Title 24BUILDING ENERGY ANALYSIS REPORT
PROJECT:
Project Designer:
Report Prepared by:
Job Number:
Date:
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program h as approval and is
authorized by the California Energy Commission for use with both the Residential and Nonresidential 2019 Building Energy Efficiency Standards.
This program developed by EnergySoft Software – www.energysoft.com.
1448 S. Stelling Rd
Cupertino, CA
(408) 455-3793
20713 Rodrigues Ave
New Residence
Cupertino, CA 95014
P.O. BOX 1301
MECONE INC.
Radik Musin
Murrieta, CA 92564
(951) 445-7213
200924
10/21/2022
SEAN HATCH
01/09/23
TABLE OF CONTENTS
Form MF-1R Mandatory Measures Summary
Cover Page
Table of Contents
Form CF1R-PRF-01-E Certificate of Compliance
Form RMS-1 Residential Measures Summary
21
1
2
3
19
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
ProjectName:NewResidence CalculationDate/Time:2022-10-21T19:20:14-07:00 (Page 1 of16)
CalculationDescription:Title 24 Analysis InputFile Name:Title 24 -20713Rodriguess Ave (Rev-5).ribd19x
Registration Number:Registration Date/Time:HERSProvider:
CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version:2019.2.000
Schema Version:rev 20200901
Report Generated:2022-10-21 19:25:02
GENERAL INFORMATION
01 ProjectName NewResidence
02 RunTitle Title 24 Analysis
03 ProjectLocation 20713Rodrigues Ave
04 City Cupertino 05 Standards Version 2019
06 Zip code 95014 07 Software Version EnergyPro 8.3
08 Climate Zone 4 09 FrontOrientation(deg/Cardinal) 180
10 Building Type Single family 11 Number ofDwelling Units 1
12 ProjectScope NewConstruction 13 Number ofBedrooms 7
14 AdditionCond.Floor Area (ft2) 0 15 Number ofStories 2
16 Existing Cond.Floor Area (ft2) n/a 17 FenestrationAverage U-factor 0.31
18 Total Cond.Floor Area (ft2) 4716.5 19 Glazing Percentage (%) 24.16%
20 ADU Bedroom Count 1 21 ADU Conditioned Floor Area 750
22 Is Natural Gas Available? Yes
COMPLIANCE RESULTS
01 Building Complies withComputer Performance
02 This building incorporates features thatrequire field testing and/or verificationbya certified HERS rater under the supervisionofa CEC-approved HERS provider.
03 This building incorporates one or more Special Features shownbelow
220-P010180856B-000-000-0000000-0000 2022-11-14 16:55:19 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
ProjectName:NewResidence CalculationDate/Time:2022-10-21T19:20:14-07:00 (Page 2 of16)
CalculationDescription:Title 24 Analysis InputFile Name:Title 24 -20713Rodriguess Ave (Rev-5).ribd19x
Registration Number:Registration Date/Time:HERSProvider:
CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version:2019.2.000
Schema Version:rev 20200901
Report Generated:2022-10-21 19:25:02
ENERGYDESIGN RATING
Energy DesignRatings Compliance Margins
Efficiency¹(EDR)Total²(EDR)Efficiency¹(EDR) Total²(EDR)
Standard Design 44.4 25.7
Proposed Design 43 24.8 1.4 0.9
RESULT:3: COMPLIES
1:Efficiency EDR includes improvements to the building envelope and more efficient equipment
2:Total EDR includes efficiency and demand response measures such as photovoltaic (PV)systems and batteries
3:Building complies when efficiency and total compliance margins are greater than or equal to zero
• Standard Design PV Capacity:4.59 kWdc
ENERGYUSE SUMMARY
EnergyUse (kTDV/ft2-yr)Standard Design Proposed Design Compliance Margin PercentImprovement
Space Heating 19.76 17.77 1.99 10.1
Space Cooling 10.05 11.56 -1.51 -15
IAQVentilation 4.28 1.24 3.04 71
Water Heating 10.87 11.93 -1.06 -9.8
Self Utilization/Flexibility Credit n/a 0 0 n/a
Compliance Energy Total 44.96 42.5 2.46 5.5
REQUIRED PV SYSTEMS -SIMPLIFIED
01 02 03 04 05 06 07 08 09 10 11 12
DC System Size
(kWdc)Exception Module Type Array Type Power Electronics CFI Azimuth
(deg)
Tilt
Input
ArrayAngle
(deg)
Tilt:(x in
12)
Inverter Eff.
(%)
Annual
Solar Access
(%)
4.25 NA Standard Fixed none false 180 Degre
es 22 4.85 96 100
220-P010180856B-000-000-0000000-0000 2022-11-14 16:55:19 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
ProjectName:NewResidence CalculationDate/Time:2022-10-21T19:20:14-07:00 (Page 3 of16)
CalculationDescription:Title 24 Analysis InputFile Name:Title 24 -20713Rodriguess Ave (Rev-5).ribd19x
Registration Number:Registration Date/Time:HERSProvider:
CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version:2019.2.000
Schema Version:rev 20200901
Report Generated:2022-10-21 19:25:02
REQUIRED SPECIAL FEATURES
The following are features that must be installed as condition for meeting the modeled energy performance for this computer analysis.
• IAQVentilation System:as lowas 0.1 W/CFM
• Floor has high level of insulation
• Insulation belowroof deck
• Northwest Energy Efficiency Alliance (NEEA)rated heat pump water heater; specific brand/model, or equivalent, must be installed
HERS FEATURE SUMMARY
The following is a summary of the features that must be field-verified by a certified HERSRater as a condition for meeting the modeled energy performance for this computer analysis.Additional
detail is provided in the buildng tables below.Registered CF2Rs and CF3Rs are required to be completed in the HERSRegistry
Building-level Verifications:
• Quality insulation installation (QII)
• Indoor air quality ventilation
• Kitchen range hood
Cooling System Verifications:
• Minimum Airflow
• Verified EER
• Verified SEER
• Verified Refrigerant Charge
• Fan Efficacy Watts/CFM
Heating System Verifications:
• Verified HSPF
• Verified heat pump rated heating capacity
HVAC Distribution System Verifications:
• Duct leakage testing
Domestic Hot Water System Verifications:
• --None --
BUILDING -FEATURES INFORMATION
01 02 03 04 05 06 07
ProjectName Conditioned Floor Area (ft2)Number ofDwelling
Units Number ofBedrooms Number ofZones Number ofVentilation
Cooling Systems
Number ofWater
Heating Systems
NewResidence 4716.5 1 7 3 0 1
220-P010180856B-000-000-0000000-0000 2022-11-14 16:55:19 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
ProjectName:NewResidence CalculationDate/Time:2022-10-21T19:20:14-07:00 (Page 4 of16)
CalculationDescription:Title 24 Analysis InputFile Name:Title 24 -20713Rodriguess Ave (Rev-5).ribd19x
Registration Number:Registration Date/Time:HERSProvider:
CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version:2019.2.000
Schema Version:rev 20200901
Report Generated:2022-10-21 19:25:02
ZONE INFORMATION
01 02 03 04 05 06 07
Zone Name Zone Type HVAC System Name Zone Floor Area (ft2) Avg.Ceiling Height Water Heating System 1 Water Heating System 2
2-nd Floor Conditioned AHU-1.2 (1-st Main
Area)1 1670.6 10 DHW Sys 1 N/A
1-st Floor Conditioned AHU-1.2 (1-st Main
Area)1 2295.9 11 DHW Sys 1 N/A
1-st ADU Conditioned AHU-1.1 (ADU)2 750 11 DHW Sys 1 N/A
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door
Area (ft2)Tilt(deg)
NewNorth Wall 2-nd Floor NewR-29 0 Back 378 166 90
NewEast Wall 2-nd Floor NewR-29 90 Right 406 72.3 90
NewSouth Wall 2-nd Floor NewR-29 180 Front 378 83.9 90
NewWest Wall 2-nd Floor NewR-29 270 Left 406 66.4 90
NewNorth Wall 2 1-st Floor NewR-29 0 Back 850 225.1 90
NewEast Wall 2 1-st Floor NewR-29 90 Right 188 6 90
NewSouth Wall 2 1-st Floor NewR-29 180 Front 410 193.5 90
NewWest Wall 2 1-st Floor NewR-29 270 Left 734 245.9 90
NewNorth Wall 3 1-st ADU NewR-29 0 Back 30 0 90
NewEast Wall 3 1-st ADU NewR-29 90 Right 370 121.5 90
NewSouth Wall 3 1-st ADU NewR-29 180 Front 30 0 90
Wall to Garage 1-st
Floor>>__Garage__NewR-13Wall to Garage n/a n/a 238 0 n/a
Wall to Garage 2 1-st ADU>>__Garage__ NewR-13Wall to Garage n/a n/a 100 0 n/a
Interior Wall 1-st ADU>>1-st Floor Interior R-0 Wall n/a n/a 231 0 n/a
Roof -HP Attic 2 2-nd Floor NewR-38+15 HP Attic n/a n/a 1662.9 n/a n/a
220-P010180856B-000-000-0000000-0000 2022-11-14 16:55:19 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
ProjectName:NewResidence CalculationDate/Time:2022-10-21T19:20:14-07:00 (Page 5 of16)
CalculationDescription:Title 24 Analysis InputFile Name:Title 24 -20713Rodriguess Ave (Rev-5).ribd19x
Registration Number:Registration Date/Time:HERSProvider:
CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version:2019.2.000
Schema Version:rev 20200901
Report Generated:2022-10-21 19:25:02
OPAQUE SURFACES
01 02 03 04 05 06 07 08
Name Zone Construction Azimuth Orientation Gross Area (ft2)Window and Door
Area (ft2)Tilt(deg)
Roof -Attic 1-st Floor NewR-38 Attic n/a n/a 271 n/a n/a
ADU Roof -Attic 1-st ADU NewR-38+15 HP Attic n/a n/a 348.67 n/a n/a
Floor Overhang 2-nd Floor NewR-19 Floor Overhang n/a n/a 81.51 n/a n/a
Raised Floor 1-st Floor NewR-30 Floor Crawlspace n/a n/a 2295.9 n/a n/a
Raised Floor 2 1-st ADU NewR-30 Floor Crawlspace n/a n/a 750 n/a n/a
NewInterior Floor 2-nd Floor Interior R-0 Floor n/a n/a 831.97 n/a n/a
NewInterior Floor 2 2-nd Floor Interior R-0 Floor n/a n/a 401.33 n/a n/a
Floor to Garage 2-nd Floor NewR-19 Floor to Garage n/a n/a 166.28 n/a n/a
NewEast Wall 4 __Garage__NewR-0 Wall (Garage)90 Right 205 34.7 90
NewSouth Wall 4 __Garage__NewR-0 Wall (Garage)180 Front 210 128 90
NewWest Wall 3 __Garage__NewR-0 Wall (Garage)270 Left 27 0 90
OPAQUE SURFACES -CATHEDRAL CEILINGS
01 02 03 04 05 06 07 08 09 10 11
Name Zone Construction Azimuth Orientation Area (ft2)
SkylightArea
(ft2)
RoofRise (x in
12)
Roof
Reflectance RoofEmittance Cool Roof
Roof -HP Attic 2-nd Floor NewR-38+15
HP Attic1 0 Back 7.8 7.7 4 0.1 0.85 No
Roof -Flat Roof 1-st Floor NewR-38 Flat
Roof 0 Back 933.31 23.1 1 0.1 0.85 No
Garage Roof __Garage__NewR-0 Roof
(Garage)0 Back 259.62 0 4 0.1 0.85 No
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type RoofRise (x in12) RoofReflectance RoofEmittance RadiantBarrier Cool Roof
Attic 2-nd Floor Attic Roof2-nd Floor Ventilated 4 0.1 0.85 No No
220-P010180856B-000-000-0000000-0000 2022-11-14 16:55:19 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
ProjectName:NewResidence CalculationDate/Time:2022-10-21T19:20:14-07:00 (Page 6 of16)
CalculationDescription:Title 24 Analysis InputFile Name:Title 24 -20713Rodriguess Ave (Rev-5).ribd19x
Registration Number:Registration Date/Time:HERSProvider:
CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version:2019.2.000
Schema Version:rev 20200901
Report Generated:2022-10-21 19:25:02
ATTIC
01 02 03 04 05 06 07 08
Name Construction Type RoofRise (x in12) RoofReflectance RoofEmittance RadiantBarrier Cool Roof
Attic 1-st Floor Attic Roof1-st Floor Ventilated 4 0.1 0.85 No No
Attic 1-st ADU Attic Roof1-st ADU Ventilated 4 0.1 0.85 No No
FENESTRATION /GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
Window46 Window NewNorth Wall Back 0 1 32.5 0.3 NFRC 0.23 NFRC Bug Screen
Glass Door D5 Window NewNorth Wall Back 0 1 96 0.3 NFRC 0.23 NFRC Bug Screen
Window49 Window NewNorth Wall Back 0 1 32.5 0.3 NFRC 0.23 NFRC Bug Screen
Window51 Window NewNorth Wall Back 0 1 5 0.3 NFRC 0.23 NFRC Bug Screen
Window50 Window NewEast Wall Right 90 1 5 0.3 NFRC 0.23 NFRC Bug Screen
Window52 Window NewEast Wall Right 90 1 5 0.3 NFRC 0.23 NFRC Bug Screen
Window53 Window NewEast Wall Right 90 1 5 0.3 NFRC 0.23 NFRC Bug Screen
Window54 Window NewEast Wall Right 90 1 6 0.3 NFRC 0.23 NFRC Bug Screen
Window55 Window NewEast Wall Right 90 1 32.5 0.3 NFRC 0.23 NFRC Bug Screen
Window56 Window NewEast Wall Right 90 1 12.5 0.3 NFRC 0.23 NFRC Bug Screen
Window57 Window NewEast Wall Right 90 1 6.3 0.3 NFRC 0.23 NFRC Bug Screen
Window58 Window NewSouth Wall Front 180 1 6.3 0.3 NFRC 0.23 NFRC Bug Screen
Window59 Window NewSouth Wall Front 180 1 8.3 0.3 NFRC 0.23 NFRC Bug Screen
Window60 Window NewSouth Wall Front 180 1 32.5 0.3 NFRC 0.23 NFRC Bug Screen
Window41 Window NewSouth Wall Front 180 1 13.8 0.3 NFRC 0.23 NFRC Bug Screen
Window42 Window NewSouth Wall Front 180 1 18 0.3 NFRC 0.23 NFRC Bug Screen
Window43 Window NewSouth Wall Front 180 1 5 0.3 NFRC 0.23 NFRC Bug Screen
Window40 Window NewWest Wall Left 270 1 13.8 0.3 NFRC 0.23 NFRC Bug Screen
Window44 Window NewWest Wall Left 270 1 11.3 0.3 NFRC 0.23 NFRC Bug Screen
220-P010180856B-000-000-0000000-0000 2022-11-14 16:55:19 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
ProjectName:NewResidence CalculationDate/Time:2022-10-21T19:20:14-07:00 (Page 7 of16)
CalculationDescription:Title 24 Analysis InputFile Name:Title 24 -20713Rodriguess Ave (Rev-5).ribd19x
Registration Number:Registration Date/Time:HERSProvider:
CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version:2019.2.000
Schema Version:rev 20200901
Report Generated:2022-10-21 19:25:02
FENESTRATION /GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
Window45 Window NewWest Wall Left 270 1 11.3 0.3 NFRC 0.23 NFRC Bug Screen
Window47 Window NewWest Wall Left 270 1 15 0.3 NFRC 0.23 NFRC Bug Screen
Window48 Window NewWest Wall Left 270 1 15 0.3 NFRC 0.23 NFRC Bug Screen
Glass Door D2 Window NewNorth Wall 2 Back 0 1 108 0.3 NFRC 0.23 NFRC Bug Screen
Window14 Window NewNorth Wall 2 Back 0 1 27 0.3 NFRC 0.23 NFRC Bug Screen
Window15 Window NewNorth Wall 2 Back 0 1 12 0.3 NFRC 0.23 NFRC Bug Screen
Window18 Window NewNorth Wall 2 Back 0 1 32.5 0.3 NFRC 0.23 NFRC Bug Screen
Window19 Window NewNorth Wall 2 Back 0 1 13 0.3 NFRC 0.23 NFRC Bug Screen
Window24 Window NewNorth Wall 2 Back 0 1 11.3 0.3 NFRC 0.23 NFRC Bug Screen
Window25 Window NewNorth Wall 2 Back 0 1 5 0.3 NFRC 0.23 NFRC Bug Screen
Window26 Window NewNorth Wall 2 Back 0 1 11.3 0.3 NFRC 0.23 NFRC Bug Screen
Window27 Window NewNorth Wall 2 Back 0 1 5 0.3 NFRC 0.23 NFRC Bug Screen
Window28 Window NewEast Wall 2 Right 90 1 6 0.3 NFRC 0.23 NFRC Bug Screen
Window33 Window NewSouth Wall 2 Front 180 1 39 0.3 NFRC 0.23 NFRC Bug Screen
Window34 Window NewSouth Wall 2 Front 180 1 13 0.3 NFRC 0.23 NFRC Bug Screen
Window1 Window NewSouth Wall 2 Front 180 1 17 0.3 NFRC 0.23 NFRC Bug Screen
Window2 Window NewSouth Wall 2 Front 180 1 51 0.3 NFRC 0.23 NFRC Bug Screen
Window3 Window NewSouth Wall 2 Front 180 1 25.5 0.3 NFRC 0.23 NFRC Bug Screen
Window16 Window NewWest Wall 2 Left 270 1 8 0.3 NFRC 0.23 NFRC Bug Screen
Window17 Window NewWest Wall 2 Left 270 1 2.7 0.3 NFRC 0.23 NFRC Bug Screen
Window20 Window NewWest Wall 2 Left 270 1 11.3 0.3 NFRC 0.23 NFRC Bug Screen
Window21 Window NewWest Wall 2 Left 270 1 5 0.3 NFRC 0.23 NFRC Bug Screen
Window22 Window NewWest Wall 2 Left 270 1 32.5 0.3 NFRC 0.23 NFRC Bug Screen
Window23 Window NewWest Wall 2 Left 270 1 13 0.3 NFRC 0.23 NFRC Bug Screen
Window4 Window NewWest Wall 2 Left 270 1 32 0.3 NFRC 0.23 NFRC Bug Screen
220-P010180856B-000-000-0000000-0000 2022-11-14 16:55:19 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
ProjectName:NewResidence CalculationDate/Time:2022-10-21T19:20:14-07:00 (Page 8 of16)
CalculationDescription:Title 24 Analysis InputFile Name:Title 24 -20713Rodriguess Ave (Rev-5).ribd19x
Registration Number:Registration Date/Time:HERSProvider:
CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version:2019.2.000
Schema Version:rev 20200901
Report Generated:2022-10-21 19:25:02
FENESTRATION /GLAZING
01 02 03 04 05 06 07 08 09 10 11 12 13 14
Name Type Surface Orientation Azimuth Width
(ft)
Height
(ft)Mult.Area
(ft2)U-factor U-factor
Source SHGC
SHGC
Sourc
e
Exterior
Shading
Window5 Window NewWest Wall 2 Left 270 1 16 0.3 NFRC 0.23 NFRC Bug Screen
Window6 Window NewWest Wall 2 Left 270 1 51 0.3 NFRC 0.23 NFRC Bug Screen
Window7 Window NewWest Wall 2 Left 270 1 25.5 0.3 NFRC 0.23 NFRC Bug Screen
Window8 Window NewWest Wall 2 Left 270 1 11.3 0.3 NFRC 0.23 NFRC Bug Screen
Window9 Window NewWest Wall 2 Left 270 1 5 0.3 NFRC 0.23 NFRC Bug Screen
Window10 Window NewWest Wall 2 Left 270 1 11.3 0.3 NFRC 0.23 NFRC Bug Screen
Window11 Window NewWest Wall 2 Left 270 1 5 0.3 NFRC 0.23 NFRC Bug Screen
Window12 Window NewWest Wall 2 Left 270 1 11.3 0.3 NFRC 0.23 NFRC Bug Screen
Window13 Window NewWest Wall 2 Left 270 1 5 0.3 NFRC 0.23 NFRC Bug Screen
Window29 Window NewEast Wall 3 Right 90 1 32.5 0.3 NFRC 0.23 NFRC Bug Screen
Window30 Window NewEast Wall 3 Right 90 1 32.5 0.3 NFRC 0.23 NFRC Bug Screen
Window31 Window NewEast Wall 3 Right 90 1 32.5 0.3 NFRC 0.23 NFRC Bug Screen
Window32 Window NewEast Wall 4 Right 90 1 12 0.3 NFRC 0.23 NFRC Bug Screen
Skylight S4 Skylight Roof -HP Attic Back 0 1 7.7 0.53 NFRC 0.24 NFRC None
Skylight S1 Skylight Roof -Flat Roof Back 0 1 7.7 0.53 NFRC 0.24 NFRC None
Skylight S2 Skylight Roof -Flat Roof Back 0 1 7.7 0.53 NFRC 0.24 NFRC None
Skylight S3 Skylight Roof -Flat Roof Back 0 1 7.7 0.53 NFRC 0.24 NFRC None
OPAQUE DOORS
01 02 03 04
Name Side ofBuilding Area (ft2)U-factor
Door D1 NewSouth Wall 2 48 0.5
Door D3 NewEast Wall 3 24 0.5
Door D4 NewEast Wall 4 22.7 0.5
Garage Door NewSouth Wall 4 128 0.7
220-P010180856B-000-000-0000000-0000 2022-11-14 16:55:19 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
ProjectName:NewResidence CalculationDate/Time:2022-10-21T19:20:14-07:00 (Page 9 of16)
CalculationDescription:Title 24 Analysis InputFile Name:Title 24 -20713Rodriguess Ave (Rev-5).ribd19x
Registration Number:Registration Date/Time:HERSProvider:
CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version:2019.2.000
Schema Version:rev 20200901
Report Generated:2022-10-21 19:25:02
SLAB FLOORS
01 02 03 04 05 06 07 08
Name Zone Area (ft2)Perimeter (ft)Edge Insul.R-value
and Depth
Edge Insul.R-value
and Depth Carpeted Fraction Heated
GarageSlab __Garage__425.9 89 none 0 0%No
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
ConstructionName Surface Type ConstructionType Framing Total Cavity
R-value
Interior /Exterior
Continuous
R-value
U-factor AssemblyLayers
NewR-0 Wall (Garage) Exterior Walls Wood Framed Wall 2x4 @ 16 in.O.C. R-0 None /None 0.361
Inside Finish:Gypsum Board
Cavity /Frame:no insul./2x4
Exterior Finish:3Coat Stucco
NewR-29 Exterior Walls Wood Framed Wall 2x4 @ 16 in.O.C. R-0 R-29 /None 0.031
Inside Finish:Gypsum Board
Sheathing /Insulation:R-29 Sheathing
Cavity /Frame:no insul./2x4
Exterior Finish:3Coat Stucco
NewR-0 Roof (Garage) Cathedral Ceilings Wood Framed
Ceiling 2x4 @ 16 in.O.C. R-0 None /None 0.484
Roofing:Light Roof (Asphalt Shingle)
Roof Deck:Wood
Siding/sheathing/decking
Cavity /Frame:no insul./2x4
Inside Finish:Gypsum Board
NewR-38+15 HP Attic1 Cathedral Ceilings Wood Framed
Ceiling 2x4 @ 24 in.O.C. R-38 R-15 /None 0.02
Roofing:Light Roof (Asphalt Shingle)
Roof Deck:Wood
Siding/sheathing/decking
Cavity /Frame:R-38 /2x4
Sheathing /Insulation:R-15 Sheathing
Inside Finish:Gypsum Board
220-P010180856B-000-000-0000000-0000 2022-11-14 16:55:19 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
ProjectName:NewResidence CalculationDate/Time:2022-10-21T19:20:14-07:00 (Page 10 of16)
CalculationDescription:Title 24 Analysis InputFile Name:Title 24 -20713Rodriguess Ave (Rev-5).ribd19x
Registration Number:Registration Date/Time:HERSProvider:
CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version:2019.2.000
Schema Version:rev 20200901
Report Generated:2022-10-21 19:25:02
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
ConstructionName Surface Type ConstructionType Framing Total Cavity
R-value
Interior /Exterior
Continuous
R-value
U-factor AssemblyLayers
NewR-38 Flat Roof Cathedral Ceilings Wood Framed
Ceiling 2x12 @ 16 in.O.C. R-38 None /None 0.03
Roofing:Light Roof (Asphalt Shingle)
Roof Deck:Wood
Siding/sheathing/decking
Cavity /Frame:R-38 /2x12
Inside Finish:Gypsum Board
NewR-13Wall to
Garage Interior Walls Wood Framed Wall 2x4 @ 16 in.O.C. R-13 None /None 0.092
Inside Finish:Gypsum Board
Cavity /Frame:R-13/2x4
Other Side Finish:Gypsum Board
Interior R-0 Wall Interior Walls Wood Framed Wall 2x4 @ 16 in.O.C. R-0 None /None 0.277
Inside Finish:Gypsum Board
Cavity /Frame:no insul./2x4
Other Side Finish:Gypsum Board
Attic Roof2-nd Floor Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in.O.C. R-15 None /None 0.07
Roofing:Light Roof (Asphalt Shingle)
Roof Deck:Wood
Siding/sheathing/decking
Cavity /Frame:R-13.0 /2x4
Around Roof Joists:R-2.0 insul.
Attic Roof1-st Floor Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in.O.C. R-0 None /None 0.644
Roofing:Light Roof (Asphalt Shingle)
Roof Deck:Wood
Siding/sheathing/decking
Cavity /Frame:no insul./2x4
Attic Roof1-st ADU Attic Roofs Wood Framed
Ceiling 2x4 @ 24 in.O.C. R-15 None /None 0.07
Roofing:Light Roof (Asphalt Shingle)
Roof Deck:Wood
Siding/sheathing/decking
Cavity /Frame:R-13.0 /2x4
Around Roof Joists:R-2.0 insul.
NewR-30 Floor
Crawlspace
Floors Over
Crawlspace Wood Framed Floor 2x10 @ 16 in.O.C. R-30 None /None 0.034
Floor Surface:Carpeted
Floor Deck:Wood
Siding/sheathing/decking
Cavity /Frame:R-30 /2x10
220-P010180856B-000-000-0000000-0000 2022-11-14 16:55:19 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
ProjectName:NewResidence CalculationDate/Time:2022-10-21T19:20:14-07:00 (Page 11 of16)
CalculationDescription:Title 24 Analysis InputFile Name:Title 24 -20713Rodriguess Ave (Rev-5).ribd19x
Registration Number:Registration Date/Time:HERSProvider:
CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version:2019.2.000
Schema Version:rev 20200901
Report Generated:2022-10-21 19:25:02
OPAQUE SURFACE CONSTRUCTIONS
01 02 03 04 05 06 07 08
ConstructionName Surface Type ConstructionType Framing Total Cavity
R-value
Interior /Exterior
Continuous
R-value
U-factor AssemblyLayers
NewR-38+15 HP Attic Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in.O.C. R-38 None /None 0.025
Over Ceiling Joists:R-28.9 insul.
Cavity /Frame:R-9.1 /2x4
Inside Finish:Gypsum Board
NewR-38 Attic Ceilings (below
attic)
Wood Framed
Ceiling 2x4 @ 24 in.O.C. R-38 None /None 0.025
Over Ceiling Joists:R-28.9 insul.
Cavity /Frame:R-9.1 /2x4
Inside Finish:Gypsum Board
NewR-19 Floor
Overhang Exterior Floors Wood Framed Floor 2x6 @ 16 in.O.C. R-19 None /None 0.052
Floor Surface:Carpeted
Floor Deck:Wood
Siding/sheathing/decking
Cavity /Frame:R-19 in 5-1/2 in.(R-18)/
2x6
Interior R-0 Floor Interior Floors Wood Framed Floor 2x12 @ 16 in.O.C. R-0 None /None 0.196
Floor Surface:Carpeted
Floor Deck:Wood
Siding/sheathing/decking
Cavity /Frame:no insul./2x12
Ceiling BelowFinish:Gypsum Board
NewR-19 Floor to
Garage Interior Floors Wood Framed Floor 2x6 @ 16 in.O.C. R-19 None /None 0.049
Floor Surface:Carpeted
Floor Deck:Wood
Siding/sheathing/decking
Cavity /Frame:R-19 in 5-1/2 in.(R-18)/
2x6
Ceiling BelowFinish:Gypsum Board
BUILDING ENVELOPE -HERS VERIFICATION
01 02 03 04
QualityInsulationInstallation(QII)HighR-value Spray Foam Insulation Building Envelope Air Leakage CFM50
Required Not Required Not Required n/a
220-P010180856B-000-000-0000000-0000 2022-11-14 16:55:19 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
ProjectName:NewResidence CalculationDate/Time:2022-10-21T19:20:14-07:00 (Page 12 of16)
CalculationDescription:Title 24 Analysis InputFile Name:Title 24 -20713Rodriguess Ave (Rev-5).ribd19x
Registration Number:Registration Date/Time:HERSProvider:
CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version:2019.2.000
Schema Version:rev 20200901
Report Generated:2022-10-21 19:25:02
WATER HEATING SYSTEMS
01 02 03 04 05 06 07
Name System Type DistributionType Water Heater Name (#)Solar Heating System CompactDistribution HERS Verification
DHW Sys 1 Domestic Hot Water
(DHW)
Standard Distribution
System
DHW Heater 1 (1)
DHW Heater 1-2 (1)n/a None n/a
WATER HEATERS
01 02 03 04 05 06 07 08 09 10 11 12
Name
Heating
Element
Type
Tank Type #of
Units
Tank
Vol.
(gal)
Energy
Factor or
Efficiency
InputRating
or Pilot
Tank
Insulation
R-value
(Int/Ext)
Standby Loss
or Recovery
Eff
1stHr.Rating
or Flow Rate
NEEA HeatPump
Brand or Model
Tank Locationor
AmbientCondition
DHW Heater 1 Heat Pump n/a 1 50 NEEA Rated <=12 kW n/a n/a n/a A.O.Smith\HPTU
50N 120 (50 gal)Garage
DHW Heater 1-2 Gas Consumer
Instantaneous 1 0 0.96-UEF <=200
kBtu/hr 0 n/a n/a n/a n/a
WATER HEATING -HERS VERIFICATION
01 02 03 04 05 06 07 08
Name Pipe Insulation Parallel Piping CompactDistribution CompactDistribution
Type RecirculationControl Central DHW
Distribution
Shower DrainWater
HeatRecovery
DHW Sys 1 -1/1 Not Required Not Required Not Required None Not Required Not Required Not Required
DHW Sys 1 -2/1 Not Required Not Required Not Required None Not Required Not Required Not Required
220-P010180856B-000-000-0000000-0000 2022-11-14 16:55:19 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
ProjectName:NewResidence CalculationDate/Time:2022-10-21T19:20:14-07:00 (Page 13 of16)
CalculationDescription:Title 24 Analysis InputFile Name:Title 24 -20713Rodriguess Ave (Rev-5).ribd19x
Registration Number:Registration Date/Time:HERSProvider:
CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version:2019.2.000
Schema Version:rev 20200901
Report Generated:2022-10-21 19:25:02
SPACE CONDITIONING SYSTEMS
01 02 03 04 05 06 07 08 09 10 11
Name System Type Heating Unit
Name
Cooling Unit
Name FanName Distribution
Name
Required
Thermostat
Type
Status
Verified
Existing
Condition
Heating
Equipment
Count
Cooling
Equipment
Count
AHU-1.2 (1-st Main Area)1 Heat pump heating cooling Heat Pump
System 1
Heat Pump
System 1 HVAC Fan 1
Air
Distribution
System 1
Setback New NA 1 1
AHU-1.1 (ADU)2 Heat pump heating cooling Heat Pump
System 2
Heat Pump
System 2 HVAC Fan 2
Air
Distribution
System 2
Setback New NA 1 1
01 02 03 04 05 06 07 08 09 10 11
HVAC -HEAT PUMPS
Name System Type Number ofUnits
Heating Cooling Zonally
Controlled
Compressor
Type HERS Verification
HSPF/COP Cap 47 Cap 17 SEER EER/CEER
Heat Pump System 1 Central split HP 1 9 60000 48000 16 12.5 Not Zonal Single
Speed
Heat Pump System
1-hers-htpump
Heat Pump System 2 Central split HP 1 10 24000 18000 16 13 Not Zonal Single
Speed
Heat Pump System
2-hers-htpump
HVAC HEAT PUMPS -HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name Verified Airflow Airflow Target Verified EER Verified SEER Verified Refrigerant
Charge Verified HSPF Verified Heating
Cap 47
Verified Heating
Cap 17
Heat Pump System
1-hers-htpump Required 350 Required Required Yes Yes Yes Yes
Heat Pump System
2-hers-htpump Required 350 Required Required Yes Yes Yes Yes
220-P010180856B-000-000-0000000-0000 2022-11-14 16:55:19 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
ProjectName:NewResidence CalculationDate/Time:2022-10-21T19:20:14-07:00 (Page 14 of16)
CalculationDescription:Title 24 Analysis InputFile Name:Title 24 -20713Rodriguess Ave (Rev-5).ribd19x
Registration Number:Registration Date/Time:HERSProvider:
CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version:2019.2.000
Schema Version:rev 20200901
Report Generated:2022-10-21 19:25:02
HVAC -DISTRIBUTION SYSTEMS
01 02 03 04 05 06 07 08 09 10 11 12
DuctIns.R-value DuctLocation Surface Area
Name Type DesignType Supply Return Supply Return Supply Return Bypass
Duct DuctLeakage HERS
Verification
Air Distribution
System 1 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a
No
Bypass
Duct
Sealed and
Tested
Air
Distribution
System
1-hers-dist
Air Distribution
System 2 Unconditioned attic Non-Verified R-8 R-8 Attic Attic n/a n/a
No
Bypass
Duct
Sealed and
Tested
Air
Distribution
System
2-hers-dist
HVAC DISTRIBUTION -HERS VERIFICATION
01 02 03 04 05 06 07 08 09
Name DuctLeakage
Verification
DuctLeakage
Target(%)
Verified Duct
Location
Verified Duct
Design Buried Ducts DeeplyBuried
Ducts
Low-leakage Air
Handler
Low Leakage
Ducts Entirely in
Conditioned
Space
Air Distribution
System 1-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No
Air Distribution
System 2-hers-dist Yes 5.0 Not Required Not Required Not Required Credit not taken Not Required No
HVAC -FAN SYSTEMS
01 02 03 04
Name Type FanPower (Watts/CFM)Name
HVAC Fan 1 HVAC Fan 0.45 HVAC Fan 1-hers-fan
HVAC Fan 2 HVAC Fan 0.45 HVAC Fan 2-hers-fan
220-P010180856B-000-000-0000000-0000 2022-11-14 16:55:19 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
ProjectName:NewResidence CalculationDate/Time:2022-10-21T19:20:14-07:00 (Page 15 of16)
CalculationDescription:Title 24 Analysis InputFile Name:Title 24 -20713Rodriguess Ave (Rev-5).ribd19x
Registration Number:Registration Date/Time:HERSProvider:
CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version:2019.2.000
Schema Version:rev 20200901
Report Generated:2022-10-21 19:25:02
HVAC FAN SYSTEMS -HERS VERIFICATION
01 02 03
Name Verified FanWattDraw Required FanEfficacy(Watts/CFM)
HVAC Fan 1-hers-fan Required 0.45
HVAC Fan 2-hers-fan Required 0.45
IAQ (INDOOR AIR QUALITY)FANS
01 02 03 04 05 06 07
Dwelling Unit IAQ CFM IAQ Watts/CFM IAQ FanType IAQ Recovery
Effectiveness -SRE
IAQ Recovery
Effectiveness -ASRE HERS Verification
SFam IAQVentRpt 1-1 100 0.1 Exhaust n/a n/a Yes
SFam IAQVentRpt 2-1 100 0.1 Exhaust n/a n/a Yes
SFam ADU IAQVentRpt
3-1 40 0.1 Exhaust n/a n/a Yes
220-P010180856B-000-000-0000000-0000 2022-11-14 16:55:19 CalCERTS inc.
CERTIFICATE OF COMPLIANCE CF1R-PRF-01E
ProjectName:NewResidence CalculationDate/Time:2022-10-21T19:20:14-07:00 (Page 16 of16)
CalculationDescription:Title 24 Analysis InputFile Name:Title 24 -20713Rodriguess Ave (Rev-5).ribd19x
Registration Number:Registration Date/Time:HERSProvider:
CA Building Energy Efficiency Standards -2019 Residential Compliance Report Version:2019.2.000
Schema Version:rev 20200901
Report Generated:2022-10-21 19:25:02
DOCUMENTATION AUTHOR'S DECLARATION STATEMENT
1.I certify that this Certificate of Compliance documentation is accurate and complete.
Documentation Author Name:Documentation Author Signature:
Company:Signature Date:
Address:CEA/HERSCertification Identification (If applicable):
City/State/Zip:Phone:
RESPONSIBLE PERSON'S DECLARATION STATEMENT
I certify the following under penalty of perjury, under the laws of the State of California:
1. I am eligible under Division 3of the Business and Professions Code to accept responsibility for the building design identified on this Certificate of Compliance.
2. I certify that the energy features and performance specifications identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the California Code of Regulations.
3. The building design features or system design features identified on this Certificate of Compliance are consistent with the information provided on other applicable compliance documents, worksheets,
calculations, plans and specifications submitted to the enforcement agency for approval with this building permit application.
Responsible Designer Name:Responsible Designer Signature:
Company:Date Signed:
Address:License:
City/State/Zip:Phone:
Easy to Verify
at CalCERTS.com
Radik Musin
MECONE Inc.
PO Box 1301
Murrieta, CA 92564
2022-10-21 19:29:13
M37352
951-445-7213
Tracy Hsu
Homeowner - Installer
22330 Santa Paula Ave
Cupertino, CA 95014
2022-11-14 16:55:19
N/A
408-464-5030
Digitally signed by CalCERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies
Registration Provider responsibility for the accuracy of the information.
220-P010180856B-000-000-0000000-0000 2022-11-14 16:55:19 CalCERTS inc.
RESIDENTIAL MEASURES SUMMARY RMS-1
Project Name Building Type Single Family Addition Alone Date
Multi Family Existing+ Addition/Alteration
Project Address California Energy Climate Zone Total Cond. Floor Area Addition # of Units
INSULATION Area
Construction Type Cavity (ft2) Special Features Status
FENESTRATION Total Area: Glazing Percentage: New/Altered Average U-Factor:
Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R-Value Status
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
New Residence
20713 Rodrigues Ave Cupertino
Wood Framed Attic
10/21/2022
4
CA Climate Zone 04 4,717 1
Wood Framed w/Crawl Space
Wall
Demising
Demising
Floor
Roof
Door
Wood Framed
Wood Framed w/o Crawl Space
Wood Framed w/o Crawl Space
Opaque Door
2,999
1,233
166
82
2,012
72
R 19
- no insulation -
- no insulation -
R 19
R 38
- no insulation -
New
New
New
New
New
New
Add=R-29.0
Add=R-15.0
n/a
Rear (N)
Rear (N)
Right (E)
Front (S)
Left (W)
Skylight
187.1
204.0
175.8
229.4
312.3
30.8 0.530
0.300
0.300
0.300
0.300
0.300
0.24
0.23
0.23
0.23
0.23
0.23
none
none
none
none
none
none
none
none
none
none
none
none
N/A
N/A
N/A
N/A
N/A
N/A
New
New
New
New
New
New
16.0 SEER 1
1
Split Heat Pump
Split Heat Pump
Split Heat Pump
Split Heat Pump
9.00 HSPF
10.00 HSPF
New
New16.0 SEER
Setback
Setback
Attic AHU-1.2 (1-st Main Area)
AHU-1.1 (ADU)
Ducted
Ducted
Ducted
Ducted
New
NewAttic
8.0
8.0
0.96
Standard 1
1
Heat Pump
Small Instantaneous Gas
2.90 50
0 Standard
New
New
ID: 200924 Page 19 of 24EnergyPro 8.3 by EnergySoft SoftwareUser Number: 9963
Wood Framed w/Crawl Space Floor
Roof Wood Framed Rafter
3,046
910
R 30
R 38
New
New
1,139 24.2% 0.31
RESIDENTIAL MEASURES SUMMARY RMS-1
Project Name Building Type Single Family Addition Alone Date
Multi Family Existing+ Addition/Alteration
Project Address California Energy Climate Zone Total Cond. Floor Area Addition # of Units
INSULATION Area
Construction Type Cavity (ft2) Special Features Status
FENESTRATION Total Area: Glazing Percentage: New/Altered Average U-Factor:
Orientation Area(ft2) U-Fac SHGC Overhang Sidefins Exterior Shades Status
HVAC SYSTEMS
Qty. Heating Min. Eff Cooling Min. Eff Thermostat Status
HVAC DISTRIBUTION Duct
Location Heating Cooling Duct Location R-Value Status
WATER HEATING
Qty. Type Gallons Min. Eff Distribution Status
New Residence
20713 Rodrigues Ave Cupertino
10/21/2022
4
CA Climate Zone 04 4,717 1
Wood Framed
Roof
Demising
Demising
Wood Framed Attic
Wood Framed
271
338
231
R 38
R 13
- no insulation -
New
New
New
n/a
ID: 200924 Page 20 of 24EnergyPro 8.3 by EnergySoft SoftwareUser Number: 9963
1,139 24.2% 0.31
2019 Low-Rise Residential Mandatory Measures Summary
NOTE: Low-rise residential buildings subject to the Energy Standards must comply with all applicable mandatory measures, regardless of the compliance approach
used. Review the respective section for more information. *Exceptions may apply.
(01/2020)
Building Envelope Measures:
§ 110.6(a)1:
Air Leakage. Manufactured fenestration, exterior doors, and exterior pet doors must limit air leakage to 0.3 CFM per square foot or less
when tested per NFRC-400, ASTM E283 or AAMA/WDMA/CSA 101/I.S.2/A440-2011.*
§ 110.6(a)5: Labeling. Fenestration products and exterior doors must have a label meeting the requirements of § 10-111(a).
§ 110.6(b):
Field fabricated exterior doors and fenestration products must use U-factors and solar heat gain coefficient (SHGC) values from Tables
110.6-A, 110.6-B, or JA4.5 for exterior doors. They must be caulked and/or weather-stripped.*
§ 110.7:
Air Leakage. All joints, penetrations, and other openings in the building envelope that are potential sources of air leakage must be caulked,
gasketed, or weather stripped.
§ 110.8(a):Insulation Certification by Manufacturers. Insulation must be certified by the Department of Consumer Affairs, Bureau of Household Goods
and Services (BHGS).
§ 110.8(g): Insulation Requirements for Heated Slab Floors. Heated slab floors must be insulated per the requirements of § 110.8(g).
§ 110.8(i):
Roofing Products Solar Reflectance and Thermal Emittance. The thermal emittance and aged solar reflectance values of the roofing
material must meet the requirements of § 110.8(i) and be labeled per §10-113 when the installation of a cool roof is specified on the CF1R.
§ 110.8(j): Radiant Barrier. When required, radiant barriers must have an emittance of 0.05 or less and be certified to the Department of Consumer Affairs.
§ 150.0(a):
Ceiling and Rafter Roof Insulation. Minimum R-22 insulation in wood-frame ceiling; or the weighted average U-factor must not exceed 0.043.
Minimum R-19 or weighted average U-factor of 0.054 or less in a rafter roof alteration. Attic access doors must have permanently attached
insulation using adhesive or mechanical fasteners. The attic access must be gasketed to prevent air leakage. Insulation must be installed in
direct contact with a continuous roof or ceiling which is sealed to limit infiltration and exfiltration as specified in § 110.7, including but not limited
to placing insulation either above or below the roof deck or on top of a drywall ceiling.*
§ 150.0(b): Loose-fill Insulation. Loose fill insulation must meet the manufacturer’s required density for the labeled R-value.
§ 150.0(c):
Wall Insulation. Minimum R-13 insulation in 2x4 inch wood framing wall or have a U-factor of 0.102 or less, or R-20 in 2x6 inch wood framing or
have a U-factor of 0.071 or less. Opaque non-framed assemblies must have an overall assembly U-factor not exceeding 0.102. Masonry walls
must meet Tables 150.1-A or B.*
§ 150.0(d): Raised-floor Insulation. Minimum R-19 insulation in raised wood framed floor or 0.037 maximum U-factor.*
§ 150.0(f):
Slab Edge Insulation. Slab edge insulation must meet all of the following: have a water absorption rate, for the insulation material alone without
facings, no greater than 0.3 percent; have a water vapor permeance no greater than 2.0 perm per inch; be protected from physical damage and
UV light deterioration; and, when installed as part of a heated slab floor, meet the requirements of § 110.8(g).
§ 150.0(g)1:
Vapor Retarder. In climate zones 1 through 16, the earth floor of unvented crawl space must be covered with a Class I or Class II vapor
retarder. This requirement also applies to controlled ventilation crawl space for buildings complying with the exception to § 150.0(d).
§ 150.0(g)2:
Vapor Retarder. In climate zones 14 and 16, a Class I or Class II vapor retarder must be installed on the conditioned space side of all
insulation in all exterior walls, vented attics, and unvented attics with air-permeable insulation.
§ 150.0(q):
Fenestration Products. Fenestration, including skylights, separating conditioned space from unconditioned space or outdoors must have a
maximum U-factor of 0.58; or the weighted average U-factor of all fenestration must not exceed 0.58.*
Fireplaces, Decorative Gas Appliances, and Gas Log Measures:
§ 110.5(e) Pilot Light. Continuously burning pilot lights are not allowed for indoor and outdoor fireplaces.
§ 150.0(e)1: Closable Doors. Masonry or factory-built fireplaces must have a closable metal or glass door covering the entire opening of the firebox.
§ 150.0(e)2:
Combustion Intake. Masonry or factory-built fireplaces must have a combustion outside air intake, which is at least six square inches in area
and is equipped with a readily accessible, operable, and tight-fitting damper or combustion-air control device.*
§ 150.0(e)3: Flue Damper. Masonry or factory-built fireplaces must have a flue damper with a readily accessible control.*
Space Conditioning, Water Heating, and Plumbing System Measures:
§ 110.0-§ 110.3:
Certification. Heating, ventilation and air conditioning (HVAC) equipment, water heaters, showerheads, faucets, and all other regulated
appliances must be certified by the manufacturer to the California Energy Commission.*
§ 110.2(a): HVAC Efficiency. Equipment must meet the applicable efficiency requirements in Table 110.2-A through Table 110.2-K.*
§ 110.2(b):
Controls for Heat Pumps with Supplementary Electric Resistance Heaters. Heat pumps with supplementary electric resistance heaters
must have controls that prevent supplementary heater operation when the heating load can be met by the heat pump alone; and in which the
cut-on temperature for compression heating is higher than the cut-on temperature for supplementary heating, and the cut-off temperature for
compression heating is higher than the cut-off temperature for supplementary heating.*
§ 110.2(c):
Thermostats. All heating or cooling systems not controlled by a central energy management control system (EMCS) must have a
setback thermostat.*
§ 110.3(c)4:
Water Heating Recirculation Loops Serving Multiple Dwelling Units. Water heating recirculation loops serving multiple dwelling units must
meet the air release valve, backflow prevention, pump priming, pump isolation valve, and recirculation loop connection requirements of
§ 110.3(c)4.
§ 110.3(c)6:
Isolation Valves. Instantaneous water heaters with an input rating greater than 6.8 kBtu per hour (2 kW) must have isolation valves with hose
bibbs or other fittings on both cold and hot water lines to allow for flushing the water heater when the valves are closed.
§ 110.5:
Pilot Lights. Continuously burning pilot lights are prohibited for natural gas: fan-type central furnaces; household cooking appliances (except
appliances without an electrical supply voltage connection with pilot lights that consume less than 150 Btu per hour ); and pool and spa heaters.*
§ 150.0(h)1:
Building Cooling and Heating Loads. Heating and/or cooling loads are calculated in accordance with the ASHRAE Handbook,
Equipment Volume, Applications Volume, and Fundamentals Volume; the SMACNA Residential Comfort System Installation Standards
Manual; or the ACCA Manual J using design conditions specified in § 150.0(h)2.
2019 Low-Rise Residential Mandatory Measures Summary
§ 150.0(h)3A: Clearances. Air conditioner and heat pump outdoor condensing units must have a clearance of at least five feet from the outlet of any dryer
t
§ 150.0(h)3B:
Liquid Line Drier. Air conditioners and heat pump systems must be equipped with liquid line filter driers if required, as specified by the
manufacturer’s instructions.
§ 150.0(j)1:
Storage Tank Insulation. Unfired hot water tanks, such as storage tanks and backup storage tanks for solar water-heating systems, must have
a minimum of R-12 external insulation or R-16 internal insulation where the internal insulation R-value is indicated on the exterior of the tank.
§ 150.0(j)2A:
Water Piping, Solar Water-heating System Piping, and Space Conditioning System Line Insulation. All domestic hot water piping must
be insulated as specified in Section 609.11 of the California Plumbing Code. In addition, the following piping conditions must have a minimum
insulation wall thickness of one inch or a minimum insulation R-value of 7.7: the first five feet of cold water pipes from the storage tank; all hot
water piping with a nominal diameter equal to or greater than 3/4 inch and less than one inch; all hot water piping with a nominal diameter less
than 3/4 inch that is: associated with a domestic hot water recirculation system, from the heating source to storage tank or between tanks,
buried below grade, and from the heating source to kitchen fixtures.*
§ 150.0(j)3:
Insulation Protection. Piping insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance, and
wind as required by Section 120.3(b). Insulation exposed to weather must be water retardant and protected from UV light (no adhesive tapes).
Insulation covering chilled water piping and refrigerant suction piping located outside the conditioned space must include, or be protected by, a
Class I or Class II vapor retarder. Pipe insulation buried below grade must be installed in a waterproof and non-crushable casing or sleeve.
§ 150.0(n)1:
Gas or Propane Water Heating Systems. Systems using gas or propane water heaters to serve individual dwelling units must include all of
the following: A dedicated 125 volt, 20 amp electrical receptacle connected to the electric panel with a 120/240 volt 3 conductor, 10 AWG
copper branch circuit, within three feet of the water heater without obstruction. Both ends of the unused conductor must be labeled with the
word “spare” and be electrically isolated. Have a reserved single pole circuit breaker space in the electrical panel adjacent to the circuit breaker
for the branch circuit and labeled with the words “Future 240V Use”; a Category III or IV vent, or a Type B vent with straight pipe between the
outside termination and the space where the water heater is installed; a condensate drain that is no more than two inches higher than the base
of the water heater, and allows natural draining without pump assistance; and a gas supply line with a capacity of at least 2 00,000 Btu per hour.
§ 150.0(n)2: Recirculating Loops. Recirculating loops serving multiple dwelling units must meet the requirements of § 110.3(c)5.
§ 150.0(n)3:
Solar Water-heating Systems. Solar water-heating systems and collectors must be certified and rated by the Solar Rating and Certification
Corporation (SRCC), the International Association of Plumbing and Mechanical Officials, Research and Testing (IAPMO R&T), or by a listing
agency that is approved by the Executive Director.
Ducts and Fans Measures:
§ 110.8(d)3:
Ducts. Insulation installed on an existing space-conditioning duct must comply with § 604.0 of the California Mechanical Code (CMC). If a
contractor installs the insulation, the contractor must certify to the customer, in writing, that the insulation meets this requirement.
§ 150.0(m)1:
CMC Compliance. All air-distribution system ducts and plenums must meet the requirements of the CMC §§ 601.0, 602.0, 603.0, 604.0, 605.0
and ANSI/SMACNA-006-2006 HVAC Duct Construction Standards Metal and Flexible 3rd Edition. Portions of supply-air and return-air ducts and
plenums must be insulated to a minimum installed level of R-6.0 or a minimum installed level of R-4.2 when ducts are entirely in conditioned
space as confirmed through field verification and diagnostic testing (RA3.1.4.3.8). Portions of the duct system completely exposed and
surrounded by directly conditioned space are not required to be insulated. Connections of metal ducts and inner core of flexible ducts must be
mechanically fastened. Openings must be sealed with mastic, tape, or other duct-closure system that meets the applicable requirements of UL
181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than ¼
inch, the combination of mastic and either mesh or tape must be used. Building cavities, support platforms for air handlers, and plenums
designed or constructed with materials other than sealed sheet metal, duct board or flexible duct must not be used to convey conditioned air.
Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms must not be compressed to cause
reductions in the cross-sectional area.*
§ 150.0(m)2:
Factory-Fabricated Duct Systems. Factory-fabricated duct systems must comply with applicable requirements for duct construction,
connections, and closures; joints and seams of duct systems and their components must not be sealed with cloth back rubber adhesive duct
tapes unless such tape is used in combination with mastic and draw bands.
§ 150.0(m)3:
Field-Fabricated Duct Systems. Field-fabricated duct systems must comply with applicable requirements for: pressure -sensitive tapes,
mastics, sealants, and other requirements specified for duct construction.
§ 150.0(m)7: Backdraft Damper. Fan systems that exchange air between the conditioned space and outdoors must have backdraft or automatic dampers.
§ 150.0(m)8:
Gravity Ventilation Dampers. Gravity ventilating systems serving conditioned space must have either automatic or readily accessible,
manually operated dampers in all openings to the outside, except combustion inlet and outlet air openings and elevator shaft vents.
§ 150.0(m)9:
Protection of Insulation. Insulation must be protected from damage, sunlight, moisture, equipment maintenance, and wind. Insulation exposed
to weather must be suitable for outdoor service. For example, protected by aluminum, sheet metal, painted canvas, or plastic cover. Cellular
foam insulation must be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation.
§ 150.0(m)10: Porous Inner Core Flex Duct. Porous inner core flex ducts must have a non-porous layer between the inner core and outer vapor barrier.
§ 150.0(m)11:
Duct System Sealing and Leakage Test. When space conditioning systems use forced air duct systems to supply conditioned air to an
occupiable space, the ducts must be sealed and duct leakage tested, as confirmed through field verification and diagnostic testing, in
accordance with § 150.0(m)11 and Reference Residential Appendix RA3.
§ 150.0(m)12:
Air Filtration. Space conditioning systems with ducts exceeding 10 feet and the supply side of ventilation systems must have MERV 13 or
equivalent filters. Filters for space conditioning systems must have a two inch depth or can be one inch if sized per Equation 150.0-A. Pressure
drops and labeling must meet the requirements in §150.0(m)12. Filters must be accessible for regular service.*
§ 150.0(m)13:
Space Conditioning System Airflow Rate and Fan Efficacy. Space conditioning systems that use ducts to supply cooling must have a hole
for the placement of a static pressure probe, or a permanently installed static pressure probe in the supply plenum. Airflow must be ≥ 350 CFM
per ton of nominal cooling capacity, and an air-handling unit fan efficacy ≤ 0.45 watts per CFM for gas furnace air handlers and ≤ 0.58 watts per
CFM for all others. Small duct high velocity systems must provide an airflow ≥ 250 CFM per ton of nominal cooling capacity, and an air-handling
unit fan efficacy ≤ 0.62 watts per CFM. Field verification testing is required in accordance with Reference Residential Appendix RA3.3.*
2019 Low-Rise Residential Mandatory Measures Summary
Requirements for Ventilation and Indoor Air Quality:
§ 150.0(o)1:
Requirements for Ventilation and Indoor Air Quality. All dwelling units must meet the requirements of ASHRAE Standard 62.2, Ventilation
and Acceptable Indoor Air Quality in Residential Buildings subject to the amendments specified in § 150.0(o)1.
§ 150.0(o)1C:
Single Family Detached Dwelling Units. Single family detached dwelling units, and attached dwelling units not sharing ceilings or floors with
other dwelling units, occupiable spaces, public garages, or commercial spaces must have mechanical ventilation airflow provided at rates
determined by ASHRAE 62.2 Sections 4.1.1 and 4.1.2 and as specified in § 150.0(o)1C.
§ 150.0(o)1E:
Multifamily Attached Dwelling Units. Multifamily attached dwelling units must have mechanical ventilation airflow provided at rates in
accordance with Equation 150.0-B and must be either a balanced system or continuous supply or continuous exhaust system. If a balanced
system is not used, all units in the building must use the same system type and the dwelling-unit envelope leakage must be ≤ 0.3 CFM at 50 Pa
(0.2 inch water) per square foot of dwelling unit envelope surface area and verified in accordance with Reference Residential Appendix RA3.8.
§ 150.0(o)1F:
Multifamily Building Central Ventilation Systems. Central ventilation systems that serve multiple dwelling units must be balanced to provide
ventilation airflow for each dwelling unit served at a rate equal to or greater than the rate specified by Equation 150.0-B. All unit airflows must be
within 20 percent of the unit with the lowest airflow rate as it relates to the individual unit’s minimum required airflow rate needed for compliance.
§ 150.0(o)1G:Kitchen Range Hoods. Kitchen range hoods must be rated for sound in accordance with Section 7.2 of ASHRAE 62.2.
§ 150.0(o)2:
Field Verification and Diagnostic Testing. Dwelling unit ventilation airflow must be verified in accordance with Reference Residential
Appendix RA3.7. A kitchen range hood must be verified in accordance with Reference Residential Appendix RA3.7.4.3 to confirm it is
rated by HVI to comply with the airflow rates and sound requirements as specified in Section 5 and 7.2 of ASHRAE 62.2.
Pool and Spa Systems and Equipment Measures:
§ 110.4(a):
Certification by Manufacturers. Any pool or spa heating system or equipment must be certified to have all of the following: a thermal efficiency
that complies with the Appliance Efficiency Regulations; an on-off switch mounted outside of the heater that allows shutting off the heater
without adjusting the thermostat setting; a permanent weatherproof plate or card with operating instructions; and must not use electric
resistance heating.*
§ 110.4(b)1:
Piping. Any pool or spa heating system or equipment must be installed with at least 36 inches of pipe between the filter and the heater, or
dedicated suction and return lines, or built-in or built-up connections to allow for future solar heating.
§ 110.4(b)2: Covers. Outdoor pools or spas that have a heat pump or gas heater must have a cover.
§ 110.4(b)3:
Directional Inlets and Time Switches for Pools. Pools must have directional inlets that adequately mix the pool water, and a time switch that
will allow all pumps to be set or programmed to run only during off-peak electric demand periods.
§ 110.5:Pilot Light. Natural gas pool and spa heaters must not have a continuously burning pilot light.
§ 150.0(p):
Pool Systems and Equipment Installation. Residential pool systems or equipment must meet the specified requirements for pump sizing, flow
rate, piping, filters, and valves.*
Lighting Measures:
§ 110.9:
Lighting Controls and Components. All lighting control devices and systems, ballasts, and luminaires must meet the applicable requirements
of § 110.9.*
§ 150.0(k)1A: Luminaire Efficacy. All installed luminaires must meet the requirements in Table 150.0-A.
§ 150.0(k)1B:
Blank Electrical Boxes. The number of electrical boxes that are more than five feet above the finished floor and do not contain a luminaire or
other device must be no greater than the number of bedrooms. These electrical boxes must be served by a dimmer, vacancy sensor control, or
fan speed control.
§ 150.0(k)1C:Recessed Downlight Luminaires in Ceilings. Luminaires recessed into ceilings must meet all of the requirements for: insulation contact (IC)
labeling; air leakage; sealing; maintenance; and socket and light source as described in § 150.0(k)1C.
§ 150.0(k)1D:
Electronic Ballasts for Fluorescent Lamps. Ballasts for fluorescent lamps rated 13 watts or greater must be electronic and must have an
output frequency no less than 20 kHz.
§ 150.0(k)1E:Night Lights, Step Lights, and Path Lights. Night lights, step lights and path lights are not required to comply with Table 150.0-A or be
controlled by vacancy sensors provided they are rated to consume no more than 5 watts of power and emit no more than 150 lumens.
§ 150.0(k)1F:
Lighting Integral to Exhaust Fans. Lighting integral to exhaust fans (except when installed by the manufacturer in kitchen exhaust hoods)
must meet the applicable requirements of § 150.0(k).*
§ 150.0(k)1G: Screw based luminaires. Screw based luminaires must contain lamps that comply with Reference Joint Appendix JA8.*
§ 150.0(k)1H:Light Sources in Enclosed or Recessed Luminaires. Lamps and other separable light sources that are not compliant with the JA8 elevated
temperature requirements, including marking requirements, must not be installed in enclosed or recessed luminaires.
§ 150.0(k)1I:
Light Sources in Drawers, Cabinets, and Linen Closets. Light sources internal to drawers, cabinetry or linen closets are not required to
comply with Table 150.0-A or be controlled by vacancy sensors provided that they are rated to consume no more than 5 watts of power, emit no
more than 150 lumens, and are equipped with controls that automatically turn the lighting off when the drawer, cabinet or linen closet is closed.
§ 150.0(k)2A: Interior Switches and Controls. All forward phase cut dimmers used with LED light sources must comply with NEMA SSL 7A.
§ 150.0(k)2B: Interior Switches and Controls. Exhaust fans must be controlled separately from lighting systems.*
§ 150.0(k)2C:
Interior Switches and Controls. Lighting must have readily accessible wall-mounted controls that allow the lighting to be manually
turned ON and OFF.*
§ 150.0(k)2D: Interior Switches and Controls. Controls and equipment must be installed in accordance with manufacturer’s instructions.
§ 150.0(k)2E:
Interior Switches and Controls. Controls must not bypass a dimmer, occupant sensor, or vacancy sensor function if the control is installed to
comply with § 150.0(k).
§ 150.0(k)2F: Interior Switches and Controls. Lighting controls must comply with the applicable requirements of § 110.9.
2019 Low-Rise Residential Mandatory Measures Summary
§ 150.0(k)2G:
Interior Switches and Controls. An energy management control system (EMCS) may be used to comply with control requirements if it:
provides functionality of the specified control according to § 110.9; meets the Installation Certificate requirements of § 130.4; meets the
EMCS requirements of § 130.0(e); and meets all other requirements in § 150.0(k)2.
§ 150.0(k)2H:
Interior Switches and Controls. A multiscene programmable controller may be used to comply with dimmer requirements in § 150.0(k) if it
provides the functionality of a dimmer according to § 110.9, and complies with all other applicable requirements in § 150.0(k)2.
§ 150.0(k)2I:
Interior Switches and Controls. In bathrooms, garages, laundry rooms, and utility rooms, at least one luminaire in each of these spaces must
be controlled by an occupant sensor or a vacancy sensor providing automatic-off functionality. If an occupant sensor is installed, it must be
initially configured to manual-on operation using the manual control required under Section 150.0(k)2C.
§ 150.0(k)2J:
Interior Switches and Controls. Luminaires that are or contain light sources that meet Reference Joint Appendix JA8 requirements for
dimming, and that are not controlled by occupancy or vacancy sensors, must have dimming controls.*
§ 150.0(k)2K: Interior Switches and Controls. Under cabinet lighting must be controlled separately from ceiling-installed lighting systems.
§ 150.0(k)3A:
Residential Outdoor Lighting. For single-family residential buildings, outdoor lighting permanently mounted to a residential building, or to other
buildings on the same lot, must meet the requirement in item § 150.0(k)3Ai (ON and OFF switch) and the requirements in either
§ 150.0(k)3Aii (photocell and either a motion sensor or automatic time switch control) or § 150.0(k)3Aiii (astronomical time clock), or an EMCS.
§ 150.0(k)3B:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, outdoor lighting for private patios, entrances,
balconies, and porches; and residential parking lots and carports with less than eight vehicles per site must comply with either § 150.0(k)3A or
with the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)3C:
Residential Outdoor Lighting. For low-rise residential buildings with four or more dwelling units, any outdoor lighting for residential parking lots
or carports with a total of eight or more vehicles per site and any outdoor lighting not regulated by § 150.0(k)3B or § 150.0(k)3D must comply with
the applicable requirements in Sections 110.9, 130.0, 130.2, 130.4, 140.7 and 141.0.
§ 150.0(k)4:
Internally illuminated address signs. Internally illuminated address signs must comply with § 140.8; or must consume no more than 5 watts of
power as determined according to § 130.0(c).
§ 150.0(k)5:
Residential Garages for Eight or More Vehicles. Lighting for residential parking garages for eight or more vehicles must comply with the
applicable requirements for nonresidential garages in Sections 110.9, 130.0, 130.1, 130.4, 140.6, and 141.0.
§ 150.0(k)6A:
Interior Common Areas of Low-rise Multifamily Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals 20 percent or less of the floor area, permanently installed lighting for the interior common areas in that
building must be comply with Table 150.0-A and be controlled by an occupant sensor.
§ 150.0(k)6B:
Interior Common Areas of Low-rise Multifamily Residential Buildings. In a low-rise multifamily residential building where the total interior
common area in a single building equals more than 20 percent of the floor area, permanently installed lighting for the interior common areas in
that building must:
i. Comply with the applicable requirements in Sections 110.9, 130.0, 130.1, 140.6 and 141.0; and
ii. Lighting installed in corridors and stairwells must be controlled by occupant sensors that reduce the lighting power in each space by at least
50 percent. The occupant sensors must be capable of turning the light fully on and off from all designed paths of ingress and egress.
Solar Ready Buildings:
§ 110.10(a)1:
Single Family Residences. Single family residences located in subdivisions with 10 or more single family residences and where the
application for a tentative subdivision map for the residences has been deemed complete and approved by the enforcement agency, which
do not have a photovoltaic system installed, must comply with the requirements of § 110.10(b) through § 110.10(e).
§ 110.10(a)2: Low-rise Multifamily Buildings. Low-rise multi-family buildings that do not have a photovoltaic system installed must comply with the
requirements of § 110.10(b) through § 110.10(d).
§ 110.10(b)1:
Minimum Solar Zone Area. The solar zone must have a minimum total area as described below. The solar zone must comply with access,
pathway, smoke ventilation, and spacing requirements as specified in Title 24, Part 9 or other parts of Title 24 or in any requirements adopted by
a local jurisdiction. The solar zone total area must be comprised of areas that have no dimension less than 5 feet and are no less than 80
square feet each for buildings with roof areas less than or equal to 10,000 square feet or no less than 160 square feet each for buildings with
roof areas greater than 10,000 square feet. For single family residences, the solar zone must be located on the roof or overhang of the building
and have a total area no less than 250 square feet. For low-rise multi-family buildings the solar zone must be located on the roof or overhang of
the building, or on the roof or overhang of another structure located within 250 feet of the building, or on covered parking installed with the
building project, and have a total area no less than 15 percent of the total roof area of the building excluding any skylight area. The solar zone
requirement is applicable to the entire building, including mixed occupancy.*
§ 110.10(b)2: Azimuth. All sections of the solar zone located on steep-sloped roofs must be oriented between 90 degrees and 300 degrees of true north.
§ 110.10(b)3A:
Shading. The solar zone must not contain any obstructions, including but not limited to: vents, chimneys, architectural features, and roof
mounted equipment.*
§ 110.10(b)3B:
Shading. Any obstruction located on the roof or any other part of the building that projects above a solar zone must be located at lea st twice the
distance, measured in the horizontal plane, of the height difference between the highest point of the obstruction and the horizontal projection of
the nearest point of the solar zone, measured in the vertical plane.*
§ 110.10(b)4:
Structural Design Loads on Construction Documents. For areas of the roof designated as a solar zone, the structural design loads for roof
dead load and roof live load must be clearly indicated on the construction documents.
§ 110.10(c):
Interconnection Pathways. The construction documents must indicate: a location reserved for inverters and metering equipment and a
pathway reserved for routing of conduit from the solar zone to the point of interconnection with the electrical service; and for single family
residences and central water-heating systems, a pathway reserved for routing plumbing from the solar zone to the water-heating system.
§ 110.10(d):
Documentation. A copy of the construction documents or a comparable document indicating the information from § 110.10(b) through
§ 110.10(c) must be provided to the occupant.
§ 110.10(e)1: Main Electrical Service Panel. The main electrical service panel must have a minimum busbar rating of 200 amps.
§ 110.10(e)2:
Main Electrical Service Panel. The main electrical service panel must have a reserved space to allow for the installation of a double pole circuit
breaker for a future solar electric installation. The reserved space must be permanently marked as “For Future Solar Electric”.