NOT TO SCALE
D4 DETAIL (TRANSVERSE)
NOT TO SCALE D5 DETAIL (LONGITUDINAL)
NOT TO SCALE
7'-0" 5 '-0" 7'-0" 4'-0"
Arnold Hom
01/09/23
B F
A D E
2
3
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM: 8.505 kWp
ENGINEER OF RECORD
12.1.2022
DESIGN BY:S.G.
SCHWEIGERT
RESIDENCE
932 SEPTEMBER DR
CUPERTINO, CA 95014
APN: 36214005
PAPER SIZE: 11" x 17" (ANSI B)
A C D E G H
B C F G H
1
4
5
6
CONTRACTOR
CINNAMON ENERGY SYSTEMS, INC.
PHONE:
LIC. NO.:
DATE:
REVISIONS
HIC. NO.:
ELE. NO.:
ADDRESS:
(408) 883-7000
809 UNIVERSITY AVE LOS
GATOS, CA 95032
#976065, C-46 SOLAR
R-001.00
(SHEET 8)
RESOURCE DOCUMENT
Arnold Hom
01/09/23
B F
A D E
2
3
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM: 8.505 kWp
ENGINEER OF RECORD
12.1.2022
DESIGN BY:S.G.
SCHWEIGERT
RESIDENCE
932 SEPTEMBER DR
CUPERTINO, CA 95014
APN: 36214005
PAPER SIZE: 11" x 17" (ANSI B)
A C D E G H
B C F G H
1
4
5
6
CONTRACTOR
CINNAMON ENERGY SYSTEMS, INC.
PHONE:
LIC. NO.:
DATE:
REVISIONS
HIC. NO.:
ELE. NO.:
ADDRESS:
(408) 883-7000
809 UNIVERSITY AVE LOS
GATOS, CA 95032
#976065, C-46 SOLAR
R-002.00
(SHEET 9)
RESOURCE DOCUMENT
Arnold Hom
01/09/23
B F
A D E
2
3
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM: 8.505 kWp
ENGINEER OF RECORD
12.1.2022
DESIGN BY:S.G.
SCHWEIGERT
RESIDENCE
932 SEPTEMBER DR
CUPERTINO, CA 95014
APN: 36214005
PAPER SIZE: 11" x 17" (ANSI B)
A C D E G H
B C F G H
1
4
5
6
CONTRACTOR
CINNAMON ENERGY SYSTEMS, INC.
PHONE:
LIC. NO.:
DATE:
REVISIONS
HIC. NO.:
ELE. NO.:
ADDRESS:
(408) 883-7000
809 UNIVERSITY AVE LOS
GATOS, CA 95032
#976065, C-46 SOLAR
R-003.00
(SHEET 10)
RESOURCE DOCUMENT
Arnold Hom
01/09/23
B F
A D E
2
3
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM: 8.505 kWp
ENGINEER OF RECORD
12.1.2022
DESIGN BY:S.G.
SCHWEIGERT
RESIDENCE
932 SEPTEMBER DR
CUPERTINO, CA 95014
APN: 36214005
PAPER SIZE: 11" x 17" (ANSI B)
A C D E G H
B C F G H
1
4
5
6
CONTRACTOR
CINNAMON ENERGY SYSTEMS, INC.
PHONE:
LIC. NO.:
DATE:
REVISIONS
HIC. NO.:
ELE. NO.:
ADDRESS:
(408) 883-7000
809 UNIVERSITY AVE LOS
GATOS, CA 95032
#976065, C-46 SOLAR
R-004.00
(SHEET 11)
RESOURCE DOCUMENT
Arnold Hom
01/09/23
B F
A D E
2
3
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM: 8.505 kWp
ENGINEER OF RECORD
12.1.2022
DESIGN BY:S.G.
SCHWEIGERT
RESIDENCE
932 SEPTEMBER DR
CUPERTINO, CA 95014
APN: 36214005
PAPER SIZE: 11" x 17" (ANSI B)
A C D E G H
B C F G H
1
4
5
6
CONTRACTOR
CINNAMON ENERGY SYSTEMS, INC.
PHONE:
LIC. NO.:
DATE:
REVISIONS
HIC. NO.:
ELE. NO.:
ADDRESS:
(408) 883-7000
809 UNIVERSITY AVE LOS
GATOS, CA 95032
#976065, C-46 SOLAR
R-005.00
(SHEET 12)
RESOURCE DOCUMENT
Arnold Hom
01/09/23
B F
A D E
2
3
UNAUTHORIZED USE OF THIS
DRAWING SET WITHOUT WRITTEN
PERMISSION FROM CONTRACTOR IS IN
VIOLATION OF U.S. COPYRIGHT LAWS
AND WILL BE SUBJECT TO CIVIL
DAMAGES AND PROSECUTIONS.
NEW PV SYSTEM: 8.505 kWp
ENGINEER OF RECORD
12.1.2022
DESIGN BY:S.G.
SCHWEIGERT
RESIDENCE
932 SEPTEMBER DR
CUPERTINO, CA 95014
APN: 36214005
PAPER SIZE: 11" x 17" (ANSI B)
A C D E G H
B C F G H
1
4
5
6
CONTRACTOR
CINNAMON ENERGY SYSTEMS, INC.
PHONE:
LIC. NO.:
DATE:
REVISIONS
HIC. NO.:
ELE. NO.:
ADDRESS:
(408) 883-7000
809 UNIVERSITY AVE LOS
GATOS, CA 95032
#976065, C-46 SOLAR
R-006.00
(SHEET 13)
RESOURCE DOCUMENT
Arnold Hom
01/09/23