NO PERMIT NUMBER (5) TESTING ENGINEERS, INC. 2811 Adeline St. PO Box 24075 510 835-3142 510 834-3777 fax Oakland, CA 94608 Oakland, CA 94623 800 660-3142 Oakland Santa Clara Sacramento Diablo Valley Monterey Honolulu Work Request No.: C-1055 INSPECTION REPORT Week Ending: 10/9/92 PROJECT#31739/GRE539 TYPE OF INSPECTION: PT Concrete PROJECT.- Seven Springs P1I-9A P,'�C�.IVE.�- PLACE OF INSPECTION: Tract 8098 1,; �� 1 Jobsite Ridgecreek & Pinebrook Way Cupertino, CA CIT'( OF CU?ERTINO Permit #'s 21742, 21733, 21740 & 21711 CJILO,AO DATE 10/6/92 HOURS 8 ZONEIMILES 1 INSPECTOR(S) G. Braunle Reported to Dan Allari of The Gregory Group at the jobsite. Monitored loads arriving at the jobsite for correct mix and proper slump. Inspected placement operations and vibrating procedures. Performed 4 slump tests (415", 4", 4-3/4" and 41:") and cast 4 sets of compression test specimens(4 ea.), Sample #'s 116479, 116480, 116481 and 116482 for concrete placed at Lot 386 through 389 post-tensioning slab-on-grade and footings. (Concrete Mix#0246 from Lonestar at 3,000 psi; 4W' slump) Total yards placed: 183 Work inspected, as noted, was incompliance with approved job plans and specifications - PT-1. Reviewed by: Roger Taneley C.E. 620132, Exp. 9-30-93 Ice: The Gregory Group/Chris Gatley Bauer Concrete Pacific Post Tension Bassenian/Lagoni Archit. City of Cupertino/Bldg. Insp. Dept. TESTING ENGINEERS INC. 2811 Adeline St. PO Box 24075 510 835-3142 510 834-3777 fax Oakland, CA 94608 Oakland, CA 94623 800 660-3142 Oakland Santa Clara Sacramento Diablo Valley Monterey Honolulu Work Request No.: C-1193 INSPECTION REPORT Week Ending: 10/30/92 PROJECT#31739/GRE539 TYPE OF INSPECTION: Stressing PROJECT: Seven Springs/8/372-375 & 386-389 PLACE OF INSPECTION. 'rract8098 Jobsite Phase 9A Cupertino, CA DATE 10/26/92 HOURS 8 ZONEIMILES 1 INP T R s J. Hatfield Reported to Dan Allari of The Gregory Group at the jobsite. Inspected post-tensioning operations and measured elongations of tendons for Lots 372 through 375 and 386 through 389. Elongations were within the specified limits. Elongations are shown on the attached post-tensioning sheets. Notes: Could not verify concrete had reached required strength for stressing. The contractor will take responsibility. Work inspected, as noted, was in compliance with approved job plans and specifications. Reviewed by: Roger S. Tansley C.E. #20132, Exp. 9/30/93 Ice: The Gregory Group/Chris Gatley Bauer Concrete Pacific Post Tension Bassenian/Lagoni Archit. City of CupertinoBldg. Dept.