Loading...
R-2023-038, RM-2023-035 - A0.1 SITE PLANCommunity Development Department Planning Division — Cupertino cueeRTINQ APPROVED Case # R-2023-038, Approval Body: Director / Staff Approval ate 03/14/24 Signature _ M Group Case Manager 5'-0" 617.0 /I m Q 20 w m J / I \ o Cf) I I 0 28 / m / m I I � I I 20 �^ I\ I \ I/ 3 'I / / I� I I \ J I I I I O L6 0 I t 23 204 24'-2" CD o / \ \ 00 (-' � 7 I I I 16 r \ 2 .9 / / W W W W 23 _i I I 1 I SS - SS ss I `04 �► _ NEW ADU J I s 799SF s/ • �' 17 23 / 14 I 19 15 4j+ \DECK ,100SF� L PATIO I ti .. 206$F I\ tix, Lx \ / I J4 U 2ND I 1�1 23 J \ / FLOQR 03 \ —LIVING?- I /I e I 15— 0" AREA 2ND FLR. / 836SF I SIDE S.B. 15'-0" 2ND FLR. SIDE S.B. I ............. 4 3\ +....... / I F ... ...... ...1.........204 4 I + 203 g�/ \ I ............ L'.'.'.'.'.'.' \ I 1 4GARAGE \ �204. 459SF l j 28 \ ..................... ..... \ 1ST L00 / 13.5SF \ IVIN I 1,1 SF J.... .13.5SF .. 26 _ L 21 ............ j I 26 ................... --6 m - vi — — — 0 ~ z 0 z AY "NEW�DR�1\2, 15 15 19 y 23 Ln L_ _j 400SF COVERED AT FRONT YARD < 11 I 13 N � � m 28 00% FONT YARD 1,020SF) 12 I o w SS `" CONCRETE DRIVEWAY z 10 O O L - 51.00' P.L / 27 202.8 31 \ S •� �g4.4 Lij VN ue � I M Cn w m O Q IZ m O N v O O Q m Q w m � N p w w O o m O m m m 0 m / 5' / 22 \ T / L . \ 3.9' I o N \ / 0 o \ L C E o 4 -r, O z • 03 E Cn np WMx2 LOT 7 46 48-M- N: 375-34-054 -------------------------------------------------------------------- --------------------------- CONCRETE ROLLED CURB, GUTTER & SIDEWAL HUNTER WAY SITE PLAN AND HORIZONTAL CONTROL PLAN NOTE: THE HORIZONTAL CONTROL PLAN IS PREPARED BASED ON THE BOUNDARY SURVEY PREPARED BY THE PROJECT'S LICENSED SURVEYOR. 1 /8" = 1'-0" ........ ...................... ....... ....r. ... ........ ..... ...c u A. PROPERTY OWNER SHALL RECORD A ... :: :.:.:.: COVENANT ON THE PROPERTY FOR THE NEW TREES/SHRUBS PLANTED FOR PURPOSE OF REQUIRED REPLACEMENT TREES, PRIVACY PROTECTION, AND S*.T U'.*D i.'.o.'; .. ... ... .. ....� REQUIRED FROM YARD TREE. B. FOLLOWING COMPLETION OF Q ..... .......... ..._u CONSTRUCTION, AN AFFIDAVIT FROM AN . ISA—CERTIFIED ARBORIST SHALL BE ...................a PROVIDED COMFIRMING THAT THE NEW . . . . . . . . .i TREES HAVE BEEN PLANTED PROPERLY P: 4.......... F. go8:s7..... . ....:.:.:...� AND ACCORDING TO PLAN. C. A PLANNING INSPECTION IS REQUIRED Project: TO VERIFY EXTERIOR Ip Residence MATERIALS/FINISHES, TREES, New Custom Homes LANDSCAPING AND SITE WORK. 18851 Hunter Way Cupertino, CA 95014 OME MCEW MUM-5 Applicant/Owner: O (E) ROLL CURB TO REMAIN AS IS (� (N) IMPERVIOUS CONC. PAVER DRIVE WAY LESS THAN Mr. Anson Ip 50% FRONT YARD AREA. O 24" ROOF OVER HANG, TOTAL AREA IS 518SF 18851 Hunter Way ® (N) 14" WATER LINE Cupertino, CA 95014 O REPLACE (E) J" WATER METER WITH (N) WATER METER PER FIRE SPRINKLER PLAN. (N) WATER METER SHALL BE (408) 221-7887 Ai. Development. us@gmail.com OUT SIDE OF DRIVE WAY APPROACH. © WATER PIPE SPLIT FROM OUT SIDE ONE CONNECT TO MAIN HOUSE AND ONE CONNECT TO ADU. ALL WATER PIPE SHALL BE COPPER OR SCHEDULE 40. O 400A ELECT. PANEL INCLUDING 2 ELECT. METERS. ONE METER SERVICE MAIN HOUSE AND THE OTHER METER WILL Architect: SERVE THE ADU. ® OVER HEAD UTILITIES LINE STUDIO 61 ARCHITECTS, Inc. O 10 ROOF OVER HANG SET BACK INSTALL NEW C.O. AT PROPERTY LINE PER CITY OF SUNNYVALE STANDARD DETAIL 15A 12480 Saratoga Ave. Saratoga, CA 95070 T: (408) 892.5020 11 (N) CLEAN OUT SAME SIZE WITH SEWER LATERAL, MAX. 24" FROM BUILDING FOOT PRINT. SHALL BE AS SAME SIZE OF S61ARCHITECT@GMAIL.COM THE SEWER LATERAL 12 (N) 4" ABS SEWER LINE W/ MIN. 2% SLOPE TO STREET 13 O 14 3" ABS LATERAL LEADING TO ADU CONNECTED TO SEWER LATERAL FROM THE FRONT YARD. (N) HOSE BIBBS W/ NON —REMOVABLE TYPE BACKFLOW PREVENTION DEVICE SED ARC �G�'� OK L. y/TF� 'A 15 HINKLEY LIGHTING, VOLTAGE 120v, WATT 1-50w, MODEL SHELTER, EXTRA SMALL WALL MOUNT LANTERN 1326BK—LL. SEE SPECS ON PAGE A0.4 NO. C29889 REN. 2/28/25 16 CONDENSER AC UNIT WITH 68 dBA, COVER WITH SOUND BLANKET TO REDUCE TO 65 dBA. INSTALL UNIT MIN. 13FT FROM PROPERTY LINE. SEE SPECS ON PAGE A0.4. SEE OF CAL\ UPLOADED "SR—WORKSHEET-1UNITS.PDF" j ] CONDENSER AC UNIT WITH 68 dBA, COVER WITH SOUND BLANKET TO REDUCE TO 65 dBA. INSTALL UNIT MIN. 18FT FROM PROPERTY LINE. SEE SPECS ON PAGE A0.4. SEE 18 O UPLOADED "SR—WORKSHEET-2UNITS.PDF" (N) TREE, SEE PRIVACY PLAN ON A0.2 AND LANDSCAPE Structure Engineer: PLAN L1 FOR TYPE OF TREE AND LOCATION OF TREE. 19 (N) DOWN SPOUT WITH PROVIDE DIRECT ROOF RUNOFF AND ON —SITE SURFACE DRAINAGE TO LANDSCAPED AREAS OR GRASS SWALES FOR INFILTRATION TO THE GREATEST DEGREE POSSIBLE 20 LANDING WITH 18" HIGH FROM GRADE SHALL HAVE 10'-0" MIN. SET BACK 21 OPEN TO SKY. NO ROOF ABOVE 22 (N) FRONT YARD TREE — SEE LANDSCAPE PLAN L1, MIN. 24" BOX OR LARGER, WITH A MIN. HEIGHT 8'-0". 23 GRADE TO SLOPE AWAY FROM STRUCTURE MIN. OF 5% WITHIN THE 1ST 10—FEET OF STRUCTURE. IF IMPERVIOUS SURFACES ARE WITHIN THE FIRST 10—FEET OF THE BUILDING, A MIN. OF 2% AWAY FROM STRUCTURE IS ALLOWED. 24 (N) 6'-0" MAX. HIGH REDWOOD FENCE AND/OR GATE 25 (E) 6'-0" MAX. HIGH REDWOOD FENCE ALONG PROPERTY LINE. 26 BAY WINDOW W/ 24" MIN. HIGH WINDOW SEAT. NOT COUNT TOWARD F.A.R. 27 PRIOR TO ISSUANCE OF BUILDING PERMIT, PROPERTY OWNER CAN APPLY FOR A REVOCABLE ENCROACHMENT PERMIT FOR THE PROPOSED PRIVATE IMPROVEMENTS. BY SIGNING THE REVOCABLE ENCROACHMENT PERMIT, THE OWNER AGREES AND SHALL MAINTAIN ALL PRIVATE AND NON—STANDARD IMPROVEMENTS WITHIN THE PUBLIC RIGHT—OF—WAY. FURTHERMORE, UPON CITY'S REQUEST, THE OWNER AGREES TO Plan Check Comment 12.27.23 REMOVE, RELOCATE AND/OR MODIFY THESE IMPROVEMENTS AT OWNER'S SOLE EXPENSE. IF AND WHEN UTILITY COMPANIES Plan Check Comment 8.16.23 ARE REQUIRED TO PERFORM WORK WITHIN THE AREA, THE CITY MAY REQUIRE UTILITY COMPANIES TO REMOVE OR REPLACE THESE IMPROVEMENTS IN KIND. HOWEVER, CITY AND NO. Revision Date UTILITY COMPANIES WILL NOT PROVIDE WARRANTIES ON THE REPLACED IMPROVEMENTS. THE OWNER ACCEPTS ALL LIABILITY Drawn By: Date: FOR THESE IMPROVEMENTS AND AGREES TO DISCLOSE THE NATURE OF THIS ENCROACHMENT PERMIT WITH POTENTIAL FLH 12.27.2023 BUYERS OF PROPERTY. 28 REMOVE (E) TREE — SEE LANDSCAPE PLAN ON PAGE L1 FOR TREE SIZE AND TREE NAME. SEE ALSO DEMOLITION File: 29 PLAN ON PAGE A2.0 NOT USED 2208 30 ELECTRIC FIRE PLACE FLUE, NOT COUNT TOWARD F.A.R. Issue: 31 (N) STREET TREE PER PUBLIC WORK DEPARTMENT. PLANT TREE MIN. 20' AWAY FROM FRONT YARD TREE. Date: 12.27.2023 Sheet Title: SITE PLAN Sheet No.: LQOo �