07020139!0O
, to
[ZM
v<y
.�H
of
�pm,U
rv,r
:0<
qnq(01a
Soo
Y—rn
y
Z3
CITY OF CUPERTINO
BUILDING DIVISION PERMIT
BUILPERMIT
gI))�1J'PhRAKE DR
KELLAR -'ONST .
NO.
07020139
0"INER'S NAME:
PERMIT ISSUE DATE
3ANTANU SINHA
115240 MkDRONE HILL RD.
05/16/2007
PHONE:
SANITARY NO. CONTROL NO.
(408)867-9743
ARCHITECT/ENGINEER:
BUILDING PERMIT INFO
BLDG ELECT PLUMB MECH
LICENSED CONTRACTOR'S DECLARATION
licensed Chapter 9
Job Description
I hereby affirm that I am under provisions of (commencing
with Section 1000) of Division 3 of the Business and Professions Code, and my license is
ADDITION: 480 ' - KITCHEN & DINING
in full force and effect.
License lass Lic.7i
Date Con1u=W
ARCHITECTS DECLARATION
I understand my plans shall he used as public records
Licensed Professional
OWNER -BUILDER DECLARATION
1 hereby affirm that 1 am exempt from the Contractor's License Law for the
following reason. (Section 7031.5. Business and Professions Code: Any city or county
which requires a permit to construct, alter, improve, demolish, or repair any structure
prior to its issuance, also requires the applicant for such permit to file a signed statement
that he is licensed to the of the Contractor's License Law (Chapter 9
3q. Ft. Floor Al ea
Valuation
pursuant provisions
(commencing with Section 7000) of Division 3 of the Business and Professions Code) or
$1 0 2 8 9 7
that he is exempt therefrom and the basis for the alleged exemption. Any violation of
316 3 2 Number
Occupancy Type
Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of
not more than fire hundred dollars ($5,M).
..Aff
❑ 1, as owner of the property, or my employees with wages as their sole compensation,
Required Inspections
will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business
and Professions Code: The Contractor's License Law does not apply to in owner or
property who builds or improves thereon, and who does such work himself or through his
own employees, provided that such improvements are not intended or offered for sale. If,
however, the building or improvement is sold within one year of completion, the owner -
builder will have the burden of proving that he did not build or improve for purpose of
sale.).
❑ I, as owner of the property, am exclusively contracting with licensed contractors to
construct the project (Sec. 7044. Business and Professions Code:) The Contractor's Li -
cerise Law does not apply to an owner of property who builds or improves themon, and,
who contracts for such projects with a contractor(s) licensed pursuant to the Contra&oes
License Law.
❑ I am exempt under Sec. B & P C for this reason
ter Date
WORKER'S COMPENSATION DECLARATION
I hereby affirm under penalty of perjury one or the following declarations:
❑ I have and will maintain a Certificate of Consent to self -insure for Worker's Compen-
sation, as provided for by Section 3700 of the Labor Code, for the performance of the
work for which this permit is issued.
❑ I have and will maintain Worker's Compensation Insurance, as required by Section
3700 of the Labor Code, for the performance of the work for which this permit is issued.
My Workers Compensation Insurance carrier and Policy number are:
Carrier. Policy No.:
CERTIFICATE OF EXEMPTION FROM WORKERS'
COMPENSATION INSURANCE
(This section need not be completed if the permit is for tint hundred dollars ($100)
or less.)
,
I certify that in the performance of the work for which this permit is issued, I shall not
employ any person in any m ne as toyecome subject to the Workers' Compensation
f ` ' O /
Laws of Califomi atc
Applicant [�L—
NOTICE TO A CANT. , after making this Certificate of Exemption, you should
become subject to the Workers Compensation provisions of the Labor Code, you must
forthwith comply with such provisions or this permit shall be deemed revoked.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of
the work for which this permit is issued (Sec. 3097, Civ. C.)
Lender's Name
Lenders Address
I certify that 1 have read this application and state that the above information is
correct. I agree to comply with all city and county ordinances and state laws relating to
building construction, and hereby authorize representatives of this city to enter upon the
above -mentioned property for inspection purposes.
(We) agree to save, indemnify and keep harmless the City of Cupertino against
liabilities, judgments, costs and expenses which may in any way accrue against said City
in consequence of the granting of this permit.
APPLICANT UNDERSTANDS AND WILL COMPLY WITH ALL NON -POINT
Issued by: Date
SOURCE RE,GW"TIONS.
� J�'���
fdl� -�
Re -roofs
Type of Rc of
Signature of Applicant/Contractor Date
HAZARDOUS MATERIALS DISCLOSURE
Will the applicant or future building occupant store or handle hazardous material
as defined by the Cupertino Municipal Code, Chapter 9.12, and the Health and Safely
—fie, Section 25532(a)?
All roofs s iall be inspected prior to any roofing material being installed.
❑Yes
If a roof is installed without first obtaining an inspection, I agree to remove
Will the applicant or future building occupant use equipment or devices which
emit hazardous air contaminants as defined by the Bay Area Air Quality Management
all new materials for inspection.
District?
❑ Yes
1 have read the hazardous materials requirements under Chapter6.95 of the Califor-
nia Health & Safety Code, Sections 25505, 25533 and 25534.1 understand that if the building
ii�j' f
does not currently have a tenant. that it is my responsibility to notify the occupant of the
/[iG, \
requirements which must be met prior to issuance of a Certifrc of Occupancy.
Signature e f Applicant Date
�� -_ 416 -07
All roof coverings to be Class "B" or better
'
Owner or authorized agent Date
May 14, 2007
Sue Winslow
City of Cupertino
Community Development Department
10300 Torre Avenue
Cupertino, (.;alifornia 95014
Re: Plan Review:
Address:
Cupertino Appl. No.:
Hello Sue,
Sinha SFD Addition
19780 Drake Drive
07020139
Per Bob Sabich's request we are sending back your file sets of drawings for
the above listed project. Bob will coordinate final approval with the
applicant.
Sincerely,
dD .
Berning
Architect
Bureau Veritas North A.nzerica, Inc. Alain; (925) 468.7400
6150 Stoncridgc Mall Road, Suitc 370 Fax: (925) 468.7413
Pleasanton, CA 94588-3241 «w.us.bureausrerirts.com
MHA Consulting Engineers Inc Pg2
1623 Wright Avenue 19780 Drake
Sunnyvale Ca 94087 4/26/2007
408-735-1524 -
DESIGN CRITERIA
CBC 2001/UBC 1997 BUILDING CODE
These calculations were performed from information provided on plans and computer
files labelled "Proposed RESIDENTIAL HOME ADDITION at 19780 Drake Dr
Cupertino, Ca," dated March 2007 by William Keller 61 Mulberry Ct Morgan Hill.
Any changes or modifications or revisions to the above mentioned plans and files
must be brought to the attention of the ENGINEER, and approval is required.
Failure of the client to obtain written approval for any changes or revisions etc, will
render these calculations void.
The client will then hold consultant harmless from any and all liability real or
alleged in connection with the performance of work on this project, except liability
arising from the sole negligence of the consultant.
A field construction review is recommended for the following: reinforcing steel, steel
frames, collectors and holdowns. In case the review is NOT performed by the
engineer of the original work, the client will hold the engineer harmless from any
liability, real or alleged, in connection with any portion of the above listed project.
MHA Consulting Engineers requires at least 48 hours notice for a field construction
review, please call 408-735-1524 for an appointment.
Any changes or modifications by the contractor during construction shall have prior
approval from the engineer before proceeding with the work.
All structural components such as beams,headers, columns,posts, rafters etc
shall be connected to each other using appropriate connectors by reputable
manufacturers such as "Simpson","Silver" and as noted in the plans.
All construction shall be in accordance with the requirements of the 1997 edition of
the Uniform Building Code and requirements of the local building authority
whichever is more stringent.
The following calculations will be considered void if:
Preceding notes, requirements and limitations are not accepted by the owner, his
designer, and his contractor in full.
1623 Wright Avenue
Sunnyvale Ca 94087
Ph# : 408-735-1.524
Fax : 408-733-1548
April 26, 2007
City of Cupertino
Building Divisi
}tfi
Attn: Doug Tal Plan'review Engineer.
Subject: 19780 Drake Drive, Sinha Addition. Structural comments.
Dear Sir,
The following are in response to your comments for the above property
Structural only.
S5 D) Please note that our general specification and details sheet S1 has all
The concrete and rebar information please see items 9 and 10 of
specifications on S1 for concrete strength and steel rebars.
S5 G) On detail 6/S1 we added H2.5 hurricane clips @ 4' on center.
S6 B) Your calculations booklet is missing some pages. The drawings and
calculations sent to you appear to be repackaged incorrectly. Attached are the
calculations for the 6x8 girder on page 8. The calculation were -complete as sent to
the city. 0% 1 1
The previous girder size sheet by the desigrTer Keller wefe ;4
never re -submitted, there should not have been s et showing 48.
Please check the sheets that you have.
S7 B) Deleted " clg joist hanger".
C) Detail B revised as per discussion with the review engineer.'
S8 B & C) discussed and responded as above.
If you have any questions please call.
Yours truly,
MHA Consulting Engineers Inc.
C -02
�r Exp. z '3S *
OF
05/08/2007 03:05 4087331548 MHA ENG INC
PAGE 01/02
MHA CONSULTING ENGINEERS, INC.
1623 WRIGHT "E.
SUNNYVALE, CA 94087-4038
PHONE: 408-735.1524
PAX: 408-733-1 ,48
E-MAIL mhaengi c@c*mcast.net
mina-mhaenyr@comcast.net
FAX COVER SHEET
DATE,.,
TO: b4y4r
FROM: 1\1i m ii(lat
PAGES (including cover page):
0
MESSAGE:
Mt. I�Y
05/08/2007 03:05 4087331548
MHA Consulting Engineers Inc
1623 Wright Avenue
Sunnyvale Ca 94087
408-735-1524
MHA ENG INC
JWm
l
�21 •tt•RDL + 841.8-psf I 2 2
T
_ (OTM — 0.9.1) L0.3•tt T = 692,277 lb Use PHD2 3600 lb
—
Redundancy calculation Shear Walls Vbase:= v
N/S dir Line B worst case Ab := Ar Ab = 472.5ft2
lw:= 8.5 Vw:= 3777•lb
Vbase:= 7554.1b
10 VW
[w Vbase
20-tt
P p = 0.436 take as 1.0
ri Ab
15 psf DL
Floor Joists L := 211 -ft L = 10.5 ft 40 psf LL
2
w:= 1.33.55•pif w = 73,15 lb—
ft
2
M := w 1= Sr := M Sr = 12.376 in
8 Pb•1.15
Use 2x8 @ 16" O,C, Sx = 13.14 in3 A = 10.88 in2
E := 1600000•psi I- 47.63-in4
4
A := 5•w• L A = 0.263 in L, = 479,973 deflection OK
384• E• 1 4
Girders L := 8-{t Max span
w:= zl •f1.55-psf w = 577.5 lb
2 ft
2
M := w• 8 Sr1 Sr = 50.4 in3
R := W. L R = 231 x 1031b Ar := R• 1•---5 Ar = 36.474 in
2 Fv
Use 6x8 Sx = 51.56 in3 A = 41.25 in2
PAGE 02/02
19780 Drake
4/26/2007
MHA Consulting Engineers Inc P99
1623 Wright Avenue 19780 Drake
Sunnyvale Ca 94087 NN 4/26/2007
498-735-1524
Foundation Design
No soils report use Table 18-1-A of CBC/UBC 1000 psf bearing allowable
Interior Piers 18"x18" Pads
P := 5.5•ft•6•ft•55•psf P = 1.815 x 103lb
A 2
1000•psf A = 1.815ft
D := �FA D = 16.167 in 18x18 in sq piers
Evaluate maximum strip capacity for concentrated load beyond which extra footing area is required
For 12 in wide base 18" HIGH STEM AND 12" DEPTH (MINIMUM SINGLE STOREY)
consider a 4.5 ft strip based on a 40/40 deg spread of load to base.
Pmax := 4.5•ft• 1 •ft• 1000•psf — 3•ft•350•plf Pmax = 3.45 x 1031b
Ave floor loading per ft
All col loads above 3.5 kips will require additional footing area
NO COL LOADS GREATER THAN THIS
Footing Rebar Design All square issolated footings are 12" thk installed to 18" depth
fc' = 2500 psi d=12-3 = 9" As=0.2 in 1 - # 4 rebar per ft
a := 0.2• 60 -in a = 0.471 in Conc beam stress block
(0.85•12.2.5)
As := 0.2-in2 Fy:= 60000-psi design with 2000 psf bearing force
12 in thick bases less 3 in cover
0Mn := 0.85.0.9-As•F • 9-in — a OMn = 6.705 x 103 lb ft Max Beam Bending
y 2 ) Capacity
Typical new footing rebars 1- #4 top & bot.
MHA Consulting Engi
1623 Wright Avenue
Sunnyvale Ca 94087
408-735-1524
Inc
Design Strip Footing
Pg10
19780 Drake
4/26/2007
F a = 1 x 103 plf Allowable perimeter loading per foot
Fpa := l-1000•plf P
Fps- - 1.333 x 103 lb with stress inc for Equake Loads
Fps := 1.1333•plf p ft
Worst case Line 1 NEW
ft lb
wdl := 15 psf 10.5 2 + 15•psf•8-ft+ 10-psf•21 •ft wdl=303.75ft
2
w 21 ll = 378
10.5 Ib
-
w►► := 16•psf• 2 -ft + 40•psf• 2 -ft ft
Fl := wdl + wll
Fl = 681.75 plf < Allowable Fpa = 1 x 103 lb
ft
UBC Eqn 12-9 T := 1900•1b
s
[(wdl + wll)•4.5•ft + 7 J FL = I.}04 10 = 1.333 x 103 lb
x ft 3 lb < Fps ft
FL := 4.5•ft
self wt of footing Fsw := 220-plf
Uplift check
FL := [(wdl + Fsw)-4.5•ft•0.9 — T] FL = 221.188 lb
NO UPLIFT
Check Line 2 Existing foundation
41 lb
wdl := 15•psf-20• ft + 8•psf•8-ft + 10•psf•2 ft wdl = 419 ft
2
41 ft 40 sf 20 . ft w11 = 564lb
lb
wll := 16•psf•2. 2 + p 2 ft
-
3 lb
FI 983 if < Allowable Fpa = 1 x 10 ft
FI := wdl + wll — p
UBC Eqn 12-9 T := 1000-lb
MHA Consulting Engineers Inc Pg11
1623 Wright Avenue 19780 Drake
Sunnyvale Ca 94087 4/26/2007
408-735-1524
[(wdl + wll)•4.5•ft + T] 3 lb 3 lb
FL. = FL = 1.205 x 10 — Fps = 1.333 x 10 —
4.5•ft ft ft
self wt of footing Fsw := 300•plf
Uplift check
FL := [(wdl + Fsw)•6•ft•0.9 — T] FL = 2.883 x 103lb NO UPLIFT
COLUMNS
Columns Capacity Calculations Sill to top double stub height 11 ft plate height -
4x4 Column lb
Ke := 1.0 le:= Ke-8•ft PSI := — d := 3.5•in b := 3.5•in
.2
to
Fc' := 1300•psi E'
E' := 1600000•psi c' := 0.8 FcE := 0.3
/d)
1 + FCE C1 + CFcEII 2 FcE
Fc := Fc'.
Fc' Fc' %IJJ Fc'
- -
2•c' 2•c' c'
Fc = 555.234 psi
Pall := Fc•b•d Pall = 6.802 x 103 lb
NO LOADS LARGER THAN THIS
all posts 4x4
MHA Consulting Engineers Inc Pg12
1623 Wright Avenue 19780 Drake
Sunnyvale Ca 94087 MR 4/26/2007
408-735-1524
STUD CAPACITY
exterior rear wall Line A , 8 ft fir to roof
H := 8-ft Sx := 3.063•in3 A := 5.25•in2
s := 16•in d := 3.5•in Ke := 1.0 le := Ke•H
0.3 • E'
Fc' := 1350•psi E' := 1600000•psi c' := 0.8 FcE :_
(d)
1e2
FcE FcE 2 FcE
t+l Fc' � 1+(Fc') Fc'
2•c' 2 c' c' Fc = 559.008 psi
Fb := 900•psi
Roof loading Worst case at Exterior wall Line 1
w := 21 • ft •25•psf lb
2.1.25 w=210—
ft
P := w•s P = 2801b fc := P fc = 53.333 psi
A
2
q :— 0.62.1.33.12.6.1.3•psf M := q s El fb := M Cr = 1.15
8 Sx•1.15
M = 144.074 lb ft
2 fb
fc + = 0.604 < 1.33 OK
Fc CFFcE)]
2x4 STUDS @ 16" O/C
MHA Consulting Engineers Inc Pg12
1623 Wright Avenue 19780 Drake
Sunnyvale Ca 94087 I 4/9/2007
408-735-1524
William Kellar
Drafting Services
61 Mulberry Court, Morgan Hill, CA 95037-6108
Phone (408)779-4492 Cell (408) 656-2974 a -mail: wskellar@verizon.net
April 23, 2007
Sue Winslow
City of Cupertino — Building Division
Community Development Dept.
10300 Torre Avenue
Cupertino, CA 95074
RE: Plan Review: Sinha SFD Addition
Address: 19780 Drake Drive
Cupertino Appl. No: 07020139
Permit #07020139
#2 Response to Comments dated 4-19-07
MAY 0 3 2007
Dear Ms. Winslow:
The following changes to our plans, as you requested, are not
Sheet 1 VFICE coy
1. Sheets # 3 and #6 have been revised to include the signatures you requested.
2. The plan Index has been amended to include "Department of Public Works" sheet.
Sheet 2
5. (A) Existing Bedroom #2 is to be converted to a Study/Den room. We are removing the (E)
closet and adding a 3'-0" wide by 6'-8" high, cased opening, into the (N) kitchen area. We are
removing window #6.
Notes: 1.) Removing closet will qualify the room as non -bedroom.
2.) (N) Study/Den is 144sf: Lighting (1 /10)= 14.4sf; Venting (1 /20)= 7.20sf
2'x 4' skylight = 8sf + 3' x 6'-8" C.O.=19.98sf; Total=27.98sf for lighting.
3.) 3' x 6'-8" C.O.= 19.98sf, Total=19.98sf for venting.
If 3'x 6'-8" cased opening does not qualify for natural light, then we will submit to an
operable skylight.
6. The existing Family/Dining rooms has 530sf of area: lighting= 53sf; venting= 26.5sf
Notes: 1.) An existing 2040 skylight has 8sf; a (N) 4050 sliding window has 20sf. In the
Family Room; an (E) 6030 sliding window is in the (E) kitchen/Dining room; a new
2050 sliding window will be added in Family Room. This equals 56sf for lighting.
2.) All windows for lighting = 48sf. This equals 48sf for venting.
Page 2
April 23, 2007
#2 Response to Comments dated 4-19-07
7. Floor plan note #6 has been amended per your request. I was not aware that the last note I
amended on note #6 explained that the landing could not exceed 7-1 /2". I drafted a small plan to
explain my intentions more clearly.
8. The existing Kitchen will be eliminated completely for the expansion of the existing Dining Room.
The plan will show the changes.
Electrical Plan
The Electrical plan has been modified per your request.
Mechanical and Plumbing plans are "Design Build", and will been submitted by the respective
contractors.
Structural plans and calculations are being amended by MHA Consulting Engineers, Inc., Moses
Haung, PE, CE.
Please note:
If architectural plans conflict with the structural plans, the structural plans shall prevail.
If you need to correspond with me, or if you have any question, please e-mail me at
William (Bill) Kellar
KELLAR CONST,
Ms. Winslow and Bureau Veritas North America, Inc.
In response to your comments on SINHA addition at 19780 Drake Dr.
Sheet#1-3
The city has already signed off as addition is under 500sf.
Sheet#2-9
As shown on first revised plans and on second revised plans
existing kitchen to be removed area no longer used as kitchen.
Sheet#8
Sheet 8 is not in revised plans. Electrical is on sheet 6.
Heating for new kitchen will come from existing heater which
is capable of heating new area as well as existing house.
Ducts are run through attic.
Water heater and funace are existing.
If you have any questions please contact me at--(408)867-9743
or '390-6991
Don Kellar
mrim uonsuiting Engineers Inc
1623 Wright Avenue J
CEIVED
Sunnyvale Ca 9408P,
408-735-1524
APR 112007
#2
AWNS
AM ;j
STRUCTURAL CALCULATIONS
FOR PROPOSED ADDITIONS AT
19780 DRAKE DRIVE
CUPERTINO , CALIFORNIA
FOR: SINHA RESIDENCE
Pg1
19780 Drake
4/9/2007
BY
MHA CONSULTING ENGINEERS INC
ti0 QROFESS�QN
C058
6M �omc#
�vx
mHH consulting Engineers inc Pg2
1623 Wright Avenue 19780 Drake
Sunnyvale Ca 94087 4/9/2007
MW
408-735-1524
DESIGN CRITERIA
CBC 2001/UBC 1997 BUILDING CODE
These calculations were performed from information provided o.`n plans and computer
files labelled "Proposed RESIDENTIAL HOME ADDITION at 19780 Drake Dr
Cupertino, Ca," dated March 2007 by William Keller 61 Mulberry Ct Morgan Hill.
Any changes or modifications or revisions to the above mentioned plans and files
must be brought to the attention of the ENGINEER, and approval is required.
Failure of the client to obtain written approval for any changes or revisions etc, will
render these calculations void.
The client will then hold consultant harmless from any and all liability real or
alleged in connection with the performance of work on this project, except liability
arising from the sole negligence of the consultant.
A field construction review is recommended for the following: reinforcing steel, steel
frames, collectors and holdowns. In case the review is NOT performed by the
engineer of the original work, the client will hold the engineer harmless from any
liability, real or alleged, in connection with any portion of the above listed project.
MHA Consulting Engineers requires at least 48 hours notice for a field construction
review, please call 408-735-1524 for an appointment.
Any changes or modifications by the contractor during construction shall have prior
approval from the engineer before proceeding with the work.
All structural components such as beams,headers, columns,posts, rafters etc
shall be connected to each other using appropriate connectorsby reputable
manufacturers such as "Simpson", "Silver' and as noted in the plans.
All construction shall be in accordance with the requirements of the 1997 edition of
the Uniform Building Code and requirements of the local building authority
whichever is more stringent.
The following calculations will be considered void if:
Preceding notes, requirements and limitations are not accepted by the owner, his
designer, and his contractor in full.
MHA Consulting Eng
1623 Wright Avenue
Sunnyvale Ca 94087
408-735-1524
Asphalt tiles
3.0 PSF
1/2 in Ply sheathing
1.5
Rafter and framing
2.5
Mechanical and Electrical
0.5
Insulation
1.5
Ceiling Board only
1.5
Tot DL = 7.5
Adjust for slope DL = 9 psf use 10 psf
LL = 16 psf
Total Roof Load = 25 psf
RF := 26-psf
TRUSS ROOF BY OTHERS
Main roof
19780 Drake
4/9/2007
lb lb psf :_ psi := lb — plf :_ b
ft
2 in
2 ft
Pitch of Roof approx
Main 7:12
� 5
Slopedlen := (72 + 122)
Slopedlen = 13.892
Ratio
Slopedlen
:_
12
Ratio = 1.158 j RDL := 10•psf
DF # 1 Fbl := 1100-psi Fv 95-psi
DF#2 Fb := 850-psi Fv := 95-psi
Glul-am 24F-V3 DF/DF Lam
Fbgl := 2400-psi Fvgl := 190-psi
i
Egl:= 1800000-psi,
RBI Ridge Beam L := 10-ft 21 lb:
w := --ft•RF w = 273 — ! 0 to w at end
2 ft!'
Strucalc output 2X12
CB1 Header Beam for RBI
L:= 6-ft P:= 931-lb P=931 lb
12.5 ft-RF lb
w = 162.5
w:= exsting roof rafters
2 ft
M := P- L M = 1.397 x 1031b ft R := + w- L R = 953 lb
4 2 2
M
Sr := Sr = 15.772 in3 Ar := 3 - R Ar = 15.047 in2
Fb.1.25 2 Fv
i
Use 4x8 Sx = 30.66 in3 A =25.38 in2
Multi -Loaded Beam( 2001 California Buildinq Code (91 NDS)1 Ver: 6.00.81
By: Nina Huang , MHA Consulting Engineers on: 04-09-2007 : 10:41:27 AM
Project: 19870 DRAKE - Location: RB1 rev
Summary:
1.51N x 9.25 IN x 10.0 FT / #2 -Douglas Fir -Larch -Dry Use
Section Adequate By: 19.7% Controlling Factor: Section Modulus / Depth Required 8.46 In
Center Span Deflections: dLD-Center=
Dead Load:
LLLD-Center=
Live Load:
Total Load: TLD-Center=
Center Span Left End Reactions (Support A):
Live Load:
Dead Load:
Total Load:
Bearinq Lenqth Required (Beam only, support capacity not checked):
Center Span Right End Reactions (Support B):
Live Load:
Dead Load:
Total Load:
Bearing Length Required (Beam only, support capacity not checked):
Beam Data:
Center Span Lenqth:
Center Span Unbraced Length -Top of Beam:
Center Span Unbraced Length -Bottom of Beam:
Live Load Duration Factor:
Live Load Deflect. Criteria:
Total Load Deflect. Criteria:
Center Span Loading:
Uniform Load:
Live Load:
Dead Load:
Beam Self Weight:
Total Load:
Trapezoidal Load 1
Left Live Load:
Left Dead Load:
Riqht Live Load:
Riqht Dead Load:
Load Start:
Load End:
Load Lenqth:
Properties For: #2- Douglas Fir -Larch
Bendinq Stress:
Shear Stress:
Modulus of Elasticity:
Stress Perpendicular to Grain:
Adjusted Properties
Fb' (Tension):
Adjustment Factors: Cd=1.25 Cf=1.10
Fv':
Adjustment Factors: Cd=1.25
Design Requirements:
Controllinq Moment:
5.8 Ft from left support of span 2 (Center Span)
Critical moment created by combining all dead loads and live loads
Controllinq Shear:
At a distance d from riqht support of span 2 (Center Span)
Critical shear created by combining all dead loads and live loads on
Comparisons With Required Sections:
Section Modulus (Moment):
Area (Shear):
Moment of Inertia (Deflection):
LL-Rxn-A=
DL-Rxn-A=
TL-Rxn-A=
BL-A=
LL-Rxn-B=
DL-Rxn-B=
TL-Rxn-B=
BL-B=
L2=
Lu2-Top=
Lu2-Bottom=
Cd=
U
U
wL-2=
wD-2=
BSW=
wT-2=
TRL-Left-1-2=
TRD-Left-1-2=
TRD-Right-1-2=
TRD-Right-1-2=
A-1-2=
B-1-2=
C-1-2=
Fb=
Fv=
E=
Fc_perp=
Fb'=
Fv'=
0.07
IN
0.12
IN = U963
0.20
IN = U603
292
LB
180
LB
472
LB
0.50
IN
583
LB
344
LB
927
LB
0.99
IN
10.0
0.0
10.0
1.25
360
240
FT
FT
FT
0 PLF
0 PLF
3 PLF
3 PLF
0 PLF
0 PLF
175 PLF
98 PLF
0.0 FT
10.0 FT
10.0 FT
875 PSI
95 PSI
1600000 PSI
625 PSI
1203 PSI
119 PSI
M=
1792
FT -LB
on span(s) 2
V=
740
LB
span'(s) 2
Sreq=
17.88
IN3
S=
21.39
IN3
Areq=
9.35
IN2
A=
13.88
IN2
I Ireq=
39.40
IN4
1=
98.93
IN4
MHA Consulting Engineers Inc AMON Pg4
1623 Wright Avenue 19780 Drake
Sunnyvale Ca 94087 MIN 4/9/2007
408-735-1524
Lateral Loads Analysis
Typical Shear Walls
Type A Wall 3/8" Ply CDX Sheathing Nails 8d @ 6" o.c. edges and 8d @ 12" o.c. field.
Allowable shear load 260 lb/ft Sall := 260• lb Nail single shear value 1-1/2 " Side 133%
ft Ns := 138.1b
Sill Plate Nails using 16d to 2x Joist or blocking
Nail Spacing s := Ns s = 6.369 in Use 5" o.c.
Sall
Simpson A34 Framing Clips SC := 345-lb
s := 360- (b s = 1.385 ft Use 16" o.c. wall stud spacing
Sall
2xPT Sill Plate with 5/8" anchor bolts s := 890.1.33• lb
Sall
s = 4.553 ft Use 41ft o.c.
Type B Wall 3/8" Ply CDX Sheathing Nails 8d @ 4" o.c. edges and 8d @ 12" o.c. field.
Sall := 350- lb Nail single shear value 1-1/2 " side member
Allowable shear load 350 lb/ft ft Ns := 138 lb
Sill Plate Nails using 16d to 2x Joist or blocking
Nail Spacing s := Ns s = 4.731 in Use 4" o.c.
Sall
Simpson A34 Framing Clips SC := 345-lb max load
s := 365. Ib
Sall
2xPT Sill Plate with 5/8" Anchor Bolts
s = 1.043 ft Use 12" o.c. roof joist spacing
s := 890.1.33• lb
Sall
s = 3.382ft Use 3 tro.c.
lb
psf := —
ft2
k:= 1'000•113
lb
psi := —
2
in
plf := ft
virim
uonsu
ting
1623 Wright Avenue
tngineers meANNE - Pg5
1623 Wright Avenue ' 19780 Drake
Sunnyvale Ca 94087 4/9/2007
ake
408-735-1524
No soils report use CBC/UBC table 1000 psf
Use Max Factor 1.5
R= 5.5 bearing wall shear panels, I = 1.0 Residence
Controlling Equation UBC 30-5 need not exceed this value
R := 5.5 Na := 1.5 I := 1
Ca := .44•Na Ca = 0.66 Wtot := 1
V := 2.5•Ca• i Wtot V = 0.3
R
V = 0.3 x W deadload
For ASD can use E/1.4 in Load Combinations
Roof RDL := 10•psf
Ar := (21.22.5)•ft2 New addition area Af := Ar
roof diaph + exterior walls int walls Walls exterior use 15 psf stucco wall
Wr := RDL•Ar + (2.25 + 2.26)•4.15•lb + (45)•4.8•lb Wr = 1.228 x 104lb
W := Wr W = 1.228 x 104lb
V := 0.3• W V = 2.632 x 103 lb Base shear ASD
1.4
Vr := V
Exposure B 70 mph winds
Cel5 := 0.62 Ce20 := 0.67 Ce25 := 0.72 Cq := 1.3
q := 12.6-psf pr := (Ce15.21.225)•ft2.q•Cq pr = 479.8521b
Longest side used
pwall := Ce]5•(21)•(8)•ft2 q•Cq pwall = 1.706x 103lb
p := pr + pwall p = 2.186 x 103 lb << V 2.6 k Seismic Lateral
shear force
Seismic controls
MHA Consulting Engineers Inc Pg7
1623 Wright Avenue 19780 Drake
Sunnyvale Ca 94087 4/9/2007
408-735-1524
1
RM := C25 •ft•RDL + 8•ft•8•psf I L 2
2 / 2
T (OTM — 0.9•RM)
T=2.012x 1031b
L — 0.3•ft
Use PHD2 3600 Ib
East West Add tributary from existing
Line 1
Vtribt := 121 28� ft2 10•psf Vtribt = 1.47 x 103
2 2 lb
Vr := Vwall + Vtribl Vr = 2.786 x 103 lb
L := 9-ft v := Vr v = 309,583 lb Type B 350 Ib/ff
L ft
OTM := 8-ft-Vr OTM = 2.229 x 104lbft
2
RM :_ (2•ft•RDL + 8-ft. 15-psf) 2
2
T (OTM — 0.9-RM) T = 1.976 x 103 lb Use PHD2 3600 lb
L — 0.3-ft
Line 2
Add tributary from existing
L := 14-ft
Vtrib2 := 2 . 21 •ft2.10•psf Vtrib2 = 1.732 x 103 lb
C
Vr := Vwall + Vtrib2 Vr = 3.049 x 103 lb
v := Vr v = 217.768 lb Type A 260 Ib/ft
L ft
OTM := 8-ft-Vr OTM = 2.439 x 104lbft
MHA Consulting Engineers Inc Pg8
Wright Avenue M 19780 Drake
Sunnyvalen Ca 94087 4/9/2007
408-735-1524
2
RM :_ I -ft•RDL + 8-ft•8•psf)• 2
T (OTM - 0.9 RM) T = 692.277 lb Use PHD2 3600 lb
L - 0.3•ft
Redundancy calculation Shear Walls Vbase:= V
N/S dir Line B worst case Ab := Ar Ab - 472.5 ft2
Iw := 8.5 Vw := 3777•lb
Vbase:= 7554-lb
10 VW
ri :_ —• ri = 0.588
Iw Vbase
20•ft
p := 2 - p = 0.436 take as 1.0
ri Ab
15 psf DL
Floor Joists L := 21 2 .ft L = 10.5 ft 40 psf LL
w := 1.33.55•plf w = 73.15 16
ft
L2 M
M := w•— Sr := Sr = 12.376 in3
8 Fb-1.15
Use 2x8 @ 16" O.C. Sx = 13.14 in3 A = 10.88 in2
E := 1600000•psi 1 := 47.63•in4
4
A := 5•w• L A = 0.263 in L = 479.973
384•E•I A
Girders L := 8-ft Max span
w := 21 ft-55-psf w = 577.5 lb
2 ft
L2 M
M := w-- Sr := — Sr = 50.4 in3
8 Fbl
R := w• L R = 2.31 x 103 lb Ar := R• 11.55 Ar = 36.474
2 Fv
Use 6x8 Sx = 51.56 in3 A = 41.25 in2
OK
MHA Consulting Engineers Inc P 10
1623 Wright Avenue 19780 Drake
Sunnyvale Ca 94087 mm
4/9/2007
408-735-1524
Design Strip Footing
Fpa := l-1000-plf Fpa = 1 x 103 plf Allowable perimeter loading per foot
Fps := 1.1333•plf Fps = 1.333 x 103 lb with stress inc for Equake Loads
ft
i
i
Worst case Line 1 NEW
wdl := 15-psf-10.5• ft + 15-psf-8-ft + 10-psf- 21 -ft wdl = 303.75 lb
2 2 ft'
wll := 16-psf- 21 .ft + 40-psf. 10.5 ft wll = 378 lb
2 2 ft
Fl := wdl + wll FI = 681.75 plf
UBC Eqn 12-9 T := 1900.1b
FL := [(wdl + wll).4.5-ft + T]
4.5-ft
self wt of footing Fsw := 220-plf
Uplift check
< Allowable Fpa = 1 x 103 Ib
ft
FL = 1.104 x 103 lb < Fps = 1.333 x 103 lb
ft ft
FL := [(wdl + Fsw)-4.5-ft-0.9 — T] FL = 221.188 lb
NO UPLIFT
Check Line 2 Existing foundation
wdl := 15.psf.20.ft + 8-psf-8-ft + 10-psf-41 -ft wdl = 419 lb
2 2 ft
wll := 16-psf-41.ft + 40-psf• 20•ft wil = 564 lb
2 2 2 ft
FI := wdl + wll FI = 983 plf < Allowable Fpa = 1 x j 03 lb
ft
UBC Eqn 12-9 T:= 1000-lb
r„ — vvuawuny c1IVII cia n'c P 9
1623 Wright Avenue 19780 Drake
Sunnyvale Ca 94087 MIN 4/9/2007
408-735-1524
Foundation Design
No soils report use Table 18-1-A of CBC/UBC 1000 psf bearing allowable
Interior Piers 18"x18" Pads
P := 5.5-ft-6-ft-55-psf P = 1.815 x 1031b i
P
A _1000-psf A = 1.815 ft
2
D := ti A
D = 16.167 in 18x18 in sq piers
Evaluate maximum strip capacity for concentrated load beyond which extra footing area is required
For 12 in wide base 18" HIGH STEM AND 12" DEPTH (MINIMUM SINGLE STOREY)
consider a 4.5 ft strip based on a 40/40 deg spread of load to
Pmax := 4.5-ft-1-ft-1000-psf - 3-ft-350-pif Pmax = 3.45 x 103 lb
Ave floor loading per ft
All col loads above 3.5 kips will require additional footing
NO COL LOADS GREATER THAN THIS
Footing Rebar Design All square issolated footings are 12" thk installed to 18" depth
fc' = 2500 psi d=12-3 = 9" As=0.2 in 1 - # 4 rebar per ft
a := 0.2- 60 -in a = 0.471 in Conc beam stress block
(0.85.12.2.5)
'
As := 0.2-in 2 Fy := 60000-psi design with 2000 psf bearing force
12 in thick bases less 3 in cover
(DMn := 0.85.0.9-As-Fy-9-in - a� q)Mn = 6.705 x 103lbft ;Max Beam Bending
2 Capacity
Typical new footing rebars 1- #4 top & bot.