07120087 - Energy TITLE 24 REPORT
Title-24 Report for:
Rafii Residence
10484 Byrne Avenue
Cupertino, CA 95014
Project Designer:
Reza Rafii
10484 Byrne Avenue
Cupertino, CA 95014
408-472-2591
Report-Prepared By:
Nicholas L. Bignardi
Frank R. lannucci, Energy Consultant
'21 N. Harrison Street, Suite 210
Campbell, CA 95124
(408) 866-1620
Job Number:
070968
Date:
.11/29/2007
The EnergyPro computer program has been used to perform the calculations summarized in this compliance report. This program has approval and is
authorized by the California Energy Commission,for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards.
This program developed by EnergySoft,LLC-www.energysoft.com.
EnergyPro 4,4 by EnergySoft. .'Job Number:070968 User Number 1315
EQUIPMENT LIST AND INSULATION PLACEMENT NOTE
NEW HOME FOR #070968
RAFII RESIDENCE
10484 BYRNE AVENUE
CUPERTINO, CA 95014
NOTE: MINIMUM HEATING AND- COOLING LOAD CALCULATIONS ARE GENERATED BY THE
COMPUTER PROGRAM. THERE, 'ARE .OTHER-DESIGN FACTORS THAT MUST BE CONSIDERED,
DUCT FLOW, COIL SIZING', .,OVERSIZING SAFETY MARGIN, ETC. IT IS THE
RESPONSIBILITY -OF THE MECHANICAL CONTRACTOR OR WHOEVER DESIGNS AND INSTALLS
THE HEATING AND COOLING SYSTEM-TO MAKE THE FINAL DECISION ABOUT THE SIZE OF
THE EQUIPMENT TO BE INSTALLED.
THE HVAC EQUIPMENT USED.-MUST MEET- THE EFFICIENCIES SHOWN IN THE TITLE 24
CALCULATIONS. THESE AREA'S FOLLOWS:
HEATING: NEW FURNACE (S) MUST HAVE AN AFUE OF . 80 OR BETTER. FURNACE (S)
MUST BE ABLE TO HANDL& THE HEATING LOAD.
AIR CONDITIONING: AIR-CONDITIONING TO BE INSTALLED MUST HAVE A MINIMUM SEER
OF 13.
SETBACK THERMOSTAT: A SETBACK THERMOSTAT IS REQUIRED FOR EACH NEW FURNACE.
HOT WATER HEATER: WE SHOW A 50-GALLON WATER HEATER IN OUR CALCULATIONS.
WATER HEATERS WITH AN EF OF . 58 OR LESS MUST BE WRAPPED WITH AN R-12
BLANKET. THE FIRST 5 FT:: OF PIPES FROM THE STORAGE TANK MUST BE INSULATED
WITH ONE INCH OF INSULATION FOR BOTH HOT AND COLD WATER PIPES . NEW PIPES
FROM THE WATER HEATER TO THE KITCHEN THAT ARE 0 . 75 IN. OR LARGER MUST BE
INSULATED WITH ONE INCH OF INSULATION.
NOTE: WEEN WRAPPING INSULATION AROUND A WATER BEATER THE MANUFACTURERS
DATA AND RECOMMENDATIONS.MUST BE FOLLOWED.,
FAUCETS AND SHOWERHEADS; SHOWERHEADS AND FAUCETS MUST BE ON
THE CEC APPROVAL LISTING -IN ORDER TO BE INSTALLED. THIS CAN BE CHECKED
THROUGH THE BUILDING DEPARTMENT ISSUING THE BUILDING PERMIT, THE CALIFORNIA
ENERGY COMMISSION 916-654'-4080, OR BY CALLING OUR OFFICE 408-866-1620.
INSULATION PLACEMENT:
INSULATION TO BE INSTALLED' MUST MEET CEC QUALITY STANDARDS.
SEE THE ATTACHED CROSS SECTION DRAWING FOR INSULATION PLACEMENT AND
R-VALUES.
FOR GLAZING U-L-FACTORS AND SHGC VALUES REFER TO THE CF-1R
0E THE-REPORT-
NOTE: ALL R-VALUES .AND U.VALUES'LISTED ARE MINIMUM VALUES AND CAN
BE EXCEEDED:
LIGHTING:
PERMANENTLY INSTALLED LUMINARIES LOCATED IN BATHROOMS, GARAGES, LAUNDRY
ROOMS, AND UTILITY ROOMS SHALL BE HIGH EFFICACY LUMINARIES OR ARE
CONTROLLED BY AN OCCUPANT SENSOR (S) CERTIFIED TO COMPLY WITH SECTION 119 (D)
PERMANENTLY INSTALLED LUMINARIES LOCATED OTHER THAN IN KITCHENS, BATHROOMS,
GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS SHALL BE HIGH EFFICACY LUMINARIES
(EXCEPT CLOSETS LESS THAN 70 FT) OR ARE CONTROLLED BY A DIMMER SWITCH OR
ARE CONTROLLED BY AN OCCUPANT SENSOR THAT COMPLIES WITH SECTION 119 (d) THAT
DOES NOT TURN ON AUTOMATICALLY OR HAVE AN ALWAYS ON OPTION.
HIGH EFFICACY LUMINARIES OTHER THAN OUTDOOR HID: CONTAIN ONLY HIGH EFFICACY
LAMPS AS OUTLINED IN TABLE 150-C, AND DO NOT CONTAIN A MEDIUM SCREW BASE
SOCKET (E24/E26) . BALLASTS FOR LAMPS 13 WATTS OR GREATER ARE ELECTRIC AND
HAVE AN OUTPUT FREQUENCY NO LESS THAN 20 kHz
LUMINARIES THAT ARE RECESSED INTO INSULATED CEILINGS ARE APPROVED FOR ZERO
CLEARANCE INSULATION COVER (IC) AND ARE CERTIFIED TO ASTM E283 AND LABELED
AS AIR TIGHT (AT) TO LESS THAN 2 . 0 CFM AT 15 PASCALS
WHEN IN DOUBT ABOUT MEETING THIS REQUIREMENT CALL
FRANK R. IANNUCCI, 408-866-1620 .
ALL FLUORESCENT BALLAST MUST BE APPROVED BY THE CEC, THIS CAN BE CHECKED
THROUGH THE BUILDING DEPARTMENT ISSUING THE BUILDING PERMIT, THE CALIFORNIA
ENERGY COMMISSION 916-324-3376, OR BY CALLING OUR OFFICE
408-866-1620 .
ALL REFRIGERATORS, REFRIGERATOR-FREEZERS AND FREEZERS MUST BE ON THE CEC
APPROVAL LIST THIS CAN BE CHECKED THROUGH THE BUILDING DEPARTMENT ISSUING
THE BUILDING PERMIT, THE CALIFORNIA ENERGY COMMISSION 916-324-3376, OR BY
CALLING OUR OFFICE 408-866-1620 .
TABLE DF CONTENTS
Cover Page 1
Table of Contents 2
Form CF-1 R Certificate of Compliance 3
Form MF-1 R Mandatory Measures Summary 6
Form WS-5R Residential'Kitchen L=ighting 8
HVAC System,Heating'and Cooling. Loads Summary 9
EnergyPro 4A by EnergySofl Job Number. 070968 User Number 1315
r
Certificate Of Compliance : Residential (Part 1 of 3) CF-1 R
Rafii-Residence 11/29/2007
Project Title Date
l
1048.4-Byrne.Avenue-Cupertino --
Project Atldress Building Permit#
_Frank R._Iannucci,-Energy_Consulta nt (408).866-1620 Plan ChecWDate
Documentation Author Telephone
Ener �rP_ro _ CA_Climate-Zone_04 Fleltiche�WDate
Comel ce Method climate Zone
TDV Standard Proposed Compliance
(kBtu/sf-yr) DesignDesign Margin
Space Heating 17.39 14.95 2.44
Space Cooling 8.19 11.48 -3.29
Fans 2.21 2.67 -0.46
Domestic Hot Water 14.35 12.81 1.54
Pumps 0.00 0.00 0.00
Totals 42.14 41.91 0.23
Percent better than Standard: 0.6%
BUILDING COMPLIES - NO HERS VERIFICATION REQUIRED
Building Type: X]Single Family [IAddition Total Conditioned Floor Area: 1,364 ft2
❑Multi Family ❑Existing+Add/Alt Existing Floor Area: n/a ft2
Building Front Orientation: (W)270 deg Raised Floor Area: 1,111 ft2
Fuel Type: Natural Gas Slab on Grade Area: 0 ft2
Fenestration: Average Ceiling Height: 9.0 ft
Area: 274 ft2 Avg. U: 0.42 Number of Dwelling Units: 1.00
Ratio: 20.1% Avg. SHGC: 0.42 Number of Stories: 2
BUILDING ZONE INFORMATION #of Thermostat Vent
Zone Name Floor Area Volume Units Zone Type Type Hgt. Area
HVAC System1-1 12-274 100_ Condifionetl_- ---Setback-- -_-8 ..___n/a
OPAQUE SURFACES Insulation Act. Gains Condition
Type Frame Area U-Fac. Cay. Cont. Azm. Tilt Y/N Status JA IV Reference Location/Comments
.Wall_ Wood--14. _0.102 -R-13_R0.0.-225. 90 A ❑New .0923 1stFloor
Wall- Wood- 14__0-102_R=13_-R--0.Q.-135-_901_ New 0923 1stFloor
.Floor_ Wood- 776._0.037_ R-19_J.t0.0_� 180 ❑ . _'New 20-A4 1stEloor
Wall-_ Wood- 66. _0-102._R-13._R-0.0_-270 0 IX ❑New 09A3 -1st-Floor
Wall- Wood- -168._0.102 _R--13--3-0.0._0. 90 IX ❑New 09-A3 1stFloor
Door- None- 17 _0.500__None--3-0.0__0_ 0 IXI ❑New 28-A4 1st Floor
Wall- Wood- 98._0_102_R--13--R-0.0_-90- 90 [XI ❑New 09-A3 1st-Eloor
Wall- Wood- --306. _0_102.-R-13._R-0.0_-180_ 90 AXI ❑New 09-A3 1st Floor
Roof- Wood__ -523._(1032 RAO._R-0.0_-2Z0. IXINew 01=A17 1stFloor
L4
.Floor Wood--335. _0.048.-R_ _li0-a-0_-180 ❑ 'New_ 21=A4 2nd-Eloor
Wall Wood-_ -104. _Q-1Q2._R_13.Ji0.0--270. 90 IX ❑New- 09A3-_- 2nd.Eloor _
Wall- Wood--255- -0102._R-13_J3=0.0.41 90 AXI ❑New .09-A3 2nd Floor
Wall- Wood_ _152._0.102.-R_13__R_OJ1_-90. 90 IXI ❑New 09-A3 2nd Floor
Wall_ Wood__ _48. _0.102 _RZ13._R-0.0_ 1180- 90 AXI ❑New 09-A3_ 2nd-Floor
Roof_ Wood_- =588-_0.032 _-R-30.__R-O.D.-270-0 IXIO ONew 01A77 2nd-Floor =
- - - - - ---- ❑ ❑ - -
_ ❑ 1:1 - ----- - -
cl
Run Initiation Time: 11129/0708:26:58 Run Code_1196353618
_-- -EnergyPro 4.4 by EnergySoft User Number.1315 Job Number: 070968 Page3 of 9
Certificate Of Compliance . Residential (Part 2 of 3) CF-1R
Rafii Residence 11/29/2007
-- - - -
Project Title Date
FENESTRATION SURFACES
True Cond. Location/
# Type Area U-Factor' SHGC2 Azm. Tilt Stat. Glazing Type Comments
- Window__Right_(SW)._12.5 0.400 NERC_0.40.NERC_225__90.New-Double.Non Metal-Clear Low.E_ 7st.Floor
2_ Window Rear (SE) 12.5 0.400 NFRC 0.40 NFRC 135 90 New Double Non Metal Clear Low E 1st Floor _
3_ Window _Front_(W)_ 40.0 _0.450 NFRC 0.45 NFRC 270 90 New Double Non Metal CI-ear Door L_ow-_1st Floor
4_ Window Front (W). 20.0 0.400 NFRC 0_40 NFRC 270 90 New gouble Non Metal Clear Low E 1st Floor
5_ Window Rear (E)_ 15.0 _0.400 NFRC 0.40 NFRC 90__90_New Double Non Metal Clear Low E_ 1st Floor _
6 -Window Rear-(E)-40.0 _0,450 NFRC 0.45 NFRC_90_ _90-New Double Non-Metal Clear-Door-Low--1st Floor
7_ Window___Rear_(E)__12,0 _0.400NFRC. 0.40 NFRC _90_ _90.New_Rouble Non_Metal-Clear-Low E _1 st.Floor
8 Window Right _-(S)- _27.5 0.400 NFRC 0_40 NFRC 180 90 New Double Non Metal Clear Low E 1st Floor
.9_ Window._Front_(W)._,O,O. _0 400.NERC. -40 NFRC_270__90-New-Double-Non Metal Clear-Low-E_.2nd.Floor_
10 Window_Front (W)-_6.0. _0.400.NFRC. 040.NFRC _270__90_New_Double.Non_Metal-Clear-Low_E 2nd Floor
11 Window_ Front (W)._6,0. _0.400.NFRC. 040 NFRC_270_ _90 New Double-Non Metal Clear_Low_E_2nd Floor
12 WindowLett_(N)_12.0 _0_400 NFRC 0.40_NFRC 0_ 90 New Double Non Metal Clear Low E 2nd Floor
13 Window-Lek_(N)._6.0. _0.400 NFRC._0.40.NFRC 0__90.New_Double.Non Metal Clear-Low-E_.2nd Floor
14 Window Rear (E)__10.0 _0.400 NFRC 0.40 NFRC_90_ _90_New Double Non Metal Clear Low E_ 2nd Floor
15 Window Rear (E)_ 40.0 0.450 NFRC 0_45 NFRC 90 90 New Double Non Metal Clear Door Low-2nd Floor
16 Window Rear (E)_ 4.0 0.400 NFRC 0.40 NFRC 90 90 New bouble Non Metal Clear Low E_ 2nd Floor
1-Indicate source either from NFRC or Table 116A. 2.Indicate source either from NFRC or Table 1168.
INTERIOR AND EXTERIOR SHADING Window Overhang Left Fin Right Fin
# Exterior Shade Type SHGC Hgt. Wd. Len. HgL LExt. REM, Dist. Len. Hyl. Dist. Len, Hgt.
1 Bug Screen 0.76
2 Bug Screen 0.76
3 ug Screen 0.76
_ 4 Bug Screen 0.76
5_ Bug Screen 0.76
6 Bug Screen 0.76
7 - Bug Screen 0.76
- 8 Bug Screen_ 0.76
9 Bug Screen 0.76
10 Bug Screen 0.76
11 Bug Screen 0.76
12 Bug Screen 0.76
13 Bug Screen 0.76
14 Bug Screen 0.76
15 Bug Screen 0.76
16 Bug Screen 0.76
THERMAL MASS FOR HIGH MASS DESIGN
Area Thick.Heat Inside Condition Location/
Type (so (in.) Cap. Cond. R-Val. JA IV Reference Status Comments
PERIMETER LOSSES Insulation Condition Location/
Type Length R-Val. Location JA IV Reference Status Comments
j Runlnitiation Time: 11129/0708:28:58 Run_Code:_1196353618
EnergyPro 4.4 by EnergySoft User Number.1315 Job Number 070968 Page:4 of 9
Certificate Of Compliance Residential (Part 3 of 3) CF-1 R
_Rafii Residence 11/29/2007
Project Title Date
HVAC SYSTEMS
Heating Minimum Cooling Minimum Condition Thermostat
Location Type Eff Type Eff Status Type
HVAC System Central Fumace 80%AFUE Split Air Conditioner 13.0 SEER New Setback
HVAC DISTRIBUTION
Duct Duct Condition Ducts
Location Heating Cooling Location R-Value Status Tested?
HVAC System Ducted Ducted Attic 6.0 New No
Hydronic Piping Pipe, Pipe Insul.
System Name Length Diameter Thick.
WATER HEATING SYSTEMS Rated Tank Energy Tank Insul.
Water Heater #in Input Cap. Condition Factor Standby R-Value
System Name Type Distribution Syst. (Btu/hr) (gal) Status or RE Loss(%) Ext.
A O Smith Water Products XGV-50 Small Gas All Pipes Ins 1 40,000 50 New 0.63 n/a n/a
Multi-Family Central Water Heating Details,
Hot Water Pump Hot Water Piping Length U Add 1/2"
Control # HP 'Type In Plenum Outside Buried Insulation
REMARKS
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and specifications needed to comply with Title 24,Parts 1 and 6 of the California Code of
Regulations,and the administrative regulations to Implement them.This certificate has been signed by the individual with overall design responsibility.
The undersigned recognizes that compliance using duct design,duct sealing,verification of refrigerant charge and TXVs,insulation installation quality,
and building envelope sealing require installer testing and certification and field venfication by an approved HERS rater.
Designer or Owner (per Business&Professions Code) Documentation Author
Name: Name: Nicholas L.Bignardi
Title/Firm: Reza Rafii Title/Finn: Frank R lannucci Energy Consultant
Address: 10484 Byrne Avenue Address: 21 N.Harrison Street Suite 210
Cupertino CA 95014 Campbell CA 95124
Telephone:408-472-2591 Lic.#: Telephone:(408)8661620
X9/97
(signature) - (date) signature) (date)
Enforcement Agency
Name:
Title/Finn:
Address:
Telephone:
(signature) (date).
Run Initiation Time: 11129/07 08,26,58 Run Code: 1196353618
EnergyPro 4.4 by EnerQy5oft User Number,1315 Job Number. 070968 Page:5 of 9
Mandatory-Measures Summary: Residential (Page 1 of 2) MF-1 R
NOTE: lowrise residential buildings subject to the Standards.must contain these measures regardless of the compliance approach used. bore stringent compliance
-
requirements from the Cenificate of Compliance superoede the items marked with an asterisk(")below. Men this checklist is incorporated into the permit
documems,the features noted shall be considered by,an parties as minimum component performance specifications for the mandatory measures whether
they are shown elsewhere in the dooumems or on this oheoklim only.
DESCRIPTION 'Check or.Ihill al applicable boxes or chec k NA if not applicable and 1 no[uded with the ENFORCE.
permltappllcationdooumerdallon. N/A DESIGNER MENT
Building Envelope Measures
y 150(a): Mnimum R•12 in wood ceiling Insulation or equivalent U-factor in metal frame ceiling. ❑ ❑x ❑
1 150(b): loose fill insulation marerfacturees labeled R-Value: ❑ ❑x ❑
.1 150(c): Mnimum R-13 wall insulation in wood framed wags or equivalent U-tactor in metal frame walls(does not ❑ ❑% ❑
apply to exterior mass walls).
11 150(4): Mnimum R-13 raised floor insulation in framed floors or equivalent U-factor. ❑ ❑X ❑
1150(e): Installation of Fireplaces,Decoradve Gas Appfiances and On logs.
1.Masonry and factory-built fireplaces have:
a. closable metal or glass door covering the entire opening of the firebox- ❑ M ❑
b. outside air Intake with damper and eomrol,flue damper and control ❑ ❑x ❑
2.No continuous burning gas pilot lights allowed.. ❑ � ❑
150(1): Ar retarding wrap installed to comply wall 151 meets requirements specified in the ACM Residential Manual. I� ❑ ❑
1150(g): Vapor banters mandatory In Climate Zones 14 and 18 only. ® ❑ ❑
1 1500): Slab edge insulation-water absorption tae forthe insulation alone without facings no greater than 0.3%.water vapor ❑ ❑X ❑
penneance rate he gremerthan 2.0 pemutnch.
1 118: Insulation specified or installed meets Insulation installation quality standards. Indicate type and include ❑ ❑>< ❑
cr-BR Form
1 110.17: Fenestration Products.Exterior Odors,and Infiaration/Exfihration Controls.
1. Doors and windows between conditioned and unoondaioned spaces designed to limb air leakage: ❑ Il ❑
2. Fenestration produces(except field fabricated)have label with certified 1.1-Factor.certified Solar Heat Gain El ❑ El
(SHOC),and infiltration bendficalon.
3: Exterior doors and windows wentherstdpped;all joints and penetrations caulked and sealed. ❑ Il ❑
Space Conditioning;Water Heating and Plumbing System Measures
1 110.13: HVAC equipment,water heaters.showerheads and faucets certified by the Energy Commission. ❑ 0 ❑
1150(h):Heating andlor cooling loads caloubsied A acoordanoe whh ASHRAE,SMACNAor AC CA ❑ ❑x ❑
11500k Setback thermostat on an applicable heating and/or coo0ng systems. ❑ ❑x ❑
1 1500k UUrter system pipe and tank bnsubad on and cooling systems Fine insulation:
I.Storage pas water heaters rated with an Energy Factor less than 0.58 must be externally mapped with insulation ❑ ❑x ❑
having an installed thermal resistance of R-12 or greater.
2.Back-up tanks for sola systems;unfired storage tanks,a other indirect hot watertanks have R-12 external ❑ I� ❑
insulation or'R-18Internal insulation and indicated on the imenor o1 the tank showing the R-vakne.
3.The following piping is Insulated according to Table 150-AtB or Equation 150-A Insulation Thickness:
1.First 5 feet o1 hot and cold water pipes closest to water he nertank,non-recirculating systems.and entire ❑ El ❑
length of raohoulati g sections of hot water pipes shall be insulated to Table 1508.
2.Cooling system piping(suction,chilled mate.or brine fines}piping insulated between heating source and ❑ ❑x ❑
indirect hot watertank shag be insulated to Table 150-B and Equation 150-A
4.steam hydranic heating systems or hot water systems o 15 psi,meet requirements of Table 123-A ® ❑ ❑
5.Insulation must be protected from damage.Incknding that due to sunlight,moisture,equipment maintenance. ❑ ❑x ❑
and wind. -
d.Insulation for chilled water.piping and refrigerant suction piping includes a vapor retardant or is enclosed ® ❑ ❑
eminely In conditioned space.
7.Solar water-heating systems/collectors are certified by the Solar Rating and Certification Corporation. ® ❑ ❑
Energy Pm 4.4 by Energy Soft User Number:1315. .lob Number:070988 Page:a of 9
Mandatory Measures:Summary: Residential (Page 2 of 2) MF-1 R
NOTE: Lownse residential buildings subjeot to the Standards 1.must contain these measures regardless of the compliance approach used. Nitre stringent compliance
requirements from the Certificate,of Compliance superoede the hems marked with an asterisk(')below. Men this checklist is incorporated into the permit
documents,the features noted shall be tons ldered by all parties as minimum component performance specifications forthe mandatory measures whether
they are shown elsewhere In the documents or on this oheoklist only.
DESCRIPTION hnstrucllons:'Cheek or Initial applicable boxes when completed or chec k N/A if not ENFORCE-
DESCRIPTION , - NIA DESIGNER MENT
Space Conditioning,Water Heating and-Plumbing System Measures: (continued)
1150(m): Ducts and Fans
I duns and plenums installed:sealed and insulated to meet the requirements of the CMC Sections 601.602.803.60'0 X❑ ❑
605,and Standard 0-5;supply-air and return-aa ducts and plenums are insulated to a minumum installed level of
R-4.2 or enclosed entirelj.in conGaioned space: Openings shall be sealed with manic,tape or other duct-closure system
that meets the applicable requirements ofUL 181;UL 181A or UL 1810 or aerosol sealam that meets the requirements
of UL 723.,If mastic or tape is used to seal openings greaterthan 114 inch.the combination of mastic and either mesh or
tape shall be used.
2.Building cavities,support platforms for ur handlers,and plenums defined or cronstructed with materials other than sealal-JIIS-II
X❑ ❑
sheet meal;duct board or,flexlble duel shag not be used for conveying conditioned ale.Building cavities and support
platforms may contain ducts.Ducts installed M cavities and support platforms shall not be compressed to cause reductions
in the cross-sectional imi of.the ducts.-
3.Joints and seams o1 due systems and their components shall nit be sealed with cloth back rubber adhesive ❑ %❑ ❑
dun tapes unless such tape is used In combination with manic and draw bands.
4.Exhaust fan systems have back draft or automatic dampers. ❑ ® ❑
5.Gravity wrailaing system's serving conditioned space have either automatic or readily accesstble.manually operating❑ ® ❑
dampers.
8.Protection of Insulation.'InsuWion shall be protected from damage.including that due to sunlight.moisture,equipment❑. El ❑
maintenance,and mind.Cellular foam b udartion shall be protected as above or painted with a coating that is water
retantant and provides shielding from solarredrAion,that can came degradation of the material.
7. Flexible ducts cannot have porous inw cores. El ® ❑
1114: Pool and Spa Heating'Systems and Equipment
1:Athermal efficiency that complies with the OPp6rioe Efficiency Regulations,on-off switch mounted outside of the ® ❑, ❑
heater,weatherproof operating Instructions;no electric resistance heating and no pilof light..
2.System is installed with:
a.A lean38"of pipe between filter and hemer.for future solar heating. ® ❑ ❑
b.Cover for out pools or outdoor spas. ® 11 Elr t
3.Pool system has Qrenlonal Was and a circulation pump time switch. ® ❑ ❑
115 Gas fired fan-type ctkml furnaces.goof heaters.spa hostess or household cooking appliances have no continuously ❑ ® ❑
burning plot light.,(Exception:Non-electrical cooking appliances with pilot 4 150 Btu)hy)
1118(): Cool Roof material meets speoified or fteria ® ❑ ❑
Lighting Measures
1150(k)1:HIGH EFFICACY'LUMINAIRES OTHER THAN OU-DOOR HID:contain only high efficacy lamps as outlined in Table ❑ ® ❑
150-C,and do not contain a mediumscrew basesooket(12241F28). gallant for lamps 13 Wars or greater are electric
and have an output frequency.no less than 20 kHz. .
150(k)1:HIGH EFFICAC Y,LUMIRAIRES- OUTDOOR HID: ooraain only high efficacy lamps as outlined in Table 150-C. ❑ a❑ ❑
luminaire has factory installed HID ballast.
150(k)2:Permanently installed luminaires In kitchens shall be high efficacy luminaires. Up to 50%of the Wastage,os determined❑ ® ❑
in Section 130(c),of permanently Installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires,
provided that these luminaires are controlled by.switches separate from those controlling the high efficacy luminaires.
150(k)3:Permanently Installed luminaires In bathrooms;garages,laundry rooms,utility rooms shall be high efficacy luminaires. ❑ ❑K ❑
OR are controlled by an occupant sensors)cenfied to comply with Section 119(d}
150(k)4:Permanent!
installed luminaires located etnerthan in I itchens bathrooms.garzapes,laundry moms,and utility rooms
shall be high efficacy luminaires(except closes less than 70 ft)OR are contmled by a dimmer switch OR are controlled❑ lia ❑
by an 000upant sensor that complies u6;Sectlon I IBM tha5 does not tum on automatically or have an always on option.
150(k)5:luminaires that are recessed into insulated ceilin s are approved for zero clearance insulation cover(IC)and are ❑ ® ❑
certified to ASTM E283; IabelM a airtight(Ale to Mss than 2.0 CFM m 75 Pascals.
1150005.Luminaires providing outdoor lighting and permanently mounted to a residential building orto other buildings on the ❑ ® ❑
same lot shag be high efficacy luminaires(w including lighting around swimming at
poolsAvater failures or other Orticle 680
locations)OR are controlled by.occupant sensors with integral photo control certified to comply with Section I Ig(d}
1150(k)7:Lighting for parking lots for 8 or mole whines shag haw lightithat complies with Sections 130.132,and 147. ® ❑ El
Ughtng for parking garages for 8 or more vehicles shag have living that complies with Section 130,131,and 148.
1 I50(k)B:Permanently enalled lighting in this enclosed:non-0uie8ng spaces of low-rise residential buildings with four or more ® ❑ ❑
dwelling units shelf be high efficacy IuMrelres OR are controlled by occupart senscr(s)certified to comply with Section 119(d}
5nergyPm 4.4 by EhergySoft User Number 1315 Job Number.0711968 Page:7 of 0
Residential .Kitcherrtighting Worksheet WS-5R
Rafii Residence _ 11/29/2007
Project Title Date
At least 50%of the total rated wattage of permanentiyInstalled luminaires In kitchens must be In luminaires that are high efficacy luminaires
as defined In Table 150-C.Luminelres'that are not high efficacy must be switched separately.
Kitchen Lighting Schedule;' Provide the following Information for all luminaires to be Installed In kitchens.
High Efficacy
Luminaire Type High Efficacy? Watts Quantity Watts Other Watts
Yes No x = or
Yes I No I I x = or
Yes I No x = or
=Yes. No x = or
Yes No x = or
Yes No x = or
Yes No I I x = or
Yes No I I x = or
Yes I No I I x = or
Yes I No I I x = or
:Yes No I x = or
Yes No I x - or
Yes No I x = or
Yes No I x = or
Yes No x = or
Yes No. x = or
Yes No x = or
Yes No x = or
Yes No x = or
Yes I -No x = or
Total A: 0 B: 0
COMPLIES IF A Z B YES FX1 NO❑
EnergyPro
4,4 by EnergySoft User Number 1315 Job Number: 070968 Page:8 of 9
HVAC SYSTEM HEATING AND COOLING LOADS SUMMARY
PROJECT NAME DATE
_ _R_afi_i Residence _ _, 11/29/2007
SYSTEM NAME FLOOR AREA
HVAC System 9 1 —
-,364 1
ENGINEERING CHECKS 1 SYSTEM LOAD
(Number of Systems 1 COIL COOLING PEAK [COIL HTG. PEAK
Heating System CFM Sensible Latent I CFM I Sensible
Output per System D Total Room Loads F 650 8,973 1,480 485 19,761
Total Output(Btuh) 0 Return Vented Lighting of
Output(Btuh/sgft) 0.01 Return Air Ducts 1,5521 1,999
Cooling System Return Fan 1 01 0
Output per system _ 30,000 Ventilation o 0 o 9 0;_ of
Total Output(Btuh) l 30,000 Supply Fan 9 0,
Total Output(Tons) 2.5 Supply Air Ducts 1 1,5521 119991
Total Output(Btuhlsgft) 22.0 TOTAL SYSTEM LOAD —�
22,077, 1,480
Total Output(sgfllTon) 545.5
Air System HVAC EQUIPMENT SELECTION
1 CFM per System 855
Default 80%(13 SEER) 28,0421 O
Airflow(cfm) 855 0,
Airflow(chNsgft) 0.63
Airflow(cfm/Ton) 342.0
Outside Air(i) 00 Total Adjusted SyslemOutput 28042 0 � 0
(Adjusted for Peak Design Conditions)
Outside Air(cfmisgft) 0.00 TIME OF SYSTEM PEAK Aug 2 pm 9 Jan 12 am
Note:values above given at ARI conditions
EATING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Heating Peak
28.0°F 67.8°F 67.8°F 110.0°F
Supply Air Ducts
is
Outside Air
0 Cfm Supply Fan Heating Coil 1078 OF
855 cfm ROOMS
70.0 OF
67.8 OF
Return Air Ducts 'E
OOLING SYSTEM PSYCHROMETRICS Airstream Temperatures at Time of Cooling Peak
87.1/67,5°F79.7/60.4°F 79.7/60.2°F 49.2/47.5°F
Supply Air Ducts
Outside Air
0 cfm Supply Fan Cooling Coil 50.9148 3 of
855 cfm - 33.5% R.H. ROOMS
79.7/60.4 of 78.O0i 59.8 F
Return Air Ducts 'E i
_ EnergyPro 4.4 by EnergySofl User Number.1315 Job Number 070968 Page:9 of 99 J