09120040 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10025 CRESCENT RD CONTRACTOR:REGRID POWER PERMIT NO:09120040 OWNER'S NAME: PETER MICHALEK 1624 DELL AVE DATE ISSUED: 12/162009 OWNER'S PHONE: 4084216417 CAMPBELL,CA 95008 PHONE NO:(408)927-0811 -I I LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: BLDG r ELECT r PLUMB License Class g L/'j !cf( Lie.H S i^` -en MECH r RESIDENTIAL COMMERCIAL Contractor 5df,o 7/ en (.2A(0/0�( I hereby affirm that 1 licensed under the provisions of Chapter 9 JOB DESCRIPTION: INSTAL ROOF-MOUNTED PV(SOLAR)ON RESIDENTIAL (commencing with Section 7000)of Division 3 of the Business&Professions ROOF Code and that my license is in full force and effect. USING I INVERTER,NO BATTERIES,2.9 KILOWATTS I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this Sq.Ft Floor Area: Valuation:520879 permit is issued. APPLICANT CERTIFICATION APN Number:32616025.00 Occupancy Type: I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save PERMIT EXPIRES IF WORK IS NOT STARTED indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the WITHIN 180 DAYS OF PERMIT ISSUANCE OR grunting of this permit. Additionally,the applicant understands and will comply 180 DAYS FROM LAST CALLED INSPECTION. with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. 'y/, Issued by.t� Date(�AZ- Signature %��J .i7r— Date !t110./.;5 0 OWNER-BUILDER DECLARATION RE-ROOFS: I hereby affirm that I am exempt from the Contractor's License Law far one of All roofs shall be inspected prior to any roofing material being installed. If a roof is the following two reasons: installed without first obtaining an inspection,I agree to remove all new materials for 1,as owner of the property,or my employees with wages as their sole compensation, inspection. will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) Signature of Applicant: _ Date: I,as owner of the property,am exclusively contracting with licensed contractors to construct the project(Sec.7044,Business&Professions Code). ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I hereby affirm under penalty of perjury one of the following three declarations: HAZARDOUS MATERIALS DISCLOSURE I have and will maintain a Certificate of Consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the I have read the hazardous materials requirements under Chapter 6.95 of the performance of the work for which this permit is issued. California Health&Safety Code,Sections 25505,25533,and 25534. I will maintain I have and will maintain Worker's Compensation Insurance,as provided for by compliance with the Cupertino Municipal Code,Chapter 9.12 and the Health& Section 3700 of the Labor Code,for the performance of the work for which this Safety Code,Section 25532(a)should I store or handle hazardous material. Additionally,should I use equipment or devices which emit hazardous air permit is issued. contaminants as defined by the Bay Area Air Quality Management District I will I certify that in the performance of the work for which this permit is issued,I shall maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the not employ any person in any manner so as to become subject to the Worker's Health&Safety Code,Sections 25505,25533,and 25534. Compensation laws of California. If,after making this certificate of exemption,l become subject to the Worker's Compensation provisions of the Labor Code,I must Owneyr or,out ed agent: forthwith comply with such provisions or this permit shall be deemed revoked. 7`u"�". Date:/2/74:742 y APPLICANT CERTIFICATION CONSTRUCTION LENDING AGENCY I certify that I have read this application and state that the above information is 1 hereby affirm that there is a construction lending agency for the performance of work's correct. I agree to comply with all city and county ordinances and state laws relating for which this permit is issued(Sec.3097,Civ C.) to building construction,and hereby authorize representatives of this city to enter Lender's Name upon the above mentioned property for inspection purposes.(We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, Lender's Address costs,and expenses which may accrue against said City in consequence of the granting of this permit.Additionally,the applicant understands and will comply ARCHITECT'S DECLARATION with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. I understand my plans shall be used as public records. Signature Date _ Licensed Professional Community Development ' 10300 Torre Avenue Cupertino CA 95014 Telephone(408) 777-3228 CITY OF Fax(408)777-3333 CUPERTINO Building Department JOB ADDRESS: PERMIT # /DO 2S- CreSCCPT 6p( • on 1 a O o c-E OWNER'S NAME: A7ER /21/Cl//Ice PHONE # yoE- 770-ye, c'D GENERAL CONTRACTOR t&¢ar rie{ pa 141e/)/(IPal (?a 0&c FAX # yo E-- 90`/- S V 7 7 � S9cfliz I am not using any subcontractors: .t1A /7- /7/0 9 Signature Date Please check applicable subcontractors and complete the following information: Ea SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring: Carpeting Linoleum / Wood Glass / Glazing Heating Insulation Landscaping Lathing Masonry Ornamental Sheet Metal Painting/ Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile %1a /.2/7/I 9 Owner/Contractor Signature Date CITY OF CUPERTINO 2 ITEMS OF 2 PERMIT RECEIPT OPERATOR: patg COPY # : 1 Sec: Twp: Rng: Sub: Blk: Lot : APN • 32616025 .00 DATE ISSUED • 12/07/2009 RECEIPT # • BS000009347 REFERENCE ID # . . . : 09120040 SITE. ADDRESS - • 10025 CRESCENT RD SUBDIVISION CITY • CUPERTINO IMPACT AREA OWNER • PETER MICHALEK ADDRESS • 10025 CRESCENT RD CITY/STATE/ZIP . . . : CUPERTINO CA, CA 95014-1050 RECEIVEDFROM . : REAL GOODS ENERGY T CONTRACTOR • TOM MCCALMONT LIC # 24276 COMPANY • REGRID POWER ADDRESS • 1624 DELL AVE CITY/STATE/ZIP . . : CAMPBELL, CA 95008 TELEPHONE : (408) 927-0811 FEE ID UNIT QUANTITY:. AMOUNT PD-TO-DT THIS REC NEW HAL 1BCBSC VALUATION 20, 879 . 00 1 .00 0 .00 1 . 00 0. 00 1SOLARRES FLAT' RATE 1 . 00 207 . 00 0.00 207. 00 0. 00 TOTAL PERMIT : 208 .00 0 . 00 208 . 00 0 . 00 METHOD OF PAYMENT AMOUNT REFERENCE NUMBER CHECK 208 . 00 #1133 TOTAL RECEIPT : 208 . 00 VOICE ID DESCRIPTION VOICE ID DESCRIPTION 301 ROUGH PLUMBING 303 ROUGH MECHANICAL 304 ROUGHELECTRICAL313 ROOF NAIL 505 FINAL ELECTRICAL- - 507 FINAL PLUMBING 508 FINAL MECHANICAL - \� /// CITY OF CUPERTINO SOLAR PANEL PERMIT APPLICATION FORM CUPERTINO APN# Date: 3a (v - Das • of /2/o?/09 Building Address: /00025 CRESCENT xx. Owner's Name: Phone#: • ?E7CP VYlme,t/ALEK "JD&- tfa7- 6Y/ 7 Contractor: Phone#:409- 370- 3600 Contractor License#: RE<,Rib Aiwa?, INC-. Fax #: YoJ 90Y- cc/77 826.5 730 Contact: Phone#:9oS- L//0- 29/n y Cupertino Business License#: A(i9RA NAU4E71/ Fax#: 5Y77 Job Description: /nci.a. f r0o2 -Vnn'n fro/ 7V (S0/ar) QN /Loc/o1a-+-i'tra( raziotiSinta / /NvLRTE( • No bantMiPS / ,7.9 irt) Residential ,k1 Commercial ❑ Number of Panels/Units: Kilowatts: .2, 9 Valuation(cost of project): a C/ g ri 9 Project Size: Express] Standard ❑, Large Li Major❑ Green Points: / 1.2 KW -6 Points 0 2.4 KW- 12 Points 19 3.6 KW - 18 Points 0 Quantity Fee ID •Fee Description Fee Permit Type Group 1 SOLARPANL Commercial Solar Panel E SOLAR-COMM IPHOTOVCOM Photovoltaic System E Commercial/Multi-family I BSEISMICO Seismic Commercial E 1 ELCPLNCK Plan Check Fee E • j 1BCBSC Cal Bldg Standards B ALL PERMIT TYPES Commission Fee COMM & RESID 1 SOLARRES Residential Solar Panel E SOLAR-RES Revised 08/20/2009 Permit ;Npplication Peter. ichalek 10025 C, tVl Rd. Cupertino, Ca 95014 Suitable Mounting Location of Solar Array SUBM�TTA _ • Ise: • 20 total PV panels to be mounted on UniRac SolarMount aluminum roof racks. Racks are to be grounded. (See attached Unirac data sheets) • Standoffs for racks to be lag-screwed to rafters with 5/16" x 3 1/2" stainless steel lag screws every 4' - 6' typically and sealed with long-life polyurethane,and flashed. • Panels to be flush mounted on south facing roof. • Mounted height of panels above roof to be less than 7". • Roof loading to be less than 3.5 lbs. per sq. ft. and less than 35 lbs. per support point1cQ • All electrical work will be performed by a licensed contractor and in c ff rmance wrth,the 2005 Y NEC. SHEET PAGE G� gY. Title Page 1 . Site Plan 2 rn Grid Tie Plan 3 Attachment Detail 4 • System Specs 5 Wire Calculations 6-7 Module Cut Sheet 8 Inverter Cut Sheet 9 UniRac SolarMount Cut Sheet 10-12 QuickMount Cut Sheet 13 Permit Application -1 - REGRID POWER, INC. 10025 Crescent Rd. Cupertino,Ca 95014 , Permit Application Information , for Photovoltaic Solar Electric System \���) i ��� REGRID,+POWER Property Owner �� - Name Peter Michalek Installation Address 10025 Cresent Road Cupertino, CA 95014 Phone (408) 421-6417 _Jwv4.orc i1 J • Seller ,°;.-1-u�1 Company Regrid Power,-1624 Dell Ave., Campbell, CA, 95008 E-- Contractor's License No. #865730 V} t3 k:. ContractorsBond No. . 1040934 Surety Company of the Pacific eff. 1/1/2009 ,., • Workers Compensation . C20070391601 Majestic Insurance Company eff. 6/1/2009:) Contact/Applicant Kara Haugen, Operations Specialist C j Phone Numbers 888-273-4743 or 408-410-2964 (mobile) .--f i4) Project Description 2,899W Grid-Tied Solar.Electric Systemaincluding the following components: „.. c,0.1 i!"' Photovoltaic Modules (Panels) 20 Sharp NT-175UC1 PV Panels .ft r C 9 Inverter 1 SMA Sunny Boy SB3000US (240V) Inverter CLc AC Disconnect Switch 0 -- DC Disconnect Switch 1 Inverter Integrated DC Disconnect(s) Mounting Racks Roof UniRac SolarMount racking components$Y''' PV Panel Specifications System Specifications Solar Panel Type `NT-175UC1 . Total Number of Solar Panels 20 Load Current(Imp) • 4.95A Load Current Produced by Array 9.90A Short Circuit Current (Isc) - 5.40A Short Circuit Current Produced by Array 10.80A Load Voltage (Vmp) 35.4V Load Voltage Produced by Array 354.0V Open Circuit Voltage(Voc) . . 44.4V Open Circuit Voltage Produced by Array 444.0V Watts per Panel (at STC) 175:0W STC Watts Produced by Array 3,500W Watts per Panel (at PTC) 151.8W PTC Watts Produced by Array& Inverter 2,899W Panel Width 32.5" Array Width 28.1' Panel Length 62.0" Array Depth 10.4' • Individual Panel Weight 37.5 lbs. Array Weight (including racks) 883.3 lbs. Panel Dead Load Concentration 2.6 lbs./sq.ft. Panels & Mounts Load Concentration 3.0 lbs./sq. ft. Dead Load per Support Point 31.5 lbs. PV Array Wiring& Overcurrent.Calculations(DC) Source Circuits to Inverter Wiring 6 Overcurrent(DC) USE-2/RHW-2 Cable in free air #10 AWG USE-2/RHW-2 Cable in conduit #10 AWG Working Voltage 354.0VDC Working Voltage 354.0VDC Temp. Derated Ampacity of Cable 18.15A Temp.Derated Ampacity of Cable 18.56A NEC Required Cable Ampacity • 8.44A NEC Required Cable Ampacity 8.44A PV circuit fuse not required Source circuit fuse not required Equipment-Grounding Conductor,. #10 AWG Equipment-Grounding Conductor #10 AWG Inverter to Grid-tie Wiring 6-Overcurrent(AC). Max. System Voltage Calculations(DC) THHN/THWN-2 Cable in conduit #10 AWG Lowest Ambient Temperature for Site -5°C Working Voltage 240VAC . Max.Voltage Produced by Array(Voc) 444.0V Temp. Derated Ampacity of Cable 37.60A , Manufacture's Temperature Coefficient -0.36%/°C NEC Required Cable Ampacity 15.63A Max.System Voltage at Low Temp 492.0V Overcurrent Protection(AC breakers) 20A Equipment-Grounding Conductor #10 AWG AC Grounding Electrode Conductor #6 AWG DC Grounding Electrode Conductor #6 AWG S Solar PV Wiring Calculations- For Plan Check Only Prepared by: Charlie Dearie 10025 Cresent Rd. Cupertino 95014 12/3/2009 1. Array PV panel NT-175UC1 open-circuit voltage 44.4 V voltage temperature coefficient' -159.8 mV/°C load voltage 35.4 V load current 4.95 A short-circuit current 5.40 A panels in series (string length) 10 number of strings 2 short-circuit current(per string) 5.40 A peak operation factor x 1.25 690.8(A)(1) continuous current rating 6.75 A safety factor x 1.25 690.8(B)(1) max. string current• I 8.44•AI max. ambient temperature(sun) 70°C max. ambient temperature (shade) 40°C ASHRAE 20-Yr Extreme • min. ambient temperature (record low) -5°C ASHRAE 20-Yr Extreme voltage temperature coefficient -159.8 mV/°C 2008 NEC 690.7(A) temperature difference below STC(25°C) -30°C cold-weather voltage adjustment 4.8 V open circuit voltage (per panel) 44.4 V max. open circuit voltage(per panel) 49.2 V panels per string x 10 max. open circuit voltage(per string) ' - 492.0 V open circuit voltage (per panel) . 44.4 V voltage correction factor x 1.13 690.7(A) max. open circuit voltage (per panel) 50.2 V panels per string x 10 max. open circuit voltage (per string) 501.7 V 2. Inverter Inverter SB3000US (240) nom. AC voltage 240 V max. AC output current 12.5 A max. output current 12.5 A safety factor x 1.25 690.8(B)(1) inverter circuit max. current 15.6 Al solar breaker 20 A All calculation assume 75°C terminals Unless otherwise noted, references are to the 2005 NEC and the 2007 CEC Page 1 of 3 Solar PV Wiring Calculations- For Plan Check Only Prepared by: Charlie Deane 10025 Cresent Rd. Cupertino 95014 12/3/2009 4. Inverter to subpanel (conduit) wire size 10 AWG one-way max. length 30 ft ampacity(90°C column) 40.00 A Table 310.16 temperature derating factor(shade) x 0.91 Table 310.16 bundle adjustment factor x 1.00 Table 310.15(B)(2)(a) derated ampacity 36.40 A ampacity(75°C column) 35.00 A Table 310.16 allowed ampacity 35.00"A' resistance per unit length 1.24 0/kft Chapter 9, Table 8 temperature correction (shade) 0.887 Ch. 9, Table 8, Note 2 one-way length 30 ft effective number of conductors 2 total resistance 0.07 4 • load current 12.5 A conductor voltage drop 0.82 V load voltage (nominal) 240 V voltage loss at load ' . 0.34% • area of 10 AWG-THWN-2 0.021 sq in Encore Wire number of conductors x 3 subtotal area of AC conductors 0.063 sq in area of 6 AWG THWN-2 0.051 sq in Encore Wire total area of AC conductors 0.114 sq in area of 0.75" EMT conduit 0.533 sq iri Chapter 9, Table 4 conduit fill ratio .21.4% main panel OCPD 125 A solar backfeed OCPD 20 A total source OCPD at main panel 145 A • main panel bus rating 125 A main panel bus utilization 116% 690.64(B)(2) exc. • All calculation assume 75°C terminals Unless otherwise noted, references are to the 2005 NEC and the 2007 CEC • Page 3 of 3 7 R7 solar electricity t: , ..000. 175 WATT Multi-purpose module ideal for ground mounted solar systems and the preferred solution for landowners. MULTI-PURPOSE MODULE NEC 2008 Compliant ENGINEERING EXCELLENCE High module efficiency for an outstanding balance I I111 11 I I of size and weight to power and performance. DURABLE I— I-411—•.—I • —.• —. Tempered glass.EVA lamination and 1^ I weatherproof backskin provide long-life and • f 1T +.—4._ •_ enhanced cell performance. ���o�y� Ti- ♦_ RELIABLE I) I I 25-year limited warranty on power ouutpu`t.. I � t —I HIGH PERFORMANCE This module uses an advanced surface texturing process to increase light absorption and Improve efficiency. I r ,= —{III. (''., I — a �OA�' I pEe-; � III- I _ I j � I, jai I .71 T r1 NT-175UC1 i N` j . MULTI-PURPOSE 175 WATT -- A`' LIT MODULE FROM THE WORLD'S • - .'a,�ca •_ TRUSTED SOURCE FOR SOLAR. - ,,,;•-•:-.2,1.-.e......-<$:--.--.-- z \ i ,. ___ ` •�c� t 0. I \ Using breakthrough technology, made possible Sharpmultl-putpose modules offer Improved Frame Technology industry-leading cerfor performance forb nearly50 years of proprietary research a dunetyf applications. and development, Sharp's NT-175UC1 solar module incorporates an advanced surface SHARP:THE NAME TO TRUST texturing process to increase light absorption when you choose Sharp,you get more than well-engineered products.You also get Sharp's . and improve efficiency. Common applications proven reliability,outstanding customer service and include commercial and residential grid-tied the assurance of our 25-year limited warranty on roof systems as well as ground mounted arrays. power output.A global leader in solar electricity. Designed to withstand rigorous operating sharp powers more homes and businesses than conditions, this module offers high power any other solar manufacturer worldwide. output per square foot of solar array. BECOME POWERFUL Sue 175 WATT ``� ./1/.........,.......- NT-175UC1 ••-• r. NEC 2008 Compliant >�^-r'>'w^'" Module output cables now 12 AWG with locking connectors ELECTRICAL CHARACTERISTICS IV CURVES Maximum Power(Pmax)' 175 W cal Temperate,..sr Tolerance of Pmax +10%/-5% i no I.Type of Cell Monocrystalline silicon a I-4 Cell Configuration 72 in series ' n,O1ea„ s Open Circuit Voltage(Voc) 44,4 V aa� Maximum Power Voltage(Vpm) 35.4 V 4111\\ Short Circuit Current(Isc) 5.40 A F. On a Maximum Power Current(Ipm) 4.95 A / Module Efficiency(%) 13.45% r •Maximum System(DC)Voltage ' 600 V ., , Series Fuse Rating 10 A e i I NOCT 47.5°C Temperature Coefficient(Pmax) .0.485%/°C a to n w •. >o Temperature Coefficient(Voc) ' -0.36%/°C wine mi .0•v Temperature Coefficient(Isc) 0.053%/°C r°"`"`rbwihr,`"^'yee^""""•'"' — '°-^^ "Measured at(STC)Standard Test Conditions.25°C.I leW/m'insolation.AM I.5 MECHANICAL CHARACTERISTICS DIMENSIONS Dimensions(Axe x C below) 32.5d a 62.0'xl8"/826 a 1575 x 46mm BACK VIEW -Cable Length(G) 43.3"/1100mm h- A -1 SIDE VIEW Output Interconnect Cable" 12 AWG with MC4 Locking Connector T ® e Weight 35.3 Ibs/16.0 kg • D .0 TI I O i Max Load 50 psf(2400 Pascals) 1 "A safety lock clip(Multi Contact part number PV-SS H4)may be required in 0 readily accessible locations per NEC 2008 690.33(C) ---?I _ .QUALIFICATIONS -(-)� e(•) UL Listed UL 1703 Fire Rating Class C cOus WARRANTY —1 rl4IWA5'N nen 25-year limited warranty on power output I Contact Sharp for complete warranty information E Q m rea 8� J_ }1 F H --I I--0 A B C D E 32.57026 mm 62071575 mm 18746 mm 13.47340 mm 3.97100 mm Design:ma lbeciticeton:am sub,rct:c.Cna-ge a4-au;attire Sharp is a registered trademark of Snags Corporation.All otner trademarks are property F G of their respective owners.Contact share to ootain me latest product manuals before using 3117190 mm 43371100mm any 5-mu-.eviCe Cavi•onelo Sola,ins:,t'Lem-m:Pacific oozy Pl a-agrrmnr nummn Cr: Contact Sna,u FOP tolerance spocaica;inns 0.H® S /� SHARP ELECTRONICS CORPORATION /'�'_L"q� 5901 Bolsa Avenue,Huntington Beach,CA 92647 1-800-SOLAR-06•Email:sharpsolar@sharpusa.com www.sh a rpu sa.com/sola r e 2008 Sharp Electronics Corporation.All nghts reserved. 03L-033.PC-II-03 5.1 • SUNNY BOY 3000US / 4000US F I . ,•i s Ff. 4 Aal 1A �� f r • !.I t A A• 1 "� �{ r n rrl9i .4. I h, Y t + sar414 • S1 ,,[ . . 1.7 st rIp 44 V•ttCyr„t,r {rc 1 1 , ?. r • fi1T it d1.t7�y� ±y•� 6 1..? msTe ?. 'Highest CEC efficiency in its class •Sealed electronics enclosure 8 • Ideal(or residential or gist •' • \•Integrated load-break rated OpIicooITM commercial applications - lockable DC disconnect Twitch •Comprehensive SMA • Rugged cast aluminum outdoor • Integrated fused series string , communications and data I • rated enclosure US combiner - ,collection'options'' - • UL 1741/IEEE-1547 compliant C • 10 year standard warranty SUNNY BOY 3000US/4000US The best in their class Our US series inverters utilize our proven technology and are designed specifically to meet IEEE-1547 requirements. Compact design makes them ideal forresidential use and the integrated lockable DC disconnect makes installation more cost effective.They are field-configurable for positive ground systems making them more versatile than ever.Increased efficiency means better performance and shorter payback periods.Throughout the world,Sunny Boy is the benchmark for PV inverter performance and reliability. 9 Technical Data SB3000US SB4000US Recommended Maximum PV Power(Module STC) 3750 W 4375 W @ 208 V/5000 W @ 240 V DC Maximum Voltage 500 V 600 V Peak Power Tracking Voltage 175-400 V 0208 V 220-480 V @208 V j 200-400 V @ 240 V 250-480 V @ 240 V DC Maximum Input Current 17 A 18 A' DC Voltage Ripple <5% <5% - Number of Fused String Inputs 2(inverter),4 x 20 A(DC disconnect) 2(inverter),4 x 20 A(DC disconnect) ` PV Sort Voltage 228 V 285 V AC Nominal Power 3000W 3500W@208 V/4000W 0240V AC Maximum Output Power 3000W 3500W@ 208 V/4000W•240V AC Maximum Output Current 15A0208V, 13 A•240V 17 A AC Nominal Voltage Range 183-229 V @ 208 V 183-229 V@ 208 V - 211 -264 V 0 240 V 211 -264 V 0 240 V AC Frequency nominal/range 60 Hz /59.3-60.5 Hz 60 Hz/59.3-60.5 Hz Power Factor(Nominal) 0.99 0.99 Peak Inverter Efficiency 96.5% 96.8% • CEC Weighted Efficiency 95.0%0 208 V 95.5%@ 208 V 95.5%•240 V 96.0%0 240 V Dimensions:W x H x Din inches 17.8 x 13.8 x 9.3 17.8 x 13,8 x 9.3 Weight/Shipping Weight 84 lbs /97 lbs 84 lbs /97 lbs Ambient Temperature Range -(3 so 113°F -13 to 113°F - PowerConsumption:standby/nighttime <7W/0,I W <7W/01W Topology Low frequency transformer,true sinewave Low frequency transformer,true sinewave Cooling Concept OptiCaoltm,forced active cooling OptiCooN",forced active cooling Mounting Location:indoor/outdoor(NEMA 3R) •/• •/• LCD Display • • Communication RS485/wireless 0/0 0/0 -- Warranty:10-year • • - Compliance:IEEE-929,IEEE-1547,UL 1741,UL 1998,FCC Port 15 A 8 B • • Specifications for nominal conditions •Included 0 Optional 'Also available in 16 A current limited configuration for use in 100 A service applications. NOTE:US inverters ship with gray lids. Efficiency Curves , -"r1"'" s—� fii 61 . cc 1,14•;1,#,,j:yr.... _ . --. . 111 tow job • T,1 R t`.t�, I.Iw1 - Tel. +1 916 625 0870 Toll Free +1 888 4 SMA USA www.SMA-America.com SMA America, LLC THE STANDARD IN PV MOUNTING STRUCTURES'" �sy==r- -1` PV's Most Versatile Mounting System Ge"Y.v ti .. �Sa a pt Flush Mount 1l V i • ?.hist,,.: I Low Profile .-- 00. _ lir \ S's A r _ • ' -.r 1 High Profile - - `' {r > www.unirac.com SolarMount is much more than a product. It's a system of engineered components that can be assembled into a wide variety of PV mounting structures.With SolarMount you'll be able to solve virtually any PV module mounting challenge. It's also a system of technical support: complete installation and code compliance documentation, an on-line SolarMount Estimator, person-to-person customer service, and design assistance to help you solve the toughest challenges. Which is why SolarMount is PV's most widely used mounting system. U.S.Des.patent Nos.D496,2485,0496,2495 Other patents pending. /° � tri ,3 ` l r Three great innovations make PV's most ' versatile mounting system better than ever j \l�+ EV / l 4� A.V. M •,r: t . t\ iL . rti11l:i0I Lill I. 1,1•.:111 Su1ur\I.41111 I, 1.,,111.1 1 1 1111,• )1.' A rt cr, ' t _ . r,, LP) ,r I;nil;_,r Gruuu,lin}: Clip \/ /Jt ;�` UniRac Grounding Clip SolarMount® Light - Save time and materials by eliminating the Lower-cost SolarMount Light rail employs 38 need to tediously install a grounding lug on percent less aluminum than standard rail, each module and bare copper wire between yet it's more than strong enough for flush all modules.Instead,simply press one of applications.Use the same installer-friendly these clips into the top slot of the SolarMount top mounting clamps and footing components rail at the end of the row and between each that work with SolarMount standard rail. pair of modules as they are installed.Align and fasten the modules with SolarMount top mounting clamps in the usual manner.The SolarMount®Ballast Frame nibs of the UniRac Grounding Clip pierce the anodizing as the mounting nuts are tightened, The SolarMount system is more flexible than thus creating a ground path through the ever with the introduction of a ballast frame, SolarMount rail.Complete the installation by in most cases requiring no penetrations installing one grounding lug at the end of the whatsoever.Learn more from our data sheet SolarMount rail. Connect the lugs with a bare SolarMount Modular PV Ballast Frame, copper wire to ground the entire array. which you can download at www.unirac.com. _ s Vrfre ‘. F 4 y SOLARMOUNT® �45 > is>< .S lirce-:.._.: ----__:::,..i,..:__ -91 -!I ` I ' •,,?,.. PV's most versatile mounting system O X15 = t .. SolarMount® Rail Options Srt.l:,..i;; :v! :-iJ FID(heavy dutv)t ail adds [�d,i_o . I I...., -�_... _a —_ .. the Solatbluunt advantage copy poleTopsi,,U I.As(sec .) .Y I a —'-A' I -4 separate data sheets),;I;Indn -'—'--"- � r I s tet+ custmn applications that f t . 1_ I • �t..: require long spans. u a !' • • Si, 1 rl yl:i _ i u,.f ° >, ' � _ de titite Standard rail gives you I, . 4 ultimate flexibility,including "'e �,, `?s f t , i I c�r i ,i . bottom mounting and tilt-up �i� , 7- [ I b ::, ' I , .K. 1 i',:.1. ..ii,-; `� -t..:-..1-.1.e'.1 Sol Ill;; • !i, : '�`•.„ )�`.[�l:• e ® + � • In(lush mounted allays,easy ) ' t handling SolarNloun[I� �. ‘t'4-4.- t: ) Light rail saves aluminum � p and cspcnsc without II�;'T.. �yl '. compromising structural t integrity. • • Top mounting and grounding slots —.\ • Splice Bars it In flush and low profile installations,securely join SolarMount®rail sections using rail �( footing slots. Bottom mounting slots ► J . rii ... ,... ..... ...... Splice bar ti Footingand splicing slots ► /�� D g // t t t" ' : Module,/Vlounting `(:;•` r� rr a�, / I 1 . ; .a nl��la" S. ync ni -,I, li ni (.-I'un/ca / ." 3` �-� . - 1•. c 1 •-.. .:::•...415 rr ya-ao) j rrPF i= ae • , y , 2---,..., oi �C .,c, r ®�Q . t/ Crt = 0. Top mounting Auadh nodules one-by-one to in:tolled milt I , _ - • - L' i --- — 1l( 1 . 1. • Bottom mounting:Preassemble full rows before final installation(standard and HD rail only). • Top Mounting Clamps Bottom Mounting Clips Junction Plates - SolarMount r _ Use bottom — - -- - In shared-rail -- T-bolts quickly �\ mounting clips �° r / configurations mount your I®et JL\ � � (standard and - l- (standard and _ Il ��L_ modules to any ', ' ' HD rail only) rq e -' HD rail only), ,) SolarMount rail ` `� whenever you . >%µ'• attach modules }:Ti- -from the top. s,,,. -\ prefer to attach �, .. with four-sloth " • This is ideal for 1M% H rails directly u; junction plates. I 9 flush mount to the module -r , North•south r , : applications, mounting «_ _ ..' slots secure r - _ �> such as holes.Simply -- t. the rail to residential rooftops,where it r fit the clip into its rail slot over the plates.East-west slots secure a is most convenient to secure -. the mounting bolt for a secure module on each side of the rail. footings and rails before = connection.Adjust the clip installing modules.Clamps j position anywhere along the rail securely grip any point of _i slot.Alignment of rails to module the module frame,freeing A, mounting holes is always easy and you from the constraints of /� convenient. module mounting holes. T-bolt System Footing Ic�jhlr cninhhtncn: . spc: l In .Iallalirn Secure footings bolt quickly and easily to footing bolt slots in any SolarMountw rail. s!aodhiIl., Use standoffs whenever flashed installations Standard for ground mount are required,on tile roofs.for example. installations, L-feet mount I Two-piece aluminum standoff allow precise rails to residential and �' ' placement of a flashing over a secured base commercial rooftops as prior to the installation of the standoff itself. tvell.Use them alone above All standoff types come in four standard asphalt composition shingles - or in conjunction with flat top 1-4"(t heights:3.4,6.and 7 inches-Appropriate - (lashings ate available. standoffs. Rad mounting holes ore at two heights, In flush mounts, use the upper hole p to raise the modules and promote air flow 1 for cooling.Where aesthetics are the greater 0 concern,use the lower hole to keep the • modules close to the roof. • Two-piece aluminum Steel raised Steel Qat top flattop flange Strut-in-Tube Style Legs , , Quickly set the precise tilt angle required. Styles are available for high profile(1 or 2 , '•� �,; , legs per rail)and low profile installations. � �... '•� Each series offers three leg lengths so \ • ' towrole that you can adjust to exactly the tilt P f angle you want—up to a maximum ‘,11/ of 60 degrees—without cutting and drilling at the job site. • 44� Strut-in-tube leg 1 I� \ ` High profile 1 v Start at www.unirac.com Download our SolarMount®Master Price List with Sizing Charts and installation manuals.Generate quick price estimates with our on-line SolarMount®Estimator. I till „ighaml'ilin i_ T "A - Mount any framed .. - - PV module' st., t: Y ti SimItch � ®eppr ®mo ; \i 7 /j Um-;Na. • I. ye-.e. 56-0)12...-a''rr`°lM�; off: `Lf,i Code Compliant Warranty The SolarMount®system is PE certified.Call UniRac SolarMount®is covered by a 10-year limited product for documentation applicable to your building code. warranty and a 5-year limited finish warranty.For complete warranties,download any SolarMount® Component Specifications installation manual from our web site. 6061-T6 and 6063-T5 • SolarMount ballast frame 6105-75 aluminum extrusion • SolarMount®rails • Mounting clips and clamps • Tilt legs and L-feet • two-piece standoffs Severe Condition 4(very severe)zinc-plated welded steel • One-piece standoffs 18-8 stainless steel • Fasteners (ii ,-223), THE STANDARD IN PV MOUNTING STRUCTURES" Pub 060901-1ds • October2006 1411 Broadway NE, Albuquerque NM 87102-1545 USA ©2006 UniRac,Inc.All rights reserved. • uit' 'iki oun I' • Your SOiun .in Mounting Products . Solar • 1120 + Conduit • HVAC • Custom composition-Mount Specifications Quick Mount PV® is an allin-one',waterproof flashing and mount to anchor photovoltaic racking systems, solar thermal panels, air conditioning units, satellite dishes,-or anything you may need to secure to a new or existing roof. It is made in the USA of all aluminum and includes stainless steel hardware. It works with all standard racks,installs seamlessly and saves labor by not need- ing to cut away any roofing, will out live galvanized.2 to 1, and is a better low-profile mount. CID Flat Washer 1° x 5/16" EPDM Rubber Washer.60,Durometer. \ (2) Sealing Washer 3/4" x 5/16"' Hex Nuts • 5/16"Bolt 5/16" x 6" • -5/16" 1-1/2" Machine, 1-1/2" Spacer,3"1.2g Mount& Flashing Aluminum Mount 2-1/4"I x 1-1/4"w x 1-1/4"h Flashing .05"thick • For standard composition•roofs:,flashing is 12" x 12", mount is attached 3°off center 32-.1:.'!"-:2, , .,P.rypr '. Lao pull-out (withdrawal)'capacities (lbs).in typical lumber Lag Bolt Specifications • Specific 5/16"shaft 5/16"shaft gravity per 3" per 1" thread depth thread depth Douglas Fir,Larch .50 798 266 Douglas Fir,South .46 705 235 Engelmann Spruce.Lodgepole Pine (MSR 1650 f&higher) .46 705 235 Hem,Fir .43 636 212 Hem,Fir.(North) .46 705 235 Southern Pine .55 921 307 Spruce,Pine,Fir .42 615 205 Spruce.Pine,Fir(E of 2 million psi and higher grades of MSR and MEL) i ..50 798 266 Sources:Uniform Building Code;American Wood Council Notes:1)Thread must be embedded in a rafter or other structural roof member. 2)Pull-out values incorporate a 1.6 safety factor.recommended by the American Wood Council. 3)See BC for required edge distances. 936 Detroit Ave Suite D,Concord, CA. 94518 Phone: (925)687-6686 Fax: (925)687-6689 Email:.info©aquickmountpv.com www.quickmountpv.com I of 4 • . 13 ' COMMENTS/NOTES: • , COMPOSITION SHINGLE ROOF SINGLE LAYER • 22° PITCH SERVICE ENTRANCE -, AND LOAD CENTER INVERTER \\N: ill • 0 O CD 0 O O Z 3.0' - 60.2'I ...4 1 U L - `^ RE /NOTESDATENIT goun�QnQ�O, .w ING ITLE � l��i�M��aM7 g T �PV ROOLAN i p WI �, / O il1 E UNIRAC RAIL / °.' .'o ' ° e '• .�OSaP� u'FrROJECT NAME/ADDRESS 3• :Or O O i "--' Peter Michalek -') �. -"7� i.� j . - 10025CrescentRd. _ 1 a . DECK : Cupertino,Ca 95014 APPROVED IN ACCORDANCE WITH THE CITY OF CUPERTINO CODES AND ORDINANCES . DATE DATE /11.-4‘---° P • - • ,/I1: SIGNED - • REA [ GOODS This set of plans and specifications MUST SOLA R be kept on the job at all times and it Is un taiful to make any changes or alterations . on same without wAtten permission from the Building Department,_,__of C st • 1624 DELL The stampingTplan 20 FLUSH-MOUNTED CAMPBELL,CA 95008 SHALL NOT be nSd to panne a to be an PHONE: L AVE.A 370-3600 approval of the violation of any provisions PHONE: (408) of any City Ordinance or State taw. SOLAR MODULES DRAFTER K. HAUGEN DATE PAGE 0 T12/02/09 1 / • 1"- 10' SIZED FILE NAME SITE PLAN_MICHALEK DWG.NO. APP_ 4868 ONOTES: DC IN AC OUT / INTERNAL . O ? it e DC DISCONNECT l sWRCH WITH o / ISA FUSES • © 0 lO _ o LQ1 L2� N PE PE `• • • b oon , . +Posmve T000. I I I I• h I -NEGATIVE I I CD L Q 0 I 0 9 • A I 8 L2 N Ll A . • „c 0 0 o 0„---- . I • ED 0 0 0 . 0, 20- 0 e �. o - - 1R \��\1�//�/I oEC SIGNAGE ALL SIGNAGE PHENOLIC TYPE UNLESS NOTED ' O I - OFLEXIBLECONDUITLABELS:"CAUTION:SOLAR CIRCUIT” tsz4DET.LavE• 02 SIGNAGE AT INVERTER:"MAX AC OUTPUT GROUND J • - C/4.QBELL C/�9511De - CURRENT 13AAND OPERATING AC VOLTAGE 240V - PNJNE.Fridna37P3SW . Q3 SIGNAGE AT INVERTER"OPERATING CURRENT 9.90A METER 1- .- www.regnd,can 'OPERATING VOLTAGE 354V MAX CURRENT 10.BA . ' . MAX• VOLTAGE 492V IUGR GRID-TIED SOLAR UTILITY . I I • ELECTRIC SYSTEM UNE IN I NEGATIVE GROUND Copyright®2009 by Regid Power.Inc BASIC SYSTEM I 10 All lights reserved.Proprietary information -- _— 1 which may not be reproduced.65doSetl. CUSTOMER NAME IADDRESS. or reciseibuted without permission. Peter Michalek 10025 Crescent Rd. O EQUIPMENT SCHEDULE WIRE SCHEDULE Cupertino,Ca 95014 TAG DESCRIPTION PART NUMBER NOTES TAG DESCRIPTION WIRE NO.OF CONDUIT CONDUIT SALESMAN/INSTAL DESIGN GAUGE CONDUCTORS TYPE SIZE J.Williams 1 Solar May Sharp NT-175UC1 2 strings, 10 modules per string STC=175W,PTC=151.8W 2 I USE-2/RHW-2 #10AWG 4 EMT 3/4" 3 Inverter SMAAmerica SB3000US Integrated DC Disconnect 4 Solid Copper Ground #10 AWG 1 RRAER K Haugen 7 Solar Breaker 20A 5 THWN-2 #10AWG 3 EMT 3/4" UST REVISION A.GE 12/02/09 8 Main Breaker 125A Combined Equipment SCALE Size MA A 9 Main Service Panel Rated 125A 240VAC Labeled as per NEC 690-54 • 6 Ground and grounding #6 AWG 1 / 3 electrode conductor RLE NAME 8690-56 1_Negative Ground Basic System 10 Ground Rod Existing Ufer dUW.NG NUMBER 4869 gV COMMENTS/NOTES —sa-� �11 -1' • SCJ INSTALLATION ORDER UNIRAC SOLAR RAIL I.AOUIEMPIET,MARK HOLE LOCATION AND �J7 ORH0. M O01 5/16'HEX NUT 2 PILOT rv%M SEAL E`MPOLYURETHANE IJ CJ SEALANTSLIDE OM 3IR OM SHINGLESTOAND LAG HANGER BOLT L-OM T NINTO RAFTER • L-FOOT ATTACHED I TIGHTEN Lsooi ONTO OM BLOCK ns) O HANGER BOLT SEATED INTO OM OM FLASHING UNDER •Ira © • — f-72-BeMeen Footings (E)ROOF COVERING O m nEMENr5IMIMMEMMIa It._ I I I I (E)ROOF DECKING Q�� 1 %XX)00(X -/-h %% �4 NO. REV/NOTES DATE INIT (E)RAFTER DRAWING TITLE 16 (E)2%6 RAFTERS 16"OC 6/16"DIA LAG BOLT STANDOFF AND (2-117'EMBED,MIM ROOF PLANE DETAILS A FRONT VIEW OF ROOF PLANE QUICKMOUNT I,VA nOnv PROJECT NAME/ADDRESS V Peter ISL jdWelc_ 131.:-10025 Crescent Rd. Cupertino;Ca 95014 • • `%\ e fol11`` R CA [ GOODS SOLAR 1624 DELL AVE. CAMPBELL, CA 95008 PHONE: (408)370-3600 www.regrid.com DWI ER K. MADDEN LAST RENSIN PAGE 12/02/09 SCALE NOT TO SCALE Nae OT FILE NAME STANDOFF-ROOFPLANES