RM-2023-034 - 3 SITE PLAN REVISIONS
REV r DATE BY
DESIGNERS SICsN,ATURE
THE PLANS, IDEAS AND DESIGNS SHOWN
ON THESE DRAWINGS ARE THE PROPERT
OF THE DESIGNER. DEVISED SOLEY FOR
THIS PROJECT. PLANS SHALL NOT BE
USED,WHOLE OR IN PART,FOR ANY
OTHER PURPOSE WITHOUT THE WRITTEN
PERMISSION MICHELLE MINER DESIGN
CUPERTINO SANITARY DISTRICT
NEW UPPER FLOOR
RLID MARKED "SEWER" 6'EXISTING WOOD FENCE O CD 5' MAX -------- — ------ — — — — — — — — — ---�-------- — — O
GRADE x x x xLx -----x x x x x x x� x x x x x
I 1o"QIAGNOLIA xLo
NEW LOWER LIVING 0"MAGNO A I O O
IL Lr, P.
Q I
REMOVABLE THREADED
CAP PVC SDR26
I
NEW GARAGE EXISTING LANDSCAPING TO REMAIN d pq w� cz
I SET CHR I STY BOX ON I NO NEW LANDSCAPING '' F O W
TOP OF BRICKS LAID
p i
7RADIALLY OR 8"x8" OF I ECy\ s�
w VERT I CAL cz
3/4" CRUSHED ROCK I AREA ADDED 69 S.F. MA PDa. —
8 cu
w RISER NEW ENCLOSED PORCH
Paz I �1 •�
>as 1 ALL DOWNSPOUTS SHALL , (D
c0i m w 1/e BEND I I TERMINATE TO 24" r^
z o 45' WYE I SP ASHBLOCKS i t W
NEW ACCESSORY STRUCTURE
3/4" CRUSHED ANGULAR — — r ——————-- -- -- — — — — — — ELETRPC SERV CE ��
a F o PLAIN END ROCK.
ca co
wi m PVC SDR26 I I BATH V 0)
w I o (3) 0
Q
10'-OCOUP "
BAND LSEE no1 i ING 0 0)
CO
UPLING
NOTE 3 EE SETBACK I I W O M
NOTE 3 9 �' NOOK 1 y
p p G a� 6" TYP CID
EXISTING PVC OR VCP - - PROPERTY LINE 1 I •------ BEDROOM I <� co O
(UPPER LATERAL) 1 a 0
Ict
----------- --�--- I 1_4
TO MA//V SETBACK LINE I FAMILY ROOM a co
----------- __ CLOSET
_____ IIM-�-II
I
4" MIN SITE DRAINAGE PATTERN
4 I ✓O ��
x 6'EXISTING WOOD FENCE
!I I ���\\
p �l ` ' x
11 . ALL PIPING AND FITTINGS SHALL BE PVC SDR26. SITE PLAN NOTES I B T \\ w
2. CLEANOUT BOX SHALL BE OLDCASTLE PRECAST F08 WITH F08C FOR NON—TRAFFIC — a
AREA AND G05T WITH G05CT IN TRAFFIC AREA OR APPROVED EQUAL. SITE GRADING AND PAVING WILL MANAGE SURFACE WATER AWAY FROM0°
3. CONNECTION TO LOWER SANITARY SEWER LATERAL BUILDINGS 0 _ - z O
A. EXISTING LATERAL— MAKE CONNECTION TO EXISTING LATERAL IN GOOD CONDITION KITCHEN ® i BEDROOM#2 �
�� n EXISTING PUBLIC RIGHT OF WAY-ANY CONSTRUCTION WITHIN THE 1 \
AS DETERMINED BY THE ENGINEER WITH MISSION CLAY ARC SHIELDED , FERNCO �—�
"SHEAR RING COUPLING" OR APPROVED EQUAL. RIGHT-OF-WAY MUST HAVE AN APPROVED"PERMIT FOR CONSTRUCTION IN
THE PUBLIC STREET"PRIOR TO THE COMMENCEMENT OF THIS WORK.THE
B. NEW LATERAL— SEE DETAIL 6 FOR LOWER LATERAL. CONNECT LATERAL WYE PERFORMANCE OF THIS WORK IS NOT AUTHORIZED BY THE BUILDING I
DIRECTLY TO LOWER LATERAL PERMIT ISSUANCE BUT SHOWN ON THE BUILDING PERMIT FOR 0
4. CLEANOUT,ONCE INSTALLED AND APPROVED BY THE DISTRICT, BECOMES PRIVATELY INFORMATION ONLY.
OWNED AND MAINTAINED BY PROPERTY OWNER. WATER METER-CONTRACTOR TO COORDINATE(N)METER WITH LOCAL
WATER COMPANY.IF REQUIRED BY INCREASED FIXTURE LOAD. I
DINING IL r
ELECTRICAL METER LOCATION-CONTRACTOR TO COORDINATE WITH PG&E ^�^
FOR UPGRADE TO(E)ELECTRICAL SERVICE IF APPLICABLE. F•�•I LAUND BEDROOM#3
PROPERTY LINE CLEANOUT DETAIL 7 1 I j
UFER GROUND CONNECTION PER CEC 250-52 IF APPLICABLE. 14
DR. BY: DATE: CK. BY: DATE: I W
JB 05/04/2020 RTK 05/04/2020 APPROVED. BY: � DATE: 05/04/2020 (E)TREE(S)TO REMAIN-PROTECTED AS REQUIRED DURING CONSTRUCTION l
ENTRY
FOR EXTENDED
PERIODS ODO NOT LEAVE ME SEE AIRPORTS REPORTS TERIALS ORTI P ROV DAS EDIN ROOTE FOR ADDITIONAL GZ•I 1 I o
( ) ELEVATED TO 7'
INFORMATION. I 1 lJ • O
HARDSCAPE SLOPE AWAY FROM HOUSE AT 2%MIN. MMN
(N)36"MIN.DEEP LEVEL LANDING PER CRC 311.3 W STEPS(MAX'7.'75 RISER W / O
-PROVIDE EQUAL RISERS IF MORE THAN ONE STEP. I GARAGE
(N)A/C UNIT CONDENSER PAD(S)PROVIDE ELECTRICAL TO THIS LOCATION I
AS REQUIRED,VERIFY SIZE AND QUANTITY WITH HVAC CONTRACTOR.A/C CITY S AMP AREA
UNITS TO COMPLY WITH JURISDICTION'S NOISE ORDINANCE.IF APPLICABLE AREA ADDED 105 S.F.
LIVINGROOM O
CURB CUT PER LOCAL JURISDICTION STANDARDS DETAIL.IF APPLICABLE
Fa
IxI 11 T
— — — — — — — — - I -_ 1'.AVEB WITHIN 5 yF PROP TY
E V\J ARLA VINE TO BE FIRE RATED.SE 3
I [all new property line cleanou[[o Dis[ric[Os standards.See attached detail.Property line cleanou[must be within 6 fee ETA1L y ON DETAIL SHEE
e property line.Cl-...shall be the same diameter as the street portion of the serwce lateral.Gravity lateral is 40
(Dimkt
ameter.(O.C.4101)
Current PLCO hasoffset GAS METEupertino Sanitary District Initial(Visual)Inspection reqired.Contractor shall leave new pipe installation exposed.Donot
ckfil.Owner to contact District 48 hours pior to schedulinga Dis xt Inspector fora visual inspection.(O.C.Sao3) s r T - - n --- - r - 1 pertino Sanitary District Final(CCTV)Inspection and Approvalf thenew property line cleanout,pint of connection,and _lateral is re uv d r'r w clearance far Ci f Cu 1no Final Ins a don.Owner must aLLow Dimkt at least 8 _ _ _ _q e P,a ty Per[' P c 4 I T,— T.1- T. T. T.T . . T
urs0 notice to schedule a District Inspector fora id-inspecdon.Disttict to provide Building Department with written D o D o D o D o D D D o D o D D o D o D D o D.
a _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ I I
nodficadon upon completion of inspection.(O.C.yroa) ° ° ° ° a q a, ,a NO CHANGES TO VERALL GRADE
00 . oo . a .°oo a ./0 1. °(Q I?RIVEWA,Y�dn . as .°aoa ^1
Storm—,surface or roof drains and other al snrtare water runoff,shall not be disrhw a to the sanity D.'P D.'P D P D.'P .P D. D.P D. D.'P; D.'P D.' � VERIFY OR PROVIDE 5%SLOPE AWAY y� �
genet ge ry sewer. ° °/ ° d °/°
° a ° a ° a°P, a ° ° ° a ° a P p a a ° p°
a d a h
Tne cn emno rani Distort rerommenas mstalun me re cored im rovements near[he be in of the r�eot in case FROM THE BUILDING F RAT LEAST 1 'p tary g 9 P g mng P o� 1 ° ° a l ° / ° t° .a B �6r9n'�� Da �aa .7 O O POE ,� �1■
any unfor een issues arise with[he installations. 6•a �•a �•a •_I• �•a �'•a/• �•a •\ •4�a�'f• o�• a� �a •�•_°•a
Tne p P°a a'°o a'ao cQ�.D a'ao ,I,°•P, a'°s° 'aa° a's,I, p, 'a°p /a p 'S
AWAY FROM BUILDING AND SLOPE AWAY F OM
na naly rere an wea trcdtrum NEIGHBORS PROP RTY.ALL RUNOFF SHALL pipo beusatsaoy. 4a4a1a4a .4a x I
BE MAINTAINED C N SITE AND
> I I
DRAING TO EXIST NG LANDSCAPING
I•o °Uo .°Uo -r� rE^'"1tI °�o ,/�•o Uo-ram �a Ual °aa U.a / p.a u;, ip.a •°pl.a a
:I --ire - -- --6--- --- -----------------------------0- --------------- ----------- -
I E+°
40a
O
FRONT YARD= 1200 S.F. 4 ° EXISTNG LAWN TC REM N i �—
D
FRONT YARD IMPERVIOUS PAVING=EXISTING DRIVEWAY 600 S.F.(50%) ° ° "4 °°°4 °°r °/" 'I° ° ° 1 °°r p,°4/° IS°} 2&;e a °;. p, NO NEW LANDSCA IN
PP i D D P I o.Xa Q° a .tad LD aoa .� pIQA°It�{ 3GD
° P.. 4 1FAR SIN aS,llk� p,°/4 d° °° 4 °a°a °°°)a p, I E3
aa� �. oa . as .iaa I
Di o D .A I D.'P /D.'o D.'o D T '
Ia°.� .aka ali pm aim �0•dl 4��'d .aka°.4Ua°. /JI�`�'-����I'�'Da Y,I•a y 15"BI1 "BIRCHI
it vi
S RAW WA DLE&6"OPAQUE CONSTRUCTION FENCING �i o
6o S.F.TO ENCROACH INTO REAR SETBACK `";
1200 S.F.OF REAR YARD MAINTAINED
. ao . ao�. .°ao�.°ao . ao�.°o•o�.°ao�.°as . as . as . as . as�.°as�.°o °�•o . as . as . o•a�.°aA�.°aA�.°as . as�.°o a . as�.°o•a�.°as . as .
.'o D.'o D.'o D.'o D.'o D.'° D.'° D.'° D.'o D.'o D.'
� —-—-—-—-—-—- ----------—-—-—-—-— ------- --, •a °°^a °°° °°° °°°a °°°a °°° °°° °°° °°^a °°^a °°°a °°° °°° I� ° °°° °°° °.SIDEWALK'°'
°o �.°aa .°aa °aa .°aa .°aa °aa .°o �.° .°aa .°aa .°aD °aa
ii I CURB AND GUTTER
I = I I
591 S.F. tog S.F. 400 S.F.
I
SHADOW HILL LANE
I I
I I
I I
I I
I DRAWN
MM
CHECKED
MM
DATE
10/24/2023
SCALE
AS SHOWN
SITE LAN JOB NO.
II � II �����: �/� II — V-011
PAGsE:
SCALE: Ii8 = � -03/17