Loading...
09080141I CITY OF CUPERTINO BUILDING PERMIT I I BUILDING ADDRESS: 10210 STERN AVE I CONTRACTOR: SOLARCITY I PERMIT NO: 09080141 I OV ER'S NAME: RALPH BRUNNER G R'S PHONE: 4089967066 ❑ LICENSED CONTRACTOR'S DECLARATION License Class CAO C4-0 t) Lic. # S g�( 0�1 Contractor rCk Date I hereby affirm that I am licensed under the provisions of Chapter'9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature lit ► t-1 �/ Date ❑ OWNER -BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business & Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: 1 have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter ups- the above mentioned property for inspection purposes. (We) agree to save ii ify and keep harmless the City of Cupertino against liabilities, judgments, cow., and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature Date. 393 VINTAGE PARK DR STE 140 I DATE ISSUED: 08/26/2009 FOSTER CITY, CA 94404 PHONE NO: (650) 638-1028 BUILDING PERMIT INFO: BLDG ELECT PLUMB MECH RESIDENTIAL -I_-_MMERCIAL JOB DESCRIPTION: 2.25 KW ROOF FLUSH MOUNT PHOTOVOLTAIC SYSTEM Sq. Ft Floor Area: I Valuation: $18000 APN Number: 37512001.00 1 Occupancy Type: PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Issue Date Z 6c-te RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. 1 will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Sections 25505, 25533, and 25534. Ow 1 r or author' ed agent: /� p j m Date: d D oZ CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed Professional I CITY OF CUPERTINO BUILDING PERMIT I I BUILDING ADDRESS: 10210 STERN AVE I CONTRACTOR: SOLARCrrY I PERMIT NO: 09080141 1 OWNER'S NAME: RALPH BRUNNER 393 VINTAGE PARK DR STE 140 1 DATE ISSUED: 08262009 OWNER'S PHONE: 4089967066 FOSTER CITY, CA 94404 1 PHONE NO: (650) 639-1028 1 ❑ LICENSED CONTRACTOR'S DECLARATION License Class C10 C" t>Lic.9 g$91 171 a r LL 1 N Date Contractor J 1 hereby affirm that 1 am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations 1 have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. 1 have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that 1 have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify, and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18, ❑ OWNER -BUILDER DECLARATION 1 hereby affirm that 1 am exempt from the Contractor's License Low for one of the following two reasons: I, as owner of the property, or my employees with wages as thew sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). 1 hereby affirm under penalty of perjury one of the following three declarations: I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the labor Code; for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. I certify that in the performance of the work for which this permit is issued,) shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, become subject to the Worker's Compensation provisions of the labor Code, I must forthwith comply with such previsions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and stale that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep ham less the City of Cupertino against kabilitim,judgrnmts, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Date r�-� r-- F�-- BUILDING PERMIT INFO: BLDG ELECT PLUMB MECH r RESIDENTIAL r COMMERCIAL r JOB DESCRIPTION:2.25 KW ROOF FLUSH MOUNT PHOTOVOLTAIC SYSTEM Sq. Ft Floor Area: I Valuation: $18000 APN Number: 37512001.00 1 Occupancy Type: PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Issue Date 2 47 t RE -ROOFS: All mots shall be inspected prior to any roofing material being installed. If a mof is installed without first obtaining an inspection, 1 agree to remove all new materials for inspection. Signature of Applicant: Date: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE 1 have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. 1 will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emir hazardous air contaminants as defined by the Bay Area Air Quality Management District 1 will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Sections 25505, 25533, and 25534. Ow r or,,eut�h�o�' ed agent: p (A1Q,f (il9U1f.()() YM Date: I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's Address 1 understand my plans shall be used as public records. Licensed ITEM 1 OF 1 CITY OF CUPERTINO PERMIT RECEIPT Sec: Twp: Rng: Sub: Blk: Lot: APN ........: 37512001.00 DATE ISSUED.......: 08/17/2009 RECEIPT #.........: BS000008451 REFERENCE ID # ...: 09080141 SITE ADDRESS .....: 10210 STERN AVE SUBDIVISION ....... CITY .............: CUPERTINO IMPACT AREA ....... OWNER ............: RALPH BRUNNER ADDRESS ..........: 10210 STERN AVE CITY/STATE/ZIP ...: CUPERTINO, CA 95014 OPERATOR: SylviaM COPY # : 1 RECEIVED FROM .....: SOLARCITY CONTRACTOR .......: LYNDON RIVE LIC # 28844 COMPANY ........-..: SOLARCITY ADDRESS...........: 393 VINTAGE PARK DR STE 140 CITY/STATE/ZIP ...: FOSTER CITY, CA 94404 TELEPHONE ........: (650) 638-1028 FEE ID UNIT QUANTITY' AMOUNT PD -TO -DT THIS REC NEW SAL ---------- --------------------------------- ---------- ---------- ---------- 1PHOTOVRES EACH 1.00 207.00 0.00 207.00 0.00 ---------- ---------- ---------- ---------- TOTAL PERMIT 207.00 0.00 207.00 0.00 METHOD OF PAYMENT ----------------- CHECK TOTAL RECEIPT : AMOUNT --------------- 207.00 ---------207.00 VOICE ID DESCRIPTION -- ------------------- 301 ROUGH PLUMBING 304 ROUGH ELECTRICAL 505 FINAL ELECTRICAL 508 FINAL MECHANICAL REFERENCE NUMBER -------------------- 110551 VOICE ID DESCRIPTION ----- ------------------ 303 ROUGH MECHANICAL 313 ROOF NAIL 507 FINAL PLUMBING E�' CITY OF CUPEI,TINO Community Development 10300 Torre Avenue Cupertino CA 95014 Telephone (408) 777-3228 Fax (408) 777-3333 Building Department JOB ADDRESS: \ 0M Y PERMIT # OWNER'S NAME: PHONE # q (p--70 GENERAL CONTRACTOR `A FAX # -Z 2— 102 8 I am not using any subcontractors: Cat I -i 109 Signature Da?e Please check applicable subcontractors and complete the following information: Owner/ Contractor Signature Date SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring: Carpeting Linoleum / Wood Glass / Glazing Heating Insulation Landscaping Lathing Masonry Ornamental Sheet Metal Painting / Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile Owner/ Contractor Signature Date 7CITY. OF CUPERTINO SOLAR PANEL CUPEkTiNO PERMIT'APPLICATION FORM n g6g-d / Y / APN # - S' :1Z oof:ba Fee ID - - ,: Date: 19 ca Building Address: JT -. Permit Type Owner's Nam CommercW,Solar Panel E Phone #: I PHOTOVCOM " Photovoltaic System Commercial 4�c&- C�tractor: Phone #: I BSEISMICO' Contractor License #: E Fax #: I ELCPLNCK Contact: oe P09&-4,33 a� Cupertino Business License #: c-)40 yT Ss+' 1 T� i "acU'Wni 1 �s� CITY OF CUPEkTINO Community Development 10300 Torre Avenue Cupertino CA 95014 Telephone (408) 777-3228 Fax (408) 777-3333 Building Department All Cupertino building permits must meet certain conditions related to maintaining environmental quality and public peace and safety. The two most common conditions are described below. STORMWATER POLLUTION CONTROL State law requires that Cupertino, 12 other Silicon Valley cities, Santa Clara County and the Santa Clara Valley Water District control stormwater pollution. Educating local residents and businesses and enforcing stormwater pollution control laws are key parts of the City's compliance efforts. Stormwater pollution prevention: It's up to us In northern Santa Clara Valley, storm drains flow directly to local creeks and San Francisco Bay, with no treatment. Stormwater pollution is a serious problem for wildlife dependent on ourwaterways, for people living near streams and baylands, and for the local water supply. Common sources of stormwater pollution include: • Dripped oil, fuel, and antifreeze from vehicles and heavy equipment; • Construction debris, including dirt, concrete and paint; • Landscaping runoff containing pesticides or weed killers; and Any material dumped or spilled into streets or storm drains The property owner and the contractor share ultimate responsibility for activities occurring at a construction site and will be held responsible for any environmental damage caused by subcontractors or employees. For more information on construction -related stormwater requirements, see the Stormwater Quality Regulations section of the City of Cupertino web site at: httii://www.cui)ertino.orci/city government/departments and offices/ environmental services COMMUNITY NOISE CONTROL 001ERCE COPY The basic noise control requirements for construction sites are a. • Typical construction work hours are: - Weekdays - 7 a.m. to 8 p.m. - Weekends - 9 a.m. to 6 p.m. • Construction other than street construction is prohibited on, holidays. • Residential daytime noise levels from complaint site - 60 dBA • Nonresidential daytime noise levels from complaint site - 65 dBA For more information on noise control, please see Chapter 10.48 of the Cupertino I Municipal Code, which can be accessed at http•//www.amlegal.com/cuoertino ca/ Greg Casteel Building Official RECEIVED AUG 17 2009 BY: - LABELS ELECTRICAL NOTES GENERAL NOTES LEGEND ABBREVIATIONS PHO10104341C MINT OF iNTERMIDECTION WARNING! ELECTRIC SHOCK RAWO! 1. WHERE ALL TERMINALS OF THE 1. THIS SYSTEM IS GRID-INTERTIED VIA A UL -LISTED O (E) UTILITY METER A AMPERE ' DISCONNECTING MEANS MAY BE ENERGIZED POWER -CONDITIONING INVERTER. AC ALTERNATING CURRENT �Y IN THE OPEN POSITION, A SIGN WILL BE 2. ALL INVERTERS AND ARRAYS ARE NEGATIVELY GROUNDED. mGRID-TIED INVERTER BLDG BUILDING mor PROVIDED WARNING OF THE HAZARDS PER 3. THIS SYSTEM HAS NO BATTERIES, NO UPS. ,r• ART. 690.17. 4. SOLAR MOUNTING FRAMING ARE TO BE GROUNDED. DG DC DISCONNECT DONC IN ECCDI I jEDVEDTHE CITY OFS '"' SOlarci .� 2. EACH UNGROUNDED CONDUCTOR OF THE 5. ALL WORK TO BE DONE TO 2007 CALIFORNIA BUILDING CODE. C MULTIWIRE BRANCH CIRCUIT WILL BE 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2005DC DAOIRECL WARN1Nta ELECTIUC SN06N HA7AROt IDENTIFIED BY PHASE AND SYSTEM PER NATIONAL ELECTRIC CODE AS AMENDED BY THE 2007 ® AC DISCONNECT OPERATING VOLTAGE ART. 210.5. CALIFORNIA ELECTRIC CODE. EGC PM s G�R!tr�q�IRNG�tCONDUCTOR v O td1!t1Flllndllut4iryG 3. ANATIONALLY-RECOGNIZED TESTING COMBINER BOX �a NAziN OPERATING GALVuete'Mku 10WA64lfl1ZL"Banges or alterations CURRENT " EMT De LABORATORY SHALL UST ALL EQUIPMENT DISTRIBUTION PANEL a!same ' t IN COMPLIANCE WITH ART. 110.3. . GEC DiNsCBE L"ff89®EtObNDUCTOR C: 4. CIRCUITS OVER 250V TO GROUND SHALL INDEX " SUiarCit . Win, GND The stamp• ,,mp,�!� ac so�lgC�u�ations COMPLY WITH ART. 250.97, 250.92(6) PHOTOVOLTAIC MODULE HOG SHALL NH �eQ16169®pi�an PHOTOVOLTAIC uc DISCONNECT 5. DC CONDUCTORS EITHER DO NOT ENTER PVl COVER SHEET IC SHOCK HAMI BUILDING OR ARE RUN IN METALLIC I @8RRMraion ofanyprovisions WARKM ELECTRIC PV2 SITE PLAN • (E) VENT PIPE Imp �'19R�9Vf'A•T4NIGXaP0WER v: v PV3 STRUCTURAL VIEWS RACEWAYS OR ENCLOSURES TO THE FIRST INVS INVERTERS n,m III ACCESSIBLE DC DISCONNECTING MEANS PV4 UPLIFT CALCULATIONS (E) SKYLIGHT Isc SHORT CIRCUIT CURRENT PER � ART. 690.31(E). PV5 SINGLE UNE n KVA KILOVOLT AMPERE 6. ALL WIRES SHALL BE PROVIDED WITH PV6 ELECTRICAL CALCULATIONS (E) CHIMNEY KW KILOWATT -' SOIarClty STRAIN RELIEF AT ALL ENTRY INTO BOXES PV7 CUTSHEETS LBW LOAD BEARING WALL AS REQUIRED BY UL LISTING. PV8 CUTSHEETS MIN MINIMUM 7. MODULE FRAMES SHALL BE GROUNDED AT PV9 CUTSHEETS • r THE UL-USTED LOCATION PROVIDED BY LICENSE NEC NAi1WONAL ELECTRIC CODE THE MANUFACTURER USING UL LISTED NIC NOT IN CONTRACT GROUNDING HARDWARE. NTS NOT TO SCALEjJ d% 8. ALL EXPOSED METAL PARTS (MODULE CA k 888104 c • OC ON CENTER • • I FRAMES, RAIL, BOXES, ETC.) SHALL BE C-46, C-10 P PANEL BOARD' GROUNDED USING UL LISTED LAY -IN LUGS VICINITY MAP PL PROPERTY LINES USTED FOR THE PURPOSE. POSTS SHALL PV PHOTOVOLTAIC BE MADE ELECTRICALLY CONTINUOUS WITH acall PVC POLYVINYL CHLORIDE ATTACHED RAIL. g AF:ttAve o S SUBPANEL E E 9. MODULE FRAMES, RAIL, AND POSTS SHALL lenrry • 6 x ;Strand Park st Ava. SCH SCHEDULE BE BONDED WITH EQUIPMENT GROUNDa SS STAINLESS STEEL CONDUCTORS AND GROUNDED AT THE z t3J'•1 ���JJJsom iDw Ave SSD SEE STRUCTURAL DRAWINGS r . MAIN ELECTRIC PANEL. f ma1looPk"V_q � u7 Ga m < 10. IF THE EXISTING AC GROUNDING ^ h,: �I ,STC STANDARD TESTING CONDITIONS C�� ELECTRODE IS A COPPER ROD, THE DC • ra %BantteltAve: SWH SOLAR WATER HEATER GEC SHALL BE EITHER #8 THWN-2 RUNICAL C Y////�\��' 'IIS $ 0 , UNLESS OTHERWISE NOTED INSIDE CONDUIT BONDED AT BOTH ENDS, L� n V /VOLT, OR �j6 BARE COPPER RUN ALONG 1 m- Vm VOLTAGE ATfM X: POWER3 BUILDING AS LONG AS IT IS NOT SUBJECT SCeverlsCreekBN(1 StevereCreekt3hrd P I�., COPVoc VOLTAGE'AT OREN CIRCUIT TO PHYSICAL HARM PER ART. - n C W WATT �� r u� 250.166(B)&(C), 250.64(B)&(E). IF THEI T J r 3R NEMA 3R, RAINTIGHT EXISTING AC GROUNDING ELECTRODE ISA o - CONCRETE -ENCASED ELECTRODE, THE DC I °i Calvert d a REV BY DATE COMMENTS GEC SHALL BE A #6 THWN-2 .< D .'. ,r1eY O u LareoAve 6�1i F'w_ REV • r • , 250.166(D). THE GEC SHALL BE < a >♦ R CONTINUOUS AS DESCRIBED IN ART.�� a Ca H r I orae Ati o Lane Aved e A n �Y • 250.64(C). E _ �. I .l 'R y Ct l 6 Ja PRaCT MANAGER: P CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT RESI BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC. NOR DESIGN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS ORSIDE IT THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE DATE CASH SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT. WITHOUT T 'dr. i (30) FIRSTSOLAR # FS -275 SOLARCITY CANOPY -T 8" POST & RAIL FRONIUS # IG 2000 al. PV > R ! m s BRUNNER, RALPH BRUNNER RESIDENCE CLI51MU ADDRESS. 2.25 kW ROOF MOUNT PV SYSTEM 10210 STERN AVE JOB NUMBER CUPERTINO, CA 95014 (240) 408-996-7066 JB -950131 00 REV: _ larCi Faster City, CA 9Ga00 T:(650) 638-10281 F:(650)638-1029 (888) -SOL -CM (7652,$89I 1 www.Solarcit SITE PLAN Scale: 3/32" = V N W E S �n�r�rs��eer; vur a�rmxz's. u:n�r miiens.�i SHEET NOTES 1. INVERTER, DC DISCONNECT, & WARNING LABEL (2), IN GARAGE. 2. UNUSED. 3. AC DISCONNECT & WARNING LABELS (2), (4), (6) IN GARAGE. 4. UTILITY METER, DISTRIBUTION PANEL & WARNING LABELS (1), (2), (4), (6). 5. DC DISCONNECT & WARNING LABELS (3), (5) IN GARAGE. 6. DC COMBINER BOX & WARNING LABELS (7), (9). 7. UNUSED. 8. UNUSED. 9. UNUSED. 10. CONDUIT ROUTED ON ROOF. 11. CONDUIT ROUTED ON WALL. 12. REFER TO PV1 FOR WARNING LABELS 13. FLASHINGS WILL BE PAINTED TO MATCH ROOF COLOR. 20' TO R FRONT OF HOUSE MP2 ROOF MOUNT PITCH: 18 ARRAY PITCH: 18 AZIMUTH: 270 ARRAY AZIMUTH: 270 MATERIAL: Concrete — Spanish STORY: 2 RAFTERS SIZE: 2x10 SPACING: 24" O.C. SUPPORT: 202 HIPS MAX. SPAN: 7'-8" NOTES WEST FACING MOUNTING PLANES 9VT MANAGER: CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT Y1AN - RESI BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC. NOR (30) FIRSTSOLAR # FS -275 ESIGN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDESOLARCITY CANOPY -T 8" POST& RAIL 1T THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE ATE CASH SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT 6/13/2009 THE WRITTEN PERMISSION OF SOLARCITY INC. (1) FRONIus tt to 2000 8' TO R PTV ��! id 000111DI: ON: BRUNNER, RALPH BRUNNER RESIDENCE 2 Solalci — WPM mom 2.25 kW ROOF MOUNT PV SYSTEM 10210 STERN AVE JOB NUMIRR CUPERTINO, CA 95014 393 Vintage Faste Park DriCA 9,404 140 (za) JB -950131 00 63&1 any, CA 94404 REV: 7:16501838-10281 F:(650)636-1029 406-996-7066 — 30' / TO R MP3 ROOF MOUNT PITCH: 18 1 ARRAY PITCH: 18 AZIMUTH: 90 ARRAY AZIMUTH: 271 MATERIAL: Concrete — Spanish B STORY: 2 PV3 MP AS TYp.) o RAFTERS MP 17 SIZE: 2x10 SPACING: 24" O.C. ®MP #9 SUPPORT: 2x12 HIPS G V MAX. SPAN: 11'-2" A MP 1 PV3 NOTES A2 M y5 EAST FACING MOUNTING (TYP) OMP 0 P PLANC 46 MP ;p4 MP g3 MP1 ROOF MOUNT PITCH: 18 ARRAY PITCH: 18 AZIMUTH: 180 ARRAY AZIMUTH: 180 10 MATERIAL: Concrete — Spanish STORY: 2 AC :_; r RAFTERS r--- ( Inv , h SIZE: 2x10 I ----- SPACING: 24" O.C. SUPPORT: 2x12 HIPS O 1 5 MAX. SPAN: 11'-6" 15 NOTES 4 TO _ SOUTH FACING MOUNTING offlUt-1 Copy PTV ��! id 000111DI: ON: BRUNNER, RALPH BRUNNER RESIDENCE 2 Solalci — WPM mom 2.25 kW ROOF MOUNT PV SYSTEM 10210 STERN AVE JOB NUMIRR CUPERTINO, CA 95014 393 Vintage Faste Park DriCA 9,404 140 (za) JB -950131 00 63&1 any, CA 94404 REV: 7:16501838-10281 F:(650)636-1029 406-996-7066 — -10 (E) LBW RAFTERS: 2x10 0 24" O.C. SUPPORT: LBW MAX SPAN: SIDE VIEW OF MOUNTING PLANE (TYP.) Scale: 1/4"=1'-0" SOLAR PANEL ATTACHED W TH SPACER, CLAMP & HI SOLARCITY SOLAR RAIL 8" POST GECKO BRACKET (E) SPANISH TILE (E) ROOF DECKING 5/16" DIA LAG BOLT (2-1/2" EMBED, MIN) (E) RAFTER �'/ "" ice^' ® 24" SPACING FRONT VIEW OF MOUNTING PLANE rr-� STANDOFF INSTALLATION ORDER LOCATE RAFTER, MARK RAFTER LOCATION, AND REMOVE TILE. LACE CANOPY—T BASE & DRILL PILOT HOLES AT THE RAFTER LOCATION. SEAL PILOT HOLES AND BOTTOM OF STANDOFF WITH POLYURETHANE SEALANT. LAG STANDOFF INTO RAFTER, INSERT & TIGHTEN POST W/ CHANNEL LOCKS INSTALL FLASHING AND MOLD TO TILE NOTCH TILE W/ TILE SAW AND INSTALL IN ORIGINAL LOCATION SEAL MOUTH OF FLASHING AND INSTALL PIPE COLLAR Scale: 1/2"=1'-0" v-PHCE G"OPY P V -'b"o 3 PRUCT MANAGER: c CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT (30) FIRSTSOLAR k FS -275 BRUNNER, RALPH BRUNNER RESIDENCESolaigi RESI BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC. NORN,wusysu: 2.25 kW ROOF MOUNT PV SYSTEM DESIGN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE SOLARCITY CANOPY -T 8" POST &RAIL 10210 STERN AVE JT THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION HATH THE 10210 STERN CA 95D14 393 Vintage Park Drive, Suite 140 CUPEDATE CASH Foster City, CA 9C<0< SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT T:(650)639-10281 F:(650)638-1029 8/13/2009 THE WRITTEN PERMISSION OF SOLARCITY INC. (1) FRONLUS a IG 2000 (240) 408-996-7066 JB- Jr 131 00 REV: — (888)-Sol-CIW(]65-2489)1 w sodarcity,con Input Variables T GRO.P. REST CASH Calculations and Values Required Variables BRUNNER, RALPH Design wind pressures based upon: Mean roof height: 25 ASCE 7-05 Chapter 6 Wind Loading Exposure category: C Basic wind speed (or city in the future): 90 Equation 6.5.13.3: Component and Cladding Elements Importance factor (1 for residential): 1 Wind pressure P = qh*Cn*G Roof shape: pitched 6.5.10: Velocity pressure Roof angle (degrees): •18 _ qh = 0.00256*Kz*Kzt*Kd*VA2*1 Roof zone: 3 Contiguous sq. feet of array: 8 . _ From Table 6-3: Least width of the building: 13 Kz = 0.94 Obstructed wind flow? TRUE From Figure 6-4: Kzt = 1.00 Local Topaarahphical Features From Table 6-4: (choose "standard "or rater to pictures right, and below) Kd = 0.85 Type of hill: none From figure 6-1: Hill height (h) (ft): V = 90 Slope of hill (degrees): From table 6-1: Horizontal distance from hilltop to house (x): I = 1 eight from bottom of hill to mean roof height (z): From Velocity Pressure Equation: ch = 16.57 Design Wind Pressures From Figure 6-19B P (Ibs per sq. ft.) = qh*Cn*G Cn (uplift) = -3.04 Pd (downforce pressure) = 14.08 Cn (down) = 1.00 Pu (uplift pressure) _ -02.81 From 6.5.8.1 G = 0.85 Max Tributaty Area Feet Inches Individual Rows in Portrait X (E -W distance between standoffs) = 4 0 First Solar FS Series 2 Y (N -S distance between standoffs) = 2 0 Amax (sq. ft.) = 0.5*L*X L (length of panel in ft. perpendicular to rail) 3.94 X= 4.00 Module Rail Max. Span / Cantilever (in) = 721/2 34 Y = 2.00 Max Uplift Force on a Singe Standoff L = N/A Pmax (lbs.) = Amax*Pu Amax = 7.88 F Pmaz = •337 Factor of safety = FI*D*NI/Pmaz 250 = FI (pullout capacity of lag (lbs/inch)) Dead Load Calculations 2.50 = D (minimum lag thread depth) DL (lbs/sq. ft.) = (Mm+Mh)/(L*W) 2 = NI (number of lags per standoff) L (length of First Solar FS Series 2 modules) 3.94 ti 3:71 = Factor of safety W (width of First Solar FS Series 2 modules) 1.97 Mm (weight of First Solar FS Series 2 modules) 26.50 Point Load Calculations Mh (weight of hardware per module) = 5.89 PL (lbs) = Amax*DL - PIL 33 . ;DL = 4.17. _ Version 5_2 VENT DETAIL MINIMUM VENT HEIGHT IS 6" ABOVE THE SURFACE OF THE ROOF PER UPC SECTION 906.1. UPC SECTION 311.5 STATES "NO FITTING, FIXTURE, AND PIPING CONNECTION, APPLIANCE, DEVICE, OR METHOD OF INSTALLATION THAT OBSTRUCTS OR RETARDS THE FLOW OF WATER, WASTES, SEWAGE, OR AIR IN THE DRAINAGE OR VENTING SYSTEMS, IN AN AMOUNT GREATER THAN THE NORMAL FRICTIONAL RESISTANCE TO FLOW, SHALL BE USED UNLESS IT IS INDICATED AS ACCEPTABLE IN THIS CODE OR IS APPROVED PER SECTION 301.1 OF THIS CODE." FROM THIS SECTION, IT IS CLEAR THAT MOUNTING SOLAR MODULES OVER A VENT IN A MANNER THAT WILL NOT HAVE A GREATER FRICTIONAL RESISTANCE TO AIR FLOW WOULD BE ACCEPTABLE. EQUATIONS: THE FRICTIONAL RESISTANCE TO FLOW IS DIRECTLY PROPORTIONAL TO THE AREA THAT THE AIR CAN FLOW THROUGH. IN THE VENT THAT IS THE AREA OF THE VENT PIPE. Avent = 7*R2 WHEN THE AIR EXITS THE VENT, THE AREA IT HAS TO FLOW THROUGH IS THE CIRCUMFERENCE OF THE VENT TIMES THE VERTICAL DISTANCE BETWEEN THE VENT AND THE MODULE ABOVE (IN THIS CASE, WE ARE LEAVING THE DIAMETER OF THE VENT BETWEEN THE TOP OF THE VENT AND THE BOTTOM OF THE PANEL). THIS METHODOLOGY ASSUMES THE WORST CASE SCENARIO OF MOUNTING THE MODULES HORIZONTALY OVER THE VENT. IN ACTUALITY, THE MODULES WIL BE TILED WHICH WILL OFFER MORE AREA FOR AIR TO FLOW THROUGH. Agap = C*CLEARANCE Agap = 2*7r*R*D Agap = 4*TT*R2 4*iT*R2 > iT*R2 FROM THE EQUATIONS ABOVE, IT IS EVIDENT THAT MOUNTING THE MODULES IN THIS MANNER ALLOWS 4 TIMES THE AMOUNT OF AIR FLOW ABOVE THE VENT THAN IN THE VENT ITSELF. SOLAR MODULE ATTACHED TO ROOF BY STANDOFFS SIZED TO CREATE APPROPRIATE CLEARNCE DETERMINED BELOW SURFACE DIAM. CLEARANCE VENT HEIGHT NON -HEAT PRODt1CINC PLUMBING VENT PIPE 0 VENT HEIGHT WILL BE A MINIMUM OF 6 INCHES ABOVE THE ROOF, OR THE MINIMUM VALUE ALLOWED BY LOCAL BUILDING CODE. (LA CODE) • MINIMUM CLEARANCE BETWEEN THE TOP OF THE VENT AND THE BOTTOM`0F THE SOLAR MODULE FRAME ;SHALL'BE.'ATr,L AST'THE THE>ROOF:TO THE TOP^OF HE;ARRAY;I:THE MINIMUM,CLEARANCE'MAY'YE'REDUCED`TO 2'-- INCHES�BETWEEN' THE- VENT' AND THE ,a IN THE DIRECTION OF JHE ;SLOPE OF THE ,.ROOF,'' -THERE SHALL BE A GAR OFrAT LEAST CINCH BETWEEN MODULES THE ROOF SLOPE MUST HAVE A MINIMUM INCLINATION OF lOx OR THE PANELS MUST BE SLOPED AT A MINIMUM INCUNAT10N OF 10% PONRCE spy PV 4 PROJECT MANAGER: DESIGN: ]T )ATE 8/13/2009 T GRO.P. REST CASH CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. (30) FIRSTSOLAR # FS -275 BRUNNER, RALPH BRUNNER RESIDENCE 2.25 kW ROOF MOUNT PV SYSTEM SOLARCITY CANOPY -T 8" POST &RAIL 10210 STERN AVE CO210 STER CA. 95014 408-996-7066 ]B-9SO131 OO REV: _ (L) FRONIUS # IG 2000 (240) larCi 636-1029 MODULE VOLTAGE RATINGS Voc: 92 VDC Vpmax: 69.4 VDC *MODULE CURRENT RATINGS ARE SHOWN AS Isc AND Imp IN THE DC STRINGS IDENTIFIER OF THE SINGLE LINE DIAGRAM. (E) 200A MAIN ELECTRIC SERVICE PANEL MURRAY JA220VH (E) 20OA/2P MAIN CIRCUIT BREAKER #8 JUMPER (E) LOADS TO 120/240V SINGLE PHASE UTILITY SERVICE LINE DRAWING ri FIRSTSOLAR # FS -275 (30) PV Module; 75W, 72W PTC FRONIUS # IG 2000 ( 1 ) Inverter; 2000W, 240V, 50OVDC, 93.5% EFF. (I )SIEMENS # Q21515CT 15A 2—POLE PV BACKFEED Breaker; 15A -15A, Triplex (2x1 & 2 Pole) AC DISCONNECT PER ART. 690.17 (1)SQUARE D # DU321 Disconnect; 30A, 240V, NEMA 1 GEC ---------- I BOND (N) #8 EGC/GEC TO (E) GROUND ROD OR (E) GEC IN PANEL NTH IRREVERSIBLE CRIMP PER ART. 250.64(C) PRMCT uwnmr. low CROP. CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT RESI BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC. NOR DESIGN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE IT THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE DATE: CASH SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT 8/13/2009 THE WRITTEN PERMISSION OF SOLARCITY INC. UNBROKEN THROUGH EQUIP. (30) FIRSTSOLAR # FS -275 1 J AWG #10, THWN-2, Black 1 AWG #10, THWN-2, Red 1 AWG #10, THWN-2, White NEUTRAL 1 AWG #8, THWN-2, Green EGC/GEC 1 Conduit Kit; 1/2" EMT • Vmp = 240 VAC • Imp = 8.33 AAC SOLARCITY CANOPY -T 8" POST & RAIL FRONIUS 7t IG 2000 BRUNNER, RALPH (240) I 408-9967066 (12) AWG #14, USE-2/RHW-2, Black 14 BRUNNER RESIDENCE 2.25 kW ROOF MOUNT PV SYSTEM LOAD 1 AWG #10, lO 1 STRING (TYP.) 1 AWG #10, • Voc = 460 VDC \� ( 1 / AWG #10, • Vmp = 347 VDC ( 1 Conduit Kit; • Isc = 1.2 ADC C DC DC DC DC Dc • Imp = 1.08 ADC • Vmp = 6 ) AWG #14, USE-2/RHW-2, Block DC - C DC DC DC DC N� 2 STRING COMBINED (TYP.) °C • Voc = 460 VDC DC - • Vmp = 347 VDC C DC DC DC DC CMMM • Isc = 2.4 ADC °C' • Imp = 2.16 ADC ( I ) FUSIBLE COMBINER BOX 3 String, 60OV, NEMA 4 ( 2 ) NSI # IPL 4-4 Polaris; Multi—Cable Connector, 4 Port 3 ) FERRAZ SHAWMUTT # ATM4 EC; DC- Fuse; 4A, 60OVDC, Midget LINE (1 )SQUARED # Disconnect; 30A30A, 600V, NEMA 1 , BI—WIRED TO USE FULL RATING 14 BRUNNER RESIDENCE 2.25 kW ROOF MOUNT PV SYSTEM LOAD 1 AWG #10, THWN-2, Black 1 AWG #10, THWN-2, White \� ( 1 / AWG #10, THWN-2, GreerEGC ( 1 Conduit Kit; 1/2" EMT • Voc = 460 VDC • Vmp = 347 VDC • Isc = 7.2 ADC • Imp = 6.48 ADC PV 5 JB -950131 00 REV: — larCi Foster 6381029 1. Conductor Sizing per Art 690.8(8)(1) a. Conductor must have 30 deg. ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.16. c. Evaluate conductor temperature at terminations per 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current -1.25. All string terminations are rated at 90' C. 2. OCP Sizina per Art 690.80(1) a. Round up to next size per Art 240.4(B) 3. Conductor Sizing per Art 690.8(8)(1) a. Conductor must have 30 deg. ampacity x 125% of continuous current per Art 215.2(A)(1). b. Conductor must hove (after corrections for conditions of use) >= continuous current per Table 310.16. c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be x continuous currentr1.25. All branch terminations are rated at 75' C min. ------------------------------------------ 4. OCP Sizina a. Round up to next size per Art 240.4(B) 5. Conductor Sizina per Art 690.8(8)(1) a. Conductor must have 30 deg. ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.16. c. Evaluate conductor temperature at terminations par Art 110.14(C). Ampacity of wire derated for conditions of termination must be k continuous curent41.25. All inverter output terminations are rated at 75' C. 6, OCP Sizing a. Round up to next size per Art 240.4(8) 7. Conductor Sizing per Art 690.8(B)(1) a. Conductor must hove 30 deg. ampacity k 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.16. c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous curent41.25. All inverter output terminations are rated at 75' C min. -Ra T MANAGER: c CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT REST BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR )ES1GN: SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE IT THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE .ATE CASH SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT 8/13/2009 THE WRITTEN PERMISSION OF SOLARCITY INC. Module: 30 First Solar FS -275 72 Inv Pwr W PTC Voltage Drop Calculations Version 40 Inverter 1: 1 Fronius IG2000 93.5% .2,000 2,020 Length (ft) Vdrop Module: _ '�,'_�} String: 45 0,09% Inverter 2: .y,_; �- Branch: 55 025% Module: ! Inverter: 5 0-04% Inverter 3:_ _ _ �'�,_^_^�"� Combined: 0 0-00% Module: _ _ Total: 105 0.39% Inverter 4: Total: 30 modules. Total Inv Pwr _2,000 --2.0-2-01 PTC Photovoltaic Module Electrical Specifications: V Total STC-� I- -- 2,250 deg F deg C Voc= 92 Vmp= 69.4 V Record Low Temp: - - 116 8.8889 Isc= 1.2 A Max Average Hi Temp: 85 29.4444 Imp= 1.08 A Twc= -0.23 V/deg C Tsc= 0.48 mA/deg C String Type A and 2 Combined StringsType A Voc Correction Method IManuf Twc dE Branch Circuit Type A 5 modules per series string Fronius IG2000 Inverter Min Vdc Input. 150 Vdc Oisingle strings per branch 1 -way wire length: 6_5 ft 5First Solar FS -275 Voc= 460 V Min Vmp at Max Temp: 322;Vdc Max Voc at Min Temp: 499 Vdc _ 3 dual sMngs per branch Voc= 460 V Vmp= 347 V Inverter Max Vdc Input: 500 Vdc Vmp= 347 V Isc= 1.2 A 1 -way wine length: �_. 45 ft Isc= 7.2 A (the sum of the single and dual string short circuit current) Imp= 1.08 A Imp= 6.48 A (the sum of the single and dual string max power current) (cont= 1.50 A Art 690.8(A)(1) (cont= 9.00 A Art 690.8(A)(1) 1.a Try A AWG 14USE-2/RHW-2 at 90 deg C: Table 310.16 3.a Try IC AWG 10 THWN-2 at 90 deg C: Table 310.16 1 String 2 Strings Icons • 1.25 = (Amps)1125 Icont ' 1.25 = (Amps) 1.88 3.75_ 30 deg Campacity = 401 30 deg C ampacity = 25(� 3.1a Icont= (Amps) Startampacity 9.00 40 1.b Icont= (Amps) t.50 - 3_00 Start ampacity 25 Temp, Berate (%=F) 0.58 0.58 Temperature derate O =F) Cndl. fill derele (%_#) 1 Conduit fill derate (%=#) 0.5 Derated ampacity 23.2 Derated ampacity 7.25 Term 1 Tenn 2 Temp table 75degC 90degC 1.c Iconl'1.25= (Amps) 1.88 3.75 3.c Icont'1.25= (Amps) 11.25 11.25 Ampacity 25 Ampacity 35 40 2 (cont' 1.25 = (Amps) 1.66 3.751 3.d OCP size = 1 121 OCP size = I 2 4 Combined Inverter Output Service Voltage= 240 Volts Inverter Type A Output Total Inverter Power- 2,000 Watts 1 -way wire length: E0 ft Fronius IG2000 1 -way wire length: OS It Icont = # of inverters max inverter current Art 690.8(A)(1) (cont= I 8.331 Art 690.8(A)(1) Icont = (Amps) 8.33 4 Iconl'1.25 = (Amps)IF 10.42 A Art 690.8(8)(1) 6 ]cont •1.25 = (Amps)' A Art 690.8(8)(1) OCP size = I 75�A Art. 240.6(A) OCP size = _10.42 151A Art. 240.6(A) 5.a Try IC AWG 10 TiWN-2 at 90 deg C: Table 310.16 7.a Try IC AWG 10 THWN-2 at 90 deg C: Table 310.16 10.42 (cont' 1.25 = (Amps) Icons' 1.25 - (Amps)10.42 30 deg C ampacity = 40 30 deg Campacity = 40 5.b Icont= (Amps) 7.b Icont-(Amps) 8.33'•Start ampacity Start ampacity 40Temperature derate (%=F) 036.4 Temp. derate (%=F) 0.91Conduit fill derele (%=#) Cndt. fill derate (%=#) 1Derated ampacity Derated ampacity 36.41 5.c Icont'1.25=(Amps) L 1_0_.421 7.c Icont'1.25=(Amps) 1 �I�!F.-' /�\I{ Ampacity 35 _10.42' Ampacity 35 I{ ( I rc, (30) FIRSTSOLAR # FS -275 SOLARCITY CANOPY -T 8" POST & RAIL # IG 2000 BRUNNER, RALPH 10210 STERN AVE CUPERTINO, CA 95014 (240) 408-996-7066 PV 6 BRUNNER RESIDENCE 2.25 kW ROOF MOUNT PV SYSTEM III NUMBER JB -950131 00 REV: - rCi 393 Vinbgo Pork Drlv4, Suite 140 Foster City, CA 94404 T:(650) 630.1028 1 F7(650) 638-1029 First Solar's FS Series 2 PV Modules represent the latest advarcements ir. IFimfilm solar mryhde twhmrlogy. The Series 2modules are. IEC 61646 and Safety Class II SK III cl ilied for use in systems op to 1000 VUC. Hrst Solar prwides costa I lective Fin -film module solutions to leading Solar project developers and system integrators tar large stale. grid corrected solar posver plants. First Solar applicauan engireers provide technical support and comprehensive product documer,ta6oc to support the design. irstanalion, and Torg term operanors of high performance PV systems. fmmcal Sin Mia Pan WARRANTY • Ma-erial ed mrkmarship vsha arty far five 15) fears arc a oovve• a-tpmV rrsl of W% of the nominal olui pmver;zd-g (P,a, N- 5%) during the first tan 00) years a -d 80% during nul. . rue (25) years sul .a :he visummy ;errs and comitio-s. • Modules are lite Lyclec wriaged wain a Lolletdo: znd Hecydinc Prog-am, painting module ow-ers what he cast preifunded erc o .1i',e take back and recycli-g of the modules. Fila Solar (US] Firs Salm IEumtrel Tel 4i-602-414-9300 Tel #491016731 1443-0 Frst Solara Email: iihit0i nsolarcom Erraii wriglislsGarde Fri '4 w oznr.pa, web'. vw.w.'irmmL;umrr wen'. www.irssnarca PV MODULE m ELECTRICAL SPECIFICATIONS Vdu9eetP„'-_` aV.W JE_ 67,T-_. ..67.9_'•_69.4'x, -,709_-]C71.3_ - -:CunmlelPZ -""1C6cu �i7, .161' 1.07:,--,108�j`7® �CCI2 ciroavmay-:.;YsM 5_89 9a- 'Shml Gnril Cumvll;'_ .,--'SIaW: �': 1.191 ', 1.19. _120:' 121. x_121 Maximum Systan Volupe„V;pyf It_ =� _ '- 1000 ,irmq -aloe PaelydsntW Perr.` �TkAipuILli._. : (1) FRONIUS # IG 2000 (240) '4cmpciatum CulficimldVz:;ILNa1.-.:YL''.- '” 0259e/;C:__�.._- .aempemNreCdeliuentdlr1004%f,L [_ Uatin9 R—w O�__ WIAI_�r_-;,_. __.-- -mrni Jt_ �Nopirial � Ic/s%I _-7CP,,;�Iwl'Cszs='C54 e .,C s63=,G s>.a �Cw.a� [volla9e afF,,, 'tveWM:7Cw'_Ir-64...Cw=��=w.-_7;`67_' [Omen) dl Pm____;I�fA)]C0.®-1._,0 e5�_O.fiS-1C087 �C0.90� LOwSc�uTn Voltage__�::�sMCCas=Ces�Ce6_�e7�Ce7� [Shen Orcvil llmm=—;IoW �I_096, JC,096�ro87_LI00 __ 1.g1� re MECHANICAL DESCRIPTION vi 12,70rrm _ ■Rlakr la66mm— YridN - I fi00mm - _ _7Arp�1�072rrc� 06iiewms SuLi WI 00i LDim Diudc-" Norc CCA Typ�rG_ srdTe semiaNunw. I Ifi_niva cells [Erase Mamr�l: Nmc Cont Type "31mm Ma tmrrgNaedhom9lass I IammalN to 32mm tenpered back glass [Eopsolalion EVAIFdylYer Amam iN odgc ml Elrvsey, at 2111hiMi ISSeat 2 meds amaiemm sm irmssee n linden d 296 it 200w/m' el-.-- m Matteis M1W05Y/m'. Mrmis ApolYzum Nate PD64201w muded amlps of the amforrnhem al Ion lwileseds M hh"s.7 in, uNam semri a mhemis. 5prilimliens she sv?r[I to ease ® �$I•TWCimt l.adlrn-s ISTCIIWN/N.I,M Li. ]SC ' 1hv lamdue sped0ta i- CN50'®0. Sado, 361 is devgad lor;rystellira elicao epauletlhaAi d tha:0=11guavax cl Hill rib mocks, oxuase s \ sduge a�d tuner lesels are rxuiJ to iad¢erevrnc.•rcnu i, Ila maLles. :etM14y n no]We te,eeatures Revvse of xCevonc Iromlal ape min rages a tae^ ` IxnlarlinxsrlxMxlp cerml R,tlus,lhx In torp lm lfe me'6odilx is rlr�.7Vlar alvei ran the fort rcguire.+am la calx rweralim of l'e+mdde P7s4:1,7 N trMa Pb, E 610mm cekla 4 8 5esiWe, maplle4 raeinin9 d'm e T, 4 mmunna p s 600.L-079mm http://www.firstsoIar. am= rCi 393 Vintage Park Drivo. Suite 140 Fodor City, CA 94404 T:(650)638-1026 I F:(650)636-1029 (881IFSOL-CITY (765-2489) 1 www.solarcity.com PV 7 aROJECT MANAGER: )ES1TN: 3T )ATE 8/13/2009 REST CASH CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. (30) FIRSTSOLAR # FS -275 BRUNNER, RALPH BRUNNER RESIDENCE 2.25 kW ROOF MOUNT PV SYSTEM SOLARCITY CANOPY -T 8" POST &RAIL 10210 STERN AVE CO210 STERN CA 95014 408-996-7066 JOB NUMBER: JB -950131 00 REV: : (1) FRONIUS # IG 2000 (240) am= rCi 393 Vintage Park Drivo. Suite 140 Fodor City, CA 94404 T:(650)638-1026 I F:(650)636-1029 (881IFSOL-CITY (765-2489) 1 www.solarcity.com INVERTER COPY PRo,ECI MANA(iit: CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT '"" FS (30) FIRSTSOLAR H -275 REST BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC. NOR DESIGN: SHALL T BE DISCLOSED IN WHOLE OR N PART TO OTHERS OUTSIDE IT SOLARCITV CANOPY -T 8" POST l9 RAIL THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE )ATE -FRONIUS IG Ro eee ooe ee DC Dale WW FAONIIIB 107000 P10NIU51O ]WO RIONIU51075W-LV RanmrtloMatl Wpower 1500-2500 wp 2600-3300 Wp tB00-3000 Wp Max. DC w VTmd 500 V 500 V 500 V Operating OC villa erange 150-150V I50 -450V 150-450V Max. usable DC input wrrenl 13.6 A 18A 16.9 A I AC Oulpul Dab FRONIUB IG 7000 P10NIUB IG 3000 PtONIU8IG 7500-1Y Maximum OmpN power 040' C 2000 W 2]00 W 2350 W Normnal AC outpin wingp 240 V 208 V Utaty AC vd 212-264V 40V •10%/-12% 183-22]V Masvmvn AC amaB 835A 11.25 A 11.25 A MaiMian umny bock food saran 0.0 A 59.3-60.6 Hz BO its nom 2 Trial Hamnlic Oismrlgn THO <5% 8 Power Factor copN)s 1 1 General Date FIIONIII3IG' 0 FAONIUS IG 9000 FAONIU6 W 7500-W Max. eBN.iaay 10 PFamlma Statlatl0FRCE Consanpum M abntl-by < 0.15 W (night) during ion 7 W E3 EnrJosae NEMA 3R p Sire 9xwxn) 18.5a 16.Sa B.BIMws (4]Oa418 x223 mm1 i Wei 26 Has. (11.8 Ambient tenevermhav raw -5 b 122'F -20 b X50' E COd' Opnhd19010rC¢E rmLldlOn I AC anal DC dsconrrecls sbrpmtl UL OC 8 AC 6sconnects e Noto<tlma e Grouts bun protection IMamel GFOI. In eccortlanco wlm UL 1741 OC reverse bctlan polanty InlmWtlbtle L4ertlug Prmaelfon trRmv41, in BCm�dM® with UL 1741, IEEE t54] Ower oenpormum, Wmltl Power uaa0n9 EE Internal OC 8 AC Tealatl l0 8 kV 8B sqqe swety UL 1741 8� EMI FCC Part 15: Class A 8 B e= ig Amiblattltrg laotostmn UL 1141, IE1� 154] (aYamO faun tlmactar etttl Immo wNl NEC Art. 690 . UL.I 741 fi MbwOareats ae MNtimum AL ova utarenl pnotecUm Two- , 15 / 20 A draril blaNa AC w+re saingviernonty Use maaiman AWG 6' 194'F copper vine DC wan sizing Use niatineon AWG B tBd•F 01B'CI m Pa wtro AC msmtnen 16A ppEa DC mscaentl 25A E year 3 EE _ a Distributed by ®' - ^E Froniue USA LLC Bolan Elecbonic OiWsion 10421 Chatlon Orive Sube 1100 Brighton, Mi 48116 Plane: 810-220-4414 Fax: 810.220-4424 E -Mail: pv.usOlmnlus.wm e www.honlua-uea.eom A GO COPY PRo,ECI MANA(iit: CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT '"" FS (30) FIRSTSOLAR H -275 REST BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC. NOR DESIGN: SHALL T BE DISCLOSED IN WHOLE OR N PART TO OTHERS OUTSIDE IT SOLARCITV CANOPY -T 8" POST l9 RAIL THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE )ATE 10 PFamlma Statlatl0FRCE CASH SALE AND USE OF THE RESPECTIVE SOLARgTY EQUIPMENT, WITHOUT (1) FRONIUS H IG 2000 8/13/2009 THE WRITTEN PERMISSION OF SOLARCITY INC. Pv Id ft IN dil CUSTOMER BRUNNER, RALPH BRUNNER RESIDENCE 8 , Solaircl JOB NUMBER 2.25 kW ROOF MOUNT PV SYSTEM 10210 STERN AVE 393 vivbev Park Dino, 5uit0 140 CUPERTINO, G 95014 ) JB -950131 00 Foster City, CA 94404 ( 240 408-996-7066 REV: — T:(650)63B-1028 I F:(650(638-1029 (888) -SOL -CITY (7 65-2489) I wwwsolorcity.con MOUNTING HARDWARE The Canopy T -series system optimizes strength, performance and aesthetics by structurally attaching solar modules to roots covered with flat cement files or Spanish tiles. 6000 series aluminum otters superb structural and fatigue strength plus excellent corrosion resistance even in maritime environ- ments. Dead -soft 3000 series aluminum flashing with an EPDM collar provides convenient and ex- cellent long term waterproofing. • Precision engineered base track provides flexible positioning of mounting pml minimi2ingsize of penetration and exposure to elements. • 6061-T6 alloy offers excellent structural and fatigue strength. • Design reduces part count. • Wind uplift strength rated at 390 pounds (max 300 pound dead load). • Superior torsional stiffness and high lateral load carrying capability. • Dual lag boll mounting option allows for flexible fastening options to accommodate local load conditions. OB Canopy -T Track © Track Bolt OPosl 4" or 8" O Lag boll washer (2) O Lag bolt (2) OFlashing (not shown) �eee -�-solaicity. m 888 -SOL -CITY 1888.765.2489 I WWW,SOLARCITY.COM SolarCity Canopy T -Series Installation Instructions Approved mounting method: 1. Remove tile in area where penetration is required. 2. Locate rafters. 3. Drill pilot holes into rafters. 4. Mount base track using two (2) 5/16" by 2 112" long lag bolts with washers. 5. Tighten bolts to 15 n -Ib. 6. Mark where track intersects with peak of tile. 7. Drill rile with carbide tipped I -y" hole saw. 8. Insert track bolt in track approximately below peak of tile. 9. Insert tile and engage the threaded hole in post with the back bolt through the hole in tile. IO.Tighten post to 5 ft -Ib by hand. 11.PIash in accordance to local building code. February 2009 i 6vies Reil I 16 Cd1,1,h11001; 2009 Sp 3Cda 0dlraralian, All r,ts resrvea. SoWQ, aid N, Solat, --o n dr- aria, tix lrademzrks 015o:a'Up Co¢Mt m. PV 9 ROECT MAractTt: DESIGN: IT DATE: 8/13/2009 RESI CASH CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENERT OF ANYONE EXCEPT SOLARCITY INC. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. w (30) FIRSTSOLAR # FS -275 W BRUNNER, RALPH BRUNNER RESIDENCE 2.25 kW ROOF MOUNT PV SYSTEM SOLARCITY CANOPY -T 8" POST &RAIL 10210 STERN AVE CUPERTINO, CA 95014 4oe-996ao6e due Numum JB -950131 00 REV. _ (1) FRONIUS # IG 2000 (240) FMCE COPY larCi Foster City, CA 94x04 6381026 I F:(650) 638-1029 44