Loading...
12080128 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 19980 PORTAL PLZCONTRACTOR:FRANK FIALA ROOFING PERMIPI'NO: 12080128 INC OWNER'S NAME: NAM& IIYUN CHO 1228 QUARRY LN STE C DATE ISSUED:08/132012 OWNER'S I'IIONE: 4088737133 PLEASAN I'ON.CA 94566 PUONE NO:(925)484-0124 ❑ LICENSED CONTRACTOR'S/ DECLARATION BUILDING PERMIT INFO: BLDG r ELECT r PLUMB License Class C r5G 39 I.ic.# (�J7O7 r r /y" ",, //,r' / MECH RESIDENTIAL COMMERCIAL Contractorrr / A ( +d'/& Date I hereby affirm that I am licensed under the provisions of Chapter 9 JOB DESCRIPTION:REMOVE BUILT-UP ROOFING AND INSTALL 5.33 SQS (commencing with Section 7000)of Division 3 of the Business&Professions NEW Code and that my license is in full force and effect. IR'CDS PLYWOOD;INSTALL I/4"DENS DECK;REPLACE FLASHING;INSTALL NEW CLASS A DURO-LAST ROOFING I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. I have and will nminutin Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.it Floor Area: Valuation:$7381 APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is AI'N Number:36945002..00 Occupancy'type: correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save indemnify and keep harmless the City of Cupertino against liabilities.judgments, PERMIT EXPIRES IF WORK IS NOT STARTED costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,the applicant understands and will comply WITHIN 180 DAYS OF PERMIT ISSUANCE OR with all non-point source reg atims per he Cupertino Municipal Code,Section 180 DAYS FROM LAST CALLED INSPECTION. 9.18. Signature itL Date g'1.772— Issued Date: e —vJ �Q ❑ OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's license Law for one of RE-ROOFS: the following two reasons: All roofs shall be inspected prior to any roofing material being installed.If a roof is I,as owner of the property,or my employees with wages as their sole compensation, installed withma first obtaining an insp 'tion,I ag to remove all new materials for Will do the work,and the structure not intended or offered Ibr sale(Sec.7044, inspection. . Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to Signature of Applicant: /,{ Date: -g- /Z construct the project(Sec.7044,Business&Professions Code). I hereby affirm under penalty of perjuryone of the following three ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER declarations: I have and will maintain a Certificate of Consent to self-insure for Worker's HAZARDOUS MATERIALS IyISCLOSURI? Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. I have read the hazardous materials requirements under Chapter 6.95 of the I have and will maintain Worker's Compensation Insurance,as provided for by California Ilcalth&Safety Code.Sections?5505.25533.and 25534. I will maintain Section 3700 of the labor Code,for theperformance of the work for which this compliance with the Cupertino Municipal Code.Chapter 9.12 and the Health& Safety Code,Section 25532(a)should I store or handle hazardous material. permit is issued. Additionally,should I use equipment ur devices which emit hazardous air I certify that in the performance of the work for which this permit is issued-I shall contaminants as defined by the Bay Area Air Quality Management District I will not employ any person in any manner so as 10 become subject to the Worker's maintain compliance with the Cupertino Municipal Code.Chapter 9.12 and the Compensation laws of California. If,after making this cenificate of exemption.I Health&Safety Cps e.Secti s 25505.25533.and 25534. become subject to the Worker's Compensation provisions of the Labor Code.I must forthwith comply with such provisions or this permit shall he deemed revoked. Owner or ull ed age ^/�12.— / Dale: APPLICANT CERTIFICATION CONSTRUCTION LENDING AGENCY I certify that I have read this application and state that the above inMrnuuion is --- correct.I agree to comply with all city and county ordimmees and state laws relating I hereby affirm that there is a construction lending agency for the performance of work's to building construction,and hereby authorize representatives of this city to enter for which this permit is issued(Sec.3097,Civ C.) upon the above mentioned property for inspection purposes.(We)agree to save Lender's Name indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses Which may accrue against said City in consequence of the Lender's Address granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section AI4CI11'I'FCI"S DECLARATION 9.18. I understand my plans shall be used as public records. Signature Date Licensed Professional CITY OF CUPERTINO \f/ FEE ESTIMATOR— BUILDING DIVISION ADDRESS: 19980 Portal Plaza (Bldg L) DATE: 08/13/2012 REVIEWED BY: Sean APN: BP#: l0212 (c0/02_ $ *VALUATION: $7,381 *PERMIT TYPE: Minor Building Permit PLAN CHECK TYPE: Re-roof PRIMARY Building is PENTAMATION USE: Multi-Family Dwelling >3 Stories 0 Yes ® No PERMIT TYPE: IR2ROO A WORK Remove built up roofing-and install new 1/2" CDX plywood; install 1/4" Dens Deck; replace flashing and SCOPE install new Class A Duro-Last roofing system (see ESR-1660). FEE ID ROOF AREA (s.f.) [ 1REROOFMRES 533 Atcch.Plop Ciwck Plumb.that Check _ Elec.Plan Check Mech. Permit Fee: Plumb.Permit Fre: Elec.Penn?:Fee: Other Mech.Insp. Other Plumb Insp. Other Elec.Insp, I rilcch, Insp.Fee: Plumb.Insp. Fee: Elec.insp. Fee: NOTE: This estimate does not include fees due to other Departments(Le. Planning, Public Works. Fire,Sanitary Sewer District,School District,etc:). These fees are based on the preliminary information available and are only an estimate. Contact the Dept for addn 7 info. FEE ITEMS (Fee Resolution 11-053Elf. 7/1/11) FEE QTY/FEE MISC ITEMS Plan Cheek Fee: .Supp/. PC Fee Plump:Aleeh.%Elec Permit Fee: $90.00 Supp'. /asp Fee Plumb.Mech.i Elec Phrmb./Mec•h./Elec•Permit Fee: Construction Tux: • I dntinistrwive Fee.: Work Without Permit? 0 Yes ® No $0.00 Advanced Planning Fees: Travel Documentation Fees: 4 Strong Motion Fee: 1BSEISAIICR $0.74 Select an Administrative Item Bldg Stds Commission Fee: 1BCBSC $1.00 SUBTOTALS: $91.74 $0.00 TOTAL FEE: $91.74 Revised: 07/01/2012 w' 1 . REROOF PERMIT APPLICATION tint:, COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION I•• • • e 10300 TORRE AVENUE • CUPERTINO, CA 95014.3255 / 7 CUP.ERTINO (408) 777-3228 • FAX (408)777-3333••buildinq(ahcupertino.orq / Cif0/CF PRrHUCr ADORR's/99Rn,{.I�PoIa/.a-.P1e1.. Pts Bid lL�J ,[y/PAPN.^/ 2\2/_ /J y5 OO /� ON:NI.Rw 1 t�i 6 L 14KN &4o ' �I Ptik• V 3 70.3 ((� /L y�e'koe' V10Y1fa• CID di STREET ADi !•?to n0� pI 42_,A. 2 Crjcl'._STATLG ICi� �b ��� T U I FAX _ CONTACT NAMES uIR' M ours ��k--�•F�'�/-o,2Y Gl\ i�/a rvor%u�.�sbcj10h1J•►�: STRjjfs oust r y Lig J e.. C IRSTATr.,].IP / �, CA- gys�G • ?is-y a7s2 0 U/WNER OV❑ OWNER-BUILDER 0 OWNER AGENT I. -CONT AcroR O•COWTEACTOR AGENT 0 ARCHITECT ❑ ENGINEER 0 DE-\'1!LUI•IIN ❑'nYANr CONTRACTOR NAME LICENSE NUMBI LICENSE'rYPIj�- IWS •1 •9 �-rcL1�1� �a�� � � /��/ 39L CO,.� rApp%"v-.- l-kcL.1c;. BOG\tY*_1 C (\c TATE.IP, a.lwftaon�in esbc9/o6.l•twi(tI 'a5 'E SN. 27S �1 l UDR UArr4 It,rNe li- L-- rlesasa (\ on Il A q`IS(,:.(a • I 45,44,4 -(eta-( ARCHFTET/ENONEER NAME LICENSE NUMBER I UUS.LIC.a COMPANY.NAME E-MAIL I FAX STREET ADDRESS CITY.STATE,ZIP PHONE USE OF 0 SFD Or Duplex Multi-Family ROOF AREA: VALUATION: smut-rum: 0 Commercial 533 SQ--r. $73 it r I EXISTING ROOF TYPE: c.BUILT-UP ROOF 0 ASPHALT SI(INGLES 0 WOOD SHAKES 0WOO 0SIIINGLES O OTHER(SPECIFY) RIi;.10VE/REPLACE - YES IF NO. PLYWOOD ' .w 0 PLYWD �0�-/OSB PITCH: RIRIF •NO M LAYERS' THICKNESS'. 0 s/S" TYPE' St CDX IT�-C ')0 CLASS. A PROPOSED ROOF TYPE: 0 BUILT-UP ROOF O ASPHALT SHINGLES 0 WOOD SHAKES ❑WOOD SHINGLES OTIIERf. IJ'�4ILti It1:I'ol{T4 P (t-Lila 1tO(r0 ecklPnoN OF WORK: V,eYrnovQ... old .6.4J1.'1t. ."—r\ z k itupp4" C. (1/44 ever Gf.Lsl- ,n,— ?Wt,vocck• 1.V•Sk-,al4 '/4 i1 be.ns tr`e,l;. -Klee:Lk-Or-3 Sktc.c-o a s Ates l f ile_ V-90 #9...00-C' �trt_ c . �4\ c1 ,icli.ny. Er&LAsu r�ei .C;\as; A u.1 o 1- l�S} � O flcc S,�Skkvi — 50 m; I. e V C,-'4-tlumo p I4s EL•c. By Inv signature below,I certify to each of the fol owing: I am the propeny owner or authorized agent to act on the property owner's behalf. I have read this applii-ation and the information I have provided is correct. av•read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and slate laws relating t. .w. ing cc-rsgucuo I n r c r•presenlalives of Cupenino to enter the above.Hier ilicd^ropenv for Inspection purposes. Signature of Applicant/Agent: ,e A.. Date / B�/�, // SUPPLEMENTI INI'ORJvIATION REQUIRED its V ckazteiN''-3'`�`f' ` {{ Gi Ilei utiHvs•ciStr ti r.^n i°..,(�'/d;eia:ytantf." - If building is associated with a Home Owner's Association,provide letter :�bP ;\CIINCrAfi ^ "I % 1.0O VII\v : - 4r JIQa of approval from I10A. rhsI 3r",ZY,t'IT.:.'"^ i„ry}'Lyt Y"T•-„ 0 ibit :' ,;,c • r �h _1 _ Provide Planning approval to verify if there an 'restrictions. 9'-ea�t}t.�.3 M �FT�d-J pR+Yz y tj4',Sj,V1�DI\6 I \\RtL it. r.`i„3vaaa // y sC14-gwI.N4CSRIjJ sj,m•1• �a r`�u171 \\\1NOn L\;IH:\ILSwi `',jp Provide copy of Manufacturer's Installation Specifications. GO'`Siii�ul s � him �r F �7.i �'F.° }t L t „'Zfa'n:?% . ,.,t-,s Si k(❑ H n<H.OF I s Y ;d'L `' rill* 11. Provide signed copy of Cupertino's Tear-Oil Pohc• c='3'liSik 4 e 47 r s," P•;; \ n t ' r n, % e,r '7t"r i-.,, , 7'a"5ra , O❑ oiTIH.R..7iy� - 1`" '.`d•Ty4-'7';�.•11 i .dictS_ 3"r i yekl•f' 6„f'tit Rife* tex �l L.L.F�'90.^,gy4 L-aaits.ofNY.-,:tieiatve.el ikr...,Lkc W�^n .>.al i� n:".!,'4ef ..2h�Iihig .1 Rtuo'of I pp._2f)//rlor revised 03/16/I I ��i REROOF TEAR-OFF POLICY 1.1DEVELOPMENT DEPARTMENT• BUILDING DIVISION `,cirri ALBERT SALVADOR, P.E.,C.B.O., BUILDING OFFICIAL CUPERTINO 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 p{�yR/E� /Jn //�yy(408)X7//77,-y3�2288• FAX �(4018)777-3333•buildinq(thcupertino.orq PRO{F4 O V S I Owrr_ r Jtorz L , Bich L p APNH �^� [ �,,�� /� rnn/!/�`N� t��AME i w�f G�0 JJJ Pn �.,0 �3-7i3 . 3 `//�?2A'0 '� �W//1t.1�-r . Llw sr 74 ti S pi)k-�f c� �Lrt r-A /�/At ZIPSTATE, b/ G1} g.Sji cJ v FAX Co IRACr R A.MFFIAtA LICENSE NUtIEu7ULICLS^E� BUS.LIC.0 . . .. / 1 2-9 _ CL1N :til'N IE E-�� FAX F,�At K Fly Roowt*c Lnc. Lti'� ��sAtIktabtief 92s yaw. 2.7s z %2 i g u y esti co . k- - ill. nftn-ti 64 9457160 44.54§.-w8y-O/z,f I UNDERSTAND AND AGREE TO THE FOLLOW[NG: I. The re-roof project shall comply with all applicable provisions of the 2010 California Codes. 2. An inspection request can be scheduled up to the day before the inspection date. Please call (408)777- 3228 from 7:30 - 3:30pn1 (Mon-Thurs) or 7:30 - 2:30pm (Friday) to schedule the next day inspection. For Tear-Off and Nailing Inspections, you must also call on the day of the inspection only after that phase of the work is completed. The building inspector will be available within one hour. Progress • and Final Inspections will be given a two hour window. 3. Tear-Off Inspection is required. Any and all dry-rotted wood shall be replaced prior to this inspection. Unless new plywood roof sheathing is proposed throughout, all the nails/fasteners shall be either completely knocked-down or removed prior to this inspection. 4. If plywood is installed, a plywood Nailing Inspection is required. 5. Roofing shall not be applied without first obtaining all prior inspection and written approvals from the building inspector. Any roofing which is applied without first obtaining an approved inspection will require the removal of all new material down to the sheathing so a proper inspection can be performed. 6. Progress Inspection is required when approximately 50% of roof covering is installed. 7. A Final Inspection and approval shall be obtained from the building inspector when the re-roofing is completed. To receive a final sign-off, the following items will be verified: a. Flat roofs shall have a minimum of 1/4" per foot of slope and demonstrate there is no ponding. b. Listings from approved testing agencies for all pre-manufactured products used shall be available on-site to review at the time of the inspection. c. Proper spark arrestor installation, vents painted, gutter/downspouts installed, debris removed. 8. NOTE: If you call for a tear-off or plywood nailing inspection and the work is not complete, you will be charged a re-inspection fee of S 126.00. The re-inspection fee shall be paid before another inspection can be scheduled. By my signing below, I certify each of the following is true: I am the property owner or authorized agent to act on the property owner's behalf. I understand and agree toc: ipl, with the re-roof policy stated above. I also understand that smoke detectors and carbon on.xide detectors a • ui/ i • be installed in accordance with Sections R314 and R315 of the 2010 California Reside tial I.d / r / �� PP/ SignaaueofApplicant/Age°'' 'e j Date: 1 RerooJPolicy_201/.doc revised 02/16/11 Eel ASSOCia' M & C Association Management Services, Inc. August 3, 2012 AUG 13 2012 RE: Re-roof of Portal Plaza Units, Cupertino, CA 95014 • To whom it may concern: The Board of Directors for Portal Plaza Homeowners Association located in Cupertino, CA, has contracted with Frank Fiala Roofing to complete re-roofing during 2012. They • have permission to acquire the necessary permits needed for the HOA project. 0 1 • If you have any questions, please feel free to contact me. • alnal Thank you, . 4'0 • ' Grant Shetron, CMCA, AMS Community Association Manager As Agent for , 41) . . Portal Plaza Homeowners Association gshetron@mccommunities.com A t` • • • • • • 1341 W.Robinhooa Drive,Suite 87.Stockton,CA 95207 lolupwnr 209.644.4900 Fax 209.844.4930 Wet.www.morommundlesmm • 4305 Hacienda Drive,Pleasanton,CA 94588 Telepoonu 925.460.8890 Fes 925.460.8897 • 171 Town Square Road.Suite 2C.Copperopolis.CA 95228 lulephonk 209.785.6700 Fax 209.785.6701 1.209 Woodrow Avenue.Suite C6.1Aoaes;o.CA 95350 Talamenu 209.576.7800 Fax 209.576.2209 • . 538 Alele,Avenue,Reading CA 96002 Telotonne 530.226.5413 Fmk 530.226.5402 • .. •Associs The leader In oommunityaasadatuon management I www.asaoclaonane.com . • f \ I ' a Ji 1 • �`�' rclik,;r• CALIFORNIA TITLE 24, PART 6 REQUIREMENTS II e _ro -Sind �� O poo n� GERTIFICATIONAAND LABELING OF ROOFING'-F DUCTS '. east ROOD q�6 .1,vim. s a.w.0 l4Aa..c 11/..• 132012 Duro-Last roofing membranes meet the requirements set forth in the 2008 Building Energy Efficiency&an rds for certification and labeling of roofing membranes. Below is the text of the requirements (italics)as well as Duro-LailTh- Packaging Label and CRRC Listing for Duro-Last white roofing membrane. SECTION 10-113-CERTIFICATION AND LABELING OF ROOFING PRODUCT REFLECTANCE AND ESIIITAA'CE This section establishes rules for implementing labeling and certification requirements relating to reflectance and en:Mance for roofing products far showing compliance with Sections 141, 142, 143(a)!, !49(b)1 B, 151012, 152(b)114 and/520)2 of Title 24, Califrunia Code of Regulations. Part 6. This section also provides for designation of the Cool Roof Rating Council(CRRC)as the supervisory entity responsible for administering the sole's certification program for roofing products,provided CRRC meets specified criteria. (a)Labeling Requirements. OuRO- Li en'roofrng product installed in cousn'uction /� -" x 0 a o MT6 i fin Wn6F to take compliance credit or meet the WO C -- -- - `AST® Prescriptive requirements for reflectance and -- . . ' "' Roof ing, Inc. eminence under Sections 141, 142, 143(0. ____ __ 149(b)!B, l5/(nl2, 152(b)11/orl52(h)2shall a:a ____ a'F have n clearly visible packaging label that lists ^Coy dlsAN+e+ue u LW m ' the eminance and the initial and 3,rear aged e 's"'°°i""'"""� '•.... "' -' .S' wVavarm d•Ywp Yams e.emwev reflectance tested in accordance with CRRC'-/. •9 'Oryd1M"°" >O • Packngingfor liquid-applied roof coatings shall wee Cawsab ..ara 'a" ... " w^ �^ • ..L.. a.,. state the product meets the Requirements a- • r �1 t}� SP1i1. specified in Section !IS(i) 4. ��'-- Figur a.Packaging Label: See page 2 for larger version. -t 1 rt (b) Certification Requirements. c r -- — _ _ Every roofing product instu!led in consul/Clio?,to ____ger •II ___ — � ' take compliance credit or meet the Prescriptive - = _1+ requirements for reflectance and emiaance under _ _ 7 r ) f4:rlLStc6Yof ett9d' ii4i1AtS-� "_td Sections 141, !4_, 143(0)!, !490)!8, 1510!-, Rated Products Directory:Search Results 'C:S 5.1 l52(b)11/or/52(b)2 shall he certified by CRRC wa �y IW na.%u5Fm b1101>,)1 EST ` .-,�, or another supervis'on•entity approved by the Snowing Swam Results few Carso: Owelatl roecy k Commission pursuant to Section 10-113(c). BIAS. uIOUSt ., lea1E Ma fyr d41'bow RWCB row WR'a7unt40411 Realm I,'c ad baU•WWN AO aNA•'W a amu laws th b t.if rail' 1Id II 115WmeF pc,P9 1 C 424C1 ' ail tc' fA••WbCIWa Sabi React !harmaEmit.lbws Fam.c6tG4 a:m aPons•) Prat Walken !Mashes 5 Jg 057 LCL IaWholes . 05104001 a.>w eme,y kW.IVO"!War. Bion Sega • em 005 Bea 105, A1.15577 Wive Py.iMnvGWtu 04)0 24542001 Figure b.CRRC Listing: See page 2 for larger version. } "duro las�com • 800-248-0280� y s 1 of2 "Duro-Last"and"The World's Best Roof'are registered marks owned by Duro-Last, Inc. LZi t` r •+ r " CODES AND APPROVALS: CITY OF LOS ANGELES /-a -..,..`-°----- V o o 0 ' URO— r 1 White Tan Gray Dark Gray CRYO �"`.'` w xN,C,my w Muter w Prevost w x'..d.0 Palm PrllnuntF Y w F M1Cp a Ned., A AST® F.UrN dm.SM Tlwrma imkta.,. Fl V FO Free Si. Andre Si Mq Rani RWu.t In 0010.0001 GOIDOXIS 001000Dd Eaio.coe Roofing, Inc. - bRPX RGISMS SEM/V Crv.tlrawc•..•towns.b.mid w a< awa.W..7 rclo-UMPS.UCQTISeDD 7 Fplerm m Pau..aa e s amp vu rum/aeroMr md 100810 � ' e ore law v.*a..w.d.,.aevt.. an .mr,..Ipt.� SSTA - - - 4,I' Ifo MEMBRANE FOR ROOFING SYSTEMS AS TO EXTERNAL FIRE EXPOSURE SEE UL DIRECTORY OF PRODUCTS CERTIFIED •City of Los Angeles,California C US FOR CANADA AND UL ROOFING MATERIALS e •Chicago Transit Authority AND SYSTEMS DIRECTORY •Department of Housing Urban Development 810129 .FP° APPROVED •City of New York `vthr,F Cr®G MEMBRANE FOR ROOFING SYSTEMS AS TO UPUFT RESCTENCE Meets California.Me 24,Section 118(i)Requirements. 810129 -���•• ® .'. 1 ICC6. c . d, If® I • 1 • _y.R • Figure a. Packaging Label r B1, c T• COOL ROOF ._ RATING COUNCIL • `.--• inebitia J~\ DireC10 -ofRated Products,----. Rated Products Directory: Search Results Inew search)Iprint friendy r.�;.' ��.,r (last updated Feb 2010 17:38 EST) . • .prri�gL Showing Search Results tor: Company: Duro-Last Roofing Inc. Brand: Duro-Last Model: White select-from products where conpany_name=Duro-Last Roofing Inc.'and brand=turo-Lasr and modekWhite order by company_name asc previous I 1 I next (shoving records 1 - t of 1) 25 Records per Page CRRC Manufacturer _ - - -� _ _ - Ippolar Reflect. Therm Emit.IP Sly Prod.ID Information(sorted+) it Brand Model.Color Product Type Fr'' snit I jf Application 0810.0001 DAI Janni Roofing Inc.j Duro-Last White ight Single-le- 1088 0.68 10.87 10.84.Low Al Janni White.Bright Ply-Thermoplastic (1-800 248-0280) —.—J. Figure h.CRRC Listing. edurGflast`comyt j1' . - . .• . 2 of 2 800-248-0280 • "Duro-Last'and The World's Best Roof'are registered marks owned by Duro-Last,Inc. a . • EZICC-EVALUATION_. y\,-. SERVICE • C • - • Most Nidely Accepted and Trusted ICC-ES Evaluation Report ESR-1660 Reissued February 1, 2012 This report is subject to renewal in two years. www.icc-es.orq I (800)423-6587 I (562)699-0543 A Subsidiary of the International Code Council® DIVISION:070000—THERMAL AND MOISTURE covering is supplied in 64-inch-wide (1.63 m) rolls, which PROTECTION can be fabricated into one-piece membrane sheets up to a Section:07 54 00—Thermoplastic Membrane Roofing maximum size of 3000 square feet(279 m2). REPORT HOLDER: 3.2.2 Insulation: Polyisocyanurate and polystyrene rigid cellular foam plastic thermal insulation specified in Tables DURO-LAST ROOFING, INC. 1 through 4 must comply, respectively, with ASTM C 1289 525 MORLEY DRIVE or ASTM C 578. Foam plastic insulation,where used, must SAGINAW,MICHIGAN 48601 have a flame-spread index of not more than 75 when (800)248-0280 tested in accordance with ASTM E 84 at the maximum www.duro-last.com thickness intended for use. Wood fiberboard must comply with ASTM C 208. See Tables 1 through 4 for insulations EVALUATION SUBJECT: for use with specific roof covering systems. DURO-LAST FIRE-RETARDANT ROOF COVERING 3.2.3 Barrier Layer Coverboard and cover Sheets: SYSTEMS Barrier layer materials, coverboards and cover sheets (which include DensDeck and DensDeck Prime) must be 1.0 EVALUATION SCOPE as specified in Tables 1 and 2. Compliance with the following code: 3.2.4 Fasteners and Stress Plates: Fasteners and stress plates used to attach barrier layer materials, 2006 International Building Code(IBC) insulation boards and the roof covering membrane must be Properties evaluated: corrosion-resistant. Fasteners may be any of Duro-Last insulation and membrane fasteners and plates • Roof covering classification summarized in this section or shown in Tables 3 and 4. • Weather resistance 3.2.4.1 Duro-Last #14 HD Fasteners: Fasteners must • Wind resistance be #14 diameter, corrosion-resistant, threaded fasteners with drill or pinch points and P-3 truss heads. • Impact resistance 2.0 USES 3.2.4.2 Duro-Last #15 Fasteners: Fasteners must be #15 diameter, corrosion-resistant, threaded fasteners with Duro-Last Fire-retardant Roof Covering Systems are drill points and P-3 truss heads. classified, single-ply membrane roofing systems installed over combustible or noncombustible roof decks. 3.2.4.3 Duro-Last Concrete Screws: Screws are corrosion-resistant, dual-threaded fasteners with pinch 3.0 DESCRIPTION points and#3 square drive truss heads. 3.1 General: 3.2.4.4 Duro-Last Concrete Nails: Nails are corrosion- Duro-Last Fire-retardant Roof Covering Systems consist of resistant roofing fasteners having 0.22-inch-diameter the components specified in Tables 1-4, covering one of (5.6 mm) shanks; they are of various lengths and have flat the Duro-Last membranes specified in Section 3.2.1. top pan heads. 3.2 Material: 3.2.4.5 Duro-Last Poly-Plate: A 2-inch-diameter 3.2.1 Duro-Last Membranes: The Duro-Last membrane (51 mm) polycarbonate plate having ten prongs on the is a nominally 40-, 50-, or 60-mil-thick(1.0, 1.2 or 1.5 mm), underside that extend down 0.26 inch (6.6 mm), and a single-ply roof covering membrane having a 35-ounce-per- centrally located 0.245-inch-diameter(6.22 mm)hole. square-yard (1187 g/m2), weft-inserted, polyester-base 3.2.4.6 Duro-Last Insulation Plate: A 3-inch-diameter fiber mat laminated with a thermoplastic film. The (76 mm) polypropylene plate with a recessed, centrally membrane is produced with 3- or 6-inch (76 or 152 mm) located,0.28-inch-diameter(7.1 mm)hole. tabs continuous along the length of the membrane and spaced every 120, 84, 60, 57, 28, 27 or 25 inches 3.2.4.7 Duro-Last 3-inch Metal Plate: A 3-inch-square (3048, 2133, 1524, 1448, 711, 686 or 635 mm) along the (76 mm), 0.24-inch-thick (6.1 mm) galvalume plate with a width for mechanical attachment purposes. The roof centrally located, 0.25-inch-diameter(6.4 mm)hole. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they to be construed <.Q as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LW,express or Implied,as to any finding or other matter in this report,or as to any product covered by the report. Copyright 0 2012 Page 1 of 14 'ESR-1660 3.2.4.8 Duro-Last 2.4-inch Barbed Metal Plate: A 3.3 Impact Resistance: 0.038-inch-thick (0.97 mm), 2.4-inch-diameter (61 mm) The Duro-Last Fire-retardant Roof Covering Systems galvalume plate. described in this report comply with requirements for 3.2.4.9 Duro-Last Cleat Plate: A 23/8-inch-diameter impact resistance in accordance with FM 4470. (60 mm), 0.035-inch-thick (0.89 mm) galvalume ribbed 4.0 INSTALLATION stress plate. The plate is stamped with`cleats' to hold the membrane in place without tearing or puncturing the 4.1 General: membrane. Installation of Duro-Last Fire-retardant Roof Covering Systems must comply with this report and the 3.2.4.10 NTB Magnum Fastener: The fastener is a manufacturer's published installation instructions. The one-piece, glass-reinforced nylon fastener with a 0.75-inch manufacturer's published installation instructions must be (19.1 mm)diameter and a double 0.375-inch(9.1 mm)hex available at the jobsite at all times during installation. recess.The fastener has two internal galvanized wires and Substrates must be free of standing water, gross a plastic plunger. When the plunger is seated, the wires irregularities and sharp projections.The insulation must be extend out from the side ports on the fastener shank and tightly butted and fastened to the substrate using fasteners curl up for assisting in anti-backout. The fastener is and plates noted in Section 3.2.4 and the tables of this available with either a 1-inch-(25.4 mm)or 2-inch-diameter report. (51 mm)head. For systems using mechanically attached Duro-Last 3.2.4.11 Spin Weld Plates: Two-inch-diameter (51 mm) membrane, insulation boards must be attached to the amorphous nylon plates having a 0.23-inch-deep(5.8 mm), substrate using two fasteners for insulation boards that 1-inch-diameter(25.4 mm)recess in the plate center and a have no dimension measuring more than 4 feet 3/4-inch-diameter (19.1 mm), centrally located hole, and (1219 mm), and using four fasteners for insulation boards sixteen spikes on the underside.The Spin Weld Plate is for having any one dimension measuring more than 4 feet use with the NTB Magnum fastener with 1-inch-diameter (1219 mm). (25.4 mm)head. For systems using fully adhered Duro-Last membrane, 3.2.4.12 Liquid Auger Fastener: The fastener is a insulation boards must be attached in accordance with composite nylon and fiberglass fastener/plate system with Table 4 of this report. a modified perforated hollow shank to allow epoxy injected 4.2 Mechanically Attached Membrane: into the shank to seep into the surrounding decking material. For mechanically attached Duro-Last membrane, the membrane must be rolled out on the substrate and 3.2.5 Adhesives: Duro-Last adhesives must not be mechanically attached to the roof deck through the slip thinned. Adhesives used to secure Duro-Last Membrane sheet, insulation, barrier board and/or existing roof are as follows: covering, if present, using fasteners and stress plates as 3.2.5.1 Duro-Last SB I Adhesive: A solvent-based noted in Section 3.2.4 and Table 3.The fasteners must be bonding adhesive for adhering Duro-Last membrane to the placed along and through the fastening tabs. See Table 4 approved substrate. SB I Adhesive is applied to each for fastener and lap details. The two lap types are as surface at 1.5 gal/square/surface (5.68 L). Allow the follows: adhesive on the membrane to produce strings to the touch 4.2.1 Standard: Standard lap consists of fastener/plate (Do not allow to dry) and broom into place after the placement in the 3-inch- or 6-inch-wide (76 mm or adhesive is dry to the touch. 152 mm)preformed tabs. Unless otherwise noted,fastener placement must be through the centerline of the tab width. 3.2.5.2 Duro-Last SB II Adhesive: A solvent-based bonding adhesive for adhering Duro-Last membrane to the 4.2.2 Hybrid: Hybrid lap consists of fastener/plate approved substrate. SB II Adhesive is applied to each placement in the 6-inch-wide (152 mm) preformed tabs. surface at 2.0 gal/square/surface (7.57 L). The membrane Unless otherwise noted, fastener placement must be is applied onto the wet adhesive and broomed into place. through the centerline of the tab width. Prior to the pulling of the membrane for the next lap, Duro-Last Tab Sealer 3.2.5.3 Duro-Last WB I Adhesive: A water-based 4725 must be applied (see Section 3.2.5.5) over the tab bonding adhesive for adhering Duro-Last membrane to the membrane and to the underside of the overlying approved substrate. WB I Adhesive is applied to each membrane (two-sided application) at an approximate rate surface at 0.5 gal/square/surface(1.9 L).The membrane is of 30 ft2/gal/side. Care must be used to avoid wrinkles and applied and broomed into place after the adhesive is dry to air pockets. the touch. 4.3 Fully Adhered Membrane: 3.2.5.4 Duro-Last WB II Adhesive: A water-based For fully adhered Duro-Last membrane, the prefabricated bonding adhesive for adhering Duro-Last membrane to the roof section is positioned over the area to be covered.The approved substrate. WB II Adhesive is applied to the roof section is folded back onto itself to expose half of the substrate only at 0.7 gal/square/surface (2.65 L). The roof area to be covered by that section. Adhesive is membrane is applied onto the wet adhesive and broomed applied in front of the fold along its length in accordance into place. with Section 3.2.5 of this report. Care must be taken not to 3.2.5.5 Duro-Last Tab Sealer 4725: A solvent-based apply more of the adhesive than can be covered prior to contact-bonding agent for use in the Hybrid lap fastening the adhesive setting up. The top layer of membrane is method for the mechanically attached membranes. See lifted and, starting at the fold, a stiff squeegee or broom is Section 4.2.2. used to push the membrane into the adhesive. Care must be used to avoid wrinkles and air pockets. As each new 3.2.6 Perimeter Flashing: Duro-Last fascia systems, roof section is added, the adjacent sheets are overlapped gravel stop edging and drip edge edging are fabricated a minimum of 3 to 6 inches(76 mm or 152 mm),with care from rigid exterior vinyl and metal two-piece composite and taken to avoid contamination of the membrane where snap-on metal. seams will be welded together. ESR-1660 I Most Widely Accepted and Trusted Page 3 of 14 4.4 Seam Welding: 5.2 The roof covering system must be installed by After the membrane is fastened or bonded,sheets must be applicators authorized and trained by Duro-Last, Inc. welded (heat-fused) together using hot air supplied by 5.3 For applications where foam plastic insulation is either a handheld or self-propelled welder. Each installed directly over a steel deck, an ICC-ES membrane sheet overlaps the adjacent sheet 3 to 6 inches evaluation report recognizing the specific foam plastic (76 mm to152 mm). Field welds must be a minimum of insulation for direct-to-steel-deck applications must be 11/2 inches (38 mm) wide. The welded seam must be required. checked for continuity and integrity. 4.5 Vents, Parapets,Protrusions and Edge Details: 5.4 Foam plastic insulation must be separated from the interior of the building by an approved thermal barrier All vents, parapets, protrusions and edge details must be in accordance with IBC Section 2603.4.1.5,except for flashed in accordance with Duro-Last's published installations in accordance with Section 5.3 and installation instructions. Footnote 7 to Table 1 and Footnote 8 to Table 2. 4.6 Fire Classification: 5.5 Foam plastic insulation, where used, must bear the The mechanically fastened and adhered PVC single-ply label of an approved agency indicating that the foam membrane roofing systems, when installed in accordance plastic has a flame-spread index of not more than 75 with this report, are Class A, B or C roof covering systems when tested at the maximum thickness intended for in accordance with UL 790 (ASTM E 108), as noted in use in accordance with ASTM E 84, subject to the Table 1 and 2. approval of the code official. 4.7 Wind Resistance: 5.6 The allowable wind uplift loads in Tables 3 and 4 are When the Duro-Last membranes specified in Section 3.2.1 for the roof covering system only. The deck and are installed in accordance with this report, the allowable framing to which the system is attached must be uplift capacities for the PVC single-ply membrane roofing designed for the applicable components and cladding systems are as noted in Tables 3 and 4. In accordance wind loads in accordance with the IBC. with IBC Section 1504.5, metal edge securement systems 5.7 Wind uplift pressure on any roof area, including edge for low-slope roofs (roof slope less than 2:12) must be and corner zones, must not exceed the allowable designed in accordance with ANSI/SPRI ES-1. The wind uplift pressure for the system installed in that Duro-Last edge flashing systems, components and details particular roof area. specified in Sections 3.2.6 and 4.5 provide edge securement for mechanically attached membranes. When 5.8 Duro-Last membranes are manufactured in Saginaw, tested in accordance with Test RE-1 of ANSI/SPRI ES-1, Michigan;Grants Pass, Oregon;Jackson, Mississippi; the systems and components provide the following and Sigourney, Iowa, under a quality control program maximum load resistances: 666 plf (992 kg/m) for the with inspections by Underwriters Laboratories Inc. Duro-Last 4-inch Facia System (Edge Detail 3040); 895 plf (AA-668). (1333 kg/m) for the Duro-Last 4-inch Drip Edge (Edge 6.0 EVIDENCE SUBMITTED Detail 3070); 900 plf(1341 kg/m) for the Duro-Last 4-inch Data in accordance with the ICC-ES Acceptance Criteria Gravel Stop (Edge Detail 3100);and 455 plf(678 kg/m)for for Membrane Roof-covering Systems (AC75), dated April the 2-piece Duro-Guard Metal Compression System (Edge 2007. Detail 3110). 5.0 CONDITIONS OF USE 7.0 IDENTIFICATION The Duro-Last Fire-retardant Roof Covering System The Duio-Last Fire-retardant Roof Covering Systems components (membrane, fasteners and adhesives) described in this report comply with, or are suitable described in this report are identified with a label indicating alternates to that specified in,those codes listed in Section the manufacturer's name (Duro-Last Roofing, Inc.), the 1.0 of this report,subject to the following conditions: product type, the name of the inspection agency 5.1 Installation must comply with this report, the (Underwriters Laboratories Inc.) and the evaluation report manufacturer's published installation instructions and number(ESR-1660). the applicable code. In the event of a conflict between the manufacturer's published installation instructions and this report,this report governs. ESR-1660 I Most Widely Accepted and Trusted Page 4 of 14 TABLE 1—MECHANICALLY ATTACHED MEMBRANE ROOFING CLASSIFICATION° SYSTEM CLASS' SUBSTRATE' MAX. EXISTING BARRIER,INSULATION AND/OR COVERBOARD NO. SLOPE ROOF ar Coverboard°or Barrier Insulation Coversheet 1 A Combustible 1/4:12 Class A,B or Min.'/cinch Type X (Optional)1-inch min. None C roof gypsum or min.1/4- to 4-inch max. inch DensDeck or thickness, DensDeck Prime Atlas ACFoam II° 2 B Combustible 1:12 Class B One layer ASTM D None None smooth 226,type II,or D 4601, surface BUR type II felt,Atlas FR10, '/cinch-thick. GreenGuard P14,PB4 or PBS,'lrinch-thick. Carpenter Foamfold, min.'/4-inch DensDeck or DensDeck Prime or 3-mil polyethylene film 3 B Combustible 314:12 None Two layers Atlas FR10 None None 4 A Combustible 3:12 None Min.'lrinch Type X (Optional)1-inch min. None gypsum or min.1/4- to 4-inch max.,Atlas inch DensDeck or ACFoam II DensDeck 5 C Combustible 1:12 None One layer Atlas FR10 (Optional)1-inch min. None or min.'/4-inch to 4-inch max. DensDeck or thickness,Atlas DensDeck Prime ACFoam II or Rmax Multi-Max-3 6 A Combustible '14:12 Class A,B or Min.'lrinch Type X (Optional)Any Min.'14-inch DensDeck or C roof gypsum or min.1/4- thickness UL DensDeck Prime inch DensDeck or Classified DensDeck Prime polystyrene° 7 Per Combustible 2:12 Class A,B or None None None existing C roof roof (classification retained) 8 A Combustible 3:12 None Min.'/cinch Type X (Optional)Any Min.'/4-inch DensDeck or gypsum'or min.1/4- thickness UL DensDeck Prime inch DensDeck or Classified DensDeck Prime polystyrene. 9 A Noncombustible 3:12 Class A None None None gravel surface roof 10 A Noncombustible 3:12 None None (Optional)1-inch min. None to 4-inch max. thickness,Atlas ACFoam II 11 A Noncombustible 3:12 None None (Optional)Any Min.'/4-inch DensDeck or thickness UL DensDeck Prime or Atlas Classified FR10 polystyrene. 12 Per Combustible 2:12 Class A,B or None None None existing C roof roof (classification retained) 13 A Noncombustible '/4:12 Class A,B or None (Optional)Any Min.'/4-inch DensDeck or C roof thickness UL DensDeck Prime or Atlas Classified FR10 polystyrene° 14 B Combustible No limit None UL Classified Class C None None mineral-surfaced roll roofing followed by two layers Atlas FR10 ESR-1660 I Most Widely Accepted and Trusted Page 5 of 14 • TABLE 1— MECHANICALLY ATTACHED MEMBRANE ROOFING CLASSIFICATION°(Continued) SYSTEM CLASS' SUBSTRATE''' MAX. EXISTING BARRIER,INSULATION AND/OR COVERBOARD NO. SLOPE ROOFCoverboard°or Baffler Insulation.,;qr Coversheet 15 Per Combustible 2:12 Class A,B or None 1/2-inch-thick. None existing C BUR, Plymouth Ultra-Fold roof smooth TPM° surface,cap sheet or gravel surfaced with gravel at 400 lbs/sq. (classification retained) 16 A Noncombustible '/4:12 Class A,B or None (Optional)1-inch min. None C roof to 4-inch max. thickness,Atlas ACFoam II° 17 B Combustible 2:12 None UL Classified Class C None None mineral-surfaced roll roofing followed by two layers Atlas FR10 18 A Min.3/4-inch '/4:12 Class A roof None None None plywood 19 Per Noncombustible 1/2:12 Class A,B or None Min. 1-inch UL Leggett 8 Platt Nova existing C roof Classified Rollout roof (classification polyisocyanurate° retained) 20 A Combustible '/4:12 None Four layers Atlas (Optional)1-inch min. None FR10 to 4-inch max. thickness,Atlas ACFoam II or Rmax Multi-Max-3 21 A Noncombustible No limit None None None None 22 B Noncombustible 3:12 None None 1-inch min.to 4-inch None max.thickness, Rmax Multi-Max-3 23 A Combustible 1/4:12 Class A,B or One layer ASTM D None None C gravel 226,type II,or D 4601, surface roof type II felt,Atlas FR10, with gravel at 1/2-inch-thick. 400 lbs/sq GreenGuard P14,PB4 or PB6°,or min.1/4- inch DensDeck or DensDeck Prime 24 A Combustible '/4:12 Class A,B or Two layers Atlas FR10 None None C smooth surfaced BUR 25 A Combustible 2:12 None UL Classified Class C None None mineral-surfaced roll roofing followed by four layers Atlas FR10 26 A Combustible 1:12 Class A None 1/2-inch-thick None gravel Carpenter Insulation surface roof Foamfold° with gravel at 400 lbs/sq 27 A Combustible No limit Class A,B or Min.'/finch Type X None None C roof gypsum or min. 1/4- inch DensDeck or DensDeck Prime 28 A Combustible No limit None None My thickness,UL Min.'/-inch Type X Classified gypsum or min.'/4-inch polystyrene or DensDeck or DensDeck polyisocyanurate Prime 29 B Noncombustible No limit None None 1-inch min.to 4-inch One layer Atlas FR50 max.thickness,Atlas ACFoam II ESR-1660 I Most Widely Accepted and Trusted Page 6 of 14 TABLE 1—MECHANICALLY ATTACHED MEMBRANE ROOFING CLASSIFICATION°(Continued) SYSTEM CLASS' SUBSTRATE'" MAX. EXISTING BARRIER,INSULATION AND/OR COVERBOARD NO. SLOPE ROOF Barrier • Insulation Coverboard°or Coversheet 30 A Noncombustible 1:12 None None 1-inch-min.to 4-inch None max.thickness,Atlas ACFoam II 31 A Noncombustible 3:12 Insulated or One layer Atlas FR10 None None non-insulated or Elk Versashield 15 ballasted or min.'/4-inch single ply DensDeck or membrane DensDeck Prime with or without ballast removed 32 B Combustible 1:12 None One layer Atlas FR10 2-inch min.to 4-inch None or min.'/4-inch max.thickness,Atlas DensDeck or ACFoam II,Firestone DensDeck Prime ISO 95+GW or Rmax Multi-Max FA-3 33 B Combustible 1:12 None One layer Atlas FR50 None None 34 A Noncombustible No limit None None Any thickness,UL One layer,Atlas FR10 or Classified min.1/4-inch DensDeck or polystyrene DensDeck Prime 35 A Noncombustible 21/2:12 None None 1-inch min.to 4-inch None max.thickness, Rmax Multi-Max-3 36 A Combustible 2:12 Class A,B or (If gravel is removed) '/-inch-thick None C BUR, Min.'/-inch Type X Plymouth Ultra-Fold smooth gypsum or min.1/4- TPM° surface,cap inch DensDeck or sheet or DensDeck Prime gravel- surfaced (gravel may be removed) 37 A Combustible 2:12 Class A None '/-inch-thick. None smooth or GreenGuard PB6, gravel- PB6W,PG38,PG39 surfaced or Duro-Fold° BUR(gravel maintained at 400 lbs/sq.) 38 B Combustible 2:12 None Min.two layers Elk None None Versashield Undedayment 39 B Combustible 2:12 None Min.one layer Elk None None Versashield Undedayment 40 A Combustible 1'/2:12 None Min.'/,-inch Type X (Optional)1-Inch min. None gypsum or min.1/4- to 4-inch max. inch DensDeck or thickness,Atlas DensDeck Prime ACFoam II or Rmax Multi-Max-3 41 B Combustible 11/2:12 None One layer Elk None None Versashield FB-25 42 A Noncombustible 3:12 None None Any thickness,UL Min.1'/2-inch Atlas Classified ACFoam III polystyrene 43 A Noncombustible 3:12 None None 1-inch min.to 4-inch None max.thickness,Atlas ACFoam II 44 A Noncombustible No limit None None Any thickness,UL One layer Atlas FR10 or Classified min.'14inch DensDeck or polystyrene DensDeck Prime 45 A Combustible No limit None Four layers Atlas None None FR10 ESR-1660 I Most Widely Accepted and Trusted Page 7 of 14 TABLE 1—MECHANICALLY ATTACHED MEMBRANE ROOFING CLASSIFICATION'(Continued) SYSTEM CLASS' SUBSTRATE;' MAX. EXISTING BARRIER,INSULATION AND/OR COVERBOARD NO. SLOPE ROOF Coverboard'or Barrier Insulation'4;y' Coversheet 46 A Noncombustible 1:12 None None 1/2-inch-thick None Carpenter Insulation Foamfold 47 A Combustible 3:12 None Min. 1/4-inch DensDeck None None 48 A Noncombustible 2:12 None None 1-inch min.to 4-inch None max.thickness, Hunter H-Shield 49 A Noncombustible 2:12 None None 1/2-inch-thick None Plymouth Ultra-Fold TPM 50 A Combustible 2:12 None Min.1/2-inch Type X 'h-inch-thick None gypsum or min.'L- Plymouth Ultra-Fold inch DensDeck or TPM DensDeck Prime 51 A Noncombustible 1:12 None None 1-inch min.to 4-inch None max.thickness, Firestone ISO 95+GL 54 A Combustible 74:12 None Three layers Elk Any thickness,UL None Versashield FB-1S Classified polyisocyanurate 55 A Combustible 3/4:12 None One or more layers 1-inch min.to 44nch None Elk Versashield FB-1 S max.thickness, Rmax Ultramax 56 A Combustible '/4:12 None Two layers Elk Any thickness,UL None Versashield FB-1S Classified polyisocyanurate 57 A Combustible 3:12 None None (Optional)Any Min.'/4-inch DensDeck thickness,UL Classified polyisocyanurate 58 A Noncombustible 1/2:12 None None Min. 1-inch UL Leggett 8 Platt Nova Classified Rollout polyisocyanurate For SI:1 inch=25.4 mm, 1 pcf=16.018 kg/m3,1 sq.ft.=0.093 m2, 1 gal/100 sq.ft.=0.41 Um2. 'New insulated or noninsulated roof systems may be installed over existing noninsulated roof systems provided the resulting classification is taken as the lower of the new or existing roof classification. 'Noncombustible deck system classifications are permitted for use over combustible decks when minimum'/4-inch DensDeck or DensOeck Prime is applied directly over the combustible deck or directly over the insulation with all joints in the barrier of coverboard staggered 6 Inches from plywood joints. 'Noncombustible substrates include structural concrete,lightweight concrete,gypsum and steel. 4All foam plastic insulation must be UL Classified foam plastic,and must be limited to the maximum thickness in accordance with Section 5.5 of this report or the maximum thickness in accordance with this table,whichever is less. sUnless otherwise noted,polyisocyanurate insulation must be Type II in accordance with ASTM C1289 and expanded polystyrene must comply with ASTM C 578. °Unless otherwise noted,the top insulation layer(insulation or coverboard)must be presecured with four fasteners per board for a board having any dimension greater than 4 feet and two fasteners per board for a board having a maximum dimension of 4 feet. 'Foam plastic insulation is permitted to be installed over a steel deck without a thermal barrier when an ICC-ES evaluation report on the specific foam plastic insulation allowing direct to metal deck applications is provided for approval of the code official.See Sections 5.3 and 5.4 of this report for conditions of use. °Unless otherwise specified,the baffler,insulation,coverboard,coversheet,membrane adhesive and membrane must be UL Classified for roofing system application. °Roof coverings containing foam plastic insulation must not be installed over existing roof coverings containing foam plastic insulation. ESR-1660 I Most Widely Accepted and Trusted Page 8 of 14 TABLE 2—FULLY ADHERED MEMBRANE ROOFING CLASSIFICATION° SYSTEM CLASS' SUBSTRATE" MAX. EXISTING BARRIER,INSULATION AND/OR COVERBOARD MEMBRANE NO. SLOPE ROOF ° ADHESIVE Barrier Insulation ;4' Coverboard or Coversheet 1 A Noncombustible 2'/2:12 None None Any thickness,UL Min.1/4-inch DensDeck or WB I Classified polystyrene DensDeck Prime 1-inch min.to 4-inch 2 A Noncombustible 2:12 None None max.thickness,Atlas AC None WB I Foam II Any thickness,UL 3 A Noncombustible 21/2:12 None None Classified Min.'l,-inch DensDeck WB I polyisocyanurate in hot Prime in hot asphalt asphalt For SI: 1 inch=25.4 mm, 1 pcf=16.018 kg/m',1 sq.ft.=0.093 m2, 1 ga11100 sq.ft.=0.41 Um2. 'New insulated or noninsulated roof systems may be installed over existing noninsulated roof systems provided the resulting classification Is taken as the lower of the new and existing roof classification. 2Noncombustible deck system classifications are permitted for use over combustible decks when minimum '/4-Inch DensDeck or DensDeck Prime is applied directly over the combustible deck or directly over the insulation with all joints in the barrier of coverboard staggered 6 Inches from plywood joints. 'Noncombustible substrates Include structural concrete,lightweight concrete,gypsum and steel. °All foam plastic Insulation must be UL Classified foam plastic,and must be limited to the maximum thickness in accordance with Section 5.5 of this report or the maximum thickness in accordance with this table,whichever is less. °Unless otherwise noted, polyisocyanurate insulation must be Type II in accordance with ASTM C 1289 and polystyrene must comply with ASTM C 578. °Unless otherwise noted,the top insulation layer(insulation or coverboard)must be mechanically fastened. 'Foam plastic insulation is permitted to be installed over a steel deck without a thermal barrier when an ICC-ES evaluation report on the specific foam plastic insulation allowing direct-to-metal-deck applications is provided for approval of the code official.See Sections 5.3 and 5.4 of this report for conditions of use. °Unless otherwise specified, the baffler, insulation, coverboard, coversheet, membrane adhesive and membrane must be UL Classified for roofing system application. TABLE 3—ATTACHMENT METHODS FOR MECHANICALLY ATTACHED MEMBRANE' SYSTEM DECK INSULATION"3 LAP TYPE FASTENER' SPACING(inches) ALLOWABLE NO. UPLIFT Tab Tab Fastener CAPACITY Width Spacing Spacing (Ibf/N2) Duro-Last#14 HD MIA Standard Fastener and Poly 3 57 18 30 Plates Duro-Last#14 HD M1B Min.'/4-inch Standard Fastener and Poly 3 60 12 30 plywood or min. None Plates 2-inch wood Duro-Last#14 HD M1C plank Standard Fastener and Poly 3 27 18 45 Plates Duro-Last#14 HD MID Standard Fastener and Poly 3 57 12 45 Plates (Optional) Duro-Last#14 HD M2A One or more Hybrid Fastener and Poly 3 60 6 45 layers,foam plastic insulation Plates Min.12/32-inch 6 plywood or min. Duro-Last#15 HD (Fastener line M2B 2-inch wood Standard Fastener and 2.4-inch 6 57 located 2.7- 52 plank Barbed Seam Plates inch from lab None edge) Duro-Last#14 HD M2C Hybrid Fastener and 3-inch 6 57 6 52 Metal Plates Nom.1 x 6-inch One or more Duro-Last#15 M3 T8G board layers,foam Hybrid Fasteners with ITW 6 25 6 98 decking plastic insulation Buildex 23l3-inch Eyehook Plates • ESR-1660 I Most Widely Accepted and Trusted • Page 9 of 14 TABLE 3—ATTACHMENT METHODS FOR MECHANICALLY ATTACHED MEMBRANE1 (Continued) SYSTEM DECK INSULATION•-' LAP TYPE FASTENER' SPACING(inches) ALLOWABLE UPLIFT I Tab Tab Width Spacing Fastener Spacing CAPACITY(Ibflft2) I Duro-Last#14 HD M4A Standard Fastener and Poly 3 57 18 30 I Plates I Duro-Last#14 HD M4B Standard Fastener and Poly 3 60 12 30 I Min.22 ga. None Plates Grade 33 steel Duro-Last#14 HD M4C Standard Fastener and Poly 3 27 18 45 I Plates I Duro-Last#14 HD M4D Standard Fastener and Poly 3 57 12 . 45 I Plates I Duro-Last#14 HO M5A None Standard Fastener and Poly 3 60 18 30 I Plates I 1.5-inch min.to 4- Tru-Fast EHD 12 (Fastener line M5B inch max. Standard fasteners and Duro- 6 120 located 1.75- 38 I thickness,Johns Last Cleat Plates inch from tab Manville"ENRGY edge) 3,"Firestone"ISO- I 95+GL,"Rmax 6 "Multi-max FA-3," Tru-Fast EHD (Fastener line M5C Atlas Roofing"AC Standard fasteners and Duro- 6 120 located 1.75- 45 I Foam II"or"AC Last Cleat Plates inch from tab Foam III" edge) I Duro-Last#14 HD M50 Standard Fastener and Poly 3 60 12 45 I None Plates I Duro-Last#14 HD M5E Standard Fastener and Poly 3 84 6 45 I Plates 1.5-inch min.to 4- inch max. thickness,Johns Manville"ENRGY Tru-Fast EHD M5F 3,"Firestone'ISO- Hybrid fasteners and Duro- 6 120 12 45 95+GL,"Rmax y Last Cleat Plates `Multi-max FA-3, Min.22 ga. Atlas Roofing"AC Grade 80 steel Foam 11"or"AC Foam 1W I Duro-Last#14 HD M5G Standard Fastener and Poly 3 120 6 52 I Plates I . Duro-Last#14 HD M5H Standard Fastener and Poly 3 28 18 52 I None Plates I Duro-Last#15 M5J Hybrid Fastener and 3-inch 6 57 6 52 I Metal Plates I Duro-Last#15 M5K Hybrid Fastener and 3-inch 6 84 6 52 I Metal Plates 1.5-inch min.to 4- inch max. thickness,Johns Manville"ENRGY Tru-Fast EHD MSL 3,"Firestone"ISO- Hybrid fasteners and Duro- 6 84 12 52 95+GL,"Rmax Last Cleat Plates "Multi-max FA-3," Atlas Roofing"AC Foam 11"or"AC Foam III" I Duro-Last#15 M5M None Standard Fastener and 2.4-inch 3 84 6 60 I Barbed Seam Plates ESR-1660 I Most Widely Accepted and Trusted Page 10 of 14 • TABLE 3—ATTACHMENT METHODS FOR MECHANICALLY ATTACHED MEMBRANE'(Continued) SYSTEM DECK INSULATION1R3 LAP TYPE FASTENER' SPACING(inches) ALLOWABLE NO. UPLIFT Tab Tab Fastener CAPACITY Width Spacing Spacing (Ibf/ftp) 1.5-inch min.to 4- inch max. thickness,Johns Manville'ENRGY Tru-Fast EHD MSN 3,"Firestone"ISO- Hybrid fasteners and Duro- 6 57 12 68 95+GL,"Rmax Last Cleat Plates "Multi-max FA-3," Atlas Roofing"AC Foam 1r or'AC Foam or 1.5-inch-thick Duro-Last#15 END MSP polyisocyanurate Hybrid Fasteners and Batten 3 60 6 68 Bar Duro-Last#14 HD M5Q Standard Fastener and Poly 3 28 12 75 None Plates Duro-Last#15 M5R Hybrid Fastener and 3-inch 6 120 6 82 Metal Plates 1.5-inch min.to 4- inch max. thickness,Johns Min.22 ga. Manville"ENRGY Grade 80 stee 3,"Firestone"ISO- Tru-Fast EHD M5S (Continued) 95+GL,"Rmax Hybrid fasteners and Duro- 6 84 6 98 "Multi-max FA-3," Last Cleat Plates Atlas Roofing"AC Foam II"or"AC Foam III" Duro-Last#15 M5T None Hybrid Fastener and 3-inch 6 57 6 105 Metal Plates 1.5-inch min.to fl- inch max. thickness,Johns Manville"ENRGY 3",Firestone"ISO- Tru-Fast EHD MSU 95+GL,"Rmax Hybrid fasteners and Duro- 6 57 6 135 "Multi-max FA-3; Last Cleat Plates Atlas Roofing"AC Foam II"or'AC Foam III" One or more Duro-Last#15 M5V layers,foam HybridFasteners with MN6 25 6 142 plastic insulation Buildex 73/E-inch Eyehook Plates Duro-Last Concrete M6A Standard Screw or Nail and 3 57 18 30 Poly Plates Duro-Last Concrete M6B Standard Screw or Nail and 3 60 12 30 Poly Plates Duro-Last Concrete M6C Standard Screw or Nail and 3 27 18 45 Poly Plates Duro-Last Concrete M6D Concrete None Standard Screw or Nail and 3 57 12 45 Poly Plates Duro-Last Concrete M6E Standard Screw or Nail and 3 84 6 45 Poly Plates Duro-Last Concrete M6F Hybrid Screw or Nail and 3- 6 57 12 52 inch Metal Plates Duro-Last Concrete M6G Hybrid Screw or Nail and 3- 6 84 6 52 inch Metal Plates ESR-1660 I Most Widely Accepted and Trusted Page 11 of 14 TABLE 3—ATTACHMENT METHODS FOR MECHANICALLY ATTACHED MEMBRANE'(Continued) SYSTEM DECK INSULATION'•''' LAP TYPE FASTENER' SPACING(Inches) ALLOWABLE NO. UPLIFT Tab Tab Fastener CAPACITY Width Spacing Spacing (Ibflft') Duro-Last Concrete M6H Standard Screw or Nail and 2.4- 3 84 6 60 inch Barbed Seam Plates None Duro-Last Concrete M6J Hybrid Screw or Nail and 3- 6 120 6 82 Concrete inch Metal Plates (Continued) Duro-Last Concrete M6K Hybrid Screw or Nail and 3- 6 57 6 105 inch Metal Plates One or more Duro-Last Concrete M6L layers,foam Hybrid Screw o Nail and 6 25 6 142 plastic insulation ITW 2-/a-inch Eyehook Plates Duro-Last NTB M7A Standard Magnum and Spin 3 57 9 30 None Weld Plates Duro-Last NTB M7B Standard Magnum and Spin 3 60 6 38 Weld Plates 'rectum or Duro-Last NIB M7C existing gypsum Standard Magnum and Spin 3 57 6 45 Weld Plates Duro-Last NTB M7D None Standard Magnum and Spin 3 60 4 45 Weld Plates M7E Standard Duro-Last Liquid 6 57 6 45 Fastener M7F None Hybrid Duro-Last Liquid 6 57 6 60 Fastener 31-Inch-wide, Duro-Last Liquid min. 1.5-inch min.to 4- Auger Fastener with inch max. M8A 2'/rinch-thick thickness,Johns Hybrid Ashland Pliogrip 6 57 12 38 Tectum fastened Manville'ENRGY 7779LI220 Structural to steel supports3,Firestone'ISO- Adhesive spaced 5 ft.o.c. 95+GL,"Rmax with Tru-Fast Duro-Last Liquid "Multi-max FA-3," Auger Fastener with puriin fasteners M8B and Atlas Roofing"AC Hybrid Ashland Pliogrip 6 57 6 68 2-inch Metal Foam II"or"AC 7779L1220 Structural Plates Foam III" Adhesive M9A Existing Standard Duro-Last Liquid 6 57 6 45 lightweight None Fastener M9B concrete Hybrid Duro-Last Liquid 6 57 6 60 Fastener For SI: 1 inch=25.4 mm,1 Ibf/ft'=47.88 Pa, 1 lbf=4.4 N. 'Insulations,fasteners,adhesives and membranes must be FM-approved. 'All foam plastic insulation must be limited to the maximum thickness In accordance with Section 5.5 of this report or the maximum thickness in accordance with this table,whichever is less. 'All insulation must be preliminarily attached to the deck in accordance with FM requirements. ESR-1660 I Most Widely Accepted and Trusted Page 12 of.14 - TABLE 4—ATTACHMENT METHODS FOR FULLY ADHERED MEMBRANE' SYSTEM DECK Insulation'' Coverboard' ADHESIVE' ALLOWABLE NO. ---- - ---- - — UPLIFT Type Fastener' Rate Type Fastener' Rate CAPACITY (lbf/ft') One or more Duro-Last#14 layers min.1.S HD Fastener and 2 ft'/ A1A inch thick None N/A N/A SB I 45 ACFoam II or 3-inch Metal fastener ACFoam III Plates One or more Duro-Last#14 layers min.1.5- HD Fastener and 2 ft'/ A1B inch thick 3-inch Metal fastener None N/A N/A SB II 38 ACFoam II or Plates ACFoam III Min.3/4-inch One or more plywood or min. Duro-Last#14 2-inch wood layers min. 1.S HD Fastener and 4 ft'/ A1C inch thick None N/A N/A SB I 45 plank or min.22 3-inch Metal fastener ga.,Grade 33 ACFoam II or Plates steel ACFoam III One or more Duro-Last#14 layers min, 1.5- HD Fastener and 4 ftp/ A1D inch thick None N/A N/A SB II 38 ACFoam II or 3-inch Metal fastener ACFoam III Plates One or more Duro-Last#14 A1E layers min.1.5- HD Fastener and 4ft2/ None NIA N/A WB I 45 inch thick 3-inch Metal fastener ACFoam III Plates One or more layers min.1.0- Duro-Last#14 A1F inch thick HD Fastener and 2 ft'/ None N/A N/A WB II 38 ACFoam II or 3-inch Metal fastener ACFoam Plates Recover MM.'/4- Duro-Last One or more inch-thick #14 HD layers min.1.S DensOeck Fastener 2 ftp/ A2A Min.'/4-inch inch thick Loose laid N/A or and 3-inch fastener SB I 45 plywood or min. ACFoam II or ACFoam III DensDeck Metal 2-inch wood Prime Plates plank or min.22 Min.'/4- Duro-Last ga.,Grade 33 One or more inch-thick #14 HD steel layers min.1.S DensDeck Fastener 2.67 ft2/ A2B inch thick Loose laid N/A or and 3-Inch fastener SB I 30 ACFoam II or DensDeck Metal ACFoam III Prime Plates One or more Min.'h- Duro-Last layers min.1.5- inch-thick #14 HD A2C inch thick Loose laid N/A DensDeck Fastener 3.2 19 SB I 30 Min.3/4-inch ACFoam II or or and 3-inch fastener plywood or min. ACFoam III DensDeck Metal 2-inch wood Prime Plates plank or min.22 MM.3/r Duro-Last ga.,Grade 33 One or more inch-thick #14 HD steel layers min. 1.S DensDeck Fastener 4 ft2/ A2D inch thick Loose laid N/A or and 3-inch fastener SB I 30 ACFoam II or DensDeck Metal ACFoam III Prime Plates Min.2-inch- thick AtlasRofing Insta-Stick, 3 "ACFoam ll,° Duro-Last#14 Olybond ribbons Min 22ga., Hunter Panels HD Fastener and 4 ft'/ Minimum 500, spaced A3A Grade 33 Steel 'H-Shield," 3-inch Metal fastener /4-inch TITESET or 12 SB II 38 Johns Manville Plates Securock Weather- inches "ENRGY-3"or TdSt�P e- o.c. Firestone 'ISO 95+GL" ESR-1660 I Most Widely Accepted and Trusted Page 13 of 14 • TABLE 4—ATTACHMENT METHODS FOR FULLY ADHERED MEMBRANE'(Continued) SYSTEM DECK Insulation'•' Coverboard' ADHESIVE' ALLOWABLE NO. UPLIFT Type Fastener' Rate Type Fastener' Rate CAPACITY (Ibfflt') Min.2-inch- thick Atlas Roofing Insta-Stick, 3/4-inch "ACFoam Duro-Last#14 Olybond ribbons 11;Hunter HD Fastener and 2.67,/ Minimum 500, spaced A3B • Panels"H- 3-inch Metal fastener /^ TITESET or 12 SB II 45 Shield,"Johns plates Securock Weather- inches Manville lite One- "ENRGY-3"or Step o.c. Firestone Min 22ga., 150 95+GL" Grade 33 Steel Min.'/rinch Duro-Last (Continued) Securock or #14 HD Minimum A3C min. 1-inch Loose laid N/A '/4-inch Fastener 2.67 ft/ SB II 38 BASF or Securock and 3-inch fastener Huntsman 1 pcf Metal EPS board Plates Min. '/rinch Duro-Last Securock or #14 HD Minimum A3D Min. 1-inch Loose laid N/A 5/6-inch Fastener 4 ftft2/ SB II 45 BASF or Securock and 3-inch fastener Huntsman 1 pcf Metal EPS board Plates One or more Duro-Last layers min.1.5- Concrete Screw 2 ft2/ A4A inch-thick None N/A N/A SB I 45 ACFoam II or or Nail and 3-inch fastener ACFoam III Metal Plates One or more Duro-Last layers min.15- Concrete Screw 2 ft2/ A4B inch-thick None N/A N/A SB II 38 ACFoam II or or Nail and 3-inch fastener ACFoam III Metal Plates One or more Duro-Last layers min.1.5- Concrete Screw 4 f12/ A4C inch-thick or Nail and 3-inch fastener None N/A N/A SBI 45 ACFoam II or Metal Plates ACFoam Ill One or more Duro-Last layers min.1.5- Concrete Screw 4 ft2/ A4D inch-thick None N/A N/A SB II 38 ACFoam II or or Nail and 3-inch fastener ACFoam III Metal Plates One or more Duro-Last A4E Concrete layers min.1.5- Concrete Screw 4 ftp I None N/A N/A WB I 45 inch-thick or Nail and 3-inch fastener ACFoam III Metal Plates One or more layers min. 1.0- Duro-Last A4F inch-thick Concrete Screw 2 ft2/ None N/A N/A WB 11 38 ACFoam II or or Nail and 3-inch fastener ACFoam Metal Plates . Recover Min.'/4- Duro-Last One or more inch-thick Concrete layers min.1.5- Screw or A4G inch-thick Loose laid N/A DensDeck Nail and 2ft- / SBI 45 ACFoam II or or 3-inch fastener ACFoam III DensDeck Metal Prime Plates Duro-Last One or more Min. /4- Concrete inch-thick layers min.1.5- DensDeck Screw or 2.67 ft'/ A4H inch-thick Loose laid N/A Nail and SB I 30 Or ACFoam II or DensDeck 3-inch fastener ACFoam III Prime Metal Plates ESR-1660 I Most Widely Accepted and Trusted Page 14 of 14 TABLE 4—ATTACHMENT METHODS FOR FULLY ADHERED MEMBRANE'(Continued) SYSTEM DECK Insulation'•' Coverboard' ADHESIVE' ALLOWABLE NO. UPLIFT Type Fastener' Rate Type Fastener' Rate CAPACITY (Ibf/ft') One or more Min.1/r Duro-Last layers min. 1.5- inch-thick Concrete A4J inch-thick Loose laid N/A DensDeck Screw or 3.2 fl I SB I 30 ACFoam II or or Nail and fastener ACFoam III DensDeck 3-inch Prime Metal Plates One or more Min.6/s- Duro-Last layers min.1.5- inch-thick Concrete A4K inch-thick Loose laid N/A DensDeck Screw or 4 fi=/ SB I 30 ACFoam II or or Nail and fastener ACFoam Ill DensDeck 3-inch Prime Metal Plates One or more /3 in. layers min. 1.5- Ashland Pliodeck wide A4L inch-thick Insulation ribbons None N/A N/A SB I 45 ACFoam II Adhesive spaced • • 12 in.o.c. 3/4 in. 3/4-inch Ashland Pliodeck wide Ashland wide A4M Min.2 in. ISO Insulation ribbons Min. /4 in. Pliodeck ribbons SB II 218 95+GL Securock Insulation spaced Adhesive spaced Adhesive 12 inches 12 in.o.c. o.c. Min.2-inch-thick Hot asphalt 25 lbs/sq. Atlas Roofing 25 lbs/sq. `ACFoam II, Hot asphalt or or or or `Hunter Panels Insta-Stik, 3/4 in. Insta-Stik, 3/4-inch Min.1/4 in. OlyBond wide A4N "H-Shield," OlyBond 500, wide Securock 500,Tite- ribbons SB II 248 Johns Manville Tile-Set or ribbons Set or spaced `ENRGY-3"or Weather-Tile spaced Weather- 12 inches Concrete Firestone 12 in,o.c. Tile o.c. (Continued) One or more A4P layers min.1.S Hot asphalt 25 lbs/sq. None N/A N/A SB I 45 inch-thick ACFoam II One or more A4Q layers min.1.5- Hot asphalt 25 lbs/sq. None N/A N/A WB I 75 inch-thick ACFoam II One or more A4R layers min. 1.5- Hot asphalt 25 lbs/sq. None N/A N/A SB II 38 inch-thick ACFoam II Min.'/cinch Georgia Pacific High One or more 3/4 tot- Density 3/4 to 1- layers min.1.0- inch Roof inch inch-thick Insta-Stik Roofing beads Fiberboard Insta-Stik heads A4S Plymouth Foam Adhesive spaced or Knights- Roofing spaced SB I or SB II 30 EPS or 12-inch Celotex Adhesive 12 inches Insulfoam EPS o.c. High o.c. Density Wood _ Fiberboard 3/4 to1- inch A4T Min. '/4-inch- Insta-Stik Roofing beads None N/A N/A WB I 38 thick DensDeck Adhesive spaced 12-inch o.c. For SI:1 inch=25.4 mm, 1 lbf/ft2=47.88 Pa, 1 lbf=4.4 N,1 sq=100 ft2of roofing. 'Insulations,fasteners,adhesives and membranes must be FM-approved. 'All foam plastic insulation must be UL Classified foam plastic,and must be limited to the maximum thickness in accordance with Section 5.5 of this report or the maximum thickness in accordance with this table,whichever is less.