Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
R-2023-035 - Site Plan and Massing Diagram
�� 1`r GENERAL NOTES DESIGN TEAM CONTACT; PROJECT SCOPE: PROJECT INFORMATION IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND SUBCONTRACTORS TO CHECK SURVEY: GEOTECH: ARCHITECT: STRUCTURAL: NEW CONSTRUCTION OF TWO STORY HOME WITH ATTACHED ADU. Yun Sun AND VERIFY ALL DIMENSIONS AND CONDITIONS INDICATED ON THESE DRAWINGS AND Zhen's Land Surveying Corp. CAPER ENGINEERING INC. Yin Su Wesley Liu REPLACE 4" SEWER LINE AND INSTALL CLEAN OUT. REPLACE E WATER LINE. ADD FIRE SPRINKLER. PROPERTY: 877 Betlin Ave, MAKE KNOWN ANY DISCREPANCIES PRIOR TO COMMENCING THEIR WORK L.S.#9653 SW Design y ( ) THESE DRAWINGS AREA INTENDED FOR USE IN A NEGOTIATED CONSTRUCTION PO BOX 14198,FREMONT,CA 94539 g Wesley Liu Engineering,Inc. PROPOSED MAIN RES: Cupertino, CA 95014 CONTRACT AND, THEREFORE, MAY NOT SPECIFICALLY DETAIL OR SPECIFY MATERIAL San Mateo,CA Tel:(408)257-8252 Fax:(408)257-8959 yinsu2002@gmail.com 7246 Sharon Drive#0 2,251 SF LIVING AREA (4 BEDROOMS AND 3 BATHROOMS )AND 450 SF GARAGE AREA APN: 369-27-027 AND/OR MANUFACTURERS. THE CONTRACTOR SHALL PROVIDE ALL SAMPLES AND OR (415)802-9945 650-265-8676 San Jose,CA95129 PROPOSED ATTACHED ADU: OWNER: Yun Sun CUTS AS REQUIRED TO ASSIST OWNER OR HIS AGENT IN MAKING MATERIAL zhen.wang588@gmail.com 408-973-1839 2 BEDROOMS AND 2 BATHROOMS )) LOT SIZE: 6,003 SF (OWNER) SELECTIONS. FOR THE PURPOSE OF ESTIMATING, THE CONTRACTORS SHALL USE THE 799 SF LIVING AREA MATERIALS SELECTED BY THE OWNER, OR IN ABSENCE OF SAME, HE SHALL PROVIDE LOT ZONING: R-1-6 AN ALLOWANCE AMOUNT AND SO CONDITION ANY COST ESTIMATE.. ALL MATERIALS THE HORIZONTAL CONTROL PLAN IS PREPARED BASED ON THE BOUNDARY SURVEY PREPARED BY THE PROJECT'S LICENSED SURVEYOR. TYPE OF CONSTRUCTION: TYPE V-B, FULL SPRINKLERED SPECIFIED IN THESE DRAWINGS SHALL BE INCLUDED IN SUCH ESTIMATE PER SECTION 16.06.100 OF THE CUPERTINO MUNICIPAL CODE, OCCUPANCY: R-3 & U NO GUARANTEE OF QUALITY OF CONSTRUCTION IS IMPLIED OR INTENDED BY THE ROOFING MATERIAL MUST BE CLASS A BURN FIRE RATING. Address: ARCHITECTURAL DOCUMENTS, AND THE CONTRACTOR SHALL ASSUME FULL PUBLIC WORKS'NOTES: LAND USE DESIGNATION: LOW DENSITY RESIDENTIAL 1-5 DU/AC . RESPONSIBILITY FOR ANY OR ALL CONSTRUCTION DEFICIENCIES. 1)APPROVAL OF THESE PLANS DOES NOT RELEASE THE OWNER AND/OR CONTRACTOR OF THE RESPONSIBILITY FOR THE CORRECTIONS OF MISTAKES, ( ) 877 Betlin Ave, THE GENERAL CONTRACTOR SHALL HOLD HARMLESS, INDEMNIFY AND DEFEND THE ERRORS,OR OMISSIONS CONTAINED THEREIN. IF DURING THE COURSE OF CONSTRUCTING IMPROVEMENTS,PUBLIC INTEREST REQUIRES A DESIGNER FROM ANY ACTION INITIATED BY THE INITIAL OWNER OR ANY SUBSEQUENT MODIFICATION OF/OR A DEPARTURE FROM THE CITY OF CUPERTINO SPECIFICATION OR THESE IMPROVEMENT PLANS,THE CITY ENGINEER SHALL HAVE EXISTING LIVING AREA: 1,472 SF. OWNERS FOR CONSTRUCTION DEFICIENCIES, MODIFICATIONS OR SUCH CONDITIONS THE AUTHORITY TO REQUIRE SUCH MODIFICATION OR DEPARTURE AND TO SPECIFY THE MANNER IN WHICH THE SAME IS TO BE COMPLETED,AT THE EXISTING GARAGE AREA: 455 SF. WHICH MAY BE BEYOND THE CONTROL OF THE DESIGNER. SOLE EXPENSE OF THE OWNER AND/OR CONTRACTOR. Cupertino, CA 95014 ALL WORK SHALL COMPLY WITH APPLICABLE CODES AND TRADE STANDARDS WHICH 2)CONTACT PUBLIC WORKS,(408)777-3104, FOR INSPECTION OF GRADING,STORM DRAINAGE,AND PUBLIC IMPROVEMENTS. PROPOSED TOTAL LIVING AREA: 2,241 SF. GOVERN EACH PHASE OF WORK, INCLUDING BUT NOT LIMITED TO: UNIFORM BUILDING 3)ALL PUBLIC IMPROVEMENTS MUST BE COMPLETED PRIOR TO OCCUPANCY. PROPOSED GARAGE AREA: 430 SF. CODE (UBC), UNIFORM MECHANICAL CODE (UMC), NATIONAL ELECTRICAL CODE (NEC), 4)CONTRACTOR IS RESPONSIBLE FOR DUST CONTROL AND ENSURING THE AREA ADJACENT TO THE WORK IS LEFT IN A CLEAN CONDITION. PROPOSED F.A.R: 2,671 SF/6,003 SF=44.5%. NATIONAL PLUMBING CODE (NPC), AND ALL APPLICABLE LOCAL CODES AND 5)CONTRACTOR SHALL REVIEW CITY DETAIL 6-4 ON TREE PROTECTION PRIOR TO ACCOMPLISHING ANY WORK OR REMOVING ANY TREES. LEGISLATION. 6)UTILIZE BEST MANAGEMENT PRACTICES(BMP'S),AS REQUIRED BY THE STATE WATER RESOURCES CONTROL BOARD,FOR ANY ACTIVITY,WHICH PROPOSED ATTACHED ADU: 799 SF THE CONTRACTOR SHALL REVIEW AND RECORD THE CONDITIONS OF ALL EXISTING DISTURBS THE SOIL. PROPOSED LOT COVERAGE: 2,408 SF/6,003 SF=40% (SEE CALCULATION ON A0.1c ) Email: SITE IMPROVEMENTS INCLUDING PAVED AREAS. HE SHALL MAKE KNOWN ALL 7)A WORK SCHEDULE OF GRADING AND EROSION&SEDIMENT CONTROL PLAN SHALL BE PROVIDED TO THE CITY ENGINEER BY AUGUST 15. NO HILLSIDE EXISTING DAMAGED OR DISREPAIRED ITEMS AND CONDITIONS THAT MAY WORSEN GRADING SHALL BE PERFORMED BETWEEN OCTOBER 1 AND APRIL 15. VICINITY MAP SITE DUE TO THE CONSTRUCTION. ALL ITEMS IN GOOD CONDITION SHALL BE MAINTAIN IN 8)TO INITIATE RELEASE OF BONDS,CONTACT THE PUBLIC WORKS INSPECTOR FOR FINAL INSPECTION. cath c Ug@g mai 1.com THEIR PRESENT CONDITION AND ANY REPAIR OR DAMAGE WHICH OCCURS DURING 9)ALL DOWNSPOUTS TO BE RELEASED TO THE GROUND SURFACE,DIRECTED AWAY FROM BUILDING FOUNDATIONS AND DIRECTED TO LANDSCAPED Serre.P k CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. AREAS. r, i Santa Clara CentralI 10)PRIOR TO BEGINNING ANY WORK WITHIN THE PUBLIC RIGHT OF WAY,THE CONTRACTOR WILL BE RESPONSIBLE FOR PULLING AN ENCROACHMENT WOO LAND % CONTRACTOR SHALL THOROUGHLY EXAMINE THE SITE AND SATISFY HIMSELF AS OF ACGHLANDE °`unohFRn V EIGMBORs +KYo-PnPle'a HIGHLANDS -Sun yv a Sh pal': THE CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED. THE CONTRACTOR PERMIT FROM THE PUBLIC WORKS DEPARTMENT. SITE PLAN LEGEND: Trade„nes® ayele p= ,nod °9Raneh arket® Kai-Permanent, - SHALL VERIFY AT THE SITE ALL MEASUREMENTS AFFECTING HIS WORK AND SHALL BE PRIOR TO ROUGH FRAMING INSPECTION OR PRIOR TO ANY WORK TO COMMENCE WITHIN THE PUBLIC RIGHT OF WAY,WHICHEVER COMES FIRST,THE _ \ - 5 tCI ra Meaoal Ctr� RESPONSIBLE FOR THE CORRECTNESS OF SAME. NO EXTRA COMPENSATION WILL BE OWNER AND/OR THE CONTRACTOR SHALL OBTAIN AN ENCROACHMENT PERMIT.CONTACT JO ANNE JOHNSON AT(408)777 3245 FOR REQUIREMENTS P.U.E EASEMENT G3PacePreserse A°°�;o,Ca„e ho Sen Antonlaf - , AND PERMIT.ALL ENCROACHMENT PERMITS REQUIRE A CERTIFICATE OF LIABILITY INSURANCE AND A SEPARATE ENDORSEMENT NAMING THE CITY OF Apple Infln M1e Leap ALLOWED TO THE CONTRACTOR FOR THE EXPENSES DUE TO HIS NEGLECT TO EXAMINE OR FAILURE TO DISCOVER CONDITIONS WHICH MAY AFFECT HIS WORK. CUPERTINO AS ADDITIONAL INSURED AS WELL AS A VALID CONTRACTOR LICENSE(NOTE:LICENSE B CONTRACTORS ARE ONLY PERMITTED TO PERFORM ��� " Mery c ALL NEW INTERIOR PAINT COLOR, FLOOR, WALLS AND CEILING FINISHES SHALL BE WORK ON-SITE AND WILL NOT BE PERMITTED TO PERFORM WORK IN THE PUBLIC RIGHT OF WAY). }\ � W.C.E EASEMENT $ MertiPa Marina FaoU M. St,-t Cupertino_ '� o SELECTED BY OWNER AT THE TIME WHEN IT IS NECESSARY FOR THE COMPLETION OF REMOVE AND REPLACE BROKEN AND/OR UPLIFTED SIDEWALK,CURB AND GUTTER. ° ® 0 lc o OWNER HAS THE OPTION TO USE EXISTING ROLLED CURB OR INSTALL A NEW DRIVEWAY DRAINAGE DIRECTION MIN SLOPE 2/o r�rsRa De Anza Cupe ino Mamkai Mar et® m T(I W &MoreQ N th"rh PROVIDE MIN.3'OF LANDSCAPE STRIP ALONG BOTH SIDE YARDS. IMPERVIOUS AND 5°/ LANDSCAPE AWAY k `II 9 Y DAL°LRT THE PROJECT. ( ) ° ( ) A'4 LOMA LINnA ALL PUBLIC IMPROVEMENTS SHALL BE MADE IN ACCORDANCE WITH THE LATEST FROM BUILIDNG 0 ® - CITY TO PREPARE A QUITCLAIM DEED FOR WAIVING OF THE UNDERGROUND WATER RIGHTS FOR THE OWNER TO SIGN IN FRONT OF A NOTARY. Mnota =-IghSchn 1 "kP1® ADOPTED CITY STANDARDS. THE STORING OF GOODS AND MATERIALS ON SIDEWALK 0 c eedePk RINCUNA�A mm, Ms°wa^^asa,o Fl AND/OR STREET WALL NOT BE ALLOWED UNLESS THE CONTRACTOR HAS APPLIED WALL MTD. OUTDOOR LIGHT FIXTURE - M - ,Tr AND SECURED A SPECIAL PERMIT WHICH ALLOW SUCH STORAGE TO BE PLACED. LED (w/MOTION SENSOR & PHOTO CONTROL). d The He-DePet s,RpAgKRR. SEE SPEC: BLACK DARK SKY OUTDOOR WALL LIGHT "s'r ,Park a� I,9Hunanl,npres=Inn • • • • TREE PROTECTION FENCE RCC_ "Man San Jose Da A.. f� Stevens Creek © JOAOUIN MILLER r LY x"�� CiDUnt,'Palk 58r_Oar (J� _ G ti--Park Lynbro&g1.9ahoolQ WEST sQrt'dos>= (E)6' HIGH ,r I, COUNTRY LANE Fr. (E)6" FRUIT TREE TO (E)5" FRUIT TREE REDWOOD 1 0 - '� RAINBOW DROOKVALE � REMAIN TO REMAIN FENCE `"ANTE` HAT""',,_A %I - - - - -1 - -- - -___ - - / - - - - - ' - • - - \ Westgate Center Q Designer: Yin Su �NLIO T insu2002 mail.com TREE PROTECTION FENCE APPLICABLE CODES y@gmail.com APPLICABLE J • b 2022 CALIFORNIA RESIDENTIAL CODE 2022 CALIFORNIA BUILDING CODE D ° • 2022 CALIFORNIA ELECTRIC CODE CALGREEN NOTES: pb`� 2022 CALIFORNIA MECHANICAL CODE 4.106.2-Storm water drainage and retention during construction(less than one acre). Newly constructed projects and 2022 CALIFORNIA PLUMBING CODE D D o • . additions which disturb less than one acre of land shall prevent the pollution of stormwater runoff from the construction activities N ATTACHED ADU (E)6' HIGH D REDWOOD 2022 CALIFORNIA ENERGY CODE (PART 6 OF TITLE 24) through one or more of the following measures: ° J FENCE 2022 CALIFORNIA FIRE CODE(PART 9 OF TITLE 24) 4.106.2.1 - Local ordinance. Comply with a lawfully enacted storm-water management and/or erosion control • 01 • - • • • • • • • • - ordinance. Q 2022 CALIFORNIA GREEN BUILDING CODE 4.106.2.2 - Best Management Practices (BMP). Prevent the loss of soil through wind or water erosion by D + CUPERTINO MUNICIPAL CODE implementing an effective combination of erosion and sediment control and good house-keeping BMP. 5'-0'I 4'-0" A4.106.2.3 Topsoil protection.Topsoil must be stockpiled for reuse in a designated area and covered for protected from erosion. GROUND F OOR SI SETBACK SYMBOLS 4.106.3 Grading and Paving. Surface water shall be directed away from all buildings. The contractor shall ensure the prevention of water entering the buildings using swales, French drains, or other approved measures that will keep surface water away from V1 KEY PLAN buildings. D A4.106.4 Water permeable surfaces. The site plan shall show a breakdown matrix of the square footage entitled "Water GRID LINE NUMBER OR Permeable Surface Area"of all site paving elements and individually show if the paving material is permeable or not(paving for �Y GRID LINE parking, walking or patio surfaces apply). The matrix must show calculations reflecting a minimum of 30%for Tier 2 projects. 33"x33"SKYLIG ' LETTER (CGBC A4.106.4) A4.106.2.2 Soil protection. The effort of development on building sites is evaluated and the soil is protected by one or more of the following: (a) Natural drainage patterns are evaluated and erosion controls are implemented to minimize erosion during I-0 22N 60"SKYLIGHT, �'� 1 DETAIL NUMBER construction and after occupancy, (b)Site access is accomplished minimizing the amount of cut and fill needed to install access TYP DETAIL roads and driveways, (c)As allowed by other parts of the code, underground construction activities are coordinated to utilize the I A 501 SHEET WHERE DETAIL IS DRAWN. same trench, minimize the amount of time the disturbed soil is exposed and the soil is replaced using accepted compaction (E)6' HIGH I SAME DISCIPLINE methods. REDWOOD 4.303.1.1 -Water closets shall not exceed 1.28gpf and shall be EPA WaterSense Certified FENCE 4.303.1.3.1 -Single showerheads shall not exceed 1.8gpm @80psi and shall be EPA WaterSense Certified 1 SECTION NUMBER SECTION 4.303.1.4.1 Residential lavatory faucets shall not exceed 1.2gpm @60psi and shall not be less than 0.8gpm @20psi. A 301 SHEET WHERE SECTION IS DRAWN. 4.303.1.4.3 Metering faucets installed metering faucets in residential buildings shall not deliver more than 0.25 gallons per cycle. SAME DISCIPLINE Requirements shall be indicated on the plumbing fixture schedule. (4.303.1.4.3) 4.303.2- Plumbing fixtures and fittings shall meet the standards referenced in Table 1401.1 of the California Plumbing Code. 22°x33° 4.303.1.4.4- Kitchen faucets shall not exceed 1.5gpm @60psi SKYLIGHT 1 ELEVATION NUMBER A4.303.3-Appliances. Water saving dishwasher appliances will be used on the project. Install a minimum of one qualified SHEET WHERE ELEVATION IS ELEVATION ENERGY STAR appliance with maximum water use as follows: 33°x33° A 0.3 DRAWN. SAME DISCIPLINE 1. Standard Dishwashers-4.25 gallons per cycle. SKYLIGHT 2. Compact dishwasher-3.5 gallons per cycle. 0 5'-0" 3. Clothes washers-water factor of 6 gallons per cubic feet of drum capacity. DELTA DRAWING PIPER FLID R SIDE SETB C 1 4.406.1 -Rodent proofing. The contractor shall rodent proof annular spaces around pipes, electric cables, conduits or other Outdoor Wall Lights SEE DESCRIPTION BLOCK REVISION openings in plates at exterior walls by closing such openings with cement mortar, concrete masonry. ON SAME SHEET FOR DATE PAMC 16.14.260/4.408.1 -Enhanced Construction Waste Reduction (80%Diversion). Any mixed recyclables that are sent to 26°xsa° 15'-0" & DESCRIPTION mixed-waste recycling facilities shall include a qualified third party verified facility average diversion rate of at least 80%. SKYLIG"\ ' Verification of diversion rates shall meet minimum certification eligibility guidelines, acceptable to the local enforcing agency. UPPER FLOOR SIDE SETBACK O KEYED NOTES SEE DESCRIPTION 4.408.2-Green Halo Management. The waste management plan shall be uploaded to the Green Halo Tracking System. 1 KEYNOTE zz��x33°, LIST ON SAME SHEET PLAN CHECK II 4.408.3-Waste management company. The contractor shall utilize a waste management company approved by the City of SKYLIG" 9 � Palo Alto that can provide verifiable verifiable documentation that the percentage of waste material diverted from the landfill complies 10,-�„ �O FILLED LINE INDICATES PLANNING RESUBMITTAL 08.28.2023 with PAMC 16.14.260 (80%waste Reduction) 871 BETL N 877 BETLIN o D PLAN NORTH NORTH 4.410.1 -Operation and Maintenance Manual.At the time of Final Inspection, a manual in a format acceptable to the City GR D FLOOR$I SE BACK 885 BETLIN shall be laced in the home. The manual shall provide operation and maintenance instructions for all equipment and Q� Portfolio 1-Light 7-in Matte p p pI DASHED ARROW INDICATES ARROW NO. DESCRIPTION DATE appliances, HVAC equipment, PV systems, EV chargers, drainage systems including gutters and downspouts, irrigation V p ! Black Dark Sky Outdoor Wall Light TRUE NORTH systems, water reuse systems; local utility, water and waste recovery providers contact information; recycling programs and • . Black finish outdoorwall light helps to keep the night skies dark locations; public transportation; how the occupant an maintain the relative humidity between 30 and 60 percent; a copy of all while providing Il htwhere ❑u need it special inspection verifications required by the City. ° !� p 9 9 y D RAW I N G INDEX A4.403.2-Low-carbon Concrete Requirements. • . Black shade compatible with the fixture perfectly S SK (1) Cement and Embodied Carbon Limit Allowances. Cement or Embodied Carbon limits shown in Table A4.403.2.3 can be rl increased by 30% for concretes demonstrated to the Building Official as requiring high early strength. Such concretes could • • - - r • o° ° AO.O SITE PLAN include, but are not limited to, precast, prestressed concrete; beams and slabs above grade; and shotcrete SURVEY PROPERTY SURVEY (2)Approved Cements. The maximum cement content may be increased proportionately above the tabulated value when Y -  - p using an approved cement, or blended cement, demonstrated by approved EPD to have a plant-specific EPD lower than Q - (N)6' HIGH NOTE: L1 LANDSCAPE LAYOUT 1040 kg CO2e/metric ton. The increase in allowable cement content would be (1040/plant=specific EPD) %. - _ m a -a ° REDWOOD A4.403.2.3.2 Cement Limit Method - Mix. Cement content of a concrete mix using this method shall not exceed the value d. - ��° - D L2 PLANTING PLAN FENCE W/GATE 1. PROVIDE POSITIVE DRAINAGE shown in the Table A4.403.2.3. Use of this method is limited to concrete with specified compressive strength not exceeding N 6' HIG o ° °$° ° y p TO ROOF DRAINS FROM ALL ( ) ° v Front and impervious area calculation: L3 IRRIGATION PLAN 5,000 psi. REDWO D } in - a Q a°ao° Total front yard area:58x20= 1,160 sf A4.403.2.3.3 Cement Limit Method - Project. Total cement content shall be based on total cement usage of all concrete mix FENCE /GATE _ m o Q D o PARTS OF THE ROOF. L4 LANDSCAPE SCHEDULE 5' 0" ° - a 50/D of the front and=580sf designs within the same project. Total cement content for a project shall not exceed the value calculated according to w ° w Y 65 SF Y ° - � 24'°6 a _ e Driveway area in the front yard:467 sf AO.Od DEMOLITION PLAN Equation A4.403.2.3.3. (N)WALKWAY: U ° Y ° O Q ° " - °o Walkwa area in the front ard:65 sf 2. D.S.c INDICATES 2 x3 26 A4.405.3.1 -Recycled content(10%).The RCV shall not be less than 10 percent of the total material cost of the project. O m a z Y AO.1 a PROPOSED GROUND FLOOR PLAN w Y Required total RCV(dollars)= Total Material Cost dollars x 10 percent(equation A4. 4-1 SEE LANDSCAPE PLAN o � a -' O o ° Total imperious area in the front yard: GA. G.I. DOWNSPOUTS PROJECT NO. q ( ) (dollars) p ( q ) Q ° 467+65=532 sf<580 sf LOCATED AS SHOWN. AO.1 b PROPOSED UPPER FLOOR PLAN w N l- a ' ° w N o Front Yard Impervious Area Limitation:Please indicate the w z a ° a, O w AO.1 c AREA DIAGRAM / MATERIAL BOARD New Front Yard Tree be 24- O a Q > percentage of front yard impervious area. Lots equal to or less 3. PROVIDES 5"-26 GA. G.I. SCALE 1/8" - 1'-0° A4.407.3-Flashing Details.Architect to provide flashing details on the building plans which comply with accepted industry inch box or larger,with a �a p than 60'in width shall have no more than 50%impervious AO.2a BUILDING ELEVATIONS minimum height of ao ° ¢ a Q OGEE GUTTER OVER 2x8 standards or manufacturer's instructions in the following locations: Around windows and doors; roof valleys; deck cam, ° c7 area in the front yard(CMC Section 19.124.030). A0.2b BUILDING ELEVATIONS shall be planted in front of g b SPRUCE FASCIABLARD-TYP. connections; chimneys to roof connections; drip caps as appropriate new second stories in the a: 20'-0" - T-0" Front Yard:At least 50%of the front yard of any project TITLE A4.407.4-Material Protection. Buildingmaterials delivered to the construction site shall be protected from rain and other front yard setback area(CMC D approved pursuant to Chapter 19.28.150 shall be occupied b p ° p p P Y A0.4 BUILDING SECTIONS Section fs.zs.t2o). DRIVEWAY WIDTHlandscaping(' p ) 4. ROOF PITCH TO BE 4:12 AS SITE PLAN sources of moisture. AD Le.,not hardsca ed . BMP CUPERTINO BEST MANAGEMENT PLAN 4.504.1 -Covering of duct openings, protection of mechanical equipment during construction all duct and other _ _ _ _ = _ = NOTED 77 related air distribution component opening shall be covered to reduce the amount of dust, water, and debris which may D p ° ° ° enter the building. - 4.504.2.1 -Adhesives, sealants and caulks. The contractor shall familiarize him-/herself with CALGreen Tables 4.504.1 & ° ° ° D 5. ROOF MATERIAL TO BE CLASS 2 (Adhesive/Sealant VOC Limits)and use only those material the comply with the allowable VOC limits. ° ° ° ° D • • ° ° ° ° ° D °t7 ° ° A TILE ROOF OVER 30# FELT- 4.504.2.2-Paints and Coatings. The contractor shall familiarize him4herself with CALGreen Table 4.504.3 (VOC Content a D D °p TYP. Limits for Architectural Coatings)and use only those material the comply with the allowable VOC limits. • ° 4.504.2.3-Aerosol paints and coatings.Aerosol paints and coatings shall meet the requirements of Sections 94522(a) o • s ° p ° 6. PROVIDE NECESSARY (2), 94522(e)(1), and (f)(1)of CA Code of Regulations, Title 17 commencing with Section 94520 (4.504.2.3) • • D o ° TREE PROTECTION FENCE FLASHING AT ALL ROOF AND 4.504.5-Composite Wood Products. The contractor shall use composite wood products made with either California Air % D p D Resources Board approved no-added formaldehyde (NAF) resins or ultra-low emitting formaldehyde (ULEF) resins. WALL CONNECTIONS AS 4.505.3-Moisture Content of Wood Products. Building material with visible water damage shall not be installed. Wall REQUIRED. . and Floor framing shall not be enclosed if the moisture content exceeds 19%. The materials shall be tested prior to ' t installation of sheetrock. (E)6" CABBAGE TREE TO PROPOSED SITE/ ROOF PLAN 7. PROVIDE 3/4"THICK T&G 4.506.1 -Bathroom Exhaust Fans. Bathroom exhaust fans shall be ENERGY STAR compliance and ducted to terminate REMAIN 1/8 = 11_0111PLANKS @ ROOF OVERHANG outside of the building. Fans shall be controlled by a humidity controller. AREA. 2013