Loading...
A0.3_PROPOSED SITE PLANWUNDERLICH DRIVE ( 60' R/W ) S.52°15'00"E. 55.00' N. 3 7 ° 4 5 ' 0 0 " E . 1 3 5 . 1 6 ' S.68°00 ' 0 0 " E . 5 7 . 1 5 ' 5' P.U.E. N. 3 7 ° 4 5 ' 0 0 " E . 1 1 9 . 6 5 ' P.L. P.L. P. L . P. L . TBM JP GM (E) WINDOW AT 2ND FLOOR (TYP.) x x x x x x x x x x x x x x x x x x x x (E) WINDOW AT 2ND FLOOR (TYP.) (E) WINDOW AT 2ND FLOOR (TYP.) EL=100.00 MH SSCO O / H E L E C 6" G R O V E O F T R E E S 9" - 1 1 " G R O V E O F T R E E S 4"TREE 4"ORANGE 4"ORANGE 4"ORANGE 14"TREE 10741 WUNDERLICH DRIVE PROPOSED HOUSE 10731 WUNDERLICH DRIVE EXISTING HOUSE 10751 WUNDERLICH DRIVE EXISTING HOUSE (E) WINDOW AT 2ND FLOOR (TYP.) (N) 400 EMP (E) CONC. PAVEMENT (E) CONC. PAVEMENT 36 ' - 6 " 49 ' - 2 " 6'-0" 5' MIN. 1ST FL SETBACK COMBINED 15' 14'-9" 5' MIN. 1ST FL SETBACK COMBINED 15' 12'-6" 5'-0" 24 ' - 0 " (N) LANDSCAPE 20'-0" (N) PAVER DRIVEWAY. REFER TO 3/A0.2 10'x20'10'x20' 12'-6" 12'-6" MIN. SETBACK 12'-6" MIN. SETBACK 47 ' - 2 " 33 ' - 8 " 25 ' - 0 " M I N . S E T B A C K 20 ' - 0 " M I N . S E T B A C K 20 ' - 0 " M I N . S E T B A C K 25 ' - 0 " M I N . S E T B A C K (N) CONC. PATIO 22 ' - 0 " 20 ' - 0 " M I N . SE T B A C K ADU 1ST FLOOR 2ND FLOOR 1,859 SF 1,223 SF 797 SF WP WP WPWPWP WP WP (N) CONC. LANDING WP (N ) P A V E R WA L K W A Y (N ) C O N C . WA L K W A Y (N ) C O N C . WA L K W A Y (N) PAVER WALKWAY (N) MULCH (N) PRIVACY SCREEN TREE, TYP. SEE LANDSCAPE PLAN (N) PROPOSED TREE. SEE LANDSCAPE PLAN 1 102 . 9 8 2 N 101 . 4 9 3 TP 102 . 5 6 20 2122 23 24 32 33 34 35 36 37 38 39 40 GFC 103 . 7 8 41 GFC 103 . 0 4 43 GFC 102 . 5 3 44 GFC 103 . 3 6 46 GFC 102 . 7 6 47 GFC 102 . 7 2 48 GFC 102 . 6 8 49 GFC 102 . 7 2 52 102 . 7 0 53 102 . 8 1 54 102 . 6 5 55 102 . 7 2 56 102 . 6 7 57 58 102 . 5 6 59 102 . 8 6 60 103 . 0 8 61 62 102 . 9 6 63 64 103 . 0 2 65 103 . 1 2 66 103 . 2 0 67 103 . 2 6 68 103 . 0 2 69 102 . 7 3 70 102 . 8 0 71 102 . 8 5 72 G 102 . 5 4 73 G 102 . 6 5 74 G 103 . 0 5 75 G 102 . 7 2 76G 103 . 0 0 77 G 102 . 6 8 78 G 102 . 8 7 79 G 102 . 6 6 80 102 . 7 481 102 . 6 6 82 102 . 5 7 83 G 102 . 5 6 84 G 102 . 5 3 85 TP 102 . 6 5 86 102 . 6 9 87 102 . 6 5 92 93 94 95 96 98 GFC102 . 9 1 100 FC 101 GFC 102 . 9 3 102 GFC 102 . 8 6 103 GFC 102 . 9 4 104 GFC 102.96 105GFC 102 . 6 1 108G 102 . 8 3 109 G 102 . 6 7 110G 102 . 7 4 111 112 114 FF 103 . 3 0 115 116 102 . 7 3 117 102 . 6 5 118 TP 102 . 6 0 119 120 121 EC 102 . 5 8 122 EC 102 . 6 5 123 EC 102 . 3 3 124 EC 101 . 9 7 125 EC 101 . 0 7 126 127 130 132 133 134 135 136 137 138 FG 102 . 4 8 139 TP 101 . 2 1 141 142 143 144 147 150 EC 101 . 2 5 151 102 . 4 0 152 102 . 3 4 154G 101 . 0 4 155 G 102 . 7 9 156 G 102 . 5 6 157 G 102 . 6 6 158 G102 . 4 0 159 G 101 . 9 0 160 G 101 . 0 5 161 G101 . 2 5 173 213 FCO R 214 215 TP 102 . 5 7 216 (N) CONDENSER 16'-6" WP SCALE: 3/32" = 1'-0" PROPOSED SITE PLAN Sheet Date Check Scale Drawn Revisions By Noted 1 A0.3 NORTH L.L. Designer Linda Lin 6525 Crown Blvd. #41068 San Jose, CA 95160 lindal.designstudio@gmail.com Project Name PROPOSED SITE PLAN Drawing Name FRONT YARD AREA: 1,339 SQ.FT. FRONT YARD IMPERVIOUS AREA: 639 SQ.FT. FRONT YARD IMPERVIOUS AREA RATIO: 48% (N) HIGH EFFICACY EXTERIOR WATER PROOF WALL MOUNTED LIGHT FIXTURE. BEL AIR LIGHTING, "CALI" 1-LIGHT SMALL BRONZE CYLINDER OUTDOOR WALL LIGHT SCONCE (FIXTURE IS OPEN AT THE BOTTOM), OR SIMILAR. HT.: 7.3". CONSTRUCTED OF WEATHER RESISTANT IRON. WATTAGE: LED 60 WATTS EQUIVALENT. COLOR TEMPERATURE OF 3,000 KELVIN OR LESS. CONTROLLED BY A MANUAL ON AND OFF SWITCH WITH PHOTOCELL AND EITHER A MOTION SENSOR OR AN AUTOMATIC TIME SWITCH CONTROL; OR CONTROLLED BY AN ASTRONOMICAL TIME CLOCK CONTROL PER CENC §150.0 (K) (3) (A). REFER TO 3 & 4 / A0.3 FOR DETAILS. WP A0.3 SCALE: N.T.S. CITY STANDARD DRIVEWAY DETAIL 4 A0.3 1. ALL FENCES ARE EXISTING STANDARD 6' HT. RESIDENTIAL FENCES. NO PROPOSED FENCES. 2. TREES TO BE REMOVED AND REPLACED ARE NOTED ON PLANS. 3. A MINIMUM 5% GRADE SLOPE AWAY FROM FOUNDATION FOR A MINIMUM DISTANCE OF 10 FEET MEASURED PERPENDICULAR TO THE FACE OF THE WALL. (R401.3) EXCEPTIONS: A) IF BUILDING SITE DOES NOT ALLOW 10 FEET OF SLOPE, INSTALL DRAINS OR SWALES TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. B) IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2% AWAY FROM THE BUILDING. 4. EXISTING AND PROPOSED DOWNSPOUTS FROM THE ROOF ARE INDICATED ON 1/A0. INSTALL SPLASH BLOCKS AT ALL DOWNSPOUTS TO ENSURE ROOF WATER IS DIRECTED AWAY FROM THE FOUNDATION. ANY EXISTING DOWNSPOUTS THAT CONNECT DIRECTLY TO THE STORM DRAIN SYSTEM SHALL BE DISCONNECTED AND DIRECTED TOWARDS LANDSCAPED AREAS. 5. IF THE PROJECT DAMAGES THE CITY’S SIDEWALK, DRIVEWAY, OR CURB AND GUTTER AS RESULT OF CONSTRUCTION ACTIVITIES, THE PROPERTY OWNER WILL BE RESPONSIBLE TO REMOVE AND REPLACE ANY BROKEN CONCRETE (EXISTING OR DAMAGES BY THE PROJECT) AS DIRECTED BY THE PUBLIC WORKS INSPECTOR. AN ENCROACHMENT PERMIT WILL ALSO BE REQUIRED. 6. THE USE OF COPPER METAL ROOFING, COPPER GRANULE CONTAINING ASPHALT SHINGLES, COPPER GUTTERS AND DOWNSPOUTS, AND/OR OTHER EXTERIOR ORNAMENTAL COPPER IS STRONGLY DISCOURAGED FOR ALL RESIDENTIAL BUILDING PROJECTS. 7. WHERE POSSIBLE, DIRECT STORM DRAINAGE FROM REAR OF PROPERTY THROUGH GRASS SWALES TO THE PUBLIC RIGHT OF WAY. 8. NO NEW LANDSCAPE IS PROPOSED EXCEPT REMOVING (E) DRIVEWAY AND COVER THE AREA WITH MULCH. 9. THE PROJECT IS SUBJECT TO THE STANDARDS AND REQUIREMENTS OF CITY CODE CHAPTER 17.04. THESE STANDARDS INCLUDE MEASURES TO PROTECT NESTING BIRDS SHOULD CONSTRUCTION TAKE PLACE BETWEEN FEBRUARY 1 AND AUGUST 31. PROJECT CONSTRUCTION ACTIVITIES WILL CONFORM TO THE APPLICABLE REQUIREMENTS OF CITY CODE CHAPTER 17.04. 10. PER CITY CODE SECTION 14.18.210, THE CITY'S STANDARD TREE PROTECTION MEASURES, OUTLINED IN APPENDIX A OF CITY CODE CHAPTER 14.18, AN ISA-CERTIFIED ARBORIST WILL BE REQUIRED TO VERIFY THE HEALTH OF THE TREE AND THAT THE TREE PROTECTION MEASURES ARE IN PLACE PRIOR TO CONSTRUCTION. THE ARBORIST WILL ALSO NEED TO VERIFY THE HEALTH OF THE TREE FOLLOWING CONSTRUCTION. SHEET NOTES 10 7 4 1 W U N D E R L I N C H D R I V E CU P E R T I N O , C A 9 5 0 1 4 ZH U R E S I D E N C E NE W H O U S E + A D U 01/21/24 1 1 05/14/241 L.L. 1 1 EXTERIOR WALL SCONCE DETAILS SCALE: NONE 3 A0.3 LIGHT BULB SPECIFCATIONS FOR EXTERIOR WALL SCONCE SCALE: NONE 1 2 A0.3 1 OUTDOOR LIGHTING SHALL COMPLY WITH THE OUTDOOR LIGHTING REQUIREMENTS 19.102.040 I. OUTDOOR LIGHTING MUST BE FULLY SHIELDED FIXTURES, DIRECTED DOWNWARD TO MEET PARTICULAR NEED AWAY FROM ADJACENT PROPERTIES AND RIGHTS-OF-WAYS TO AVOID LIGHT TRESPASS. II. ALL LIGHT SOURCES SHALL HAVE A MAINTAINED CORRELATED COLOR TEMPERATURE OF 3,000 KELVIN OR LESS. III. ALL OUTDOOR LIGHTING MUST BE FULLY EXTINGUISHED OR BE MOTION SENSOR OPERATED BY 11:00 P.M. OR WHEN PEOPLE ARE NO LONGER PRESENT IN EXTERIOR AREAS, WITH EXCEPTIONS. IV. LIGHTING DESIGN STANDARDS SUCH AS LIGHTING FIXTURES MUST BE OF A DESIGN THAT COMPLEMENTS THE BUILDING AND LANDSCAPE DESIGN. V. PROHIBITED LIGHTING INCLUDES OUTDOOR BLINKING, FLASHING, OR ROTATING LIGHTS, FLOOD LIGHTS, SPOTLIGHTS, AND OTHERS AS APPLICABLE. OUTDOOR LIGHTING REQUIREMENTS: 1 09/04/242 L.L. 2 2