08060096 CITY OF CUPERTINOgnwbPSiaF`f"`* -
BUILD-c.NGDIVISION PERMIT CONTRACTORIN�'ORM :T110N.
,,,„ 'vi,sRn""F1'ea 9 *:taYTr +.`
PERMIT NO
BUR,T5%'dS EEVES DR ERIK PETTIS 08060096
nW NER'S NAME: PERMYY ISSUE DATE
&YOUNG MEN S CHRISTIAN ASSOC 2053 JONESPORT AVE 06/12/2008
' O fjTi SANITARY NO. CONTROL NO.
(408) 230-8560
ARCHITECrrENGINEER: BUILDING PERMIT INFO
BLDG ELECT PLUMB MECH
�o'z LICENSED CONTRACT'OR'S DECLARATION I Job Description
F 1 hereby affirm Nu 1 am licensed under provisions of Chapter 9(commencing P
withSeeuan7aw)afDi.;aon3ofNeBaunessandProkcian,Code.andmyReenseis INSTL 3 PHAS 30 AMP DEDCTD CRCT TO NEW DRYR APPRX
^ N in full force and f4IOtl
;pz
Lice.Class tc ro Lia.y 85FT
aQARCHr1ECTS DECLARATION
W< 1 undrsunJ my
Phu Nall be used u Public records
y
y o� Licensed Proessirml
OWNER-BUILDER DECLARATION
gf 1 hereby afRrm that 1 am eacmpt from the Contractor's License law for the
OO following mason.(Section Tin 1.5,Business and Profession Code:Any city or county
C
<21! which requires a Permit to cmmnee alta,imprew,dmnitsh,or repair any surnew.
bit,to its issuance.also requires the applicant far such permit in file.signed uuentru
that he is licerectud potant to the powrisions of the Contractor's umbee LAW(chapter 9 Sq.Ft. Floor Area Valuation
sEa�O (commencing with Section 7")of Division 3 or the Business and Proressions Coic)or $2800
y $ that he is exempt therefrom and the basis for Ne alleged eumptic n.Any vWadon of
Section 7031.5 by any applicant for a permit subjects d applicant m a civil penalty of
net more than fiwhundred dollars( W). 32632 03 9 jVUq Number Occupancy Type
Q I,mowms of Ne proprsty,ermy wploym with wages mde'vuk campennden,
will do Professions
e wit and the ore Core h entintendd craw done
set.(Sac.Y(N4,Brener••
and property
W bu cella The Contractors rd who Law does set apply m m Owner is Required Inspections
ouncro wlmbuilds pounded emphases Nunn,andwho areasuch work co.frforlhnugh hh
bcwe .the WiNneach imPmwmmhare not enteredme@rod for suit.If,
however.the building or Improvement is old within on Maar of completion.the Owner.
Wilder will haw On burden of proving Nu he did ens hold or improv lar purpose of
sale.).
Q 1.an awmr of the property,am excluamly contracting with licensed contractors to
contnel the project(Sec.TW.Business and Profession Cotler)The Contractor's Li-
cenu law does not apply to an owns of property who builds or improses Nerve.and.
who mnmcts for surd projects with a centrssmri,)limned pursnnt to the Contractors
Law.
l am sec In undo see .B&PCfor this n
Dae
40Z
OTV RK S COMPENSATION DECLARATION
the. N�utper pens iy of perjuryarc of Ne fallowing dcdmtiom:
Q 1 h.w and will maintain s Cutfimte ofC...t m self-Imam forWorteeaCanpen-
.Won,an provided for by Section 3700 of the Luber Code.for de Nnfore atlm of the
work for which this Permit is issued.
Q 1 haw and will maincak Workers Compensation Isuvance,as required by Section
37W caf Ne saber Cod,for the purfa munce.f de work forwhich Nu permit is issued.
My Worker'.Compenpun.Insurance curies and Policy number am:
Cartier. Polity No.:
CERTIFICATE OF EXEMPTION FROM WORKERS
COMPENSATION INSURANCE
CThuuction rcW mthecanplevA if the permit is to ra ce hundred dollars(21001
or less)
I ratify Nal in the performance of the work for which Nis Permit is issued.I shall not
cutploy any person in any manorm as he become subject an the Worlo;rs'Compeo aeon
Laws of California.Date
Applicant
NOTICE TO APPLICANT:If.after making this Certificate of Esemption,you should
become crow to the Worker'.Compensation provisions of de labor Code,you most
.J z feMwith comply with such frrovsuon or this Penni)shall be darned mwkcd.
Z O CONSTRUCTION LENDING AGENCY
Ihereby affires NL them is a concerned..lending agency,for the Pvfarmance of
ori
Out work for which Thu Permit h issued(Sec.3097,Civ.C)
ft3 Q Lcndn's Name
7 z undYS Aekl
U O 1 certify that 1 ban read this application and sum that the.how information is
LL. coffin.I agree in empty with all my and county nNinarco and scale laws relating to
0 building construction,and hereby mNonm represenhtws of this city no enter upon the
purpose
above-nenuancdproperty for Inspection which may
�/`^r/WV
Er+y (We)agree m ssw,indemnify and kcep hamdess the Cly of Cup emus against
fn in
esunce of thegra.mdoftcnpomniLhmay in anY w+Y ancone agalmtsaiO Gty
t.)z in consequence of the granting of this permit.
APPLICANT UNDERSTANDS AND WILL COMPLY WITH ALL NON-POINT Issued by: Date
SOU�QEREG^U�'NS
y� ��l Re-roofs
Signalum of ApplresHAZA HAZARDOUS MATERIALS DISCLOSURE Type of Roof Wit]y the e Cupertino
nr future building e.Chapter
.handle e Iurallon material
m d.Sec io the Cupertino Municipal Code.Chapter 9.1x.roti de HaIN and Safety
ono Oyer 25532(a)7 All roofs shall be inspected prior to any roofing material being installed.
QYes Y�No
/_ If a roof is installed without first obtainingan inspection,I agree to remove
Will the applicant or future building aoupam esu equipment or Jcvims which P g
.mil hnandnus air contaminants u defied by Ne Bay Area Air Quality Management all new materials for inspection.
DiavicR J
QYes yd No
1 haw,mad the hand/oro mammals requirements a eurchapmr G95 of the Califor.
.is Hesl"SaftyCrdc,Sections,25505.x5533 and 25534.1 understand dead iftho Wilding
den ens currently haw a tenant that it is,my revponiMlily to entry the occupant of the
regeare .=men ' rth traamancmtinaateofaapanry. Signature of Applicant Date
unjw
Owner or auahouud.gem Da All roof coverings to be Class'As'or better
CITY OF CUPERTINO
3 ITEMS OF 3 PERMIT RECEIPT OPERATOR: pdtg
COPY # 1
Sec : Twp: Rng: Sub: Blk: Lot:
APN . . . . . . 1 . : 32632039 . 00
DATE ISSUED. . . . . . . : 06/12/2008
RECEIPT # . . . . . . . . . : BS000005097
REFERENCE ID # . . . : 08060096
SITE ADDRESS . . . . . : 20803. ALVES DR
SUBDIVISION . . . . . . .
CITY . . . . . . . . . . . . . : CUPERTINO
IMPACT AREA . . . . . . .
OWNER . . . . . . . . . . . . : YOUNG MEN S CHRISTIAN ASSOC OF
ADDRESS . . . . . . . . . . : 20803 ALVES DR
CITY/STATE/ZIP . . . : CUPERTINO, 95126-1704
RECEIVED FROM . . . . : ERIK PETTIS
CONTRACTOR . . . . . . . : ERIK PETTIS LIC # 28236
COMPANY . . . . . . . . . . : ERIK PETTIS
ADDRESS . . . . . . . . . . : 2053 JONESPORT AVE
CITY/STATE/ZIP . . . : SAN JOSE, CA 95131
TELEPHONE . . . . . . . . : (408) 230-8560
•
FEE ID UNIT QUANTITY AMOUNT PD-TO-DT THIS REC NEW BAL
---- ------------- ---------- ---------- ---------- ---------- ----------
1BSEISMICO VALUATION 2 , 800 . 00 0 . 63 0 . 00 0 . 63 0 . 00
IEPERMITFE FLAT RATE 1 . 00 40 . 79 0 . 00 40 . 79 0 . 00
1TRAVDOC FLAT RATE 1 . 00 40 . 79 0 . 00 40 . 79 0 :00
---------- ---------- ---------- ----------
TOTAL PERMIT 82 . 21 0 . 00 82 . 21 0 . 00
METHOD OF PAYMENT AMOUNT REFERENCE NUMBER
----------------- --------------- --------------------
CREDIT CARD 82 . 21 VISA
---------------
TOTAL RECEIPT 82 . 21
CITY OF CUPERTINO
CUPEkTINO GENERAL BUILDING
PERMIT APPLICATION FORM
APN # aDate:
z�3q� �
Building Address:
I
Z-0 �03 A 1 ues f2
Mailing Address (if different from building address):
Owner's Name: Phone#:
C ntractor: Phone:
�r Fax:
Contractor License#: g \A-7 J S
Cupertino Business License#:
• Contact: Phone:
N -0)� Fax:
Residential Commercial
Job Description: Lns �a/� 3PJ+ws z )o .f Ago Z>eo )-e-el d C, -C, cf f,>
/I�e�j />�y,� e 'r'-
Building Permit Info:
Bldg ❑ Elect 5 Plumb ❑ Mech El
Type of Construction (Usage Class): Occupancy Type:
1-A, 1-B ❑ II/IIIN-A ❑ II/III B, IV-HT, V-B vl
Valuation: Square Footage:
TZ 6�oo
• Project Size: Standard ❑ Large ❑ Major ❑
Revised 5/21/08
«e CITY OF CUPERTINO
CUPEkT[NO GENERAL BUILDING
PERMIT APPLICATION FORM
Quantity/Sf Fee ID Fee Description Fee Permit Type
Group 1GENRES or
1GENCOM
1 BTEMPPER Temporary Building Permit (good for B
30 days)
1 BBOILERI For the installation or relocation of ea M
boiler/compressor to & including 3
horsepower, or ea absorption sys to &
incl 100,000 Btu/h (29.3kw)
1BBOILER2 Installation/relocation of ea M
boiler/compressor over 3 horsepower
to &incl 15 horsepower, or ea
absorption ss over 100,000 Btu/h
1BBOILER3 Install ation/relocation of ea M
boiler/compressor over 15 horsepower
to & incl 30 horsepower, or ea
absorption sys over 500,000 Btu/h to •
& incl 1,000,000 Btu/h
1 BBOILER4 Installation/relocation of ea M
boiler/compressor over 30 hosepower
to & incl 50 horsepower, or for ea
absorption sys over 1,000,000 Btu/h to
& incl 1,750,000 Btu/h
1 BBOILER5 Installation/relocation of ea boiler or M
refrigeration compressor over 50
horsepower, or ea absorption sys over
1,750,000 Btu/h
1 BAPPLOTH For ea appliance or piece of equip M
regulated by this Code but not classed
in other appliance categories, or for
which no other fee is listed in this
code.
1 ELECINSP Other Electrical Inspections (per hour) E
1 MECHINSP Other Mechanical Inspections (per M
hour)
1PLMBINSP Other Plumbing& Gas Inspections P •
er hour)
1MEETINGIHR Application Meeting B
anCITY OF CUPERTINO
CUPCITY EYOF GENERAL BUILDING APPLICATION
FEE SCHEDULE
Quantity/Sf Fee ID Fee Description Fee Permit Type
Group 1GENRES or
1GENCOM
ACOUSTICAL
REVIEW
IACOUSFDW SFDWL/Duplex New B
IACOUSRESAD SFDWL/Duplex-Addition/Alteration B
IACOUSCOM Multi-Family/Commercial B
CHIMNEY'S
1CHIMNEY Chimney B
1 CHIMNEYR Chimney Repair B
FENCES
1 FENCE>6FT Non-masonry, over 6 ft in height B
1 FENCEMAS>6 Masonry, over 6 ft in height B
FIREPLACES
1FIREPLMAS Fireplace Masonry B
1FIREPLFAB Fireplace Pre-Fabricated/Metal B
I FLAGPOL>20 Flag pole (over 20 ft in height) B
1MODUSTRU Modular Structures B
FOUNDATIONS
IFOUNDREP Foundation Repair B
1 PILECAST Pile Foundation Cast in place concrete B
1 PILEDRIV Pile Foundation Driven (steel, pre- B
stressed concrete)
3 of 5
arc
CITY OF CUPERTINO
CITY OF GENERAL BUILDING APPLICATION
CUPER,TINO
FEE SCHEDULE
Quantity/Sf Fee ID Fee Description Fee Permit Type
Group 1GENRES or
1GENCOM
RETAINING
WALL(CONCRETE
OR MASONRY
1 RETSTN Standard (up to 50 ft) B
1 RETSP310 Special Design, 3-10' high (up to 50 `) B
1RETSPIO Special Design, over 10' high (up to B
50')
1RETCRB< Gravity/Crib Wall, 0-10'high (up to B
50 ft
1RETCRB> Gravity/Crib Wall over 10' high (up to B
50 ft)
SIDING
1SIDEST/BK Siding, Stone & Brick Veneer B •
(interior/exterior)
1 SIDEOTHER Siding all other B
SKYLIGHTS
1 SKYL<10 SF Skylight less than 10 sf B
1 SKYL>1 OSF Skylight greater than 10 sf or B
structural
1STAIRS Stairs-first flight/ea addt'1 B
STORAGE RACKS
1 SRACKS<=8 Storage Racks 0-8' high (up to 100 sf) B
1 SRACKS>8 Storage Racks over 8' high (up to 100 B
st)
ISTUCOAP Stucco Applications (up to 400 sf) B
additional stucco application
•
4of5
CCS CITY OF CUPERTINO
CITY OF GENERAL BUILDING APPLICATION
CUPERTINO FEE SCHEDULE
Quantity/Sf Fee ID Fee Description Fee Permit Type
Group 1GENRES or
1GENCOM
1 WINREP Replacement windows/sliding glass B
door (ea 8 windows)
1WINMEWSTR New Window-structural shear B
wall/masonry (includes plan ck fee)
IEPERMITFEE Electrical Permit Fee E
1 MPERMITFEE Mechanical Permit Fee M
I PPERMITFEE Plumbing Permit Fee P
1 ELCPLNCK Stand Alone Electric Pln Ck (hourly) E
1 MECPLNCK Stand Alone Mechanical Pln Ck (hrly) M
1PLMBLNCK Stand Alone Plumbing Pln Ck (hrly) P
1 STPLNCK-(3 Hr Min Standard Plan Check (when
when not over counter) hourly-stand alone
1 BSEISMICR Seismic Residential B
1BSEISMICO Seismic Commercial B
/ 1TRAVDOC Travel & Documentation B
1BUSLIC Business License B
•
5 of 5
Green Building Plan Check
Index of Green Building Points/Categories
A. Category Example of an Index or Table of Green Plan Sheet or Page Points
Building Points Categories that must be
shown and referenced on the Project
Plans See below
B. Site 9. Install H.E. Irrigation, (details/spec)' L-1 2 points
11. Permeable Paving, Note L-1 2 oints
C. Foundation 1. Use 15 % Flyash Concrete, (note) S-1 5 points
D. Structural 3. Uses Wood I-Joist, (See Spec.) S-2 2 points
5. Use Truss with heels, (detail) S-2 2 points
6. B. OSB Sheathing, detail S-2 2 points
E. Ext. Finish 1. Composite Decking, (Note/Spec.) A-3 2 points
4. B. Fiber Cement Siding, (Note/Spec. A-4 2 points
F. Plumbing 1. Insulate all H.W. pipes, (Note/Spec.) P-1 2 points
5. Tankless W.H., (Note/Spec.) A-2 2 points
11. A 2500 Gal. Tank, (Note/Spec L-1 10 points
G. Electrical 4. E. Ceiling Fans, (Note/Spec.) A-3 4 points
H. Appliances 1. Energy Star Dishwasher, (Note/Spec.) A-3 1 point
3. Energy Star Refrigerator, (Note/Spec. A-3 1 point
P. Other 1. List Green Features on Plans A-1 1 point
TOTAL POINTS 40 points
•
•
Plan Review Proce
ss Werk look Page-12-Revised 3/25/0E
Green Points Rating System for Remodeling Projects
Due to the diversity of remodeling project types,assigning a"total points'value to a project to be considered environmentally friendly is
not feasible. However,25 measures have been highlighted to signify that every effort should be made to incorporate them into your
projects. These items have been chosen based upon their impact on the environment and the health of the home in coordination with
ease of implementation and relative low cost. These measures can be used as a starting point for"greening'your project.
IL site INPUT Resvurces Energy 1AWHeafth
1.Recycle Job Site Construction&Demolition Waste
65%=1 point;75%= 2 points;BO%=4 points f up to 4 Resource pts 0
2.Salvage Reusable Building Materials i 4 Resource pts y=yes 0
3.Remodel for Mixed Use,Adaptive Reuse,and
Historic Preservation 4 Resource pts y=yes 0
4.Protect Native Soil 2 Resource pts y=yes 0
5.Minimize Disruption of Existing Plants&Trees 1 Resource pt y=yes 0
6.Implement Construction Site Stormwater Practices 2 Resource pts y=yes 0
7.Protect Water Quality with Landscape Design 2 Resource pts y=yes 0
8.Design Resource-Efficient Landscapes and Gardens ^ _J 4 Resource pts y=yes 0
9.Reuse Materials/Use Recycled Content Materials
for Landscape Areas 2 Resource pts y=yes 0
10.Install High-Efficiency Irrigation Systems 2 Resource pts y=yes 0
11.Provide for On-Site Water Catchment/Retention 2 Resource pts y=yes 0
1 1
B.Foundation 1
• 1.Incorporate Recycled Flyash in Concrete
25%Recycled Flyash=2 points;Add 1 point for every 10%
increase of flyash,up to 5 points up to 5 Resource pts 0
2.Use Recycled Content Aggregate 2 Resource pts y--yes 0
3. Insulate Foundation/Slab before backfill 3 Energy pts y--yes 0
1
C.Structural Frame 1 1
.1.Substitute Solid Sawn Lumber with Engineered Lumber _J 3 Resource pts y--yes 0
2.Use FSC Certified Wood for framing
(For every 10%of FSC lumber used=2 points,up to 10) up to 10 Resource pts. 0
3.Use Wood I-Joists for Floors and Ceilings 2 Resource pts y=yes 0
4.Use Web Floor Trusses 2 Resource pts y--yes 0
5.Design Energy Heels on Trusses 6°or more 2 Energy pts y=yes 0
6.Use Finger-Jointed Studs for Vertical Applications 2 Resource pts y--yes 0
7.Use Engineered Studs for Vertical Applications 2 Resource pts y=yes 0
B.Use Recycled Content Steel Studs for Interior Framing 2 Resource pts y=yes 0
9.Use Structural Insulated Panels(Sips)
a.Floors
3 Energy pts y yes p
b.Wall 3 Energy pts y=yes 0
C.Roof 3 Energy pts y=yes 0
10.Apply Advanced Framing Techniques 4 Resource pts y=yes p
11.Use Reclaimed Lumber for Non Structural Applications 3 Resource pts y=yes p
12.UseOSB — -- — – –" —
• a.Subfloors — 1 Resource pt y=yes 0
b.Sheathing
1 Resource pt y=yes p
1 1 1
D. error Finish
ji.Use Susiainable Decking Materials y
a.Recycled content 3 Resource pts y=yes 0
{I b.FSC Certified Wood 3 Resource pts y=yes 0
!2.Use Treated Wood That Does Not Contain Chromium/Arsenic i 1 IACUHealth pt y--yes D
13.Install House Wrap under Siding ) 1 IAQ/Health pt y=yes 0
I4.Use Fiber-Cement Siding Materials f _ _vv _ I 1 Resource pt y--yes 0
E.Plumbing
1.Install Water Heater Jacket 1 Energy pt y--yes 0
2,Insulate Hot and Cold Water Pipes 2 Energy pts Y--yes 0
3.Retrofit all Faucets and Showerheads with Flow Reducers.
a.Faucets(1 point each,up to'2 points) Up to 2 Resource pts. 0
b,Showe heads(1 point each,up to 2,points) Up to 2 Resource pts. 0
4.Replace Toilest with Ultra-Low Flush Toilets
(1 point each,up to 3 points) Up to 3 Resource pts. 0
5.Install Chlorine Filter on Showerhead 1 IAQ/Health pt y=yes 0
6.Convert Gas to Tankless Water Heater 4 Energy pts y=yes 0
7.Install Water Filtration Units at Faucets
(2 points each,up to 4 points) Up to 4 IAQ/Health pts. 0
B.Install On-Demand Hot Water Circulation Pump 4 Resource pts y--yes 0
I I 1
r,.neccricai
1.Install Compact Fluorescent Light Bulbs(CFIs) T
(6 bulbs=2 points,10 bulbs-_3 points,12 bulbs=4 points) Up to 4 Energy pts. 0 •
2.Install IC-AT Recessed Fixtures with CFLs(1 point each,up to
5 points) Up to 5 Energy pts. 0
3.Install Lighting Controls(1 point per fixture,up to 4 points) Up to 4 Energy pts. 0
4.Install High Efficiency Ceiling Fans with CFLs
(1 point each,up to 4 points) Up to 4 Energy pts. 0
t 1 1
G.Appliances
1.Install Energy Star Dishwashe( ��—I 1 Energy pt y=yes 0
2.Install Washing Machine with Water and Energy i
Conservation Features 1 1 Energy pt y=yes 0
3.Install Energy Star Refrigerator, V 1 Energy pt y=yes 0
4.Install Built-In Recycling Center ,i 3 Resource pts y=yes 0
H.Insulation
1.Upgrade Insulation to Exceed Title 24 Requirements
a.Walls 2 Energy pts Y--yes 0
b.Ceilings 2 Energy pts y=yes 0
2.Install Floor Insulation over Crawl Space 4 Energy pts Y--yes 0
3 Install Recycled-Content,Fiberglass Insulation`wifi
NoAdded Formaldehyde — ( 31AQ/Haalth pts y=yes 0
�___ _
4.Use Advanced Infiltration Reduction Practices 2 Energy pts y=yes 0
5.Use Cellulose Insulation
a,Walls 4 Resource pts y=yes 0 •
b.Ceilings 4 Resource pts y=yes 0
6.Alternative Insulation Products(Cotton,spray-loam)
a.Walls 4 Resource pts y=yes D
D.t;enings 4 Resource pts y=yes 0
1
INPUT ResDurces Energy IAWKeaItt_—
I.Wrn ows
ft.Install Energy-Efficient Windows 1
a.Double-Paned 1y 1 Energy pt y=yes D
b.Low-Emissivity(Low-E) 2 Energy pts y=yes 0
c.Low.Conductivity Frames 2 Ener is
__-- 9YP y yes 0
2.Install Low Heat Transmission Glazing 1 Energy pt y=yes D
1 1 1
J.Heating Ventilation and Air Conditioning
[i.Use Dud Mastic on All Duct Joints _ 2 Energy pis y=yes D
2.Install Ductwork within Conditioned Space 3 Energy pts y=yes 0
3.Vent Range Hood to the Outside 1 IAD/Health pt y=yes 0
4.Clean all Ducts Before Occupancy 2 IAO/Health pis y=yes 0
5.Install SolarAttic Fan 2 Energy pts y=yes 0
6.Install Attic Ventilation Systems 1 Energy pt y=yes 0
7.Install Whole House Fan 4 Energy pts y=yes 0
B.Install Sealed Combustion Units
a.Furnaces 31AQ/Health pts y=yes 0
b.Water Heaters 31AQ/Health pts y=yes 0
9.Replace Wall-Mounted Electric and Gas Heaters with
Through-the-Wall Heat Pumps 3 Energy pts y=yes 0
10.Install 13 SEER/11 EER or higher AC with a TXV 3 Energy pts y=yes 0
11.Install AC with Non-HCFC Refrigerants 2 Resource pts y=yes 0
12.Install 90%Annual Fuel Utilization Efficiency(AFUE)Furnace 2 Energy pts y=yes 0
• 13.Retrofit Wood Burning Fireplaces
a.Install EPA certified Wood stoves/inserts 1 1A0/Health pt y=yes 0
b. Instali/Replace Dampers 1 Energy pt y=yes 0
c.Install Airtight Doors 1 Energy of y=yes 0
14.Install Zoned,Hydronic Radiant Heating 3 Energy pis y=yes 0
15.Install High Efficiency Filter 41AC/Health pts y=yes 0
16.Install Heat Recovery Ventilation Unit(HRV) 5 IAQ/Health pts y=yes 0
17.Install Separate Garage Exhaust Fan 3 IAQ/Health pts y=yes 0 .
1 ! 1
K.Renewable Energy and Roofing
1.Pre-Plumb for Solar Water Heating 4 Energy pts y=yes 0
2.Install Solar Water Heating System 10 Energy pts y=yes 0
3.Pre-Wire for Future Photovoltaic(PV)Installation 4 Energy pis y=yes 0
4.Install Photovoltaic(PV)System
(1.2 kw=6 points,2.4 kw=12 points,3.6 kw=18 points) Up to 18 Energy pts 0
6 SSelect Safe and Durable Roofing Malenals - 1 Resource pt y=yes 0
7,Install Radiant Bartier 3 Energy pts y=yes 0
1 1
L.Natural Heating and Cooling 1
1.Incorporate Passive Solar Heating 5 Energy pts y=yes p
2.Install Overhangs or Awnings over South Facing Windows 3 Energy pis y=yes p
3.Plant Deciduous Trees on the West and South Sides 3 Energy pts y=yes D
• 1 1 1
INPUT ReSDUTCeS Energy JAWHealth
_W5 Air Quality and Finishes '
Use Low No•VOC Pant 1 IAO/Heaith pts y=yes 0
2.Use Low VOC,Water-Based Wood Finishes 2 IAQ/Heaith pts y--yes D
13,Use_Low/No VOC Adhesives _ `_ i 3IAQ/Health pts y--yes 0
4.Use Salvaged Materials for Interior Finishes 3 Resource pts y--yes D
5.Use Engineered Sheet Goods with no added Urea
Formaldehyde 61AQ/Health pts y=yes 0
6,Use Exterior Grade Plywood for Interior Uses 1 IAQ/Health pts y--yes 0
eal all Exposed.Particleboard or MDF .. "_ _ 41AQ/Health pts y=yes 0
8.Use FSC Certified Materials for Intedor Finish 4 Resource pts y=yes 0
9.Use Finger-Jointed or Recycled-Content Trim 1 Resource pts y=yes 0
1 1
10.Install Whole House Vacuum System 3 IAQ/Health pts y=yes 0
1 1 1
N.Flooring
1.Select FSC Certified Wood Floodng 8 Resource pts y--yes 0
�2.Use Rapidly Renewable FloodngMaterials �__f 4 Resource pts y--yes 0
3.Use Recycled Content Ceramic Tiles 4 Resource pts y,--yes 0
4.Install Natural Linoleum in Place of Vinyl 5 IAQ/Health pts y=yes 0
5.Use Exposed Concrete as.Finished Floor 4 Resource pts y=yes 0
6.Install Recycled Content Carpet with Low VOCs 4 Resource pts y=yes 0
1 1
Total Points Available: 1 1401 130 57 .
Total Points Project Received: 1 01 0 0
G:datarprogsigreenbuilSngguidelin:shemodeleNgreenpamsfinat272.04pmle.ledxis