NO PERMIT NUMBERO, Alo
.WOOD DESTROYING PESTS AND ORGANISMS INSPECTION REPORT
This is an inspection report only -- not a Notice of Completion
ADDRESS OF PROPERTY INSPECTED
'.0791
I E. ESTATES
DR.
I CUPERTINO
195014
Stamp Date
143
111/01/94
17"
TAPS TERMITE AND PEST
SPECIALISTS, INC.AAI
'IA
Affix stamp here on Board copy only
1'.O.Bux3449
E
F
LICENSED PEST CONTROL
CA 900
S
I
OPERATOR IS AN EXPERT IN
(San )Jose, (5156)
( ) 791-7722
U
e
HIS/HER FIELD. ANY QUESTIONS
RELATIVE TO THIS REPORT SHOULD
(408) 778-5904 (408) 251-8142
FAX
A
A
A
E
X
BE REFERRED TO HIMMER.
REGISTRATION N PR0227
REPORT p 9579A
STAMP p
1828926T
SCRON p
34232719
ORDERED BY:
REPORT SENT TO:
PROPERTY OWNER:
PARTY IN INTEREST:
ORIGINAL REPORT ® LIMITED REPORT 0 SUPPLEMENTAL REPORT 0 • REINSPECTION REPORT
Original
a
Stamp Date
I
N
F
S
O
F
O
D
E
F
C
E
S
GENERAL DESCRIPTION: ONE STORY SINGLE FAMILY HOUSE.
N
A
O
T
U
q
U
e
R
U
T
A
A
A
E
X
H
C
T
T
Y
W
N
G
H
E
M
P
q
T
U
L
L
L
C
E
O
W
C
E
y
5
P
E
H
E
R
E
R
O
A
O
O
O
i
U
S
R
R
W
O
O
W
O
O
O
H
W
T
Y
G
U
L
O
S
S
S
1
V
E
R
-
B
C
N
N
E
E
❑
O
T
O
R
A
E
E
E
A
INSPECTION TAG POSTED: SUBAREA
E
E
P
M
R
P
E
O
❑
❑
M
K
O
E
N
Y
E
R
E
E
O
S
OTHER INSPECTION TAGS:
A
C
T
T
R
EO
M
C
L
B
R
'T
E
E
O
T
T'
N
E
R
s
T
E
A
I
O
R
M
S
T
S
E
S
T
A
V
E
S
U
R
S'
N
T
S
E
E
S
L AKS EVIDENT See 2A
Ti _ CWATT lRl �. rnir
SHED
INSULATION NCYP
3rd ..PAGE OF STANDARD INSPECTION REPORT ON PROPERTY AT:
10791 E. ESTATES DR. CUPERTINO
BLDG. NO. STREET CITY
1828926T 11/01/1994 9579A
STAMP NO. DATE OF INSPECTION CO. REPORT NO.
SUBSTRUCTURE:
Item 1C: There are cardboard forms on two concrete piers under the house.
RECOMMENDATION: Peel off the forms as best practical. Treat that which is
impractical to remove with copper napthenate.
****** This is a Section 2 Item'******
Item 1D: There are stored articles in cellulose containers in ground contact under
this building.
RECOMMENDATION: Remove articles and containers to eliminate all ground
contact.
****** This is a Section 2 Item ******
Item IE: Some corrosion was noted on the water pipes in subarea below the kitchen.
Although no leaks were visibly evident on this date, this condition can
indicate prior or intermittant seepage.
RECOMMENDATION: This area should be checked periodically for any future
leaks that may develop. If additional information is desired the concerned
parties should consult a licensed plumber.
****** This is a Section 2 Item ******
*Item 1F: NOTE: Some wood members in the subarea have markings or emergence holes from
a type of wood boring beetle that does not reinfest finished wood. This
existed before the structure was built and no treatments are needed.
********** Information Item **********
STALL SHOWER:
Item 2A: The prescribed water test revealed the shower pan in the master bath has
ruptured, allowing water to leak into the adjacent wood framing,
RECOMMENDATION: Remove the base and all wall tile, replace any damaged wood
.within the perimeter of the shower walls. Install a new regulationpan and
all new ceramic tile properly set into a fresh, reinforced mortar backing:
Note: Bid does not include any cleaning, painting, texturing or repair of
adjacent wall or ceiling surfaces that may or may not be needed after new
tile is installed.
****** This is a Section 2 Item ******
Item 813: Storage, etc. against the garage walls were not moved during this
inspection.
RECOIMIENDATION: Owner to move all storage at least two feet away from the
walls and then we will perform further inspection. Findings will be issued
in a supplemental report.
****** Unknown Further Inspection Recommended ******
TAPS TERMITE AND PEST SPECIALISTS, INC. --- License No. PR0227
Note: The existing shower door opens inward. We cannot reinstall this unit.
The concerned parties should either install a shower curtain or an accordian
style door after the tile. work is completed.
ABUTMENTS:
Item 6A:
The "shed" is connected to the house and fence creating an earth -wood
contact.
RECOMMENDATION: Remove and omit the shed.
****** This is a Section 2 Item ******
RAGE:
Item 8A:
There are some dry stains and minor deterioration to the sheetrock wall
behind the clotheswasher. There is no evidence of any active infection
or
structural damage by fungus (rot) at this time.
RECOMI"IITIDATION: This area should be checked periodically for any future
moisture problems that may develop. Any desired cosmetic repairs should be
referred to another tradesman.
****** This is a Section 2 Item ******
Item 813: Storage, etc. against the garage walls were not moved during this
inspection.
RECOIMIENDATION: Owner to move all storage at least two feet away from the
walls and then we will perform further inspection. Findings will be issued
in a supplemental report.
****** Unknown Further Inspection Recommended ******
TAPS TERMITE AND PEST SPECIALISTS, INC. --- License No. PR0227