Loading...
Project Plans11.02.23 Scale Drawing No. AS SHOWN Revision A l l i d e a s , d e s i g n s a n d p l a n s i n d i c a t e d o r r e p r e s e n t e d b y t h i s a r t a r e o w n e d b y a n d r e m a i n t h e p r o p e r t y u s e d o r d i s c l o s e d t o a n y o n e o f O p e n R e m o d e l . N o p a r t s h a l l b e Title Date w i t h o u t p e r m i s s i o n o f t h e C o m p a n y. No. Date RESIDENCE REMODEL Firm Name and Contact : Architecture | Home Designs www.openremodel.com contact@openremodel.com 408.357.3043 Th i s d r a w i n g h a s b e e n p r e p a r e d f o r t h e u s e o f O p e n R e m o d e l ( O R ) C l i e n t . I t m a y n o t b e u s e d , m o d i f i e d , r e p r o d u c e d , o r r e l i e d u p o n b y t h i r d p a r t i e s , e x c e p t a s a g r e e d b y O R o r a s r e q u i r e d b y l a w . O R a c c e p t s n o r e s p o n s i b i l i t y , a n d d e n i e s a n y l i a b i l i t y w h a t s o e v e r , t o a n y p a r t y t h a t u s e s o r r e l i e s o n t h i s d r a w i n g w i t h o u t O R ' s w r i t t e n c o n s e n t . D o n o t s c a l e t h i s d o c u m e n t . O n s i t e m e a s u r e m e n t s t o b e v e r i f i e d b y t h e C o n t r a c t o r . PR O J E C T A D D R E S S : HU E Y R E S I D E N C E R E M O D E L 13 8 1 P O P P Y W A Y , CU P E R T I N O , C A 9 5 0 1 4 Design Manager: Shweta Singh PLAN CHECK REVISION106-14-24 PLAN CHECK REVISION209-20-24 COVER SHEET A1.0 Assessors Parcel No.: 366-18-030 Zoning: R1-6 Occupancy Group: R3-U (Residential) Designated land Use: Low Density (1-5 DU/Ac.) Flood Hazard: Zone X Seismic hazard: NA WUI ZONE: YES Name of Owner: Michael Huey Email of Owner: monamdeng@gmail.com Project Address: 1381 Poppy Way, Cupertino, CA 95014 Total Lot Area: 6000 Sq.Ft. Existing House Area: 1440 Sq.Ft. Existing Garage Area:430 Sq.Ft. (No Change) Existing Front Porch Area: 34 Sq.Ft. (3 Sided Covered) Existing Eave / Overhang Area: 421 Sq.Ft New Extended Area:94 Sq.Ft. Proposed Second Floor Area:647 Sq.Ft. Proposed First Floor Area: 1440 + 34 + 94 = 1568 Sq.Ft. To Second Floor Area Ratio: 647 / 1568 = 41.26% Proposed Eave / Overhang Area: 482 Sq.Ft Future Garage Expansion Area: 38 Sq.Ft Height: 21'-10" No of Floors: 2 Allowable Lot Coverage: 45% X 6000 = 2700 + 5% (For Over Hang) 5% X 6000 = 300 SQ.FT. 2700 + 300 = 3000 SQ.FT. Allowable FAR:45% X 6000 = 2700 SQ.FT. Existing Lot Coverage: 1440 + 430 + 34 + 421 = 2325 / 6000 = 38.75% Existing FAR:1440 + 430 + 34 = 1904 / 6000 = 31.73% Proposed Lot Coverage: 1440 + 430 + 34 + 94 + 482 + 38 = 2518 / 6000 = 41.97% Proposed FAR:1440 + 430 + 34 + 94 + 647 + 38 = 2683 / 6000 = 44.71% Type of Construction: V-B House is Fire Sprinklered: No Existing Bedrooms/Baths: 3 Beds / 2 Baths Proposed House Bedrooms/Baths: 4 Beds / 4 Baths GENERAL CONDITIONS/NOTES: 1. All material stored on the site shall be properly stacked and protected to prevent damage and deterioration until use. Failure to protect materials may be cause for rejection of work. 2. All construction and materials shall be as specified and/or as required by the adopted edition of the California Building Code and all local and national codes and authorities which are applicable. 3. All products, materials and finishes to be installed per manufacturers specifications - no exceptions. 4. All required Exit doors shall be operable from the inside without the use of a key or special knowledge or effort. 5. The General Contractor shall verify all dimensions and site conditions prior to commencing any work. The General Contractor shall notify the Owner of any discrepancy of these plans and specifications. 6. The General Contractor shall maintain the job site in a clean, orderly condition free of debris and litter. Each subcontractor immediately upon completion of each phase of his work shall remove all trash and debris as a result of his operation. The job site shall be left clean and swept each day by the end of work that day. 7. No portion of the work requiring a shop drawing or sample submission shall be commenced until the submission has been reviewed and acted upon by the Owner. 8. All such portions of work shall be in accordance with the reviewed shop drawings and samples. 9. The contractor shall confine operations at the site to areas permitted by law, ordinances, permits and the contract documents, and shall not unreasonably encumber the site with any material or equipment. 10. Should an error appear in specifications or drawings, or in work done by others, affecting this work, notify the designer at once for instructions as to procedure. If contractor proceeds with work affected without instructions from the designer, the contractor shall make good any resulting damage or defect. 11. Should conflict occur in or between drawings and specifications or where detail references on contract drawings have been omitted, contractor is deemed to have estimated the most expensive materials and construction involved unless he shall have asked for and obtained written decision from designer as to which method or materials will be required. 12. All patching, repairing and replacing of materials and surfaces cut or damaged in execution of work shall be done with applicable materials so that surfaces replaced will, upon completion, match surrounding similar surfaces See documents prepared by the Civil Engineering, if applicable, for all finish grades, drainage and site details. Review all site utility documents, landscape and irrigation documents prior or commencement of any under grounding or trenching. Notify the designer immediately of any discrepancies of the contract documents. 13. Construction contractor and his subcontractors agree that in accordance with generally accepted construction practices, construction contractor and his subcontractors will be required to assume sole and complete responsibility for job site conditions during the course of construction of the project,including safety of all persons and property, that this requirement shall be made to apply continuously and not limited to normal working hours, and construction contractor and his subcontractors further agree to defend, indemnify and hold design professional harmless from any and all liability, real or alleged, in connection with the performance of work on this project, except liability arising from the sole negligence of design professional as identified in item # 14 of these general conditions. 14. General Contractors, Sub-contractors, Builders, and Owner are to check all drawings for errors and omissions prior to commencement of construction. Any errors and/or omissions must be reported immediately to the designer in writing prior to commencement of construction. The designer will not take liability for any errors and/or omissions not reported immediately in writing prior to commencement of construction. The designer's liability for the total project shall not exceed one thousand dollars. 15. All screws/nails in finish woodwork to be countersunk and filled smooth with putty to match finish. 16. If the manufacturer's specifications and applicable codes are not consistent with each other, notify the designer immediately prior to commencement of any work and await direction or contractor accepts full responsibility of work 17. All gypsum board to be a minimum of 5/8" TYPE "X" sheetrock, smooth finish or as otherwise indicated on drawings. Install as needed to meet applicable codes. Use radiused corners. 18. Electrical, Mechanical, Plumbing, Fire Extinguishing System and Fire Alarm System to be Design/Build. 19. A delta ("A") symbol located at the top right hand corner of any drawing indicates that drawing has been significantly revised and should be treated as an entirely new drawing. 20. Contractor to protect all interior spaces (as required) from any weather, theft, or vandalism. 21. All walls floors and ceilings are to be finished to match existing adjacent surfaces. All new finishes and fixtures are to be approved by owner or designer, prior to installation. 22. Relocate or install new plumbing, gas, and electrical lines (as required) for the new construction. 23. Contractor to dispose of all debris at an approved dump site per all Town, County, State and Federal regulations. 24. Contractor to notify owner and designer if he suspects that any asbestos is on site and stop work immediately until authorities have proved the work to be safe. 25. Smoke detectors shall be installed in all bedrooms and halls. 26. All roof flashings to be primed and painted with rust proof paint. 27. Bidding - The contractor needs to examine all the drawings and the site conditions if they are different from the drawings, verify all the existing conditions on site and notify the designer prior to any construction Please bid for max. of 10 colors in a bid, not exceeding 4 colors in any given room at a time. 28. All wood coming in contact with concrete must be pressure treated, typical. 29. Contractor & sub—contractor's responsibility to make sure that all materials installation & craftsmanship for this project meets all applicable codes. 30. Incorporate best management practice (cbmp's) into construction plans & incorporate post construction water run—off measures into project plans in accordance with the city's urban run—off pollution prevention program. 31. All exterior plaster finish shall be 7/8" smooth cement plaster finish unless otherwise noted. 32. Plaster expansion joints should meet the following criteria or as shown on the drawings. a. no length should be greater than 18 ft. in either direction. b. no panel should exceed 144 sq. ft. for vertical applications c. no panel should exceed 100 sq. ft. for horizontal, curved, or angular sections d. no Length-to-width ratio should exceed 2 1/2 to 1 in any given panel. 33. Flashing provider to prime and paint with rust proof paint all flashings. 34. Emergency escape and rescue openings shall open directly into a public way; or to a yard or court that opens to a public way. Minimum opening is 24 inches in height and 20 inches in width with a minimum net clear opening of not less than 5.7 square feet. The net clear opening dimension shall be the result of normal operation of the opening. PROJECT INFORMATION:SHEET INDEX: FIRST FLOOR ·ADDED NEW EXTENDED AREA FOR STAIRCASE WITH DOOR AND WINDOWS. ·DEMOLISHED EXISTING CHIMNEY. ·RELOCATED EXISTING AC OUTDOOR UNIT AND ADDED NEW DUCTED MINI SPLIT AC. SECOND FLOOR: ·ADDED NEW SECOND FLOOR WITH 1 BEDROOM, 2 BATHS & LIVING AREA. LOCATION MAP SCOPE OF WORK: 2022 California Building Code 2022 California Residential Code 2022 California Electrical Code 2022 California Mechanical Code 2022 California Plumbing Code 2022 California Energy Code 2022 California Green Building Code 2022 California Fire Code Cupertino Municipal Code. COMMUNITY NOISE CONTROL: CONSTRUCTION NOISE IS LIMITED TO: ·RESIDENTIAL DAYTIME NOISE LEVELS FROM COMPLAINT SITE – 60 DBA ·NON-RESIDENTIAL DAYTIME NOISE LEVELS FROM COMPLAINT SITE – 65 DBA DAYTIME HOURS ARE DEFINED AS BEING BETWEEN THE FOLLOWING HOURS: ·WEEKDAYS – 7:00AM TO 8:00PM ·WEEKENDS – 9:00AM TO 6:00PM CONSTRUCTION, OTHER THAN STREET CONSTRUCTION GREATER THAN 750 FEET OF A RESIDENTIAL AREA, IS PROHIBITED ON HOLIDAYS, EXCEPT THAT CONSTRUCTION CONDUCTED BY A HOMEOWNER OR RESIDENT OF A SINGLE FAMILY DWELLING USING DOMESTIC CONSTRUCTION TOOLS IS ALLOWED ON HOLIDAYS BETWEEN THE HOURS OF 9:00AM TO 6:00PM. Second Floor Existing Floor Front Porch Eave / O.H.Garage SETBACK TABLE OF REQUIRED, EXISTING AND PROPOSED SETBACKS: SETBACK MINIMUM EXISTING FRONT FIRST FLOOR LEFT SIDE FIRST FLOOR PROPOSED RIGHT SIDE FIRST FLOOR LEFT SIDE SECOND FLOOR RIGHT SIDE SECOND FLOOR FRONT SECOND FLOOR REAR FIRST FLOOR REAR SECOND FLOOR 20'- 0" 25'- 0" 9'- 0" 20'- 0" 25'- 0" 10'- 0" 15'- 0" 31'- 4.5" NA 5'- 11" 24'- 7" GARAGE FRONT 23'- 7" 25'- 2" 6'- 0" 7'- 3" NA 10'- 0" 34'- 10" 27'- 3"NA DESIGN: SHWETA SINGH OPEN REMODEL PHONE: 408.357.3043 EMAIL: CONTACT@OPENREMODEL.COM STRUCTURAL ENGINEERING: TITLE 24: NOTE: THE PROPERTY OWNER SHALL RECORD A COVENANT ON THIS PROPERTY TO INFORM FUTURE PROPERTY OWNERS OF THE PRIVACY PROTECTION MEASURES AND TREE PROTECTION REQUIREMENTS CONSISTENT WITH THE R-1 ORDINANCE, FOR ALL WINDOWS WITH VIEWS INTO NEIGHBORING YARDS AND A SILL HEIGHT THAT IS 5 FEET OR LESS FROM THE SECOND STORY FINISHED FLOOR. THE PRECISE LANGUAGE WILL BE SUBJECT TO APPROVAL BY THE DIRECTOR OF COMMUNITY DEVELOPMENT. PROOF OF RECORDATION MUST BE SUBMITTED TO THE COMMUNITY DEVELOPMENT DEPARTMENT PRIOR TO FINAL OCCUPANCY OF THE RESIDENCE. APPLICABLE CODES:PROJECT DIRECTORY: ADDITIONAL COMMENTS: - STORM WATER SURFACE OR ROOF DRAINS AND OTHER GENERAL SURFACE WATER RUNOFF, SHALL NOT BE DISCHARGED TO THE SANITARY SEWER. - THE CUPERTINO SANITARY DISTRICT RECOMMENDS INSTALLING THE REQUIRED IMPROVEMENTS NEAR THE BEGINNING OF THE PROJECT IN CASE ANY UNFORESEEN ISSUES ARISE WITH THE INSTALLATIONS. - THE APPLICANT MAY POTENTIALLY BE REQUIRED TO UPGRADE THEIR SANITARY SEWER LOWER LATERAL IF THE DISTRICT FINDS THE STRUCTURAL CONDITIONS OF THE PIPE TO BE UNSATISFACTORY. FLOW RATES: PER CALIFORNIA CIVIL CODE ARTICLE 1101.4 AND CALGREEN SECTION 4.303.1, FOR ALL BUILDING ALTERATIONS OR IMPROVEMENTS TO A SINGLE-FAMILY RESIDENTIAL PROPERTY, EXISTING PLUMBING FIXTURES IN THE ENTIRE HOUSE THAT DO NOT MEET CURRENT FLOW RATES WILL NEED TO BE UPGRADED. PLEASE NOTE THE FOLLOWING ON THE APPLICABLE PLAN SHEETS. a) WATER CLOSETS WITH A FLOW RATE IN EXCESS OF 1.6 GPF WILL NEED TO BE REPLACED WITH WATER CLOSETS WITH A MAXIMUM FLOW RATE OF 1.28 GPF. b) SHOWER HEADS WITH A FLOW RATE GREATER THAN 2.5 GPM WILL NEED TO BE REPLACED WITH A MAXIMUM 1.80 GPM SHOWER HEAD. c) LAVATORY (MAX. 1.2 GPM AT 60 PSI) AND KITCHEN FAUCETS WITH A FLOW RATE GREATER THAN 2.2 GPM WILL NEED TO BE REPLACED WITH A FAUCET WITH MAXIMUM FLOW RATE OF 1.2 GPM (OR 1.8 GPM AT 60 PSI FOR KITCHEN FAUCETS). AC UNITS: NO A/C UNITS WILL BE APPROVED AS PART OF THE PLANNING PERMIT APPROVAL. PROJECT LOCATION A1.0 COVER SHEET C1.0 EXISTING SITE PLAN C2.0 PROPOSED SITE PLAN A2.0 EXIST. FLOOR AND ROOF PLANS A3.0 EXISTING ELEVATIONS A4.0 PROPOSED FIRST FLOOR PLAN A5.0 PROPOSED SECOND FLOOR PLAN A6.0 PROPOSED ROOF PLAN A7.0 PROP NORTH AND EAST ELEV A8.0 PROP SOUTH AND WEST ELEV A9.0 PROPOSED SECTIONS A10.0 AREA CHART A11.0 PROP FIRST FLOOR MEP PLAN A12.0 PROP SECOND FLOOR MEP PLAN CAL CALGREEN REQUIREMENTS CG CALGREEN CHECKLIST BMP BEST MGMT PRACTICE 20'- 0" 31'- 4.5" 23'- 7" 5'- 11" 7'- 3" 24'- 7" NA Existing Floor Front PorchGarage Existing First Floor Front PorchGarage New Extn. Eave / O.H. Existing First Floor Front PorchGarage New Extn. FIRE HYDRANT NOTE: THE RESIDENCE EXCEEDS THE 400' MAXIMUM DISTANCE FROM THE HYDRANT TO THE FARTHEST EXTERIOR CORNER OF THE STRUCTURE. FIRE SPRINKLER INSTALLATION THROUGHOUT THE STRUCTURE TO BE PROPOSED IN LIEU OF HYDRANT. NOTE: THE HOMEOWNERS REQUIRE TO CLEAR FLAMMABLE VEGETATION WITHIN 30 FEET OF BUILDINGS AND MODIFY VEGETATION WITHIN 100 FEET AROUND BUILDINGS TO CREATE A DEFENSIBLE SPACE FOR FIREFIGHTERS TO SAFELY PROTECT THEIR HOMES. ONGOING EDUCATION AND INSPECTION ARE CONDUCTED TO ENFORCE THOSE REQUIREMENTS AS PER CALIFORNIA LAW. Future Garage Expansion Future Garage Expansion 1 1 R-2024-007 1/8/2025 Danielle Condit DN LINE OF FIRST FLOOR BELOW (N) LIVING AREA CLG HT : 8'-0" (N) BEDROOM 4 CLG HT : 8'-0" (E) SKY LIGHT 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N SLOPE DN SLOPE DN (N) CRICKET (N) CRICKET 4.5:12 SLOPE DN (N) CLOSET (N) BATH 3 CLG HT : 8'-0" (N) BATH 4 CLG HT : 8'-0" LINE OF FIRST FLOOR BELOW LINE OF ROOF BELOW 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N 4.5:12 SLOPE DN 4.5:12 SLOPE DN 4.5:12 SLOPE DN 16R@7.75" 15T@11" SKY LIGHT ABOVE EM GM REF.CLG HT : 8'-0" (E) OPENING 7068 UP 2R@5" UP (E) DINING CLG HT : 8'-10" (E) LIVING ROOM CLG HT : 8'-0" (E) OPENING (E) BEDROOM 1 CLG HT : 8'-0" (E) BEDROOM 2 CLG HT : 8'-0" BEDROOM 3 CLG HT : 8'-0" (E) CLOSET (E ) C L O S E T (E) ATTIC ACCESS (E) BATH 1 (E) BATH 2 CLG HT : 8'-0" UP 1R@6" WH W D (E) ISLAND SHOWER TUB (E) GARAGE CLG HT : 9'-6" VAULTED CEILING (E ) 1 6 0 7 0 G A R A G E D O O R (E) SKY LIGHT LVL: 1'-5" LVL: 0'-0" LVL: 0'-7" LVL: 0'-0" UP 1R@7" (E) KITCHEN 16R@7.37" 15T@11"UP LVL: 0'-7" UP (N) LANDING LVL: 0'-0" AC (E ) C L O S E T (E) CLOSET LINE OF SECOND FLOOR ABOVE LINE OF SECOND FLOOR ABOVE LINE OF DEMOLITION CHIMNEY LINE OF DEMOLITION WALL (N) SLAB ON GRADE (E) SLAB ON GRADE (E) CRAWLSPACE 1R@5"&1R@6" (N ) A C DW FUTURE GARAGE EXPANSION TO MIN. CLEAR AREA, IN FUTURE, IF REQUIRED FLOOR AREA AND LOT COVERAGE CALCULATIONS DIAGRAM SCALE: 3/16" = 1'-0" A B C F D G E A1 B1 AREA DIMENSIONS SQ.FT. LOT COVERAGE AREA CALCULATIONS A 838.0843'-11" X 19'-1" B 263.6229'-3.5" X 9'-0" C 92.9710'-7.5" X 8'-9" F 33.973'-11.5" X 8'-7" TOTAL LOT COVERAGE AREA 2518.09 TOTAL LOT AREA 6000 LOT COVERAGE RATIO =2518.09 / 6000 = 41.97 % FIRST FLOOR AREA DIMENSIONS SQ.FT. TOTAL FLOOR AREA TOTAL LOT AREA 6000 FAR =2682.74 / 6000 = 44.71 % FLOOR AREA CALCULATIONS A1 9'-7" X 7'-4"70.30 B1 38'-0" X 15'-2"576.35 SECOND FLOOR E 6'-11" X 13'-7"93.95 TOTAL 482 2682.74 FIRST FLOOR SECOND FLOOR H 11'-11" X 19'-2" 201.87 13'-7" EAVE / OVERHANG AREA 2036.09 15 ' - 2 " H G 10'-7.5" X 19'-0" 228.40 43'-11" 19 ' - 1 " 9' - 0 " 29'-312"10'-712"3'-1112" 6' - 1 1 " 19 ' - 0 " 13'-1"10'-712" 18 ' - 9 " 8' - 9 " 8' - 7 " 9'-7"38'-0" 7' - 4 " 19 ' - 2 " 11'-11" D 13'-1" X 18'-9" 245.31 FIRST FLOOR AREA 2036.09 SECOND FLOOR AREA 646.65 FRONT PORCH J 37.92 1' - 8 " 22'-9" X 1'-8" (Future Garage Expansion) J 22'-9" 1 1 1 1 100.00' 100.00' N0 ° 0 0 ' 3 1 " W 60 . 0 0 ' SI D E W A L K 30.00' 7. 4 0 ' 31.26' 31.24' 23.33' 23.37' 5. 7 9 ' 20.00' BSL FF 310.35 GFF 308.82 (w ) (w ) WM "S" SEWER IN WALK CE N T E R L I N E PO P P Y W A Y FLOWER 8" PLUM STREET LIGHT WM BA S I S O F B E A R I N G S N0 ° 0 0 ' 3 1 " W (EOH)(EOH)(EOH) DR I V E W A Y FA C E O F CU R B (E) MULCH (E) MULCH (E) GRAVEL (E) GRAVEL (E) GRAVEL (E) MULCH (N) 24" BOX CERCIS OCCIDENTALIS AND 6 FEET HIGH WHEN PLANTED FRONT YARD TREE: TYPICALLY GROWS 20-40'. (N) 24" BOX LAGERSTROEMIA TUSCARORA PO P P Y W A Y (E) GARAGE SI D E W A L K LA N D S C A P E GM 20'-0" B.S.L MINIMUM FRONT FIRST FLOOR SETBACK FRONT SETBACK MULCH MULCH GARAGE SETBACK 31'-412" 23'-7" UP MAIN HOUSE ENTRY 25'-0" MINIMUM SECOND FLOOR FRONT SETBACK FRONT PORCH MINIMUM FIRST FLOOR SETBACK LINE FRONT YARD IMPERVIOUS PAVING: FRONT YARD AREA = LOT WIDTH X MINIMUM FRONT SETBACK = 60'-0" X 20'-0" = 1200 SQ.FT. MAXIMUM IMPERVIOUS AREA = 50% OF FRONT YARD AREA = 50X1200 /100 = 600 SQ.FT. EXISTING IMPERVIOUS AREA = 473.67 SQ.FT. AREA DIMENSIONS SQ.FT. A 20'-0" X 23-1"461.67 1'-6" X 8'-0" FRONT YARD IMPERVIOUS PAVING B 12.00 LOT COVERAGE RATIO =473.67 / 1200 = 39.47 % TOTAL 473.67 FRONT YARD IMPERVIOUS AREA CALCULATION DIAGRAM 60 ' - 0 " (E) CONCRETE DRIVE WAY 20'-0" A B 1'-6" 8' - 0 " 23 ' - 1 " SCALE: 3/16" = 1'-0" FUTURE GARAGE EXPANSION TO MIN. CLEAR AREA, IN FUTURE, IF REQUIRED 1 11.02.23 Scale Drawing No. AS SHOWN Revision A l l i d e a s , d e s i g n s a n d p l a n s i n d i c a t e d o r r e p r e s e n t e d b y t h i s a r t a r e o w n e d b y a n d r e m a i n t h e p r o p e r t y u s e d o r d i s c l o s e d t o a n y o n e o f O p e n R e m o d e l . N o p a r t s h a l l b e Title Date w i t h o u t p e r m i s s i o n o f t h e C o m p a n y. No. Date RESIDENCE REMODEL Firm Name and Contact : Architecture | Home Designs www.openremodel.com contact@openremodel.com 408.357.3043 Th i s d r a w i n g h a s b e e n p r e p a r e d f o r t h e u s e o f O p e n R e m o d e l ( O R ) C l i e n t . I t m a y n o t b e u s e d , m o d i f i e d , r e p r o d u c e d , o r r e l i e d u p o n b y t h i r d p a r t i e s , e x c e p t a s a g r e e d b y O R o r a s r e q u i r e d b y l a w . O R a c c e p t s n o r e s p o n s i b i l i t y , a n d d e n i e s a n y l i a b i l i t y w h a t s o e v e r , t o a n y p a r t y t h a t u s e s o r r e l i e s o n t h i s d r a w i n g w i t h o u t O R ' s w r i t t e n c o n s e n t . D o n o t s c a l e t h i s d o c u m e n t . O n s i t e m e a s u r e m e n t s t o b e v e r i f i e d b y t h e C o n t r a c t o r . PR O J E C T A D D R E S S : HU E Y R E S I D E N C E R E M O D E L 13 8 1 P O P P Y W A Y , CU P E R T I N O , C A 9 5 0 1 4 Design Manager: Shweta Singh PLAN CHECK REVISION106-14-24 PLAN CHECK REVISION209-20-24 AREA CHART A10.0 R-2024-007 1/8/2025 Danielle Condit GM REF.CLG HT : 8'-0" OPENING 7068 UP 2R@5" 6030 3'-8" AFF SLIDING UP 1R@5"& 1R6" 30 6 8 4030 3'-8" AFF SLIDING 10040 2'-8" AFF XOX SLIDING 6030 3'-8" AFF SLIDING 6030 3'-8" AFF SLIDING DINING CLG HT : 8'-10" LIVING ROOM CLG HT : 8'-0" OPENING FIREPLACE BEDROOM 1 CLG HT : 8'-0" BEDROOM 2 CLG HT : 8'-0" BEDROOM 3 CLG HT : 8'-0" CLOSET CL O S E T CL O S E T CLOSET ATTIC ACCESS BATH 1 BATH 2 CLG HT : 8'-0" 28 6 8 28 6 8 2468 2068 24 6 8 6068 WH W D 2868 60 6 8 60 6 8 UP UP 1R@6"ISLAND SHOWER TUB GARAGE CLG HT : 9'-6" VAULTED CEILING 16 0 7 0 G A R A G E D O O R EM AC SKY LIGHT ABOVE LVL: 1'-5" LVL: 0'-0" LVL: 0'-7" LVL: 0'-7" UP 1R@7" 90 6 8 S L I D I N G D O O R 3020 2'-8" AFF SLIDING 28 6 8 KITCHEN 51'-10" EXISTING FLOOR PLAN SCALE: 1/4"= 1'-0" EXISTING HOUSE AREA = 1440 SQ.FT. EXISTING GARAGE AREA = 430 SQ.FT. EXISTING 3 SIDE COVERED FRONT PORCH = 34 SQ.FT. GM SW-C EM FAUCET A/C EXTERNAL PART WATER METER SEWER CLEANOUT GAS METER ELECTRIC METER ELECTRIC PANELEP AC FT WM 14'-912" 1'-1112" 11'-9" 43'-11" 10 ' - 9 " 2' - 1 " 13 ' - 1 " 13'-312" 18 ' - 4 " 28 ' - 0 12" 18 ' - 9 " 10'-10"4'-412"12'-412"21'-11" 16'-212"35'-712" 18 ' - 4 " 8' - 7 " 17 ' - 9 " 19 ' - 2 " 19 ' - 1 " 46 ' - 1 0 " 7'-11" FRONT PORCH 3 TON AC 17 SEER OUTDOOR UNIT MODEL #: ML17XC1 SOUND (DBA) 73 WITH 5DB BRINMAR SOUND BLANKET DW 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N 4.5:12 SLOPE DN 4.5:12 SLOPE DN 4.5:12 SLOPE DN 4.5:12 SLOPE DN 4.5:12 SLOPE DN RAIN WATER SPOUTS /DRAIN DISCHARGE O/ SPLASHBLOCK RAIN WATER SPOUTS /DRAIN DISCHARGE O/ SPLASHBLOCK RAIN WATER SPOUTS /DRAIN DISCHARGE O/ SPLASHBLOCK RAIN WATER SPOUTS /DRAIN DISCHARGE O/ SPLASHBLOCK 2' - 0 " 2'-0" 2' - 3 " 2'-3" 2' - 3 " 2'-3" 2' - 0 " 2'-0" 2' - 0 " 2'-0" 2' - 0 " 2'-0" SKY LIGHT CHIMNEY EXISTING ROOF PLAN SCALE: 1/4"= 1'-0" EAVE VENTS 11.02.23 Scale Drawing No. AS SHOWN Revision A l l i d e a s , d e s i g n s a n d p l a n s i n d i c a t e d o r r e p r e s e n t e d b y t h i s a r t a r e o w n e d b y a n d r e m a i n t h e p r o p e r t y u s e d o r d i s c l o s e d t o a n y o n e o f O p e n R e m o d e l . N o p a r t s h a l l b e Title Date w i t h o u t p e r m i s s i o n o f t h e C o m p a n y. No. Date RESIDENCE REMODEL Firm Name and Contact : Architecture | Home Designs www.openremodel.com contact@openremodel.com 408.357.3043 Th i s d r a w i n g h a s b e e n p r e p a r e d f o r t h e u s e o f O p e n R e m o d e l ( O R ) C l i e n t . I t m a y n o t b e u s e d , m o d i f i e d , r e p r o d u c e d , o r r e l i e d u p o n b y t h i r d p a r t i e s , e x c e p t a s a g r e e d b y O R o r a s r e q u i r e d b y l a w . O R a c c e p t s n o r e s p o n s i b i l i t y , a n d d e n i e s a n y l i a b i l i t y w h a t s o e v e r , t o a n y p a r t y t h a t u s e s o r r e l i e s o n t h i s d r a w i n g w i t h o u t O R ' s w r i t t e n c o n s e n t . D o n o t s c a l e t h i s d o c u m e n t . O n s i t e m e a s u r e m e n t s t o b e v e r i f i e d b y t h e C o n t r a c t o r . PR O J E C T A D D R E S S : HU E Y R E S I D E N C E R E M O D E L 13 8 1 P O P P Y W A Y , CU P E R T I N O , C A 9 5 0 1 4 Design Manager: Shweta Singh PLAN CHECK REVISION106-14-24 PLAN CHECK REVISION209-20-24 EXIST. FLOOR AND ROOF PLANS A2.0 R-2024-007 1/8/2025 Danielle Condit GROUND LVL. ELEV: 0'-0" FLOOR FINISH ELEV: 1'-5" ROOF RIDGE ELEV: 15'-3" DINING ELEV: 0'-7" CEILING HT. ELEV:9'-5" 6030 SLIDING 9068 SLIDING DOOR ASPHALT SHINGLES TYP. CHIMNEY STUCCO WEST ELEVATION SCALE: 1/4" = 1'-0" 6030 SLIDING 4.5 124.5 12 8' - 0 " 15 ' - 3 " 5' - 1 0 " 1' - 5 " PROPERTY LINE SIDE SETBACKSIDE SETBACK PROPERTY LINE BUILDING ENVELOPE (CMC Section 19.28.070) 5'-11"7'-3" 10 ' - 0 " 10 ' - 0 " 2 5 . 0 ° 25 . 0 ° ROOF RIDGE ELEV: 15'-3" GROUND LVL. ELEV: 0'-0" CEILING HT. ELEV:9'-5" FLOOR FINISH ELEV: 1'-5" 6030 SLIDING GM STUCCO ASPHALT SHINGLES TYP. CHIMNEY NORTH ELEVATION SCALE: 1/4" = 1'-0" 4.5 12 8' - 0 " 15 ' - 3 " 5' - 1 0 " 1' - 5 " ROOF RIDGE ELEV: 15'-3" GROUND LVL. ELEV: 0'-0" CEILING HT. ELEV:9'-5" FLOOR FINISH ELEV: 1'-5" 16070 GARAGE DOOR 10040 XOX SLIDING ASPHALT SHINGLES TYP. STUCCO SIDING CHIMNEY EAST ELEVATION SCALE: 1/4" = 1'-0" 4030 SLIDING 4.5 124.5 12 4.5 124.5 12 8' - 0 " 15 ' - 3 " 5' - 1 0 " 1' - 5 " PROPERTY LINE SIDE SETBACK SIDE SETBACK PROPERTY LINE BUILDING ENVELOPE (CMC Section 19.28.070) 5'-11" 7'-3" 10 ' - 0 " 10 ' - 0 " 2 5 . 0 ° 25 . 0 ° ROOF RIDGE ELEV: 15'-3" GROUND LVL. ELEV: 0'-0" CEILING HT. ELEV:9'-5" FLOOR FINISH ELEV: 1'-5"AC EM 3020 SLIDING 2868 STUCCO CHIMNEY ASPHALT SHINGLES TYP. ASPHALT SHINGLES TYP. SOUTH ELEVATION SCALE: 1/4" = 1'-0" 4.5 12 4.5 12 4.5 12 15 ' - 3 " 8' - 0 " 5' - 1 0 " 1' - 5 " 11.02.23 Scale Drawing No. AS SHOWN Revision A l l i d e a s , d e s i g n s a n d p l a n s i n d i c a t e d o r r e p r e s e n t e d b y t h i s a r t a r e o w n e d b y a n d r e m a i n t h e p r o p e r t y u s e d o r d i s c l o s e d t o a n y o n e o f O p e n R e m o d e l . N o p a r t s h a l l b e Title Date w i t h o u t p e r m i s s i o n o f t h e C o m p a n y. No. Date RESIDENCE REMODEL Firm Name and Contact : Architecture | Home Designs www.openremodel.com contact@openremodel.com 408.357.3043 Th i s d r a w i n g h a s b e e n p r e p a r e d f o r t h e u s e o f O p e n R e m o d e l ( O R ) C l i e n t . I t m a y n o t b e u s e d , m o d i f i e d , r e p r o d u c e d , o r r e l i e d u p o n b y t h i r d p a r t i e s , e x c e p t a s a g r e e d b y O R o r a s r e q u i r e d b y l a w . O R a c c e p t s n o r e s p o n s i b i l i t y , a n d d e n i e s a n y l i a b i l i t y w h a t s o e v e r , t o a n y p a r t y t h a t u s e s o r r e l i e s o n t h i s d r a w i n g w i t h o u t O R ' s w r i t t e n c o n s e n t . D o n o t s c a l e t h i s d o c u m e n t . O n s i t e m e a s u r e m e n t s t o b e v e r i f i e d b y t h e C o n t r a c t o r . PR O J E C T A D D R E S S : HU E Y R E S I D E N C E R E M O D E L 13 8 1 P O P P Y W A Y , CU P E R T I N O , C A 9 5 0 1 4 Design Manager: Shweta Singh PLAN CHECK REVISION106-14-24 PLAN CHECK REVISION209-20-24 EXISTING ELEVATIONS A3.0 R-2024-007 1/8/2025 Danielle Condit 12'-412"21'-11" (E) FRONT PORCH MIN. 1/2" GYPBOARD INSTALLED AT THE GARAGE WALL ADJACENT ROOMS. GYPBOARD TO EXTEND TO THE ROOF SHEATHING 5/8" THICK GYPSUM BOARD FOR GARAGE CEILING. PER SECTION AND TABLE R302.6 OF THE 2019 CRC 1-HR RATED FLOOR CEILING ASSEMBLY AT CEILING HERE PER DETAIL 1/A4.0 1 3 8" SOLID CORE OR 20 MIN. FIRE RATED DOOR W/ SELF CLOSURE AND SELF- LATCHING D2 EM GM REF.CLG HT : 8'-0" (E) OPENING 7068 UP 2R@5" 6030 3'-8" AFF UP 1R@5"&1R@6" (E ) 3 0 6 8 4030 3'-8" AFF (E) SLIDING 10040 2'-8" AFF (E) XOX SLIDING 6030 3'-8" AFF 6030 3'-8" AFF (E) SLIDING (E) DINING CLG HT : 8'-10" (E) LIVING ROOM CLG HT : 8'-0" (E) OPENING (E) BEDROOM 1 CLG HT : 8'-0" (E) BEDROOM 2 CLG HT : 8'-0" BEDROOM 3 CLG HT : 8'-0" (E) CLOSET (E ) C L O S E T (E) ATTIC ACCESS (E) BATH 1 (E) BATH 2 CLG HT : 8'-0" 28 6 8 (E ) 2 8 6 8 (E) 2468 (E) 2068 (E ) 2 4 6 8 (E) 6068 (E ) 6 0 6 8 UP 1R@6" WH W D (E) 2868 (E) ISLANDSHOWER TUB (E) GARAGE CLG HT : 9'-6" VAULTED CEILING (E ) 1 6 0 7 0 G A R A G E D O O R 43'-11" 28 ' - 0 12" 18 ' - 9 " 13'-7"35'-712" 18 ' - 4 " 19 ' - 2 " 27 ' - 8 " 46 ' - 1 0 " 7'-11" (E) SKY LIGHT LVL: 1'-5" LVL: 0'-0" LVL: 0'-7" LVL: 0'-0" UP 1R@7" (E ) 2 8 6 8 (E) KITCHEN UP 3'-3" 3' - 3 " 3' - 3 " 3'-6" LVL: 0'-7" UP 4'-0" MIN. (N) LANDING LVL: 0'-0" AC 13'-2" 2'-712" 51'-10" 51'-10" (E ) C L O S E T (E ) 6 0 6 8 (E) CLOSET (E) SLIDING (E) SLIDING 6' - 1 1 " 6' - 6 " 46 ' - 1 0 " LINE OF SECOND FLOOR ABOVE A A9.0 B A9.0 B A9.0 16R@7.37" 15T@11"A A9.0 LINE OF DEMOLITION CHIMNEY LINE OF DEMOLITION WALL D1 D3 TEMPERED (E) CRAWLSPACE (E) SLAB ON GRADE (N) SLAB ON GRADE (N ) A C 3'' MIN CONCRETE BASE OR HOUSEKEEPING PAD. [CMC 1105.2]AC DISCONNECT W/I SIGHT BUT NOT DIRECTLY BEHIND. (N) CONCEALED DUCTED MINI SPLIT AIR CONDITIONING AND HEAT PUMP DAIKIN FDMQ 12K BTU OUTDOOR UNIT MODEL #: RX12RMVJUA INDOOR UNIT MODEL #: FDMQ12RVJU SOUND (DBA) 51 (E) 3 TON AC RELOCATED 17 SEER OUTDOOR UNIT MODEL #: ML17XC1 SOUND (DBA) 73 WITH 5DB BRINMAR SOUND BLANKET FUTURE GARAGE EXPANSION TO MIN. CLEAR AREA, IN FUTURE, IF REQUIRED LINE OF SECOND FLOOR ABOVE DW 20 ' - 0 " PROPOSED FIRST FLOOR PLAN SCALE: 1/4"= 1'-0" PROPOSED WALLS EXISTING WALLS INFILLED WALLS EXISTING HOUSE AREA = 1440 SQ.FT. EXISTING GARAGE AREA = 430 SQ.FT. EXISTING 3 SIDE COVERED FRONT PORCH = 34 SQ.FT. NEW EXTENDED AREA = 94 SQ.FT. PROPOSED FLOOR AREA = 1440 + 94 = 1534 SQ.FT. FUTURE GARAGE EXPANSION AREA = 38 SQ.FT. DEMOLITION WALLS 1-HR FLOOR-CEILING ASSEMBLY PER DETAIL-1. - HORIZONTAL ASSEMBLIES ARE PERMITTED TO BE PROTECTED WITH A MEMBRANE OR CEILING WHERE THE MEMBRANE OR CEILING PROVIDES THE REQUIRED FIRE- RESISTANCE RATING AND IS INSTALLED IN ACCORDANCE WITH SECTION 711. 1-HR RATED FLOOR CEILING ASSEMBLY BETWEEN GARAGE AND 2ND FLOOR N.T.S.1 System Performance 1 HR Fire RAL-TL-04-034 & UL File No. L569 RAL-IN-04-007 58 STC, 55 IIC System Description Dimensional Lumber - engineered wood laminate - SRM-25 sound mat - 1" LEVELROCK Floor Underlayment - T&G or plywood flooring - 2x10 wood joist 16" o.c. or 24" o.c. when battens used - 3-1/4" fiberglass batt insulation - 5/8" SHEETROCK Brand FIRECODE C Core Gypsum Panels 12-5/8" FIRE RESISTANCE FLOOR TO CEILING NOTES: - FIRE RESISTANCE RATINGS OF STRUCTURAL MEMBERS AND ASSEMBLIES SHALL COMPLY WITH SECTION 704 (CBC). THE FIRE RESISTANCE RATINGS SHALL NOT BE LESS THAN THE RATINGS REQUIRED FOR THE FIRE-RESISTANCE RATED ASSEMBLIES SUPPORTED BY THE STRUCTURAL MEMBERS. - MEMBERS OF THE PRIMARY STRUCTURAL FRAME OTHER THAN COLUMNS THAT ARE REQUIRED TO HAVE PROTECTION TO ACHIEVE A FIRE-RESISTANCE RATING AND SUPPORT MORE THAN TWO FLOORS OR ONE FLOOR AND ROOF, OR SUPPORT A LOAD- BEARING WALL OR A NON LOAD-BEARING WALL MORE THAN TWO THEM ON STORIES HIGH, SHALL BE PROVIDED INDIVIDUAL ENCASEMENT PROTECTION BY PROTECTING ALL SIDES FOR THE FULL LENGTH, INCLUDING CONNECTIONS TO OTHER STRUCTURAL MEMBERS, WITH MATERIALS HAVING THE REQUIRED FIRE-RESISTANCE RATING. - STUDS, COLUMNS AND BOUNDARY ELEMENTS THAT ARE INTEGRAL ELEMENTS IN WALLS OF LIGHT-FRAME CONSTRUCTION AND ARE LOCATED ENTIRELY BETWEEN THE TOP AND BOTTOM PLATES OR TRACKS SHALL BE PERMITTED TO HAVE REQUIRED FIRE-RESISTANCE RATINGS PROVIDED BY THE MEMBRANE PROTECTION PROVIDED FOR THE WALL. - THE EDGES OF LUGS, BRACKETS, RIVETS AND BOLT HEADS ATTACHED TO STRUCTURAL MEMBERS SHALL BE PERMITTED TO EXTEND TO WITHIN 1 INCH (25 MM) OF THE SURFACE OF THE FIRE PROTECTION. - THE VOID CREATED AT THE INTERSECTION OF A FLOOR/CEILING ASSEMBLY AND AN EXTERIOR CURTAIN WALL ASSEMBLY SHALL BE PROTECTED IN ACCORDANCE WITH SECTION 715.4. - FIRE BARRIERS SHALL EXTEND FROM THE TOP OF THE FOUNDATION OR FLOOR/CEILING ASSEMBLY BELOW TO THE UNDERSIDE OF THE FLOOR OR ROOF SHEATHING, SLAB OR DECK ABOVE AND SHALL BE SECURELY ATTACHED THERETO. SUCH FIRE BARRIERS SHALL BE CONTINUOUS THROUGH CONCEALED SPACE, SUCH AS THE SPACE ABOVE A SUSPENDED CEILING. JOINTS AND VOIDS AT INTERSECTIONS SHALL COMPLY WITH SECTIONS 707.8 AND 707.9 BATHROOM SPECIFIC NOTES: A. REQUIRED CLEARANCES ARE 24” IN FRONT AND 15” FROM CENTERLINE TO WALL OR CABINET. (30” TOTAL) (CPC SEC. 402.5) B. WHERE THE WATER CLOSET (OR OTHER PLUMBING FIXTURE) COMES INTO CONTACT WITH THE WALL OR FLOOR, THE JOINT SHALL BE CAULKED AND SEALED TO BE WATERTIGHT. (CPC 402.2) C. NEW OR ALTERED SHOWER COMPARTMENTS SHALL HAVE A MINIMUM FINISHEDDAM, CURB, OR THRESHOLD NOT LESS THAN 2 INCHES OR EXCEEDING 9 INCHES IN DEPTH, WITH AN INTERIOR OF 1,024 SQUARE INCHES AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE MEASURED TO THE CENTER OF THE THRESHOLD. (CPC SEC.408.5 & CPC SEC. 408.6). 1. SHOWER ENTRANCE SHALL BE PROVIDED WITH A MINIMUM OF 22” CLEAR OPENING AND,IF FEATURED WITH A DOOR SHALL BE SLIDING OR OUTWARD SWING. 2. ANY GLAZING WITHIN 60” RADIUS OF TUB/SHOWER ENCLOSURES SHALL BE TEMPERED SAFETY GLASS (BATHROOMS INCLUSIVE OF SHOWERS SHALL HAVE ALL GLAZING TEMPERED SAFETY GLASS) 3. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH A PRESSURE / BALANCE THERMOSTATIC MIXING VALVE. MAX FLOW OF ANY SHOWER HEADS OR HANDHELD OUTLETS CONTROLLED BY DIVERTER VALVE SHALL BE 1.8 G.P.M.COMBINED. 4. SHOWER COMPARTMENTS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, NONABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 72 INCHES (6 FT). (CRC R307.2) 5. SHOWER COMPARTMENT SHALL BE A MINIMUM 1,024 SQUARE INCHES ENCOMPASSING A 30" DIA. CIRCLE. (CPC 408.5 & 408.6) WATER EFFICIENT PLUMBING FIXTURES (CALIFORNIA CIVIL CODE 1101.4(A)) : RESIDENTIAL PROPERTY BUILT AND AVAILABLE FOR USE OR OCCUPANCY ON OR BEFORE JANUARY 1, 1994, BE EQUIPPED WITH WATER-CONSERVING PLUMBING FIXTURES.ON OR BEFORE JANUARY 1, 2017, NONCOMPLIANT PLUMBING FIXTURES IN ANY SINGLE-FAMILY RESIDENTIAL REAL PROPERTY SHALL BE REPLACED BY THE PROPERTY OWNER WITH WATER-CONSERVING PLUMBING FIXTURES. Type of Fixture Required Water-Conserving Plumbing Fixture (maximum flow rates) Water Closet (Toilet) 1.28 gpf Showerhead 1.80 gpm Lavatory Faucets 1.20 gpm Kitchen Faucets 1.80 gpm BATHROOM SPECIFIC NOTES: ·ALL SHOWER ENCLOSURE AND DOORS TO BE FRAMELESS TEMPERED GLASS W/PIVOT DOOR MIN. 22" UNOBSTRUCTED DOOR OPENING. ·SHOWER COMPARTMENTS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, NONABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 72 INCHES (6 FT). (CRC R307.2) ·SHOWER COMPARTMENT SHALL BE A MINIMUM 1,024 SQUARE INCHES ENCOMPASSING A 30" DIA. CIRCLE. (CPC 408.5 & 408.6) EGRESS WINDOW REQUIREMENTS: ·THE BOTTOM OF THE EGRESS WINDOW OPENING CAN’T EXCEED 44” FROM THE FINISHED FLOOR. ·THE MINIMUM OPENING AREA OF THE EGRESS WINDOW IS 5.7 SQUARE FEET. ·THE MINIMUM EGRESS WINDOW OPENING HEIGHT IS 24” HIGH. ·THE MINIMUM EGRESS WINDOW OPENING IS 20” WIDE. GM SW-C EM FAUCET A/C EXTERNAL PART WATER METER SEWER CLEANOUT GAS METER ELECTRIC METER ELECTRIC PANELEP AC FT WM LEGEND: NOTE: ALL EXISTING WINDOW MATERIAL IS VINYL AND DOOR MATERIAL IS ALUMINUM UNLESS OTHERWISE SPECIFIED. 1 1 1 1 ARCHITECTURAL STYLE: RANCH STYLE 2 11.02.23 Scale Drawing No. AS SHOWN Revision A l l i d e a s , d e s i g n s a n d p l a n s i n d i c a t e d o r r e p r e s e n t e d b y t h i s a r t a r e o w n e d b y a n d r e m a i n t h e p r o p e r t y u s e d o r d i s c l o s e d t o a n y o n e o f O p e n R e m o d e l . N o p a r t s h a l l b e Title Date w i t h o u t p e r m i s s i o n o f t h e C o m p a n y. No. Date RESIDENCE REMODEL Firm Name and Contact : Architecture | Home Designs www.openremodel.com contact@openremodel.com 408.357.3043 Th i s d r a w i n g h a s b e e n p r e p a r e d f o r t h e u s e o f O p e n R e m o d e l ( O R ) C l i e n t . I t m a y n o t b e u s e d , m o d i f i e d , r e p r o d u c e d , o r r e l i e d u p o n b y t h i r d p a r t i e s , e x c e p t a s a g r e e d b y O R o r a s r e q u i r e d b y l a w . O R a c c e p t s n o r e s p o n s i b i l i t y , a n d d e n i e s a n y l i a b i l i t y w h a t s o e v e r , t o a n y p a r t y t h a t u s e s o r r e l i e s o n t h i s d r a w i n g w i t h o u t O R ' s w r i t t e n c o n s e n t . D o n o t s c a l e t h i s d o c u m e n t . O n s i t e m e a s u r e m e n t s t o b e v e r i f i e d b y t h e C o n t r a c t o r . PR O J E C T A D D R E S S : HU E Y R E S I D E N C E R E M O D E L 13 8 1 P O P P Y W A Y , CU P E R T I N O , C A 9 5 0 1 4 Design Manager: Shweta Singh PLAN CHECK REVISION106-14-24 PLAN CHECK REVISION209-20-24 A4.0 PROPOSED FIRST FLOOR PLAN R-2024-007 1/8/2025 Danielle Condit 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N 4.5:12 SLOPE DN 4.5:12 SLOPE DN 4.5:12 SLOPE DN (E) SKY LIGHT 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N SLOPE DN SLOPE DN (N) CRICKET (N) CRICKET 4.5:12 SLOPE DN 2% SLOPE DN TEMPERED FROSTED 4'-0" 16R@7.75" 15T@11" TEMPERED EGRESS CABLE RAILING PER DETAIL A5.016R@7.75" 15T@11" MIN. 24" IN FRONT OF THE WC MINIMUM 15" ON BOTH THE SIDES REQUIRED FROM CENTER SHOWER SPRAY MIN. 30" DIA. CLEARANCE Ø 2 ' - 6 " Ø2 ' - 6 " SKY LIGHT ABOVE SHOWER CONTROL VALVES SHOWER CONTROL VALVES W2 D3 DN LINE OF FIRST FLOOR BELOW (N) LIVING AREA CLG HT : 8'-0" (N) BEDROOM 4 CLG HT : 8'-0" (N) CLOSET (N) BATH 3 CLG HT : 8'-0" (N) BATH 4 CLG HT : 8'-0" LINE OF FIRST FLOOR BELOW 3'-1" LINE OF ROOF BELOW A A9.0 B A9.0 B A9.0 A A9.0 W3 W4 W5 W6 W7 W8W9 D4 D4 D5 D5 27 ' - 8 " 2' - 9 " 3' - 0 " 3'-0"1'-3"3'-0" 3'-0"1'-3"1'-3"3'-0" 1'-3" 6' - 1 1 " 7' - 5 " 7' - 4 " 7' - 1 0 " 16'-9" 11 ' - 1 1 " 15 ' - 2 " 47'-7" 3'-3" 3' - 3 " 3' - 3 " 11'-0" 1'-712"47'-7"2'-712" 27 ' - 8 " 4' - 0 " 46 ' - 1 0 " 8'-6"9'-2" 2' - 0 " 15 ' - 2 " 1'-712" 51'-10" 9'-7" 2'-712" 51'-10" 4' - 0 " 46 ' - 1 0 " 30'-10" 3' - 3 " 5' - 0 " 5' - 3 " 4'-6" 15'-6" 38'-0" LINE OF FIRST FLOOR BELOW LINE OF ROOF BELOW LINE OF ROOF ABOVE TEMPERED TEMPERED TEMPERED TEMPERED TEMPERED TEMPERED W5 TEMPERED FROSTED PROPOSED SECOND FLOOR PLAN SCALE: 1/4"= 1'-0" PROPOSED WALLS PROPOSED SECOND FLOOR AREA = 647 SQ.FT. STAIR AND HANDRAIL NOTES: ·STAIRWAY TO BE A MINIMUM 36" CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL HEIGHT, WITH HANDRAILS PROJECTING A MAXIMUM OF 4.5" ON EITHER SIDE OF THE STAIRWAY (NOT LESS THAN 31.5" MINIMUM WIDTH WHERE HANDRAIL INSTALLED ON ONE SIDE, AND 27" MINIMUM WIDTH WHERE HANDRAILS ARE INSTALLED ON BOTH SIDES OF THE STAIRWAY). CRC R311.7.1 AND CBC 1011.2 EXCEPTION 1. ·STAIRS TO BE MAXIMUM 7.75" RISE AND MINIMUM 10" RUN. CRC R311.7.4.1 AND R311.7.4.2 AND CBC 1011.5.2 EXCEPTION 3 ·HANDRAILS SHALL HAVE A SPACE BETWEEN THE WALL AND THE HANDRAIL OF NOT LESS THAN 1-1/2" CBC 1014.7, AND WITH ONE OF THE FOLLOWING TYPES (OR EQUIVALENT GRASPABILITY): 1. HANDRAILS TO HAVE A CIRCULAR CROSS-SECTION OF AT LEAST 1-1/4" TO 2", OR IF THE HANDRAIL IS NOT CIRCULAR IT SHALL HAVE A PERIMETER DIMENSION OF AT LEAST 4" TO 6-1/2" WITH A MAXIMUM CROSS-SECTION DIMENSION OF 2-1/4". CRC R311.7.7.3 - TYPE 1 OR CBC 1014.3.1 2. HANDRAILS TO HAVE A PERIMETER GREATER THAN 6-1/4" SHALL HAVE A GRASPABLE FINGER RECESS AREA ON BOTH SIDES OF THE PROFILE. THE FINGER SHALL BEGIN WITHIN A DISTANCE OF 3/4" MEASURED VERTICALLY FROM THE TALLEST PORTION OF THE PROFILE AND ACHIEVE A DEPTH OF AT LEAST 5/16" WITHIN 7/8" BELOW THE WIDEST PORTION OF THE PROFILE. THIS REQUIRED DEPTH SHALL CONTINUE FOR AT LEAST 1-3/4" BELOW THE TALLEST PORTION OF THE PROFILE, WITH THE MINIMUM WIDTH OF THE HANDRAIL ABOVE THE RECESS SHALL BE 1-1/4" TO A MAXIMUM OF 2-3/4". CRC R311.7.7.3 - TYPE 2 OR CBC 1014.3.2 ·THE GUARD AT THE OPEN SIDE OF THE STAIRWAY SHALL BE A MINIMUM OF 34" ABOVE THE LEADING EDGES OF THE TREADS. WHERE THE GUARD ALSO SERVES AS THE HANDRAIL ON THE OPEN SIDE OF THE STAIRWAY THE GUARD SHALL BE 34" TO 38" ABOVE THE LEADING EDGE OF THE TREADS. CRC R312.1.2 EXCEPTIONS OR CBC 1014.2 ·GUARDS ON THE OPEN SIDE OF THE STAIRWAY SHALL NOT HAVE OPENINGS WHICH ALLOW THE PASSAGE OF A SPHERE 4-3/8" IN DIAMETER BETWEEN THE INTERMEDIATE RAILS, AND THAT THE TRIANGULAR OPENINGS FORMED BY THE RISER, TREAD AND BOTTOM RAIL OF THE GUARD SHALL NOT ALLOW PASSAGE OF A SPHERE 6" IN DIAMETER. CRC R312.1.3 EXCEPTIONS OR CBC 1015.4 EXCEPTIONS 1 AND 2 ·FOR SINGLE FAMILY DWELLINGS, HANDRAILS AND GUARDS SHALL BE DESIGNED TO RESIST A CONCENTRATED LOAD OF 200 POUNDS APPLIED IN ANY DIRECTION AT ANY POINT ON THE HANDRAIL OR TOP RAIL TO PRODUCE THE MAXIMUM LOAD EFFECT ON THE ELEMENT BEING CONSIDERED AND TO TRANSFER THIS LOAD THROUGH THE SUPPORTS TO THE STRUCTURE. CBC 1607.8.1 EXCEPTION 1, ASCE 7 SECTION 4.5.1, CRC TABLE 301.5 24" 28"34" 38" 48" POST TO POST 3.5" TYP. SPACING BOTTOM RAIL OPTIONAL 3" HANDRAIL WITH CIRCULAR 1-1/4 IN. MIN / 2 IN. MAX DIAMETER HANDRAIL THAT IS NOT CIRCULAR MUST HAVE A PERIMETER OF 4 IN. MIN/6-1/4 IN. MAX WITH A MAXIMUM CROSS SECTION DIMENSION OF 2-1/4 INCHES 1-1/2 IN. 1-1/2 IN. 0.01 IN. RADIUS NONCIRCULAR HANDRAIL CIRCULAR HANDRAIL CABLE RAILING SCALE: N.T.S1 - WHERE THE OPENING OF AN OPERABLE WINDOW IS LOCATED MORE THAN 72 INCHES ABOVE THE FINISHED GRADE OR SURFACE BELOW THE LOWEST PART OF THE CLEAR OPENING OF THE WINDOW SHALL BE A MINIMUM OF 24 INCHES ABOVE THE FINISHED FLOOR OF THE ROOM IN WHICH THE WINDOW IS LOCATED. - OPERABLE SECTIONS OF WINDOWS SHALL NOT PERMIT OPENINGS THAT ALLOW PASSAGE OF A 4 INCH DIAMETER SPHERE WHERE SUCH OPENINGS ARE LOCATED WITHIN 24 INCHES OF THE FINISHED FLOOR. - WINDOW FALL PREVENTION DEVICES AND WINDOW GUARDS, WHERE PROVIDED, SHALL COMPLY WITH THE REQUIREMENTS OF ASTM F 2090. NOTE: APPLY WINDOW FALL PREVENTION DEVICE FOR ALL OPERABLE KID'S ROOM WINDOWS: NOTE (SECTION 18.09.040 2B): SECOND STORY WINDOWS, EXCLUDING THOSE REQUIRED FOR EGRESS, SHALL HAVE A FIVE-FOOT SILL HEIGHT AS MEASURED FROM THE SECOND-FLOOR LEVEL, OR UTILIZE OBSCURED GLAZING ON THE ENTIRETY OF THE WINDOW WHEN FACING ADJACENT PROPERTIES. SECOND STORY EGRESS WINDOWS SHALL UTILIZE OBSCURED GLAZING ON THE ENTIRETY OF THE WINDOWS WHICH FACE ADJACENT PROPERTIES. WATER EFFICIENT PLUMBING FIXTURES (CALIFORNIA CIVIL CODE 1101.4(A)) : RESIDENTIAL PROPERTY BUILT AND AVAILABLE FOR USE OR OCCUPANCY ON OR BEFORE JANUARY 1, 1994, BE EQUIPPED WITH WATER-CONSERVING PLUMBING FIXTURES.ON OR BEFORE JANUARY 1, 2017, NONCOMPLIANT PLUMBING FIXTURES IN ANY SINGLE-FAMILY RESIDENTIAL REAL PROPERTY SHALL BE REPLACED BY THE PROPERTY OWNER WITH WATER-CONSERVING PLUMBING FIXTURES. Type of Fixture Required Water-Conserving Plumbing Fixture (maximum flow rates) Water Closet (Toilet) 1.28 gpf Showerhead 1.80 gpm Lavatory Faucets 1.20 gpm Kitchen Faucets 1.80 gpm BATHROOM SPECIFIC NOTES: A. REQUIRED CLEARANCES ARE 24” IN FRONT AND 15” FROM CENTERLINE TO WALL OR CABINET. (30” TOTAL) (CPC SEC. 402.5) B. WHERE THE WATER CLOSET (OR OTHER PLUMBING FIXTURE) COMES INTO CONTACT WITH THE WALL OR FLOOR, THE JOINT SHALL BE CAULKED AND SEALED TO BE WATERTIGHT. (CPC 402.2) C. NEW OR ALTERED SHOWER COMPARTMENTS SHALL HAVE A MINIMUM FINISHEDDAM, CURB, OR THRESHOLD NOT LESS THAN 2 INCHES OR EXCEEDING 9 INCHES IN DEPTH, WITH AN INTERIOR OF 1,024 SQUARE INCHES AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE MEASURED TO THE CENTER OF THE THRESHOLD. (CPC SEC.408.5 & CPC SEC. 408.6). 1. SHOWER ENTRANCE SHALL BE PROVIDED WITH A MINIMUM OF 22” CLEAR OPENING AND,IF FEATURED WITH A DOOR SHALL BE SLIDING OR OUTWARD SWING. 2. ANY GLAZING WITHIN 60” RADIUS OF TUB/SHOWER ENCLOSURES SHALL BE TEMPERED SAFETY GLASS (BATHROOMS INCLUSIVE OF SHOWERS SHALL HAVE ALL GLAZING TEMPERED SAFETY GLASS) 3. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH A PRESSURE / BALANCE THERMOSTATIC MIXING VALVE. MAX FLOW OF ANY SHOWER HEADS OR HANDHELD OUTLETS CONTROLLED BY DIVERTER VALVE SHALL BE 2.00 G.P.M.COMBINED. 4. SHOWER COMPARTMENTS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, NONABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 72 INCHES (6 FT). (CRC R307.2) 5. SHOWER COMPARTMENT SHALL BE A MINIMUM 1,024 SQUARE INCHES ENCOMPASSING A 30" DIA. CIRCLE. (CPC 408.5 & 408.6) 3 0 . 0 ° 30 . 0 ° 30 . 0 ° 3 0 . 0 ° 3 0 . 0 ° 30.0°30.0° LINE OF PRIVACY VIEWSHEDS LINE OF PRIVACY VIEWSHEDS ARCHITECTURAL STYLE: RANCH STYLE 2 2 11.02.23 Scale Drawing No. AS SHOWN Revision A l l i d e a s , d e s i g n s a n d p l a n s i n d i c a t e d o r r e p r e s e n t e d b y t h i s a r t a r e o w n e d b y a n d r e m a i n t h e p r o p e r t y u s e d o r d i s c l o s e d t o a n y o n e o f O p e n R e m o d e l . N o p a r t s h a l l b e Title Date w i t h o u t p e r m i s s i o n o f t h e C o m p a n y. No. Date RESIDENCE REMODEL Firm Name and Contact : Architecture | Home Designs www.openremodel.com contact@openremodel.com 408.357.3043 Th i s d r a w i n g h a s b e e n p r e p a r e d f o r t h e u s e o f O p e n R e m o d e l ( O R ) C l i e n t . I t m a y n o t b e u s e d , m o d i f i e d , r e p r o d u c e d , o r r e l i e d u p o n b y t h i r d p a r t i e s , e x c e p t a s a g r e e d b y O R o r a s r e q u i r e d b y l a w . O R a c c e p t s n o r e s p o n s i b i l i t y , a n d d e n i e s a n y l i a b i l i t y w h a t s o e v e r , t o a n y p a r t y t h a t u s e s o r r e l i e s o n t h i s d r a w i n g w i t h o u t O R ' s w r i t t e n c o n s e n t . D o n o t s c a l e t h i s d o c u m e n t . O n s i t e m e a s u r e m e n t s t o b e v e r i f i e d b y t h e C o n t r a c t o r . PR O J E C T A D D R E S S : HU E Y R E S I D E N C E R E M O D E L 13 8 1 P O P P Y W A Y , CU P E R T I N O , C A 9 5 0 1 4 Design Manager: Shweta Singh PLAN CHECK REVISION106-14-24 PLAN CHECK REVISION209-20-24 PROPOSED SECOND FLOOR PLAN A5.0 R-2024-007 1/8/2025 Danielle Condit W10 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N 4.5:12 SLOPE DN 4.5:12 SLOPE DN 4.5:12 SLOPE DN 4.5:12 SLOPE DN (E) SKY LIGHT 4. 5 : 1 2 SL O P E D N SLOPE DN SLOPE DN (N) CRICKET (N) CRICKET (E) RAIN WATER SPOUTS /DRAIN DISCHARGE O/ SPLASHBLOCK 2' - 0 " 2'-0" 2' - 3 " 2'-3" 2' - 3 " 2'-3" 2' - 0 " 2' - 0 " 2'-0" 2' - 0 " 2'-0" LINE OF ROOF BELOW LINE OF SECOND FLOOR BELOW LINE OF FIRST FLOOR BELOW LINE OF FIRST FLOOR BELOW LINE OF SECOND FLOOR BELOW 2'-0" 2' - 0 " 2' - 0 " 2'-0"2'-0" 2' - 0 " 2'-0" 2' - 0 " 2'-0" 2' - 0 " 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N 4.5:12 SLOPE DN (E) RAIN WATER SPOUTS /DRAIN DISCHARGE O/ SPLASHBLOCK (E) RAIN WATER SPOUTS /DRAIN DISCHARGE O/ SPLASHBLOCK (N) RAIN WATER SPOUTS /DRAIN DISCHARGE O/ SPLASHBLOCK (N) RAIN WATER SPOUTS /DRAIN DISCHARGE O/ SPLASHBLOCK A A9.0 A A9.0 B A9.0 B A9.0 4'-0" 2% SLOPE DN 2' - 0 " (N) FLAT ROOF PROPOSED ROOF PLAN SCALE: 1/4"= 1'-0"EXISTING ROOF PROPOSED SECOND FLOOR ROOF PROPOSED FIRST FLOOR ROOF LEGEND: (N) BOX VENT (N) EAVE VENT NEW BOX VENT (19"X4") (N) BOX VENT (N) EAVE VENT EXISTING EAVE VENTS TO PREVENT EMBER INTRUSION IF NOT ALREADY NEW EAVE VENTS TO PREVENT EMBER INTRUSION (N) 2- EAVE VENT (REPLACED GARAGE EXISTING-2 ) FIRE RATED ROOF NOTE: ROOF TO BE CONSTRUCTED OF CLASS A FIRE RESISTANT STANDARDS IN STATE RESPONSIBILITY AREAS AND IN VERY HIGH FIRE HAZARD SEVERITY ZONES IN LOCAL RESPONSIBILITY AREAS. 2 FLOOR FINISH LEVEL W1 NOT IN USED W2 NO:1 (N) STAIRCASE W3 NO:1 (N) STAIRCASE VINYL TEMPERED GLASS FIXED WINDOW 6'-0" 3' - 0 " 3' - 8 " 6' - 8 " T W4 NO:1 (N) LIVING AREA VINYL FIXED TEMPERED FROSTED GLASS WINDOW F VINYL TEMPERED GLASS FIXED WINDOW 1 F T 5' - 0 " 1' - 8 " 6' - 8 " 4'-0"4'-0" 3' - 0 " 3' - 8 " 6' - 8 " TO F 2 4'-0"4'-0" 8'-0" 1' - 6 " 5' - 2 " 6' - 8 " W5 NO:2 (N) LIVING AREA VINYL OPERABLE TEMPERED GLASS SLIDING WINDOW W6 NO:1 (N) BATH 4 VINYL OPERABLE TEMPERED FROSTED GLASS SLIDING WINDOW 1'-3"1'-3" 2'-6" 1' - 6 " 5' - 2 " 6' - 8 " TO W7 NO:1 (N) BEDROOM 4 VINYL OPERABLE TEMPERED GLASS SLIDING WINDOW 4'-0"4'-0" 8'-0" 3' - 2 " 3' - 6 " 6' - 8 " VINYL OPERABLE TEMPERED T T FLOOR FINISH LEVEL FLOOR FINISH LEVEL 1'-9"1'-9" 3'-6" 1' - 6 " 5' - 2 " 6' - 8 " W9 NO:1 (N) LIVING AREA 2'-3" 1' - 9 " NO:1 (N) BATH 3 SKY LIGHT (C01) W10 T VINYL OPERABLE TEMPERED GLASS SLIDING WINDOW FLOOR FINISH LEVEL EXTERIOR DOOR D1 NO: 1 (N) STAIRCASE INTERIOR DOOR D3 NO: 2 (N) STAIRCASE & (N) BEDROOM 4 INTERIOR DOOR D4 NO: 2 (N) BATH 3 & BATH 4 INTERIOR CLOSET SLIDING DOOR NO:2 BEDROOM 4 D5 4'-0"4'-0" 6' - 8 " EXTERIOR TEMPERED GLASS SLIDING DOOR NO:1 (E) DINING D2 DOOR WINDOW SCHEDULE SCALE: 1/4" = 1'-0" TEMPERED GLASST FROSTED OBSCURED GLASSO LEGEND: TEMPERED FROSTED OBSCURED GLASSTO 3'-0" 6' - 8 " 2'-8" 6' - 8 " 2'-6" 6' - 8 " 5'-0" 6' - 8 " 2'-6"2'-6" FIXED GLASSF T NOTE: - NEW WINDOWS AND DOORS TO BE CONSTRUCTED OF MULTIPANE GLAZING WITH MINIMUM ONE TEMPERED PANE MEETING THE REQUIREMENTS OF SECTION 2406 SAFETY GLAZING. - GLAZING IN EXTERIOR DOORS SHALL COMPLY WITH SECTION 708A.2.1. - ALL EXTERIOR DOORS TO BE CONSTRUCTED OF IGNITION-RESISTANT MATERIALS. T 8'-0" 2 11.02.23 Scale Drawing No. AS SHOWN Revision A l l i d e a s , d e s i g n s a n d p l a n s i n d i c a t e d o r r e p r e s e n t e d b y t h i s a r t a r e o w n e d b y a n d r e m a i n t h e p r o p e r t y u s e d o r d i s c l o s e d t o a n y o n e o f O p e n R e m o d e l . N o p a r t s h a l l b e Title Date w i t h o u t p e r m i s s i o n o f t h e C o m p a n y. No. Date RESIDENCE REMODEL Firm Name and Contact : Architecture | Home Designs www.openremodel.com contact@openremodel.com 408.357.3043 Th i s d r a w i n g h a s b e e n p r e p a r e d f o r t h e u s e o f O p e n R e m o d e l ( O R ) C l i e n t . I t m a y n o t b e u s e d , m o d i f i e d , r e p r o d u c e d , o r r e l i e d u p o n b y t h i r d p a r t i e s , e x c e p t a s a g r e e d b y O R o r a s r e q u i r e d b y l a w . O R a c c e p t s n o r e s p o n s i b i l i t y , a n d d e n i e s a n y l i a b i l i t y w h a t s o e v e r , t o a n y p a r t y t h a t u s e s o r r e l i e s o n t h i s d r a w i n g w i t h o u t O R ' s w r i t t e n c o n s e n t . D o n o t s c a l e t h i s d o c u m e n t . O n s i t e m e a s u r e m e n t s t o b e v e r i f i e d b y t h e C o n t r a c t o r . PR O J E C T A D D R E S S : HU E Y R E S I D E N C E R E M O D E L 13 8 1 P O P P Y W A Y , CU P E R T I N O , C A 9 5 0 1 4 Design Manager: Shweta Singh PLAN CHECK REVISION106-14-24 PLAN CHECK REVISION209-20-24 PROPOSED ROOF PLAN A6.0 R-2024-007 1/8/2025 Danielle Condit CEILING HT. ELEV:9'-5" FLOOR FINISH ELEV: 1'-5" EAST ELEVATION SCALE: 1/4" = 1'-0" (N) SECOND FLOOR ELEV:10'-5" (N) SECOND FLOOR CEILING ELEV:18'-5" (N) ROOF RIDGE ELEV: 21'-10" 3' - 5 " 8' - 0 " 21 ' - 1 0 " T O T A L B U I L D I N G H E I G H T F R O M N A T U R A L G R A D E 8' - 0 " 1' - 5 " 1' - 0 " NATURAL GRADE LVL. ELEV: 0'-0" 18 ' - 5 " 2 N D F L O O R W A L L H E I G H T A T T O P O F W A L L P L A T E TEMPERED GLASST FROSTED OBSCURED GLASSO LEGEND: TEMPERED FROSTED OBSCURED GLASSTO (N) WOODEN BELLY BAND IN GRAY COLOR MATCHING THE SIDING (E) 16070 GARAGE DOOR (E) 10040 XOX SLIDING (E) STUCCO KEEP AS IS (E) SIDING PAINT TO LIGHT GRAY COLOR (E) 4030 SLIDING 4.5 12 4.5 12 4.5 12 4.5 12 4.5 12 4.5 12 W7 (E) ASPHALT SHINGLES TYP.(N) LIGHT FRENCH GRAY SIDING (E) WOODEN BELLY BAND AND PAINT WITH GRAY COLOR T 1381 1381 FIRE RATED ROOF NOTE: ROOF TO BE CONSTRUCTED OF CLASS A FIRE RESISTANT STANDARDS IN STATE RESPONSIBILITY AREAS AND IN VERY HIGH FIRE HAZARD SEVERITY ZONES IN LOCAL RESPONSIBILITY AREAS. NOTE: INSTALL RADIANT BARRIER ROOF SHEATHING, PER ENERGY CODE COMPLIANCE. PROPERTY LINE SIDE SETBACK SIDE SETBACK PROPERTY LINE BUILDING ENVELOPE (CMC Section 19.28.070) 5'-11" 7'-3" 10 ' - 0 " 10 ' - 0 " 2 5 . 0 ° 25 . 0 ° 3' - 6 " 9' - 5 " 1 S T F L O O R W A L L HE I G H T A T T O P O F W A L L P L A T E 1 1 1 2 2 CEILING HT. ELEV:9'-5" FLOOR FINISH ELEV: 1'-5" (E) 6030 SLIDING GM NORTH ELEVATION SCALE: 1/4" = 1'-0" 4.5 12 W8 W9(N) SIDING (E) ASPHALT SHINGLES TYP. (N) ASPHALT SHINGLES TYP. W11 8' - 0 " 1' - 5 " NATURAL GRADE LVL. ELEV: 0'-0" 9' - 5 " 1 S T F L O O R W A L L HE I G H T A T T O P O F W A L L P L A T E T T 5' - 2 " 5' - 2 " T 5' - 2 " (N) SECOND FLOOR ELEV:10'-5" (N) SECOND FLOOR CEILING ELEV:18'-5" (N) ROOF RIDGE ELEV: 21'-10" 3' - 5 " 21 ' - 1 0 " T O T A L B U I L D I N G H E I G H T F R O M N A T U R A L G R A D E 8' - 0 " 1' - 0 " 18 ' - 5 " 2 N D F L O O R W A L L H E I G H T A T T O P O F W A L L P L A T E 1 (E) FASCIA PAINT WITH BLACK PAINT (N) GRAY SIDING (N) BLACK FASCIA (E) STUCCO KEEP AS IS 1 1 W5 WHITE STUCCO PAINT: EXTERNAL WALL PAINT ALABASTER SW 7008 (V.I.F) EXISTING STUCCO KEEP AS IS. BLACK GUTTER: BLACK WINDOW TRIM AND FASCIA TRICORN BLACK SW 6258 GRAY SIDING: EXTERNAL GRAY PAINT LIGHT FRENCH GRAY SW 0055 EXISTING SIDING TO BE PAINTED WITH LIGHT GRAY PAINT. ASPHALT SHINGLES: MATCH WITH THE EXISTING HOUSE MATERIAL BOARD 1 ARCHITECTURAL STYLE: RANCH STYLE 2 WOODEN BELLY BAND: BLACK IN COLOR FOR REAR WOODEN BELLY BAND: GRAY IN COLOR FOR BOTH NEW AND EXISTING 2 ROOF RIDGE ELEV:17'-0" 17 ' - 0 " 1389 POPPY WAY, CUPERTINO ROOF RIDGE ELEV:17'-0" 17 ' - 0 " 1373 POPPY WAY, CUPERTINO (N) ROOF RIDGE ELEV: 22'-4" 22 ' - 4 " (N) WOODEN BELLY BAND IN GRAY COLOR MATCHING THE SIDING (E) 16070 GARAGE DOOR (E) 10040 XOX SLIDING (E) STUCCO KEEP AS IS (E) SIDING PAINT TO LIGHT GRAY COLOR (E) 4030 SLIDING 4.5 12 4.5 12 4.5 12 4.5 12 4.5 12 4.5 12 W7 (E) ASPHALT SHINGLES TYP.(N) LIGHT FRENCH GRAY SIDING (E) WOODEN BELLY BAND AND PAINT WITH GRAY COLOR PROPERTY LINE PROPERTY LINE 1381 POPPY WAY, CUPERTINO SITE CROSS-SECTIONS SCALE: 1/8" = 1'-0" 11.02.23 Scale Drawing No. AS SHOWN Revision A l l i d e a s , d e s i g n s a n d p l a n s i n d i c a t e d o r r e p r e s e n t e d b y t h i s a r t a r e o w n e d b y a n d r e m a i n t h e p r o p e r t y u s e d o r d i s c l o s e d t o a n y o n e o f O p e n R e m o d e l . N o p a r t s h a l l b e Title Date w i t h o u t p e r m i s s i o n o f t h e C o m p a n y. No. Date RESIDENCE REMODEL Firm Name and Contact : Architecture | Home Designs www.openremodel.com contact@openremodel.com 408.357.3043 Th i s d r a w i n g h a s b e e n p r e p a r e d f o r t h e u s e o f O p e n R e m o d e l ( O R ) C l i e n t . I t m a y n o t b e u s e d , m o d i f i e d , r e p r o d u c e d , o r r e l i e d u p o n b y t h i r d p a r t i e s , e x c e p t a s a g r e e d b y O R o r a s r e q u i r e d b y l a w . O R a c c e p t s n o r e s p o n s i b i l i t y , a n d d e n i e s a n y l i a b i l i t y w h a t s o e v e r , t o a n y p a r t y t h a t u s e s o r r e l i e s o n t h i s d r a w i n g w i t h o u t O R ' s w r i t t e n c o n s e n t . D o n o t s c a l e t h i s d o c u m e n t . O n s i t e m e a s u r e m e n t s t o b e v e r i f i e d b y t h e C o n t r a c t o r . PR O J E C T A D D R E S S : HU E Y R E S I D E N C E R E M O D E L 13 8 1 P O P P Y W A Y , CU P E R T I N O , C A 9 5 0 1 4 Design Manager: Shweta Singh PLAN CHECK REVISION106-14-24 PLAN CHECK REVISION209-20-24 A7.0 PROP NORTH AND EAST ELEV R-2024-007 1/8/2025 Danielle Condit FLOOR FINISH ELEV: 1'-5"DINING ELEV: 0'-7" CEILING HT. ELEV:9'-5" 4.5 12 4.5 12 4.5 12 (E) ASPHALT SHINGLES TYP. (E) STUCCO WEST ELEVATION SCALE: 1/4" = 1'-0" (E) 6030 SLIDING 4.5 124.5 12 (E) 6030 SLIDING (N) ASPHALT SHINGLES TYP. (N) GRAY SIDING 8' - 0 " 1' - 5 " NATURAL GRADE LVL. ELEV: 0'-0" 9' - 5 " 1 S T F L O O R W A L L HE I G H T A T T O P O F W A L L P L A T E TEMPERED GLASST FROSTED OBSCURED GLASSO LEGEND: TEMPERED FROSTED OBSCURED GLASSTO PROPERTY LINE SIDE SETBACKSIDE SETBACK PROPERTY LINE BUILDING ENVELOPE (CMC Section 19.28.070) 5'-11"7'-3" 10 ' - 0 " 10 ' - 0 " 2 5 . 0 ° 25 . 0 ° (N) AC 3' - 8 " (N) SECOND FLOOR ELEV:10'-5" (N) SECOND FLOOR CEILING ELEV:18'-5" (N) ROOF RIDGE ELEV: 21'-10" 3' - 5 " 21 ' - 1 0 " T O T A L B U I L D I N G H E I G H T F R O M N A T U R A L G R A D E 8' - 0 " 1' - 0 " 18 ' - 5 " 2 N D F L O O R W A L L H E I G H T A T T O P O F W A L L P L A T E 1 1 (E) STUCCO KEEP AS IS 1' - 8 " W2 W4 2 2 (N) FLAT ROOF TO 2 FF T T D2 (N) WOODEN BELLY BAND IN BLACK COLOR MATCHING THE FASCIA FLOOR FINISH ELEV: 1'-5" SOUTH ELEVATION SCALE: 1/4" = 1'-0" CEILING HT. ELEV:9'-5" 4.5 12 DINING ELEV: 0'-7" AC EM (E) 2868 4.5 12 4.5 12 W3 W5 W6 (N) ASPHALT SHINGLES TYP.(N) ASPHALT SHINGLES TYP. (N) ASPHALT SHINGLES TYP. D1 8' - 0 " 1' - 5 " NATURAL GRADE LVL. ELEV: 0'-0" 9' - 5 " 1 S T F L O O R W A L L HE I G H T A T T O P O F W A L L P L A T E 7" (E) 3 TON AC RELOCATED TO T T F T T 3' - 8 " 5' - 2 " 5' - 2 " 1 (N) SECOND FLOOR ELEV:10'-5" (N) SECOND FLOOR CEILING ELEV:18'-5" (N) ROOF RIDGE ELEV: 21'-10" 3' - 5 " 21 ' - 1 0 " T O T A L B U I L D I N G H E I G H T F R O M N A T U R A L G R A D E 8' - 0 " 1' - 0 " 18 ' - 5 " 2 N D F L O O R W A L L H E I G H T A T T O P O F W A L L P L A T E 1 1 (N) GRAY SIDING (E) FASCIA PAINT WITH BLACK PAINT (N) GRAY SIDING (N) GRAY SIDING (N) BLACK FASCIA (E) STUCCO KEEP AS IS 1 1 2 (N) FLAT ROOF 2 (N) WOODEN BELLY BAND IN BLACK COLOR MATCHING THE FASCIA WHITE STUCCO PAINT: EXTERNAL WALL PAINT ALABASTER SW 7008 (V.I.F) EXISTING STUCCO KEEP AS IS. BLACK GUTTER: BLACK WINDOW TRIM AND FASCIA TRICORN BLACK SW 6258 GRAY SIDING: EXTERNAL GRAY PAINT LIGHT FRENCH GRAY SW 0055 EXISTING SIDING TO BE PAINTED WITH LIGHT GRAY PAINT. ASPHALT SHINGLES: MATCH WITH THE EXISTING HOUSE MATERIAL BOARD 1 ARCHITECTURAL STYLE: RANCH STYLE 2 WOODEN BELLY BAND: BLACK IN COLOR FOR REAR WOODEN BELLY BAND: GRAY IN COLOR FOR BOTH NEW AND EXISTING 2 11.02.23 Scale Drawing No. AS SHOWN Revision A l l i d e a s , d e s i g n s a n d p l a n s i n d i c a t e d o r r e p r e s e n t e d b y t h i s a r t a r e o w n e d b y a n d r e m a i n t h e p r o p e r t y u s e d o r d i s c l o s e d t o a n y o n e o f O p e n R e m o d e l . N o p a r t s h a l l b e Title Date w i t h o u t p e r m i s s i o n o f t h e C o m p a n y. No. Date RESIDENCE REMODEL Firm Name and Contact : Architecture | Home Designs www.openremodel.com contact@openremodel.com 408.357.3043 Th i s d r a w i n g h a s b e e n p r e p a r e d f o r t h e u s e o f O p e n R e m o d e l ( O R ) C l i e n t . I t m a y n o t b e u s e d , m o d i f i e d , r e p r o d u c e d , o r r e l i e d u p o n b y t h i r d p a r t i e s , e x c e p t a s a g r e e d b y O R o r a s r e q u i r e d b y l a w . O R a c c e p t s n o r e s p o n s i b i l i t y , a n d d e n i e s a n y l i a b i l i t y w h a t s o e v e r , t o a n y p a r t y t h a t u s e s o r r e l i e s o n t h i s d r a w i n g w i t h o u t O R ' s w r i t t e n c o n s e n t . D o n o t s c a l e t h i s d o c u m e n t . O n s i t e m e a s u r e m e n t s t o b e v e r i f i e d b y t h e C o n t r a c t o r . PR O J E C T A D D R E S S : HU E Y R E S I D E N C E R E M O D E L 13 8 1 P O P P Y W A Y , CU P E R T I N O , C A 9 5 0 1 4 Design Manager: Shweta Singh PLAN CHECK REVISION106-14-24 PLAN CHECK REVISION209-20-24 A8.0 PROP SOUTH AND WEST ELEV R-2024-007 1/8/2025 Danielle Condit WHOLE HOUSE VENTILATION: WHOLE HOUSE VENTILATION FAN TO CONTINUOUSLY RUN PER DESIGNED VENTILATION RATE. PROVIDE A LABEL AT CONTROL SWITCH WHICH READ "FAN TO BE LEFT ON FOR INDOOR AIR QUALITY". PROVIDE MAKEUP AIR AND COORDINATE ALL VENTILATION WITH FORCED AIR HVAC SYSTEM. 4"Ø EXHAUST DUCT THROUGH ROOF WITH RAIN CAP 4 BEDROOMS, 2645 SQ.FT. (INCLUDING ATTACHED GARAGE), REQUIRED QFAN = 0.03 X FLOOR + 7.5 (NBR +1) QFAN = 0.03 X 2645 + 7.5 (4+1) QFAN = 116.85 PROVIDE MINIMUM 117 CFM OF CONTINUOUS VENTILATION GENERAL NOTES: 1. CLEARANCE BETWEEN WOOD SIDING AND EARTH ON THE EXTERIOR OF THE BUILDING SHALL NOT BE LESS THAN 6" EXCEPT WHERE USING PRESERVATIVE-TREATED WOOD- CRC R317.1 2. THE CHIMNEY WILL TERMINATE A MINIMUM OF 2 FEET ABOVE ANY PART OF THE STRUCTURE WITHIN 10 FEET OF CHIMNEY TERMINATION AND SHALL BE EQUIPPED WITH AN APPROVED SPARK ARRESTER. 2022 CRC R1003.9 3. ALL FLASHINGS TO BE GA GI U.O.N 4. ALL GUTTERS TO BE GA GI U.O.N 5. ROOF IS CLASS "A" 6. ALL RAINWATER LEADERS IN THE WALLS AND POSTS TO BE OF CAST IRON 7. ALL VALLEY FLASHINGS TO BE 26 GA GI INSTALLED OVER A MIN. OF 36"W UNDERLAYMENT 8. ALL GUTTERS TO HAVE SCREENS 9. ALL WOOD FRAMING MEMBERS THAT REST ON THE EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8" FROM EXPOSED EARTH SHALL BE OF NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD. CRC R317.1 10. WOOD IN CONTACT WITH THE EARTH OR EMBEDDED IN CONCRETE MASONRY SHOULD BE PRESSURE TREATED. RESIDENTIAL HANDRAILS & GUARDS GUARDS 2016 CRC - SECTION R312 R312.1 GUARDS. GUARDS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS R312.1.1 THROUGH R312.1.4. R312.1.1 WHERE REQUIRED. GUARDS SHALL BE LOCATED ALONG OPEN-SIDED WALKING SURFACES INCLUDING STAIRS, RAMPS AND LANDINGS, THAT ARE LOCATED MORE THAN 30 INCHES MEASURED VERTICALLY TO THE FLOOR OR GRADE BELOW AT ANY POINT WITHIN 36 INCHES HORIZONTALLY TO THE EDGE OF THE OPEN SIDE. R312.1.2 HEIGHT REQUIRED GUARDS AT OPEN-SIDED WALKING SURFACES, INCLUDING STAIRS, PORCHES, BALCONIES OR LANDINGS, SHALL BE NOT LESS THAN 42 INCHES HIGH MEASURED VERTICALLY ABOVE THE ADJACENT WALKING SURFACE, ADJACENT FIXED SEATING OR THE LINE CONNECTING THE LEADING EDGES OF THE TREADS. EXCEPTIONS: 1. GUARDS ON THE OPEN SIDES OF STAIRS SHALL HAVE A HEIGHT NOT LESS THAN 34 INCHES MEASURED VERTICALLY FROM A LINE CONNECTING THE LEADING EDGES OF THE TREADS. 2. WHERE THE TOP OF THE GUARD ALSO SERVES AS A HANDRAIL ON THE OPEN SIDES OF STAIRS, THE TOP OF THE GUARD SHALL BE NOT LESS THAN 34 INCHES AND NOT MORE THAN 38 INCHES MEASURED VERTICALLY FROM A LINE CONNECTING THE LEADING EDGES OF THE TREADS. R312.1.3 OPENING LIMITATIONS. REQUIRED GUARDS SHALL NOT HAVE OPENINGS FROM THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT WHICH ALLOW PASSAGE OF A SPHERE 4 INCHES IN DIAMETER. EXCEPTIONS: 1. THE TRIANGULAR OPENINGS AT THE OPEN SIDE OF A STAIR, FORMED BY THE RISER, TREAD AND BOTTOM RAIL OF A GUARD, SHALL NOT ALLOW PASSAGE OF A SPHERE 6 INCHES IN DIAMETER. 2. GUARDS ON THE OPEN SIDES OF STAIRS SHALL NOT HAVE OPENINGS WHICH ALLOW PASSAGE OF A SPHERE 4-3/8 INCHES IN DIAMETER. ROOF VENT CALCULATION FOR NEW SECOND FLOOR: VENTING OF ATTIC SPACE CALCULATIONS AREA OF ATTIC = 647 SQ.FT. 647 / 150 = 4.31 SQ.FT. 4.31 X 144 = 620.64 OR 621 SQ.INCH REQUIRED ROOF VENTS: 621 / 2 = 310.5 SQ.INCH. 8 PROPOSED OFF RIDGE VENT (19"X4" BOX VENTS) = 8 X 43 (NFA) = 344 SQ. INCH ACHIEVED. TOTAL AREA OF EAVE VENTS = 310.5 SQ.INCH. AREA EAVE VENT SIZE 5.5" X 22" (75 SQ.INCH.), TOTAL NEEDED = 310.5 / 75 = 4.14 OR 5 VENTS NEEDED TOTAL PROVIDED VENTS = 5 VENTS 50% VENTING ACHIEVED BY THE LOW PROFILE DORMER VENTS AT A HEIGHT OF ABOVE 3' FROM THE EAVE. ENCLOSED ATTIC AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF FRAMING MEMBERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS. A MINIMUM OF 1" CLEAR AIRSPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING. BLOCKING SHALL BE ARRANGED TO NOT INTERFERE WITH THE MOVEMENT OF THE AIR. OPENINGS SHALL BE COVERED WITH CORROSION RESISTANT WIRE NOT EXCEEDING 1 4". ROOF VENT CALCULATION FOR GARAGE: VENTING OF ATTIC SPACE CALCULATIONS AREA OF ATTIC = 116 SQ.FT. 116 / 150 = 0.77 SQ.FT. 0.77 X 144 = 110.88 OR 111 SQ.INCH REQUIRED TOTAL AREA OF EAVE VENTS = 111 SQ.INCH. AREA EAVE VENT SIZE 5.5" X 22" (75 SQ.INCH.) TOTAL NEEDED = 111 / 75 = 1.48 OR 2 VENTS NEEDED TOTAL PROVIDED VENTS = 2 VENTS REPLACED GARAGE EXISTING 2 VENTS WITH NEW 2 VENTS. 50% VENTING ACHIEVED BY THE LOW PROFILE DORMER VENTS AT A HEIGHT OF ABOVE 3' FROM THE EAVE. ENCLOSED ATTIC AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF FRAMING MEMBERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS. A MINIMUM OF 1" CLEAR AIRSPACE SHALL BE PROVIDED BETWEEN THE INSULATION AND THE ROOF SHEATHING. BLOCKING SHALL BE ARRANGED TO NOT INTERFERE WITH THE MOVEMENT OF THE AIR. OPENINGS SHALL BE COVERED WITH CORROSION RESISTANT WIRE NOT EXCEEDING 1 4". REF. 4.5 12 4.5 124.5 12 CRAWL SPACE CRAWL SPACE (E) BEDROOM 1 (E) KITCHEN (E) DINING (N) LIVING AREA (SEE STRUCTURAL DRAWINGS) FOR ALL FOOTINGS AND FOUNDATION DETAILS (SEE STRUCTURAL DRAWINGS) FOR ALL FOOTINGS AND FOUNDATION DETAILS 5% SLOPE MINIMUM AT SOFTSCAPE 2% SLOPE MINIMUM AT HARDSCAPE 5% SLOPE MINIMUM AT SOFTSCAPE 2% SLOPE MINIMUM AT HARDSCAPE GALVANIZED 26 GA WEEP SCREED TYP. 4" MIN. ABOVE GRADE @ SOFTSCAPE 2" MIN. ABOVE GRADE @ HARDSCAPE 4.5 12 7 5 1 6 7 5 (E) ATTIC (N) ATTIC SECTION BB SCALE: 1/4" = 1'-0" CEILING HT. ELEV:9'-5" DINING ELEV: 0'-7" 1' - 6 " 8' - 0 " (E) ATTIC FLOOR FINISH ELEV: 1'-5" 8' - 0 " 7"NATURAL GRADE LVL. ELEV: 0'-0" 9' - 5 " 1 S T F L O O R W A L L HE I G H T A T T O P O F W A L L P L A T E 10 " (N) SECOND FLOOR ELEV:10'-5" (N) SECOND FLOOR CEILING ELEV:18'-5" (N) ROOF RIDGE ELEV: 21'-10" 3' - 5 " 21 ' - 1 0 " T O T A L B U I L D I N G H E I G H T F R O M N A T U R A L G R A D E 8' - 0 " 1' - 0 " 18 ' - 5 " 2 N D F L O O R W A L L H E I G H T A T T O P O F W A L L P L A T E 1 8' - 1 0 " 1 8' - 0 " ARCHITECTURAL STYLE: RANCH STYLE 2 2 2 CEILING HT. ELEV:9'-5" DINING ELEV: 0'-7" (E) GARAGE (E) DINING (N) LIVING AREA(N) BEDROOM 4 7 5 GALVANIZED 26 GA WEEP SCREED TYP. 4" MIN. ABOVE GRADE @ SOFTSCAPE 2" MIN. ABOVE GRADE @ HARDSCAPE 1 6 (SEE STRUCTURAL DRAWINGS) FOR ALL FOOTINGS AND FOUNDATION DETAILS (SEE STRUCTURAL DRAWINGS) FOR ALL FOOTINGS AND FOUNDATION DETAILS 5% SLOPE MINIMUM AT SOFTSCAPE 2% SLOPE MINIMUM AT HARDSCAPE SECTION AA SCALE: 1/4" = 1'-0" CABLE RAILING PER DETAIL A5.0 5% SLOPE MINIMUM AT SOFTSCAPE 2% SLOPE MINIMUM AT HARDSCAPE 8' - 1 0 " 8' - 0 " 4.5 12 (N) ASPHALT SHINGLES TYP. EXISTING NEW (N) ATTIC 8' - 1 0 " 7"NATURAL GRADE LVL. ELEV: 0'-0" 9' - 5 " 1 S T F L O O R W A L L HE I G H T A T T O P O F W A L L P L A T E (N) SECOND FLOOR ELEV:10'-5" (N) SECOND FLOOR CEILING ELEV:18'-5" (N) ROOF RIDGE ELEV: 21'-10" 3' - 5 " 21 ' - 1 0 " T O T A L B U I L D I N G H E I G H T F R O M N A T U R A L G R A D E 8' - 0 " 1' - 0 " 18 ' - 5 " 2 N D F L O O R W A L L H E I G H T A T T O P O F W A L L P L A T E 1 (N) BLACK BELLY BAND 1 WHOLE HOUSE VENTILATION: NOTE: ·1/2" GYPSUM BOARD FOR CEILING ·5/8" GYPSUM BOARD FOR WALLS ·1/2” GYPSUM BOARD TO PROTECT WALLS AND SOFFITS ON THE ENCLOSED SIDE (E.G. CLOSET,INTERIOR STAIRS,PANTRY, POWDER ROOM, ETC.) CRC R302.7 LEGEND: 1. ROOF COVERING OVER PLYWOOD SHEATHING. 2. EAVE VENTS (NET VENT AREA = 1/150 X ATTIC AREA.) 3. CEILING INSULATION R- 4. WALL INSULATION (MAIN HOUSE) R- 5. WALL COVERING OVER PLYWOOD SHEATHING. 6. RADIANT BARRIER 7. WALL INSULATION (ADU) R- 8. FLOOR INSULATION R- *** FLOOD VENT REQUIRED IF IN FLOOD ZONE (1 SQ. IN. FOR EVERY SQ. FT. CRAWL SPACE AREA) 11.02.23 Scale Drawing No. AS SHOWN Revision A l l i d e a s , d e s i g n s a n d p l a n s i n d i c a t e d o r r e p r e s e n t e d b y t h i s a r t a r e o w n e d b y a n d r e m a i n t h e p r o p e r t y u s e d o r d i s c l o s e d t o a n y o n e o f O p e n R e m o d e l . N o p a r t s h a l l b e Title Date w i t h o u t p e r m i s s i o n o f t h e C o m p a n y. No. Date RESIDENCE REMODEL Firm Name and Contact : Architecture | Home Designs www.openremodel.com contact@openremodel.com 408.357.3043 Th i s d r a w i n g h a s b e e n p r e p a r e d f o r t h e u s e o f O p e n R e m o d e l ( O R ) C l i e n t . I t m a y n o t b e u s e d , m o d i f i e d , r e p r o d u c e d , o r r e l i e d u p o n b y t h i r d p a r t i e s , e x c e p t a s a g r e e d b y O R o r a s r e q u i r e d b y l a w . O R a c c e p t s n o r e s p o n s i b i l i t y , a n d d e n i e s a n y l i a b i l i t y w h a t s o e v e r , t o a n y p a r t y t h a t u s e s o r r e l i e s o n t h i s d r a w i n g w i t h o u t O R ' s w r i t t e n c o n s e n t . D o n o t s c a l e t h i s d o c u m e n t . O n s i t e m e a s u r e m e n t s t o b e v e r i f i e d b y t h e C o n t r a c t o r . PR O J E C T A D D R E S S : HU E Y R E S I D E N C E R E M O D E L 13 8 1 P O P P Y W A Y , CU P E R T I N O , C A 9 5 0 1 4 Design Manager: Shweta Singh PLAN CHECK REVISION106-14-24 PLAN CHECK REVISION209-20-24 PROPOSED SECTIONS A9.0 R-2024-007 1/8/2025 Danielle Condit EM GM REF.CLG HT : 8'-0" (E) OPENING 7068 UP 2R@5" UP (E) DINING CLG HT : 8'-10" (E) LIVING ROOM CLG HT : 8'-0" (E) OPENING (E) BEDROOM 1 CLG HT : 8'-0" (E) BEDROOM 2 CLG HT : 8'-0" BEDROOM 3 CLG HT : 8'-0" (E) CLOSET (E ) C L O S E T (E) ATTIC ACCESS (E) BATH 1 (E) BATH 2 CLG HT : 8'-0" UP 1R@6" WH W D (E) ISLAND SHOWER TUB (E) GARAGE CLG HT : 9'-6" VAULTED CEILING (E ) 1 6 0 7 0 G A R A G E D O O R (E) SKY LIGHT LVL: 1'-5" LVL: 0'-0" LVL: 0'-7" LVL: 0'-0" UP 1R@7" (E) KITCHEN 16R@7.37" 15T@11"UP LVL: 0'-7" UP (N) LANDING LVL: 0'-0" AC (E ) C L O S E T (E) CLOSET LINE OF SECOND FLOOR ABOVE LINE OF SECOND FLOOR ABOVE LINE OF DEMOLITION CHIMNEY LINE OF DEMOLITION WALL (N) SLAB ON GRADE (E) SLAB ON GRADE (E) CRAWLSPACE 1R@5"&1R@6" (N ) A C DW FUTURE GARAGE EXPANSION TO MIN. CLEAR AREA, IN FUTURE, IF REQUIRED ELECTRICAL AND LIGHTING NOTES: 1. SYMBOLS LISTED ON LEGEND ARE FOR GENERAL USE AND DON'T NECESSARILY APPEAR ON ALL PLANS. DISREGARD ANY SYMBOL NOT INDICATED ON THE ELECTRICAL PLAN. 2. THESE NOTES SUPPLEMENT THOSE FOUND ELSEWHERE IN THESE DOCUMENTS; ALL REQUIREMENTS SHALL REMAIN IN FULL FORCE REGARDLESS OF WHERE THEY APPEAR, FOR ADDITIONAL INFORMATION & REQUIREMENTS, SEE OTHER SHEETS. 3. SUBMIT SHOP DRAWINGS PER NOTES 16& 17. SUBMIT ANY PROPOSED CHANGE OR DEVIATION FROM THESE NOTES & PLANS AS A SUBSTITUTION REQUEST OR RFI. 4. ALL 15-AMP & 20- AMP RECEPTACLES SHALL BE LISTED TAMPER- RESISTANT RECEPTACLES AND AFCI PROTECTED. ALL DEVICES & EQUIPMENT SHALL BE COMMERCIAL GRADE, LISTED BY A NATIONALLY RECOGNIZED TESTING LAB. ALL DEVICES & EQUIPMENT INSTALLED OUTDOORS AND/ OR EXPOSED TO WEATHER/MOISTURE SHALL BE OF WEATHERPROOF CONSTRUCTION& LISTED FOR SUCH USE. LIGHTING FIXTURES INSTALLED IN EXTERIOR LOCATIONS AND THOSE FOR USE IN DAMP LOCATIONS SHALL BE APPROVED FOR USE IN WET LOCATIONS, TYP. ALL 15 AND 20-AMP RECEPTACLES IN THE BATHROOMS SHALL BE GFCI PROTECTED CEC210.8. 5. PROVIDE GROUND FAULT CIRCUIT INTERRUPTER PROTECTION AT ALL LOCATIONS DENOTED & AT ALL LOCATIONS WHERE REQUIRED BY CODE . PROVIDE ARC-FAULT CIRCUIT INTERRUPTER PROTECTION AT ALL DWELLING UNIT OUTLETS NOT PROTECTED BY GFCI. 6. DIMENSIONS TO RECEPTACLES, SWITCHES AND ALL OTHER BOXES & DEVICES ARE FROM THE TOP OF THE FINISHED FLOOR SURFACE TO THE CENTERLINES OF THE DEVICE,UON. ELECTRICAL SWITCHES SHALL BE WALL MOUNTED 42" AFF, TYP.UON. 7. RECEPTACLES FOR ELECTRICAL POWER, TELEVISION, TELEPHONE, ETC. SHALL BE WALL MOUNTED 12" AFF AT INTERIOR WEATHER-PROTECTED LOCATIONS, WALL MOUNTED 42" AFF WHERE ABOVE BASE CABINETS. 18"(MIN) ABOVE FINISH FLOOR/ FINISH GRADE WHERE LOCATED OUTDOORS OR IN THE GARAGE, UNLESS OTHERWISE NOTED. 8. PROVIDE ELECTRICAL RECEPTACLES, SWITCHES, JACKS & ALL OTHER BOXES & DEVICES WITH MATCHING THERMOPLASTIC COVER PLATES, PROVIDE COVER PLATE GASKETS AT ALL BOXES & DEVICES LOCATED WITHIN EXTERIOR WALLS AND/OR INSULATED WALLS. WHERE MULTIPLE DEVICES OCCUR AT A SINGLE LOCATION, GANG DEVICES UNDER A SINGLE COVER PLATE. COLOR OF DEVICES& PLATES WILL BE SELECTED & CONFIRMED BY OWNER PRIOR TO INSTALLATION. 9. ALL EXTERIOR FIXTURES SHALL DIRECT LIGHT DOWNWARD & NOT REFLECT OR ENCROACH ON ADJACENT PROPERTIES. 10. ALL RECESSED LIGHT FIXTURES IN INSULATED CEILINGS SHALL BE AIRTIGHT AND I.C. RATED (ZERO- CLEARANCE) CALIFORNIA ENERGY CODE 150.0 (K) 1C. 11. PROVIDE LIGHTING FIXTURES WITH LAMPS OF APPROPRIATE WATTAGES & TYPES AS APPROVED BY FIXTURE MANUFACTURER, TYP.UON. 12. ALL HIGH EFFICACY FIXTURES SHALL BE FLUORESCENT OR CA CERTIFIED LED, LED FIXTURES REQD TO BE HIGH EFFICACY MUST BE CERTIFIED BY THE CA ENERGY COMMISSION & LISTED IN THE DATABASE AT www.appliances.energy.ca.gov. ALL LIGHTING FIXTURES SHALL BE CONTROLLED BY EITHER A DIMMER SWITCH OR A VACANCY SENSOR THAT REQUIRES MANUAL ACTIVATION AND AUTOMATICALLY TURNS OFF WITHIN 30 MINS AFTER THE ROOM IS VACATED. 13. PROVIDE ELECTRICAL RECEPTACLES SPACES MAX 12'-0" IN EVERY ROOM ON ALL WALLS 2'-0" OR ORE IN WIDTH . PROVIDE ONE RECEPTACLE(MIN) AT EACH HALLWAY. 14. PROVIDE SEPARATE SWITCH FOR LIGHT FIXTURES AND EXHAUST FAN(S) IN BATHROOMS, EXCEPT FOR COMBINATION UNITS WITHIN SHOWER STALLS & TUB/ SHOWER ENCLOSURE. 15. PROVIDE DEDICATED CIRCUIT FOR EACH DISHWASHER, MICROWAVE, STOVE, RANGE, WALL OVEN, GARBAGE DISPOSAL, REFRIGERATOR, CLOTHES DRYER, WATER HEATER, FURNACE, AIR CONDITIONER, & OTHER APPLIANCE/ EQUIPMENT AS REQD BY MANUFACTURER. 16. PROVIDE ONE DEDICATED 20 AMP CIRCUIT TO SERVE EACH BATHROOM. THIS CIRCUIT SHALL NOT SUPPLY ANY OTHER OUTLETS, RECEPTACLES, ETC. 17. PROVIDE TWO 20 AMP SMALL-APPLIANCE BRANCH CIRCUITS TO SERVE KITCHEN & DINING ROOM WALL & COUNTER RECEPTACLES ONLY. 18. PROVIDE A MINIMUM OF ONE 20 AMP RECEPTACLE FOR LAUNDRY. 19. PROVIDE UPDATED ACCURATE, & LEGIBLE CIRCUIT DIRECTORY ON FACE OR DOOR OF EACH PANEL BOARD/ SWITCHBOARD. LOCATE PANELS PER ALL CODE &LOCAL AHJ REQMNTS. 20. CONNECT MECH EQUIP W/24" MIN WEATHERPROOF FLEXIBLE CONDUIT. 21. SMOKE DETECTORS & CARBON MONOXIDE DETECTORS MUST BE 110V W/ BATTERY BACKUP, INTERCONNECTED, AUDIBLE IN ALL SLEEPING AREAS, & APPROVED & LISTED BY CA STATE FIRE MARSHAL, PROVIDE EVIDENCE OF SFM APPROVAL & LISTING TO BUILDING INSPECTOR PRIOR TO INSTALLATION. 22. WHIRLPOOL JETTED BATHTUB: PROVIDE UNIT LISTING BY UL, OAE, WITH ACCESS TO MOTOR, SELF-DRAINING PUMP& CIRCULATION PIPING TO MINIMIZE WATER RETENTION, SUCTION FITTINGS COMPLIANT W/LISTED STANDARDS, CIRCULATION PUMP LOCATED ABOVE CROWN WEIR OF TRAP, & SUPPLIED BY GFCI DEDICATED CIRCUIT, ALL METAL CABLES, FITTINGS, PIPING, ETC WITHIN 5 FT OF INSIDE TUB WALL SHALL BE PROPERLY BONDED W/MIN #8 AWG BARE COPPER WORE & BONDING SHALL BE ACCESSIBLE. 23. BATHROOM EXHAUST FANS MUST BE: ENERGY STAR COMPLIANT, DUCTED TO TERMINATE OUTSIDE BLDG, & CONTROLLED BY READILY ACCESSIBLE HUMIDISTAT. 24. CLOTHES DRYER EXHAUST WILL TERMINATE AT THE EXTERIOR OF THE BUILDING AND WILL BE MAX. 14' IN LENGTH WITH A MAX. OF TWO 90DEG. ELBOWS. 25. SEAL ALL ANNULAR SPACES AROUND PIPES, ELECTRICAL CABLES, CONDUITS OR OTHER OPENINGS IN SOLE/SILL/BOTTOM PLATES AT EXTERIOR WALLS WITH FLEXIBLE, DURABLE SEALANT MATERIAL, CEMENT MORTAR, CONCRETE MASONRY, OR SIMILAR ACCEPTABLE METHODS TO PROTECT AGAINST PASSAGE OF RODENTS. 26. THIS PLAN SHOWN SCHEMATICALLY, IS NOT COMPLETE DESIGN & DOES NOT REPRESENT ALL REQD ELEMENTS. THE ENTIRE ELECTRICAL SYSTEM SHALL BE DESIGNED BY A CALIFORNIA LICENSED ELECTRICAL CONTRACTOR PER ALL CA CODE & LOCAL AHJ REQUIREMENTS. 27. PROVIDE & SUBMIT MECHANICAL& HVAC PLANS/ SINGLE LINE DIAGRAMS, DESIGN & CALCULATIONS PREPARED BY LISCENSED MECHANICAL CONTRACTOR TO DESIGNER FOR REVIEW PRIOR TO INSTALLATION. 28. PROVIDE& MAINTAIN ON SITE PROJECT BINDER INCLUDING INSTALLATION INSTRUCTIONS & OWNER'S MANUALS FOR ALL SPECIFIED/ INSTALLED/ REQD EQUIPMENT. MAKE BINDER AVAILABLE TO FIELD INSPECTOR AT THE TIME OF INSPECTION, TO THE OWNER & DESIGNER UPON REQUEST, AND PRESENT TO OWNER UPON COMPLETION. 29. MECHANICAL EQUIPMENT INSTALLED IN ATTIC: THE EQUIPMENT SHALL NOT BE MORE THAN 20' FROM THE ATTIC OPENING WHERE LESS THAN 6' HEIGHT IS PROVIDED, A LIGHT SWITCH SHALL BE PROVIDED AT THE ACCESS, A RECEPTACLE SHALL BE PROVIDED AT THE EQUIPMENT FOR SERVICING THE EQUIPMENT. A 24" CLEAR WIDE PATH SHALL BE PROVIDED FROM THE ATTIC ACCESS TO THE EQUIPMENT AND 30"X30" PLATFORM SHALL BE PROVIDED IN FRONT OF THE EQUIPMENT. 30. UFER GROUND WILL BE INSTALLED FOR ALL MAIN AND SUB-ELECTRICAL PANELS CEC 250 31. ALL LIGHT FIXTURES SHALL CONTAIN BULBS THAT ARE LABELED AS JA8-2019. (JA8-2019-E FOR SEALED LENS OR RECESSED FIXTURE). SCREW BASE BULBS ARE PERMITTED, EXCEPT IN RECESSED LIGHTING FIXTURES. 32. CONDENSING UNIT SHALL BE LOCATED AND SECURED TO A MINIMUM THREE INCH THICK SLAB OR APPROVED PLATFORM. UNITS RATED UPTO 45,000 BTU/H SHALL HAVE A MINIMUM EFFICIENCY RATING OF 14 SEER AND 12.2 EER. 33. THE CONDENSATE LINE SHALL DRAIN TO A LANDSCAPED AREA OR TO THE TAIL PIECE OF A SANITARY SEWER LINE . 34. INSULATION ON THE SUCTION LINE (COOLING REFRIGERANT LINE) SHALL BE PROTECTED FROM PHYSICAL DAMAGE OR ULTRAVIOLET DETERIORATION BY AN ALUMINUM OR METAL SHROUD, PAINT, PLASTIC COVER OR ULTRAVIOLET RESISTANT TAPE- CEES 150.0(m)9 35. THE REFRIGERANT CIRCUIT ACCESS PORT SHALL BE PROTECTED FROM UNAUTHORIZED ACCESS WITH A LOCKING-TYPE TAMPER RESISTANT CAP- CMC 1105.11. 36. ALL ELECTRICAL RECEPTACLES SHALL BE TAMPER PROOF PER ARTICLE 406.12 AND 210.52 CEC201. ALL 125V, 15 AND 20 AMP RECEPTACLES FOR ALL AREAS OF SINGLE FAMILY HOMES. 37. ANTI-HAMMER DEVICE SHOULD BE INSTALLED AT DISHWASHER AND WASHER DRYER LOCATIONS TO ABSORB HIGH PRESSURES RESULTING FROM THE QUICK CLOSING OF QUICK-ACTING VALVES- CPC 609.10 38. ALL MECHANICAL, ELECTRICAL AND PLUMBING AND SIMILAR PENETRATIONS OF THE FLOOR OR TOP PLATES SHALL BE CAULKED WITH A RESIDENTIAL RATED FIRE CAULK WITH AN ASTM E136 RATING. 39. ALL PLASTIC CONDUIT OR CABLE IN 1 HR WALL SHALL BE "F" RATING. 40. ALL VENTILATION AND HEATING AND AIR CONDITIONING SYSTEMS TO HAVE MERV 6 FILTERS OR BETTER. 41. CENTRAL HEATING EQUIPMENTS TO HAVE DEDICATED CIRCUITS. A/S ARE PERMITTED TO USE THE SAME CIRCUIT. 42. INSTALL A DEDICATED FUEL SHUTOFF VALVE WITHING 6 FEET OF EACH GAS APPLIANCE ACCORDING TO CPC 1212.5 AND CMC 1313.4 43. SMOKE ALARMS SHALL NOT BE INSTALLED WITHIN 3' OF BATHROOM DOOR, FAN OR SUPPLY REGISTERS. IONIZATION SMOKE ALARMS MUST NOT BE INSTALLED WITHIN 20' HORIZONTAL OF COOKING APPLIANCES, PHOTOELECTRIC MAYBE INSTALLED WITHIN 10' HORIZONTAL OF COOKING APPLIANCES. 44. ALL PLUMBING VENTS SHALL TERMINATE NOT LESS THAN 6" ABOVE THE ROOF NOR LESS THAN 1' FROM ANY VERTICAL SURFACE. VENTS SHALL TERMINATE NOT LESS THAN 10" FROM OR 3' ABOVE ANY WINDOW, DOOR, OPENING, AIR INTAKE OR VENT SHAFT NOR 3' FROM LOT LINE- CPC 906 45. NON-REMOVABLE BACKFLOW PREVENTOR OR BIBB-TYPE VACUUM BREAKER WILL BE INSTALLED ON ALL EXTERIOR HOSE BIBS- CPC 603.4.7 46. IF THE WATER PRESSURE EXCEEDS 80PSI AND EXPANSION TANK AND AN APPROVED PRESSURE REGULATOR SHALL BE INSTALLED- CPC 608.2 47. THE MIXING VALVE IN A SHOWER (INCLUDING OVER A TUB) SHALL BE PRESSURE BALANCING SET AT A MAXIMUM 120 DEGREE F. THE WATER FILLER VALVE IN BATHTUBS/WHIRLPOOLS SHALL HAVE A TEMPERATURE LIMITING DEVICE SET AT A MAXIMUM OF 120 DEGREE F. THE WATER HEATER THERMOSTAT CANNOT BE USED TO MEET THESE PROVISIONS- CPC 408.3, 409.4 48. ALL DOMESTIC WATER PIPING INSULATION- ALL HOT WATER PIPING WITH A DIAMETER OF 3 4" OR LARGER. HOT WATER PIPING BURIED BELOW GRADE. ALL HOT WATER PIPES FROM THE WATER HEATER TO THE KITCHEN FIXTURES. 49. A SEDIMENT TRAP SHALL BE PROVIDED ON THE GAS LINE DOWNSTREAM OF THE APPLIANCE SHUT-OFF VALVE, AS CLOSE TOT HE INLET OF THE EQUIPMENT AS PRACTICAL, AND UPSTREAM OF THE FLEX CONNECTOR- CPC 1212.8 50. ALL OUTDOOR LIGHTING SHALL BE CONTROLLED BY A MANUAL "ON" AND "OFF" SWITCH AND CONTROLLED BY PHOTOCELL AND MOTION SENSOR. LANDING REQUIREMENT AND NOTE: ·DOORS OTHER THAN REQUIRED EGRESS DOOR SHALL BE PROVIDED WITH LANDINGS OR FLOORS NOT MORE THAN 7 3 4" BELOW THE TOP OF THE THRESHOLD. ·THE WIDTH OF EACH LANDING SHALL BE NOT LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A DIMENSION NOT LESS THAN 36 INCHES MEASURED IN THE DIRECTION OF TRAVEL. ·THE SLOPE AT EXTERIOR LANDINGS SHALL NOT EXCEED 1 4 UNIT VERTICAL IN 12 UNITS HORIZONTAL (2 PERCENT). DARK SKY COMPLIANCE NOTES: ·OUTDOOR ILLUMINATION TO BE SHIELDED AND DIRECTED DOWNWARD. ·LIGHTING AT ENTRANCES TO BUILDINGS MAY BE LIMITED TO A MAXIMUM FIXTURE HEIGHT OF EIGHT FEET, PEDESTRIAN LIGHTING (WALKWAYS) MAY BE LIMITED TO A HEIGHT BETWEEN THREE TO FIVE FEET. ·LIGHTING THAT HAS THE POTENTIAL FOR GREATER LIGHT AND GLARE ONTO ADJACENT PROPERTIES AND USES IS PROHIBITED. KEEPING ALL EXISTING EXTERIOR LIGHTING AND ELECTRICAL KEEPING ALL EXISTING EXTERIOR LIGHTING AND ELECTRICAL KEEPING ALL EXISTING EXTERIOR LIGHTING AND ELECTRICAL KE E P I N G A L L E X I S T I N G EX T E R I O R L I G H T I N G AN D E L E C T R I C A L KEEPING ALL EXISTING EXTERIOR LIGHTING AND ELECTRICAL KEEPING ALL EXISTING LIGHTING AND ELECTRICAL KEEPING ALL EXISTING LIGHTING AND ELECTRICAL KEEPING ALL EXISTING LIGHTING AND ELECTRICAL KEEPING ALL EXISTING LIGHTING AND ELECTRICAL KEEPING ALL EXISTING LIGHTING AND ELECTRICAL KEEPING ALL EXISTING LIGHTING AND ELECTRICAL KEEPING ALL EXISTING LIGHTING AND ELECTRICAL KEEPING ALL EXISTING LIGHTING AND ELECTRICAL KEEPING ALL EXISTING LIGHTING AND ELECTRICAL KEEPING ALL EXISTING LIGHTING AND ELECTRICAL KEEPING ALL EXISTING LIGHTING AND ELECTRICAL LED LED S P TO SECOND FLOOR SWITCH S4 S4 GFCI WP 220V 3'' MIN CONCRETE BASE OR HOUSEKEEPING PAD. [CMC 1105.2]AC DISCONNECT W/I SIGHT BUT NOT DIRECTLY BEHIND. S LED S³ 220V GFCI WP VS WP 220V RECEPTACLE OUTLET WATERPROOF EXTERIOR RECEPTACLE WITH BUBBLE COVERS TV OUTLET TELEPHONE OUTLET DATA OUTLET TELEDATA/STRUCTURE OUTLET VACANCY SENSOR SWITCH WATERPROOF/SHATTERPROOF FIXTURE CEILING LIGHT FIXTURE: SURFACE MOUNTED CEILING LIGHT FIXTURE: 6" LED RECESSED IC RATED CEILING LIGHT FIXTURE: 100 WATT INCANDESCENT IC RATED ADJUSTABLE DOWNLIGHT MS MOTION SENSOR LIGHT S S³ D³ SWITCH 2-WAY SWITCH DIMMER SWITCH GFCI RECEPTACLE OUTLET DUPLEX RECEPTACLE OUTLET -TAMPER RESISTANT 110V RECEPTACLE OUTLET GFCI LEGEND : 3-WAY SWITCHS4 USB RECEPTACLE OUTLETUSB USB+GFCI RECEPTACLE OUTLET USB GFCI LED EXISTING ELECTRICAL PROPOSED ELECTRICAL PROPOSED FIRST FLOOR MEP PLAN SCALE: 1/4"= 1'-0" GM SW-C EM FAUCET A/C EXTERNAL PART WATER METER SEWER CLEANOUT GAS METER ELECTRIC METER ELECTRIC PANELEP AC FT WM GENERAL ELECTRICAL NOTES: PROVIDE ARC-FAULT CIRCUIT INTERRUPTER AT ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT, SINGLE-PHASE, 15 AND 20 AMPERE RECEPTACLE OUTLETS INSTALLED INDWELLING UNIT FAMILY ROOMS, KITCHENS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, LAUNDRY ROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS. (CEC210.12 CA) ALL 125-VOLT, 15-AND 20-AMPERE RECEPTACLE OUTLETS SHALL BE LISTED TAMPER- RESISTANT RECEPTACLES (CEC 406.11) ALL 125-VOLT , SINGLE-PHASE, 15- AND 20-AMPERE RECEPTACLES INSTALLED IN THE FOLLOWING LOCATIONS SHALL HAVE GROUND-FAULT CIRCUIT INTERRUPTER PROTECTION FOR PERSONNEL (CEC 210.8):BATHROOMS, GARAGES, OUTDOORS, CRAWL SPACES, UNFINISHED BASEMENTS, LAUNDRY AREAS. KITCHEN COUNTERTOP SURFACES SINKS (WITHIN 6 FEET OF THE EDGE OF SINK) BOATHOUSES BATHTUBS/SHOWER STALLS (WITHIN 6 FEET OF EDGE OF TUB/SHOWER) PROVIDE AT LEAST ONE WEATHER-RESISTANT TYPE RECEPTACLE IN A WEATHERPROOF ENCLOSURE AT THE FRONT AND BACK OF THE DWELLING. (CEC 210.52 (E)(1) & 406.9 (B)(II)) COORDINATE LOCATION OF RETURNS, SUPPLY AND REGISTERS ON-SITE WITH CONTRACTOR AND MECHANICAL SUB CONTRACTOR P CEILING LIGHT FIXTURE: PENDANT LIGHT SMOKE DETECTORSD 120V SMOKE DETECTOR AND CARBON MONOXIDE DETECTOR WITH BATTERY BACKUP OUTSIDE BEDROOM CEILING FAN WITH CENTER LIGHT CSD EXHAUST FAN W/ PANASONIC WHISPER QUIET WITH LESS THAN 0.3 SONES AT 80 CFM AND 0.4 SONES AT 110 CFM, EXHAUST AIR FROM THE SPACE TO BE EXHAUSTED DIRECTLY TO THE OUTDOORS. [R303.3 EXCEPTION] F WALL MTD LIGHT FIXTURE CHANDELIER DOOR BELL CHIME FAUCET MOTION SENSOR LED WEATHER PROOF LIGHT FIXTURE SECURITY CAMERA EV CHARGER T THERMOSTAT BED SIDE LIGHT HVAC FLOOR VENT (PLACEMENT FOR REFERENCE ONLY) FOOD DISPOSAL SPOT LIGHT WI-FI (N) CONCEALED DUCTED MINI SPLIT AIR CONDITIONING AND HEAT PUMP DAIKIN FDMQ 12K BTU OUTDOOR UNIT MODEL #: RX12RMVJUA INDOOR UNIT MODEL #: FDMQ12RVJU SOUND (DBA) 51 (E) 3 TON AC RELOCATED 17 SEER OUTDOOR UNIT MODEL #: ML17XC1 SOUND (DBA) 73 WITH 5DB BRINMAR SOUND BLANKET GFCI WP 220V NOTE: ·ALL EXTERIOR OUTDOOR SCONCES LIGHT WILL BE THE HINKLEY LIGHTING WITH NIGHT SKY COMPLIANT. ·ALL OUTDOOR LIGHTING SHALL BE FULLY EXTINGUISHED OR BE MOTION SENSOR OPERATED BY 11:00 P.M. OR WHEN PEOPLE ARE NO LONGER PRESENT IN EXTERIOR AREAS. 1 1 1 11.02.23 Scale Drawing No. AS SHOWN Revision A l l i d e a s , d e s i g n s a n d p l a n s i n d i c a t e d o r r e p r e s e n t e d b y t h i s a r t a r e o w n e d b y a n d r e m a i n t h e p r o p e r t y u s e d o r d i s c l o s e d t o a n y o n e o f O p e n R e m o d e l . N o p a r t s h a l l b e Title Date w i t h o u t p e r m i s s i o n o f t h e C o m p a n y. No. Date RESIDENCE REMODEL Firm Name and Contact : Architecture | Home Designs www.openremodel.com contact@openremodel.com 408.357.3043 Th i s d r a w i n g h a s b e e n p r e p a r e d f o r t h e u s e o f O p e n R e m o d e l ( O R ) C l i e n t . I t m a y n o t b e u s e d , m o d i f i e d , r e p r o d u c e d , o r r e l i e d u p o n b y t h i r d p a r t i e s , e x c e p t a s a g r e e d b y O R o r a s r e q u i r e d b y l a w . O R a c c e p t s n o r e s p o n s i b i l i t y , a n d d e n i e s a n y l i a b i l i t y w h a t s o e v e r , t o a n y p a r t y t h a t u s e s o r r e l i e s o n t h i s d r a w i n g w i t h o u t O R ' s w r i t t e n c o n s e n t . D o n o t s c a l e t h i s d o c u m e n t . O n s i t e m e a s u r e m e n t s t o b e v e r i f i e d b y t h e C o n t r a c t o r . PR O J E C T A D D R E S S : HU E Y R E S I D E N C E R E M O D E L 13 8 1 P O P P Y W A Y , CU P E R T I N O , C A 9 5 0 1 4 Design Manager: Shweta Singh PLAN CHECK REVISION106-14-24 PLAN CHECK REVISION209-20-24 A11.0 PROP FIRST FLOOR MEP PLAN R-2024-007 1/8/2025 Danielle Condit DN LINE OF FIRST FLOOR BELOW (N) LIVING AREA CLG HT : 8'-0" (N) BEDROOM 4 CLG HT : 8'-0" (E) SKY LIGHT 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N SLOPE DN SLOPE DN (N) CRICKET (N) CRICKET 4.5:12 SLOPE DN (N) CLOSET (N) BATH 3 CLG HT : 8'-0" (N) BATH 4 CLG HT : 8'-0" LINE OF FIRST FLOOR BELOW LINE OF ROOF BELOW 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N 4. 5 : 1 2 SL O P E D N 4.5:12 SLOPE DN 4.5:12 SLOPE DN 4.5:12 SLOPE DN 16R@7.75" 15T@11" SKY LIGHT ABOVE TO FIRST FLOOR SWITCH S4 LED LED S³ USB WP LED F S VSD GF C I GFCI USB S WP S VS D GFCI USB S GF C I LED F USB LEDLED LED LED LED 2'-0"2'-0" 2' - 0 " 2' - 0 " D³ S³ MSMS US B US B US B LED LED LED LED LED LED LED LED LED D³S³ S³ S³ 2' - 0 " EQ EQ 2' - 0 " 2'-0"EQ EQ 2'-0" SCALE: 1/4" = 1'-0" PROPOSED SECOND FLOOR M.E.P PLAN ELECTRICAL AND LIGHTING NOTES: 1. SYMBOLS LISTED ON LEGEND ARE FOR GENERAL USE AND DON'T NECESSARILY APPEAR ON ALL PLANS. DISREGARD ANY SYMBOL NOT INDICATED ON THE ELECTRICAL PLAN. 2. THESE NOTES SUPPLEMENT THOSE FOUND ELSEWHERE IN THESE DOCUMENTS; ALL REQUIREMENTS SHALL REMAIN IN FULL FORCE REGARDLESS OF WHERE THEY APPEAR, FOR ADDITIONAL INFORMATION & REQUIREMENTS, SEE OTHER SHEETS. 3. SUBMIT SHOP DRAWINGS PER NOTES 16& 17. SUBMIT ANY PROPOSED CHANGE OR DEVIATION FROM THESE NOTES & PLANS AS A SUBSTITUTION REQUEST OR RFI. 4. ALL 15-AMP & 20- AMP RECEPTACLES SHALL BE LISTED TAMPER- RESISTANT RECEPTACLES AND AFCI PROTECTED. ALL DEVICES & EQUIPMENT SHALL BE COMMERCIAL GRADE, LISTED BY A NATIONALLY RECOGNIZED TESTING LAB. ALL DEVICES & EQUIPMENT INSTALLED OUTDOORS AND/ OR EXPOSED TO WEATHER/MOISTURE SHALL BE OF WEATHERPROOF CONSTRUCTION& LISTED FOR SUCH USE. LIGHTING FIXTURES INSTALLED IN EXTERIOR LOCATIONS AND THOSE FOR USE IN DAMP LOCATIONS SHALL BE APPROVED FOR USE IN WET LOCATIONS, TYP. ALL 15 AND 20-AMP RECEPTACLES IN THE BATHROOMS SHALL BE GFCI PROTECTED CEC210.8. 5. PROVIDE GROUND FAULT CIRCUIT INTERRUPTER PROTECTION AT ALL LOCATIONS DENOTED & AT ALL LOCATIONS WHERE REQUIRED BY CODE . PROVIDE ARC-FAULT CIRCUIT INTERRUPTER PROTECTION AT ALL DWELLING UNIT OUTLETS NOT PROTECTED BY GFCI. 6. DIMENSIONS TO RECEPTACLES, SWITCHES AND ALL OTHER BOXES & DEVICES ARE FROM THE TOP OF THE FINISHED FLOOR SURFACE TO THE CENTERLINES OF THE DEVICE,UON. ELECTRICAL SWITCHES SHALL BE WALL MOUNTED 42" AFF, TYP.UON. 7. RECEPTACLES FOR ELECTRICAL POWER, TELEVISION, TELEPHONE, ETC. SHALL BE WALL MOUNTED 12" AFF AT INTERIOR WEATHER-PROTECTED LOCATIONS, WALL MOUNTED 42" AFF WHERE ABOVE BASE CABINETS. 18"(MIN) ABOVE FINISH FLOOR/ FINISH GRADE WHERE LOCATED OUTDOORS OR IN THE GARAGE, UNLESS OTHERWISE NOTED. 8. PROVIDE ELECTRICAL RECEPTACLES, SWITCHES, JACKS & ALL OTHER BOXES & DEVICES WITH MATCHING THERMOPLASTIC COVER PLATES, PROVIDE COVER PLATE GASKETS AT ALL BOXES & DEVICES LOCATED WITHIN EXTERIOR WALLS AND/OR INSULATED WALLS. WHERE MULTIPLE DEVICES OCCUR AT A SINGLE LOCATION, GANG DEVICES UNDER A SINGLE COVER PLATE. COLOR OF DEVICES& PLATES WILL BE SELECTED & CONFIRMED BY OWNER PRIOR TO INSTALLATION. 9. ALL EXTERIOR FIXTURES SHALL DIRECT LIGHT DOWNWARD & NOT REFLECT OR ENCROACH ON ADJACENT PROPERTIES. 10. ALL RECESSED LIGHT FIXTURES IN INSULATED CEILINGS SHALL BE AIRTIGHT AND I.C. RATED (ZERO- CLEARANCE) CALIFORNIA ENERGY CODE 150.0 (K) 1C. 11. PROVIDE LIGHTING FIXTURES WITH LAMPS OF APPROPRIATE WATTAGES & TYPES AS APPROVED BY FIXTURE MANUFACTURER, TYP.UON. 12. ALL HIGH EFFICACY FIXTURES SHALL BE FLUORESCENT OR CA CERTIFIED LED, LED FIXTURES REQD TO BE HIGH EFFICACY MUST BE CERTIFIED BY THE CA ENERGY COMMISSION & LISTED IN THE DATABASE AT www.appliances.energy.ca.gov. ALL LIGHTING FIXTURES SHALL BE CONTROLLED BY EITHER A DIMMER SWITCH OR A VACANCY SENSOR THAT REQUIRES MANUAL ACTIVATION AND AUTOMATICALLY TURNS OFF WITHIN 30 MINS AFTER THE ROOM IS VACATED. 13. PROVIDE ELECTRICAL RECEPTACLES SPACES MAX 12'-0" IN EVERY ROOM ON ALL WALLS 2'-0" OR ORE IN WIDTH . PROVIDE ONE RECEPTACLE(MIN) AT EACH HALLWAY. 14. PROVIDE SEPARATE SWITCH FOR LIGHT FIXTURES AND EXHAUST FAN(S) IN BATHROOMS, EXCEPT FOR COMBINATION UNITS WITHIN SHOWER STALLS & TUB/ SHOWER ENCLOSURE. 15. PROVIDE DEDICATED CIRCUIT FOR EACH DISHWASHER, MICROWAVE, STOVE, RANGE, WALL OVEN, GARBAGE DISPOSAL, REFRIGERATOR, CLOTHES DRYER, WATER HEATER, FURNACE, AIR CONDITIONER, & OTHER APPLIANCE/ EQUIPMENT AS REQD BY MANUFACTURER. 16. PROVIDE ONE DEDICATED 20 AMP CIRCUIT TO SERVE EACH BATHROOM. THIS CIRCUIT SHALL NOT SUPPLY ANY OTHER OUTLETS, RECEPTACLES, ETC. 17. PROVIDE TWO 20 AMP SMALL-APPLIANCE BRANCH CIRCUITS TO SERVE KITCHEN & DINING ROOM WALL & COUNTER RECEPTACLES ONLY. 18. PROVIDE A MINIMUM OF ONE 20 AMP RECEPTACLE FOR LAUNDRY. 19. PROVIDE UPDATED ACCURATE, & LEGIBLE CIRCUIT DIRECTORY ON FACE OR DOOR OF EACH PANEL BOARD/ SWITCHBOARD. LOCATE PANELS PER ALL CODE &LOCAL AHJ REQMNTS. 20. CONNECT MECH EQUIP W/24" MIN WEATHERPROOF FLEXIBLE CONDUIT. 21. SMOKE DETECTORS & CARBON MONOXIDE DETECTORS MUST BE 110V W/ BATTERY BACKUP, INTERCONNECTED, AUDIBLE IN ALL SLEEPING AREAS, & APPROVED & LISTED BY CA STATE FIRE MARSHAL, PROVIDE EVIDENCE OF SFM APPROVAL & LISTING TO BUILDING INSPECTOR PRIOR TO INSTALLATION. 22. WHIRLPOOL JETTED BATHTUB: PROVIDE UNIT LISTING BY UL, OAE, WITH ACCESS TO MOTOR, SELF-DRAINING PUMP& CIRCULATION PIPING TO MINIMIZE WATER RETENTION, SUCTION FITTINGS COMPLIANT W/LISTED STANDARDS, CIRCULATION PUMP LOCATED ABOVE CROWN WEIR OF TRAP, & SUPPLIED BY GFCI DEDICATED CIRCUIT, ALL METAL CABLES, FITTINGS, PIPING, ETC WITHIN 5 FT OF INSIDE TUB WALL SHALL BE PROPERLY BONDED W/MIN #8 AWG BARE COPPER WORE & BONDING SHALL BE ACCESSIBLE. 23. BATHROOM EXHAUST FANS MUST BE: ENERGY STAR COMPLIANT, DUCTED TO TERMINATE OUTSIDE BLDG, & CONTROLLED BY READILY ACCESSIBLE HUMIDISTAT. 24. CLOTHES DRYER EXHAUST WILL TERMINATE AT THE EXTERIOR OF THE BUILDING AND WILL BE MAX. 14' IN LENGTH WITH A MAX. OF TWO 90DEG. ELBOWS. 25. SEAL ALL ANNULAR SPACES AROUND PIPES, ELECTRICAL CABLES, CONDUITS OR OTHER OPENINGS IN SOLE/SILL/BOTTOM PLATES AT EXTERIOR WALLS WITH FLEXIBLE, DURABLE SEALANT MATERIAL, CEMENT MORTAR, CONCRETE MASONRY, OR SIMILAR ACCEPTABLE METHODS TO PROTECT AGAINST PASSAGE OF RODENTS. 26. THIS PLAN SHOWN SCHEMATICALLY, IS NOT COMPLETE DESIGN & DOES NOT REPRESENT ALL REQD ELEMENTS. THE ENTIRE ELECTRICAL SYSTEM SHALL BE DESIGNED BY A CALIFORNIA LICENSED ELECTRICAL CONTRACTOR PER ALL CA CODE & LOCAL AHJ REQUIREMENTS. 27. PROVIDE & SUBMIT MECHANICAL& HVAC PLANS/ SINGLE LINE DIAGRAMS, DESIGN & CALCULATIONS PREPARED BY LISCENSED MECHANICAL CONTRACTOR TO DESIGNER FOR REVIEW PRIOR TO INSTALLATION. 28. PROVIDE& MAINTAIN ON SITE PROJECT BINDER INCLUDING INSTALLATION INSTRUCTIONS & OWNER'S MANUALS FOR ALL SPECIFIED/ INSTALLED/ REQD EQUIPMENT. MAKE BINDER AVAILABLE TO FIELD INSPECTOR AT THE TIME OF INSPECTION, TO THE OWNER & DESIGNER UPON REQUEST, AND PRESENT TO OWNER UPON COMPLETION. 29. MECHANICAL EQUIPMENT INSTALLED IN ATTIC: THE EQUIPMENT SHALL NOT BE MORE THAN 20' FROM THE ATTIC OPENING WHERE LESS THAN 6' HEIGHT IS PROVIDED, A LIGHT SWITCH SHALL BE PROVIDED AT THE ACCESS, A RECEPTACLE SHALL BE PROVIDED AT THE EQUIPMENT FOR SERVICING THE EQUIPMENT. A 24" CLEAR WIDE PATH SHALL BE PROVIDED FROM THE ATTIC ACCESS TO THE EQUIPMENT AND 30"X30" PLATFORM SHALL BE PROVIDED IN FRONT OF THE EQUIPMENT. 30. UFER GROUND WILL BE INSTALLED FOR ALL MAIN AND SUB-ELECTRICAL PANELS CEC 250 31. ALL LIGHT FIXTURES SHALL CONTAIN BULBS THAT ARE LABELED AS JA8-2019. (JA8-2019-E FOR SEALED LENS OR RECESSED FIXTURE). SCREW BASE BULBS ARE PERMITTED, EXCEPT IN RECESSED LIGHTING FIXTURES. 32. CONDENSING UNIT SHALL BE LOCATED AND SECURED TO A MINIMUM THREE INCH THICK SLAB OR APPROVED PLATFORM. UNITS RATED UPTO 45,000 BTU/H SHALL HAVE A MINIMUM EFFICIENCY RATING OF 14 SEER AND 12.2 EER. 33. THE CONDENSATE LINE SHALL DRAIN TO A LANDSCAPED AREA OR TO THE TAIL PIECE OF A SANITARY SEWER LINE . 34. INSULATION ON THE SUCTION LINE (COOLING REFRIGERANT LINE) SHALL BE PROTECTED FROM PHYSICAL DAMAGE OR ULTRAVIOLET DETERIORATION BY AN ALUMINUM OR METAL SHROUD, PAINT, PLASTIC COVER OR ULTRAVIOLET RESISTANT TAPE- CEES 150.0(m)9 35. THE REFRIGERANT CIRCUIT ACCESS PORT SHALL BE PROTECTED FROM UNAUTHORIZED ACCESS WITH A LOCKING-TYPE TAMPER RESISTANT CAP- CMC 1105.11. 36. ALL ELECTRICAL RECEPTACLES SHALL BE TAMPER PROOF PER ARTICLE 406.12 AND 210.52 CEC201. ALL 125V, 15 AND 20 AMP RECEPTACLES FOR ALL AREAS OF SINGLE FAMILY HOMES. 37. ANTI-HAMMER DEVICE SHOULD BE INSTALLED AT DISHWASHER AND WASHER DRYER LOCATIONS TO ABSORB HIGH PRESSURES RESULTING FROM THE QUICK CLOSING OF QUICK-ACTING VALVES- CPC 609.10 38. ALL MECHANICAL, ELECTRICAL AND PLUMBING AND SIMILAR PENETRATIONS OF THE FLOOR OR TOP PLATES SHALL BE CAULKED WITH A RESIDENTIAL RATED FIRE CAULK WITH AN ASTM E136 RATING. 39. ALL PLASTIC CONDUIT OR CABLE IN 1 HR WALL SHALL BE "F" RATING. 40. ALL VENTILATION AND HEATING AND AIR CONDITIONING SYSTEMS TO HAVE MERV 6 FILTERS OR BETTER. 41. CENTRAL HEATING EQUIPMENTS TO HAVE DEDICATED CIRCUITS. A/S ARE PERMITTED TO USE THE SAME CIRCUIT. 42. INSTALL A DEDICATED FUEL SHUTOFF VALVE WITHING 6 FEET OF EACH GAS APPLIANCE ACCORDING TO CPC 1212.5 AND CMC 1313.4 43. SMOKE ALARMS SHALL NOT BE INSTALLED WITHIN 3' OF BATHROOM DOOR, FAN OR SUPPLY REGISTERS. IONIZATION SMOKE ALARMS MUST NOT BE INSTALLED WITHIN 20' HORIZONTAL OF COOKING APPLIANCES, PHOTOELECTRIC MAYBE INSTALLED WITHIN 10' HORIZONTAL OF COOKING APPLIANCES. 44. ALL PLUMBING VENTS SHALL TERMINATE NOT LESS THAN 6" ABOVE THE ROOF NOR LESS THAN 1' FROM ANY VERTICAL SURFACE. VENTS SHALL TERMINATE NOT LESS THAN 10" FROM OR 3' ABOVE ANY WINDOW, DOOR, OPENING, AIR INTAKE OR VENT SHAFT NOR 3' FROM LOT LINE- CPC 906 45. NON-REMOVABLE BACKFLOW PREVENTOR OR BIBB-TYPE VACUUM BREAKER WILL BE INSTALLED ON ALL EXTERIOR HOSE BIBS- CPC 603.4.7 46. IF THE WATER PRESSURE EXCEEDS 80PSI AND EXPANSION TANK AND AN APPROVED PRESSURE REGULATOR SHALL BE INSTALLED- CPC 608.2 47. THE MIXING VALVE IN A SHOWER (INCLUDING OVER A TUB) SHALL BE PRESSURE BALANCING SET AT A MAXIMUM 120 DEGREE F. THE WATER FILLER VALVE IN BATHTUBS/WHIRLPOOLS SHALL HAVE A TEMPERATURE LIMITING DEVICE SET AT A MAXIMUM OF 120 DEGREE F. THE WATER HEATER THERMOSTAT CANNOT BE USED TO MEET THESE PROVISIONS- CPC 408.3, 409.4 48. ALL DOMESTIC WATER PIPING INSULATION- ALL HOT WATER PIPING WITH A DIAMETER OF 3 4" OR LARGER. HOT WATER PIPING BURIED BELOW GRADE. ALL HOT WATER PIPES FROM THE WATER HEATER TO THE KITCHEN FIXTURES. 49. A SEDIMENT TRAP SHALL BE PROVIDED ON THE GAS LINE DOWNSTREAM OF THE APPLIANCE SHUT-OFF VALVE, AS CLOSE TOT HE INLET OF THE EQUIPMENT AS PRACTICAL, AND UPSTREAM OF THE FLEX CONNECTOR- CPC 1212.8 50. ALL OUTDOOR LIGHTING SHALL BE CONTROLLED BY A MANUAL "ON" AND "OFF" SWITCH AND CONTROLLED BY PHOTOCELL AND MOTION SENSOR. PRESCRIPTIVE PLUMBING FIXTURE REQUIREMENTS CGBC 4.303.1: 1. WATERS CLOSETS: ≤ 1.28 GAL/FLUSH. CGBSC 4.303.1.1 2. SINGLE SHOWERHEADS: ≤ 1.8 GPM @ 80 PSI. CGBSC 4.303.1.3 3. MULTIPLE SHOWERHEADS: COMBINED FLOW RATE OF ALL SHOWERHEADS AND/OR OTHER SHOWER OUTLETS CONTROLLED BY A SINGLE VALVE SHALL NOT EXCEED 1.8 GPM @ 80 PSI OR ONLY ONE SHOWER OUTLET IS TO BE IN OPERATION AT A TIME. CGBSC 4.303.1.3.2 4. RESIDENTIAL LAVATORY AUCETS: ≤ 1.2 GPM @ 60 PSI. CGBSC 4.303.1.4.1 5. KITCHEN FAUCETS: ≤ 1.8 GPM @ 60 PSI; TEMPORARY INCREASE TO 2.2 GPM ALLOWED BUT SHALL DEFAULT TO 1.8 GPM. 4.303.1.4.4 GENERAL ELECTRICAL NOTES: PROVIDE ARC-FAULT CIRCUIT INTERRUPTER AT ALL BRANCH CIRCUITS THAT SUPPLY 125 VOLT, SINGLE-PHASE, 15 AND 20 AMPERE RECEPTACLE OUTLETS INSTALLED INDWELLING UNIT FAMILY ROOMS, KITCHENS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, LAUNDRY ROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS. (CEC210.12 CA) ALL 125-VOLT, 15-AND 20-AMPERE RECEPTACLE OUTLETS SHALL BE LISTED TAMPER- RESISTANT RECEPTACLES (CEC 406.11) ALL 125-VOLT , SINGLE-PHASE, 15- AND 20-AMPERE RECEPTACLES INSTALLED IN THE FOLLOWING LOCATIONS SHALL HAVE GROUND-FAULT CIRCUIT INTERRUPTER PROTECTION FOR PERSONNEL (CEC 210.8):BATHROOMS, GARAGES, OUTDOORS, CRAWL SPACES, UNFINISHED BASEMENTS, LAUNDRY AREAS. KITCHEN COUNTERTOP SURFACES SINKS (WITHIN 6 FEET OF THE EDGE OF SINK) BOATHOUSES BATHTUBS/SHOWER STALLS (WITHIN 6 FEET OF EDGE OF TUB/SHOWER) PROVIDE AT LEAST ONE WEATHER-RESISTANT TYPE RECEPTACLE IN A WEATHERPROOF ENCLOSURE AT THE FRONT AND BACK OF THE DWELLING. (CEC 210.52 (E)(1) & 406.9 (B)(II)) COORDINATE LOCATION OF RETURNS, SUPPLY AND REGISTERS ON-SITE WITH CONTRACTOR AND MECHANICAL SUB CONTRACTOR NOTE: ALL ROOMS TO BE PROVIDED WITH EATING/COOLING VENTS. TO BE DESIGNED BY MANUAL J&D. FOR DRYER VENT TO EXTERIOR NOT W/I 3' OF ANY OPENING. KITCHEN EXHAUST VENT TO EXTERIOR NOT WITHIN 3' OF ANY OPENING. 220V GFCI WP VS WP P 220V RECEPTACLE OUTLET WATERPROOF EXTERIOR RECEPTACLE WITH BUBBLE COVERS TV OUTLET TELEPHONE OUTLET DATA OUTLET TELEDATA/STRUCTURE OUTLET VACANCY SENSOR SWITCH WATERPROOF/SHATTERPROOF FIXTURE CEILING LIGHT FIXTURE: SURFACE MOUNTED CEILING LIGHT FIXTURE: 6" LED RECESSED IC RATED CEILING LIGHT FIXTURE: 100 WATT INCANDESCENT IC RATED CEILING LIGHT FIXTURE: PENDANT LIGHT SMOKE DETECTORSD 120V SMOKE DETECTOR AND CARBON MONOXIDE DETECTOR WITH BATTERY BACKUP OUTSIDE BEDROOM CEILING FAN WITH CENTER LIGHT ADJUSTABLE DOWNLIGHT CSD EXHAUST FAN W/ PANASONIC WHISPER QUIET WITH LESS THAN 0.3 SONES AT 80 CFM AND 0.4 SONES AT 110 CFM, EXHAUST AIR FROM THE SPACE TO BE EXHAUSTED DIRECTLY TO THE OUTDOORS. [R303.3 EXCEPTION] F WALL MTD LIGHT FIXTURE CHANDELIER DOOR BELL CHIME FAUCET MOTION SENSOR LED WEATHER PROOF LIGHT FIXTURE SECURITY CAMERA MS MOTION SENSOR LIGHT EV CHARGER T THERMOSTAT BED SIDE LIGHT HVAC FLOOR VENT (PLACEMENT FOR REFERENCE ONLY) S S³ D³ SWITCH 2-WAY SWITCH DIMMER SWITCH GFCI RECEPTACLE OUTLET DUPLEX RECEPTACLE OUTLET -TAMPER RESISTANT 110V RECEPTACLE OUTLET GFCI LEGEND : 3-WAY SWITCHS4 FOOD DISPOSAL SPOT LIGHT USB RECEPTACLE OUTLETUSB USB+GFCI RECEPTACLE OUTLET USB GFCI LED WI-FI EXISTING ELECTRICAL PROPOSED ELECTRICAL BATHROOM SPECIFIC NOTES: A. REQUIRED CLEARANCES ARE 24” IN FRONT AND 15” FROM CENTERLINE TO WALL OR CABINET. (30” TOTAL) (CPC SEC. 402.5) B. WHERE THE WATER CLOSET (OR OTHER PLUMBING FIXTURE) COMES INTO CONTACT WITH THE WALL OR FLOOR, THE JOINT SHALL BE CAULKED AND SEALED TO BE WATERTIGHT. (CPC 402.2) C. NEW OR ALTERED SHOWER COMPARTMENTS SHALL HAVE A MINIMUM FINISHEDDAM, CURB, OR THRESHOLD NOT LESS THAN 2 INCHES OR EXCEEDING 9 INCHES IN DEPTH, WITH AN INTERIOR OF 1,024 SQUARE INCHES AND SHALL ALSO BE CAPABLE OF ENCOMPASSING A 30-INCH DIAMETER CIRCLE MEASURED TO THE CENTER OF THE THRESHOLD. (CPC SEC.408.5 & CPC SEC. 408.6). 1. SHOWER ENTRANCE SHALL BE PROVIDED WITH A MINIMUM OF 22” CLEAR OPENING AND,IF FEATURED WITH A DOOR SHALL BE SLIDING OR OUTWARD SWING. 2. ANY GLAZING WITHIN 60” RADIUS OF TUB/SHOWER ENCLOSURES SHALL BE TEMPERED SAFETY GLASS (BATHROOMS INCLUSIVE OF SHOWERS SHALL HAVE ALL GLAZING TEMPERED SAFETY GLASS) 3. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH A PRESSURE / BALANCE THERMOSTATIC MIXING VALVE. MAX FLOW OF ANY SHOWER HEADS OR HANDHELD OUTLETS CONTROLLED BY DIVERTER VALVE SHALL BE 1.8 G.P.M.COMBINED. 4. SHOWER COMPARTMENTS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS SHALL BE FINISHED WITH A SMOOTH, NONABSORBENT SURFACE TO A HEIGHT NOT LESS THAN 72 INCHES (6 FT). (CRC R307.2) 5. SHOWER COMPARTMENT SHALL BE A MINIMUM 1,024 SQUARE INCHES ENCOMPASSING A 30" DIA. CIRCLE. (CPC 408.5 & 408.6) WATER EFFICIENT PLUMBING FIXTURES (CALIFORNIA CIVIL CODE 1101.4(A)) : RESIDENTIAL PROPERTY BUILT AND AVAILABLE FOR USE OR OCCUPANCY ON OR BEFORE JANUARY 1, 1994, BE EQUIPPED WITH WATER-CONSERVING PLUMBING FIXTURES.ON OR BEFORE JANUARY 1, 2017, NONCOMPLIANT PLUMBING FIXTURES IN ANY SINGLE-FAMILY RESIDENTIAL REAL PROPERTY SHALL BE REPLACED BY THE PROPERTY OWNER WITH WATER-CONSERVING PLUMBING FIXTURES. Type of Fixture Required Water-Conserving Plumbing Fixture (maximum flow rates) Water Closet (Toilet) 1.28 gpf Showerhead 1.80 gpm Lavatory Faucets 1.20 gpm Kitchen Faucets 1.80 gpm 11.02.23 Scale Drawing No. AS SHOWN Revision A l l i d e a s , d e s i g n s a n d p l a n s i n d i c a t e d o r r e p r e s e n t e d b y t h i s a r t a r e o w n e d b y a n d r e m a i n t h e p r o p e r t y u s e d o r d i s c l o s e d t o a n y o n e o f O p e n R e m o d e l . N o p a r t s h a l l b e Title Date w i t h o u t p e r m i s s i o n o f t h e C o m p a n y. No. Date RESIDENCE REMODEL Firm Name and Contact : Architecture | Home Designs www.openremodel.com contact@openremodel.com 408.357.3043 Th i s d r a w i n g h a s b e e n p r e p a r e d f o r t h e u s e o f O p e n R e m o d e l ( O R ) C l i e n t . I t m a y n o t b e u s e d , m o d i f i e d , r e p r o d u c e d , o r r e l i e d u p o n b y t h i r d p a r t i e s , e x c e p t a s a g r e e d b y O R o r a s r e q u i r e d b y l a w . O R a c c e p t s n o r e s p o n s i b i l i t y , a n d d e n i e s a n y l i a b i l i t y w h a t s o e v e r , t o a n y p a r t y t h a t u s e s o r r e l i e s o n t h i s d r a w i n g w i t h o u t O R ' s w r i t t e n c o n s e n t . D o n o t s c a l e t h i s d o c u m e n t . O n s i t e m e a s u r e m e n t s t o b e v e r i f i e d b y t h e C o n t r a c t o r . PR O J E C T A D D R E S S : HU E Y R E S I D E N C E R E M O D E L 13 8 1 P O P P Y W A Y , CU P E R T I N O , C A 9 5 0 1 4 Design Manager: Shweta Singh PLAN CHECK REVISION106-14-24 PLAN CHECK REVISION209-20-24 A12.0 PROP SECOND FLOOR MEP PLAN R-2024-007 1/8/2025 Danielle Condit 11.02.23 Scale Drawing No. AS SHOWN Revision A l l i d e a s , d e s i g n s a n d p l a n s i n d i c a t e d o r r e p r e s e n t e d b y t h i s a r t a r e o w n e d b y a n d r e m a i n t h e p r o p e r t y u s e d o r d i s c l o s e d t o a n y o n e o f O p e n R e m o d e l . N o p a r t s h a l l b e Title Date w i t h o u t p e r m i s s i o n o f t h e C o m p a n y. No. Date RESIDENCE REMODEL Firm Name and Contact : Architecture | Home Designs www.openremodel.com contact@openremodel.com 408.357.3043 Th i s d r a w i n g h a s b e e n p r e p a r e d f o r t h e u s e o f O p e n R e m o d e l ( O R ) C l i e n t . I t m a y n o t b e u s e d , m o d i f i e d , r e p r o d u c e d , o r r e l i e d u p o n b y t h i r d p a r t i e s , e x c e p t a s a g r e e d b y O R o r a s r e q u i r e d b y l a w . O R a c c e p t s n o r e s p o n s i b i l i t y , a n d d e n i e s a n y l i a b i l i t y w h a t s o e v e r , t o a n y p a r t y t h a t u s e s o r r e l i e s o n t h i s d r a w i n g w i t h o u t O R ' s w r i t t e n c o n s e n t . D o n o t s c a l e t h i s d o c u m e n t . O n s i t e m e a s u r e m e n t s t o b e v e r i f i e d b y t h e C o n t r a c t o r . PR O J E C T A D D R E S S : HU E Y R E S I D E N C E R E M O D E L 13 8 1 P O P P Y W A Y , CU P E R T I N O , C A 9 5 0 1 4 Design Manager: Shweta Singh PLAN CHECK REVISION106-14-24 PLAN CHECK REVISION209-20-24 BEST MGMT PRACTICES BMP R-2024-007 1/8/2025 Danielle Condit 16'-212"35'-712" (E) MULCH (E) CONCRETE MULCH MULCH MULCH (E) CONCRETE GRAVEL GRAVEL GRAVEL GRAVEL GRAVEL MULCH N89°59'29"E 100.00' N0 ° 0 0 ' 3 1 " W 60 . 0 0 ' N89°59'29"E 100.00' N0 ° 0 0 ' 3 1 " W 60 . 0 0 ' POOL SPA SI D E W A L K 30.00' 7. 3 1 ' 7. 4 0 ' 31.26' 31.24' 23.33' 23.37' 5. 7 9 ' 5. 8 6 ' 24.50' 24.60' 20.00' BSL FF 310.35 GFF 308.82 (w ) (w ) WM E ELECT METER "S" SEWER IN WALK CE N T E R L I N E PO P P Y W A Y WILD FLOWER WAY 8" PLUM LOT 112 PER 124 M 16 APN 366-18-031 LOT 113 PER 124 M 16 APN 366-18-030 FF 309.61 GAS METER CHIMNEY AC POOL EQUIP JP 5' P S E 5' W C E 2' PSE 2' PSE STREET LIGHT WM BA S I S O F B E A R I N G S N0 ° 0 0 ' 3 1 " W (E O H ) (E O H ) (E O H ) (E O H ) (E O H ) (E O H ) (EOH)(EOH)(EOH)(EOH)(EOH)(EOH)(EOH) DR I V E W A Y FA C E O F CU R B PO P P Y W A Y WOODEN FENCE EXISTING SITE PLAN SCALE: 3/16" = 1'-0" LOT AREA: 6000 SQ.FT. MINIMUM FIRST FLOOR SETBACK LINE AC FT WM GM SW-C EM FAUCET A/C EXTERNAL UNIT WATER METER SEWER CLEANOUT GAS METER ELECTRIC METER MAIN HOUSE GARAGE POOL SI D E W A L K SI D E W A L K LA N D S C A P E AC GM 6' - 0 " MI N I M U M S I D E SE T B A C K MI N I M U M S I D E SE T B A C K 20'-0" B.S.L MINIMUM FRONT SETBACK 20'-0" MINIMUM REAR SETBACK REAR SETBACK FRONT SETBACK SI D E SE T B A C K SI D E SE T B A C K CONCRETE CONCRETE MULCH SANITARY SEWER LATERAL CONNECTED TO MAIN LINE. VERIFY EXISTING LATERAL LOCATIONS IN FIELD. WM WATER LATERAL VERIFY EXISTING LATERAL LOCATION IN FIELD UP UP MAIN HOUSE ENTRY EM RAIN WATER SPOUTS /DRAIN DISCHARGE O/ SPLASHBLOCK RAIN WATER SPOUTS /DRAIN DISCHARGE O/ SPLASHBLOCK RAIN WATER SPOUTS /DRAIN DISCHARGE O/ SPLASHBLOCK RAIN WATER SPOUTS /DRAIN DISCHARGE O/ SPLASHBLOCK POOL EQUIP W.C.E SPA P. S . E P. S . E GARAGE SETBACK 31'-412"24'-812"43'-11" 7'-11" 100'-0" 28 ' - 0 12" 18 ' - 9 12" 46 ' - 1 0 " 6' - 0 12" 7' - 1 12" 60 ' - 0 " 51'-10" 9' - 0 " 19 ' - 1 " 8' - 7 " 19 ' - 2 " 46 ' - 1 0 " 5' - 1 1 " 7' - 3 " 23'-7"24'-7" 5'-0"5'-0" 2' - 0 " 2' - 0 " EASEMENT LINE LINE OF ROOF FRONT PORCH VERIFY IF THE EXISTING LATERAL IS 4 INCHES IN DIAMETER. IF IT IS NOT, THEN IT IS RECOMMENDED TO UPGRADE IT TO A 4-INCH DIAMETER. CONCRETE CONCRETE DRIVE WAY 3 TON AC 17 SEER OUTDOOR UNIT MODEL #: ML17XC1 SOUND (DBA) 73 WITH 5DB BRINMAR SOUND BLANKET 4" DIA. LEMON TREE 8" DIA. PLUM TREE P.S.E 11.02.23 Scale Drawing No. AS SHOWN Revision A l l i d e a s , d e s i g n s a n d p l a n s i n d i c a t e d o r r e p r e s e n t e d b y t h i s a r t a r e o w n e d b y a n d r e m a i n t h e p r o p e r t y u s e d o r d i s c l o s e d t o a n y o n e o f O p e n R e m o d e l . N o p a r t s h a l l b e Title Date w i t h o u t p e r m i s s i o n o f t h e C o m p a n y. No. Date RESIDENCE REMODEL Firm Name and Contact : Architecture | Home Designs www.openremodel.com contact@openremodel.com 408.357.3043 Th i s d r a w i n g h a s b e e n p r e p a r e d f o r t h e u s e o f O p e n R e m o d e l ( O R ) C l i e n t . I t m a y n o t b e u s e d , m o d i f i e d , r e p r o d u c e d , o r r e l i e d u p o n b y t h i r d p a r t i e s , e x c e p t a s a g r e e d b y O R o r a s r e q u i r e d b y l a w . O R a c c e p t s n o r e s p o n s i b i l i t y , a n d d e n i e s a n y l i a b i l i t y w h a t s o e v e r , t o a n y p a r t y t h a t u s e s o r r e l i e s o n t h i s d r a w i n g w i t h o u t O R ' s w r i t t e n c o n s e n t . D o n o t s c a l e t h i s d o c u m e n t . O n s i t e m e a s u r e m e n t s t o b e v e r i f i e d b y t h e C o n t r a c t o r . PR O J E C T A D D R E S S : HU E Y R E S I D E N C E R E M O D E L 13 8 1 P O P P Y W A Y , CU P E R T I N O , C A 9 5 0 1 4 Design Manager: Shweta Singh PLAN CHECK REVISION106-14-24 PLAN CHECK REVISION209-20-24 EXISTING SITE PLAN C1.0SURVEY SHEET FOR REFERENCE ONLY- NOT TO SCALE. R-2024-007 1/8/2025 Danielle Condit N89°59'29"E 100.00' N0 ° 0 0 ' 3 1 " W 60 . 0 0 ' N89°59'29"E 100.00' N0 ° 0 0 ' 3 1 " W 60 . 0 0 ' POOL SPA SI D E W A L K 30.00' 7. 3 1 ' 7. 4 0 ' 31.26' 31.24' 23.33' 23.37' 5. 7 9 ' 5. 8 6 ' 24.50' 24.60' 20.00' BSL FF 310.35 GFF 308.82 (w ) (w ) WM E ELECT METER "S" SEWER IN WALK CE N T E R L I N E PO P P Y W A Y WILD FLOWER WAY 8" PLUM LOT 114 PER 124 M 16 APN 366-18-029 LOT 112 PER 124 M 16 APN 366-18-031 LOT 113 PER 124 M 16 APN 366-18-030 FF 309.61 GAS METER CHIMNEY AC POOL EQUIP JP 5' P S E 5' W C E 2' PSE 2' PSE STREET LIGHT WM BA S I S O F B E A R I N G S N0 ° 0 0 ' 3 1 " W (E O H ) (E O H ) (E O H ) (E O H ) (E O H ) (E O H ) (E O H ) (EOH)(EOH)(EOH)(EOH)(EOH)(EOH)(EOH) DR I V E W A Y FA C E O F CU R B 46 ' - 1 0 " 60 ' - 0 " (N) CUPRESSUS SEMPERVIRENS ITALIAN CYPRESS PLANTED 5' APART. MIN. 15 GALLON AND 6FT PLANTED HT. (N) CUPRESSUS SEMPERVIRENS ITALIAN CYPRESS PLANTED 5' APART. MIN. 15 GALLON AND 6FT PLANTED HT. (E) POOL EQUIP (E) MULCH (E) CONCRETE (E) MULCH MULCH MULCH (E) CONCRETE (E) GRAVEL (E) GRAVEL (E) GRAVEL (E) GRAVEL (E) GRAVEL (E) MULCH (E) POOL (N) 24" BOX CERCIS OCCIDENTALIS AND 6 FEET HIGH WHEN PLANTED FRONT YARD TREE: TYPICALLY GROWS 20-40'. (N) 24" BOX LAGERSTROEMIA TUSCARORA WOODEN FENCE PROPOSED SITE PLAN SCALE: 3/16" = 1'-0" LOT AREA: 6000 SQ.FT. MINIMUM FIRST FLOOR SETBACK LINE AC FT WM GM SW-C EM FAUCET A/C EXTERNAL UNIT WATER METER SEWER CLEANOUT GAS METER ELECTRIC METER MINIMUM SECOND FLOOR SETBACK LINE EASEMENT LINE GRADING AND CONSTRUCTION HOURS AND NOISE LIMITS: a. All grading activities shall be limited to the dry season (April15 to October 1), unless permitted otherwise by the Director of Public works. b. Construction hours and noise limits shall be compliant with all requirements of Chapter 10.48 of the Cupertino Municipal Code. c. Grading, street construction, underground utility and demolition hours for work done more than 750 feet away from residential areas shall be limited to Monday through Friday, 7 a.m. to 8 p.m. and Saturday and Sunday, 9 a.m. to 6 p.m. Grading, street construction, demolition or underground utility work within 750 feet of residential areas shall not occur on Saturdays, Sundays, holidays, and during the nighttime period as defined in Section 10.48.053(b) of the Municipal Code. d. Construction activities shall be limited to Monday through Friday, 7 a.m. to 8 p.m. and Saturday and Sunday, 9 a.m. to 6 p.m. Construction activities are not allowed on holidays as defined in Chapter 10.48 of the Municipal Code. Night time construction is allowed if compliant with nighttime standards of Section 10.48 of the Cupertino Municipal Code. e. Rules and regulations pertaining to all construction activities and limitations identified in this permit, along with the name and telephone number of an applicant appointed disturbance coordinator, shall be posted in a prominent location at the entrance to the job site. f. The applicant shall be responsible for educating all contractors and subcontractors of said construction restrictions. The applicant shall comply with the above grading and construction hours and noise limit requirements unless otherwise indicated PO P P Y W A Y (E) MAIN HOUSE SI D E W A L K SI D E W A L K LA N D S C A P E (E) AC GM 20'-0" B.S.L MINIMUM FRONT FIRST FLOOR SETBACK 20'-0" MINIMUM FIRST FLOOR REAR SETBACK FRONT SETBACK (E) CONCRETE DRIVE WAY CONCRETE CONCRETE MULCH (E) MULCH WM W.C.EP.S.E SPA P. S . E P. S . E GARAGE SETBACK 31'-412"24'-812"43'-11" 7'-11" 100'-0" 28 ' - 0 12" 18 ' - 9 12" 6' - 0 12" 7' - 1 12" 5'-0"5'-0" 2' - 0 " 2' - 0 " UP MAIN HOUSE ENTRY EM UP (N) LANDING (N) EXTENDED AREA = 94 SF PROPOSED SECOND FLOOR = 647 SQ.FT. 10 ' - 0 " 25'-0" 25'-0" MI N I M U M S E C O N D FL O O R S I D E SE T B A C K A S P E R CI T Y D I S C U S S I O N MINIMUM SECOND FLOOR REAR SETBACK MINIMUM SECOND FLOOR FRONT SETBACK 25'-2" SECOND FLOOR FRONT SETBACK 27'-3" SECOND FLOOR REAR SETBACK 10 ' - 0 " S E C O N D F L O O R SI D E S E T B A C K 5% DRAINAGE AROUND/ AWAY FROM THE BUILDING FOR A MIN. DISTANCE OF 10'-0"SHALL NOT DRAIN ON TO OTHER PARCELS PER SECTIONS R300.2, R401.3 CRC, 4.106 CGBC AND 1101.2 CPC. FI R S T F L O O R SI D E S E T B A C K LINE OF FIRST FLOOR ROOF LINE OF SECOND FLOOR LINE OF SECOND FLOOR ROOF 6' - 0 " REAR SETBACK FI R S T F L O O R SI D E S E T B A C K 16'-212"35'-712" 51'-10" 9' - 0 " 19 ' - 1 " 19 ' - 2 " 5' - 1 1 " 7' - 3 " 15 ' - 0 " MI N I M U M S E C O N D FL O O R S I D E SE T B A C K MI N I M U M F I R S T FL O O R S I D E SE T B A C K MI N I M U M F I R S T FL O O R S I D E SE T B A C K (E) RAIN WATER SPOUTS /DRAIN DISCHARGE O/ SPLASHBLOCK (E) RAIN WATER SPOUTS /DRAIN DISCHARGE O/ SPLASHBLOCK (E) RAIN WATER SPOUTS /DRAIN DISCHARGE O/ SPLASHBLOCK (N) RAIN WATER SPOUTS /DRAIN DISCHARGE O/ SPLASHBLOCK (N) RAIN WATER SPOUTS /DRAIN DISCHARGE O/ SPLASHBLOCK 24'-7" DIRECTION OF DRAINAGE FRONT PORCH SANITARY SEWER LATERAL CONNECTED TO MAIN LINE. VERIFY EXISTING LATERAL LOCATIONS IN FIELD. WATER LATERAL VERIFY EXISTING LATERAL LOCATION IN FIELD VERIFY IF THE EXISTING LATERAL IS 4 INCHES IN DIAMETER. IF IT IS NOT, THEN IT IS RECOMMENDED TO UPGRADE IT TO A 4-INCH DIAMETER. LINE OF DEMOLITION CHIMNEY (E) GARAGE 34 ' - 1 0 " S E C O N D F L O O R SI D E S E T B A C K (E) 4" DIA. LEMON TREE (N ) A C (N) CONCEALED DUCTED MINI SPLIT AIR CONDITIONING AND HEAT PUMP DAIKIN FDMQ 12K BTU OUTDOOR UNIT MODEL #: RX12RMVJUA INDOOR UNIT MODEL #: FDMQ12RVJU SOUND (DBA) 51 (E) 3 TON AC RELOCATED 17 SEER OUTDOOR UNIT MODEL #: ML17XC1 SOUND (DBA) 73 WITH 5DBA BRINMAR SOUND BLANKET FUTURE GARAGE EXPANSION TO MIN. CLEAR AREA, IN FUTURE, IF REQUIRED 8' - 7 " 46 ' - 1 0 " (E) 8" DIA. PLUM TREE 18 ' - 4 " PL T O A C S E T B A C K 21 ' - 1 0 " PL T O A C S E T B A C K 1 1 1 GFCI WP 220V GFCI WP 220V DUST CONTROL: The following construction practices shall be implemented during all phases of construction for the proposed project to prevent visible dust emissions from leaving the site: a) Water all exposed surfaces areas (e.g., parking areas, staging areas, soil piles, graded areas, and unpaved access roads) at least twice daily and more often during windy periods to prevent visible dust from leaving the site; active areas adjacent to windy periods; active areas adjacent to existing land uses shall be kept damp at all times, or shall be treated with non-toxic stabilizers or dust palliatives. b) All haul trucks transporting soil, sand, or other loose material off-site shall be covered. c) All visible mud or dirt track-out onto adjacent public roads shall be removed using wet power vacuum street sweepers at least once per day. The use of dry power sweeping is prohibited. d) All vehicle speeds on unpaved roads shall be limited to 15mph. e) All roadways, driveways, and sidewalks to be paved shall be completed as soon as possible. Building pads shall be laid as soon as possible after grading unless seeding or soil binders are used. f) Idling times shall be minimized either by shutting equipment off when not in use or reducing the maximum idling time to 5 minutes (as required by the California airborne toxics control measure Title 13, Section 2485 of California Code of Regulations [CCR]). Clear signage shall be provided for construction workers at all access points. g) All construction equipment shall be maintained and properly tuned in accordance with manufacturer's specifications. All equipment shall be checked by a certified mechanic and determined to be running in proper condition prior to operation. h) Post a publicly visible sign with the telephone number and person to contact at the Lead Agency regarding dust complaints. This person shall respond and take corrective action within 48 hours. The Air District's phone number shall also be visible to ensure compliance with applicable regulations. i) The applicant shall incorporate the City's construction best management practices into the building permit plan set.EROSION CONTROL NOTES: ·ALL EROSION CONTROL MEASURES SHALL BE ONSITE AND READILY ACCESSIBLE PRIOR TO CONSTRUCTION. ·SWEEP OR SCRAPE UP SOILS TRACKED ONTO THE ROAD AT THE END OF EACH DAY. DO NOT HOSE INTO STREET, GUTTER, OR STORM. ·REVEGETATE DISTURBED AREAS. EXPOSED BARE DIRT SHALL BE COVERED WITH MULCH, JUT NETTING OR OTHER EROSION CONTROL BLANKET. ·ALL TEMPORARY STOCKPILES SHALL BE COVERED WITH 6MIL PLASTIC SHEETS, SUITABLY ANCHORED. THE SITE SHALL BE MONITORED BY THE CONTRACTOR/OWNER AFTER RAIN EVENT TO VERIFY EROSION CONTROL MEASURES ARE FUNCTIONING. PROTECT (E) CATCH BASIN WITH GRAVEL BAGS. LINE OF PRIVACY VIEWSHEDS 3 0 . 0 ° 30 . 0 ° 30 . 0 ° 3 0 . 0 ° 3 0 . 0 ° 30.0°30.0° LINE O F P R I V A C Y V I E W S H E D S LI N E O F P R I V A C Y V I E W S H E D S L I N E O F P R I V A C Y V I E W S H E D S ALL EXTERIOR LIGHT FIXTURES TO BE FULLY SHIELDED WITH ZERO UPLIGHT LA N D S C A P E 1 1 1 1 1 2 2 REDUCE FRONT YARD WOOD FENCE HEIGHT TO 3' MAX 23'-7" 2 2 2 REDUCE FRONT YARD WOOD FENCE HEIGHT TO 3' MAX 2 11.02.23 Scale Drawing No. AS SHOWN Revision A l l i d e a s , d e s i g n s a n d p l a n s i n d i c a t e d o r r e p r e s e n t e d b y t h i s a r t a r e o w n e d b y a n d r e m a i n t h e p r o p e r t y u s e d o r d i s c l o s e d t o a n y o n e o f O p e n R e m o d e l . N o p a r t s h a l l b e Title Date w i t h o u t p e r m i s s i o n o f t h e C o m p a n y. No. Date RESIDENCE REMODEL Firm Name and Contact : Architecture | Home Designs www.openremodel.com contact@openremodel.com 408.357.3043 Th i s d r a w i n g h a s b e e n p r e p a r e d f o r t h e u s e o f O p e n R e m o d e l ( O R ) C l i e n t . I t m a y n o t b e u s e d , m o d i f i e d , r e p r o d u c e d , o r r e l i e d u p o n b y t h i r d p a r t i e s , e x c e p t a s a g r e e d b y O R o r a s r e q u i r e d b y l a w . O R a c c e p t s n o r e s p o n s i b i l i t y , a n d d e n i e s a n y l i a b i l i t y w h a t s o e v e r , t o a n y p a r t y t h a t u s e s o r r e l i e s o n t h i s d r a w i n g w i t h o u t O R ' s w r i t t e n c o n s e n t . D o n o t s c a l e t h i s d o c u m e n t . O n s i t e m e a s u r e m e n t s t o b e v e r i f i e d b y t h e C o n t r a c t o r . PR O J E C T A D D R E S S : HU E Y R E S I D E N C E R E M O D E L 13 8 1 P O P P Y W A Y , CU P E R T I N O , C A 9 5 0 1 4 Design Manager: Shweta Singh PLAN CHECK REVISION106-14-24 PLAN CHECK REVISION209-20-24 PROPOSED SITE PLAN C2.0 R-2024-007 1/8/2025 Danielle Condit 11.02.23 Scale Drawing No. AS SHOWN Revision A l l i d e a s , d e s i g n s a n d p l a n s i n d i c a t e d o r r e p r e s e n t e d b y t h i s a r t a r e o w n e d b y a n d r e m a i n t h e p r o p e r t y u s e d o r d i s c l o s e d t o a n y o n e o f O p e n R e m o d e l . N o p a r t s h a l l b e Title Date w i t h o u t p e r m i s s i o n o f t h e C o m p a n y. No. Date RESIDENCE REMODEL Firm Name and Contact : Architecture | Home Designs www.openremodel.com contact@openremodel.com 408.357.3043 Th i s d r a w i n g h a s b e e n p r e p a r e d f o r t h e u s e o f O p e n R e m o d e l ( O R ) C l i e n t . I t m a y n o t b e u s e d , m o d i f i e d , r e p r o d u c e d , o r r e l i e d u p o n b y t h i r d p a r t i e s , e x c e p t a s a g r e e d b y O R o r a s r e q u i r e d b y l a w . O R a c c e p t s n o r e s p o n s i b i l i t y , a n d d e n i e s a n y l i a b i l i t y w h a t s o e v e r , t o a n y p a r t y t h a t u s e s o r r e l i e s o n t h i s d r a w i n g w i t h o u t O R ' s w r i t t e n c o n s e n t . D o n o t s c a l e t h i s d o c u m e n t . O n s i t e m e a s u r e m e n t s t o b e v e r i f i e d b y t h e C o n t r a c t o r . PR O J E C T A D D R E S S : HU E Y R E S I D E N C E R E M O D E L 13 8 1 P O P P Y W A Y , CU P E R T I N O , C A 9 5 0 1 4 Design Manager: Shweta Singh PLAN CHECK REVISION106-14-24 PLAN CHECK REVISION209-20-24 CALGREEN REQUIREMENTS CAL CALGREEN REQUIREMENTS: 0- RECYCLE AND/OR SALVAGE FOR REUSE A MIN OF 65% OF THE NON-HAZARDOUS CONSTRUCTION AND DEMOLITION WASTE IN ACCORDANCE WITH ONE OF THE FOLLOWING: a) COMPLY WITH A MORE STRINGENT LOCAL CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT ORDINANCE; OR b) A CONSTRUCTION WASTE MANAGEMENT PLAN, PER SEC. 4.408.2; OR c) A WASTE MANAGEMENT COMPANY, PER SEC. 4.408.3; OR d) THE WASTE STREAM REDUCTION ALTERNATIVE, PER SEC 4.408.4 1- ADHESIVES, SEALANTS AND CAULKS SHALL BE COMPLIANT WITH VOC AND OTHER TOXIC COMPOUND LIMITS. 2- PAINTS, STAINS AND OTHER COATINGS SHALL BE COMPLIANT WITH VOC LIMITS. 3- AEROSOL PAINTS AND COATINGS SHALL BE COMPLIANT WITH PRODUCT WEIGHTED MIR LIMITS FOR ROC AND OTHER TOXIC COMPOUNDS. 4- DOCUMENTATION SHALL BE PROVIDED TO VERIFY THAT COMPLIANT VOC LIMIT FINISH MATERIALS HAVE BEEN USED. 5- CARPET AND CARPET SYSTEMS SHALL BE COMPLIANT WITH VOC LIMITS. 6- MOISTURE CONTENT OF BUILDING MATERIALS USED IN WALLS AND FLOOR FRAMING IS CHECKED BEFORE CLOSURE. 7- PLUMBING FIXTURES AND FITTINGS REQUIRED IN SEC. 4.303.1 SHALL BE INSTALLED IN ACCORDANCE WITH CPC AND SHALL MEET THE APPLICABLE REFERENCED STANDARDS. 8- BUILDER/CONTRACTOR SHALL SUBMIT DOCUMENTATION TO THE BUILDING INSPECTOR SHOWING THAT THE INSTALLED PLUMBING FIXTURES MEET THE MAXIMUM ALLOWABLE FLOW RATES AS NOTED BELOW: WATER CLOSET - 1.28 GPM SHOWER HEADS - 1.8 GPM AT 80 PSI KITCHEN FAUCETS - 1.8 GPM AT 60 PSI LAVATORY FAUCETS - 1.2 GPM AT 60 PSI & MIN 0.8 GPM AT 20 PSI 9- ANNULAR SPACES AROUND PIPES, ELECTRIC CABLES, CONDUITS OR OTHER OPENINGS IN SOLE/BOTTOM PLATES AT EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, CONCRETE MASONRY OR SIMILAR METHOD ACCEPTABLE TO THE ENFORCING AGENCY. 10- DUCT OPENINGS AND OTHER RELATED AIR DISTRIBUTION COMPONENTS SHALL BE COVERED DURING CONSTRUCTION. 11- 80% OF FLOOR AREA RECEIVING RESILIENT FLOORING SHALL COMPLY WITH VOC-EMISSION LIMITS DEFINED BY CHPS 12-PARTTICLEBOARD, MEDIUM DENSITY FIBERBOARD (MDF) AND HARDWOOD USED IN INTERIOR FINISH SYSTEMS SHALL COMPLY WITH LOW FORMALDEHYDE EMISSION STANDARDS. 13- INSTALL ONLY DIRECT VENT SEALED-COMBUSTION GAS OR SEALED WOOD-BURNING FIREPLACES, OR A SEALED WOODSTOVE. 14- VAPOR RETARDERS AND CAPILLARY BRAKE IS INSTALLED IN SLAB ON GRADE FOUNDATION 15- OPERATIONAL MANUALS SHOULD BE PROVIDED TO THE OWNER OR BUILDING OCCUPANTS 16. BATHROOM FAN MUST BE ENERGY STAR COMPLIANT. UNLESS FUNCTIONING AS A WHOLE HOUSE VENTILATION SYSTEM, FANS MUST BE CONTROLLED BY A HUMIDITY CONTROL - HUMIDITY CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE LESS THAN OR EQUAL TO 50% TO A MAX OF 80%. A HUMIDITY CONTROL MAY UTILIZE MANUAL OR AUTOMATIC MEANS OF ADJUSTMENT - A HUMIDITY CONTROL MAY BE A SEPARATE COMPONENT TO THE EXHAUST FAN AND IS NOT REQUIRED TO BE INTEGRAL(BUILT-IN). R-2024-007 1/8/2025 Danielle Condit 11.02.23 Scale Drawing No. AS SHOWN Revision A l l i d e a s , d e s i g n s a n d p l a n s i n d i c a t e d o r r e p r e s e n t e d b y t h i s a r t a r e o w n e d b y a n d r e m a i n t h e p r o p e r t y u s e d o r d i s c l o s e d t o a n y o n e o f O p e n R e m o d e l . N o p a r t s h a l l b e Title Date w i t h o u t p e r m i s s i o n o f t h e C o m p a n y. No. Date RESIDENCE REMODEL Firm Name and Contact : Architecture | Home Designs www.openremodel.com contact@openremodel.com 408.357.3043 Th i s d r a w i n g h a s b e e n p r e p a r e d f o r t h e u s e o f O p e n R e m o d e l ( O R ) C l i e n t . I t m a y n o t b e u s e d , m o d i f i e d , r e p r o d u c e d , o r r e l i e d u p o n b y t h i r d p a r t i e s , e x c e p t a s a g r e e d b y O R o r a s r e q u i r e d b y l a w . O R a c c e p t s n o r e s p o n s i b i l i t y , a n d d e n i e s a n y l i a b i l i t y w h a t s o e v e r , t o a n y p a r t y t h a t u s e s o r r e l i e s o n t h i s d r a w i n g w i t h o u t O R ' s w r i t t e n c o n s e n t . D o n o t s c a l e t h i s d o c u m e n t . O n s i t e m e a s u r e m e n t s t o b e v e r i f i e d b y t h e C o n t r a c t o r . PR O J E C T A D D R E S S : HU E Y R E S I D E N C E R E M O D E L 13 8 1 P O P P Y W A Y , CU P E R T I N O , C A 9 5 0 1 4 Design Manager: Shweta Singh PLAN CHECK REVISION106-14-24 PLAN CHECK REVISION209-20-24 CALGREEN CHECKLIST CG R-2024-007 1/8/2025 Danielle Condit