Loading...
11110173 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADD RESS:1'0495 BANDLEY DR CONTRACTOR:STATEWIDE PERMIT NO: 11110173 ROOFING INC OWNER'S NAME: RICHARD FOOLEY 5542 MONTEREY RD DATE ISSUED: 11/30/2011 vNER'S PHONE: SAN JOSE, CA 95138 PHONE NO:(408)288-8680 LICENSED CON'rRAC'I'Olt'S DI,'CLA1tAq'ION BUILDING PERMIT INFO: Ul.nc F.Lecf v1.Umn License Class m Lic.qQ� 26 r r r MECH RESIDENTIAL COMMERCIAL Contractor ate — �^ 1 hereby affirm that I am licensed under t rovisions of Chapter 9 JOBDESCRIPTION: COMM RE-ROOF28 SQOVERLAY W/TPO (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$26000 1 have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:32633108.10495 Occupancy Typc: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to comply with all city and county ordinances and state laws relating WITHV8DYS OFPERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enterupon the above mentioned property for inspection purposes. (We)agree to save 180 DALAST CALLED INECTION indemnify and keep harmless the City of Cupertino against liabilities,judgments, — cosls,and expenses which may acem aga t said City in consequence of the granting of this permit. A ilio ,t applicant understands and will comply Issued by: Date: with all non-point sou re ioi per the Cupertino Municipal Code,Section 9.18. Signature Date 11-30- Zoll ROOFS: All roofs shall be inspected prior to any roofing material being insmlled. If a root'is installed without first obtaining an in pec gree to remove all new materials for inspection. OWNER-BUILDER DECLARATION Signature of Applicant: Date: ��� Y�— ZY 1 hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS'I'O BE CLASS"A"OR BM:I"fEl2 I,as owner of the property,or my employees with wages as their sole compensnlion, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the properly,am exclusively contracting with licensed contractors to HAZARDOUS MA'1'FRIAI,S DISCLOSURE DISCLOSURE construct the project(Sce.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California health&Safety Code,Sections 25505,25533,and 25534. 1 will I hereby nlTirm under penalty of perjury one of the fallowing three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should 1 stare or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should 1 use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Buy Arca Air Quality Management District 1 performance of the work for which this permit is issued, will maintain compliance with the Cupertino W icipal Code.Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Ilcalth&Safety Code,Sections 2- 5, - ,and 25534. Section 3700 of the Labor Code,for the perlbrmance of the work for which this permit is issued. Owner or authorized agent: Date. I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTIIUCTION LENDING AGENCY AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save AIICIIII'EC'I"S DECLARATION •ramify and keep harmless the City of Cupertino against liabilities,judgments, and expenses which may accrue against said City in consequence of the 1 understand my plans shall be used as public records. ting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date ' REROOF PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 • C (408)777-3228•FAX(408)777-3333•buildingAcupertino.org PROJECT ADDRESS liqy9S !fie I APN# 3/7 /p )C) /�4141� OWNERNAME F�L Q�v E-MAIL l../ {-I STREET ADDRESS OD / CTTV, TE,ZIP So FAX CONTACT NAME PHONE E-MAIL �o4-S9/- 2 sv STREETADDRESS CITY,STATE, ZIP FAX ❑OWNER ❑ OWNER-RI BDER ❑ OWNERAGENT X CONTRACTOR ❑CONTRACTORAGENT ❑ ARCHITF r ❑ENGINEER ❑ DEVP.LOPER ❑ TENANT CONTRACTOR NAME C / -/ 011 LICENSE NUMBER Q�/ LICENSETYPE , Q BUS,LIC.# 3,53 140 COMPANY NAME ,r u-C T) ,,,rrr 4- E-MAIL /Dl / RAX /CJ��� STREET ADDRFML.3yV2 yyZ j CITY, 1;,E,ZIP O PHONE ARCHTTL'CT/ENGINEER NAME LICENSENUMBER BUS,LIC.# COMPANY NAME EMAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF ❑ SFD or Duplex ❑ Multi-Family ROOF AREA7��7;11ry ALUATIONTRucruRe: Commercial �(p EXISTINGROOFTYPE: ❑BUILT-UPROOP ❑ASPHALT SHINGLES ❑WOODSHAKES ❑WOODSHINGLES ❑OTHER(SPECIFY) REMOVE/REPLACE IF NO. PLYWOOD ❑ 'h" ❑ PLYWD ❑OSB PITCH: ROOF ❑ q 1 ❑ Pn ❑ :12CLASS A PROPOSEDROOFTYPE: ❑BUILT-UPRWF ❑ASPHALT SHINGLES ❑WOOD SHAKES ❑WOODSHINGLES ❑OTHER ICC-ES REPORT# DESCRIPTION OF WORK: /tQla. Y G�-i'G dL a T/"O cc s S S By my signature below,I certify to each of the follow I am t e property owner or authorized agent to act on the property owner's behalf. I have read this application and the information 1 have p I e the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state 1 retati n. u Yin representatives of Cupertino to enter the above-identified proper/p'for inspection purposes. Signature of Applicant/Agent Date: J[7 'ZD�/ SUPPLE ENTAL INFORMATION REQUIRED OFFICE USE ONLY _If building is associated with a Home Owners Association,provide letteru PLAN CHECK TYPE ROUTING SLIP Xof approval from HOA. OVER-THE-COUNTER ❑ BUILDING PLAN REVIEW _Provide Planning approval to verify if there any restrictions. ❑ EXPRESS ❑ PLANNING PLAN REVIEW Provide copy of Manufacturer's Installation Specifications. ❑ STANDARD ❑ FIRE DEPT Provide signed copy of Cupertino s Tear-Off Policy. ❑ OTHER: ReroofApp_2011.doc revised 03/16/11 REROOF TEAR-OFF POLICY COMMUNITY DEVELOPMENT DEPARTMENT-BUILDING DIVISION ALBERT SALVADOR, P.E., C.B.O., BUILDING OFFICIAL • CUPERTINO 10300 TORRE AVENUE-CUPERTINO, CA 95014-3255 (408) 777-3228-FAX(408)777-3333-buildingacupertino.org PROJECT ADDRESS �oy�s` Dr. I APN0 OWNERNAME t PHONE q08 /-Z O E-MAIL STREEI'ADDRESS D ) Q /(� . S CITY, ST)jl'C,ZIP O. IA D/ FAX CONTRACTOR NAMP� �('4.1 LICENSENUMBE �� {"/LICENSA'TYPE BUS.LIC.M COMPANY NAME E-MAIL ( FAX#08 a4 -78 zo S/STREET ADDRESS n I CITY,STATE,T.IP e PHONE L�V2 I UNDERSTAND AND AGREE TO THE FOLLOWING: 1. The re-roof project shall comply with all applicable provisions of the 2007 California Building Code. 2. You must schedule all needed inspections a minimum of one day before the requested inspection date. Please schedule inspections online or call (408)777-3228 between 7:30-3:30 (Mon-Fri). 3. Tear-off roof inspection is required. Please call for tear-off inspection after the roof is torn off and all the nails/fasteners have been removed. Any and all dry-rotted wood shall be replaced prior to this inspection. A building inspector will be available within one hour. • There are special hours for this service: 7:30 — 10:30am and 1:00—3:30pm (Mon—Thurs); 7:30 — 10:30am and 1:00—2:30pm (Friday). 4. If plywood is installed, a plywood nailing inspection is required. 5. In-Progress roof inspection is required. Call for an in-progress roof inspection to verify building is weather tight after installation of approximately 25% of the roofing material. 6. New roof coverings shall not be applied without first obtaining all inspections and written approvals from the building inspector. Any roofing which is applied without first obtaining an approved inspection will require the removal of all new material down to the sheathing so a proper inspection can be performed. 7. A final inspection and approval shall be obtained from the building inspector when the re-roofing is complete. To receive a final sign-off, the following items will be verified: a. Flat roofs shall have a minimum of/d' per foot of slope and must demonstrate there is no ponding. b. Listings from approved testing agencies for all pre-manufactured products used shall be available on-site to review at the time of the inspection. c. Proper spark arrestor installation. 8. NOTE: If you call for a tear-off or plywood nailing inspection and the work is not complete,you will be charged a re-inspection fee of$126.00. The re-inspection fee shall be paid before another inspection can be scheduled. is, y my signing below, I certify eVutand following is true: I am the property owner or authorized agent to act n the property owner's beh and agree to comply with the re-roof policy stated above. ignature of Applicant/Agent: Date: 1/-30-Z01/ ReroofPolicy_2010.doc revised 05/17/10 CITY OF CUPERTINO • 3 ITEMS OF 3 PERMIT RECEIPT OPERATOR: SylviaM COPY # 1 Sec : Twp: Rng: Sub: Blk: Lot : APN . . . . . . . . : 32633108 . 10495 DATE ISSUED. . . . . . . : 11/30/2011 RECEIPT #. . . . . . . . . : BS000015438 REFERENCE ID # . . . : 11110173 SITE ADDRESS . . . . . : 10495 BANDLEY DR SUBDIVISION . . . . . . CITY CUPERTINO IMPACT AREA . . . . . . OWNER . . . . . . . . . . . . : RICHARD FOOLEY ADDRESS . . . . . . . . . . : 10495 BANDLEY DR CITY/STATE/ZIP . . . : CUPERTINO, CA 95014 RECEIVED FROM . . . . : STATEWIDE ROOFING CONTRACTOR . . . . . . . : KYLE HYPES LIC # 23509 COMPANY . . . . . . . . . . : STATEWIDE ROOFING INC ADDRESS . . . . . . . . . . : 5542 MONTEREY RD CITY/STATE/ZIP . . . : SAN JOSE, CA 95138 TELEPHONE . . . . . . . . : (408) 288-8680 • FEE ID UNIT QUANTITY AMOUNT PD-TO-DT THIS REC NEW BAL ---------- ------------- ---------- ---------- ---------- ---------- ---------- 1BCBSC VALUATION 26, 000 . 00 2 . 00 0 . 00 2 . 00 0 . 00 1BSEISMICO VALUATION 26, 000 . 00 5 .46 0 . 00 5 .46 0 . 00 1REROOFCOM SQUARES 28 . 00 359 . 00 0 . 00 359 . 00 0 . 00 ---------- ---------- ---------- ---------- TOTAL PERMIT 366 .46 0 . 00 366 .46 0 . 00 METHOD OF PAYMENT AMOUNT REFERENCE NUMBER ----------------- --------------- -------------------- CREDIT CARD 366 .46 VISA --------------- TOTAL RECEIPT 366 .46 VOICE ID DESCRIPTION VOICE ID DESCRIPTION -------- ---------------------------- -------- ---------------------------- 309 EXTERIOR LATH 311 SCRATCH COAT 601 ROOF TEAR OFF 602 ROOF PLYWOOD NAIL 604 ROOF IN-PROGRESS 605 FINAL REROOF • CITY OF CUPERTINO J 0/ 73 FEE ESTIMATOR- BUILDING DIVISION • ADDRESS: 10495 Bandley Dr. DATE: 11/30/2011REVIEWED BY: APN: BP#: I *VALUATION: $26,000 *PERMIT TYPE: Minor Building Permit PLAN CHECK TYPE: Re-roof PRIMARY Commercial Building PENTAMATION 1COMMLROOF USE: PERMIT TYPE: WORK overlay with TPO SCOPE FEE 1D ROOFAREA s.f. 1REROOFCOM 2,800 ;Nech. Plnn Check Phwlh. Flan Cite,k E1e,.P1en Cl ct k Mech. Peril P'es: Phnnh.Pen "I hee; Glnc. Pet wit Fero.' Other'ltech.Imp. Other Ylmnh Imp. Odwr E/er,hop. ED :tlech. hlsp. Fee: P(unrh. hiep. ]"ec; hh',hnp, f-'eer NOTE: This estimate does not Include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc. . These fees are based on therelimina Information available and are only an estimate. Contact the Dept for addn'I info. FEE ITEMS (Fee Resolution 11-0531:T. 7/1/11) FEE QTY/FEE MISC ITEMS Phan (.'hack Ve:e- Stippl. PC Fee Plainh./Me ch./Pelee Perm it Fee: $359.00 Svppl. Imp Fee Plutnh.4Lfech./Elec Plumb.lMech./Eley.Permir Fee.: Cornstruetian Ta.v Achninistrative Fee: Work Without Permit? O Yes 0 No $0.00 Advanced Planning Fees: Travel Documentation Fees:• Strone Motion Fee: /BSBISMICO $5.46 Select an Administrative Item • Blcte Stds Commission Fee: iBCBSC $2.00 SUBTOTALS: $366.46 $0.00 TOTAL FEE: $366.46 Revised: 10/01/2011 ' i ' 'd CARLISLE'S® RE,,CRIVED S1J"mWELM 3 0 2011 „ �'�:, W.31,MTced w die Membrane . s Carlisle Fasteners and Plates ��yJV�I fr�. l�.' ,L Acceptable Insulation ILI"' l4"; ytF n d+t ' 0 Approved Roof Deck 10, System features and benefits include: • Hem-weldable membranes ell • High wind uplift performance ". - • Hall and high puncture resistance `tT 1 •Top ply membrane thickness adds improved long-term weatherability and durability ..„.,,: • Sure-Weld membrane meets fill,t' I P ENERGY STAR*guidelines Sure-Weld Membrane for Mechanically-Fastened • Systems is available in the following- Colors: ollowingColors:White,Gray,Tan Thickness (mils):45,60,72 and 80 Standard Widths:6',8', 10'and 12' Standard Lengths: 100' NEW CONSTRUCTION '; "M' '°'RERQOF,,INGWAV EXISTING OR OO rr OO STEEL r 'r EXISTING NEW DECK TYPE CONCRITrEPLANKS CEMENT BUR . p, , CONCRETE r UR SINCLE-PLY DECK OVERLAYMENT INSULATION NO NO HP MAT INSULATION INSULATION NO INSULATION *REFER TO REQUIRED SPECS RECOMMENDED s' ' , 'CARLISLE POLYISO,CARLISLE HP RECOVERY BOARD OR rCARLISLEAP RECOVERY BOARD OVER POLYSTYRENE'. t t-REFER TO NEW.CONSTRUC710NH � E= sem.. y, N INSULATION CARLISLE FASTENERS AND PLATES -4—REFER TO NEW CONSTRUCTION ATTACHED BY 'HPX 'NPK F06NIM � FASTENEIW PIRANHA PIRANHA LWfECK TW7 MEMBRANE DECK' ATTACHED 9Y tNPRA� FFLTS FN ; fr REFER NEW CONSTRUCTION PXTRA a AA AST/ RAEH0,14-10 PIRANHA As ' PIRANHA PIRANHA FASTENERS PLATES RATES XTRAPLATE' XTAAPI,ATE t � FOR TUB OFF OPTIONS REFER TO NEW CONSTRUCTION ABOVE. •Refer to Carlisle's Sure-Weld Design Criteria Portion For current Code Approvals and Warranties,visit Carlisle's website, of the Current Specification or contact a Design Analyst. • ROOFING CAVM�EIRII�C ' OVER 40 YEARS AND 10 BILLION SQUARE FEETTM VOO V11\ILC</ CPO. hnTselncolpon Bd ._..._._._�_._... — , P 0.am 710D•Cadislo,PA 17013 www.carlisle-syntec.COM Fax: 17Meti445- 7143457000 Carlisle SynTec Incorporated m rket®symaaftemm Mech/ I ' CARLISLE'S © SUM=WELWM The Sure-Weld Mechanically- • Sure-Weld's reflectivity values exceed other beat-welded membranes Fastened Roofing System now •Membranes are eco-friendlyas they do not contain chlorine or plasticizers offers wider membrane •Sure-Weld's top-ply surface is thicker and smoother than other membranes n the market,providing options. 6', 81, 10' and 12'. better welding results and reduced dirt pickup System Codes Project Information •UL Class A,B and Universal Slope ratings are available This Sure-Weld Roofing System is being installed for the project named over any deck type below: •FM Uplift values up to 135 psf can be achieved job name: . For code specifics,refer to Carlisle's SW Code Approval Guide. city: Quality Assurance Carlisle Authorized Roofing Contractors have received training to install State: Carlisle's Sure-Weld Roofing Systems. The Carlisle Authorized Roofing Contractor is: Inspection company name: Upon installation completion,and prior to the issuance of a membrane address: system warranty, an inspection will be conducted by a Carlisle Technical Representative. city: state: Warmly • Consult your roofing contractor or Carlisle Manufacturer's zip: Representative/Distributor for associated warranty charges. phone: This system,properly installed and Inspected on a commercial project may receive: Installation •A 5-or 10-year Membrane System Warranty;peak gust wind Carlisle's Sure-Weld Mechanically-Fastened Roofing System utilizes speed coverage up to 55 mph whim,gray or tan membranes in standard reinforced 45-or 60-mil •A 10-year Total System or 15-year Golden Seal Warranty may be thickness or 72-or 80-call thick reinforced Sure-Weld EXTRA'". requested when all materials used for the roofing installation are. manufactured or marketed by Carlisle Insulation Is mechanically Festened to an acceptable roof deck Sure-Weld •A 20-year Golden Seal Warranty is available with Sure-Weld's membrane sheets are mechanically fastened to the deck with Carlisle HPX 72-and 80-mil EXTRA TPO membranes or HP70ra Fasteners and appropriate Piranha Plates.Adjoining sheets are •Higher wind speed warranties(up to 100 mph peak gust wind overlapped and joined together with a minimum IV wide hot an weld speed)available upon review by Carlisle The above Information represents a typical Carlisle Sure Weld •A 10-year Reflectivity Warranty(based on ENERGY STAR*criteria) available in white membrane Mechanically-Fastened Roofing System.Refer to Carlisle's published •A 10-, 15-,20-year Puncture Warranty with Sure-Weld 72-80-mil specifications and details for more complete information. Sure-Weld Membrane Strengths For more specifics or for International warranty programs, contact • Sure-Weld membrane Is availabC in white,gray and tan; Carlisle. 6'-,8'-, 10'-and 12'-widths •When tested for puncture resistance,Sure-Weld results were better than competitive heat weldable membranes (PVC and Nil — y�� SUOL Hypalon) • Because Sure-Weld's reEectMtyvalues exceed industry standards,the membrane meets the criteria for the EPA's and DOE's ENERGY STAR*Program • RROOFINGAMERIAOVER 40 YEARS AND 10 BILLION SQUARE FEEL. WWII SunV81d,FAST AAeSM REPRINT - T CODE800-4-SVNRIEC m WWBtmff=¢ REPRINT"SWMF System SuOmNIal StrxR'-642565 7.04 www.carlisle-syniec.COM ENERGY STAR Baneg61medtrddemn, 02005CMaleSynTmInmmnit8d CorllsleSynTecincorporated oxned W IN US Po'+emmenl. Pdmed In USA. TECHNICAL DATA BULLETIN CARLISLE SYNTEC INCORPORATED CARLISLE SURE-WELD® REINFORCED TPO MEMBRANE • (Standard and HS) GENERAL: Sure-Weld membrane is a heat-weldable single-ply thermoplastic polyolefin (TPO) sheet designed for new roof construction and reroofing applications. Sure-Weld HS membrane is formulated with additional flame retardant (compared to Standard) for higher slope fire code approvals. Sure-Weld membrane is based on advanced polymerization technology that combines the durability and weatherability of ethylene-propylene (EP) rubber with the heat weldability of polypropylene. The membrane is specifically formulated for long-term weather resistance without the use of either polymeric or liquid plasticizers. Physical properties of the membrane are enhanced by a strong, polyester fabric that is encapsulated between the TPO based top and bottom plies. The combination of the fabric and TPO plies provide Sure-Weld reinforced membranes with high breaking strength, tearing strength and puncture resistance. The relatively smooth surface of Sure-Weld membrane produces a total surface fusion weld that creates a consistent, watertight monolithic roof assembly. Sure-Weld Standard and HS products are available in white (highly reflective), tan and gray 45-mil and 60-mil nominal thicknesses. (See Sure-Weld EXTRA bulletin for 72-mil and 80-mil thicknesses). Special colors are also available and Carlisle can duplicate most paint colors with a 6-8 week lead time. Available widths are 4, 5 and 6 ft perimeter sheets and 8, 10 and 12 ft field sheets. The membrane is environmentally friendly and safe to install. • Carlisle's Sure-Weld tan and white TPO membranes are LEED"" (Leadership in Energy and Environmental Design) compliant. The U.S. Green Building Council (USGBC) designed the LEED Green Building Rating System. Tan and white Sure-Weld are ENERGY STAR® and California Title.24 rated roof products. Reinforced Sure-Weld membrane is also available in 6" widths for use as reinforced flashing. This product is typically used for stripping in rows of fasteners and plates or to complete butt splices on FleeceBACK® TPO membrane systems. FEATURES: • Wide window of weldability • Outstanding puncture resistance • Chlorine-free with no halogenated flame retardants • Plasticizer-free, does not contain liquid or polymeric plasticizers • Excellent low temperature impact resistance • Excellent chemical resistance to acids, bases, and restaurant exhaust emissions • Exceptional resistance to solar UV, ozone, and oxidation • Low water vapor permeance and water absorption • Hot melt extrusion processed for complete scrim encapsulation • Warp knitted fabric (not woven) for smooth surface and greater thickness-over-scrim • Polyester reinforcing fabric which is resistant to degradation by bacteria, mildew and fungi • • Consistent color with Special Colors available • Sure-Weld is 100% recyclable (refer to Carlisle's Recyclability Statement) (Pagel of 5) TYPICAL PROPERTIES AND CHARACTERISTICS: See table that is attached for basic properties and supplemental section on page 4. Typical weights are 0.23 lb/ft 2(1.1 kg/m 2) for 45-mil and 0.29 lb/ft 2 (1.4 kg/m 2) for 60-mil membrane. • CAUTIONS AND WARNINGS: - Sunglasses which filter out ultraviolet light are strongly recommended since tan and white surfaces are highly reflective to sunlight. Roofing technicians should dress appropriately and wear sunscreen to protect skin from the sun. - Surfaces may promote slippery conditions due to frost and ice build-up. Exercise caution during cold conditions to prevent falls. - Care must be exercised when working close to a roof edge when surrounding area is snow covered as the roof edge may not be clearly visible. - Use proper stacking procedures to ensure sufficient stability of the rolls. - Exercise caution when walking on wet membrane. Membranes may be slippery when wet. - Store Sure-Weld membrane in the original undisturbed plastic wrap in a cool, shaded area and cover with light-colored, breathable, waterproof tarpaulins. Sure-Weld membrane that has been exposed to the weather for approximately 7 days or longer must be prepared with Weathered Membrane Cleaner prior to hot air welding. INSTALLATION: Sure-Weld Roofing Systems are fast to install since minimal labor and few components are required. The systems may be installed utilizing labor-saving devices that make sheet welding fast, clean, • consistent, and easy to learn, while reducing strain on the roofing technician. The Carlisle Mechanically-Fastened Roof System installation starts with the insulation fastened with a minimum of 5 fasteners per 4 by 8 ft. board. The Sure-Weld reinforced membrane is mechanically fastened to the deck using HP-XTM Fasteners and Piranha PlatesTm or HP-XTRA Fasteners and Piranha XTRA Plates. Adjoining sheets of Sure-Weld membrane are overlapped over the fasteners and plates and joined together with a minimum 1-1/2 inch(4 cm)wide hot air weld. The Carlisle Fully-Adhered Roofing System application begins with the insulation fastened at the required density (max.1 every 2 sq ft) necessary to resist the appropriate wind load. The substrate and membrane are coated with Sure-Weld Bonding Adhesive and the membrane is rolled into place. Contact your Carlisle Manufacturer's Representative for the specific design requirements and installation procedures for these two systems. Carlisle, Sure-Weld,FleeceBACK,Piranha Plates and HP-X are Carlisle trademarks ENERGY STAR is a registered trademark owned by the US Government LEED is a trademark of the U.S. Green Building Council © 2007 Carlisle Construction Materials • Printed in USA 5/07F (Page 2 of 5) SURE-WELDS 45 & 60-MIL THICK REINFORCED TPO SHEET BASIC PROPERTIES AND CHARACTERISTICS (Standard and HS) • Physical Property Test Property Of Property After Method Unaged Sheet ASTM D573 aging' 28 days 240 IF Tolerance on nominal thickness,% ASTM D751 t 10 Thickness over scrim,in.(mm) ASTM D6878 typical 45-mil Optical Method 0.018(0.457) t 10% 60-mil (avg.of 3 areas) 0.024(0.610) t 10% 225(1.0)min.45-mil 225(1.0)min.45-mil Breaking strength,Ibf(kN) ASTM D751 320(1.4)typical 45-mil 320(1.4)typical 45-mil Grab Method 250(1.1)min.60-mil 250(LI)min.60-mil 360(1.6)typical 60-mil 360(1.6)typical 60-mil Elongation at break of fabric % ASTM D751 25 typical 25 typical Tearing strength,lbf(l)8 by 8 in. ASTM D751 55(245)min. 55(245)min. specimen B Tongue Tear 130(578)typical 130(578)typical Brittleness point,OF(°C) ASTM D2137 -40(-40)max. -50 -46typical Linear Dimensional Change(shrinkage),% ASTM D1204 +/-0.5 max. After 6 hours at 158 OF 70°C 0.2 typical Ozone resistance, 100 pphm, 168 hours ASTM D1149 No cracks No cracks • Resistance to water absorption ASTM D471 4.0 max. After 7 days immersion 158 OF (70°C) (top surface only) 2.0 typical Chane in mass % Resistance to microbial surface growth, ASTM D3274 9-10 typical ratio 1 is very poor, 10 is nogrowth) 2 yr S.Florida Field seam strength,Ibf/in. (kN/m) ASTM D1876 25(4.4)min. Seam tested in peel 60 10.5typical Water vapor permeance,Perms ASTM E96 0.10 max. 0.05 typical Puncture resistance,Ibf(kN) FTM 101C 250(1.1)min.45-mil (see supplemental section for additional Method 2031 325(1.4)typical 45-mil puncture data) 300(1.3)min.60-mil 350(1.6)typical 60-mil Resistance to xenon-arc weathering z ASTM G155 No cracks Xenon-Arc, 17,640 kJ/m2 total radiant 0.70 W/m' No loss of breaking exposure,visual condition at 10X 80°C B.P.T. or tearing strength Aging conditions are 28 days at 240 OF(116°C)equivalent to 400 days at 176 OF(80°C)for breaking strength, elongation,tearing strength,ozone and puncture resistance 'Approximately equivalent to 14,000 hours exposure at 0.35 W/m'irradiance B.P.T.is black panel temperature 5/07 • (Page 3 of 5) SUPPLEMENTAL APPROVALS,STATEMENTS AND CHARACTERISTICS: 1. Sure-Weld TPO meets or exceeds the requirements of ASTM D68781 Standard Specification for • Thermoplastic Polyolefin Based Sheet Roofing 2. Radiative Properties for ENERGY STAR®, Cool Roof Rating Council (CRRC) and LEEDTM TEST MET130D WRMI E TAN GRAY TPO TPO TPO ENERGY STAR initial solar reflectance Solar Spectrum Reflectometer 0.87 0.68 n/a ENERGY STAR solar reflectance after 3 years Solar Spectrum Reflectometer 0.83 0.64 n/a after cleanin CRRC initial solar reflectance ASTM C1549 0.79 0.71 0.46 CRRC solar reflectance after 3 years ASTM C 1549 uncleaned 0.70 pending I pendin CRRC initial thermal emittance ASTM C1371 0.90 0.86 0.90 CRRC thermal emittance after 3 years ASTM C1371 uncleaned 0.86 pending pending LEED thermal emittance ASTM E408 0.95 0.95 0.95 SRI Solar Reflectance Index ASTM E1980 110 88 55 An ENERGY STAR compliant low slope roof product must have an initial solar reflectance of at least 0.65 and a 3 year aged solar reflectance of at least 0.50. Cleaning of the aged roof surface is permitted by the ENERGY STAR test protocol. The Cool Roof Rating Council (CRRC) does not specify minimums for reflectance or emittance but they do require specific protocols for testing and reporting. Cleaning of the aged roof • surface is not permitted for determination of radiative properties after 3 years. A LEED "point' may be earned if a roof material is ENERGY STAR qualified and has a thermal emittance of at least 0.90 as determined by ASTM E408. California Title 24 requires an initial minimum reflectance of 0.70 and emittance of 0.75 as determined by CRRC test protocol. Solar Reflectance Index (SRI) is calculated per ASTM E 1980. The SRI is a measure of the roofs ability to reject solar heat, as shown by a small temperature rise. It is defined so that a standard black (reflectance 0.05, emittance 0.90) is 0 and a standard white (reflectance 0.80, emittance 0.90) is 100. Materials with the highest SRI values are the coolest choices for roofing. Due to the way SRI is defined,particularly hot materials can even take slightly negative values, and particularly cool materials can even exceed 100. For additional information on Carlisle products and ENERGY STAR, CRRC, LEED and California Title 24 see www.carlisle-svntec.com and select Guide to Building Green. Copyright© ASTM International, 100 Barr Harbor Drive,West Conshohocken, PA 19428-2959, USA • (Page 4 of 5) SUPPLEMENTAL APPROVALS, STATEMENTS AND CHARACTERISTICS (continued): 3. Sure-Weld TPO membranes conform to requirements of the U.S.E.P.A. Toxic Leachate Test • (40 CFR part 136)performed by an independent analytical laboratory. 4. Sure-Weld reinforced TPO was tested for dynamic puncture resistance per ASTM D5635-04 using the most recently modified impact head. 45-mil was watertight after an impact energy of 12.5 J(9.2 ft-lbf) and 60-mil was watertight after 22.5 J(16.6 ft-lbf) • (Page 5 of 5) Building Department City Of Cupertino 10300 Torre Avenue Cupertino, CA 95014-3255 U P E RT I N O Telephone: 408-777-3228 Fax: 408-777-3333 CONTRACTOR / SUBCONTRACTOR LIST JOB ADDRESS: p PERMIT# S OWNER'S NAME: PHONE# GENERAL CONTRACTOR: BUSINESS LICENSE# ADDRESS: CITY/ZIPCODE: *Our municipal code requires all businesses working in the city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY ECTION(S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SU�BC CTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: Signature Date Please check applicable subcontractors and complete the following information: SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring/ Carpeting Linoleum /Wood Glass / Glazing Heating Insulation Landscaping Lathing Masonry Painting/ Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile Owner/Contractor Signature Date