Loading...
08070188 • •Ip CITY OF CUPERTINO � %x;--*. .+a .�+:;»tom` �` " • ":' - • BUILDING DIVISION - • PERMIT COI�ITZtAGTOR IN.FUIRNTT.t T_I.O ; BUILDING DRESS: PERMITNO. 1.1145 CHARSAN LN R H BATHROOM REMODELING 08070188 • OWNER'S NAME: - PERMIT ISSUE DATE LEE HIRSCH 20149 THOMPSON RD 07/28/2008 a NE: SANITARY NO. CONTROL NO. (408) 354-1911 • ARCHITECT/ENGINEER: BUILDING PERMIT INFO ' BLDG ELECT PLUMB MECH 3rej LICENSED CONTRACTOR'S DECLARATION O O O O id I hereby affirm that I am licensed under provisions of Chapter 9(commencing Job Description i withSection 7000)ofDividon3ofthe Business and �•ProfeuionsCode. jasmyhcens is RMDL BTHRM, • 141SQ, RPLC FXTRS LIKE4LIKE EXTNG LOC n.�N N full Cie W eff{q /.��rt.,Z7 2 t License CI !3 s�z� Lle.0 y� NOTE: CONTRACTOR R H CUSTOM RMODELING PD #23649 9e�'�' Dau �7�/^,CRCHContractor ITECTS DECLARATION US�'Pt7 /�f�/BUS LIC 5/11/8 u I understand my plans shall be used as public records a g G Licensed Professional "' 3 OWNER-BUILDER DECLARATION i -..E 1 hereby affirm that I am exempt from the ctor's License Law for the i O O following reason.(Section 7031.5.Business and Professions Code:Any city or county 3 t` which requires a permit to construct alter,improve.demolish.or repair any annum Z y prior to its issuance,riser requires the applicant for such permit to file a signed statement < that heislicensdpursuant tothe provisioto of the Contractor's LiceneLaw(Chaper9 Sq.Ft. Floor Area Valuation tFP,$ (commencing with Section 7000)MDivision3ofthe Businessand Professions Code)or $15000 - that lie Is exempt therefrom and the basis for the alleged exemption.Any vloladon of Section 70314 by any applicant for a permit subjects the applicant to a civil penalty ofppm Number Occas ane T not molt than five hundred dollars(x500). 36210049 ATV P Y YPe 0 I.as owner of the property,or my employees with wages as their sole compensation. will do the work,and the structure b not Intended or offered for sale(Sec.7044.Business and Professions Cade:The Contractor's License Law does not apply to an owner or . Required Inspections property who builds or improves thereon,and who does such work himself or through his awn employees provided that such improvements are not intended angered for sale R. • however,the building or Improvement is sold within one year of completion,the owner- builder will have the burden of proving that he did not build or Improve for purpose of sale.). • 0 I.as owner of the property.am exclusively contracting with licensed contractors to couuan the project(See.7044.Business and Professions Cade:)The Cootramor's U. • cense Law does not apply to an owner of property who builds or improves thereon.and. who contracts for such projects with a contractor(S)licensed pursuant to the Contractor's • License Law. 0 I em exempt under Sec ,B&P C for this reason Owner Dau WORKER'S COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: • I ham and will=Main*Cerif roof Consent to self-insure for Worker's Cowmen- sadon,as provided for by Section 3700 of the Labor Code.for the performance of the work for which this permit is issued. 0 I have and will maintain Worker's Compensation Insurance,as required by Section 3700 of the Lake Code,for the performance of the work for which this permit is Weed ' My Worker's Compensation insurance Trier and Policy number are: . Cartier: 41%/4).—"e.. .Fd/n(.l Policy No.:: / 6 y at 4 3 . CERTIFICATE OF EXEMPTION FRO WORKERS' ' COMPENSATION INSURANCE ('this section need not be completed if the permit is for one hundred dollars(SIX) or less) • I certify that in the performance of the work for which this permit Is issued,I shall not employ any person in any manner e as to become subject to the Workers'Compensation ' Laws of California.Date Applicant NOTICE TO APPLICANT:If,after making this Certificate of Exemption,you should become subject to the Worker's Compensation provisions of the Labor Cede,you must 0 Z forthwith comply with such provisions or this permit shall be deemed revoked. Z H CONSTRUCTION LENDING AGENCY [-v1 hereby affirm that there is a construction lending agency for the performance of • X ,7 the work for which this permit is issued(Sec.3097,Civ.C.) W Q Lender's Name 7z lender's Address . C)0 I certify that I have rod this application and sue that the above information is Ip,u cortin.I agree W comply with all city and county orinances and state laws relating to 0 rV^ building comtnution.and hereby authorise representatives of this city to enter upon the W ahove-menuoned property for inspection purposes pr (We)agree to eve,indemnify and keep harmless the City of Cupertino against J Ter liabilities.judgments.eons and expenses which may in any way accrue against said City —n UZ in conseqrseoes of the granting of this permit. f ^� APPLICANT UNDERSTANDS AND WILL COMPLY WITH ALL NON-POINT Issued by: I. 4n,APP// /Date 7-2,1-,1 t.. SOURCE 71.1 TIONS [> r � W7T/o ' Re-roofs Signature of Applicant/Contractor Dare HAZARDOUS MATERIALS DISCLOSURE Type of Roof Will the applicant or future building occupant gore or handle hazardous material as defined by the Cupertino Municipal Code.Chapter 9.12.and the Health and Safety Code.Section 25532(.)7 LLL//y All roofs shall be inspected prior to any roofing material being installed. ❑Yrs gp No If a roof is installed without firstobtainin an inspection,I agree to remove Will the applicant or future building occupant use equipment or devices which g P -I hazardous air contaminants as defined by the Bay Area Air Quality Management all new materials for inspection. Dist ❑Yes Nraa . I have mad the hazardous materials requimmenuumkr tinnier 6.95 of the Califor- nbHcalth&SafetyCrde,Sessions 25505,25533 and 25334.1 understand that if the building ' deo not currently ham a tenant that It is my responsibility to notify the=upset of the requirements whit m tprior to issuance of a Cosificate of occupancy. trti Signature of Applicant Date ..7-try Owner or suthari>nd agent Dau' All roof coverings to be Class"4.°"or better CITY OF CUPERTINO • 3 ITEMS OF 3 PERMIT RECEIPT OPERATOR: patg COPY # : 1 Sec : Twp: Rog: Sub: Blk: Lot: APN • 36210049 . 00 DATE ISSUED • 07/28/2008 RECEIPT # • BS000005597 REFERENCE ID # . . . : 08070188 SITE ADDRESS • 11445 CHARSAN LN SUBDIVISION CITY • CUPERTINO IMPACT AREA OWNER • LEE HIRSCH ADDRESS • 11445 CHARSAN LN CITY/STATE/ZIP . . . : CUPERTINO CA, 95014-4981 • RECEIVED FROM • R H CUSTOM REMODELI CONTRACTOR • RICH..HORRON LIC # 23649 COMPANY • R H BATHROOM REMODELING ADDRESS • 20149 THOMPSON RD CITY/STATE/ZIP . . . : LOS GATOS, CA 95033 TELEPHONE • (408) 354-1911 • FEE ID UNIT QUANTITY AMOUNT PD-TO-DT THIS REC NEW BAL 1.BSEISMICR VALUATION - 15, 000 . 00 1 . 50 0 . 00 1 . 50 0 . 00 1REMRESBAT SQ FEET 140 . 00 429 . 00 0 . 00 429 . 00 0 . 00 1STPLNCK HOURS 1 . 00 122 . 00 0 . 00 122 . 00 0 . 00 TOTAL PERMIT : 552 . 50 0 . 00 552 . 50 0 . 00 METHOD OF PAYMENT AMOUNT REFERENCE NUMBER CHECK 552 . 50 #10022 TOTAL RECEIPT : 552 . 50 • • CITY OF CUPERTINO ADDITION/REMODEL • • CUPERTINO PERMIT APPLICATION FORM APN # Date: X62/ 1,uAM, co '7/2gfaR Building Address: 4,4v //</V/S - Gh g,-s / Mailing Address (if different from building address): Owner's Name: Phone# : dee j gonn,'2 1-//r3/+ x/Gr9fGqg/y Contractor: R 17 Gv5ror•-i R smaX6l t" Phone#: //0,,s. ?f2/ /et a Fax #: </oe 35-z( 2(/3 Contractor License#: 6?--oz_5-- Cupertino Cupertino Business License#: 23 6-y (' Contact: ,`,64 mirror, Phone#: Ior ' n 965--6 Fax #: x(OT 3 5-119/(5 Building Permit Info: Bldg. 9 Elect. 00 Plumb. [X] Mech. Z Hillside 9 Sob Description: Addition (adding sq footage): What is being remodeled (not including addition)? X1,9(1 (IA ON — 2412116-e rjert/re% (i, '/<e Fmf 4,'t Le 1'n eX,Snhi /ocrTr'bra 5' Remodel Includes Re-Roof: Yes 9 No 9 If yes list number of squares Remodel Includes Structural: Yes 9 No ❑ Square Footage: Addition: Porch: Deck: Garage: Detached Attached Remodel: Kitchen Bath )( MO-D1 Other Type of Construction (Usage Class): Occupancy Type: 1-A, 1-B 9 II/IIUV-A 9 IUIII B, IV-HT, V-B n 2 Valuation: j' S 000 Please check this box if the project is a second-story addition 9 Project Size: Express Standard 9 Large 9 Major❑ Please complete relevant portion of the Green Building Irhecklist & attach it to the application or if applicable, Green Building Points Achieved: include in plan set & the sheet index. ***For Office Use Only*** Over-the-Counter 9 Revised 7/01/08 CITY OF CUPERTINO ADDITION/REMODEL CUPEIJTINO FEE SCHEDULE • Quantity Fee ID Fee Description Fee Group Permit Type Sq Ft ADDITIONS 1R3SFDADD PLLONGRNGR Long Range PL Planning/Residential 1R3INSP Dwellings Inspections • B 1R3PLNCK ' Dwellings plan check B ' 1R3REPINSP Dwellings Repeat B Inspection 1R3REPPLNC Dwellings Repeat Plan B Check 1R3HINSP • Dwellings Hillside B inspection 1R3HPLNCK Dwellings Hillside plan B check 1R3HREINSP Dwellings Hillside B Repeat Inspection • 1R3HREPLNC Dwellings Hillside B Repeat Plan Check 1 R3ALTINSP Dwellings Alternate B Materials Inspection 1R3ALTPLNC Dwellings Alternate B Materials Plan Check 1PCESS Cesspool P 1PPRSEWG Ea. Private Sewage P Disposal System IPRSEWER Sewers P I BPSPRINK Lawn Sprinkler/Backflow , P 1BPWSVCS Main Water Service P IBSEISMICRE SeismicResidential B DECKS 1R3SFDADD OR 1R3SFDREM 1DECKWOOD Deck (Wood)-Each B (Each) S 1DECKRAIL Deck Railing-Each B (Each) • • CITY OF CUPERTINO ADDITON/REMODEL FEE SCHEDULE Quantity Fee ID Fee Description Fee Group Permit Type Sq Ft GARAGES 1R3SFDADD OR DETACHED 1R3SFDREM 1GARDTW<=1K Wood Frame up to B 1,000 SF (each) 1GARDTM<=1K Masonry up to 1,000 SF B (each) BCONSTAXR Construction Tax Res (new detached garage) PATIO'S OPEN 1R3SFDADD OR 1R3SFDREM 1 PATIOWOOD Wood Frame up to 300 B SF 1PATIOMETAL Metal Frame up to 300 B SF , 1PATIOOTHER Other Frame up to 300 SF B PATIO'S CLOSED 1R3SFDADD OR • & SUN ROOMS 1R3SFDREM 1 PATIOENCLW Enclosed Wood up to 300 B SF 1PATIOENCLM Enclosed Metal up to 300 B SF 1 PATIOENCLO Other Enclosed Patio up B to 300 SF I COVPORCH ' Porch Covered-Each B (Each) REMODELS 1R3SFDREM IREMRESKIT Kitchen Remodel up to B (Deduct"$"for ea plan 300 SF check) `�D 1 REMRESBAT Bath Remodel up to 300 B « / SF 1REMREOTH Other Remodel up to 300 B « SF • 1REMRES2 Remodel Residential B Greater than 1000 sq ft • IREMRES3 Remodel Residential B Greater than 2500 sq ft. • 3 of 3 • CITY OF CUPERTINO ADDITON/REMODEL FEE SCHEDULE • Quantity Fee ID Fee Description Fee Group Permit Type Sq Ft REMODEL PLNCK /• 1 STPLNCK(1-3 for Standard Plan Check B NOT FOR OVER THE ( remodel) - COUNTER PLAN CKS. 1REROOFRES Residential Re-roof Each B 100 SF WINDOW/SLIDING 1R3SFDREM GLASS DOOR 1 WINREP Replacement windows B (ea 8 windows) 1WINNEWNSTR New Window (non- B structural) 1 WINMEWSTR New Window (Structural B Shear Wall/Masonry) 1 WINBAYSTR Bay Window (Structural) B SKYLIGHTS 1R3SFDREM • 1SKYL<10 SF Skylight less than 10 sf B 1 SKYL>10SF Skylight greater than 10 B sf or structural 1STAIRS Stairs-first flight/ea addt'l B 1EPERMITFEE Electrical Permit Fee E 1MPERMITFEE Mechanical Permit Fee M 1PPERMITFEE Plumbing Permit Fee P 1ELCPLNCK Stand Alone Electric Pln E Ck (hourly) 1MECPLNCK Stand Alone Mechanical M Pln Ck (hourly • 1PLMPLNCK Stand Alone Plumbing P Pln Ck(hourly) 4of3 CITY OF CUPERTINO ADDITON/REMODEL FEE SCHEDULE Quantity Fee ID Fee Description Fee Group Permit Type Sq Ft 1BSEISMICRE Seismic Residential B 1TRAVDOC Travel & Documentation B IBUSLIC Business License B • • • 5 of 3 • ' Green Building Plan Check Index of Green Building Points/Categories • • . Category Example of an Index or Table of Green Plan Sheet or Page Points Building Points Categories that must be shown and referenced on the Project _ Plans See below ?'-'7 r.' -1 :';7:4'9 �iK•fr 7. M-6r tu�v,..-7` ^:.:17 -{"q1';57:":-;::.-. i., . Tr r: B. Site 9. Install H.E. Irrigation, (details/spec) L-1 2 points 11. Permeable Paving, (Nate) L-1 2 points _ C. Foundation 1. Use 15 % Flyash Concrete, (note) S-1 5 points D. Structural 3. Uses Wood I-Joist, (See Spec.) S-2 2 points 5. Use Truss with heels, (detail) 5-2 2 points 6. B. OSB Sheathing, (detail)_ S-2 . 2 paints - E. Ext. Finish 1. Composite Decking, (Nate/Spec.) A-3 2 points 4. 8. Fiber Cement Siding, (Note/Spec.) A-4 2 points F. Plumbing 1. Insulate all H.W. pipes, (Note/Spec.) P-1 2 points 5. Tankless W.H., (Note/Spec.) A-2 2 points 11. A 2500 Gal.Tank, (Note/Spec) 1.-0 10 points G. Electrical 4. E. Ceiling Fans, (Note/Spec.) A-3 4 points H. Appliances 1. Energy Star Dishwasher, (Note/Spec.) A3 1 point 3. Energy Star Refrigerator, (Note/Spec.) A-3 1 point P. Other 1. List Green Features on Plans A-1 1 paint ,`< �2,3.c ' - ':. _ TOTAL POINTS 40 points • • • Plan Review Process Work Book Page-12-Revised 3/25/08 . Green Points Rating System for Remodeling Projects • Due to the diversity of remodeling project types,assigning a"total points°value to a project to be considered environmentally friendly is not feasible. However,25 measures have been highlighted to signify that every effort should be made to incorporate them into your projects. These items have been chosen based upon their impact on the environment and the health of the home in coordination with ease of implementation and relative low cost. These measures can be used as a starting point for'greening°your project. INPUT Resources Energy IAO/Health .Site 1.Recycle Job Site Construction&Demolition Waste • j 65%=1 point;75%= 2 points;B0%=4points up to 4 Resource pts 0 i2.Salvage Reusable Building Materials is P 4 Resource-- ---- — ------ y=yes 0 3.Remodel for Mixed Use,Adaptive Reuse,and Historic Preservation 4 Resource pts y=yes 0 • 4.Protect Native Soil 2 Resource pts y=yes 0 5.Minimize Disruption of Existing Plants&Trees 1 Resource pt y=yes 0 6.Implement Construction Site Stormwater Practices 2 Resource pts y=yes 0 7.Protect Water Quality with Landscape Design 2 Resource pts y=yes 0 I8.Design Resource-Efficient Landscapes and Gardens _ J! 4 Resource pts y=yes 0 9.Reuse Materials/Use Recycled Content Materials for Landscape Areas 2 Resource pts y=yes 0 10.Install High-Efficiency Irrigation Systems 2 Resource pts y=yes 0 11.Provide for On-Site Water Catchment/Retention 2 Resource pts y=yes 0 0 0 0 B.Foundation 1.Incorporate Recycled Flyash in Concrete • 25%Recycled Flyash=2 points;Add 1 point for every 10%' increase of flyash,up to 5 points up to 5 Resource pts 0 2.Use Recycled Content Aggregate 2 Resource pts y=yes— 0 3.Insulate Foundation/Slab before backfill 3 Energy pts y=yes 0 0 0 0 C.Structural Frame il.Substitute Solid Sawn Lumber with Engineered Lumber J 3 Resource pts y=yes 0 2.Use FSC Certified Wood for framing (For every 10%of FSC lumber used=2 points,up to 10) up to 10 Resource pts. 0 3.Use Wood I-Joists for Floors and Ceilings 2 Resource pts y=yes 0 4.Use Web Floor Trusses 2 Resource pts y=yes 0 5.Design Energy Heels on Trusses 6"or more 2 Energy pts y=yes 0 6.Use Finger-Jointed Studs for Vertical Applications 2 Resource pts y=yes 0 7.Use Engineered Studs for Vertical Applications 2 Resource pts y=yes 0 8.Use Recycled Content Steel Studs for Interior Framing 2 Resource pts y=yes 0 9.Use Structural Insulated Panels(SIPS) a.Floors 3 Ener b.Wall Energy pts y=yes 0 3 Energy pts y=yes 0 c.Roof 3 Energy pts y=yes 0 10.Apply Advanced Framing Techniques 4 Resource pts y=yes 0 11.Use Reclaimed Lumber for Non Structural Applications 3 Resource pts y=yes 0 12.Use OSB — . - . . _ - - -I a.Subfloors I • b.Sheathing — 1 Resource pt y=yes 0 1 Resource pt y=yes 0 0 0 0 • INPUT Resources Energy IAO/Health D.Exterior inish • Use Sustainable Decking M aterialsials a.Recycled content 3 Resource pts y=yes 0 • 1 b.FSC Certified Wood 3 Resource pts y=yes 0 2.Use Treated Wood That Does Not Contain Chromium/Arsenic t IAG/Health pt y=yes 0 3.Install House Wrap under Siding 1 IAO/Health pt y=yes 0 4.Use Fiber-Cement Siding Materials 1 Resource pt y=yes 0 —— — 0 0 0 E.Plumbing F.Install Water Heater Jacket '1 1 Energy pt y=yes 0 2.Insulate Hot and Cold Water Pipes 2 Energy pts y=yes 0 3.Retrofit all Faucets and Showerheads with Flow Reducers a.Faucets(1 point each,up to 2 points) 1 Up to 2 Resource pts. 0 b.Showerheads(1 point each,up to 2 points) Up to 2 Resource pts. 0 4.Replace Toilest with Ultra-Low Flush Toilets I (1 point each,up to 3 points) ! Up to 3 Resource pts. 0 5.Install Chlorine Filter on Showerhead 1 IAG/Health pt y=yes 0 6.Convert Gas to Tankless Water Heater 4 Energy pts y=yes 0 7.Install Water Filtration Units at Faucets (2 points each,up to 4 points) Up to 4 IAG/Health pts. 0 8.Install On-Demand Hot Water Circulation Pump 4 Resource pts y=yes 0 U U U r.electrical 1.Install Compact Fluorescent Light Bulbs(CFLs) ,I, (6 bulbs=2 points,10 bulbs=3 points,12 bulbs=4 points) J Up to 4 Energy pts. 0 • 2.Install IC-AT Recessed Fixtures with CFLs(1 point each,up to • 5 points) Up to 5 Energy pts. 0 3.Install Lighting Controls(1 point per fixture,up to 4 points) Up to 4 Energy pts. 0 4.Install High Efficiency Ceiling Fans with CFLs (1 point each,up to 4 points) Up to 4 Energy pts. 0 U 0 0 G.Appliances 1.Install Energy Star Dishwasher 1 1 Energy pt y=yes— 0 2.Install Washing Machine with Water and Energy • •Conservation Features 1 Energy pt y=yes- 0 3.Install Energy Star Refrigerator 1 1 Energy pt y=yes— 0 4.Install Built-In Recycling Center i 3 Resource pts y=yes_ 0 - - -- • U 0 0 H.Insulation • 1.Upgrade Insulation to Exceed Title 24 Requirements a.walls 2 Energy pts y=yes 0 b.Ceilings 2 Energy pts y=yes 0 2.Install Floor Insulation over Crawl Space 4 Energy pts y=yes 0 (3.Insfall'Reaycled-Content,Fiberglass Insulation with - . LNo Added Formaldehyde i 3 IAG/Health pts y=yes 0 4.Use Advanced Infiltration Reduction Practices 2 Energy pts y=yes 0 5.Use Cellulose Insulation a.Walls 4 Resource pts y=yes 0 b.Ceilings 4 Resource pts y=yes 0 • 6.Alternative Insulation Products(Cotton,spray-foam) a.Walls 4 Resource pts y=yes 0 o.ceilings 4 Resource pts y=yes 0 0 0 0 • INPUT Resources Energy IAO/Health .1 widows i1.Install Energy-Efficient Windows • ! a.Double-Paned 1 Energy pt y=yes • 0 b.Low-Emissivity(Low-E) 2 Energy pts y=yes 0 L c.Low.Conductivity Frames 2 Energy pts y=yes 0 2.Iriitill Low Heat Transmission Glazing 1 Energy pt y=yes 0 0 0 0 J.Heating Ventilation and Air Conditioning 111.Use Duct Mastic on AM Duct Joints I 2 Energy pts y=yes 0 2.Install Ductwork within Conditioned Space 3 Energy pts y=yes 0 3.Vent Range Hood to the Outside 1 IAO/Health pt y=yes 0 4.Clean all Ducts Before Occupancy 2 IAQ/Health pts y=yes 0 5.Install Solar Attic Fan 2 Energy pts y=yes 0 6.Install Attic Ventilation Systems 1 Energy pt y=yes 0 7.Install Whole House Fan 4 Energy pts y=yes • 0 8.Install Sealed Combustion Units a.Furnaces 3 IAQ/Health pts y=yes 0 • b.Water Heaters 3 IAQ/Health pts y=yes 0 9.Replace Wall-Mounted Electric and Gas Heaters with Through-the-Wall Heat Pumps 3 Energy pts y=yes 0 10.Install 13 SEER/11 EER or higher AC with a TXV 3 Energy pts y=yes 0 11.Install AC with Non-HCFC Refrigerants 2 Resource pts y=yes 0 12.Install 90%Annual Fuel Utilization Efficiency(AFUE)Furnace 2 Energy pts y=yes 0 13.Retrofit Wood Burning Fireplaces „ a.Install EPA certified wood stoveslnserts 1 IAQ/Health pt y=yes 0 b. Install/Replace Dampers 1 Energy pt y=yes 0 c.Install Airtight Doors 1 Energy pt y=yes 0 14.Install Zoned,Hydronic Radiant Heating 3 Energy pts y=yes 0 15.Install High Efficiency Filter 4lAQ/Health pts y=yes 0 16.Install Heat Recovery Ventilation Unit(HRV) 5 IAO/Health pts y=yes 0 17.Install Separate Garage Exhaust Fan 3 IAO/Health pts y=yes 0 0 0 0 K.Renewable Energy and Roofing . 1.Pre-Plumb for Solar Water Heating 4 Energy pts y=yes 0 2.Install Solar Water Heating System 10 Energy pts y=yes 0 3.Pre-Wire for Future Photovoltaic(PV)Installation 4 Energy pts y=yes 0 4.Install Photovoltaic(PV)System (1.2 kw=6 points,2.4 kw=12 points,3.6 kw=18 points) Up to 18 Energy pts 0 [6.Select Safe and Durable Roofing Materials __ 1 Resource pt y=yes 0 7.Install Radiant Barrier ' _ - __ - 3 Energy pts y=yes 0 0 0 0 L.Natural Heating and Cooling 1.Incorporate Passive Solar Heating 5 Energy pts y=yes 0 2.Install Overhangs or Awnings over South Facing Windows 3 Energy pts . y=yes 0 3.Plant Deciduous Trees on the West and South Sides 3 Energy pts y=yes 0 • 0 0 • INPUT Resources Energy IAO/Health . n•oor Air Quality and finishes !1.Use LowMO-Vbd Paint 1 IAO/Health pts y=yes 0 2.Use Low VOC,Water-Based Wood Finishes 2 IAOMealth pts y=yes 0 • 3.Use Low/No VOC Adhesives 3 IAD/Health pts y=yes 0 4.Use Salvaged Materials for Interior Finishes 3 Resource pts y=yes 0 5.Use Engineered Sheet Goods with no added Urea Formaldehyde 6IA0/Health pts y=yes 0 6.Use Exterior Grade Plywood for Interior Uses 1 IAO/Health pts y=yes 0 L Seal all Exposed Particleboard or MDF • _ 4 IAO/Health pts y=yes 0 8.Use FSC Certified Materials for Interior Finish 4 Resource pts y=yes 0 9.Use Finger-Jointed or Recycled-Content Trim 1 Resource pts y=yes - 0 10.Install Whole House Vacuum System 3 IAO/Health pts y=yes 0 0 0 0 N.Flooring 1.Select FSC Certified Wood Flooring 8 Resource pts y=yes 0 r.Use Rapidly Renewable Flooring Materials — _ 4 Resource pts y=yes 0 3.Use Recycled Content Ceramic Tiles 4 Resource pts y=yes 0 4.Install Natural Linoleum in Place of Vinyl 5 IAOMealth pts y=yes 0 5.Use Exposed Concrete as Finished Floor 4 Resource pts y=yes 0 6.Install Recycled Content Carpet with Low VOCs 4 Resource pts y=yes 0 0 0 0 • Total Points Available: 1401 1301 57 Total Points Project Received: 01 01 0 • G:datarprogslgreenbuildingguidelineshemodelersigreenpointsfmal2.12.04protected.xis •• • • • / Ng" / //1-74 n G„-70.4 t- ESo-n,-7. 'e. 11cirs1-, O � � Gfrnr�Lr>� 1 ��uS �Li , h �� ✓�„�( La 7�`�'�5 6-/ /3 sc97 i / /Ret'?0ve ,4, t.( r2e/709-ce. Pi'rvres 1"i Cd j2 er r%�O. CA �JS-Z:•.�</ l�iC, S;-r i�S I.c car,i, 1771 s ,rd/c) SY 2ce7 eurlr%lr'n9 Con r(ric.rt.)r; RH C�5Tom i7 -�Ur� �(i � Zcc � cmc vleG stsPP6tC3 Ciec /,)%mb 2.9/‘77 rZ c 0-7,-'%c:r Ai . yo F 357/ /ei /f IVO ACCORDANCE WRIf THE CM Dr A c)c 67917)3, en, `15.7)3 Clio AcG. 6 7S e ZWEERTINO CODES AND ORDINANCES )ATE 7 2-J'--o cf SIGNEDC This set of pans end specrt,cations MUSI RePlilf-x- 0�0 De kept on the j-b at a:I limas and it is un k� e"`/(14e8'J _ D4e c cif. egg A lawful to m;.;.:. —, ,,,,,,,,5„o o, a ration 42E41d'srgme without written permissi n Iron c;,‘ � eFf flece Vein t riding k3 of Cuperti . 1 `" 0 ce48/r I MC/ The ,.. c' . _ ....- n2 . icatiom Aaci+norn 31tA4 NOT be held tc pe,mit or to be ar list. ----Tit, eppiobai of the violation of any pro%rtyo� �--j "', If MO City Ordinance or Srara !filar 30. m � ,nFknr reef e It eX'Snr) IuerIn cti'�C ne stir (Ai) ( /li55 G�iu,(. �'hGFi�NrE �,be Fan rWwresenr / TG✓PCIrc >K ( 3c s c-Ir-/1r'• 1 A 1 Ss I y j,i �''/��ss�� rl�+,,cQ ! / 7)/Xti,-moist sip P((}ce e cn'^) S/ w( !/,?l✓t ry t3 /tel ✓4(Vz r 4rcr re;. ritsr 1 - ® (t)) Prec,stre Rnlrmfx 36cer/'cacti le Min./ c:rlvs cape- • (Tu I3 onLY) • • • etecr,, Lee #.( 0d 1. o-n,i, 'e. (I i'r-5 <, 0 6 4.)3, L-I'�p 02211A14( / & i ncri•e_( 7//--/hi C CA rir5 -1 66441 /Ren7c've e.9-nJ 12-eI7I79 ce PPixrvre5 1'/1 (c) er,nho, CM r G,Sty 4/ e{, SnYiS Aoc-/9i i 0,,, S I i!, Sy 2007 r3c, ain, Ce,..te_ 6c. -,y7 2H 625n,,n -&m�vf (2l, i 2cd.:o7 Gee._ •-e ter_ 2-ce7'?- >I w✓i r ,6, . l vi , tiog 357/ %tet /1 tios 6:79r-v5, c,1, "ic-03? nel 4,G. 67S 0z5" Gln _ /e7�ammu-A-`=. c\ e) e F� Q 7E�:s I ' /'� aCiRc e vNn i4•/ a �• 1 co o m U l 1, /,oc:trc�Y� t — 3 a e b z ( I N o "JJ ,— . — `l.. -9, =- coo cctt� sa = a I ZI ��� CO d m m p 2.' o 0 o ai O n 3� inFk o o < en a ^- ti Q .may ' ` O � 2C fm TT'. ° l \ - y 1, 0 .rryo T Si • �4)) D` 1 = � n � c' N- -9-- F ! �'✓ , rco; - . ,- , e - o y y x, i�4cn �_hpC:YbA 00-5s GnC-!, roc .00 = nom 1% c SmCt /` f Liedr J j17 '_i___ /lyIn/s,.�Iv1 Ren o-te ex,s 1'�5 I ` 5 h w/' oti✓.. rzi t3 1 tm 1ve. L0,4rc(' res Mr,- (i') rre iv-e g;4I(rn e 6'eerrccA /fr,n./Sc,r/vk v41 f e. /wi Ab-j03 iolljA0 � Community Development l 10300 Torre Avenue 7-:t Cupertino CA 95014 Telephone(408)777-3228 •U P E Y R F J I N 0 Fax(408) 777-3333 •l • Building Department All Cupertino building permits must meet certain conditions related to maintaining environmental quality and public peace and safety. The two most common conditions are described below. STORMWATER POLLUTION CONTROL State law requires that Cupertino, 12 other Silicon Valley cities, Santa Clara County and the Santa Clara Valley Water District control stormwater pollution. Educating local residents and businesses and enforcing stormwater pollution control laws are key parts . • of the City's compliance efforts. Stormwater pollution prevention: It's up to us In northern Santa Clara Valley, storm drains flow directly to local creeks and San Francisco Bay, with no treatment. Stormwater pollution is a serious problem for wildlife dependent on our waterways, for people living near streams and baylands, and for the local water supply. Common sources of stormwater pollution include: • Dripped oil, fuel, and antifreeze from vehicles and heavy equipment; • Construction debris, including dirt, concrete and paint; • • Landscaping runoff containing pesticides or weed killers; and • Any material dumped or spilled into streets or storm drains The property owner and the contractor share ultimate responsibility for activities occurring at a construction site and will be held responsible for any environmental damage caused by subcontractors or employees. • For more information on construction-related stormwater requirements, see the Stormwater Quality Regulations section of the City of Cupertino web site at: http://www.cupertino.orq/city qovernment/departments and offices/ environmental services COMMUNITY NOISE CONTROL • The basic noise control requirements for construction sites are as follows: • Typical construction work hours are: - Weekdays - 7 a.m. to 8 p.m. • - Weekends - 9 a.m. to 6 p.m. • Construction other than street construction is prohibited-on holidays. • Residential daytime noise levels from complaint site - 60 dBA • Nonresidential daytime noise levels from complaint site - 65 dBA • For more information on noise control, please see Chapter 10.48 of the Cupertino • • Municipal Code, which can be accessed at http://www.amlegal.com/cupertino ca/ •• • Greg Casteel • Building Official