Loading...
08070223 CITY OF CUPERTINO >' 1 x .w �Av1. tree h^ ' > " BUILDING DrvIs3oN • PERMIT YCOI�jTRACTORIIVFORMATION BUILDING ADDRESS: PERMrr NO. 101.53 S PORTAL AVE SUNLIGHT CONCEPTS, INC . 08070223 OWNER'S NAME: PERMIT ISSUE DATE MAIIESI1 MATHUR BUTHAM 1130 WALSH AVE 07/30/2008 NE: SANITARY NO. CONTROL NO. (408) 844-0081 ARCHITECT/ENGINEER: BUILDING PERMIT INFO BLDG ELECT PLUMB MECH S o p LICENSED CON RACIDR'S DECLARATION O O O O m 1 Wcby affirm Nal I are licensed under provisions of Chapter 9(commencignlob Description wit Section 7000)of Division 3 of NC Busincts and Prafeuiuns Code,andmy licenses INSTL 4 SOLAR TUBES u in full force and drum. D LL`:j 7 C mrdcbr SUIJIIaIM f- [ONCE-P ARCHITECTS DECLARATION nei I understand my pWs shall W used u public recons JyU G H License)Pnsfessional OWNER-ex aDER DECLARATION C O f I omby affirm that I t.5 ucmPe from the Canuac Co L A n c Law for to i.p o following moon.(Section 703 L5.Business and v,toxons Code:Any city or county Lure which in had a c.and w nit.dot.slsr.improve,demolish,or repair any structure Za bar heIsienedpursua requites to isionsoffar wchFertile fiense le a Lncdsummrni f < tathci.ii gs LhS.o.7M)p(Dis provisions 3Nf ftBuinmrY d ftfl io(Chapter Sq.Ft. Floor Area Valuation F§ (commencing wit Section J000)of bonds im m the e d esse pt Pro2aions 1.6 n of $2636 — dot io u ex1.5 b daafrom and a basis far the ils,the e.empdan Any violation of Section]oils five am aced dana s( perm+n mbjaeu the.pplkant m.civil penalty of Number Occupancy Type nor mom dnav five hundmd dallies(S500L 36905016 .� ❑I,as.of the property.ar my employee it wags at each sok.,.do.. will do dm wink,and to sines.is Out intended or offered or sale(Sec.7014,Business and Pm(cI Cade:The Conmactor's Ucame law does am apply in an owner of Required Inspections property who Wildaor improves dseeon,and wodoessuch work himself.,trough his awn employees,provided that such imprev nwis are not diamond molfemd fmale.IL however.dee building or improvemet is cold within am:yeer of crospiction,dee owner. Wilder win lain dee burden of proving deal W did rot build or improve for purpose of ale). 1,as owmr o dee property,am exclusively cormsedng wit licensed cam umn m cWmdn dee project(Sec.7044,Beinw and limfesdans Cock)The Canmemses u. ccnm Taw dos not apply m an owner of property who builds or improve Lemon,and who contracts for such projects wit a con melons)licensed pursuant m to Commons Leena Tow. . 0 lameud'umdrSee .B&PCfmtiamason Owner Date WORKER'S COMPENSATION DECLARATION I bemby affirm under perud y of perjury arc of dee following declawimu: I bow and will maintain.CudOaaofComent es ulf-iswm ferWorkers Compen. .tion,as provided for by Sudors 370111 to labor Code.for to perform..of to work for which tis permit is issued. ❑I have and win maintain Workers Compeuation Insurance.u mquiroci by Section 3700 of to Labor Code,for me Performance of to work for which not permit u issued. My Walkers Compensation haaame artier and Policy number are: Came,.. S'tA-f%- f ta-s0 Polity No.: 18114-I S CERTIFICATE OF EXEMPTION FROM WORKERS' COMPENSATION INSURANCE . (Thu s¢tlra aced notbecampleed if to permit is Iaonc hundred dollars(1100) nee l try - I certify tat in the perfarmaue of Ve worst,for which tis Permit Is issued.l shall not employ any peso..in any mamume,as in beomc object in the Workers'Ci mpemial. Laws of Califamla.Date Applicants NOTICE TO APPLICANT:If,after making the Cenifiea d of Faemptier,you should become object in to Wohers Compensation provisions of to lobar Code,you mus .J,z forthwith comply wit such Provisions or des permit shall W dcemcd m eacco. .zt O CONSTRUCTION LENDING AGENCY [-. 1 Wroby amnm dew tem ice.emunsed.a lending agency forte Purfarmadde of C to work fm which tis permit b modest(Sec.3097,Civ.C.) W� Q Lenders Name z Lenders Addles U Q 1 cerely dun I have read Ws application and sea tat tc above information u IZ.i— correct.I agree to comply wit all tiny and county ooln ince,and sum laws miming to � building construction.and beroby•ahmae rep.triws of tur.ity as cote upon tc W move-mcntimed property for inspection pmpoat (We)agree In saw,indemnify and keep harmless be City of Cupertino against fa/f liabilities,judgmenu.cass and expenses which may to any way smue againsl aid City U z in consequerce of to granting of des pcmdL '••� APPLICANT UND STANDS AND WI PLY WITH ALL NON-POINT Issued by: Date SOURCE REG ONS. 60 Ink Re-roofs Sig tau Applicauvcoo r ate x.aza uSMATERIALSDISCLDSURE Type of Roof WIII Ne appl,com fuhae Wilding ecemordame mead chasaoons materiJ u defined by to Cupoti o Municipal Code.Chapter 9.12,and de Heart and Safety Gale, M5324)?M5324)?C]Y. 2 All roofs shall be inspected prior to any roofing material being installed. ❑Yes sum dee a licant or future Wilding occtr i n a. If a roof is installed without first obtainingan inspection,I agree to remove OP g W equipment or devices which P it hvdooes air conumiums as de0ncd by dee Bay A.Air Quality Management all new materials for inspection. Disuie] / P ❑Ye W I have read to bandolier maarials requimmema underChapar6.95o1de Califor- niaHealt&Safety Code,SuNons 255U5.25533 and 2x534.1 understand dem if dee Wilding does not currently Mw a tense.deat it u m mapons.1.1.Y m notify de nasupant of dee mgmicon. sew" muvbemet ' r of.CatifsamofOcc/ryaaceyyy''' Signature of Applicant Date 7 O r All roof coverings to be Class'Jq. 0 amtartredagc Da' g d'Or betted CITY OF CUPERTINO • 2. ITEMS OF 2 PERMIT RECEIPT OPERATOR: patg COPY # 1 Sec : Twp: Rng: Sub: Blk: Lot: APN . . . . . . . . : 36905016 . 00 DATE ISSUED. . . . . . . : 07/30/2008 RECEIPT #. . . . . . ... . : BS000005635 REFERENCE ID # . . . : 08070223 SITE ADDRESS . . . . . : 10153 S PORTAL AVE SUBDIVISION . . . . . . . CITY . . . . . . . . . . . . . : CUPERTINO IMPACT AREA . . . . . . . OWNER . . . . . . . . . . . . : MAHESH MATHUR BUTHAM ADDRESS 10153 S PORTAL AVE CITY/STATE/ZIP . . . : CUPERTNTO, CA 95014 RECEIVED FROM . . . . : JIM MCDONALD III CONTRACTOR . . . . . . . : JIM MCDONALD LIC # 29092 COMPANY . . . . . . . . . . : SUNLIGHT CONCEPTS, INC . ADDRESS . . . . . . . . . . : 1130 WALSH AVE CITY/STATE/ZIP . . . : SANTA CLARA, CA 95050 TELEPHONE . . . . . . . . : (408) 844-0081 • FEE ID UNIT QUANTITY AMOUNT PD-TO-DT THIS REC NEW BAL ------------- --- ------- ---------- --------- - 1.BSEISMICR VALUATION 2, 636 . 00 0 . 50 0 . 00 0 . 50 0 . 00 1SKYL<10SF EACH 1 . 00 367 . 00 0 . 00 367 . 00 0 . 00 ---------- ---------- ---------- ---------- TOTAL PERMIT 367 . 50 0 . 00 367 . 50 0 . 00 METHOD OF PAYMENT AMOUNT REFERENCE NUMBER ------------- ------ ------- CREDIT CARD 367 . 50 DISCVR --------------- TOTAL RECEIPT 367 . 50 D7 oar 3 CQ CITY OF CUPERTINO CUPEkTINO GENERAL BUILDING PERMIT APPLICATION FORM APN # / oo Date: (l/ c0 7 � So �icb8 Building Address: 10115-3 S. ho0.'rµ Ater_. Mailing Address (if different from building address): SA &r A-5 OBo vF_ Owner's Name: Phone#: N(c'Wr-sk May08 - 777-674 Contractor: ,I Phone: ko8- `zt'f- 0081 Sci�-�Iaw (f C4- vTs. jl.-. Fax: qO5 - 844- oos--� Contractor License#: g�-723p Cupertino Business License#: Z9oq L Contact: �M I,tv Phone:--7 • Fax: `tom- 84Y-60 S"F Residential Commercial Job Description: s-r-p, L't Soy-�r'TuB= r, Building Permit Info: Bldg Elect ❑ Plumb ❑ Mech ❑ Type of Construction (Usage Class): Occupancy Type: 1-A, 1-B ❑ II/IIIN-A ❑ II/III B, IV-HT, V-B L]' -� Valuation: 2-(03(. Square Footage: Project Size: Express [/]� Standard ❑ Large ❑ Major ❑ Green Building: Please complete relevant portion of the Green Building/LEED Checklist & attach it to the application or if applicable, include in plan set & the sheet index. • Points Achieved: For help, contact Build it Green at www.buildit reen.or Revised 7/01/08 aC10FCITY OF CUPERTINO CUPEI,TINO GENERAL BUILDING PERMIT APPLICATION FORM Quantity/Sf Fee ID Fee Description Fee Permit Type Group 1GENRES or 1GENCOM 1BBOILERI For the installation or relocation of ea M boiler/compressor to & including 3 horsepower, or ea absorption-sys to & incl 100,000 Btu/h (29.3 kw) 1 BBOILER2 Installation /relocation of ea M boiler/compressor over 3 horsepower to & incl 15 horsepower, or ea absorption sys over 100,000 Btu/h 1BBOILER3 Installation/relocation of ea M boiler/compressor over 15 horsepower to & incl 30 horsepower, or ea absorption sys over 500,000 Btu/h to & incl 1,000,000 Btu/h 1 BBOILER4 Installation/relocation of ea M • boiler/compressor over 30 hosepower to & incl 50 horsepower, or for ea absorption sys over 1•,000,000 Btu/h to & incl 1,750,000 Btu/h 1 BBOILER5 Installation/relocation of ea boiler or M refrigeration compressor over 50 horsepower, or ea absorption sys over 1,750,000 Btu/h 1 BAPPLOTH For ea appliance or piece of equip M regulated by this Code but not classed in other appliance categories, or for which no other fee is listed in this code. IELECINSP Other Electrical Inspections (per hour) E 1MECHINSP Other Mechanical Inspections (per M hour) 1 PLMBINSP Other Plumbing & Gas Inspections P (per hour) 1MEETINGIHR Application Meeting B • C . - CITY OF CUPERTINO CITY F GENERAL BUILDING APPLICATION CUPERTINO . FEE SCHEDULE Quantity/Sf Fee ID Fee Description Fee Permit Type Group IGENRES or 1GENCOM ACOUSTICAL REVIEW IACOUSFDW SFDWL/Duplex New B IACOUSRESAD SFDWL/Duplex-Addition/Alteration B IACOUSCOM Multi-Family/Commercial B CHIMNEY'S 1CHIMNEY Chimney B 1 CHIMNEYR Chimney Repair B FENCES Ak I FENCE>6FT Non-masonry, over 6 ft in height B 1FENCEMAS>6 Masonry, over 6 ft in height B FIREPLACES 1FIREPLMAS Fireplace Masonry B 1FIREPLFAB Fireplace Pre-Fabricated/Metal B 1 FLAGPOL>20 Flag pole (over 20 ft in height) B 1MODUSTRU Modular Structures B FOUNDATIONS IFOUNDREP Foundation Repair B j1PILECAST Pile Foundation Cast in place concrete B ILEDRIV Pile Foundation Driven (steel,pre- B stressed concrete) 3 of 5 Sam CITY OF CUPERTINO CATV°FGENERAL BUILDING APPLICATION CUPEI�TINO . FEE SCHEDULE • Quantity/Sf Fee ID Fee Description Fee Permit Type Group 1GENRES or 1GENCOM RETAINING WALL(CONCRETE OR MASONRY 1RETSTN Standard (up to 50 ft) B 1RETSP310 Special Design, 3-10' high (up to 50 `) B 1RETSP10 Special Design, over 10' high (up to B 50') 1RETCRB< Gravity/Crib Wall, 0-10'high (up to B 50 ft) 1RETCRB> Gravity/Crib Wall over 10' high (up to B 50 ft SHED-(EACH) Shed Over 120 sq ft B • SIDING 1SIDEST/BK Siding, Stone & Brick Veneer B interior/exterior 1 SIDEOTHER Siding all other B SKYLIGHTS P 1 SKYL<10 SF Skylight less than 10 sf B 1 SKYL>10SF Skylight greater than 10 sf or B structural 1STAIRS Stairs-first flight/ea addt'l B STORAGE RACKS 1 SRACKS<=8 Storage Racks 0-8' high (up to 100 sf) B 1 SRACKS>8 Storage Racks over 8' high (up to 100 B st) • 4of5 Sei CITY OF CUPERTINO CITY OF GENERAL BUILDING APPLICATION CUPEkTINO FEE SCHEDULE Quantity/Sf Fee ID Fee Description Fee Permit Type Group 1GENRES or 1GENCOM 1STUCOAP Stucco Applications (up to 400 sf) B additional stucco application 1 WINREP Replacement windows/sliding glass B door (ca 8 windows 1WINMEWSTR New Window-structural shear B wall/masonry includes plan ck fee IEPERMITFEE Electrical Permit Fee E 1 MPERMITFEE Mechanical Permit Fee M I PPERMITFEE Plumbing Permit Fee P 1 ELCPLNCK Stand Alone Electric Pln Ck (hourly) E 1 MECPLNCK Stand Alone Mechanical Pln Ck (hrly) M 1PLMBLNCK Stand Alone Plumbing Pln Ck (hrly) P 1 STPLNCK-(3 Hr Min Standard Plan Check (when no E/M/P) B ' when not over counter) hourly-stand alone 1BSEISMICR Seismic Residential B 1 BSEISMICO Seismic Commercial B 1TRAVDOC Travel & Documentation B 1BUSLIC Business LicenseIRV B 5of5 Green Building Plan Check Index of Green Building Points/Categories A. Category Example of an Index or Table of Green Plan Sheet or Page Points Building Points Categories that must be shown and referenced on the Project Plans See below B. Site 9. Install H.E. Irrigation, (details/spec)• L-1 2 points 11. Permeable Paving, Note L-1 2 oints C. Foundation 1. Use 15 % Flyash Concrete, (note) S-1 __Ipoints D. Structural 3. Uses Wood IJoist, (See Spec.) S-2 2 points 5. Use Truss with heels, (detail) S-2 2 points 6. B. OSB Sheathing, detail S-2 __?joints E. Ext. Finish 1. Composite Decking, (Note/Spec.) AJ 2 points 4. B. Fiber Cement Siding, (Note/Spec.) A-4 __?joints F. Plumbing 1. Insulate all H.W. pipes, (Note/Spec.) P-1 2 points 5. Tankless W.H., (Nota/Spec.) A-2 2 points 11. A 2500 Gal.Tank, (Note/Spec) L-1 10 oints G. Electrical 4. E. Ceiling Fans, (Note/Spec.) A-3 4 points H. Appliances 1. Energy Star Dishwasher, (Note/Spec.) A-3 1 point 3. Energy Star Refrigerator, Note/S ec. AJ 1 point P. Other 1. List Green Features on Plans A-1 -__Ipont TOTAL POINTS 40 points • Plan Review Process Work Book Page-12-Revised 325/08 Green Points Rating System for Remodeling Projects Due to the diversity of remodeling project types,assigning a'total points'value to a project to be considered environmentally friendly is . not feasible. However,25 measures have been highlighted to signify that every effort should be made to incorporate them into your projects. These items have been chosen based upon their impact on the environment and the health of the home in coordination with ease of implementation and relative low cost. These measures can be used as a starting point for"greening"your project. INPUT Resources Energy M011-lealth A, ite 1.Recycle Job Site Construction 8 Demolition Waste 65%=1 point;75%= 2 points;BO%=4 points up to 4 Resource pts 0 2.Salvage Reusable Building Materials _ J' 4 Resource pts y=yes 0 3.Remodel for Mixed Use,Adaptive Reuse,and Historic Preservation 4 Resource pts y=yes 0 4.Protect Native Soil 2 Resource pts y=yes 0 5.Minimize Disruption of Existing Plants 8 Trees 1 Resource pt y=yes 0 6.Implement Construction Site Stonnwaler Practices 2 Resource pts y=yes 0 7.Protect Water Quality with Landscape Design _ 2 Resource pts y=yes 0 li.Design Resource-Efficient Landscapes and Gardens - 4 Resource pts y=yes 0 9.Reuse Materials/Use Recycled Content Materials for Landscape Areas 2 Resource pts y=yes 0 10.Install High-Efficiency Irrigation Systems 2 Resource pts y=yes 0 11.Provide for On-Site Water Catchment/Retention 2 Resource pts y=yes 0 1 1 1 B.Foundation 1.Incorporate Recycled Flyashin Concrete . 25%Recycled Flyash=2 points;Add 1 point for every 10% increase of Byash,up to 5 points up to 5 Resource pts 0 2.Use Recycled Content Aggregate 2 Resource pts y=yes 0 3.Insulate Foundation/Slab before backfill 3 Energy pts y=yesl;;F 0 1 1 1 C.Structural Frame lLSubstitute Solid Sawn Lumber with Engineered Lumber 1 3 Resource pts y=yes 0 2.Use FSC Certified Wood for framing (For every 10%of FSC lumber used=2 points,up to 10) up to 10 Resource pts. 0 3.Use Wood -Joists for Floors and Ceilings 2 Resource pts y=yes 0 4.Use Web Floor Trusses 2 Resource pts y=yes 0 5.Design Energy Heels on Trusses 6'or more 2 Energy pts y=yes 0 6.Use Finger-Jointed Studs for Vertical Applications 2 Resource pts y=yes 0 7.Use Engineered Studs for Vertical Applications 2 Resource pts y=yes 0 6.Use Recycled Content Steel Studs for Interior Framing 2 Resource pts y=yes 0 9.Use Structural Insulated Panels(Sips) a.Floors 3 Energy pts y=yes 0 b.Wall 3 Ener is 9Y P Y=Yes 0 c.Roof 3 Energy pts y=yes p 10.Apply Advanced Framing Techniques 4 Resource pts y=yes 0 11.Use Reclaimed Lumber for Non Structural Applications 3 Resource pts y=yes 0 !T2.Use 0S8 -- -- — i a.Subfloors 1 Resource pt y=yes 0 • b.Sheathing _ _ I 1 Resource pt y=yes 0 1 1 1 INPUT Resources Energy IAQ/Health D. ztenor Fimsh (1.Use Sustainable Decking Materials a.Recycled content 3 Resource pts y=yes 0 • b.FSC Certified Wood 3 Resource pts y=yes 0 2.Use Treated Wood That Does Not Contain ChromiumlArsenic 1 IAQ/Health pt y=yes 0 3.Install House Wrap under Siding 1 IAQ/Health pt y=yes 0 �4.Use Fiber-Cement Siding Materials 1 Resource pty=yes 0 E.Plumbing 1.Install Water Heater Jacket _ l 1 Energy pt y=yes 0 2.Insulate Hot and Cold Water Pipes 2 Energy pts y=yes 0 3.Retrofit all Faucets and Showerheads with Flow Reducers a.Faucets(1 point each,up to 2 points) Up to 2 Resource pts. 0 b.Showerheads(1 point each,up to 2 points) Up to 2 Resource pts. 0 4.Replace Toilest with Ultra-Low Flush Toilets (1 point each,up to 3 points) _ Up to 3 Resource pts. 0 5.Install Chlorine Filter on Showerhead 1 IAQ/Health pt y=yes 0 6.Convert Gas to Tankless Water Heater 4 Energy pts y=yes 0 7.Install Water Filtration Units at Faucets (2 points each,up to 4 points) Up to 4 IAQ/Health pts. 0 8.Install On-Demand Hot Water Circulation Pump 4 Resource pts y=yes 0 1 1 1 1 1 r.trecmcar 1.Install Compact Fluorescent Light Bulbs(CFLs) (6 bulbs-2 points,10 bulbs=3 points,12 bulbs=4 points) _J Up to 4 Energy pts. 0 2.Install IC-AT Recessed Fixtures with CFLs(1 point each,up to • 5 points) Up to 5 Energy pts. 0 3.Install Lighting Controls(1 point per fixture,up to 4 points) Up to 4 Energy pts. 0 4.Install High Efficiency Ceiling Fans with CFLs (1 point each,up to 4 points) Up to 4 Energy pts. 0 1 1 1 G.Appliances 1.Install Energy Star Dishwasher 1 Energy pt y=yes 0 2.Install Washing Machine with Water and Energy Conservation Features 1 Energy pt y=yes 0 3.lnstall Energy Star Refrigerator 1 Energy pt y=yes 0 4.Install Built-In Recycling Center 3 Resource pts y=yes 0 H.Insulation 1.Upgrade Insulation to Exceed Title 24 Requirements a.walls 2 Energy pts y=yes 0 b.Ceilings 2 Energy pts y=yes 0 2.Install Floor Insulation over Crawl Space 4 Energy pts y=yes 0 (3.Install Recycled-Content,Fiberglasslnsulation with No Added Formaldehyde 3IAQ/Health pts y=yes 0 4.Use Advanced Infiltration Reduction Practices 2 Energy pts y=yes 0 5.Use Cellulose Insulation a.Walls 4 Resource pts y=yes 0 b.Ceilings 4 Resource pts y=yes 0 • 6.Alternative Insulation Products(Cotton,spray-foam) a.Walls 4 Resource pts y=yes 0 b.Cenrngs 4 Resource pts y=yes 0 INPUT Resources Energy IAO/Health mdows ! 1.Install Energy-Efficient Windows i • a.Double-Paned 1 Energy pt Y--yes 0 . b.Low-Emissivity(Low-E) 2 Energy pts y=yes 0 L c.Low.Conductivity Frames ___ 1 2 Ener_ 9Y pts y=Yes 0 2.Install Low Heat Transmission Glazing J 1 Energy pt y=yes 0 1 1 1 J.Heating Ventilation and Air Conditioning . 7.Use Duct Mastic on All Duct Joints 2 Energy Pls Y=Yes 0 2.Install Ductwork within Conditioned Space 3 Energy pts y=yes 0 3.Vent Range Hood to the Outside 1 IAQ/Health pt y=yes 0 4.Clean all Ducts Before Occupancy 2 IAQ/Health pts y=yes 0 5.Install Solar Attic Fan 2 Energy pts y=yes 0 6.Install Attic Ventilation Systems 1 Energy of y=yes 0 7.Install Whole House Fan 4 Energy pts y=yes 0 S.Install Sealed Combustion Units a.Furnaces 31AQ/Health pts y=yes 0 b.Water Heaters 3 IAQ/Health pts y=yes 0 9.Replace Wall-Mounted Electric and Gas Heaters with Through-the-Wall Heat Pumps 3 Energy pts y=yes 0 10.Install 13 SEER/11 EER or higher AC with a TXV 3 Energy pts y=yes 0 11.Install AC with Non-HCFC Refrigerants 2 Resource pis y=yes 0 12.Install 90%Annual Fuel Utilization Efficiency(AFUE)Furnace 2 Energy pts y=yes 0 13.Retrofit Wood Burning Fireplaces • - a.Install EPA certified wood slovesfinserts 1 IAQ/Health pt y=yes 0 b. Install/Replace Dampers 1 Energy pt y=yes 0 c.Install Airtight Doors 1 Energy pt y=yes 0 14.Install Zoned,Hydronic Radiant Heating 3 Energy pts y=yes 0 15.Install High Efficiency Filter 4 IAQ/Health pts y=yes 0 16.Install Heat Recovery Ventilation Unit(HRV) 5 IAQ/Health pts y=yes 0 17.Install Separate Garage Exhaust Fan 3 IAQ/Health pts y=yes 0 1 1 1 K.Renewable Energy and Roofing 1.Pre-Plumb for Solar Water Heating 4 Energy pts y=yes 0 2.Install Solar Water Heating System 10 Energy pts y=yes 0 3.Pre-Wire for Future Photovoltaic(PV)Installation 4 Energy pts y=yes 0 4.Install Photovoltaic(PV)System (1.2 kw=6 points,2.4 kw=12 points,3.6 kw=18 points) Up to 18 Energy pts 0 I6.Select Safe and Durable Roofing Materials —� 1 Resource pt y=yes 0 •7.Install Radiant Barrier ----- 3 Energy pts y=yes 0 1 1 1 L.Natural Heating and Cooling 1,Incorporate Passive Solar Heating 5 Energy pts y=yes p 2.Install Overhangs or Awnings over South Facing Windows 3 Energy pts , y=yes 0 3.Plant Deciduous Trees on the West and South Sides 3 Energy pts y=yes p 1 1 1 • INPLYT Resources Energy IAO/Heafth M. ndoor Au Quality and Finishes ;1.Use LowAo-TOC Paint _ _ 1 IAQ/Health pts y=yes 0 2.Use Low VOC,Water-Based Wood Finishes 2 IAQ/Health pts y=yes 0 • R.ULOW/N Ilse O VOC Adhesives _ 3 IAQ/Health pts y=yes 0 4 s --- — 4.Use Salvaged Materials for Interior Finishes 3 Resource pts y=yes 0 5.Use Engineered Sheet Goods with no added Urea Formaldehyde 61AO/Health pts y=yes 0 6.Use Exterior Grade Plywood for Interior Uses 1 IAQ/Health pts y=yes 0 L.Seal all Exposed Particleboard or MDF _ 4 IAQ/Health pts y=yes 0 8.Use FSC Certified Materials for Interior Finish 4 Resource pts y=yes 0 9.Use Finger-Jointed or Recycled-Content Trim 1 Resource pts y=yes 0 10.Install Whole House Vacuum System 3 IAQ/Health pts y=yes 0 1 1 1 N.Flooring 1,Select FSC Certified Wood Flooring 8 Resource pts y=yes 0 12.Use Rapidly Renewable Flooring Maledals _ 4 Resource pts y=yes 0 3.Use Recycled Content Ceramic Tiles 4 Resource pts y=yes 0 4.Install Natural Linoleum in Place of Vinyl 5 IAQ/Health pts y=yes 0 5.Use Exposed Concrete as Finished Floor 4 Resource pts y=yes 0 6.Install Recycled Content Carpet with Low VOCs 4 Resource pts y=yes D 1 1 Total Points Available: 1 1401 1301 57 Total Points Pro'ect R 1 01 01 0 • G:datatprogstgreenbuildingguidelines/remodelerslgreenpointsfinal2.7 2.04protected.xls • Community Development 10300 Torre Avenue fPTY Cupertino CA 95014 NFTelephone(408)777-3228 F Fax(408)777-3333 *UPERTINO Building Department JOB ADDRESS: 10153 .S poR �V� PERMIT # SG ?O2--L7 OWNER'S NAME: meg„ rr1 PHONE # 'tog -- 77- 8 % GENERAL CONTRACTOR: 5un+L.%c wr Cc»,cp rs .r.c FAX # -1og . b .t, Cb5-4- I am not using any subcontractors: *� 5-4z� Z 170&C / Signature Date Please check applicable subcontractors and complete the followinginformation: SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets &Millwork Cement Finishing Electrical Excavation Fencing Flooring: Carpeting Linoleum/ Wood • Glass / Glazing Heating Insulation Landscaping Lathing Masonry Ornamental Sheet Metal Painting/ Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile Owner/Contractor Signature Date