09120038 CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 1026 PENNFNGTON LN CONTRACTOR:SOLARMASTERS,INC PERMIT NO:09120038
OWNER'S NAME: RUDY MICHAEL GOTTALD 25125 SANTA CLARA ST STE 254 DATE ISSUED: 12/15/2009
OWNER'S PHONE: 4082525229 HAYWARD,CA 94544 PHONE NO:(510)583-1300
❑ LICENSED CONTRACTOR'S DECLARATION r r r
BUILDING PERMIT INFO: BLDG ELECT PLUMB
License Class A-6 Lic.q
c MECH r RESIDENTIAL r COMMERCIAL r
ContractorIA,6 Date J2/sem
1 hereby affirm that I am licensed under the provisions of Chapter 9 JOB DESCRIPTION: INSTALL PHOTOVOLTAIC PANELS(20)ON EXISTING
(commencing with Section 7000)of Division 3 of the Business&Professions RESIDENTIAL HOME,3.6 KILOWATTS
Code and that my license is in full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
I have and will maintain a certificate of consent to self-inswe for Worker's
Compensation,as provided for by Section 3700 of the Labor Code,for the
performance of the work for which this permit is issued.
I have and will maintain Worker's Compensation Insurance,as provided for by Sq,FI Floor Area: Valuation:$2000
Section 3700 of the Labor Code,for the performance of the work for which this
permit is issued.
APN Number:36203031.00 Occupancy Type:
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is
correct. 1 agree to comply with all city and county ordinances and state laws relating
to building construction,and hereby authorize representatives of this city to enter PERMIT EXPIRES IF WORK IS NOT STARTED.
upon the above mentioned property for inspection purposes. (We)agree to save
indemnify and keep harmless the City of Cupertino against liabilities,judgments, WITHIN 180 DAYS OF PERMIT ISSUANCE OR
costs,and expenses which may accrue against said City in consequence of the 180 DAYS FROM LAST CALLED INSPECTION.
granting of this permit. Additionally,the applicant understands and will comply
with all non-point source to per the Cupertino Municipal Code,Section �7
Issued by:1���---" Date:/2�f
Signature Dale .C- (J�
❑ OWNER-BUILDER DECLARATION RE-ROOFS:
All roofs shall be inspected prior to any roofing material being installed. If a roof is
I hereby affirm that l am exempt from the Contractor's License Law for one of installed without first obtaining an inspection,1 agree to remove all new materials for
the following two reasons: inspection.
I,as owner of the property,or my employees with wages as their sole compensation,
will do the work,and the structure is not intended or offered for sale(Sm.7044, Signature of Applicant: Date:
Business&Professions Code)
I,as owner of the property,am exclusively contracting with licensed contractors to
construct the project(Sec.7044,Business&Professions Code). ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER
1 hereby affirm under penalty of perjury one of the following three HAZARDOUS MATERIALS DISCLOSURE
declarations:
I have and will maintain a Certificate of Consent to self-insure for Worker's I have read the hazardous materials requirements under Chapter 6.95 of the
Compensation,as provided for by Section 3700 of the Labor Code,for the California Health&Safety Code,Sections 25505,25533,and 25534. 1 will maintain
performance of the work for which this permit is issued. compliance with the Cupertino Municipal Code,Chapter 9.12 and the Health&
I have and will maintain Worker's Compensation Insurance,as provided for by Safety Code,Section 25532(a)should 1 store or handle hazardous material.
Section 3700 of the Labor Code,for the performance of the work for which this Additionally,should 1 use equipment or devices which emit hazardous air
contaminants as defined by the Bay Area Air Quality Management District I will
permit is issued. maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the
I certify that in the performance of the work for which this permit is issued,l shall Health&Safety Code,Sections 25505,25533,and 25534.
not employ any person in any manner so as to become subject to the Worker's "
Compensation laws of California. If,after making this certificate of exemption,I Owner or authorized agent:
become subject to the Worker's Compensation provisions of the labor Code,l must Dale: 57
forthwith comply with such provisions or this permit shall be deemed rooked.
CONSTRUCTION LENDING AGENCY
APPLICANT CERTIFICATION I hereby affirm that there is a construction lending agency for the performance of work's
I certify that I have read this application and state that the above information is for which this permit is issued(Sec.3097,Civ C.)
correct. I agree to comply with all city and county ordinances and state laws relating Lender's Name
to building construction,and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes.(We)agree to save Lender's Address
indemnify and keep harmless the City of Cupertino against liabilities,judgments,
costs,and expenses which may acerae against said City in consequence of the ARCHITECT'S DECLARATION
granting of this permit.Additionally,the applicant understands and will comply
with all non-point source regulations per the Cupertino Municipal Code,Section 1 understand my plans shall be used as public records.
9.18.
Licensed Professional
Signature Dale
CITY OF CUPERTINO
2 ITEMS OF 2 PERMIT RECEIPT OPERATOR: patg
COPY # 1
Sec: Twp: Rng: Sub: Blk: Lot :
APN . . . . . . . . : 36203031 . 00
DATE ISSUED. . . . . . . : 12/07/2009
RECEIPT #. . . . . . . . . BS000009345
REFERENCE ID # . . . : 09120038
SITE ADDRESS . . . . . : 1026 PENNINGTON LN
SUBDIVISION . . . . . . .
CITY . . . . . . . . . . . . . : CUPERTINO
IMPACT AREA . . . . . . .
OWNER . . . . . . . . . . . . : RUDY MICHAEL GOTTALD
ADDRESS . . . . . . . . . . : 1026 PENNINGSTON LANE
CITY/STATE/ZIP . . . : CUPERTINO, CA 95014
RECEIVED FROM SOLARMASTERS, INC
CONTRACTOR . . . . . . . : ARNOLD LOWENSTEIN LIC # 31250
COMPANY . . . . . . . . . . : SOLARMASTERS, INC
ADDRESS . . . . . . . . . . : 25125 SANTA CLARA ST STE 254
CITY/STATE/ZIP . . . : HAYWARD, CA 94544
TELEPHONE . . . . . . . . : (510) 583-1300
FEE ID UNIT QUANTITY AMOUNT PD-TO-DT THIS REC NEW BAL
---------- ------------- ------ --- ---------- -------- -- ----------
1BCBSC VALUATION 2, 000. 00 1 . 00 0 . 00 1. 00 0 . 00
1SOLARRES FLAT RATE 1. 00 207. 00 0 . 00 207. 00 0 . 00
---------- ---------- -------- -
TOTAL PERMIT 208 . 00 0 . 00 208. 00 0 . 00
METHOD OF PAYMENT AMOUNT REFERENCE NUMBER
----------------- --------------- -------- --
CHECK 208 . 00 #5007
---------------
TOTAL RECEIPT 208 . 00
VOICE ID DESCRIPTION VOICE ID DESCRIPTION
--- ----------------------- -------- --- ------
301 ROUGH PLUMBING 303 ROUGH MECHANICAL
304 ROUGH ELECTRICAL 313 ROOF NAIL
505 FINAL ELECTRICAL 507 FINAL PLUMBING
508 FINAL MECHANICAL
09
CITY>OF- CUPERTINO
SOLAR PANEL
- PERMIT APPLICATION FORM
CUPERTINO
APN # oZ C7 3 Date:
Building Address:
oar
Owner's Name: Phone#:
R04) y�i�/��L Ga70L�1-0 �/G,a ,Sz29
Contractor: = Phone#: -fi58 757-767 Contractor License#:
Fax #:/ _1n-11.111 `l o-1893
Contact: 4, 4aZ4 2-0W4V14r70;'A) Phone#: /a 9 Wy Cupertino Business License#:
Fax #: 3/ 50
Job Description:/",//
Residential Commercial 0 Number of Panels/Units: o?O Kilowatts: -3.(0
Valuation cost ofproject): a2 6,00 —
Project Size: Express [= 'Standard LJ Large LJ Major
Green Points:
1.2 KW-6 Points 0 2.4 KW- 12 Points 3.6 KW- 18 Points
Quantity Fee ID Fee Description Fee Permit Type
Group
I SOLARPANL Commercial.Solar Panel E SOLAR-COMM
1PHOTOVCOM Photovoltaic System E
Commercial/Multi-family
1BSEISMICO-. Seismic Commercial E
I ELCPLNCK Plan Check Fee E
0 1BCBSC Cal Bldg Standards B ALL PERMIT TYPES
Commission Fee COMM & RESID
I 1SOLARRES Residential,Solar Panel E SOLAR-RES
Revised 08/20/2009
LOAD CALCULATIONS
1026 PENNINGTON LANE
oven 3400 V A
cookttop 7700 VA
fridge 650 VA
washer 1000 VA 1
dryer 600 VA
2400sq ft 7200 VA
total 20,600 VA
first 10,000 at 100 % =10,000 VA
10,600 at 40 % =4240 VA
total =14,240 VA
A/C 100% =3200 VA
total: 17,440/ 240v = 72.67 amps
i
oonan'R ' Falnvoods UK
SUB-PANEL AND AC DISC �� �a�; 1 as
,Main Meter jMcClellan Rd Mcdeaan RdL
�� - - tI-
�
It
R -
y6_.
Il ' eswo` ✓ \'
gill
' ; ` 2a2vF,ca4� lJuc Wa I 11
,/ ;• ® ert .a. t.Oiynn 'Hu Ln
O
YPDe
'lol! man er
Proposed location of 20111M ' ENT
roof-mount Suntech I ` ; } 7 ` 7=� 4 t �C
Solar modules. �°111,101 '�vl
°
1 , r - .Columbus Ave = / L
Ems
. .`CWIemn:; t,
ra
i�
o intsbire St- -
o a . .
'N0iion81SN(RTE CATION
O V.NIunO VIl �� tl 1801 - Scale)T=600' G
/��ttl Y
I
o NO NdIN3b I'HS�r. I;�'dl.d.SIHl
c
0
` JAN 0 5 2010
Entrance
Garage Entrance
N®WUH LJJ
0
° C �1
U o � ShedrPRR ..:
• : - Plot Plan
Site Loeatim
' Rudy Gottwald
91 i.
Pennington Ln. ► SITE PLAN 1026 Pennington Lane Cupertino, CA. 95014
Scale 1•=10' Sizo: Drawn by Rep: Job No.
' B Tony Cervantes
25125 Santa Clara SL Scale: D.t. 1 Revision: Sheet:
Ha ard, CA.94544 Indicated 5/12/09 1ors
Noonan Qi fr. a tFalnvaods Ct
Proposed location —+ ar es
, Q
of Inverter .Main Meter McClellan Rd, i _— __ -�� McClellan Rd
—J Uly Ave
���\
Gr v;`
L1 01
CI 3 S
V11V I ParkvQaJ ' Po9° — ?J _Enn_Way_ `
l Y _°s Presda or �Wa ��-- � — ll, tunvm Ln
1 1
.;� `1 mea++a ��r way��l _ I e,� ^' nn on Dr �\ L 1 ��' ,OI maul Ln l'J`
•, Or ® Ma sP J I _
r rfyinmsitortor /I�.— n �; .i 1". _ I l D,
I_
Ln
o o
l� l� l� o , s t` �� G� Tei na.k
Y
De U
All
Proposed location of 20 s , t S
roof-mount Suntech �! !! „ • �� � 1iAl It � L 1 ' -- _
Solar modules. o / , ��rr ,. �q —SB -� Columbus ave r oOo
G!. 1e nil �Ir i ll r� d���� ea:ue<on sc
� l
1t9. I I� ti• h
C
a
o c IN ACCORDANCE W TH THE CITY OF APPROVED
-SITE LOCATION
CUPERTINO CODES AND ORDINANCES -
�.�%`- j2 L1 (� Scale i'=600'
DATE
SIGNI •
this tans and spec)rca ions USt
7T
F
be If a job at all times and it is -I dl1 I W 8 n S
uhWwlul tom changes or alterations �
on same without permission from ��
the Building De rtmen , of Cu rlino. �
The stamping or this plan an • iticatiohs (' T'1
SHALL NOT be held to permit or an 1�jY
Entrance epproval of the violation of any pmv s I V
of any City Ordinance or State Le W. �_ �C�
Garage Entrance p9
I
0
VV
e a {7.Y•.
Q o SMet Pmn
o'
• . - Plot Plan
!° I . r
resideouS m Loouon
I. Rudy Gottwald
Pennington Ln. ► SITE PLAN h 1026 Pennington Lane Cupertino, CA. 95014
Scale 1"=10' 1.888 757 Szc:77. Drawn by: Rep: Job No
B Tony Cervantes
25125 Santa Clara St. Scale Dam: Rowson: Shoot
Hayward,CA.94544 Indicated 5/12109 +o17
Notes Array System
1. Key Manufacturers are: Sunlech-Power Modules I F Enphase Enregy
• Modules: Suntech Power10 MC190-72-240-S11t2 •Elea,ical Spodrealions
71 Stevenson Street, 10th Floor. Micro-Inverters per branch -IEC 61215.IEC 61730
Microinverter Technical Data
Circuit @ 240VAC -Class C Fire Rating M190-72-240-S1%z
San Francisco, CA. 94105 h Max Array Input Power(dc@stc)230W
•TIV Sala Class II Certified
C (2600WAC) 5TPI80S241Ad Max DC Voltage 54V
• Inverter: Enphase Energy _ _ �^r^tl poner.mm Peak Power racking Voltage 22-40V
list
_ _ 'I DC Max.Input current 10A
201 1 Street, Suite 300 — -- TSTC emperature
(Standard Tectum Miomltoop Wm2.25oC Call P
� Tempamture AM 1,5 spectrum Minimum Spocifiad Power Raring DC Max.short circuit CUmentl2A
Petaluma, CA. 94952 Q O O is 3%Below Pp,other specifications aro•1-10%Specifications Number of Fuses String Inputs
to change without notice.25 year Limited power warranty AC Maximum Output Power 19OW
1 Module efficiency calculated on Pp and module exterior AC Normal output cuu ant 800mA
O dimensions, Power factor>0.95
p
2. All com onents are UL listed and CEC certified, are PTC Rating(W)162.5
� Pmp(W)160 Maximum units per branch 15
warranted. p 10 MC190-72-240-S7112 Vint,(V)36o
Micro-Inverters per Imp(A)5.0 Peak inverter efficiency 95.5%
3. The solar PV system will be installed in accordance p Vp<w)4xa Nominal Med tracking 9.6%
branch Circuit @ Isc(A)5.29 Nominal MPP tracking 99.6
with Article 690 of the 2008 NEC. 240VAC(2600WAC) Cell 72
`_ – Maximum Series Fuso 15A
4. AC disconnect . — — UL Rated System Voltage BODY Date Sheet Attach
5. A grounding electrode system in accordance with NEC ti =_________ TIV Rated System Voltago 1000V
690-47 and 250-50 through 60 and 250-166 shall be —O ° =�
provided. Grounded do Photovoltaic arrays shall be I �#10 USE-2  ground Solid Copper �1
ground-fault protection meeting the requirements of All grounds and neutrals bonded u®
690.5(A) through (C) to reduce fire hazards. Ungrounded .I-box #10 THNN or 4-10 MC  Ground #8 THNN  ground through here to existing
arrays Shall Comply with 690.35 Per NEC, grounding in 3/4"or larger conduit in 3/4"or larger conduit grounding conductor
electrode system of existing building may be used and ���8®�
bonded to at the service entrance. If existing system is
inaccessible or inadequate, a supplemental grounding
electrode will be used at the inverter location consisting of 1 15A 2 pole breaker per.string 100A$efVlCe Entrance
a UL listed 8 ft ground rod with acorn clamp. Grounding T 1 of z Intermodule wirin =DuraSheat6@
9—
electrode conductors shall be no less than #8AWG and no Low-voltage Power, Unshielded;
greater than#6AWG copper and bonded to the existing I I 60A I o EPR,•HYP,volts: 600V, UL Ty
KWH pe
grounding electrode to provide for a complete system. z Pole RHH/RHW-2/USE-2, conducton �
• t15A' It. .: Size(AW
10, Conductor
30A Breaker
6: Direct-Current Rating. Overcurrent devises, either fuses c A 30A = i '
Strands:7/.0612, Rated at 900C
or circuit breakers, used if any do portion of a photovoltaicLLL wet or dry with Multi-Contact
power system shall be listed for use in do circuits and connectors
shall have appropriate voltage, current, and interrupt _� Intermodule ground=#8AWG solid
ratings. ECEI��d�
7. The Photovoltaic disconnecting means shall be 60A sub-panel 30A Ac disc =_
installed at a readily accessible location either on the Square D or Equivalent Squared D or equivalent WARNINGI Xiu o
WARNING Exterior Exterior ELECTRIC SHOCK HAZARD PANEL MAY BE ENERGIZED BY
outside of the building or structure or inside nearest the ELECTRIC SHOCK HAZARD -DO NOT TOUCH TERMINALS-D •UTILITY OR CUSTOMER
-0O NOT TOUCH TERMINALS- TERMINALS ON BOTH THE LINE ----"AERATOR
point of entrance of the system Conductors. TERMINALS ON BOTH THE LINE ANDTHELOADSIDES MAY BE
AND THE LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION
8. The Program Administrator will be notified prior to use ENERGIZED IN THE OFF POSITION
SOLAR PV SOURCE
and activation of any solar installation. System will be 200 VAC OPERATION VOLTAGE
PHOTOVOLTAIC 1ZA MAXIMUM OPERATING
commissioned by owner per utility interconnection AC DISCONNECT Label CURRENT
agreement. Revised 12/21/09 Shear Plan
1.System will have 60A Label
Sub-panel rated Nema 3 1 - 0 4 • Electrical Plan
A
TAIC AC PHOTOVOLTAIC
2. 30A AC disc rated
POWER SOAK ' ' Site Localian
Nema 3 Operating Current(Imp) 11.23A
'` Rudy Gottwald
Operating Vdlage(Vini 18,V 1026 Pennington Lane Cupertino, CA. 95014
3. 30A 2 pole breaker at Maximum System Voltage(Voc) zary
SefVICe
Sheri curtant(ISO 12.2A Sad I Drawn by: Rep: Job No.
B Tony Cervantes
25125 Santa Clara SL scale: Date: Revision: sheer
Hayward,CA.94544 None 5/12/09 2of3
/ Module
Inter-Module Clamp
-1 —
1 ---
_t
14-6" -------------------------------- _♦ -----------_ ___. Grad Nut - —
1
• —Strut(to Create grid pattern)
------------------------------ - - 3/6"Bolt/flat Washer
Galvanized Flashing.12112 x
�A� 8314-base,No-Calk collar
24• I \i--\ SIS Fast-Jack Stand-Off
Composition Roof 1
Shingle
m.
Wootlen base roo
C
s'
t
5116"x3"LAG BOLT -
C r.
1. Standard wood truss construction, 2x6 rafters 24" O.C. to form
gabled roof, sheathed with 1/2" plywood. Upper surface of plywood
faced with felt paper. Finished roof surface is Shingle. C
2. Mounting system to be attached to 3x6 rafters at 4' to 6' 0.C.
depending on rafters location. }
3. Lag bolts are 5/16" x 3" stainless steel. (See attached cut sheets) 71 T
4. Roof penetrations are sealed with Sikaflex1A sealant and are
guaranteed for ten years.
F .
BYIZF
025 Sheat Plan L
- Mounting Plan
� � SiteloationRudy Gottwald
1026 Pennington Lane Cupertino, CA. 95014
bK Rap: Job No.
Tony Cervantes
5 Santa Clara SL scam: Dale Rapson: spaceward,CA.94544 None 5/12109 3.13
MW
N SUN d ECHertiftatidns
Certifications UL listed(UL 1703)_
S'TP170S -24/Ab- 1
STP160S-24/Ab-1 STP165S-24/Ab-1 High Efficiency, High Quality Module Diagram
STP175S-24/Ab-1 STP180S-24/Ab-1 PV Module
Specifications
Suntech's.STIPWT is designed, and built to deliver highest
efficieficy and reliable power for onj. rid reside mial and commercialCell Monocrys'alline silicon solar cells
___ __ 125 .-125Animsbagamaggh ""i E991%
systems worldwide. Relying on Suntech's well-known stringent
mm m
No.of cells and connections 72(602)
BEENE manufacturing -standards and latest PV technology, the module 011110116ol•' Dimension of module 1580mm-808mmx35mm
provides the highest possible artargy,output per Watt with total "40° Weight i5.5kg
WIDE an
module efficiency of 14'.1%- Supe: r conversion rate and;excep.
no
tional 16w-light performance enable it .16' dea[ with-the most Ron mom! Series Fuse Rating 15A
installations. The module is the perfect choi6e for those MOMEMN
who demand outstanding performance and exceptional uniform At j A Temperature Coefficients
(Back View)
NOCT 45°C t2C
A99111, Short-circuit current temperature coefficient 0.017%/K -,C, f
Features and benAits
MEN an
iam 1
Open-circuit voltage temperature coefficient -0.34%IK � •'
_ Peak power temperature coefficient -0.48
•• - - Power tolerance 13%No MEMO
m High transparent low-ironj tempered glass dollno o�
- IdOCT:Nominal Operating Cell Temperature
T Unique techniques give the p�nel 4 following features: esthefic M - seauo A-' — dam refer to STP165S)
appearance. with stands high wind-pr6ssure-an&snow load, and dill
MEMO
�.
taasyinslallation man
im I
y .and nique technology ensure that problems of �vat�ir freezirf
warpingI occur
.. no - Output
- - - .- - - Cable AIW(72AWG)25 year power output warranty
Note:imnpnch) s��
.. - / U, .., / ' - Lengths 1200mm(-)and 800 in(-)
L r o L�„�S l �� , - r - t - - Connection MC Plug Type IV �1
Electrical Characteristics Characteristics Normalized Isc, Voc, Pmax vs. module
Model STP7803-24/Ab-1 STP175S.24/Ab-1 STP1705.24/Ab-1 STP1853-24/Ab-1 STP1603-24/Ab-1 Module lVGraph 170W temperature characteristics r
Open-circuit voltage(Voc) 44.4V 44.2V 43.8V 43.6V 43.2V !--•-�•
Optimum operating voltage(Vmp) 35.6V 35.2V 35.2V 34.8V 344V
ro
• Short-circuit current(Isc) 5.4A 5.2A 5.14A 5.04A 5A ; % m
F a us p�7
Optimum operating current(Imp) S.OSA 4.95A 4.83A 4.74A 4.65A
Maximum power at STC(Pmax) 180Wp 175Wp 170Wp 765Wp 160Wp
Operating temperature -40'C to+85`C -40'C to+85'C -40'C to+85'C -40'C to+85'C -40`C to a85`C
Maximum system voltage 600V DC 600V DC 600V DC 600V DC 600V DC 0 s m n A :5 .o ss .0 m E
0
STC:Irradiance 1000W/m.Module temperature 25'C.AM-1.5 Vollage(V) Z
ov Module temperature(C)
ntec
It r.c—on
n. ,
m
2
MICROINVERTER TECHNICAL DATA
ENPHASE MICROINVERTER M 1 9 0 60 and 72 Cell Modules
Input Data.(QC) 'i M19o-72zoe sr1/vs -M190 72 24Psn/213 `
Recommended input power(STC) 230W 230W
Maximum input DC voltage 54V 54V
Peak power tracking voltage 22V-40V 22V-40V
Min./Max. start voltage 28V/54V 28W54V
Max. DC short circuit current 12A 12A
Max. input current 10A 10A
Output`Datai(AC)'
Maximum output power 190W 190W
Nominal output current 920mA 800mA
Nominal voltage/range 208V/183V-229V 240V/211 V-264V
:\ Extended voltage/range 208V/179V-232V 240V/206V-269V
Nominal frequency/range 60.0/59.3-60.5 60.0/59.3-60.5
a Extended frequency/range 60.0/59.2-60.6 60.0/59.2-60.6
v W t Power factor >0.95 >0.95
Maximum units per branch 21 15 v
Efficiency
Peak inverter efficiency 95.5% 95.5% 1-2
The Enphase Energy Microinverter System improves energy harvest, CEC weighted efficiency 95.0% 95.0% S�
increases reliability, and dramatically simplifies design, installation and Nominal MPP tracking 99.6% 99.6% n
management of solar power systems. The Enphase System includes the
Mechanical Data
microinverter, the Envoy Communications Gateway, and the web-based
Enlighten monitoring and analysis website. Operating temperature range -40°C to +650C -40°C to +650C
Night time power consumption 30mW 30mW = �?
Dimensions (WXHxD) 8" x 5.25" x 1.25"
- Maximum energy production Weight 4.4 lbs P2ECE _VEIL
PRODUCTIVE - Resilient to dust, debris and shading Cooling Natural Convection –No Fans _
J J
- Performance monitoring per module Enclosure environmental rating Outdoor– NEMA b
BY:
- MTBFof 331 years ,Features
Jl
R E L I A B L E - System availability greater than 99.8% Communication Powerline
- No single point of system failure Warranty 15 Years
Compliance UL1741/IEEE1547
SMART
Quick & simple design, installation and management FCC Part 15 Class B
- 24/7 monitoring and analysis Enphase Energy, Inc. 142-00005 REV 04
201 1st Street, Suite 300, Petaluma, CA 94952
C us 8777974743 enphaseene,gy.com ® Primed on 100 percent recycled paper.