NO PERMIT NUMBER (2) CERTIFICATION OF RE-CLAIMED WATER SYSTEMS CROSS CONNECTION SPECIALISTS
CERTIFIED CROSS CONNECTION CONTROL CONSULTANTS A• _ BACKFLOW PREVENTION VALVE EXPERT
INSTALLATION-REPAIRS-TESTING-CERTIFICATION
BACKFLOW PREVENTION SPECIALISTS INC.
LICENSED CONTRACTOR C.C.L.#427328LIFQRNIA (800)464-FLOW(3569)
3750-E CHARTER PARK DR.,SAN JOSE CA 95136-1356 .�. � `� F`(408Y 269.2600
3608 FERNWOOD ST.,SAN MATEO CA 94403 FAX( B)269-2650
SERVICE ADDRESS 19500 Prunerid a Ave.,Cu ertino -Wolfe
MAILING ADDRESS The Hamptons CONTACT Edgar
19500 Pruneridge Ave. TEL# 873-8800
Cupertino,CA 95014
MANUFACTURER MODEL NUMBER TYPE SIZE SERIAL NUMBER
Wilkins 975XL RP 11/2" 652499
INTERNAL ❑ TAG LOCATION OF DEVICE right of carpor 1 I 1 irrigation in enclosure
EXTERNALS /
IF DEVICE IS ANEW INSTALLATION PLEASE CHECK THIS BOX PASSp FAIL❑
• REDUCED PRESSURE DEVICES PRESSURE TYPE
DOUBLE CHECK VALVES VACUUM BREAKERS
RPP VALVES DIFFERENTIAL
CHECK VALVE CHECK VALVE PRESSURE/RELIEF
N0.1 N0.2
VALVE AIR INLET CHECKVALVE
CLOS TIGHT CLOSED TIGHT OPENED AT LBS. OPENED AT_LEIS CLOSED TIGHT ❑
INITIAL #Ibe. #lbs. *LBS •LBS.
TEST OPENED UNDER 2.0 OPENED UNDER 1.0
LEAKED ❑ LEAKED ❑ OR DID NOT OPEN ❑ OR DID NOT OPEN ❑ LEAKED ❑
REPAIRS
AND
MATERIALS
USED
FINAL CLOSED TIGHT❑ CLOSED TIGHT ❑ CLOSED TIGHT❑
TEST #LBS #LBS OPENED AT_LES OPENED AT_LBS #LBS
THE ABOVE REPORT IS CERTIFIED TO BE TRUE
10220 DATE 10-26.04
INITIAL TEST BY CER
C' _ TIFIED TESTER N0.
MO. DAY YR.
. REPAIRED BY DATE
FINAL TEST BY CERTIFIED TESTER NO. DATE
MO. DAY YR.
CERTIFICATION OF RE-CLAIMED WATER SYSTEMS 8'"'"' CROSS CONNECTION SPECIALISTS
4�CERTIFIED CROSS CONNECTION CONTROL CONSULTANTS • BACKFLOW PREVENTION VALVE EXPERT`-� * INSTALLATION-REPAIRS-TESTING-CERTIFICATION ,
BACKFLOW PREVE TIMAN SPECIALISTS, INC.
LICENSED CONTRACTOR C.C.L.#427328 BY: __ _ CALIFORNIA (800)464-FLOW(3569)
3750-E CHARTER PARK DR.,SAN JOSE CA 95136-1356 ===�dOBj 269-2600
3606 FERNWOOD ST.,SAN MATEO CA 94403 FAX(408)269.2650
SERVICE ADDRESS 19500 Pruneridge Ave.,Cupertino/X-Wolfe
MAILING ADDRESS The Hamptons CONTACT Edgar
19500 Pruneridge Ave. TEL# 873-8800
Cupertino,CA 95014
MANUFACTURER MODEL NUMBER TYPE SIZE SERIAL NUMBER
Wilkins 975 RP 11/2" 595500
INTERNAL Q TAG LOCATION OF DEVICE left of basketball court irrigation in enclosure
EXTERNAL 19
IF DEVICE IS ANEW INSTALLATION PLEASE CHECK THIS BOX PASSFAIL❑
• REDUCED PRESSURE DEVICES PRESSURE TYPE
DOUBLE CHECK VALVES VACUUM BREAKERS
RPP VALVES DIFFERENTIAL
CHECK VALVE CHECK VALVE PRESSURE I RELIEF
NOAN0.2 VALVE AIR INLET CHECKVALVE
u
CLOSED TIGHT CLOSED TIGHT OPENED AT LBS. OPENED AT—LBS CLOSED TIGHT ❑
INITIAL F Iba. #IbS. #LBS #LBS.
TEST 9 ,0 OPENED UNDER 2.0 OPENED UNDER 1.0
LEAKED ❑ LEAKED ❑ OR DID NOT OPEN ❑ OR DID NOT OPEN ❑ LEAKED ❑
REPAIRS
AND
MATERIALS
USED
FINAL CLOSED TIGHT❑ CLOSED TIGHT ❑ OPENED AT LOS OPENED AT LBS CLOSED TIGHT
TEST #LBS #LBS #LBB
THE ABOVE REPORT IS CERTIFIED TO BE TRUE
INITIAL TEST BY� CERTIFIED TESTER NO. 10220 DATE 10-26-04
YY MO. DAY YR.
. REPAIRED BY DATE
FINAL TEST BY CERTIFIED TESTER NO. DATE
MO. DAY YR.
CERTIFICATION OF RE-CLAIMED WATER SYSTEMS CROSS CONNECTION SPECIALISTS
BACKFLOW PREVENTION VALVE EXPERT
CERTIFIED CROSS CONNECTION CONTROL CONSULTANTS
1 ? INSTALLATION-REPAIRS-TESTING-CERTIFICATION
P.N1Ck�;�V�.. ,�.eY�lgr�9.s•
�BACKFL IV W `PREVENTION SPECIALISTS, INC.
LICENSED Cown4UMR C.C.L.#427328 CALIFORNIA (800)464-FLOW(3569)
3750-E CHARTER -95'136-1356 (408)269.2600
3608 FERNWOOD ST.,SAN MATEO CA 94403 FAX(408)269.2650
SERVICE ADDRESS 19500 Pruneridge Ave.,Cupertino/X-Wolfe
MAILING ADDRESS The Hamptons CONTACT Edgar
19500 Pruneridge Ave. TEL# 873-8800
Cupertino,CA 95014
MANUFACTURER MODEL NUMBER TYPE SIZE SERIAL NUMBER
Wilkins 975XL RP 11/2, 532158
INTERNAL ❑ TAG LOCATION OF DEVICE prop line 40'from curb carport 21 irrigation
EXTERNAL ® in enclosure
IF DEVICE IS ANEW INSTALLATION PLEASE CHECK THIS BOX[] PAS FAIL❑
• REDUCED PRESSURE DEVICES
PRESSURE TYPE
DOUBLE CHECK VALVES VACUUM BREAKERS
RPP VALVES DIFFERENTIAL
CHECK VALVE CHECKVALVE PRESSURE I RELIEF
AIR INLET CHECK VALVE
NOA NO.2 VALVE
CLOS I�GHT CLOSED TIGHT OPENED AT LBS. OPENED AT_LBS CLOSED TIGHT ❑
INITIAL 0lbs. . LC/� f lbs. #LBS 0 LSS.
TEST OPENED UNDER 2.0 OPENED UNDER 1.0
LEAKED ❑ LEAKED ❑ OR DID NOT OPEN ❑ OR DID NOT OPEN ❑ LEAKED ❑
REPAIRS
AND
MATERIALS
USED
FINAL CLOSED TIGHT❑ CLOSED TIGHT ❑ OPENED AT_LBS OPENED AT_LBS CLOSED TIGHT El
TEST *LBS #LBS #LBS
THE ABOVE REPORT IS CERTIFIED TO BE TRUE
INITIAL TEST BY CERTIFIED TESTER NO. 10220 DATE 10-26-04
MO. DAY YR.
• REPAIRED BY DATE
FINAL TEST BY CERTIFIED TESTER NO. DATE
MO. DAY YR.
CERTIFICATION OF RE-CLAIMED WATER SYSTEMSCROSS CONNECTION SPECIALISTS
BACKFLOW PREVENTION VALVE EXPERT
CERTIFIED CROSS CONNECTION CONTROL CONSULTANTS INSTALLATION-REPAIRS-TESTING-CERTIFICATION
V 1
BACKFLOW PREVENTION SPECIALISTS, INC.
LICENSED CONTRACTOR C.C.L.#427328 CALIFORNIA (800)464-FLOW(3569)
3750-E CHARTER PARK DR.,SAN JOSE CA 95136.1356 (408)269.2600
3608 FERNWOOD ST.,SAN MATEO CA 94403 FAX(408)269.2650
SERVICE ADDRESS 19500 Pruneridge Ave.,Cupertino/ -Wolfe
NUV 0 9 2004 j
MAILING ADDRESS The Hamptons CONTACT Edgar
19500 Pruneridge Ave. Y'— _:_ 873-8800
Cupertino,CA 95014
MANUFACTURER, MODEL NUMBER TYPE SIZE SERIAL NUMBER
Wilkins 975 RP 11/2" 595894
INTERNAL ❑ TAG LOCATION OF DEVICE next to carport 146 irrigation in enclosure
EXTERNAL
IF DEVICE IS ANEW INSTALLATION PLEASE CHECK THIS BOX[3 PASSP/FAIL❑
• REDUCED PRESSURE DEVICES
PRESSURE TYPE
DOUBLE CHECK VALVES VACUUM BREAKERS
RPP VALVES DIFFERENTIAL
CHECK VALVE CHECKVALVE PRESSURE I RELIEF
NOA NO.2 VALVE AIR INLET CHECK VALVE
CLOSED TIGHT CLOSED TIGHT OPENED ATS,a LBS. OPENED AT_LBS CLOSED TIGHT ❑
INITIAL $lbs. 8 •r�- 0Ibs. #LBS M LBS.
TEST OPENED UNDER 2.0 OPENED UNDER 1.0
LEAKED ❑ LEAKED ❑ OR DID NOT OPEN ❑ OR DID NOT OPEN ❑ LEAKED ❑
REPAIRS
AND
MATERIALS
USED
FINAL CLOSED TIGHT CLOSED TIGHT ❑ OPENED AT_LBS OPENED AT LBS CLOSED TIGHT❑
TEST $LBS $LBS $LBS
THE ABOVE REPORT IS CERTIFIED TO BE TRUE
INITIAL TEST BV CERTIFIED TESTER NO. 10220 DATE 10-26-04
MO. DAY YR.
• REPAIRED BY DATE
FINAL TEST BY CERTIFIED TESTER NO. DATE
MO. DAY YR.
,