Loading...
01090065 Structural O / og 00 � �� FErr o 3 c,J4-1,1 , +� 42DD AVENUE ALL STF!_t-40%TURRL SANTA CLATRA.CA 95050 PHONE: (408)559-0340 CONSULTING ENGINEERS, Inc. FAX: (408)559-2015 October 2,2001 To Whom It May Concern: SUBJECT: 20687 Craig Ct.Residence Cupertino,California Dear Sir or Madam: At the contractor's request I have visited the subject property to inspect the installation of the anchor bolts for holdowns. The anchor bolts are installed using all thread rods in drilled holes with ICBO approved epoxy resin. The anchor bolts are installed according to the structural drawings,the manufacturer's specification and the structural standards. Should you have any questions or require supplemental information,please call. Sincerely, ALL STRUCTURAL CONSULTING EN I RS r�oo OGE It ((_ No.3008 Geo a Dicu,P , SE Structural Eng r , • t (page 1 of 4 � CF-6R INSTALLATION CERTIFICATE T (P g ) 'ermrt um er rte A cess An installation certificate is required to be posted at the building site or made available for all appropriate inspections. (The information provided on this form is required;however,use of this form to provide the information is optional.) After completion of final inspection,a copy must be provided to the building department(upon request)and the building owner at occupancy,per Section 10-103(b). HVAC SYSTEMS: Heating Equipment N of Efficiency Duct Duct or Heating Heating Equip. Location Piping Load Capacity Type(pkg. CEC Certif¢d Mfr Name Identical (AFUE,etc.)' D 6 ,. heat um and Model Number Systems RCF IRvaluel (attic etc) R•value (Btu/hr) (Btu/hr) Cooling Equipment 'w of Etficiena Duct Cooling Cooling Equip. CEC Certified Compressor Y Type(pkg. Unit MG Neme and Identical (SEER,etc.)' Location Duct Load Capacity heatpump) Model Number Systems RCF iRvaluel (attic eta.) R•value_ (Btu/hr) (Btu/hr) 1. >_reads greater than or equal to. 1,the undersigned,verify that equipment listed above is: 1)is the actual equipment installed,2)equivalent to or more efficient than that specified in the certificate of compliance(Form CF-1R)submitted for compliance with the Energy Efficiency Standards for residential buildings,and 3)equipment that meets or exceeds the appropriate requirements for manufactured devices(from the Appliance Efficiency Regulations or Part 6),where applicable. S ignatui e,Date Installing Subcontractor(Co.Name) OR General Contractor(Co.Name)OR Owner T R HEATING SYSTEMS: Distribution IfReeir- Nof Rated' Tank Efl)- External Heater CEC Certified Mfr Type(Std, eulation, Identical Input(kW Volume cieney' Standby' Insulation Type Name&Model Number Point-of-Use) Control Type Systems or Btu/hr) (gallons) (EF,RE) loss(%) R-value 2 For small gas storage(rated input of less than or equal to 75,000 Btu/hr),electric resistance and heat pump water heaters,list Energy Factor. For large gas storage water heaters(rated input of greater than 75,000 Btulhr),list Recovery Efficiency,Standby Loss and Rated Input. For instantaneous gas water heaters,list Recovery Efficiency and Rated Input. Faucets&Shower Heads: All faucets and showerheads installed are certified to the Commission,pursuant to Title 24,Part 6,Subchapter 2,Section I11. I,the undersigned,verify that equipment listed above my signature: 1)is the actual equipment installed;2)is equivalent to or more efficient than that specified in the certificate of compliance(Form CF-1R)submitted for compliance with the Energy Efficiency Standards for residential buildings;and 3)the equipment meets or exceeds the appropriate requirements for manufactured devices(from the Appliance Efficiency Regulations or Part 6),where applicable. ignature, ate Installing Subcontractor(Co.Name)OR General Contractor(Co.Name)OR Owner COPY TO: Building Department Building Owner at Occupancy Revised March 1,1996 INSTALLATION CERTIFICATE (page 2 of 4) CF-6R rte A rens crmrt um er Fc N FSTRATION/GLAZING; Manufactured Operator Products Type(e.g.. Labeled Site Built Products Total I11-value(5 A of Default Quantity Square Commenu/ Manufacturer/Brond Nome slider) CFIRvalue)t Pan" U-Veluet (Optional) Feet Special Features (GROUP LIKE PRODUCTS) 1c 2. 3. 4. 5. 6. 7. 8. 9. 10. I I. 12. 13. -- 14. 15. t Installed U-value must be less than or equal to value from CF-IR. Alternatively,installed weighted average U-value for the total fenestration area is less than or equal to value from CF-IR. 1,the undersigned,verify that the fenestration/glazing listed above my signature: 1)is the actual fenestration product installed;2)is equivalent to or more efficient than that specified in the certificate of compliance(Form CF-IR)submitted for compliance with the Energy Efficiency Standards for residential buildings;and 3)the product meets or exceeds the appropriate requirements for manufactured devices(from Part 6),where applicable. Item#s Pgn-atlure,Date Installing Subcontractor(Co.Name)OR (if applicable) General Contractor(Co.Name)OR Owner Item#s Signature,Date Installing Subcontractor(Co.Name)OR (if applicable) General Contractor(Co.Name)OR Owner Item#s Signature,Date Installing Subcontractor(Co.Name)OR IreIte General Contractor(Co.Name)OR Owner (ifapplicable) COPY TO: Building Department '�• Building Owner at Occupancy Revised March 1,1996 INSTALLATION CERTIFICATE (page 3 of 4) CF-6R The following is an explanation of many of the input values required on this form: HVA SYSTEMS Heating Equipment Type must be one of the following: Furnace: Gas or oil-fired central furnace&space heater Boiler: Gas or oil-fired boiler PckgHeatPump: Packaged central heat pump SplitHeatPump: Split central heat pump RoomHeatPump: Room heat pump LgPkgHeatPump: Large packaged heat pump(>_65,000 Btu/hr output) Electric: Electric resistance heating(fixed HSPF=3.413);radiant electric resistance (fixed HSPF=3.55) CombinedHydro: Reference water heater under water heating systems below CEC Certified Manufacturer Name&Model Number from applicable Commission approved appliance directory. 0 of Identical Systems is for those systems with the same efficiency,duct location,duct R-value and capacity. Efficiency from applicable Commission certified appliance directory. Duct Location is attic,crawl space,CVC crawl space,conditioned space,unconditioned space(piping)or none. Duct(or Piping)R-Value from Directory of Certified Insulation Materials and/or manufacturer's data. Heating/Cooling Load refer to Commission approved load calculation procedure. Heating/Cooling Capacity from the applicable Commission certified appliance directory. Note: location elevations over 2,000 ft above sea level require a derating of output capacity(refer to manufacturer's literature). Cooling Equipment Type must be one of the following: SplitAirCond: Split system air conditioner PckgAirCond: Packaged air conditioner Split Heat Pump: Split system heat pump PckgHeatPump: Packaged heat pump RoomHeatPump: Room heat pump LgPkgHeatPump: Large packaged heat pump(e-65,000 BftAr output). Substitute EER for SEER when SEER is not available RoomAirCond: Room air conditioner. Minimum SEER varies* LgPkgAirCond: Large packaged air conditioner(2 65,000 Btu/hr output). Substitute EER for SEER when SEER is not available EvapDirect: Direct evaporative cooling system. For compliance calculation purpo^.es, fixed values: SEER=11.0;duct location=attic;duct insulati.m R-value= 4.2 Evapindirect: Indirect evaporative cooling system. For compliance calculation purposes, fixed values: SEER=13.0;duct location a attic;duct insulation R-value II 4.2 •Refer to Commission publication Appliance Efficiency Regulations,P400-92-029 Revised March 1,1996 INSTALLATION CERTIFICATE (page 3 of 4) CF-6R rhe following is an explanation of many of the input values required on this forth: HVAC SYSTEMS Heating Equipment Type must be one of the following: Furnace: Gas or oil-fired central furnace&space heater Boiler: Gas or oil-fired boiler PckgHeatPump: Packaged central heat pump SplitHeatPump: Split central heat pump RoomHeatPump: Room heat pump LgPkgHeatPump: Large packaged heat pump(Z 65,000 Btu/hr output) Electric: Electric resistance heating(fixed HSPF=3.413);radiant electric resistance (fixed HSPF=3.55) CombinedHydro: Reference water heater under water heating systems below CEC Certified Manufacturer Name&Model Number from applicable Commission approved appliance directory. #of Identical Systems is for those systems with the same efficiency,duct location,duct R-value and capacity. Efficiency from applicable Commission certified appliance directory. Duct Location is attic,crawl space,CVC crawl space,conditioned space,unconditioned space(piping)or none. Duct(or Piping)R-Value from Directory of Certified Insulation Materials and/or manufacturer's data. Heating/Cooling Load refer to Commission approved load calculation procedure. Heating/Cooling Capacity from the applicable Commission certified appliance directory. Note: location elevations over 2,000 ft above sea level require a derating of output capacity(refer to manufacturer's literature). Cooling Equipment Type must be one of the following: SplitAirCond; Split system air conditioner PckgAirCond: Packaged air conditioner Split Heat Pump: Split system heat pump PckgHeatPump: Packaged heat pump RoomHeatPump: Room heat pump LgPkgHeatPump: Large packaged heat pump(z 65,000 Btu/hr output). Substitute EER for SEER when SEER is not available RoomAirCond: Roam air conditioner. Minimum SEER varies' LgPkgAirCond: Large packaged air conditioner(a 65,000 Btu/hr output). Substitute EER for SEER when SEER is not available EvapDirect: Direct evaporative cooling system. For compliance calculation purposes, fixed values: SEER=11.0;duct location-attic;duct insulation R-value= 4.2 Evapindirect: Indirect evaporative cooling system. For compliance calculation purposes, fixed values: SEER—13.0;duct location-attic;duct insulation R-value= 4.2 _ •Refer to Commission publication Appliance Efficiency Regulations,P400-92-029 l Revised March 1,1996 a e INSTALLATION CERTIFICATE (p 4 of )• CF-6R The following an explanation of many of the input values required on this form: i WATER HEATING SYSTEMS Distribution Systems Refer to Residential Manual for more details: Standard: Standard Pipe Insulation: Pipe Insulation on all 3/4-inch pipes POU/HWR: Point of Us.-/Hot Water Recovery System Recire/NOControl: Recirculation loop with no controls Recirc/fimen Recirculation loop with a timer Recirc/Temp: Recirculation loop with temperature control Recirc(rime+Temp: Recirculation loop with a timer and temperature control Recirc/Demand: Recirculation loop with demand control �yter Heuer Tvoe Information Needed Fneryv Factor Recove t Efficiency Standby Loss Rated llipw Storage Gas,Oil or Electric Yes No No No Heat Pump Yes No No No Instantaneous Gas No Yes No No Instantaneous Electric Yes No No No Large Storage Gas No Yes Yes Yes Indirect Gas(Boiler) No Yes(AFUE) No Yes ^NF STRATION/CLAZING Fenestration: Windows,sliding glass doors,french doors,skylights,garden windows,and any door with more than one square foot of glass Operator Type: Slider,hinged,fixed U-Value: Installed U-value must be less than or equal to value from CF-I R OR Installed weighted average U-value for the total fenestration area is less than or equal to value from CF-1R Revised March 1,1996 INSULATION CERTIFICATE IC-1 Number and Street ty County Subdivision Lot Number Description of Installation 1. ROOF Material Brand Name Thickness(inches) Thermal Resistance(R-Value) 2. CEILING Batt or Blanket Type Brand Name Thickness(inches) Thermal Resistance(R-Value) Loose Fill Type Brand Contractor's min installed weight/R' Ib Minimum thickness inches Manufacturer's installed weight per square foot to achieve Thermal Resistance(R-Value) 3. EXTERIOR WALL Frame Type A. Cavity Insulation Brand Na Material me Thickness(inches) Thermal Resistance(R-Value) B. Exterior Foam Sheathing Material Brand Name Thickness(inches) Thermal Resistance(R-Value) 4. RAISED FLOOR Material Brand Name Thickness(inches) Thermal Resistance(R-Value) 5. SLAB FLOOR/PERIMETER Brand Name Material Thickness(inches) Thermal Resistance(R-Value) Perimeter Insulation Depth(inches) 6. FOUNDATION WALL Material Brand Name Thickness(inches) Thermal Resistance(R-Value) Declaration I hereby certify that the above insulation was installed in the building at the above location in conformance with the current Energy Eficiency Standards for residential buildings(Title 24,Part 6,California Code or Regulations)as indicated on the Certificate of Compliance,where applicable. Item#s Signature,Date Installing Subcontractor(Co.Name)OR General Contractor(Co.Name)OR Owner Item#s Signature,Date Installing Subcontractor(Co.Name)OR General Contractor(Co.Name)OR Owner Item#s Signature,Date Installing Subcontractor(Co.Name)OR General Contractor(Co.Name)OR Owner Revised March 1,1996 FALL STRUCTURRL SULLIVANB ` 8/2 SULCONSTRUCTION RESANI RESIDENCE REMODEL G.. BI2 D. 81200 Consulting Engineers Inc. 20687 CRAIG CT. .- Page Phone:(408)559-0340 1317 BEAM: R1 Span = 16.00' Left Cantilever=0.00' Right Cantilever=0.00' LOADS: Type Name X(') Load(psf) TW1(') TL(') TW2(') Red P ROOF 7.50 23.00 8.00 12.00 8.00 1.00 REACTIONS: @X=0.00' R=-1173.00# @X=16.00' R=-1035.00# STATIC VALUES AND DEFLECTIONS: X(') UL(#) OR(#) M('#) Y(") 0.00 0.00 1173.00 000 0.00 7.50 1173.00 -1035.00 8797.50 201.89 7.84 -1035.00 -1035.00 844546 202.42 1600 -1035.00 0.00 000 0.00 Q max=1173.00# M max=8797.50'# Y max=202.42",for E=1.6E6,1= 1 PROPOSED SECTIONS L.D.F.= 1.25 Allow. Defl=Span/240.00 for DL+ LL Mat+E A(In^2) S(In^3) 1(in^4) Fv/fv(PSI) CfCvFb/fb(PSI) Defl(In) OF#1 Lumber (E=1700000) Read: 14.82 84.46 238.16 118.75 1250.00 0.80 Eff:3.5 x 13 25 46.38 102.41 678.48 37.94 1030.84 0.28 Multiole OF#1 (E=1700000) Read: 14.82 73.44 238.16 118.75 1437.50 0.80 Eff:4.5 x 11.25 50.63 94.92 533.94 34.76 1112.18 0.36 Read. 14.82 66.76 238.16 118.75 1581.25 0.80 Eff 6 x 9.25 55.50 85.56 395.73 31.70 1233.83 0.48 OF#1 Timber (E=1600000) Read: 16.56 64.97 253.05 106.25 1625.00 0.80 Eff:5.5 x 9.5 52.25 82.73 392.96 33.67 1276.09 0.52 Read: 16.56 64.97 253.05 106.25 1625.00. 0.80 Eff:7.5 x 7.5 56.25 70.31 263.67 31.28 1501.44 0.77 Glulam 24F (E=1800000) Reqd: 8.53 35.19 224.93 206.25 3000.00 0.80 Eff:3.125 x 10.5 32.81 57.42 301.46 53.62 1838.50 0.60 Read. 8.53 35.19 224.93 206.25 3000.00 0.80 Eff:5.125 x 9 46.13 69.19 311.34 38.15 1525.85 0.58 Read: 8.53 35.19 224.93 206.25 3000.00 0.80 Eff.6.75 x 7.5 50.63 63.28 237.30 34.76 1668.27 0.76 Microlam (E=1900000) Read: 4.94 32.48 213.09 356.25 3250.00 0.80 Eff:1.75 x 11.875 20.78 41.13 244.21 84.67 2566.77 0.70 Read: 4.94 32.48 213.09 356.25 3250.00 0.80 Eff:3.5 x 9.5 33.25 52.65 250.07 52.92 2005.29 0.68 Read 4.65 29.12 213.09 362.50 3625.00 0.80 Eff.7 x 7.25 50.75 61.32 222.30 34.67 1721.54 0.77 Paralam (E=2000000) Read. 4.85 29.12 202.44 362.50 3625.00 0:80 Eff:2.6875 x 11.875 31.91 63.16 375.03 55.13 1671.38 0 43 Read: 4.85 29.12 202.44 362.50 3625.00 0.80 Eff.3 5 x 9 5 33.25 52.65 250.07 52.92 2005.29 0.65 USE: SIZE: 4X14 MATERIAL: DF#1 CONNECTIOVS: DET. B5 QPpFE p SUPPORT: 4X4 POSTS of C' REMARKS: FLUSH WITH CEILING,TRIM TO MATCH SLOPE 0 3008 .331/05 ILL STRUCTURRL ""'' SULLIVAN CONSTRUCTION BRESANI RESIDENCE REMODEL G.D. 8128/200 Consulting Engineers Inc. 20687 CRAIG CT. I.- Pauc Phone:(408)559-0340 1317 BEAM: R2 Span = 12.80' Left Cantilever=0.00' Right Cantilever=0.00' LOADS: Type Name X(') Load(psf) TW1(') TL(') TW2(') Red W ROOF 0.00 28.00 7.50 12.80 7.50 1.00 REACTIONS: @X=0.00' R=-1344.00# @X=12.80' R=-1344.00# STATIC VALUES AND DEFLECTIONS: X(') GL(#) OR(#) M(-#) Y(") 000 000 1344.00 000 0.00 6 40 000 000 4300.80 79.27 12.80 •1344 00 0.00 000 0.00 Q max=1344.00# M max=4300.80'# Y max=79.27",for E=1.6E6, I=1 PROPOSED SECTIONS L.D.F.= 1.25 Allow. Defl=Span/240.00 for DL+LL Mat+E A(in"2) S(in A 3) 1(in-4) Fvlfv(PSI) CfCvFb/fb(PSI) Defl(in) DF#1 Lumber (E=1700000) Read: 14.93 37.53 116.58 118.75 1375.00 0.64 Eff:3 x 9.25 27.75 42.78 197.86 63.90 1206.36 0.38 Multiple OF#1 (E=1700000) Read: 14.05 39.89 116.58 118.75 1293.75 0.64 Eff:1.5 x 13.25 1988. 43.89 290.78 83.93 1175.87 0.26 Read. 15.37 31.76 116.58 118.75 1625.00 0.64 Eff:4.5 x 7.25 32.63 39.42 142.90 55.96 1309.16 0.52 DF#1 Timber (E=1600000) Read: 17.12 31.76 123.86 106.25 1625.00 0.64 Eff:5.5 x 7.5 41.25 51.56 193.36 44.10 1000.91 0.41 Glulam 24F (E=1800000) Read: 8.82 17.20 110.10 206.25 3000.00 0.64 Eff:3.125 x 7.5 23.44 29.30 109.66 77.62 1761.61 0.64 Read: 9.01 17.20 110.10 206.25 3000.00 0.64 Eff:6.75 x 6 40.50 40.50 121.50 45.89 1274,31 0.58 Microlam (E=1900000) Read: 4.96 15.88 104.31 356.25 3250.00 0.64 Eff:1.75 x 9.5 16.63 26.32 125.03 106.26 1960.63 0.53 Read: 5.12 15.88 104.31 356.25 3250.00 0.64 Eff:3.5 x 7.25 25.38 30.66 111.15 71.95 1683.21 0.60 Paralam (E=2000000) Read: 4.87 14.24 99.09 362.50 3625.00 0.64 Eff:2.6875 x 9.5 25.53 40.42 192.02 69.19 1276.69 0.33 Read: 5.04 14.24 99.09 362.50 3625.00 0.64 Eff:3.5 x 7.25 25.38 30.66 111.15 71.95 1683.21 0.57 USE: SIZE: 4X12 MATERIAL: DF#2 CONNECTIONS: EPC44 SUPPORT: 4X4 POSTS REMARKS: BELOV'l JOISTS 1,34 = 21� 1 K L nLL STRUCTURAL SULLIVAN CONSTRUCTION BRESANI RES;DENCE REMODEL G.D. 8/28/200 Consulting Engineers Inc. 20687 CRAIG CT. Paye Phone(408)559-0340 1317 BEAM: R1 Span= 16.00' Left Cantilever=0.00' Right Cantilever=0.00' LOADS: Type Name X(') Load(psf) TW1(') TL(') TW2(') Red P ROOF 7.50 23.00 8.00 12.00 8.00 1.00 REACTIONS: @X=0.00' R=-1173.00# @X=16.00' R=-1035.00# STATIC VALUES AND DEFLECTIONS: X(') OL(#) OR(#) M('#) Y(") 000 OCC) 1173.00 000 000 750 117300 -103500 8797 50 201.89 784 .103500 -1035.00 844546 20242 1600 •1035.00 000 000 0.00 Q max=1173.00# M max=8797.50'# Y max=202.42",for E=1.6E6, 1=1 i PROPOSED SECTIONS L.D.F. = 1.25 Allow. Defl=Span/240.00 for DL+LL Mat+E Alin^2) S(in A 3) 1(in A 4) Fv/tv(PSI) C1CvFb/fb(PSI) Defi(in) OF#1 Lumber (E=1700000) Read: 1402 84.46 238.16 118.75 1250.00 0.80 Eff:3.5 x 13.25 46.38 102.41 678.48 37.94 1030.84 0.28 Multiple OF#1 (E=1700000) Read: 14.82 73.44 238.16 118.75 1437.50 0.80 Eff:4.5 x 11.25 50.63 94.92 533.94 34.76 1112.18 0.36 Read. 14 82 66.76 238.16 118.75 1581.25 0.80 Eff:6 x 9.25 55.50 85.56 395.73 31.70 1233.83 0.48 OF#1 Timber (E=1600000) Read. 16.56 64.97 253.05 106.25 1625.00 0.80 Eff:5.5 x 9.5 52.25 82.73 392.96 33.67 1276.09 0.52 Read: 16.56 64.97 253.05 106.25 1625.00 0.80 Eff:7.5 x 7.5 56.25 70.31 263.67 31.28 1501.44 0.77 Glulam 24F (E=1800000) Read 8.53 35.19 224.93 206.25 3000.00 0.80 Eff:3 125 x 10.5 32.81 57.42 301.46 53.62 1838.50 0.60 Read. 8.53 35.19 224.93 206.25 3000.00 0.80 Eff:5.125 x 9 46.13 69.19 311.34 38.15 1525.85 0.58 Read: 4.53 35.19 224.93 206.25 3000.00 0.80 Eff 6 75 x 7.5 5P.63 63.28 237.30 34.76 1668.27 0.76 Microlam (E=1900000) Read: 4.94 32.48 213.09 356.25 3250.00 0,80 Eff.1 75 x 11 875 2078 41.13 244.21 84.67 2566.77 0.70 Read. 4.94. 32.48 213.09 356.25 3250.00 0.80 Eff.3.5x95 33.25 52.65 250.07 52.92 2005.29 0.68 Read: 4.85 29.12 213.09 362.50 3625.00 0.80 Eft 7 x 7.25 5075 61.32 222.30 34.67 1721.54 0.77 Paralam (E=2000000) Read: 4.85 29.12 202.44 362.50 3625.00 0.80 Eff:2.6875 x 11.875 31.91 63.16 375.03 55.13 1671.38 0.43 Read: 4.85 29.12 202.44 362.50 3625.00 0.80 Eff:3.5 x 9.5 33.25 52.65 250.07 52.92 2005.29 0.65 USE: SIZE: 4X14 Q FE MATERIAL: DF#1 CONNECTIONS: DET.B5 SUPPORT: 4X4 POSTS No. REMARKS: FLUSH WITH CEILING,TRIM TO MATCH SLOPE ('� a RLL STRUCTURRL C1fi. '°a SULLIVAN CONSTRUCTION BRESANI RESIDENCE REMODEL G.D. 8/28/200 Consulting Engineers Inc. 20687 CRAIG CT. Page Phone:(408)559-03•.0 1317 BEAM: R2 Span= 12.80' Left Cantilever=0.00' Right Cantilever=0.00' LOADS: Type Name X(') Load(psf) TW1(') TL(') TW2(') Red W ROOF 0.00 28.00 7.50 12.80 7.50 1.00 REACTIONS: @X=0.00' R=-1344.00# @X=12.80' R=-1344.00# STATIC VALUES AND DEFLECTIONS: x0 OL(#) OR(#) MI'#) Y(11 0.00 000 1344.00 000 000 640 000 000 4300.80 79.27 1280 -1344 00 0.00 0.00 0.00 Q max=1344.00# M max =4300.80'# Y max=79.27",for E=1.6E6, 1=1 PROPOSED SECTIONS L.D.F.= 1.25 Allow.Defl=Span/240.00 for DL+LL Mat+E A(in^2) S(in"3) 1(in"4) Fv/fv(PSI) CfCvFblfb(PSI) Defl(In) DF#1 Lumber (E=1700000) Read: 14.93 37.53 116.58 118.75 1375.00 0.64 Eff:3 x 9.25 27.75 42.78 197.86 63.90 1206.36 0.38 Multiole DF#1 (E=1700000) Read: 14.05 39.89 116.58 118.75 1293.75 0.64 Eff:1.5 x 13.25 19.88 43.89 290.78 83.93 1175.87 0.26 Read: 15.37 31.76 116.58 118.75 1625.00 0.64 Eff.4.5 x 7.25 32.63 39.42 142.90 55.96 1309.16 0.52 OF#1 Timber (E=1600000) Read: 17.12 31.76 123.86 106.25 1625.00 0.64 Eff:5.5 x 7.5 41.25 51.56 193.36 44.10 1000.91 0.41 Glulam 24F (E=1800000) Read: 8.82 17.20 110.10 206.25 3000.00 0.64 Eff:3.125 x 7.5 23.44 29.30 109.86 77.62 1761.61 0.64 Read. 9.01 17.20 110.10 206.25 3000.00 0.64 Eff:6.75 x 6 40.50 40.50 121.50 45.89 1274.31 0.58 Miuolam (E=1900000) Read: 4.96 15.88 104.31 356.25 3250.00 0.64 Eff:1.75 x 9.5 16.63 26.32 125.03 106.26 1960.63 0.53 Read: 5.12 15.88 104.31 356.25 3250.00 0.64 Eff:3.5 x 7.25 25.38 30.66 111.15 71.95 1683.21 0.60 Paralam (E=2000000) Read: 4.87 14.24 99.09 362.50 3625.00 0.64 Eff:2.6875 x 9.5 25.53 40.42 192.02 69.19 1276.69 0.33 Read: 5.04 14,24 99.09 362.50 3625.00 0.64 Eff:3.5 x 7.25 25.38 30.66 111.15 71.95 1683.21 0.57 USE: SIZE: 4X12 MATERIAL: DF#2 CONNECTIONS: EPC44 SUPPORT: 4X4 POSTS REMARKS: BELOW JOISTS . � L