Loading...
BLD-2019-1198_AMMR FormALTERNATE MATERIALS AND METHODS / MODIFICATION FORM COMMUNI I DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO. CA 95014-3255 (408) 777-3228 • FAX (403) 777-3333 • buildinaLcurllno_org CUPERTINO ❑ REQUEST FOR MODIFICATION OF CODE (CBC 104.10, CFC 104.8) 0 REQUEST FOR ALTERNATE MATERIAL, DESIGN OR METHOD OF CONSTRUCTION (CBC 104.11, CFC 104.9) ❑ REQUEST FOR HARDSHIP EXEMPTION OR EQUIVALENT FACILITATION (HEALTH AND SAFETY CODE 19957) Tn nnniv fnr this rnnf oral CnrllnlnlP secfinns 1 2 & 3 tlflk or IVrle1 SITE 10235 S. DE ANZA BLVD, CUPERTINO, CA 95014 APN 359 10 060 ADDRESS DATE 05109/2021 weer Vardy PC #. .. .................. i'ype..��-A... -... - .. Address 1 D235 S. DE ANZA BLVD, CUPERTINO. CA 95014 aLD-2019-1196 1 ...... .. ...... ... ... Pe. nnil # ... ....... ... . ...... Stories En1ad.lm............. Phone..408...6.9.1..3.527..,... Dept./Div ..... ........ .. .... S 1PLN Occupancy. Floor Area.,,28D sgfl W.H. Yang SL rifle .. Applicant ...... ..... ...................... Address 1164 Susan Way, Sunnyvale, CA Job SIalLIS, .. .. Occ Load' ... .. ........ . w !1, an a hplmall ...... 4D8-329-8787 Email... ..}�..... ..........:...... ....... ........ .... Phone.........._....................... Use of Bldg: Trash enclosure �2 REQUEST: For coda modifications, please state the applicable code requirement and the extent of relief desired For alternate requests, state the type of system - OLtC7t3LKI and dc5J n melllods Submit 'Ins if I1RCC5'aaryr to ilitrstrate regueW Addihwlpt :J*CN of tlat7 Maly be attached 2. Not use fire sprinkler per fire code section rated fire wall, and the trash enclosure sari 3 I JUSTiFICATtONIFINDINGS OF EQUIVALENCY: FO auan4. applicant :lr( JII snerrit. urdwiAu:0 n ti,ons cx,,l that nk;4": enlrll f mu with if 1 clh:l of the wdavit�jt:�++'-- Intpt: ertuw;rlrney is llrpVrdI d- For ;rlterrltl le re.^rlt+arts. upplicant :I I nslralo s i Ii��e�rlglh. resrSlancr7. dtlfoLdl . safely arH1 MANIDIOrl that is el utwaleal do fora . 1 j tcTT Altach additional shaets if necessary EXP a� $D See -attached pages for -explanations. _ - &P. �. 'eliltvndr'�. ilnnautrc:.,.. - �............ Slnlsiunl Enpinrt:r Dale: U F'nsllttul ........ d 304.3.4 tam surrc aption 2, by using_? hour ng buildings. p<, to that Cade Seelion(s): �M ., lire CBC TBL 601. Section 706, CFC 304 :................ ..__., ............. Date. me Rrv.Itlrsi is Im GRAN ED ❑ OFNIED i7r pl Cnnmlents CONDITIONS OF APPROVAL. _ EN-TIRE--ROOE-STRUCTURE_SHALL_BE-COVERED-BY-__ -- -_.—•__._T _-- 1-HOUR FIREBATED. SHAFT .LIN.ER..EROIATHE -. _ No of Items UNDERSIDE. ALL 3 WALLS AT THE EAST. SOUTH FpcDLle S .-- AND WEST ELEVATIONS_ SHALL BE ENCAPSULATED Dale Paid BY 2-HOUR FIRE RATED EXTERIOR WALL.^ ---- - - - — — - — _ Rec:eipl140 Processed by �i a1�.t?Z-i w ! Htutdinl Cttlict 1 �� `� �Z a ,t lLO-w-rL, 1wi, Fire Marslr Plinl: - -.rnt 12..L ry-aJ w _ _ UCt'AK IIPIMN L,NI. IIVIV: Alter oelerl Illn�lllon, GOtne11 la if r p1mcanl, L) pernln mo I/ownr .'l/l?,lir rrl'nr,/0-0/ Ii Exalanations: According to the 2016 California Fire Code Section 304, 304.3.3 and 304.3.4, Exceptions 2:" Storage in a structure shall not be prohibited where the structure is of Type I or IIA construction, located not less than 10 feet from other buildings and used exclusively for dumpster or container storage." The Alternate Materials and Methods Justifications for the close proximity of the buildings is that the Exterior Wall of the Trash Enclosures will be fully enclosed with no openings per Table 705.8, and no parapet is constructed so the first 10-feet of the roof will be 1-hour fire rated per section 706.1.1, and the entire roof doesn't have to be fire rated. The attached sheets A-2 and S-2 shows that firewalls will be provided within 10 feet distance from the neighboring buildings according to 2016 CBC Section 706 and 706.1. The trash enclosure is a structure detached from the main building allowing collapse from either side, and it is consistent to the CBC 706.2. According to the 2016 California Building Code, Table 601, for the roof construction of TYPE II A construction, there is a note c says that: "In all occupancies, heavy timber shall be allowed where a 1-hour or less fire -resistance rating is required." For the proposed roof construction, the fire protection of the 1st 10-feet of ceiling is designed according to AER-09038/ UL Design K504 (see detail 1/S3), which is a listed and approved assembly. The system has no void and/or gaps, and, therefore, is equivalent to the intent of "heavy timber" in the aspect of fire rating. We have also attached the relevant code pages for the convenience of reviewing