Loading...
CC 12-05-2023 Item No. 8. Attachment F - Solar Array Seismic Design LetterDodd Mossa & Associates, LLC Consulting Engineers 7490 Opportunity Rd. Suite 3500 San Diego, CA 92111 (619)260-0057 June 09, 2023 Desmond Wheatley CEO Beam Global 5660 Eastgate Dr. San Diego, CA 92121 (858) 799-4583 desmond.wheatley(a beamforall.com Re: Beam Global - Solar Array Seismic Design (EV-ARC 2020) Dear Desmond, Based on our structural calculations preformed for the EV-ARC 2020 solar array, the system appears to not be overstressed under the design of 160mph under the ASCE 7- 16. This wind speed is based on a nominal design speed for a 3 second gust as prescribed in the American Society of Civil Engineers (ASCE). Calculations were been based on an assumption of a maximum Exposure category of C, the installation location not being atop an escarpment, or any type of hill, and with a maximum ground snow load of Opsf based on Sunnyvale, California installation location, as a high seismic risk region. Seismic load has been considered with a site specific Sds value of 1.2 for the proposed installation. It should be noted that no sliding occurs against a concrete surface, where the coefficient of friction was assumed as 0.55. Also, it should be noted that the structure is not embedded into soil and full seismic ground motions will not translate to the structure because of its construction type. Please contact our office if you have any questions or concerns. Sincerely, ES L. oo Fti 822 Exp. Sf9 CIVIL OF Cp iO Jerry Dodd, P.E.