12080189CITY OF CUPERTINO BUILDING PERMIT Ii1111.DING ADDRESS: 20650 VALLEY GREEN DR CONPRACFOR: STATEWIDC ROOFING PERMITNO: 12080189 INC OWNEWSNAME: SI50LI.0 5542 MONTEREY RD DATE ISSUED: 08 /172012 OWNER'S PIIONF: 4089961010 SAN JOSE, CA 95138 PlIONE NO: (408)288 -8680 ❑ LICENSEID CONI'RACI'OR'S DECLARATION .1011 DESCRIPTION: RF.SIDEls"HAL El COMMERCIA1 ( Z 6 License Class Lie. N �-- 2 �i COMM. RE -ROOF 29,900 SQ FT INSTALL 60 MILL TPO G �9 Contactor -- rf">�`Q.�tf� F\..r� Date `6 I SINGLE PLY OVERLAY ROOFING SYSTEM hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that tar license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have mud will maintain a certificate of consent to self-insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the Sq. FI Floor Area: Valuation: $29900 performance of the work for which this permit is issued 1 have and will maintain Worker's Compensaion Insurance, as provided for by Section 3700 ofthe Labor Code, for the performance of flue work for which this AI'N Number: 32610053.00 OecupanO. Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read tliis application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct. I agree to complywith all city and county ordinances mid state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction; and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save 180 DAYS FROM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may aceme against said City in consequence of tie Issued by: ! % / ` Date: U 2 granting of this permit. Additionally, the applicant understands and will comply with all non-po source regulatims p c he Cupertino bunicipal Code, Section 9.18. I2P: ROOFS Signature Date? 2 All roofs shall be inspected prior to any roofing material berg installed If u roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION /•!�"�'` Signature of ApplicthnC ` -C L/ tea[, I hereby affirm that 1 um exempt from the Contractor's License Law for one of / ( the following boo reasons: ALL ROOF COVERINGS "r0 ta" .ASS "A" OR 11 VI-1 ER 1, as owner ofthe property, or my employees with wages as their sole comfunsation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business d Professions Code) I, as owner ofthe property, am exclusively contracting with licensed contractors to 11\%\RDOIIS MATERIALS DISCLOSURE construct the project (Sec.7044, Business & Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Ilealth & Safety Code. Sections' - 5505.25533, and 25534. 1 will 1 hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code. Chapter 9.12 and the declarations: Ilealth & Safety Code. Section 25532(x) should I store or handle hazardous I have mid will maintain a Certificate of Consent to self-insure for Worker's material. AJditionally..should 1 use equipment or devices which emit hazardous Compensation, as provided for by Section 3700 ofthe Labor Code, for the air contaminants as defined by the Isay Area Air Quality Management District performance ofthe work for whichthis permit is issued. will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 ofthe Labor Code, for the performance of tin work for which this (he Ilydlh & Safety Code, Sect Its 25505, 255" 1 iJ 25534. /2 Owner or authorized agent--^ Date: permit is issued. I certify that in the performance ofthe work for which this permit is issued, I shall not employ any person many manner so as to become subject to the Worker's Compensation laws of California. If,, after making this certificate of exemption, I CONSTRUCHON LENDING ACH;NCI' become subject to the Worker's Compensation provisions of the Labor Code, I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked, work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name .U'I'LIC. \N I'CI ?R'I'IPIC. \'1'10N Lender's Address 1 cenifv that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state Imes relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupenino against liabilities, judgments, ,U2CI11'I'F:('I "S I1F.CLAIL \'f10N costs, and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. gaming of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per tat Cupenino Municipal Cade, Section Licensed Professional 9.18, Signature Date CITY OF CUPERTINO FEE ESTIMATOR - BUILDING DIVISION W 20650 valleuy green dr. IAPN: DATE: 08117/2012 REVIEWED BY: bobs. NADDRESS: Plumb. Permit Fee: BP #: 'VALUATION: $29,900 'PERMIT TYPE: Building Permit PLAN CIIECR TYPE: Alteration / Addition / Repair PR11 LAR1' USE: Commercial Building Elect Insp. I, ew: PENTA MATION PERMITTYPE: 1COMMLROO i WORT: install a 60 mil TPO single ply overlay roofing system. SCOPE $0.00 NOTE: This estimate rocs not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sneer District, School District, etc.). These lees are based on the prelindnan• information available and are mill, an estimate. Contact the Dent for aildn'I info. FEE ITEMS (Fee Resolution I/- Eff 7 /l /!U Nech. Plan Check Plumb. Plan Check Elec.. flan Check Wech. Permit Fee: Plumb. Permit Fee: Efec. Permit Fee: Other ,ilech. tarp. Other Plumb Inep. Other Etc,,. Lisp. El Mech. lay. Few: Plumb. Inp. Fee: Elect Insp. I, ew: NOTE: This estimate rocs not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sneer District, School District, etc.). These lees are based on the prelindnan• information available and are mill, an estimate. Contact the Dent for aildn'I info. FEE ITEMS (Fee Resolution I/- Eff 7 /l /!U FEE QTY /FEE MISC ITEMS Plan Check Fee: $0.00 29,900 S. f.. $2,037.00 Re roof IRF-ROOFC0,11 Suppl. PC Fee: (D Reg. Q OT 0.0 -its- $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:Q Reg. Q OT 1 0.0 1 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Construction Tax: Administrative Fee: O E) Work Without Permit? 0 Yes 0 No $0.00 Advanced Plannine Fee: $0.00 Select a Non - Residential Building or Structure G 0 i Trace/ Docutnenmrion Fees: Strong Motion Fee: IBSEISAIICo $6.28 Select an Administrative Item Blda Stds Commission Fee: IBCBSC $2.00 SUBTOTALS: $8.281$2,037.001 TOTAL FEE: $2,045.28 Revised: 07/01/2012 Electrical Excavation CUPERTINO REROOF PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014 -3255 Q OI (408) 777 -3228 • FAX (408) 777 -3333 • buildino(7a cuoertino.oro \ 00 PROJECT ADDRESS 20650 Valley Green Drive APNp Z(p 10 x.53 OWNER NAME Apple, Inc. PHONE 408- 996 -1010 E.MAII. STREHrADDRF_SS 1 Infinite Loop CITY, STATE ZIP Cupertino, CA 95014 FAX CONTACT NAME Mike Courtney PHONE E -MAIL STREhTADDRFSS CITY, STATT ZIP FAX ❑ OWNER ❑ OWNFA- BUIDER ❑ OWNERAGDIT Lt CoN1RACr0R ❑ CON RALTOR AGI'XT ❑ ARCFNn:Cr ❑ ENGIND'R ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME Mike Courtney LICFNSENUMBER 803926 LICENSE TYPE C39 BUS. LIC.H COMPANYNAME Statewide Roofing, Inc. E -MAII- mbotill @swroof.net FAX 408- 286 -7820 SI'REITADDRESS 5542 Monterey Road, #201 CITY,STAmziP San Jose, CA 95138 PIIONE408- 286 -7828 ARCHn'ECmNGINEER NAME N/A LICENSE NUMBER BUS. LIC. 0 COMPANY NAME E -MAIL FAX STREETADDRTS.S CITY, STATE ZIP PHONE USE OF ❑ SI'D or Duplex ❑ Multi - Family STRUcrum: [N Commercial ROOF ARM: 29,900 sf VALUATION: $87,000 EXISTING ROOFTYPE IKBUILT- UPROOF ❑ASPHALTSDINGLES ❑WOODSIIAKES 0WOODSHINGW3 ❑OTIIF:R(SPFCIP\) REmovrmEPLACE OYES L'l NO IF NO. I H LAYERS: PLYWOOD ❑ Y." ❑ _ THICKNESS: ❑ W PLYWD ❑ OSB "TYPE. ❑ COX PI'rCIE —:12 ROOF CLASS: A ,yy PROPOSEDROOFTYPE ❑BUILT- UPROOF ❑ASPHALTSHINGLES 13 WOOD SHAKES 11 WOOD SHINGLES ff OIT11:R Overlay ITC -ES REPORT# DESCRIPTION OF WORK: Install a 60 mil TPO single ply overlay roofing system. By my signature below, I certify to each of the following: I= the property owner or authorized agent to act on the property owner's behalf. I have lead this application and the information I have provided is correct. I Description of Work and verify it is accurate. 1 agree to comply with all applicable local ordinances and state laws relaim g co ze representatives orCuperlino to enter the above- identi lied properly for inspection purposes. Signature of ApplicanUAgcnt: Date: 8/15/12 SUPPLEMENTAL INFORMA'T'ION RE - _ If building is associated with a I lome Owner's Association, provide letter of approval from I -IOA. PTOVI 'Plannl0g approval f0 VCDIy If there tiny restrictions. rovldc copy of Manufacturer's Installation Specifications. -.' Frovide signed copy of Cupertino's Tear -Off Policy. OFFICE USE ONLY ' PI1 N CHECK 1YPF. SRoIrri,CC SI.EP Q— rrvER= rIIE -r.o IjN t :R ❑ 41 \PREtiti ❑ s•rANDARo , � n BIBI,IIING PIAN REVIEW ❑ PIANNIh'C PL \N RE \'IF. \ \' ❑ FIRF. DKPr ❑ oIT1ER: Reroofilpp_201l.doc revised 03116111 44F. NEW CONSTRUCTION , - I 90= �G6a rrF E • r CARLISLE'S 1 pical Application OSure -Weld Reinforced Membrane ® Carlisle Fasteners and Plates Acceptable Insulation ® Approved Roof Deck System features and benefits include: saw • Ileac- weldable membranes �,- _ = •O ` h— (((�� • Iligh wind uplift performance • Ilail and high puncture resistance I L • Top ply membrane thickness adds improved ' long -teen weatherability and durability • Sure-Weld membrane meets FARGY STAR° guidelines �Ci�, IT Sure -Weld Membrane for Mechanically- Fastened i.E) Systems is available in the following: AUG 1 g 2012 Colors: white, Grae,'lan Thickness (mils): 45, 60, i? and SO Standard Widths: 6', 3', 10' and 12' Standard Lengths: 100' FOR TEAR OFF OPTIONS REFER TO NEW CONSTRUCTION ABOVE. ' Reler to Carlisle's Sure -Weld Design Criteria Portion For current Code Approvals and Warranties, visit Carlisle's wehsite, of the Current Specification or contact a Design Analyst. SML,,l ROOFING AMERICA: OVER 40 YEARS AND 10 BILLION SQUARE FEErT. / BoSpree 80O -4-SY C P.O. 00C Incorporated 013 www.carlisle- syntec.com Fax:717.2aF71G3 markelOWlee.arlesle.com Carlisle SynTec Incorporated NEW CONSTRUCTION REROOFING 90= �G6a rrF E • r r & r 11 rrE �`{�,t,,C{� I173u13�'I7•F' ' rF DECK OVE N7 INSULATION NO NO HP MAT INSULATION INSULATION NO INSULATION *REFER TO REQUIRED IflEO SPECS RECOMMENDED CARLISLE POLYISO, CARLISLE HP RECOVERY BOARD OR f REFER TO NEW CONSTRUCTION INSULATIONS CARLISLE HP RECOVERY BOARD OVER POLYSTYRENE INSULATION CARLISLE FASTENERS AND PLATES f REFER TO NEW CONSTRUCTION ATTACHED BY HIM Fin MEMBRANE FASTENERS/ PIRANHA FASTENERS/ RPANHA LT.WT. DECK CD -ID/ PIRANHA PLATES; HP -X FASTEIIERSI I.T.W. DECK ATTACHED BY PLATES: HPXTPA FAST/ PLATES; HPXTRA FAST/ FASTENERS/ PLATES HO 1140 PIRANHA FASTENERS/ TO NEW CONSTRUCTION NHANHA PIRANHA FASTENERS PLATES PLATES XTRA PLATE XTRA PLATE FOR TEAR OFF OPTIONS REFER TO NEW CONSTRUCTION ABOVE. ' Reler to Carlisle's Sure -Weld Design Criteria Portion For current Code Approvals and Warranties, visit Carlisle's wehsite, of the Current Specification or contact a Design Analyst. SML,,l ROOFING AMERICA: OVER 40 YEARS AND 10 BILLION SQUARE FEErT. / BoSpree 80O -4-SY C P.O. 00C Incorporated 013 www.carlisle- syntec.com Fax:717.2aF71G3 markelOWlee.arlesle.com Carlisle SynTec Incorporated CARLISLE'S SURE -WEB® The Sure -Weld Mechanically - Fastened hoofing System now offers wider membrane options: 6, 8', 10' and 12'. y- Fasten :d • Sure - Weld's « Ilectivity values exceed other heat- welded membranes • Membranes are eco- friendly as they do not contain chlorine or plasticizers • Sure - Weld's top -ply surface is thicker and smoother than other membranes in the market, providing better welding results and reduced din pickup System Codes Project Information • UI. Class A. Band Universal Slope ratings are available This Sure -Weld Roofing System is being installed for the project named over anv deck type below: • FM Uplift values up to 135 psf can be achieved name: cirv: stale: The Carlisle Authorized Roofing Contractor is: company name: address: ciw: state: zip: Installation Carlisle's Sure -Weld Mechanically- Fastened Roofing System utilizes white, gray or tan membranes in standard reinforced 45- or 60 -mil thickness- or 72- or 80 -mil thick reinforced Sure -Weld EXTRA" Insulation is mechanically fastened to an acceptable roof deck. Sure -Weld membrane sheets are mechanically fastened to the deck Hill Carlisle 11M or I U'Stra Fasteners and appropriate Piranha Plates. Adjoining sheets are overlapped and joined together with a minimum I %" aide hot air weld. The above information represents a typical Carlisle Sure-Weld Mechanically- Fastened Roofing System. Refer to Carlisle's published specifications and details for more complete information. Sure -Weld Membrane Strengths • Sure -Weld membrane is available in white, gray and tan; 6'-, 8' -, 10'- and 12'- widths • When tested for puncture resistance. Sure-Weld results were better than competitive heat weldable membranes (PVC and Iiypalon) • Because Sure - Weld's rellectivity values exceed indusup standards, the membrane meets the criteria for the E A's and DOE 's ENERGY STAR• Program For code specifics, refer to Carlisle's SW Code Approval Guide. Quality Assurance Carlisle Authorized Roofing Contractors have received training to install Carlisle's Sure -Weld Roofing Systems. Inspection Upon installation completion, and prior to the issuance oft membrane systeni warranty, an inspection will be conducted by a Carlisle Technical Representative. Warranty Consult your roofing contractor or Carlisle Manufacturer's Representativ e/Distributor for associated warranty charges. This system, properly installed and inspected on a commercial project may receive. • A 5- or 10 -year Membrane System Warranty; peak gust wind speed coverage up to 55 mph • A 10 -year Total System or 15 -year Golden Seal Warramy may be requested when all materials used for die roofing installation are manufactured or marketed by Carlisle • A 20 -vrar Golden Seal \1Warruuv is salable with Sure - Weld's 72- and SO -mil LC RA T1'0 membranes • Higher wind speed warranties (up to 100 mph peak gust wind speed) available upon revieny by Carlisle • A l0 -vear Re ctivity \CWammry (based on 15CIiRG1' STAR° criteria) available in white mcnibrume • A 10 -, 15-, 20 -year Puncture Warranty with Sure -Weld 72- 80 -111il For more specifics or for International warranty programs, contact Carlisle. 1 WUL \.SSIF / 3ME,,1 ROOFING AMERICA: OVER 40 YEARS AND 10 BILLION SQUARE FEET,. 8UUA�(1� � Carlisle aM S.EWeln, FAST Mhmive REPRINT REQUEST Ceer '� Q -4 J art CaAale vaJenurin. 600148 - -SW -MF Syslc Subm:aal SAen' -042505 www.carlisle- syntec.COM ENERGY STAR samgk wvxly C2008 Wale SynT%.mmmm Carlisle SynTec Incorporated amed"USIIMMMm Ponied In USA. CARLISLE'S SUREmWELD° REINFORCED TPO MEMBRANE Overview Carlisle Sure -Weld membrane is a premium heat - weldable single -ply thermoplastic polyolerin (TPO) sheet designed for new roof construction and re- roofing applications. Sure -Weld High Slope (HS) membrane is formulated with additional Flame retardant (compared to Standard) for higher -slope fire code approvals. Sure -Weld EXTRA is 72- and 80 -mil thicknesses for significantly higher strength and weatherability. Carlisle's Sure -Weld TPO membrane is based on advanced polymerization technology that combines the flexibility of ethylene - propytene (EP) rubber with the heat weldability of polypropylene. All Sure -Weld TPO membranes include OctaGuard XTTM, an industry- leading, state-of-the-art weathering package. OctaGuard XT technology enables Sure -Weld TPO to withstand extreme weatherability testing intended to simulate exposure to sever climates. Physical properties of the membrane are enhanced by a strong polyester fabric that is encapsulated between the TPO -based top and bottom plies. The combination of the fabric and TPO plies provides Sure -Weld reinforced membranes with high breaking strength, tearing strength and puncture resistance. The relatively smooth surface of Sure -Weld membrane produces a total surface fusion weld that creates a consistent, watertight monolithic roof assembly. The membrane is environmentally friendly and safe to install. Sure -Weld Standard and HS products are available in highly reflective white, tan and gray, in both 45 -mil and 60 -mil thicknesses. Sure -Weld E(TRA products (including HS) are available in 72 -mil and 80 -mil thicknesses in white, gray and tan. Sixteen special colors are also available (see Carlisle's TPO Color Palette brochure). Available widths are 4-, 5- and 6 -ft perimeter sheets and 8-, 10- and 12 -ft field sheets. In Roofing Solaf Eons for Over 45 Years Carlisle's Sure -Weld tan and white TPO membrane can contribute toward LEED• (Leadership in Energy and Environmental Design) credits. Tan and white Sure -Weld are ENERGY STAR°'- qualified and California Titre 24 compliant. Features and Benefits • Outstanding puncture resistance • Chlorine -free with no halogenated flame retardants • Plasticizer -free; does not contain liquid or polymeric plasticizers • Excellent low temperature impact resistance • Excellent chemical resistance to acids, bases and restaurant exhaust emissions • Exceptional resistance to heat, solar UV, ozone and oxidation • Low water vapor permeance and water absorption • Hot -melt extrusion processed for complete scrim encapsulation • Warp- knitted fabric (not woven) for smooth surface and greater thickness over scrim • Sure -Weld is 100% recyclable (refer to Carlisle's Recyclability Statement) Installation Sure -Weld Roofing Systems are quick to install as minimal labor and few components are required. The systems may be installed utilizing labor- saving devices that make sheet welding fast, clean, consistent and easy to learn, while reducing strain on the roofing technician. The Carlisle Mechanically Fastened Roof System installation starts with the insulation fastened with a minimum of 5 fasteners per 4 by 8 ft. board. The Sure -Weld reinforced membrane is mechanically fastened to the deck using HP -XT"' Fasteners and Piranha PlatesTM or HP -XTRA Fasteners and Piranha XTRA Plates. Adjoining sheets of Sure -Weld membrane are overlapped over the fasteners and plates and joined together with a minimum 114- inch -(4 cm) wide hot -air weld. The Carlisle Fully Adhered Roofing System application begins with the insulation fastened at the required density (max.1 every 2 sq ft) necessary to resist the appropriate wind load. The substrate and membrane are coated with an appropriate Sure -Weld Bonding Adhesive and the membrane is rolled into place. CONSULT CARLISLE SPECIFICATIONS FOR COMPLETE INSTALLATION INFORMATION. Box 7000 • Carlisle, PA 17013 • Fax: 717- 245 -7053 • www.carlisle- syntec.com Carlisle SynTec CARLISLE'S SUREoWELD REINFORCED TPO MEMBRANE Precautions 1. Sunglasses that filter out uttraviolet light are strongly recommended as tan and white surfaces are highly reflective. Roofing technicians should dress appropriately and wear sunscreen to protect skin. 2. Surfaces may become slippery due to frost and ice buildup. Exercise caution during cold conditions to prevent falls. 3. Care must be exercised when working close to a roof edge when surrounding area is snow- covered as the roof edge may not be clearly visible. Properties and Characteristics' 4. Use proper stacking procedures to ensure sufficient stability of the rolls. 5. Exercise caution when walking on wet membrane. Membranes may be slippery when wet. 6. Store Sure -Weld membrane in the original undisturbed plastic wrap in a cool, shaded area and cover with light- colored, breathable, waterproof tarpaulins. Sure -Weld membrane that has been exposed to the weather must be prepared with Weathered Membrane Cleaner prior to hot -air welding. Physical Property ASTM 06878 Requirement 45 -mil 60 -mil 72 -mil EXTRA 80 -mil EXTRA Tolerance an nominal thickness, % 15,-10 -10 - 10 - 10 - 10 Thickness over scrim, in. (mm) 0.012 min 0.018 typ 0.024 typ 0.030 typ 0.034 typ ASTM 06878 optical method. (0.305) (0.457) (0.610) (0.762) (0.864) average of 3 areas 0.10 max 0.10 max ASTM E96 uac. B 0.05 typ 0.05 typ Breaking srergtn. mf W 220 (976 M 225 (1.0) min 250 (1.1) min 350 (la) min 35011.6) min ASTM 0751 grab method min 320 (1.4) typ 360 (1.6) typ 400 (1.8) typ 425 (1.9) typ Elongation break of reinforcement, % 15 min 15 min 15 min 15 min 15 min . ASTM D751 grab method 25 typ 25 typ 25 typ 25 typ Tearing strength, lot (N) 55 (245) min 55 (245) min 55 (245) min 55 (245) min 55 (245) min ASTM 0751 proc. B 8 in. x 8 in. 90 min 130 (578) typ 130 (578) typ 130 1578) typ 130 (578) typ - Brittleness point, °F ( °q -40 ( -40) max -40 (40) Max - 40(.40) Max -40 (40) Max -40 ( -40) max ,ASTM D2137 - 1.0 max -50 ( -46) typ . 501-461 ryp -50 (.46) typ -50 ( -46) typ linear dimensional change, % - 1 max - 1 max - 1 max - 1 max z 1 max I ASTM D1204, 6 nouns at 158 °F particular property of -0.2 typ -0.2 typ -0.2 typ -0.2 typ ',Ozone Resista al, no cracks 7X PASS PASS PASS PASS PASS 1 ASTM 01149. 100 ephm, 168 hm water absorplum resistance, mass % - 3.0 max - 3.0 max - 3.0 max e: 3.0 max c 3.0 max ASTM 0471 top surface Only 2.0 typ 2.0 typ 2.0 typ 2.0 typ ,166 hours at 158 °F vrater Factory seam strength, IbMn Wm) 66 (290) min 66 (290) min 66 (290) min 66 (290) min 66 (290) min ' 'Feld seam Strength, IblAn (kN1m) No requirement 25 (4.4) min 25 (4.4) min 40 (7.0) min 40 (7.0) min ASTM D1876 tested in peel 50 (8.8) typ 60 (105) typ 65 (11.4) typ 70 (12.31 typ Water vapor penneance, Perms No requirement 0.10 max 0.10 max 0.10 max 0.10 max ASTM E96 uac. B 0.05 typ 0.05 typ 0.05 typ 0.05 typ 1 Puncture resistance, ml (kN) No requirement 250 (1.1) min 300 (1.3) min 350 (1.6) min 400 (1.8) min I 'FTM 101 C, method 2031 325 (14) typ 350 (1.6) typ 400 (1.8) typ 45012.0) typ (see supplemental section) Pmpert es after heat aging ASTM 0573, 670 hours ® 240 °F 'Breaking strength, %retained 90 min 90 min 90 min 90 min 90 min ,Elongation reml., % retained 90 min 90 min 90 min 90 min 90 min Tearing Strength, %retained 60 min 60 min 60 min 60 min 60 min Weight ct ange. % - 1.0 max - 1.0 max - 1.0 max - 1.0 max - 1.0 max Typical Weights 0.23 U112 (1.1 kglmr) 0.29(l.4) 0.35(l.7) 040 (2.0) Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information is intended as a guide and does not reflect the specification range for any particular property of this product. Invesfing In Roofing Solutlons for Over 45 Years 800- 479 -6832 • P.O. Box 7000 • Carlisle, PA 17013 • Fax: 717- 245 -7053 • www.Carlisle- syntec.com Carlisle SynTec CARLISLE'S SUREmWELD REINFORCED TPO MEMBRANE Extreme Testing For Severe Climates ASTM Standard 06878 is the material specification for Thermoplastic Polyolefn Based Sheet Roofing. It covers material property requirements for TPO roof sheet and includes initial and aged properties after heat and xenon -arc exposure. As stated in the scope of the standard, "the tests and property limits used to characterize the sheet are values intended to ensure minimum quality for the intended purpose." Carlisle's goal is to produce TPO that ensures maximum performance for the intended purpose of roofing membranes. Maximum performance requires the membrane to far exceed the requirements of ASTM D6878. For severe climates like Miami, FL and Phoenix, AZ, EXTREME testing is required. Heat Aging accelerates the oxidation rate that roughly doubles for each 10•C (18 °F) increase in roof membrane temperature. Oxidation (reaction with oxygen) is one of the primary chemical degradation mechanisms of roofing materials. Carlisle Extreme Testing Aging ASTM REQUIREMENT SURE -WELD REQUIREMENT ASTM TEST 240 °F 60 hours or 4 weeks 5,376 hours or 32 weeks* Carlisle 275 °F Extreme T851 N/A 1,344 hours or 8 weeks Extreme '-Compaattle to 1,024 weeks (20 yrs) at 185 °F for 6 ors/day. • Test specimen is 1" by 4" piece of 45-mil membrane unbacked, placed in circulating hot -air oven. • Criterion — no visible cracks after bending aged test specimen around 0.25 " - diameter mandrel. Xenon -Arc exposes the membrane samples to the combined effect of ultraviolet, visible and infrared radiation as well as ozone, heat and water spray, to greatly accelerate the effects of outdoor weathering. The radiation dose is measured in kilojoules per square meter (kJ /m) at 340 nm machine W wavelength. The irradiance power of the xenon - arc lamp is measured in Watts per square meter (W /m). 'Carlisle Extreme Testing — Xenon-Arc ' SURE -WELD RESULTS j ASTM TEST ASTM 06878 60 -MIL 80 -MIL 45 -MIL 72 -MIL REQUIREMENT kJ /meat 340 nm 10.080 20,160 27,720 17,640 25,200 • Test specimen is 2.75" by 5.5" piece of membrane, unbacked, weathering side facing arc lamp. • Criterion — no visible cracks viewed under I Ox magnification while wrapped around 3 "- diameter mandrel. In Rooflng Soluflons for Over 45 Years 800- 479 -6832 • P.O. Box 7000 • Carlisle. PA 17013 • Fax: 717- 245 -7053 Environmental Cycling subjects the membrane to repeated cycles of heat aging, hot -water immersion or acid fog followed by xenon -arc exposure. The acid fog accelerates acid etching that may occur from acid rain if the roof membrane is not resistant to acidic conditions. • ASTM requirement — none • Carlisle EXTREME test': • 10 days heat aging at 240•F (116 °C) followed by • 5 days water immersion at 158•F (700C) or with another specimen set • 5 eight -hour cycles in Kesternich sulfur dioxide chamber (sulfurous acid fog) followed by • 5040 kJ /m, (2000 his at 0.70 W /m= irradiance) xenon -arc exposure 'Test specimen is 2.75" by 5.5" piece of membrane with edges sealed. 'Criterion — after 3 complete cycles, test specimens shall remain flexible and not have any cracking under IN magnification while wrapped around a 3 "- diameter mandrel. Carlisle SynTec CARLISLE'S ouQm��Jwm[D Eimp@M(n[D rww 4p0 b&P.P& B N Supplemental Approvals, Statements 3. Sure -Weld TPO membranes conform to requirements of the and Characteristics: U.S.E.P.A. Toxic Leachate Test (40 CFR part 136) performed by 1. Sure -Weld TPO meets or exceeds the requirements of ASTM an independent analytical laboratory. 06878 Standard Specification for Thermoplastic Polyolefin Based Sheet Roofing. 2: Radiative Properties for ENERGY STAR, Cool Roof Rating Council (CRRC) and LEED. Solar Reflectance Index (SRI) is calculated per ASTM E1980. The SRI is a measure of the roof's ability to reject solar heat, as shown by a small temperature rise. It is defined so that a standard black (reflectance 0.05, emittance 0.90) is 0 and a standard white (reflectance 0.80, emihance 0.90) is 100. Materials with the highest SRI values are the coolest choices for roofing. Due to the way SRI is defined, particularly hot materials can even take slightly negative values and particularly cool materials can even exceed 100. rG& Test Method White TPO Tan TPO Gray TPO 'ENERGY STAY initial solar reflectance Solar Spectrum Reflectometer 0.87 0.68 WA i 'I ENERGY STAR inidal solar reflectance !after 3 years solar Spectrum Reflectometer (after cleaning) 0.83 0.64 WA j 1 CRRC Initial solar reflectance ASTM C1549 0.79 0.71 046 •CRRC solar reflectance ,after 3 years ASTM C1549 (uncleared) 0.70 0.64 0.43 ;CRRC initial ,thermal emittance ASTM C1371 0.90 0.86 0.90 i CRRC inermal emihance after 3 years ASTM C1371 (uncleared) 0.86 0.87 0.88 l I LEED thermal emittance ASTM E408 0.95 0.95 0.95 ' :SRI (Solar Reflectance Index) ASTM E1980 110 Be 55 1 Solar Reflectance Index (SRI) is calculated per ASTM E1980. The SRI is a measure of the roof's ability to reject solar heat, as shown by a small temperature rise. It is defined so that a standard black (reflectance 0.05, emittance 0.90) is 0 and a standard white (reflectance 0.80, emihance 0.90) is 100. Materials with the highest SRI values are the coolest choices for roofing. Due to the way SRI is defined, particularly hot materials can even take slightly negative values and particularly cool materials can even exceed 100. rG& 'Pre- consumer Recycled Content 10% Post- consumer Recycled Content 0% Manufacturing Location Senatobu, MS Tocele, UT Solar Reflectance Index 110 In Roofing Soluffons for Over 45 Years 4. Sure -Weld reinforced TPO was tested for dynamic puncture resistance per ASTM D5635 -04 using the most recently modified impact head. 45 -mil was watertight after an impact energy of 12.5 J (9.2 h -lbf) and 60 -mil was watertight after 22.5 J (16.6 ft -lbQ. Both 72 -mil and 80 -mil EXTRA products were watertight after an impact energy of 30.0 J (22.1 ft- I151). Cafte. Sure -Wtld, edaguaN XT. PlraMa Plans and w -x are tradmwW of Carlisle. ENERGY STAR is a repNared trademark awned by me OS. Govemment. LEED Is a trmemark of me US. Preen annotate Connell. Carlisle SynTec •DOGY STAR RuaelkaWn Is any wild In me OS. REPRINT CODE: 600515 - 'Sum-Weld ReiNmced TPO Membrane Product Data Stan' - 0505110 2011 Carlisle. ICC -ES Evaluation Report ESR -1463 V L ICC -ES /UL Dual Report Click on the logo to access UL Certification Reissued August 1, 2012 This report is subject to renewal October 1, 2014. www.icc- es.org 1 (800) 423 -6587 1 (562) 699 -0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00— THERMAL AND MOISTURE PROTECTION Section: 07 53 23— Ethylene - Propylene - Diene- Monomer Roofing Section: 07 54 19— Polyvinyl- Chloride Roofing Section: 07 54 23— Thermoplastic - Polyolefin Roofing REPORT HOLDER: CARLISLE SYNTEC INCORPORATED PO BOX 7000 CARLISLE, PENNSYLVANIA 17013 (717) 245 -7000 www.carlisle-syntec.com EVALUATION SUBJECT: CARLISLE EPDM, PVC AND TPO SINGLE -PLY ROOFING MEMBRANES ADDITIONAL LISTEES: VERSICO INCORPORATED POST OFFICE BOX 1289 CARLISLE, PA 17013 MULE -HIDE PRODUCTS COMPANY, INC. 1195 PRINCE HALL DRIVE BELOIT, WISCONSIN 53511 WEATHERBOND P.O. BOX 251 PLAINFIELD, PENNSYLVANIA 17081 KELLY COMPANY /2001 INC. 325 THOMASTON AVENUE WATERBURY, CONNECTICUT 06702 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2006 International Building Code® (IBC) ■ 2006 International Residential Code® (I RC) 2.0 USES Carlisle ethylene propylene diene monomer (EPDM), polyvinyl chloride (PVC) and thermoplastic polyolefin (TPO) single -ply roofing membranes are used as roof coverings in adhered and mechanically fastened membrane roofing systems. 3.0 DESCRIPTION 3.1 General: The EPDM, PVC and TPO Membrane Roofing Systems described in this report consist of single -ply roofing membranes, insulation where used, barrier board or slip sheet where used, flashing, mechanical fasteners and adhesives that are installed on a combustible or noncombustible deck. See Table 1 for Carlisle product trade names and corresponding product names for Mule -Hide Products Company, Inc., WeatherBond, Versico Incorporated and Kelly Company /2001 Inc., the additional listees. 3.2 EPDM Membranes: 3.2.1 Sure -Seal: Sure -Seal is a black, nonreinforced EPDM membrane available in 45-, 60- and 90-mil (1.14, 1.52, and 2.29 mm) thicknesses. 3.2.2 Sure -Seal FR: Sure -Seal FR is a black, nonreinforced EPDM membrane with fire retardants, available in 45 -, 60- and 90 -mil (1.14, 1.52, and 2.29 mm) thicknesses. !R33,2:3-';Sure- White: Sure -White is a white, nonreinforced E membrane available in a 60- and 90 -mil (1.52 and @11�2�f29 mm) thickness. Ei 3:2.4 Sure - Tough: Sure -Tough is a black, reinforced membrane consisting of a polyester reinforcement �en�capsulated between two EPDM membrane plies. It is �savailable in 45- to 75-mil (1.14 to 1.90 mm) thicknesses. " ?3.2.5 Sure -Tough FR: Sure -Tough FR is a black, reinforced membrane consisting of a polyester re0orcement encapsulated between two EPDM membrane plies with fire retardants. It is available in 45 to 60-mil (1.14 to 1.52 mm) thickness. ■ Other Codes (see Section 8.0) 3.2.6 Sure -Seal FleeceBACK: Sure -Seal FleeceBACK is Properties evaluated: a.45 -, 60- or 90 -mil (1.14, 1.52 or 2.29 mm) non - reinforced EPDM bonded to a 5.5- ounce -per- square -yard (0.18 • Weather resistance - _ kg /m2) polyester fleece. • Roof covering fire classification 3.2.7 Sure -White FleeceBACK: Sure -White FleeceBACK • Wind uplift resistance CEI`%�+ is a 60- or 90 -mil (1.52 or 2.29 mm) nonreinforced white EPDM bonded to a 5.5- ounce -per- square -yard (0.18 • Impact resistance AUG 16 201Z kg /m2) polyester fleece. v. as an a darren in, fthens je no! th he port or a eyremu tiorj r as us•ermMbs no .- nhmes in- spec wtuat o. Service oar are they to be construed as an rndorsrmenr ofrhe subject of the upon or a recommendation for its um. 7ilerr is no e�armnn• hr lCC E�nluarian Service. Lf.C. atrpreca or implied, as IM 11=11 toan)•frnaing or other matter in thisreport,orm toanyproduct coveredby her"". �•� - -- copyright 0 2012 Page 1 of 10 ESR -1463 I Most Widely Accepted and Trusted Page 2 of 10 3.2.8 Sure -Seal AFX: Sure -Seal AFX is a 45-, 60- or 90 -mil (1.14, 1.52 or 2.29 mm) non - reinforced EPDM bonded to a 7.5- ounce -per- square -yard (0.25 kg 1m2) polyester fleece. 3.2.9 Sure -Seal AFX PLUS: Sure -Seal AFX PLUS is a 60 -mil (1.52 mm) non - reinforced EPDM bonded to a 7.5- ounce -per- square -yard (0.25 kg /M2) polyester fleece. 3.3 PVC Membranes: 3.3.1 Sure -Flex and Sure -Flex Elvaloy: Sure -Flex and Sure -Flex Elvaloy are 50-; 60-, or 80 -mil (1.27, 1.52, or 2.03 mm) membranes consisting of a polyester reinforcement encapsulated between two plies of PVC. The membrane is available in white, gray or custom colors. 3.3.2 Sure -Flex FRS and Sure -Flex Elvaloy FRS: Sure - Flex FRS and Sure -Flex Elvaloy FRS are 50-, 60 -, or 80 -mil (1.27, 1.52, or 2.03 mm) membranes consisting of a fiberglass reinforcement encapsulated between two plies of PVC. The membrane is available in, white, gray or custom colors. 3.3.3 Sure -Flex FRS FleeceBACK and Sure -Flex Elvaloy FRS FleeceBACK: Sure -Flex FRS FleeceBACK and Sure -Flex Elvaloy FRS FleeceBACK are the Sure -Flex FRS membrane and the Sure -Flex Elvaloy FRS membrane, described in Section 3.3.2 with a laminated 5.5- ounce -per- square -yard (0.18 kg /my) polyester fleece backing. 3.4 TPO Membranes: 3.4.1 Sure -Weld: Sure -Weld is a 45- or 60 -mil (1.14 or 1.52 mm) membrane consisting of a polyester reinforcement encapsulated between two plies of TPO. The membrane is available in white, gray, tan or custom colors. 3.4.2 Sure -Weld HS: Sure -Weld HS is the Sure -Weld membrane formulated with an additional flame retardant for fire resistance at higher slopes. It is manufactured in 45- and 60 -mil (1.14 or 1.52 mm) thicknesses, and is available in white, gray, tan or custom colors. 3.4.3 SAT -TPO: SAT -TPO is a self- adhered version of Sure -Weld HS membrane with adhesive. 3.4.4 Sure -Weld EXTRA: Sure -Weld EXTRA is the same formulation as the Sure -Weld ,membrane but comes in 72- and 80 -mil (1.83 and 2.03 mm) thicknesses. 3.4.5 Sure -Weld HS EXTRA: Sure -Weld HS EXTRA is the same formulation as the Sure -Weld HS membrane but comes in 72- and 80 -mil (1.83 and 2.03 mm) thicknesses. 3.4.6 Sure -Weld FleeceBACK: Sure -Weld FleeceBACK is the Sure -Weld HS membrane, 45 or 60 mils (1.14 or 1.52 mm) thick with a laminated 5.5- ounce - per - square- yard (0.18 kg /m�) polyester fleece backing. 3.4.7 Sure -Weld AFX: Sure -Weld AFX is the 45 -mil (1.14 mm) Sure -Weld HS membrane with a laminated 10- ounce -per- square -yard (0.34 kg /m2) polyester fleece backing. 3.4.8 Sure -Weld AFX PLUS: Sure -Weld AFX PLUS is the 60 -mil (1.52 mm) Sure -Weld HS membrane with a laminated 10- ounce -per- square -yard (0.34 kg /M2) polyester fleece backing. 3.4.9 Spectro -Weld: Spectro -Weld is the Sure -Weld membrane, described in Section 3.4,1, and Sure -Weld EXTRA membrane, described in Section 3.4.4, formulated with a brighter white color. It is manufactured in 45-, 60-, 72- or 80 -mil (1.14 -, 1.52-, 1.83- or 2.03 -mm) thicknesses. 3.4.10 Spectro -Weld FleeceBACK: Spectro -Weld FleeceBACK is the Spectro -Weld membrane with a laminated 5.5- ounce -per- square -yard (0.18 kg /m2) polyester fleece backing. 3.5 Insulation: See Tables 2 through 4 for insulations for use with specific roofing systems. Foam plastic insulation, where used, must have a flame - spread index of not more than 75 when tested at the maximum thickness intended for use in accordance with ASTM E 84. 3.6 Barrier Board: Barrier board, where used, must be either minimum '/4- inch -thick (6.4 mm? G -P Gypsum Corporation "DensDeck," minimum /4- inch -thick (6.4 mm) Owens Corning "Slrataguard ", minimum '/4- inch -thick (6.4 mm) USG "Securock," or minimum '/2- inch -thick (12.7 mm) gypsum board. Barrier board must be UL- listed for roofing applications or UL- classified gypsum board. 3.7 Slip Sheet: The slip sheet, where used, must include Carlisle "FR Base Sheet 1S or 2S," Elk "VersaShield Underlayment," Elk "VersaShield FB -1S or FB -2S, or Atlas FR 10 or FR 50." 3.8 Flashing: Flashing must be provided in accordance with IBC Section 1503.2 or IRC Section R903.2, as applicable. Where flashing is of metal, the metal must be corrosion - resistant, minimum No. 26 gage [0.019 inch (0.483 mm)] galvanized steel. 3.9 Fasteners: Fasteners, used to mechanically attach insulation and membranes to the roof deck, must be corrosion - resistant, and must be Cadisle fasteners, plates or fastening bars, unless otherwise noted in this report. Refer to Table 4 for spacing of fasteners. 3.9.1 Sure -Seal HP Fastener: This is an epoxy - coated steel screw used in combination with Carlisle's fastening plates or bars to mechanically attach roofing insulation and membranes to steel or wood substrate. Fastener length must be selected to penetrate through the steel deck a minimum Of inch (19.1 mm), and into the wood deck a minimum of 1 inch (25.4 mm). 3.9.2 Sure -Seal HP Purlin Fastener: This is an epoxy - coated steel screw used in combination with Carlisle's fastening plates or bars to mechanically attach roofing insulation and membranes to structural steel members. Fastener length must be selected to penetrate through the steel member a minimum of 3/a inch (19.1 mm.) 3.9.3 Sure -Seal HD 14 -10 Fastener: This is a heavy - duty, epoxy- coated steel screw used in combination with Carlisle's fastening plates or bars to mechanically attach roofing insulation and membranes to concrete roof deck. Fastener length must be selected to penetrate into the concrete deck a minimum of 1 inch (25.4 mm). 3.9.4 Sure -Seal HP Polymer Seam Plate: This is a 2 -inch- diameter (50 mm) polymer plate designed to be used with Sure -Seal HP and Sure -Seal HD 14 -10 fasteners to mechanically attach roofing membranes to the roof deck. 3.9.5 Sure -Tite Fastener and ST Fastening Bar: This is a heavy -duty, epoxy- coated steel screw and bar used to secure reinforced EPDM membranes to steel or wood deck. The bar is 1- inch - wide -by- 0.040- inch - thick- by -10- foot -long (25.4 mm by 1.1 mm by 3.1 m) galvalume- coated steel with prepunched holes 6 inches (150 mm) on center. ESR -1463 I Most Widely Accepted and Trusted Page 3 of 10 3.9.6 HP -X Fastener: This is an epoxy- coated carbon steel screw used in combination with the Piranha Fastening Plate to mechanically attach TPO membranes to steel or wood substrate. Fastener length must be selected to penetrate through the steel deck a minimum of 3/4 inch (19.1 mm), and into the wood deck a minimum of 1 inch (25.4 mm). 3.9.7 Piranha Fastening Plate: This is a 23/s -inch- diameter galvalume- coated steel plate designed to be used with HP -X fasteners to mechanically attach PVC and TPO membranes to the roof deck. 3.9.8 HP -XTRA Fastener: This is an epoxy- coated carbon steel screw used in combination with the Piranha XTRA Fastening Plate to mechanically attach PVC and TPO membranes to steel or wood substrate. Fastener length must be selected to penetrate through the steel deck a minimum of 314 inch (19.1 mm) and into the wood deck a minimum of 1 inch (25.4 mm). 3.9.9 Piranha XTRA Fastening Plate: This is a 23/8- inch - diameter galvalumecoated steel plate designed to be used with HP -XTRA fasteners to mechanically attach PVC and TPO membranes to the roof deck. 3.9.10 OMG Inc. Rhino Bond Plate: The RhinoBond Plate is a 3- inch - diameter (76.2 mm), 0.028- inch -thick (0.7 mm) galvalume- coated steel plate, coated with a proprietary adhesive and used with the HP -X fastener to mechanically attach PVC and TPO membranes to the roof deck. The adhesive bonds the plate to the underside of the membrane. 3.10 Adhesives: 3.10.1 Sure -Seal 90- 8.30A: Sure -Seal 90 -8 -30A is a high - strength, solvent -based contact adhesive used to adhere EPDM membranes to the insulation or substrate. It has a coverage rate of approximately 60 square feet per gallon (1.5 m /L). The adhesive is supplied in 5- gallon (18.9 L) containers and has a shelf life of one year. 3.10.2 Sure -Seal Aqua Base 120: Sure -Seal Aqua Base 120 is a high- strength, water -based contact adhesive used to adhere EPDM and TPO membranes to the insulation or substrate. It has a coverage rate of approximately 120 square feet per gallon (3 m2/L). The adhesive is supplied in 5- gallon (18.9 L) containers and has a shelf life of one year. 3.10.3 Sure -Flex PVC Bonding Adhesives: Sure -Flex PVC and Sure -Flex Low VOC PVC Bonding Adhesives are high - strength, solvent -based contact adhesives used to adhere PVC membranes to an insulation or substrate. They have a coverage rate of approximately 60 square feet per gallon (1.5 m /L). The adhesives are supplied in 5- gallon (18.9 L) containers with a shelf life of one year. 3.10.4 Sure -Weld Bonding Adhesive: Sure -Weld Bonding Adhesive is a high - strength, solvent -based contact adhesive used to adhere TPO membranes to an insulation or substrate. It has a coverage rate of approximately 60 square feet per gallon (1.5 m2 /L). The adhesive is supplied in 5-gallon (18.9 L) containers with a shelf life of one year. 3.10.5 Low VOC Bonding Adhesive: Low VOC Bonding Adhesive is a high- strength, solvent -based contact adhesive used to adhere membranes to an insulation or substrate. It has a covera�e rate of approximately 60 square feet per gallon (1.5 m9/ L). The adhesive is supplied in 5- gallon (18.9 L) containers with a shelf life of one year. 3.10.6 FAST Adhesives: FAST 100, FAST 100LV, FAST Adhesive Dual Cartridge, FAST Adhesive Box Sets, Flexible FAST and FAST Bag -in -a -Box Adhesives are two- component polyurethane adhesives used to adhere FleeceBACK membranes and insulations to various substrates. The adhesives have a coverage rate of approximately 100 square feet per gallon (2.5 mZ /L). The adhesives are supplied in 15- gallon (56.7 L) and 50- gallon (189 L) drums, cartridge tubes or cylinders, and have a shelf life of one year. 3.11 Impact Resistance: The EPDM, PVC, and TPO roofing membranes described in this report meet requirements for impact resistance in IBC Section 1504.7, based on testing in accordance with FM 4470. 4.0 INSTALLATION 4.1 General: Installation of the EPDM, PVC, and TPO roofing membranes described in this report must comply with the applicable code, the manufacturer's published installation instructions and this report. The manufacturer's published installation instructions must be available at all times on the jobsite during installation. The substrate to which the membrane is to be applied must be clean, dry, and free of frost, loose fasteners, and other protrusions or contaminates that will interfere with the adhesion or attachment of the membrane or that will puncture the membrane. All materials must be protected against contact with incompatible materials. Where gypsum board is used as barrier board in the roofing assembly, weather protection must be provided to prevent damage to the gypsum board prior to application of the roofing membrane. The slope of the roof on which the single -ply membranes are installed must not be more than the maximum slope indicated for the particular assembly as listed in Tables 2 and 3. Penetrations and terminations of the roof covering must be Flashed and made weather tight in accordance with the requirements of the membrane manufacturer and the applicable code. 4.2 Fire Classification: 4.2.1 New Construction: The adhered and mechanically fastened EPDM, PVC, and TPO single -ply membrane roofing systems, when installed in accordance with this report, are Class A, B or C roof covering systems in accordance with ASTM E 108 and UL 790, as noted in Tables 2 and 3. 4.2.2 Reroofing: The existing deck must be inspected to verify that the structure to be reroofed is structurally sound and adequate to support and secure the roofing membrane. Prior to installation of new roof coverings, inspection by and written approval from the code official having jurisdiction must be required. Class A, B or C roof covering systems may be installed over existing classified roof covering systems under the following conditions without additional roof classification tests, provided the resulting classification is the lower of the new or existing roofing classification: ■ New uninsulated systems installed only over existing uninsulated assemblies. ■ New insulated systems installed over existing uninsulated systems only. 4.3 Wind Resistance: 4.3.1 New Construction: The allowable wind uplift pressures for the EPDM, PVC, and TPO roofing membranes as parts of roof assemblies are noted in Tables 4 and 5. ESR -1463 I Most Widely Accepted and Trusted Page 4 of 10 Metal edge securement for roofing systems must be designed in accordance with ANSI /SPRI ES -1, complying with IBC Section 1504.5. The edge securement for mechanically attached membranes was tested in accordance with ANSI /SPRI ES -1 Test RE -1, using Carlisle SecurEdge 300 (0.050 -inch (1.27 mm) 3003 aluminum] and Carlisle SecurEdge 3000 [0.040 -inch (1.02 mm) 3003 aluminum] fascia systems. The maximum allowable load for Carlisle SecurEdge 300 is 234 plf (348 kglm). The maximum allowable load for Cadisle SecurEdge 3000 is 200 plf (298 kg /m). 4.3.2 Reroofing: Mechanically anchored systems may be accepted based on the adequacy of anchors penetrating through existing roof coverings into structural substrates. Since the composition and /or condition of any particular existing underlying material may vary widely, reroofing with adhered systems is outside the scope of this report. 5.0 CONDITIONS OF USE The single -ply EPDM, PVC, and TPO roofing membranes described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Installation must comply with the applicable code, the manufacturer's published installation instructions and this report. The instructions within this report must govern if there are any conflicts between the manufacturers installation instructions and this report. 5.2 The adhered and mechanically fastened single -ply membrane roofing systems must be installed by professional roofing contractors who are trained and approved by the manufacturer. 5.3 Foam plastic insulation must be separated from the interior of the building by an approved thermal barrier in accordance with IBC Section 2603.4.1.5 or IRC Section R314.4, as applicable. 5.4 Foam plastic insulation, where used, must bear the label of an approved agency indicating that the foam plastic has a flame - spread index of not more than 75 when tested at the maximum thickness intended for use in accordance with ASTM E 84, subject to the approval of the code official. 5.5 Design wind uplift pressure on any roof area, including edge and corner zones, must not exceed the allowable wind uplift pressure for the system installed in that particular area. Refer to allowable wind uplift pressures for systems as listed in Table 4. 5.6 The allowable wind uplift pressures listed in Table 4 are for the roof covering system only. The deck and framing to which the system is attached must be designed for the applicable components and cladding wind loads in accordance with the applicable code. 5.7 When application is over existing roofs, documentation of the wind -uplift resistance of the composite roof construction must be submitted to the code official for approval at the time of permit application. 5.8 The roofing membranes are manufactured at Carlisle, Pennsylvania; Greenville, Illinois; Tooele, Utah; and Senatobia, Mississippi, under a quality control program with inspections by UL LLC (AA -668). 5.9 For buildings under the IBC, above -deck thermal insulation board must comply with the applicable standards listed in Table 1508.2 of the IBC. 6.0 EVIDENCE SUBMITTED Data in accordance with ICC -ES Acceptance Criteria for Membrane Roof Covering Systems (AC75), dated April 2007, (corrected December 2008). 7.0 IDENTIFICATION Each roll of the roofing membrane must bear a label noting the product name, the manufacturer's name (Carlisle SynTec Incorporated) or the name of the additional listee, the manufacturer's address or plant code, the ICC -ES evaluation report number (ESR- 1463), and the name or label of the inspection agency (Underwriters Laboratories Inc.). 8.0 OTHER CODES In addition to the codes referenced in Section 1.0, the products in this report were evaluated for compliance with the requirements of the following codes: ■ BOCA® National Building Code /1999 (BNBC) ■ 1999 Standard Building Code° (SBC) ■ 1997 Uniform Building Code'* (UBC) For compliance under the above codes, see Sections 2 through 7 of this report, except revise the following sections to read as follows: 3.8 Flashing: Flashing must be provided in accordance with SBC Section 1503.2, BNBC Section 1508.1 and UBC Section 1509, as applicable. Where flashing is of metal, the metal must be corrosion- resistant, minimum No. 26 gage [0.019 inch (0.483 mm)] galvanized steel. 3.11 Impact Resistance: The EPDM, PVC, and TPO roofing membranes described in this report meet requirements for impact resistance in BNBC Section 1505.4.2, and SBC Section 1504.6, based on testing in accordance with FM 4470. 4.3.1 New Construction: The allowable wind uplift pressures for the EPDM, PVC, and TPO roofing membranes as parts of roof assemblies are noted in Tables 4 and 5. 5.0 CONDITIONS OF USE The single -ply EPDM, PVC, and TPO roofing membranes described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 8.0 of this report, subject to the following conditions: See Sections 5.1 through 5.8, except revise Section 5.3 to read as follows: 5.3 Foam plastic insulation must be separated from the interior of the building by an approved thermal barrier in accordance with BNBC Section 2603.4.1.5, SBC Section 2603.5.1.5, and UBC Sections 2602.4 and 2602.5.3, as applicable. ESR -1463 I Most Widely Accepted and Trusted Option I Option 2 4�¢SSIFjFO AssiFle V� C UL %1=beane for Roofing Syvans a. to Extemal Fire Exposwe Scc UL Direc:aty of Prodnc:s Cerriiicd fm Canada .and UL Reofn? M=rwli and 5ystems Direc:oxy 60P6 4�SSIFjFO C UL US Diembixne for Roofm' Sjvems at to Extemal Fim Eicpecutc Scc Ui. Dirc mrry of Products CatiScd for Canada. wd IJL Roo:"m, Miataials and Systems D -venmy 6OP6 FIGURE 1— INSPECTION AGENCY LABEL 5of10 ESR -1463 1 Most Widely Accepted and Trusted Page 6 of 10 TABLE 1—PRODUCT NAMES CARLISLE PRODUCT MULE -HIDE PRODUCT WEATHERBOND PRODUCT VERSICO PRODUCT KELLY CO./ NAME NAME NAME NAME 2001 INC. PRODUCTNAME Sure -Seal Mule -Hide Standard WeatherBond RBR EPDM Versigard EPDM Membrane _ Sure -Seal FR Mule -Hide FR EPDM WeatherBond RBR FR EPDM Versigard Nonreinforced C- EPDM -C Membrane EPDM Sure -Tough Reinforced Mule -Hide Standard WeatherBond RBR Standard Versigard Reinforced C- EPDM -CR Reinforced EPDM Reinforced EPDM Membrane Sure -Tough FR Mule -Hide FR Reinforced VersigardFR Reinforced C- EPDM -CR Type 1 Reinforced EPDM _ Sure -White Mule -Hide White -on- WeatherBond RBR White EPDM Versigard Nonreinforced EPDM RF -White Black EPDM Membrane EPDM -White Sure -Weld Mule -Hide TPO -c WeatherBond PRO TPO Versiweld Reinforced TPO / White Membrane TPO Sure -Weld HS Mule -Hide TPO -c (FR) - Versiweld ES - SAT -TPO Mule -Hide SA -TPO WeatherBond PRO PAS TPO Versiweld CIA TPO - Sure -Weld EXTRA Mule -Hide TPO -c Extra WeatherBond PRO TPO Versiweld PLUS Membrane _ Sure -Weld HS EXTRA Mule- Hide TPO -c Extra Versiweld ES PLUS (FR) _ _ Sure -Weld FleeceBACK Mule -Hide TPO -c Fleece Versiweld VersiFleece Back _ _ Sure -Flex Mule -Hide PVC WeatherBond PRO PVC VersiFlex Reinforced Membrane PVC Membrane _ Sure -Flex FRS Mule -Hide FRS PVC VersiFlex FRS Membrane - Reinforced PVC - Membrane Sure -Seal 90 -8 -30A Mule -Hide Bonding WeatherBond RBR LC -60 Bonding G200SA Yellow 2001 Inc. Bonding Bonding Adhesive Adhesive Adhesive Substrate Adhesive Adhesive Sure -Seal Aqua Base 120 Mule -Hide Water -Based Aqua Base 120 Bonding Adhesive Aqua Base 120 Bonding Bonding Adhesive Bonding Adhesive Adhesive _ Sure -Weld Bonding Mule -Hide TPO -c WeatherBond PRO TPO Bonding Versiweld Bonding Adhesive Bonding Adhesive Adhesive Adhesive _ Sure -Weld Low VOC Mule -Hide TPO -c Low Versiweld LOW VOC Bonding Adhesive VOC Bonding Adhesive - Bonding Adhesive _ Sure -Flex PVC Bonding Mule -Hide PVC Bonding WeatherBond PRO PVC Bonding VersiFlex PVC Bonding Adhesive Adhesive Adhesive Adhesive _ Sure -Flex Low VOC PVC Mule -Hide Low VOC VersiFlex Low VOC PVC Bonding Adhesive PVC Bonding Adhesive _ Bonding Adhesive _ FAST 100 Adhesive Mule -Hide SP -100 FAST 100 Adhesive Adhesive _ _ FAST 100 LV Adhesive Mule -Hide SP- 100 -LT FAST 100 LV Adhesive Adhesive _ _ ESR -1463 I Most Widely Accepted and Trusted Page 7 of 10 TABLE 2 —FIRE CLASSIFICATION ASSEMBLIES — ADHERED ROOFING SYSTEMS'': SYSTEM ROOF DECK BARRIER BOARD INSULATION' MEMBRANE /MAX. ROOF SLOPE NO. CLASS OR SLIP SHEET Sure -Weld, Spectro -Weld - '/;:12 Any of the following insulations, Sure -Seal, Sure - Tough, Sure - White, Sure - 1 -inch min. to 6 -inch max. Seal FleeceBACK, Sure-Weld HS, SAT -TPO, 1 A Noncombustible thickness: Carlisle "SecurShield ",'Polyiso ", Sure -Weld FleeceBACK, Spectro -Weld Polyiso HP -H Hunter FleeceBACK - /2:12 Panels "H- Shield" or "H- Shield -CG" Sure -White FleeceBACK, Sure -Flex, Sure - Flex FRS - 2/.:12 '/r inch -thick fiberboard', 72 Sure -White FleeceBACK-- 2/<:12 inch -thick fiberboard or barrier board (see Section 3.6) over 5- Sure -Seal, Sure -Tough - 1:12 2 A Noncombustible — inch max Insulfoam EPS2,' /2- Sure - White, Sure -Seal FleeceBACK, Sure - inch- thick fiberboard or barrier Weld, Spectro-Weld, Sure -Weld HS, SAT - board (see Section 3.6) over TPO, Sure -Weld FleeceBACK, Spectro-Weld System No. 1 insulations FleeceBACK, Sure -Flex, Sure -Flex FRS - 1 12:12 Sure -White FleeceBACK- 3/.:12 Sure - White, Sure -Seal FleeceBACK - 11/2:12 Noncombustible or Sure - Tough, Sure -Weld, Spectro-Weld, Sure - Combustible - min. '%/ Barrier board Weld FleeceBACK, Spectro-Weld 3 A inch -thick (see Section 3.6) — FleeceBACK - 3:12 in. r plywood or min. Sure -Weld HS, SAT -TPO -4:12 /,Both -thick Sure -Seal FR, Sure -Flex, Sure -Flex FRS - unlimited slope Any of the following insulations, Sure- Weld_Spectro -Weld - '/4:12 Combustible - min. Barrier board 1-inch min. Sure -Seal, Sure- Tough, Sure - White, Sure - " /',inch -thick n (see Section 3.6) or to 6 -inch max. thickness: "SecurShield ", Seal FleeceBACK, Sure -Weld HIS, SAT -TPO, 4 A plywood othick in. plywood or min. Slip sheet: layers Slip Carlisle Polyiso Polyiso HP ", Sure -Weld FleeceBACK, Spectro -Weld FleeceBACK /2:12 Section 3.7) -H Hunter Panels "H- Shield" or - Sure -White FleeceBACK, Sure -Flex, Sure - "H- Shield -CG" Flex FRS - 2/.:12 Combustible - min. "/',inch Any of the following insulations, Sure -Weld, Spectro-Weld, Sure -Weld HS, 5 C -thick _ 2 -inch min. to 6 -inch max. SAT -TPO, Sure -Flex. Sure-Flex FRS - plywood or min. 7/ thickness: Carlisle 'Polyiso HP- unlimited slope ,inch-thick OSB. H" or Hunter Panels "H-Shield' Single layer of minimum 3.0" or double layer of minimum 1.5" 6 A Combustible — Carlisle -SecurShield Polyiso' or EPDM, PVC, and TPO Membranes - '/2:12 Hunter Panels "H- Shield -CG" Single layer of minimum 1.9" 7 B Combustible — Carlisle " SecurShield Polyiso" or EPDM, PVC, and TPO Membranes - '/2:12 Hunter Panels 'H- Shield -CG' For SI: 1 inch = 25.4 mm. 'All foam plastic insulation must be UL- classified foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less. 2See Section 3.10 for adhesive application rate. 2UL Classified EPS may be installed below min. 1- inch -thick Carlisle or Hunter Panels polyisocyanurate insulations (max slopel:12) or below min.' /rinch -thick Carlisle SecurShield HD or Hunter Panels H- Shield HD (max slope 2:12) on noncombustible decks. °Cadisle SecurShield HD or Hunter Panels H- Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When these two boards are used directly below the Sure -Weld membrane, the slope is limited to max. '12:12. °When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable. ESR -1463 I Most Widely Accepted and Trusted Page 8 of 10 TABLE 3 —FIRE CLASSIFICATION ASSEMBLIES — MECHANICALLY FASTENED ROOFING SYSTEMS' SYSTEM ROOF DECK BARRIER BOARD INSULATION' MEMBRANE /MAX. ROOF NO. CLASS OR SLIP SHEET I SLOPE Any of the following insulations, 1 -inch min. to "SecurShield Sure - Tough, Sure -Weld, Spectro-Weld, Sure -Flex, Sure - 1 A Noncombustible — 6 -inch max. thickness: Carlisle ", Flex FRS - '1x:12 Polyiso' or "Polyiso HP -H Hunter Panels 'H- 'H-Shield-CG" Sure -Weld HIS - 1'/2:12 Shield" or Sure -Tough FR - 2:12 4rinch -thick fiberboard', ' /2-inch -thick Sure- Tough, Sure -Weld HS, fiberboard or barrier board (see Section 3.6) Sure -Flex, Sure -Flex FRS - 1:12 2 A Noncombustible — over 5 -inch max Insulfoam EPS2,' /,inch -thick Sure -Weld, Spectro-Weld - fiberboard or barrier board (see Section 3.6) 1'/x:12 over System No. 1 insulations Sure -Tough FIR - 3'/2:12 Sure -Weld, Spectro -Weld, Sure - 3 A Noncombustible — To 5 -inch max: Insulfoam SP Weld HS, Sure -Flex, Sure -Flex FRS - %:12 Noncombustible or Sure - Tough, Sure -Weld, Combustible - min. Barrier board Spectro -Weld -3:12 4 A 12rinch -thick — Sure -Tough FR - 3'/2:12 plywood or min. (see Section 3.6) Sure -Weld HS, Sure -Flex, Sure - 2116- inch -thick OSB. Flex FRS - unlimited Combustible - min. Barrier board Any of the following insulations, 1 -inch min. Sure - Tough, Sure -Weld, ,s (see Section 3.6) to 6 -inch max. thickness: Carlisle Spectro-Weld, Sure -Flex, Sure- , 5 5 A plywood or min. or Slip sheet: 2 'SecurShield Polyiso' or'POlyiso HP -H ", Flex FRS - I2:12 2 /16 -inch -thick OSB. layers, (see Section Hunter Panels "H- "H- Sure -Weld HS, 1'12:12 3.7) Shield" or Shield -CG' Sure -Tough FR - 2:12 Combustible - min. Sure -Tough - 1:12 15/32- inch -thick -t Slip sheet, 2layers Sure -Tough FR, Sure Weld, 6 A. plywood min. (see Section 3.7) — Spectro -Weld, Sure -Weld HS, 21,6- inch -thick OSB. Sure -Flex, Sure -Flex FRS - 1 Ix:12 Combustible - min. Sure - Tough, Sure -Tough FR, B ,s /,2- inch -thick Slip sheet, 1 layer Sure -Weld, Spectro -Weld, 7 plywood or min. (see Section 3.7) — Sure -Weld HS, Sure -Flex, Sure - 2 /,v inch -thick OSB. Flex FRS - 02:12 Combustible - min. Any of the following insulations, 2 -inch min. ,s Izrinch -thick to 6 -inch max. thickness: Carlisle "SecurShield "Polyiso Sure -Weld, Spectro -Weld, 8 C plywood or min. — Polyiso' or ", 'H-Shield"or Sure -Weld HS, Sure -Flex, Sure- 116- inch -thick OSB. HP -H Hunter Panels H- Shield Flex FRS - unlimited CG" Single layer of minimum 3 -inch or double 9 A Combustible — layer of minimum 1.5 -inch Carlisle EPDM, PVC, and TPO "SecurShield Polyiso' or Membranes - '22:12 Hunter Panels "H- Shield -CG" Single layer of minimum 1.9 -inch Carlisle 10 B Combustible — ' SecurShield Polyiso' or Hunter Panels "H- EPDM, PVC, and TPO Shield -CG" or single layer of an inverted G3 Membranes - '/2:12 cap sheet. For SI: 1 inch = 25.4 mm. 'All foam plastic insulation must be UL- classified foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less. 2UL Classified EPS may be installed below min. 1- inch -thick Carlisle or Hunter Panels polyisocyanurate insulations (max slopel:12) or below min. ' /,inch -thick Carlisle SecurShield HD or Hunter Panels H- Shield HD (max slope 2:12) on noncombustible decks. 'Carlisle SecurShield HD or Hunter Panels H- Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When these two boards are used directly below the Sure -Weld membrane, the slope is limited to , 12:12. `When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable. ESR -1463 1 Most Widely Accepted and Trusted Page 9 of 10 TABLE 4 —WIND RESISTANCE - MECHANICALLY FASTENED ASSEMBLIES°'' SYSTEM MAXIMUM DECK' INSULATION' MEMBRANE MEMBRANE MAXIMUM MAXIMUM NO. ALLOWABLE FASTENING FASTENER FASTENER WIND UPLIFT SPACING ROW (psf) (Inches) SPACING' Foam plastic insulation' 2. 1 45 Noncombustible ' /rinch -thick fiberboard or Sure -Tough HP -X Fastener & Metal Fastening Bar 12 6 it 6 inches barrier board (See Sect. 3.6) 2 75 Noncombustible Same as System No. 1 Sure -Tough HP -X Fastener & 6 6 It 6 inches Metal Fastening Bar 3 52 Noncombustible Same as System No. 1 Sure -Tough HP Fastener & Polymer Seam Plate 6 9 ft 6 inches 4 45 Noncombustible Same as System No. 1 Sure -Tough Sure -Tile Fastener & 12 9 ft 6 inches ST Fastening Bar 5 30 Noncombustible Same as System No. 1 Sure -Tough HP Fastener & 12 9 it 6 inches (75 mil) Polymer Seam Plate 6 60 Noncombustible Same as System No. 1 Sure -Tough HP Fastener & 6 9 h 6 inches (75 mil) Polymer Seam Plate Sure -Weld, HP -X or HP -Xtra 7 45 Noncombustible Same as System No. 1 Sure -Weld EXTRA, or Fasteners with Piranha 12 7 It 6 inches Spectro-Weld or Piranha Xtr i Plates Sure -Weld, HP -Xtra Fasteners with 8 45 Noncombustible Same as System No. 1 Sure -Weld EXTRA, or piranha Xtra Plates 12 9 If 6 inches Spectro -Weld Sure -Weld, HP -X or HP -Xtra 9 60 Noncombustible Same as System No. 1 Sure -Weld EXTRA, or Fasteners with Piranha or Piranha Xtra 6 9 it 6 inches Spectro-Weld Plates Sure -Weld, HP -X or HP -Xtra 10 67 Noncombustible Same as System No. 1 Sure -Weld EXTRA, or Fasteners with Piranha 6 7 ft 6 inches Spectro-Weld or Piranha Xtra Plates Sure -Weld, HP -X or HP -Xtra 11 30 Noncombustible Same as System No. 1 Sure -Weld EXTRA, or Fasteners with Piranha 12 11 it 6 inches Specho -Weld or Piranha Xtra Plates Sure -Weld, HP -X or HP -Xtra 12 60 Noncombustible Same as System No. 1 Sure -Weld EXTRA, or Fasteners with Piranha 6 11 ft 6 inches Spectro-Weld or Piranha Xtra Plates 13 53 Noncombustible Same as System No. 1 Sure -Flex HP -X Fasteners with 6 6 it 4 inches Piranha Plates 14 83 Noncombustible Same as System No. 1 Sure -Flex HP -X Fasteners with 6 2 It 11 inches Piranha Plates HP -X or HP -Xtra 15 30 Noncombustible Same as System No. 1 Sure -Flex Fasteners with Piranha 18 6 it 4 inches or Piranha Xtra Plates HP -X or HP -Xtra 16 45 Noncombustible Same as System No. 1 Sure -Flex Fasteners with Piranha 12 6 It 4 inches or Piranha Xtra Plates 17 53 Noncombustible Same as System No. 1 Sure -Flex HP -X Fasteners with 12 2 It 11 inches Piranha Plates 18 45 Noncombustible Same as System No. 1 Sure -Weld HP -X Fasteners with 1 per 5.3 1`12 NIA OMG RhinoBond Plates 19 60 Noncombustible Same as System No. 1 Sure -Weld HP -X Fasteners with 1 per 4 112 NIA OMG RhinoBond Plates For SI: 1 inch = 25.4 mm; 1 ft = 0.305 m; 1 psi = 47.88 Pa. 'Foam plastic insulation must be any of the following (1 -inch min. to 6 -inch max. thickness): Carlisle "SecurShield Polyiso ", "Polyiso HP -H" Hunter Panels "H- Shield" or Hunter Panels "H- Shield- CG ". 'All foam plastic insulation must be UL- classified foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance with this table, whichever is less. 'Steel deck must be minimum No. 22 gage galvanized steel (base -metal thickness 0.030 inch (0.76 mm)]. Concrete must have a minimum compressive strength (f'.) of 2500 psi. See Section 5.6 of this report. °For existing metal roofing. the assemblies listed must be installed by fastening through the roofing and into structural members (pudins, angle iron, beams, etc.) capable of resisting all expected loads. The maximum allowable wind uplift (field) pressures are shown in Column 2. sUL Classified EPS may be installed below min. 1- inch -thick Carlisle or Hunter Panels polyisocyanurate insulations (max slopel:12) or below min.' /rinch -thick Carlisle SecurShield HD or Hunter Panels H- Shield HD (max slope 2:12) on noncombustible decks. 6 Carlisle SecurShield HD or Hunter Panels H- Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When these two boards are used directly below the Sure -Weld membrane, the slope is limited to '/2:12. ESR -1463 1 Most Widely Accepted and Trusted Page 10 of 10 Table 4 footnotes cont'd z When these systems are used for reroofing or recovering, installation must be in accordance with Sections 4.2.2 and 5.7 of this report, and IBC Section 1510, IRC Section R907, BNBC. Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable. 3 Fastener row spaces shown are for field of roof only. See Section 4.3 for recognized fascia systems for mechanically fastened roof assemblies. The maximum allowable load for Carlisle SecurEdge 300 is 234 plf (348 kg /m). The maximum allowable load for Carlisle SecurEdge 3000 is 200 plf (298 kg/m). Distance between the edge of the roof and the first row of fasteners must be determined accordingly. TABLE 5 —WIND RESISTANCE – ADHERED ASSEMBLIES' SYSTEM ALLOWABLE DECK' INSULATION / MIN. THICKNESS''' INSULATION MEMBRANE NO. WIND UPLIFT FASTENING TYPE (FIELD) (ps1) RATE 1 46 Combustible or '/z inch fiberboard' , "/zz inch OSB, or barrier board (See 7 er 2 h 1 EPDM, PVC and TPO Noncombustible Section 3.6) p Membranes Combustible or Carlisle'Polyiso HP -H' or 'SecurShield Polyso': Hunter "H-Shield' 'H- z EPDM, PVC and TPO 2 45 Noncombustible Panels or Shield -CG' / 1. inch 7 per 3.2 h Membranes with'/2-inch Securock coverboard (optional) Combustible or Cadisle'Polyiso HP -H' or'SecurShield Polyiso'; Hunter z EPDM. PVC and TPO 3 46 Noncombustible Panels'H- Shield' rock- Shield -CG' / 2.0 inch 1 per a h Membranes with ° /e-inch Securock coverboard (optional) a 68 Combustible or Carlisle'Polyiso HP -H' or 'SecurShield Polyiso'; Hunter FAST Adhesive FleeceBACK Membranes Noncombustible Panels'H. Shield' or -H- Shield -CG' / 1.0 inch Combustible or Cadisle'Polyiso HP -H' or'SecurShield Polyiso'; Hunter 7 EPDM, PVC and TPO 5 75 Noncombustible Panels 'H- Shield' rock- Shield -CG' / 2.0 inch 1 per 1.6 h Membranes with'/z - inch Securock coverboard (optional) Combustible or Cadisle'Polyiso HP -H' or'SecurShield Polyso-; Hunter 7 TPO Membranes; 6 720 Noncombustible Panels 'H. Shield' or'H. Shield -CG' / 2.0 inch 1 per 1 It EPDM membranes (vn th noncombustible deck only) Combustible or Carlisle 'Polyiso.HP -H' or'SecurShield Polyso'; Hunter 7 728 Panels 'H-Shield' or'H- Shield / 2.0 inch 1 per 1 h 7 EPDM and TPO Membranes Noncombustible -Inch and With '/2-Inch Securock coverboard (optional) Combustible or Carlisle'Polyiso HP -H' or'SecurShield Polyiso -; Hunter 8 135 Panels eld' ro ck -Shield / 2.0 inch 1 per 1 h z FleeceBACK Membranes Noncombustible with �/z -inch Securock coverboard (optional) '12-inch coverboard 9 141 Combustible or '/7 inch DensDeck Prime 7 per 1 hz FleeceBACK Membranes Noncombustible For SI: 1 inch = 25.4 mm; 1 ft = 0.305 m; 1 psf = 47.88 Pa 'AII foam plastic insulation must be UL- classified foamed plastic for roofing systems, and must be limited to the maximum thickness in accordance with Section 5.4 of this report or the maximum thickness in accordance wAth this table, whichever is less. 7Steel deck must be minimum No. 22 gage galvanized steel (base -metal thickness 0.030 inch (0.76 mm)). Concrete must have a minimum compressive strength (f'.) of 2500 psi. See. Section 5.6 of this report. 3UL Classified EPS may be installed below min. 1- inch -thick Carlisle or Hunter Panels polyisocyanurate insulations (max slope1:12) or below min. V/ inch -thick Carlisle SecurShield HD or Hunter Panels H- Shield HD (max slope 2:12) on noncombustible decks. 4Carlisle SecurShield HD or Hunter Panels H- Shield HD may replace fiberboard and may be used as a coverboard over any insulation. When these two boards are used directly below the Sure -Weld membrane, the slope is limited to '/7:12. 'When application is over existing roofs, documentation of the wind - uplift resistance of the composite roof construction must be submitted to the code official for approval at the time of permit application. For reroofing or recovering, installation must be in accordance with IBC Section 1510, IRC Section R907, BNBC Section 1512, SBC Section 1510 or UBC Appendix to Chapter 15, as applicable.