Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
02110087
CITY OF CUPERTINO - amLnlnc DlvlspoN PEA1 'I` CONTRe�.GTUR INFU 3UN � . Bm9P(MSP9REs8AN FELIPE RD GEORGE FLAMMER PERMITNO2110087 ow6NOR15E FLAMMER A1PLICATP7spgD3Y2002 40 ZONE: - SANITARY NO. CONTROL NO. ARCHITECDENGINEER: BUILDING PERMITINFO BLDG ELECT PLUMB MECH 0 0 0 0 p00 LICENSED COroRACfOR'SDECLARATION Job De rl t100 m F 1 hereby affirm Net I am licensed under pmvisians of Chapter 9(commencing RAD I 0 ANTENNA ...000CCC P G� withSectinn]fgln)of Division 3of NeBusinexand Professions Code,and mylicense is / —Py� F SSS Lifullcolaend affect. `'Tye y'Y S qiceZ Lnse Clpes Lre.N OZ— DateContractor F= ARCHITECTS DECLARATION 0 e U 1 understand my plans Nill be ux0 u public rtords Et 0� Licensed PoKeminnul OWNER-BUILDER nexempt DECLARATION a r Z I hereby.(Gran Nat 11. exempts an the Comranoo License c law for the $38 6 6 0 0 which Mason.it Permit n 703 1.5.Business and Pe.de o Li Code:Any tiny structure m'Z� which requires•permit re teres dic altee,improve,dcarrit' m repair any euueturo v-Z pdormslimm issuance,atu require Novisio sof foeweh Peron mElee,Law(sutemem pp O (that he commesccgwithSnuamroNepmviviosnodue oftheBlnaohndProessw(Codo)or 391I2B12[O"AfL® Valuation K (cat heI,ttemi@Section]Bndth Dlvision 3or ofaleged Business and Professions Any Cade)or — that he is 31.5 b Nem from and the.perm for thebj alleged exemption.Any violation of Sktiohadmin byany applicant riSSMpermit subjects the applicant to acivil Penalty of PNN Occupancy e Ki, nm Nan five nunared aallan(ssoB). P Y Ty'P uowner of the property.or my employee with wges pe Neu sole ministrations 102 — PIERS 444d doth.work and she stracture is not intended or offered for We(Sm.7014,Butinei rand Profusions Code:The Conlrecrors Lianse Law does not apply to an owner of 104 - REBAR Required Inspections property who burl&or improve thereon,and who doessoch work himselfor through his ownerno.,m,provided thatsuch!top rovemem;art not rnmndedoroRered forsda If, 105 — ANCHOR BOLTS however,the building or improvement is mid within one year of completion,the owner, builder will have the burden of praying that he did not Wild or improve for purpose of 106 - SEWER & WATER mk')' 202 - UNDERFLOOR PLUMBING 141.a owner of the property,am exclusively tsmunt with lravW mnvmmn to 203 — UNDERFLOOR MECHANICAL conformal the project(Sec.7044,Basin a fesiov Code:)The Conuactoh Li cents law em pplyman owner ofp pe ywhobuildaori-pimmsthereoaane 204 - UNDERFLOOR FRAME whoconwe n hpmjectswiNaco en IicenudpursuantrotheContnnorb' - 205 — UNDERFLOOR INSULATION Lkenx Le ❑ IuReg In der Sea BgPC(orthis mpeon 301 - ROUGH PLUMBING TV awn< ex e ' . Da. - TUB & OR SHOWER w Ea•sc ENSATIonD RATION 303 — ROUGH MECHANICAL Iharedyndw under pensfior ofuryoaorNemllowrngdeclara0onso 304 - ROUGH ELECTRICAL 1 hers end will maintain econd37Certificate of Covent toCode,for for Workert Compete Who.u provided for by Section 7]00 of the labor Code,for Ne pertarmance of the 305 - FRAME work lar which Nix Permit ta issued. 306 — HOLDOWNS ❑I lass and will maintain Worksrs Compensation Ivurantt,v required by Semon 3 7 — INSULATION 3]00 of the labor Code,far thc pcfromuch ofthe work for which this permit is ipeved. 307 — INSULATION My Workers Compensation Insurance carrier and Policy number art: SHEETROCK Carrier: Policy No: 309 - EXTERIOR LATH CERTIFICATE WORKERS' COMPENSATION INSURANCE 310 — INTERIOR LATH Thisseclian rad nm be completed if Ne permb isforom hundred dollars(SIM) 311 - SCRATCH COAT f`la`x') 313 - ROOF NAIL 1 certify than in the performance of the work for which this permit is issued,1 Nell not 501 - FINAL ELECTRICAL ENERGY employ any person in any houracrm as m becomeu subject the Workers Compensation Laws of California.Dale 502 - FINAL PLUMBING ENERGY Applicant NOTICE TO APPLICANT.Ir,after making this Cmdricatc of Exemption,you should 503 - FINAL MECHANICAL ENERGY a become subjecttothcworker'sCompensationProvisionsoftheLaborCode,youmost 504 - FINAL BUILDING ENERGY OZ forthwith comply with such provisions or this penal,shall W damcd revoked. CONSTRUCTION LENDING AGENCY 505 — FINAL ELECTRICAL Iherebyeff uthaLlh to is a construction lending agency for the arrormenauf 506 - GAS TEST 6! Ncwork for which this permitisIssued(See.3097,Civ.C.) 507 - FINAL PLUMBING W Q Lendcr'a Namc 0. Z Ie Z'.Add. 508 - FINAL MECHANICAL U O 1 unify Nat 1 have mail this;application antistatic that the shove information n 509 - FINAL GRADE U. F. cnrrealagree incomply with all city and county ordinances and sudelaws rehtingin 5 FINAL PLANNING O building conswetion.and hominy auNodx representatives of this city be enter upon Ne strove-mcnowned pmperty for inspection purposes (We)agree In save,indemnify and krm lump halem the City of Cupenino against 14 FIN RKS LIC WO py liabilities,judgments,costs and expenses which may in any way acerae against mid City U 7 in consequence of the granting Of this permiL t� APPLICANT UNDERSTANDS AND WILL COMPLY WITH ALL NON-POINT Issued by: Date SOURCE REGULATIONS. Re-roofs Signature ofApplicantfContraotor Dem HAZARDOUS MATERIALS DISCLOSURE Type Of ROOF Will Ne applicant or future Municipal Cg Occupant atria or handle hazardous material v defined Section Ne Cupertino Municipal Code,Chapter 9.12.and the Health and Safety Code. 35372(x)1 Oy. ONO All roofs shall be inspected prior to any roofing material being installed. ❑Ye Will the applicant or future Wilding occupant too equipment or devices which If a roof is installed without first obtaining an inspection,I agree to remove mit hazardous air contaminants as defined by the Bay Area Air Quellny Management all new materials for inspection. District? ❑Yet ONO 1 have read Ne hanNnus materials requirements under Chapter 6.95 ofthc Cahfimr fie Health&Safety Cute,Secuov 35505,35533 and 35534.1 Link suM dust if Na Wilding does not currently have a tenant.that in is my¢xponsibiiity to notify use occupant of Ne requirements which most he met prior inmumm,ofaCmirateofOccupen, Signature of Applicant Date Owner m indforizcd a gent Dane All roof coverings to be Class "B" or better CITY OF CUPERTINO CITY OZ. Uo � CUPEI� TPERMIT APPLICATION FORM INO APN# Date: S` z 2 Zo8� 3 A/O✓ ZooZ Building Address: SA+v �¢/.'PE Owner's Name: Phone #: .to Contractor: License#: Contact: Phone#: Applicant/Contractor: Fax #: ing Permit Info: Bldg Elect Plumb Mech JZb'Ue–scription: Residential: Commercial: Sq.Ft.Floor Area: $/Sq.Ft.: Architect/Engineer: Valuation: p ©o Type of Construction: Occupancy Group: , D Quantity Fee ID Fee Description Fee Group BAPPLOTHER OthWA—ppliances MECHANICAL BCONSTAX Construction Tax BUILDING BCONSTAX Ind/Off/Comm/Quasi BUILDING BCONSTAXBQ Con. Tax for BQ Zone BUILDING BCONSTAXH Hotel and Motel BUILDING BCONSTAXR Constax–Resi/Mobile BUILDING BELEC1000 Elec 600V <= 1000A ELECTRICAL BELEC1001 Elec 600V> 1000A ELECTRICAL BELEC200 Elec Svcs 600V<= 200A ELECTRICAL BENERGY Energy BUILDING 13ENERGYADD Energy Add Multi BUILDING BINVESTIGA Investigation fee BUILDING BMITIGATC Comm. Housing Mit. Fee BUILDING BMITIGATR Res. Housing Mit Fee BUILDING BMNEWMULTI New Multi-Family Res MECHANICAL BNEWMULTI New Multi-family Res ELECTRICAL BNUCOMME New Comm Electric ELECTRICAL BNUCOMMM New Comm Mechanical MECHANICAL BNUCOMMP New Comm Plumb PLUMBING 1 of 2 ()3 73 PURPOSE AND USE • The purpose of this letter is to provide background and installation information regarding a 'I permissible antenna support structure (the tower) being installed at 10549 San Felipe Rd. Cupertino, CA 95014, for use with a federally licensed amateur radio station and show this installation to be in full compliance with City of Cupertino Municipal Code Chapter 19.108. The use of these antennas and supporting tower is exclusively for amateur radio operations(also known as HAM radio). The station is operated within the FCC part 97 rules. The station is used for low-power hobby type communications that include both local contacts and global contacts that bolster international good will. There are a number of drawings that will help to visualize the proposed changes. The wind load analysis has been included to show that careful consideration to engineering and safety are of paramount concern. LOCATION CONSIDERATIONS The following items were considered in locating the antennas and support structure: 1) Ensure that any support structure failure will not cause the antenna or the structure to touch power lines. 2) Ensure that any support structure failure will result in minimal risk to normally occupied areas of the yard. . 3) Locate the structure close to the operating position of the station to minimize feed line length. 4) Use the house to strategically distribute tower loads to minimize the size and number of required guy wires and guy supports in order to maximize aesthetics. In this installation, no - guy wires are utilized. DESIGN CONSIDERATIONS NOV 513 2002 J The following items were considered in designing the antenna support structure: By 1) Sustained winds above 90 mph will cause antenna and mast bending failures that will lighten the tower wind load to reduce the chance of a catastrophic tower failure. Winter conditions in this area are not conducive to ice build-up. No ice loading was factored into the design for load analysis. 2) Supports have been designed so that removal of these items, in the event that the house is sold, will not leave any"eye-sores"to contend with. 3) The height was chosen with several factors in mind. r���� v� ECyrD BsIIJJ JJ 3 02- a) To be below the height which would require City of Cupertino permitting/variance., b) To comply with FAA height. �- -Dr T. PLANNI c) To comply with FCC height restrictions without special permission (200 feret).fE/�(3 George Flammer Page 1 11/3/2002 Aaetma(varteaa) Antenna meat 1.5'dA r In approximately 1.5 s9•R 2 length(above tamer peak) • wlntlbatl. � n 7 Antenna mart 7 Olen Martin RT-939 Roof Top Tower (9'55 pound aluminum tower) 3 (straddling roof anrt) 8' O C� IF ff • p • NOV 13 2002 v 3. Southern Elevation View Total: 28' Flammer Residence 10549 San Felipe Rd. Cupertino,CA 95014 Figure 1 -Side Elevation View. In this drawing, the tower structure is shown to comply with City of Cupertino Municipal Code Chapter 19.108.050 Section C Paragraph 1 • George Flammer Page 2 11/3/2002 • 6010118 ]M'a5' Bola Beano read boll Ord InasoN O Olen Martin RT-036 Roof Top Tower (9'66 pound aluminum tower.) Made of rugged 6061-TO angle aluminum with stainlesssteel hardware.ware. House roof line(not to sonle). r aaw.bmr tlMlloMYlb rµiTNAgLrb m• r.~eeaaae *" ONggaMrqaabqeq ORdRbNOMMlgtb Figure 2-Tower mounting design (detail). N0� 13 2002 BY- J • George F/ammer Page 3 11/3/2002 • LOAD ANALYSIS OF AMATEUR RADIO ANTENNA SYSTEM AND SUPPORT STRUCTURE FOR 10549 San Felipe Rd. ABSTRACT The stress loading herein uses the "method of joints"type of analysis and is presented in load as pounds of force in bending moment.All joints are considered simple single point cantilevers and use conventional load polarities in terms of tension and compression and are expressed as foot pounds. Only first order load distribution is used to ensure an adequate over design and also to ensure that the supporting members are not stressed beyond their modulus of elasticity (maximum allowable load). ASSUMPTIONS AND FACTORS Below is a list of assumptions and factors used in this analysis. 1) The antenna manufacturers' load ratings are accurate and true. 2) Failures are wind related and antennae failure will occur first. 3) The design consideration is 80 mph wind loading. • 5) The area is subject to no ice build up during the winter. 8) Use EIA wind loading of 20 pounds/square ft. of rated antenna area for 80 mph. CRITICAL LOAD MEMBER DEFINITIONS Load members are identified on the drawing as having an [n]designation, whereas, "n" is a number identifier. Below is a description and area value of each critical load member. oa 1 -Area = 1.5 square ft. as typical anticipated wind loading value of directional rglenna!r I 2-Area = 0.1 square ft.wind loading of 2'exposed mast and elevation rotator. NOV 13 2002 3-Area = 1.5 square ft.wind loading of Glen Martin RT-938 roof mount tower. By CRITICAL LOAD POINT DEFINITIONS Critical load points were determined as point of failures of the antenna support structure and do not preclude the failure of the antennas. Load points are identified on the drawing as having an {x)designation, whereas, "x"is an alphabetic letter identifier. Below is a description each critical load point. A-The points where the roof mounted tripod are attached to the roof. • B-The point where the mast engages the supporting tower. George Flammer Page 4 11/3/2002 C -The point where anticipated antenna is mounted to the vertical mast. D—Center point of the wind load represented by the Glen Martin RT-938 tower itself. • LOADING 1) Determine static load for each load member at design wind load of 80 mph. SL(n)= square ft of(n)'20 SL(1)= 1.5'20= 30.0 SL{2) =0.1 '20= 2.0 SL{3)= 1.5'20= 30.0 2) Determine bending moment at point(A)for each load member. SM(n)_ (SL{n)'length in feet from A) + SL(n). SM(1)= 30.0' 10.0= 300.0+ 30.0= 330.0 SM(2)= 2.0' 10.0= 20.0 +2.0= 22.0 SM(3)= 30.3= 90.0+ 30.0= 120.0 (assume CG @ T) 3) Determine final bending moment(since we assume there will be no ice loading) bending • moment at point(B). FM(A)= SM(1)+ SM{2)+ SM(3) FM(A)= 330.0+ 22.0+ 120.0 = 472.0 4) Determine maximum bending moment at points{A,...4). FM(A,)= FM(A)/4 FM(A,)=472.0/4= 118.0 (3 in tension, 1 in compression) [pi'n-el V 1CONCLUSION Both compressive and tensile loads are well within design limits for 2as installed per Figure 2.. Souce: Southern Pine Council: Maximum Spans for Southem Pine Joists& Rafters, 5/93. Southern Pine Inspection Bureau: Standard Grading Rules for Southern Pine Lumber, 1994 • Edition. And Western Wood Products Association: Westem Lumber Size-Adjusted Values, 2/92, and Westem Lumber Span Tables, 2/94. George Flammer Page 5 11/3/2002