NO PERMIT NUMBER (3) CERTIFICATION OF RE-CLAIMED WATER SYSTEMS ��_ -���///,,,...... CROSS CONNECTION SPECIALISTS
CERTIFIED CROSS CONNECTION CONTROL CONSULTANTS A' BACKFLOW PREVENTION VALVE EXPERT
V . INSTALLATION-REPAIRS.TESTING-CERTIFICATION
BACKFLOW PREVENTIONSPECIALISTS, INC.
LICENSED CONTRACTOR C.C.L.#427328 CALIFORNIA (800)464-FLOW(3569)
3750-E CHARTER PARKOR:,SAN JOSE CA 95136-1356 (406)269-2600
3808 FERNWOOD ST.,SAN MATEO CA 94403
FAX(408)269-2650 E ' ' iVFD
{ Nov 1 3 2003
SERVICE ADDRESS 19500 Ptuneridge Ave.,Ctrl ttino/X-Wolfe
MAILING ADDRESS T_ e Hamptons CONTACT EdgBY'
19500PnmeridgeAve. TEL# 873-8800
Cupertino,CA 95014CA 95014
MANUFACTURER MODEL NUMBER TYPE SIZE SERIAL NUMBER
Wilkins 975 RP 11/2" 595894
INTERNAL ❑ TAG LOCATION OF DEVICE next to Carport 146 irrigation in enclosure
EXTERNAL
1F DEVICE IS A NEW INSTALLATION PLEASE CHECK THIS BOX❑ PASS FAIL❑ .
• en ._._...._... REDUCED-PRESSURE DEVICES
PRESSURE TYPEr ,z
DOUBLE CHECK VALVES -- - VACUUM BREAKERS -
RPP VALVES DIFFERENTIALCHECK VALVE CHECK VALVE PRESSURE I RELIEF
N0.1 -,. N0.2
VALVE AIR INLET CHECK VALVE
CLOSED TLGHT CLOSED TIGHT-'- OPENED AT-.._LBS. OPENED AT_LBS CLOSED TIGHT ❑
INITIAL #lbs._ __-_ p lbs. #LBS #LBS,
TEST OPENED UNDER 2.0 OPENED UNDER 1.0
I� LEAKED LEAKED nOR DID NOT O�P1EN OR DID NOT OPEN Cl LEAKED ❑
REPAIRS Kep/Q(Ed P I /gCID RVIOr-44
MATERIALS 1 Ce`lC�ll DIY,``^^ L"Ct� RU"/UP/� y{�I
USED �l CC O�'IX iN pralI(Ye/�
q
It,
FINAL CLOSED GHT CLOSED TIGHT• i' CLOSED TIGHT❑
,_. 7p� OPEN DA '/
TEST #LBS �• A #LBS E T_LBS OPENED AT_LBS #LBS i
THE ABOVE REPORT IS CERTIFIED TO BE TRUE - --
r
I NITIAL TEST -- - CERTIFIED TESTER NO. - .:DATE.,11-07-03
BY���-.�..V`. . . 9815
,.MO. DAY YR.'
REPAIRED BY . : t ', .,.i . . . ... ....... .
FINAL TEST BY CERTIFIED TESTER NO. DATE
MO. DAY YR.
o„
CERTIFICATION OF RE-CLAIMED WATER SYSTEMS CROSS CONNECTION SPECIALISTS
BACKFLOW PREVENTION VALVE EXPERT
CERTIFIED CROSS CONNECTION CONTROL CONSULTANTS _,'
, INSTALLATION-REPAIRS-TESTING-CERTIFICATION
%ACKFLOW PREVENTION SPECIALIST ST ED .
LICENSED CONTRACTOR C.C.L.#427328 CALIFORNIA (f Py FLOW(356
3750-E CHARTER PARK DR.,SAN JOSE CA 95136-1356 (408)269-800 NOV 1 3 2003
3608 FERNWOOD ST.,SAN MATEO CA 94403
SERVICE ADDRESS 19500 Pmneridge Ave.,500 Pmneridge AveCu�rtino/X-Wolfe BY•-Wolfe BY•----
MAILING ADDRESS The Hamptons CONTACT Edgar
19500 Pnrneridge Ave. TEL# 873-8800
Cupertino,CA 95014CA 95014
MANUFACTURER MODEL NUMBER TYPE SIZE SERIAL NUMBER
Wilkins 975XL RP 11/2° 532158
INTERNAL ❑ TAG LOCATION OF DEVICE prop line 40'from curb carport 21 irrigation
EXTERNAL ® in enclosure '
IF DEVICE IS ANEW INSTALLATION PLEASE CHECK THIS BOX PASS® FAIL❑
• REDUCED PRESSURE DEVICES
PRESSURE TYPE
DOUBLE CHECK VALVES VACUUM BREAKERS
RPP VALVES DIFFERENTIAL
CHECK VALVE CHECK VALVE PRESSURE/RELIEF
N0.1 N0.2
VALVE AIR INLET CHECK VALVE
CLOSED TIGHT ❑ CLOSED TIGHT ❑ OPENEOAT_LBS. OPENEDAT_LBS CLOSED TIGHT ❑
INITIAL 0Ibs. #Ibs. #LBS #LBS.
TEST OPENED UNDER 2.0 OPENED UNDER 1.0
n,, LEAKED /a,l n LEAKED IpA OR DID NOT OPEN OR DID NOT OPEN ❑ LEAKED ❑
REPAIRS Inc ALG P,,IO,,C`r� K v4jq C.el Rp'QCe&
AND '41 CrlRl� )&
��."C/�eLC CN�C�IQ
MATERIALS
USED VAI U 9-
FINAL
FINAL CLOS–ErD TIGHT CLOSED TIGHT a k CLOSED TIGHT❑
TEST 0 HIS / • ALBS OPENED AT_LBS OPENED AT_LBS #LBS
THE ABOVE REPORT IS CERTIFIED TO BE TRUE
I NITIAL TEST BY —CERTIFIED TESTER N0. 9815 DATE 11-07-03
MO. DAY YR.
• REPAIRED BY DATE
FINAL TEST BY CERTIFIED TESTER NO. DATE
MO. DAY YR.