BLD-2023-0828_JobCard (2).pdfINDEX ABBREVIATIONS ELECTRICAL NOTES VICINITY MAP JURISDICTION NOTES REV BY DATE COMMENTS REV A ES 5/19/2023 MOVED BLC CLOSER TO THE GATEWAY REV B ES 6/8/2023 LAYOUT CHANGE * * ** * * ** * * ** LICENSE GENERAL NOTES Arnold Hom 07/25/23 07/26/23 BLD-2023-0828 Kim Dunbar Front Of House (E) DRIVEWAY A B 18" FSB 18" FS B 18" FSB 18 " F S B 1 8 " F S B 12 " F S B 18" FSB 18 " F S B 18" FSB 1 8 " F S B 18 " FS B 1 8 " F S B 12 " F S B 18" F SB 18 " FS B 18" FSB 18" FSB 18" FS B 18" FSB 1 8 " F S B 18" FS B18" FSB Pitch 4/12 MP 1 Pitch 4/12 MP 2 Scale: 3/32" = 1' SITE PLAN 0 1'10' 21' LEGEND MP2 18° (4:12) 97 18° (4:12) 97 S-Tile (Cement)2 Stories MP1 18° (4:12) 277 18° (4:12) 277 S-Tile (Cement)2 Stories #SSTAMPCA #ESTAMPCA B Ryan Atwell Digitally signed by Ryan Atwell Date: 2023.06.14 16:23:28 -05'00' Arnold Hom 07/25/23 S1 SIDE VIEW OF MP2 NTS STORIES: ROOF AZI PITCH ARRAY AZI PITCH MP2 97 18 97 18 S-Tile (Cement) 22x8 @ 24" OC 2x10 @24" OC RAFTER C.J. B S1 SIDE VIEW OF MP1 NTS STORIES: ROOF AZI PITCH ARRAY AZI PITCH MP1 277 18 277 18 S-Tile (Cement) 22x8 @ 24" OC 2x10 @24" OC RAFTER C.J. A Scale: 1 1/2" = 1' STANDOFFS1 #SSTAMPCA ” Arnold Hom 07/25/23 ¨ þ ¨ þ þ ATTACHMENT: FRONT VIEW POWERWALL+ NTS SIDE VIEW ONE POWERWALL+ WALL ATTACHMENT: WALL MOUNT NTS #SSTAMPCA Arnold Hom 07/25/23 #SSTAMPCA Arnold Hom 07/25/23 A B C 3 D 3 E 2 1 S1A S1B 1 F #ESTAMPCA B B Arnold Hom 07/25/23 SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN CAUTION: MULTIPLE SOURCES OF POWER - Address: 18780 Hanna Dr OPERATING VOLTAGE = 240V JB-95019379-00 B Arnold Hom 07/25/23 NEC_2020-690_31_D_2 Per Code: 690.31.D.2 Label Location: (C)(IC)(CB) NEC_2020-690_53 Per Code: 690.53 Label Location: (DC) (INV) NEC_2020-690_13_B Per Code: 690.13.B Label Location: (AC) (POI)(DC) (INV) NEC_2020-690_54 Per Code: 690.54 Label Location: (AC) (POI) NEC_2020-690_13_B-3 Per Code: 690.13.B Label Location: (DC)(CB) NEC_2020-705_12_B_3_2 Per Code: 705.12.B.3.2 Label Location: (POI) NEC_2020-705_12_B_3_3 Per Code: 705.12.B.3.3 NEC_2020-705_12_C Per Code: 705.12.C Label Location: (POI) NEC_2020-690_54-690_13_B Per Code: 690.54; 690.13.B Label Location: (POI) UL_1741_Power_Control_System Per Code: UL 1741 Power Control System Label Location: (INV)(LC) NEC_2020-690_56_C_2 Per Code: 690.56.C.2 Label Location: RSD Switch NEC_2020-690_56_C Per Code: 690.56.C Label Location: (INV) (POI): Point of Interconnection (M): Utility Meter (LC): Load Center (INV): Inverter With Integrated DC Disconnect (IC): Interior Run Conduit (DC): DC Disconnect (D): Distribution Panel (CB): Combiner Box (C): Conduit (AC): AC Disconnect Label Set Arnold Hom 07/25/23 NEC_2020-408_4 Per Code: 408.4 Label Location: (BLC) NEC_2020-220 Per Code: 220 Label Location: (BLC) NEC_2020-312_8_A_3 Per Code: 312.8.A.3 Label Location: (MSP) NEC_2020-705_12_C-1 Per Code: 705.12.C Label Location: (MSP) NEC_2020-706_15_C-2 Per Code: 706.15.c Label Location: (AC) NEC_2020-705_12_B_3_2 Per Code: 705.12.B.3.2 Label Location: (POI) NEC_2020-705_12_B_3_3 Per Code: 705.12.B.3.3 NEC_2020-705_12_C-2 Per Code: 705.12.C Label Location: (MSP) UL_1741_Power_Control_System Per Code: UL 1741 Power Control System Label Location: (INV)(LC) IRC_2021-R_328_11 Per Code: R328.11 Label Location: (MSP) NEC_2020-706_15_C Per Code: 706.15.C Label Location: (MSP) (MSP): Main Service Panel (BLC): Backup Load Center (AC): AC Disconnect Label Set Arnold Hom 07/25/23 ZS SPAN DATASHEET 2 SPECIFICATIONS Designed for pitched roofs. Installs in portrait and landscape orientations. Engineered for spans up to 72” and cantilevers up to 24”. ZS Span has a UL 1703 Class “A” Fire Rating when installed using modules from any PDQXIDFWXUHUFHUWL¿HGDV³7\SH´RU³7\SH´ Attachment method UL listed to UL 2582 for Wind Driven Rain. 50 psf (2400 Pa) front side and 85 psf (4070 Pa) rear side design load rating. Engineered for compliance with ASCE 7-05, 7-10, and 7-16 wind load requirements. Zep wire management products listed to UL 1565 for wire positioning devices. ZS Span grounding products are listed to UL 2703 and UL 467. ZS Span bonding products are listed to UL 2703. Listed to UL 2703 Part #850-1625 DESCRIPTION PV mounting solution for concrete tile roofs. Works with all Zep Compatible Modules. Auto bonding UL-listed hardware creates structural and electrical bond. Listed to UL 2703 & UL 2582 for Wind Driven Rain Part #850-1461 Listed to UL 2703 Part #850-1627 Listed to UL 2703 Part #850-1554 ROOFING SYSTEM SPECIFICATIONS DOC-0065160 SPLICE ASSEMBLY KIT, SPANSPANNER BAR (VARYING LENGTHS) SPANNER CLAMP V2 MIGHTY HOOK V2 ZS SPAN DATASHEET 3 INTERLOCK GROUND ZEP CAM FOOT V2 DC WIRE CLIP HOME RUN CLIP Listed to UL 1565 Part #850-1510 ARRAY SKIRT END CAP Listed to UL 2703 Part #850-1511 Listed to UL 2703 Part #850-1613 Listed to UL 2703 Part #850-1608 Listed to UL 2703 Part #850-1606 Listed to UL 2703 Part #850-1586 (Left) Part #850-1588 (Right) SKIRT GRIP Listed to UL 2703 Part #850-1564 Listed to UL 1565 Part #850-1509 DOC-0065160 Listed to UL 2703 Part #850-1281 HYBRID INTERLOCK Arnold Hom 07/25/23 DC- DC+ 1 GD x x x x x DC1 Arnold Hom 07/25/23 TESLA.COM/ENERGY BACKUP SWITCH ENVIRONMENTAL SPECIFICATIONS Operating Temperature –40°C to 50°C (–40°F to 122°F) Storage Temperature –40°C to 85°C (–40°F to 185°F) Enclosure Rating NEMA 3R Pollution Rating PD3 PERFORMANCE SPECIFICATIONS Model Number 1624171-xx-y Continuous Load Rating 200A, 120/240V Split phase Short Circuit Current Rating 22 kA with breaker1 Communication CAN Product Compatibility Powerwall 2 with Backup Gateway 2, Powerwall+ Expected Service Life 21 years Warranty 10 years COMPLIANCE INFORMATION Safety Standards USA: UL 414, UL 2735, UL 916 CA Prop 65 Emissions FCC, ICES 2022-03-02 2 Manually overrides the contactor position during a service event. MECHANICAL SPECIFICATIONS Dimensions 176 mm x 205 mm x 74 mm (6.9 in x 8.1 in x 2.9 in) Weight 2.8 lbs Meter and Socket Compatibility ANSI Type 2S, ringless or ring type External Service Interface Contactor manual override2 Reset button Conduit Compatibility 1/2-inch NPT 1 Breaker size must be equal to or greater than the available fault current. 1 75.8 204.86 74 The Tesla Backup Switch controls connection to the grid in a Powerwall system, and can be easily installed behind the utility meter or in a standalone meter panel downstream of the utility meter. The Backup Switch automatically detects grid outages, providing a seamless transition to backup power. It communicates directly with Powerwall, allowing home energy usage monitoring from any mobile device with the Tesla app. 176 mm 205 mm 74 mm Arnold Hom 07/25/23 TESLA.COM/ENERGY POWERWALL+ Powerwall+ is an integrated solar battery system that stores energy from solar production. Powerwall+ has two separate inverters, one for battery and one for solar, that are optimized to work together. Its integrated design and streamlined installation allow for simple connection to any home, and improved surge power capability brings whole home backup in a smaller package. Smart system controls enable owners to customize system behavior to suit their renewable energy needs. KEY FEATURES • Integrated battery, inverter, and system controller for a more compact install • A suite of application modes, including self-powered, time-based control, and backup modes • Wi-Fi, Ethernet, and LTE connectivity with easy over-the-air updates NA 2023-01-09 TESLA.COM/ENERGY POWERWALL+ COMPLIANCE INFORMATION PV Certifications UL 1699B, UL 1741, UL 3741, UL 1741 SA, UL 1741 SB, UL 1998 (US), IEEE 1547, IEEE 1547.1 Battery Energy Storage System Certifications UL 1642, UL 1741, UL 1741 PCS, UL 1741 SA, UL 1741 SB, UL 1973, UL 9540, IEEE 1547, IEEE 1547.1, UN 38.3 Grid Connection United States Emissions FCC Part 15 Class B Environmental RoHS Directive 2011/65/EU Seismic AC156, IEEE 693-2005 (high) ENVIRONMENTAL SPECIFICATIONS Operating Temperature –20°C to 50°C (–4°F to 122°F)8 Recommended Temperature 0°C to 30°C (32°F to 86°F) Operating Humidity (RH)Up to 100%, condensing Storage Conditions –20°C to 30°C (–4°F to 86°F) Up to 95% RH, non-condensing State of Energy (SoE): 25% initial Maximum Elevation 3000 m (9843 ft) Environment Indoor and outdoor rated Enclosure Type Type 3R Solar Assembly Ingress Rating IP55 (Wiring Compartment) Battery Assembly Ingress Rating IP56 (Wiring Compartment) IP67 (Battery & Power Electronics) Noise Level @ 1 m < 40 db(A) optimal, < 50 db(A) maximum MECHANICAL SPECIFICATIONS Dimensions 1596 x 755 x 160 mm (62.8 x 29.7 x 6.3 in) Total Weight 140 kg (310 lb)7 Battery Assembly 118 kg (261 lb) Solar Assembly 22 kg (49 lb) Mounting options Floor or wall mount 1Values provided for 25°C (77°F), 3.3 kW charge/discharge power. 2Load start capability may vary. 3Where the DC input current exceeds an MPPT rating, jumpers can be used to allow a single MPPT to intake additional DC current up to 26 A Imp / 34 A Isc. 4Power factor rating at max real power. 5AC to battery to AC, at beginning of life. 6Cellular connectivity subject to network service coverage and signal strength. 7The total weight does not include the Powerwall+ bracket, which weighs an additional 9 kg (20 lb). 8Performance may be de-rated at operating temperatures below 10°C (50°F) or greater than 43°C (109°F). NA 2023-01-09 PHOTOVOLTAIC (PV) AND BATTERY ENERGY STORAGE SYSTEM (BESS) SPECIFICATIONS Powerwall+ Model Number 1850000-xx-y Solar Assembly Model Number 1538000-xx-y Nominal Battery Energy 13.5 kWh1 Nominal Grid Voltage (Input / Output) 120/240 VAC Grid Voltage Range 211.2 - 264 VAC Frequency 60 Hz Phase 240 VAC: 2W+N+GND Maximum Continuous Power On-Grid 7.6 kVA full sun / 5.8 kVA no sun1 Maximum Continuous Power Off-Grid 9.6 kW full sun / 7 kW no sun1 Peak Off-Grid Power (10 s) 22 kW full sun / 10 kW no sun1 Maximum Continuous Current On-Grid 32 A output Maximum Continuous Current Off-Grid 40 A output Load Start Capability 98 - 118 A LRA2 PV Maximum Input Voltage 600 VDC PV DC Input Voltage Range 60 - 550 VDC PV DC MPPT Voltage Range 60 - 480 VDC MPPTs 4 Input Connectors per MPPT 1-2-1-2 Maximum Current per MPPT (Imp) 13 A3 Maximum Short Circuit Current per MPPT (Isc) 17 A3 Allowable DC/AC Ratio 1.7 Overcurrent Protection Device 50 A breaker Maximum Supply Fault Current 10 kA Output Power Factor Rating +/– 0.9 to 14 Round Trip Efficiency 90%1,5 Solar Generation CEC Efficiency 97.5% at 208 V 98.0% at 240 V Customer Interface Tesla Mobile App Internet Connectivity Wi-Fi, Ethernet, Cellular LTE/4G)6 PV AC Metering Revenue grade (+/-0.5%) Protections Integrated arc fault circuit interrupter (AFCI), PV Rapid Shutdown Warranty 10 years 160 mm 1596 mm 755 mm Arnold Hom 07/25/23 TESLA.COM/ENERGY SYSTEM LAYOUTS Powerwall+ with Backup Switch Installed Behind Utility Meter Powerwall+ with Backup Switch Installed Downstream of Utility Meter NA 2023-01-09 TESLA.COM/ENERGY Powerwall+ with Backup Gateway 2 for Whole Home Backup Powerwall+ with Backup Gateway 2 for Partial Home Backup NA 2023-01-09 Arnold Hom 07/25/23 Tesla Module Datasheet (TEPV-DS-0011-21) Tesla Photovoltaic Module T395H, T400H, and T405H — The Tesla module is one of the most powerful residential photovoltaic modules available and exceeds industry engineering and quality standards. Featuring our proprietary Zep Groove design, the all-black module mounts close to your roof for a minimalist aesthetic. Modules are certified to IEC / UL 61730 - 1, IEC / UL 61730 - 2 and IEC 61215. Tesla Module Datasheet (TEPV-DS-0011-21) T400H T395H T405H STC NMOTSTCNMOT STC NMOT 400 300.1395296.3 405 303.8 45.30 42.7245.27 42.69 45.34 42.76 11.14 8.9711.10 8.95 11.17 9.00 37.13 35.2536.88 35.03 37.39 35.46 10.77 8.5110.71 8.46 10.83 8.57 t 20.4 t 20.1 t 20.6 1000 W/m2, 25°C, AM1.5 800 W/m2, 20°C, AM1.5, wind speed 1 m/s +0.04% / °C -0.34% / °C -0.27% / °C 4080 Pa | 85 lb/ft2 4080 Pa | 85 lb/ft2 35 mm at 27.2 m/s 6120 Pa | 128 lb/ ft2 6120 Pa | 128 lb/ ft2 132 (6 x 22) 4 mm2 | 12 AWG, 1325 mm | 47.2 in. Length IP68, 3 diodes Staubli MC4 0.13 in (3.2 mm) thermally pre-stressed glass 23.5 kg | 51.8 lb Black Anodized Aluminum Alloy 1890 mm x 1046 mm x 40 mm 74.4 in x 41.2 in x 1.57 in -40°C up to +85°C 20 A +/- 5% Class II -0 /+5W 45.7 +/- 3 °C DC 1000 V (IEC/UL) UL 61730 Type 2 25 years 25 years 0 12 Cell Temp = 25°C 8 4 10 6 2 0 5 0 40 30 20 10 Cu r r e n t ( A ) Voltage (V) 800 W/m2 400 W/m2 1000 W/m2 600 W/m2 200 W/m2 0 450 Cell Temp = 25°C 300 100 400 150 0 5 040 30 20 10 Po w e r ( W ) Voltage (V) 800 W/m2 400 W/m2 1000 W/m2 600 W/m2 200 W/m2 350 250 50 200 0 10 0 5 040 30 20 10 Cu r r e n t ( A ) Voltage (V) 12 8 2 6 4 11 5 0 m m | 4 5 . 3 i n 18 9 0 m m | 7 4 . 4 i n 40 +/- 0.5 mm 1.57 +/- 0.020 in 1046 mm | 41.2 in 13 2 5 m m | 4 7 . 2 i n 40 m m / 1 . 5 7 5 i n 35 mm / 1.378 in Wa r r a n t e d P m a x Year 98% 86% 80% 2520 0 1 10 5 15 85% 90% 95% Incident Irradiance = 1000 W/m2 Cell Temp=35ºC Cell Temp=25ºC Cell Temp=45ºC Cell Temp=55ºC Cell Temp=65ºC Cell Temp=75ºC Electrical Characteristics Front Side Design Load Mechanical Loading Rear Side Test Load Power Class Short Circuit Current, ISC (A) Max Power, PMAX (W) Max Power Current, IMP (A) Test Method Max Power Voltage, VMP (V) Open Circuit Voltage, VOC (V) Module Efficiency (%) STC NOCT Hail Test Rear Side Design Load Front Side Test Load Cell Orientation Front Cover Cable Weight Junction Box Frame Connector Dimension Mechanical Parameters Operational Temperature Max Series Fuse Rating VOC & ISC Tolerance Safety Class Power Output Tolerance NOCT Max System Voltage Fire Rating Operation Parameters At least 98% of nominal power during first year. Thereafter max. 0.5% degradation per year. At least 93.5% of nominal power up to 10 years. At least 86% of nominal power up to 25 years. Linear Power Warranty Materials and Processing Extra Linear Power Output Current vs. Voltage Power vs. Voltage Current vs. Voltage IV Curves Temperature Coefficient of Isc Temperature Coefficient of PMAX (W) Temperature Coefficient of VOC Temperature Rating (STC) Module Specifications Refer to module and system installation manuals for allowable design loads, foot spacings, and cantilever specifications. Arnold Hom 07/25/23 Tesla Solar Shutdown Device 1 Datasheet Electrical Specifications Nominal Input DC Current Rating (IMP)12 A Maximum Input Short Circuit Current (ISC)19 A Maximum System Voltage (PVHCS)600 V DC Solar Shutdown Device 1 Technical Specifications Environmental Specifications Ambient Temperature -40°C to 50°C (-40°F to 122°F) Storage Temperature –30°C to 70°C (–22°F to 158°F) Enclosure Rating NEMA 4X / IP65 Compliance Information Certifications UL 1741 PVRSE, UL 3741, PVRSA (Photovoltaic Rapid Shutdown Array) RSD Initiation Method PV System AC Breaker or Switch Compatible Equipment See Compatibility Table below Mechanical Specifications Model Number MCI-1 Electrical Connections MC4 Connector Housing Plastic Dimensions 125 mm x 150 mm x 22 mm (5 in x 6 in x 1 in) Weight 350 g (0.77 lb) Mounting Options ZEP Home Run Clip M4 Screw (#10) M8 Bolt (5/16") Nail / Wood screw RSD Module Performance Maximum Number of Devices per String 5 Control Power Line Excitation Passive State Normally Open Maximum Power Consumption 7 W Warranty 25 years — The Solar Shutdown Device is a Mid-Circuit Interrupter (MCI) and is part of the PV system rapid shutdown (RSD) function in accordance with Article 690 of the applicable NEC. When paired with Powerwall+ or Tesla Solar Inverter, solar array shutdown is initiated by any loss of AC power. 650 mm 150 mm 125 mm 250 mm M4 Screw M8 Bolt Nail / Wood Screw 22 mm UL 3741 PV Hazard Control (and PVRSA) Compatibility Tesla Solar Roof and Tesla/Zep ZS Arrays using the following modules are certified to UL 3741 and UL 1741 PVRSA when installed with Powerwall+ or Tesla Solar Inverter and Solar Shutdown Devices. See Powerwall+ / Tesla Solar Inverter Rapid Shutdown: Module Selection Based on PV Hazard Control System Listing for guidance on installing other modules. Brand Model Required Solar Shutdown Devices Tesla Solar Roof V3 1 Solar Shutdown Device per 10 modules Tesla Tesla TxxxS (where xxx = 405 to 450 W, increments of 5) Tesla TxxxH (where xxx = 395 to 415 W, increments of 5) 1 Solar Shutdown Device per 3 modules 1 Hanwha Q.PEAK DUO BLK-G5 or Q.PEAK DUO BLK-G6+ 1 Solar Shutdown Device per 3 modules 1 Exception: Tesla solar modules installed in locations where the max Voc for three modules at low design temperatures exceeds 165 V shall be limited to two modules between Solar Shutdown Devices. January 31, 2023 Arnold Hom 07/25/23