Loading...
DIR-1998-03b CITY OF CUPERTINO":brD _ oq~ _ =========================================================~~LJ==-O~' 10300 Torre Avenue, Cupertino, California 95014 (408) 777-3308 To: Mayor and City Councilmembers Chair and Planning Commission From: Robert S. Cowan, Director of Community Development RS<:- Date: March 10, 1998 Subj: Minor Modification of 26-U-86 to allow change of fascia on an existing gasoline station canopy at 21855 Homestead Road Chapter 19.132 of the Cupertino Municipal Code allows for administrative approval of minor changes to a project. The Director reports his decision to the City Council and Planning Commission in time to allow any Councilmember or Planning Commissioner to appeal the decision within fourteen calendar days. Application: Minor Modification of 26-U-86 to allow change of fascia and columns on an existing gasoline station canopy at 21855 Homestead Road Description: The applicant, Bruce Turner, representing Tosco Marketing Company, is proposing changes to the fascia and column shrouds for the BP gasoline station canopy at the above captioned address. The fascia and column shroud changes usually signifies a change in the gasoline supplier, in this case, probably Union 76. The proposal is to replace the green, bullnose (rounded) composite aluminum fascia with an eggshell white, flat composite aluminum fascia panel. There will be a minor narrowing of the fascia panel and no overall change in the height or size of the canopy. The grey column shrouds will be replaced by eggshell white-colored shrouds. New signage will be separately permitted. Staff does not expect a time period when the canopy will be white and the ground sign will be "BP" green and yellow. Oil companies are concerned with maintaining a clear corporate identity for their customers, and staff fully expects the chang over in the canopy and signage to occur at the same time even if they are permitted at different times. Action: The Director of Community Development deems the modification minor and approves the change in the canopy fascia and column shrouds per the 3 sheet plan set, titled "4- Column Canopy "76" Image Modification". This approval of the modification is effective March 10, 1998. The fourteen calendar day appeal period will expire on March 24, 1998. H:worddo/tosco 1 2 i f i .,; ~ ~ j '" ~ 1 i TO LOCAL BUILDING DEPARTMENT BUILDING OFFICIALS and PLAN CHECK EXAMINERS Madison Industries, a division of John S. Frey Enterprises, has been a fabricator and erector of pre-engineered steel and sheet metal buildings since 1947, specializing in service station facilities. t.tadison Industries specialization, in addition to the remodeling of existing steel/sheet metal structures, includes the fabrication and erection of canopies and a variety of prefabricated modular structures including car-wash buildings, food marts, offices, storages, restrooms, and fast food restaurants. t.tadison Industries is lacated in Los Angeles County 0 1900 East 64TH. Street, Los Angeles, Co 90001 Phone (213) 583-4061 Fax (213) 582-1015 i UCENSES AND CERTIFICATION: State Contractor License No. 119949-G43 and C51 (Steel and sheet metal). State Contractor License No. 287826-B (General). Stale Commercial Coach Manufacturer Ucense NO. 9<JO.48. Los Angeles L.icense Fabricator No. 102. Chief Engineer and Structural Oesigner: Robert E. Hansen C.E. 11372 Workmen's Cannpensation: CNA Insurance (assi<)ned to Transportation Insurance Co.) Policy No. 5823848 ~ '" I BUIUDlNG CODE ClASSIFICATION: OCCUPANCY ClASSIFICATION (as per 1994 use - Table 3.6.): PUMP-ISlAND CANOPY CONSTRUCTION lYPE: Group S Oi.. 3 Type II - N DESIGN CRITERIA: ROOF lNE LOAD: ROOF IlEAll LOAD: WINO LOAD: SEISMIC OESIGN: SEE STRUCTURAL CALCULATIONS SEE STRUCTURAL CALCULATIONS SEE STRUCTURAL CALCULATIONS SEE STRUCTURAL CALCULATIONS FABRICATION: 1 - Fabrication methods and workmanship shall conform to the requirements of the 1994 Edition of the Uniform Building Code and the A.I.S.C. Manual of Steel Construction (A.S.O.) Ninth Edition. 2 - Fabrication shall be performed in t.tadisan's licensed Los Angeles plant in accordance with approved shop drawings. WELDING: STRUCTURAL STEEL WELDING: 1 - Structural welding shall be by the electric arc process and conform to AWS 01.1-96. 2 - Structural welding shall be performed by 0 certified welder at MacflSQll Industries Los Angeles approved fabricator shop. 3 - All structural foeld welding (if any) shall be done by a licensed certified welder under the direction of a licensed welding inspector. (Must be approved by Iacal jurisdiction) 4 - AWS E70XX electrodes shall be used for structural welds. LIGHT GAUGE STEEL WELDING: 1 - Ught gouge structural welding sholl conform to AWS 01.3-96 2 - Ught gouge structural welding sholl be performed by 0 certified welder at t.tadison Industries Los Angeles approved fabricator shop. 3 - AWS E70XX electrodes or inert gas shielded arc sholl be used far light gouge structural welds. STEEL: STRUCTURAL STEEL: 1 - Structural steel shapes shall conform to U.B.C. Chapter 22 and ASTt.t A-36 2 - Square and rectangular structural steel tubing sholl conform lo ASTt.t A-5OO, grade B. 3 - Structural steel pipe shall conform to ASTt.t A-53, grade B. 4 - Structural steel design shan be done in accordance with the requirements of the Uniform Building Code and the I>ISI:. t.tanual of Steel Construction, Ninth Edition. 5 - Structural steel fabrication sholl be done in accordance with the I>ISI:. Code of Slondard Practice for Steel Buadings and Bridges. LIGHT GAUGE STEEL: 1 - Ught gouge structural steel shal conform to ASTt.t A-446, grade B or 0 as designated on the shop drawings or colculations. 2 - Ught gouge square and rectangular structural steel tubing shall conform to ASTt.t A-513, grode t,tT-l01O. 3 - Oesi<)n and fabrication of ~ght gouge formed structurol steel sholl be done in accardonce with the A1SI Cold Formed Steel Design Manual. FORMED SHEET METAL ROOF AND WALL PANELS: 1 - Ught gouge sheet steel used for roof deck and wall ponels sholl conform lo ASTt.t A-446, grode O. 2 - Roof deck and wall ponels shall be continuously rolled farmed or lacked formed on a press broke. FASTENERS: 1 - All bolts shall be A-3D7 unless noted otherwise. (No speciol inspection required) 2 - Sheet metal screws sholl be of 0 type as Approved in I.c.B.a. report 13056 and or LA Research report RR 24029, RR 23768, or RR 23971 CONCRETE: FOOTING DESIGN: 1 - Footing designs ore based on on assumed bearing value of 1000 p.s.f. at one foot depth, with 0 20X increase per foot of depth (to a maximum of 3,000 p.s.f.). Passive lateral pressure - 200 p.s.f.(assumed). 2 - Bottoms of all bearing footings ore to be 12' minimum belaw top of undisturtoed notural sailor 90% compacted fill. 3 - Concrete used for foundations and footings sholl be mochine mixed with 0 compressive strength of 2,500 p.s.i. minimum. (NO SPECIAl. INSPECTION REQUIRED) 4 - Reinforcing steel for footings (if required by desi<)n) shaH be de-formed bars conforming to ASTt.t A-615, grade 40 or 60. Lop re-bars minimum 3D diameters unless noted otherwise. 5 - Dry-Pack sholl be oroe port cement and three ports sand. Mixed as dry as possible. 6 - All materials and workmanship shall conform to A.C.I. - 318. (SpeciflCOtians for the Oesi<)n and Placement of Concrete). 7 - NOlE: No steel work sholl be set or erected on the footings until the concrete hos cured for a minimum of three (3) days. PERMIT PLANS: FlElQJNSPECTlONS: The projects presented on t.tacflSOn Industries permit plans reflect and apply only to the previoosly indicated types of steel/sheet metal structures A typical project may consist of complete new structures, remodel of existing structures or 0 combinotion of the two. Unless speciflCOlly required by the local jurisdiction's building offICial or specifted on permit plans, fteld special inspection(s) is/ore not required as per below listed reosan(s): 1 - Type of work by llodison Industries as shown on permit plans is not fisted under 1994 U.B.C. section 1701.5 (Special InspectiOns) 2 - No foeld welding is required unless shown on plans. 3 - All fteld structural connections ore non-high strength baited connections os per approved perma pions. 4 - Type of work by llodisan Industries as shown on permit plans is subjected to normal Iocol jurisdiction's building deportment inspections as per 1994 U.B.C. section 108. The following, when applicable, sholl be under separate permits by OTHERS Signs Demofition Site Electrical Fuel systems Industrial waste Fire prevention Site Mechonical Site Plumbing Driveways Grading Paving Drainage Other Site Work FABRICATION: STRUCTURAL OBSERVATIONS - UBC Section 1702: Unless restricted by existing project site condaions and/or transportation fimitolions, sheet metal and/or steel structural components are fabricated as pre-assembled and/or pre welded modular subassemblies 0 t.todison Industries City of Los Angeles approved fabricator shop , 1 02. Unless speciflCOlIy required by the Iocol juriscflCtion's building offICial or specifted an permit plans, fteld structural observation is not required as per below listed reason(s): 1 - The types of structures ore not defined in table 16-k os Occupancy category I, II, or III. (see table 16-k for types of structures fisted os categories I, II, III.) 2 - The types of structures ore not required to comply with Section 403. (section 403 app~es to Group B office buildings and Group R Division 1 Occupancies.) 3 - t.todison Industrie's Engineer of Record waives the need for fteld structural observation. (Construction/structural erection is done by t.tadison Industries trained and experienced steel foeld erectors.) SHOP INSPECTIONS: Unless requested by local jurisdiction's building deportment's chief building offICial and/or specified on perma pions, steel and sheet metal prefabricated components da not require shop special inspection as per below listed reasan(s): 1 - All sheet metal/steel components ore fabricated and or welded at t.todison Industries City of Los Angeles approved fabricator shop 1102, and this fact. II approved by the lacal jurisdiction's building official, Eliminales the need for shop welding special inspectian as per 1994 U8C section 1701.5, subsection 5.1, exception no.1 and section 1701.7 PROJECT STRUCTURAL SITE ERECTION: NOTE: Unless local juriedlctlon building official disagrees, the below Hated documents are not applicable as noted lM'lder shoD in8Dections, field inspections and structural observations. 1 - Unless fteld welding is specified on permit pions, site structural steel/sheet metal erection consists of non-hi<)h strength boiled connections as shown on perma pions. 2 - Construction /structural erection is done by t.tadison Industries trained and experienced steel foeld erectors. 1 - Signing of SpecIal Inspection Testing Agreement. 2 - structtral Tests and Inspections Schedule. 3 - Letter of Agreement for structural Observation Any questions or comments in regards to above matters may be directed to Madison Industries Engineering Department Phone (213) 583-4061 Fax (213) 582-1015 _IMTE - "' I N'VO. [!J MADISON GENERAL NOTES / BPECFICATIONS CANOPES Sl>I,E, N/A -1'-0" 1lRIN.",~ 1llJ[, In/9I CHICO. or, lost up-dote 10-28-97 IIlITE'- C7-TC-139tvt GN-1 (CA) 1& 5lm Of A.E ... 7T139GHl l? ~ ,f ! -2 ~ ~ j ,. f 1 i ~ i ~ <> ~ i l!5 I '.a~._ I I I I (N) SHROLO (BY Mi) I I I I !I I ~I I <> ~ I'l ~I ~II I!? - (OW10 (0 Wl0 (E) Wl0 (OW10 ~ CANOPY ROOF PLAN ~:AT_II (N) t YJ'-3" ELEVAllON EB TYP. SHROUD DETAL ~ (E) 15 IOxl0 "mGSIIll' llII1f: IaI_PlINEL (E) W14 . I 'Of ;.., .. ,., '0. I X 1 X 2 X 18 GA. IlITSl:CTXlNS ,., i 20 1M. _ SIlmr/llUl1Ell Ia:9Ir _ "2>11" HIIH TEl< SCREWS w/ WASlOS . 8"..t. EXPOSED I()US COYER 10 I14TDt 0CCl( CN'I11l. EXTENSION ~ -J: ;u: SIRUlIlETM. CAPfTOI. 10 RElI!lN (E) 15 4,4 1 1/2" I 8 lit" 9' "RGSIEU.' 0IIl[ IaI_PlINEL ~G.\I.V' flASHING (CON!) ~~ I I I: lit--- 22GA GlLV. FlASHING I: I (CON!) SECTION EB 20GA GlLV. flASHING (CON!) 1-- ~~' I I I I I I I i I I I I 18 GA. 5.11. IlR1O<U 048- o.c. 1 1/2'" 8 1/2" 9' L2 l( 2 x 16 GA. 20 GA. SIl SlI'POIlT (2 - P[R COUIIlN) 20 GA. 0RNa SOfITT/GUffiR ACCENT IIo\ND 'EGGSHEll' WHIT[ N:JA FASCl\ PANEL '0. 1..' (E)WIDl l I I I I :r / <' tJ: DOWNSPOUT 10 RaM ~ LCAPfTOI. TO RIJlAlN "r 01 ;.., ~ ,., 20 GA. EGGSIlli wtf1[ UGH1WEU. SECllON EB EXBTI<<l STEB.., RCU.ED DECK, L.DfI'S TO IBWt _1DA.1E ........ or I..vo. [!J MADISON LF@~@@ 38'-0' x 50'-2' .oHXX..UMN CAHOP'( 78' IMAGE MOOFICATION IEW ROOF PLAN & ELEVA"TlONS .IOIIUlCAIIllIl - (N) t ]4'-6" 3/16' -1'-0" J;L 1/7/98 ~-==rC-139M (eA) CA-1 I S~N I ii sc.u,_ ORIN. II'.:. 01\1[,_ CIICO.l!!;. 01\1[, FI.... 7T1J9CAl ELEVAllON EB SHEIl or l;> t .r .. j '..... i'l 5 ~ &i :; ~ i ~ p. Ii ~ ~ ~ ~ /:j l5 l;. 0 s. .. ~ I ~.,,~~._- I """" -TI II ,--~.~~~- TI- II , ~.u_~ I I I I , II: I: "I "I .1 .1 Ii, Ii, I I I , ~.u_~ II _11. =l_~'::E_ llJl1IJl 4t EXISTNl CAW:Pf ROOF PLAN I, I I 120 :i Ig RIIlO\'E EXIST. SIRlUIlS ---, S' I~ II!! II II 50'-1 1/2' 010 or CAI<<lPI' EXIlT. aEV. EB II ___..lL_ , I I I I ! ! g I S' I-REIIlM EXIST. SIRlUIlS ~ 1 I!! I I I I I ., I ~ 3 I I I I J I 1 I I I I :! 112 :i I'" .--~ .14 TO _ 20 GA. EIIBOSSEIl ROllID IJ[CI( TO REllo\lN REIIlM--./j / GUl1(R ~ REIIlM ~ /" REIIlM sam '"' / 41.1 lMJlFUlW ....--_~ ~ EIIBOSSEIl CN'I1ll. 10 REM/oIN 1$ 10110 10_ 1$ 404 10_ SEC110N EB 20GA GllV. flASHI<<) 10 IE REIIlMO REW/E CON1INUOUS FIASHN; ~ , REIIlM 16 GA. S.IlZ. ~ ,I COIlPOSl1r AlIIIlIHUW FASCIA TO IE REIIlMO Of I IIVO. .10 10 REIM 1/4" , 1" ... 110I.1$ 10 IE REIIlMO COIIPOSIlE Al.I.UHLU FASCIA 10 IE REIIlMO SECTION EB IE '6' -:;T ~ ~ GvLL.-,J,o~~ ElOSTNQ STEB., AOU.ED DECK, L.JC>>fTIG TO IEMAIiI. I I I I 1 I I I~ !:- RIIlO\'E EXISTIlC 9flM --1: ~ ~ ~I I~ -I II!! I!!I I I I 1 I I I 201 ~I :C---:J"lol ==-="u ~I ~I I!! I _I MlE ....... [!J MADISON 'iJ'@@@@ 38'-0' X 50'-2' 4-cot..UMN CANIJPY 76' 1UA0E MODFICAllON EXISnoIQ .. DEMOLnlON PLAN .17'-11 1/-r 010 or CAI<<lPI' EXIBT.a.EV.@ Sl'.M[,_ -lit 001[,_ OICD. ~ 1>>01[: 3/16" -1'-1)" ~ 1/7/97 ~7-TC-139M leA) CE-1 I s~ I b. fIf No. 7T13l1CEl 5Im llf