Loading...
BACKFLOW CERTIFICATION OF RE-CLAIMED WATER SYSTEMS CROSS CONNECTION SPECIALISTS CERTIFIED CROSS CONNECTION CONTROL CONSULTANTS BACKFLOW PREVENTION VALVE EXPERT I NSTALLATION-REPAIRS-TESTING-CERTIFICATION s -7 w %ACKFLOW PREVENTION SPECIALISTS, INC. LICENSED CONTRACTOR C.C.L.#427328 CALIFORNIA (800)4&i-FLOW(3589) 3750-E CHARTER PARK DR.,SAN JOSE CA 95136-1356 (408)269-2600 3608 FERNWOOD ST.,SAN MATEO CA 94403 FAX(408)269-26. it SERVICE ADDRESS Comer of De Anna 8t Stevens Creek,Cupertino NU V 4 _H'3 MAILING ADDRESS Robert A Bothman CONTACT G'e LJ 650 Quinn Ave TEL# 639-1313 San Jose,CA 95112 .- MANUFACTURER MODEL NUMBER TYPE SIZE SERIAL NUMBER Willdns 975XIL RP 3/4" 926686 INTERNAL ❑ TAG LOCATION OF DEVICE mtr#62024871 EXTERNAL IF DEVICE IS ANEW INSTALLATION PLEASE CHECK THIS BOX PASS FAIL❑ • " ' - - REDUCED PRESSURE DEVICES / , PRESSURE TYPE DOUBLE CHECK VALVES VACUUM BREAKERS - RPP VALVES DIFFERENTIAL CHECK VALVE CHECK VALVE PRESSURE/RELIEF NO.1 NO.2 VALVEE AIR INLET CHECK VALVE CLOSEL DT. IyHT CLOSED TIGHT OPENED AT f•VLBS. OPENEOAT_LBS CLOSEDTIGHT ❑ INITIAL #lbs.. (/J 0Ib& #LBS 0LBS. TEST OPENED UNDER 2.0 OPENED UNDER 1.0 LEAKED ❑ LEAKED ❑ OR DID NOT OPEN ❑ OR DID NOT OPEN ❑ LEAKED ❑ REPAIRS AND MATERIALS USED FINAL CLOSED TIGHT❑ CLOSED TIGHT ❑ OPENED AT_LBS OPENED AT CLOSED TIGHT❑ TEST #LBS #LBS _LBS_ $LBS THE ABOVE REPORT IS CERTIFIED TO BBEE/TRUE INITIALTESTBV C/• — - CERTIFIED TESTER NO. 9815 DATE 11-19-03 MO. DAY YR. • REPAIRED BY _ CATS FINAL TEST BY CERTIFIED TESTER NO, DATE MO. DAY YR. CERTIFICATION OF RE-CLAIMED WATER SYSTEMS CROSS CONNECTION SPECIALISTS CERTIFIED CROSS CONNECTION CONTROL CONSULTANTS BACKFLOW PREVENTION VALVE EXPERT �j INSTALLATION-REPAIRS-TESTING-CERTIFICATION %ACKFLOW PREVENTION SPECIALISTS, INC. LICENSED CONTRACTOR C.C.L.#427328 CALIFORNIA (800)464-FLOW(3569) 3750-E CHARTER PARK DR.,SAN JOSE CA 95136-1356 (408)269'2800 3608 FERNWOOD ST.,SAN MATEO CA 94403 FAX(469)269.2650 SERVICE ADDRESS Comer of De Anja&Stevens Creek Ann&Stevens Cue rtino MAILING ADDRESS Robert A Bothman CONTACT George 650 Quinn Ave TEL# 639-1313 San Jose,CA 95112 MANUFACTURER MODEL NUMBER TYPE SIZE SERIAL NUMBER Febco 825Y RP 2° AL5570 INTERNAL ❑ TAG LOCATION OF DEVICE mtr#62024871 EXTERNAL IF DEVICE IS ANEW INSTALLATION PLEASE CHECK THIS BOX[] PASSXFAIL❑ • REDUCED PRESSURE DEVICES PRESSURE TYPE DOUBLE CHECK VALVES VACUUM BREAKERS RPP VALVES DIFFERENTIAL CHECK VALVE CHECK VALVE PRESSURE I RELIEF NO.1 N0.2 VALVE AIR INLET CHECK VALVE 111,,,��� CLOSED TIGHT CLOSED TIGHT ly OPENED AT�LBS. OPENED AT_LBS CLOSED TIGHT ❑ INITIAL #Ib#. � #Ibe. , ` #LBS #LBS. TEST OPENED UNDER 2.0 OPENED UNDER 1.0 LEAKED ❑ LEAKED ❑ OR DID NOT OPEN Cl OR DID NOT OPEN ❑ LEAKED ❑ REPAIRS AND MATERIALS USED FINAL CLOSED TIGHT Cl CLOSED TIGHT Cl CLOSED TIGHT❑ TEST #LBS #LBS OPENED AT_LBS OPENED AT_LBS t LBS THE ABOVE REPORT IS CERTIFIED TO BE TRUE e INITIAL TEST BY CERTIFIED TESTER NO. 9815 DATE 11-19-03 MO. DAY YR. •REPAIRED BY DATE FINAL TEST BY CERTIFIED TESTER NO, DATE MO. DAY YR.