Loading...
13010144 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 21690 ALCAZAR AVE CONTRACTOR:SOLARCITY t PERMIT NO:13010144 OWNER'S NAME: YOUNG CHARLES C ET AL 3055 CLEARVIEW WAY DATE ISSUED:01292013 OWNER'S PHONE: 6509262669 SAN MATEO,CA 94402 I PHONE NO:(650)638-1028 ❑ LICENSED CONTRACTOR'S DECLARAT7IO� JOB DESCRIPTION: RESIDENTIAL U COMMERCI.ALU License Class C 4(::7 Lie.# &V t 0 `r 24 PANEL ROOF TOP FLUSH-MOUNTED PHOTOVOLTAIC / Contractor D/Q/,C-f 7�/ Date SYSTEM(5.88KW) (�Z�/ (� I hereby alum that I am licensed under the provisions of Ckapll/ter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: I Valuation:$25000 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:35719097.00 Occupancy Type: permit is issued. P ant Y YP APPLVCAJT C%fTIFIfA ION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS ERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS T CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, _ costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,the applicant understands and will comply I �.✓ _ Date:4., with all non-point source regulations per the Cupertino Municipal Code,Section c__.i Zf 9.18. Signature l X-0 Date 1/7 RE-ROOFS: 1 All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for 13 OWNER-BUILDER DECLARATION inspection. I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District 1 performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505,25533,and 25534. Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized agent: /C ��Date• permit is issued. 1 certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affimt that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name AFPLI p 7 CERTIFICATION Lender's Address I certify that I have read this app station an state that the above information is correct.I agree to comply with all city and'county ordinances and state laws relating to building concoction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit,Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date CITY OF CUPERTINO FEE ESTIMATOR—BUILDING DIVISION ADDRESS: 21690 ALCAZAR AVE I DATE: 0112912013 REVIEWED BY: MELISSA 211 APN: 35719 097 I BP#: I `VALUATION: 1$25,000 PERMIT TYPE: Building Permit I PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Duplex PENTAMATION SOLAR-RES USE: p I PERMIT TYPE: A WORK 124 PANEL ROOF TOP FLUSH-MOUNTED PHOTOVOLTAIC SYSTEM (5.88kW) SCOPE -.�4 ..4 £yy.)pf.•• i;b'w,u(�')tx45" + ..`•,' £' `w �':��•`-;: ��vl ..�!'`:?:��t�:'2.4.'S ` -�;b>,y.; is; Ej_":.. e::�': :t�rtpj' Alech. Plan Check 1 I Plumb,Plan Check I I Flee. Plan Check Xfeclr. Perini(Fee: I Plumb. Permit Fee: I F.lec. Pernir Fee. Odier Alec h.Insp. Other Plumb Insp. u Other Elec Insp. Li Alech.hv.ep.Fce. II���JJJ Plumb.hap. Fein- Clec Insp.Fee NOTE:This estimate does not include fees a to to other Departments(La Planning,Public Works,Fire,Sanitary Sewer Otstnct,School District,eta). These fees are based on the orelimina a information available and are only an estimate. Contact the Deot for addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff 711112) FEE QTY/FEE I MISC ITEMS Plan Check Fee: $0.00 = # Alternative Energy System Suppl. PC Fee: 0 Reg. 0 OT 10.0 I hrs $0.00 $219.001 IPHOTOVRES Photovoltaic System 1 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl.Insp.Fee:O Reg: 0 OT [0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Construction Tax: I Administrative Fee: O Work Without Permit? O Yes 0 No $0.00 I I 0 Advanced Planning Fee: $0.00 Select a Non-Residential 0 Travel Documentation Fees: I Building or Structure 0 Strone Motion Fee: 1BSEISMICR $2.50 Select an Administrative Item Blde Stds Commission Fee: 1BCBSC $1.00 $3.50 $219.00 'zj_': x=s ;tTOALF,EEjl $222.50 Revised: 10/01/2012 ALTERNATIVE ENERGY PERMIT APPLICATION A� COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION �, 10300 TORRE AVENUE•CUPERTINO. CA 95014-3255 ^h \ (408)777-3228•FAX(408)777-3333 •buildinafavlcupertino Oro /� CUPERTINO / J�t� �1 ,//�,,Q P0.0JECT ADDRESS r/I J Ar. n n/✓r ,./'I V� " (IJ APN M 35 OWNEA NAME STREETADDREES/SS�;�'? cter/ P• r �r �� I E tAAjB�. FAX CONTACT NAME 1 E- (MAAM STREET ADDRESS ( ICI Y,STATE, ZIP I FAX ❑ OwNER ❑ OWNER BUILDER ❑ OWNER AGENT }1p•CONTRACTOR ❑COMAACTO0.AGEM ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME �`T L ICENSE NUMBER / LICENSE TYPE —q( t..-BUS.LI ,X—�, COMPANY NAME EM .✓A� I 'AX t} &4;1< STREET AODj Ved, Crry p- ,_-/ d�i. ARCHTTECT/ENGTNEER NAME ((TT I LICENSE NUMBER BUS LIC 0 COMPANY NAME E-MAM FAX STREET ADDRESS CRY.STATE,ZIP PHONE USE OF SFD or Duplex ❑ Multi-Family PROJECT M WH OLAND PROTECT IN STRUCTURE. ❑ Commercial URBAN INTERFACE AREA ❑ Yes No FLOOD ZONE ❑ Yes �No SOLAR PANELS I ❑ ELECTRIC VEHICLE CHARGING STATION I Cl SOLAR WATER HEATING ❑ OTFESR _ 11 F RSOLAE PANELS: NUMBEROFPANELSRIMTS: (I KILOWATTS(CCR�05A6ik69NbIq�T ' TOTALVALUA1O'1,, DESCRIPTION OF WORK �% — �ZO JAL L RECEIVED BY' /i� w/Q' By my signature below,I certify to each of the following: am the pr arty owner o authorized agent to act on the property owner's behalf I haves this application and them fortnatlon I have vided is correct. have Tea the Descrlp[1 of Work and verify it 1s accurate. I agree to comply with all applicable local ordinances and state laws relating to b1, Win construction. I authori represent 1 s of Cupertino to enter the above-identified property for pecnon purposes. Signature olApplicanVAgenr. r '�' Date: ia9 ST*PLEMENTAWORMATIONREQUIRED _. ;-♦q� OFMCEUSEONLY OY6R>TB`E-COUNTBR "-. n - = Q STANDARD Q LARGE _ 6_ f ❑ MAJOR PVApp_2011.doc revised 03116111 ABBREVIATIONS ELECTRICAL NOTES INDEX LICENSE JURISDICTION NOTES 1. WHERE ALL TERMINALS OF THE DISCONNECTING PV1 COVER SHEET CA # 888104 A AMPERE MEANS MAY BE ENERGIZED IN THE OPEN PV2 SITE PLAN AC ALTERNATING CURRENT �� �_ C-46, C-10 BLDG BUILDING POSITION, A SIGN WILL BE PROVIDED WARNING PV3 STRUCTURAL VIEWS CUrc T' � CEO��+ OF THE HAZARDS PER ART. 690.17. PV4 STRUCTURAL VIEWS CONIC CONCRETE PV5 UPLIFT CALCULATIONS r F3'mdira c?-_Wt!nent 2. EACH UNGROUNDED CONDUCTOR OF THE , C COMBINER BOX `� JAN 2 9 2013 D DISTRIBUTION PANEL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PV6 THREE LINE DIAGRAM + DC DIRECT CURRENT BY PHASE AND SYSTEM PER ART. 210.5. PV7 ELECTRICAL CALCULATIONS JAN 2 9 3 , 3. A NATIONALLY-RECOGNIZED TESTING PV8 SITE PLAN PLACARD EGC EQUIPMENT GROUNDING CONDUCTOR LABORATORY SHALL LIST ALL EQUIPMENT IN CUTSHEETS ATTACHED (E) EXISTING COMPLIANCE WITH ART. 110.3. 1 e en EMT ELECTRICAL METALLIC TUBING 4. CIRCUITS OVER 250V TO GROUND SHALL F?[ViE;15_DFahC L4•„10E G SOLAR GUARD METER COMPLY WITH ART. 250.97, 250.92 B CUTSHEETS ATTACHED Rcvi;raid By: GALV GALVANIZED ( ) GEC GROUNDING ELECTRODE CONDUCTOR 5. DC CONDUCTORS EITHER DO NOT ENTER PLOT PLANS GND GROUND BUILDING OR ARE RUN IN METALLIC RACEWAYS GENERAL NOTES CHWKW AY HDG HOT DIPPED GALVANIZED OR ENCLOSURES TO THE FIRST ACCESSIBLE DC Installing 24 roof top flish-mounted panels (5.BSkW). I CURRENT DISCONNECTING MEANS PER ART. 690.31(E). Standard breaker tie in (30A) at main panel. Imp CURRENT AT MAX POWER 6. ALL WIRES SHALL BE PROVIDED PATH STRAIN 1. THIS SYSTEM IS GRID-INTERTIED VIA A Inverter and AC disconnect to go in garage. DATE INVS INVERTERS RELIEF AT ALL ENTRY INTO BOXES AS UL-LISTED POWER-CONDITIONING INVERTER. Isc SHORT CIRCUIT CURRENT REQUIRED BY UL LISTING. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. kVA KILOVOLT AMPERE 7. MODULE FRAMES SHALL BE GROUNDED AT THE 3. ALL INVERTERS AND ARRAYS ARE NEGATIVELY Ki WING MffiL kW KILOWATT UL-LISTED LOCATION PROVIDED BY THE GROUNDED. LBW LOAD BEARING WALL MANUFACTURER USING UL LISTED GROUNDING 4• SOLAR MOUNTING FRAMES ARE TO BE GROUNDED DATlNe-� -. MIN MINIMUM HARDWARE. 5. ALL WORK TO BE DONE TO 2010 CALIFORNIA MIR MIRROR 8. ALL EXPOSED METAL PARTS (MODULE FRAMES, BUILDING CODE. (N) NEW RAIL, BOXES, ETC.) SHALL BE GROUNDED USING 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE NEC NATIONAL ELECTRIC CODE UL LISTED LAY-IN LUGS LISTED FOR THE 2006 NATIONAL ELECTRIC CODE AS AMENDED BY NIC NOT IN CONTRACT PURPOSE. POSTS SHALL BE MADE THE 2010 CALIFORNIA ELECTRIC CODE. OFFICE NTS NOT TO SCALE ELECTRICALLY CONTINUOUS WITH ATTACHED OC ON CENTER RAIL. P PANEL BOARD 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE PL PROPERTY LINES BONDED WITH EQUIPMENT GROUND CONDUCTORS PV PHOTOVOLTAIC AND GROUNDED AT THE MAIN ELECTRIC PANEL. COMMUNITY DEVELOPMENT DEPARTMENT PVC POLYVINYL CHLORIDE 10. THE DC GROUNDING ELECTRODE CONDUCTOR VICINITY MAP BUILDING DIVISION-CUPERTINO S SUBPANEL SHALL BE SIZED ACCORDING TO ART. SCH SCHEDULE 250.166(8) & 690.47. ai APPROVED SS STAINLESS STEEL SSp SEE STRUCTURAL DRAWINGS ` _ is set of plans and specifications MUST be kept at the STD STANDARD TESTING CONDITIONS I job site during construction. It is unlawful to make any 4' • chap es or alterations on same,or to deviate SWH SOLAR WATER HEATER _ I , - F I TYP TYPICAL therefrom,without approval from the Building Official. � + � � ,- . LION UNLESS OTHERWISE NOTED - i'ne stamping of this plan and specifications SHALL NO” e _ UPS UNINTERRUP11BLE POWER SUPPLY t be held to permit or to be an approval of the violation V VOLT ' p Vmp VOLTAGE AT MAX POKIER of any provisions of any City Ordinance or State Law. Voc VOLTAGE AT OPEN CIRCUIT W WATT A - 3R NEMA 3R, RAINTIGHT - i..•. ERMIT NO. . BY DATE COMMENTS J� JB-9501188 00 IPTaIg°"� "" "�""° DESCMPP1 DEgar. CONTAINED S— THE r BE INFORMATION R THE x NUIBR ,i BENEFIT O SHALL E E DE USED FOR THE YOUNG, CHARLES YOUNG RESIDENCE SPETE NONFAT LL ANYONE EXCEPT IN IIHOLE R I MARKET.- y[p�� II }� PAR SHALL IT DE DISaDSED E RECIPIENT'S OR IN I REST (24) TRIVIA SOLAR # TSM-245PC05/PA05.18 CUPE IMO, AR AVE 5.88 KW PV Array s Sola PANT m TION, E QUTSTIN THE REaON VAT AaECT MANAGER: uaAlTUC sTSTEIE CUPERTINO CA 95014 aRC,wlunoN, EXCEPT RT CONNECTION rnTn � soss omrvew wxY Say Mateo,CA THE SALE AND USE OF THE RESPECTIVE Comp SleekMount Type C 99402 SOLARCITY EQUIPMENT, TNTHOUT THE WRIIIEN PA11NNr TYPE PAGE NAIL SHEET: ROY. DAIS T:(650)63&1018 F:(6%)638-1029 PERwssN»IOFSaARaTYINC. I PPA (T) SMA # SUNNY BOY SB5000US 6509262669 COVER SHEET PV 1 1/25/2013 (888)-SOQV(765-2489)wm.dad4m . m PITCH: 27 ARRAY PITCH:27 MP1 AZIMUTH:181 ARRAY AZIMUTH: 181 21690 Alcazar Ave MATERIAL Comp Shingle STORY: 1 Story PITCH: 27 ARRAY PITCH:27 MP2 AZIMUTH:270 ARRAY AZIMUTH:270 MATERIAL Comp Shingle STORY: 2 Stories , Front Of House "''�O•�ri �'�!E'�R i 1!qC &.!ildira Cs (tent I t x-, 'A JAS 12 9 3 I � 2oFv,cv; Ei6EJ FOR C MICE--d By:E4 _ I LEGEND O ( Inv; I OPV4 L Q (E) UTILITY METER & WARNING LABEL ---� INVERTER W/ INTEGRATED DC DISCO AC I 5'to PL � & WARNING LABELS `Un-Locl(ea E! fialae) N © DC DISCONNECT & WARNING LABELS ® AC DISCONNECT & WARNING LABELS Q JUNCTION BOX DC COMBINER BOX & WARNING 10'to PL DISTRIBUTION PANEL & WARNING . I Flashing will be painted to O LOAD CENTER & WARNING LABELS match exterior. O DEDICATED PV SYSTEM METER O fl I Total array area: 430 Total roof area: 1500 sq. ft. - CONDUIT RUN ON EXTERIOR MP1 Total array area is 30% of INTERIOR REQUIPMENT roof area. A SITE PLAN N PV3 20'[o PL Scale: 1/&' = 1' W E 0 1' 8' 16 A�—wmmwiil 1 5 JB-9501188 00 � I'maO ` kucup"""° DE IE9� ` CONTAINED L A THE T BE USED F HEREIN im NIAMBER SPETE CONTAINED 91A11 NOT of usm FOR THE YOUNG, CHARLES YOUNG RESIDENCE �• ,,- DENEFlT OF ANYONE EXCEPT SOUJt "INC., IMAWET: MoNAES: 21690 ALCAZAR AVE 5.88 KW PV Array ' S�IaI `j�t �1 NOR STO O IT IME DISCI.DSET IN WHITE aR IN RESI (24) TRINA SOLAR !! TSM-245PC05/PA05. 8 Y , f _ o PART IZ TION, E DEPT IN THE RECIPIENTS PROECT MAMAGM MOLKINO SYSTEM: CUPERTINO CA 95014 `�/f gi ORGANIZATION, EXCEPT IN CONNECTION N1T11 � THE SALE AND USE OF THE RESPEC11YE Comp SleekMount Type Ci 30s5 amrview'AbY San Ma[co,CA SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE, PACE NNE: 941: REV. DATE T:(IiSO)63&1D2WF(65o)63&1029 PEANSSION w so(ARaTY INC. PPq ( SMA # SUNNY BOY SB5000US 6509262669 SITE PLAN PV 2 1/25/2013 (888)-SOL<Y/664489)w -%ITuy. (E) 2x8 RAFTER ® 24" O.C. x12 SL E 2 RIDGE BOARD \ (E) 2x6 SincM (E) LBW L2-- (E) 2x8 RAFTERS -6 3,-7• s-3• @ 24" SPACING (E) LBW RAFTER: 2x8 SUPPORT: 2x8, 202, 2x6 FRONT VIEW OF MP1 MAX SPAN: 8'-7" OB SCALE: 1/2" = 1' OA SIDE VIEW OF MP1 SCALE: 1/4" = 1' � ^. j,, Jiir.�I?..�artment qC PV MODULE �". E},!' o k' BOLT WITH LOCK & I INSTALLATION ORDER , :; '' FENDER WASHERS '';! "' ^ �' J , Ell LOCATE RAFTER, MARK HOLE ' '""I � �� Z " O13 ZEP LEVELING FOOT LOCATION, ANODE RILL PILOT F?CN(EStECFCn) 0 on ZEP ARRAY SKIRT (6) v,-li;�°L:..,yCE (4) I I (2)I POLYURETHANE SEALANT. I Rca,evr��3y:SEAL PILOT HOLE WITH ZEP COMP MOUNT C 1 ZEP FLASHING C (3) INSERT FLASHING. CI (E) COMP. SHINGLE O (4)I PLACE MOUNT. (E) ROOF DECKING U (2) l V (5)I INSTALL LAG BOLT WITH j LAG BOLT WITH (5) I C SEALING WASHER. SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES ( ) INSTALL LEVELING FOOT WITH (E) RAFTER 6 BOLT & WASHERS. S1 STANDOFF Scale: 1 1/2" = 1' J B-9 501188 0 0 I PROMISE O11ER ANQ y 4mtm BESCII DESI CONTAINED L—THE T BE USED F HEREIN JOB NIArBER SPETE ,,•,_• CONTAINED sI1uE NOT BE usEO FOR THE YOUNG, CHARLES YOUNG RESIDENCE .-,,,. BENEFIT OF ANYONE E%CFPT S(xARCItt INC., yAg�T: YOpAES: I�1 NOR SHALL H rS OUTSIDE T IN WNC/.E T' IN I RESI (24) TRINA SOLAR s TSM-245PCO5/PAO5. 21690 ALCAZAR AVE 5.88 KW PV Array So�ar�it PART TO OTHERS QU79DE THE REGIMENTS PROJECT MANAGER MOUNING 5y51E1E CUPERTINO CA 95014 RE SALE AND USE IN CONNECTION WITH 3055 aa3rvew way San natm,ca TEE SALE AND usE of THE RESPECnvE I Comp SleekMount Type C 9,.w2 SCLARCITY EQUIPMENT, M1HOUT THE WRITTEN PAYMENT TYPE N�761 PACE REV: O"R' T:(650)638-1078 F:(650)63B-1029 PEINWION OF SOLARCITY INC. I PPA lT1 SMA # SUNNY BOY SB5000US 6509262669 STRUCTURAL VIEWS PV 3 1/25/2013 (888)-SOL-Q1Y(765-2489)w .wladty.m (E) 2x6 RAFTER ® 24" O.C. S2 (E) 2x8 RIDGE BOARD (E) 2x6 '(E) 0'-1° 3"'(E)� (E) 2x6 CEILING (E) 2x6 RAFTERS JOIST ® 24" O.C. @ 24 SPACING LBW LBW RAFTER: 2x6 SUPPORT: 26, 2x8 FRONT VIEW OF MP2 MAX SPAN: 9'-1° OD SCALE: 1/2" = 1' C SIDE VIEW OF MP2 SCALE: 1/4" = 1' PV MODULE BOLT WITH LOCK & INSTALLATION ORDER FENDER WASHERS ;~ &-gilding t LOCATE RAFTER, MARK HOLE r , ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT Ivi rig -' r ZEP ARRAY SKIRT (6) I HOLE. ` (4) I I (2)I SEAL PILOT HOLE WITH POLYURETHANE SEALANT. FtE-ViE-IXEDFORC0- - PLIANC= ZEP COMP MOUNT C _ ZEP FLASHING C (3) (3)I INSERT FLASHING. By: (E) COMP. SHINGLE rLOWEST O (4) PLACE MOUNT. 1(E) ROOF DECKING (2) (5) INSTALL LAG BOLT WITH LAG BOLT WITH (5) SEATING WASHER. SEALING WASHER ULE SUBSEQUENT MODULES C I INSTALL LEVELING FOOT WITH (E) RAFTER (6) BOLT & WASHERS. STANDOFF S2 Scale: 1 1/2" = 1' CONFIDENTIAL- THE IWORMATION HEREIN I .re NUIHI)ER J B-9501188 0� I"�o)NHDE 'JL6 `"'e'°�° DESawTm 0ESIM ������ CONTAINED EM 0 SHAU.O NOT BE usm FOR THE YOUNG, CHARLES YOUNG RESIDENCE SPETE , •� BFNEFTf OF AN ONE IXCEPT SOIARCnY INC, YAfAOL yppD(Ey+, II �/1 NOR SHALL IT BE D6CLOSm IN rAHa.E aR IN I REST (24) TRINA SOLAR # TSM-245PC05/PA05.18 21690 ALCAZAR AVE 5.88 KW PV Array �SolarCi o PART TDOONmso RECIPIENT'S I�cTmomm HOSTxG6,s� CUPERTINO, CA 95014 366Ba®MewWaYSanMaho,CA ORGANIZATION, IXfT:PT IN CONNECTION WHH TIE SALE AND usE aP THE RESPECnYE Comp SleekMount Type C SOLARCITY EQUIPMENT, RTIHOUT THE WRITTEN PAYMENT HYPE PILE NAME:- STEED REY. DALE: PERMISSION(>F soHARarr INC. 1 PPA (T) SMA # SUNNY BOY SB5000US 6509262669 STRUCTURAL VIEWS PV 4 1/25/2013 (688}SOLOQiY(7652%9)w .soarory.mm UPLIFT CALCULATIONS 1/28/2013 SolarCity SleekMountTM Verslon#4.1 Project Informatlon System&MP Information Symbol Value Related Info Occupancy Category 11 PV System Type SolarCity SleekMount•" PV Module Trina Solar TSM-245PC Total Number of Modules 24 Roofing Material Comp Roof Number of Layers(Comp Roofs Only) 1 Tile Reveal(Tile Roofs Only) NA Roof Slope 272 Spanning Vents? No PV Module Orientation Landscape and Portrait Pv Module Length 3.3 ft PV Module Width 5.4 it Attachment Type Comp Mount Type C Total Square Feet of Array 423 sf Wind Design Criteria ,WAF AW*, Wind Desiqn Code ASCE 7.0�P4rbalfy/FG11 8ido5ed M ad Exposure Category B Section 6.5.6.3 Basic wind Speed V 85 mph Fig.6-1/1-ocal Data Least Horizontal Dimension of Building LHDwp'' Roof style Gable Roof Fig.6.11B/C/D-14A18 1 Mean Roof Heiqht h 15 ft Secbon 6.2 ^'t ✓ Bulldif:j`1°7af!fnent 99Yd Zone InteriorI Edge Corner Wind " nd Pressure Up(psf) p(Up) -10.0 -17.4 -27.0 - +%'� � AN, 2 9 013 Wind Pressure Down(psf) p(down) 10.0 10.0 10.0 f?Cb'iEli�'EDr�Ot�h:. " uiF'L'A^lCE Snow Design Criteria Coefficients Rcv„wod By: Ground Snow Load I pg I I I Table 7-1/Local Data Comp Allowable Attachment Sidcng(idles)and Tributary Ara (sf) Interior Edge Corner Maxmum Allowed Foot Spacing Landscape 72" 72" 72" Maximum Allowed Cantilever Landscape 24" 24" 24" Max Standoff Tributary Area TribCL 20 sf 20 sf 20 sf PV Assembly Dead Load WPV 3 psf 3 psf 3 psf DLPV PCL 59 Ibs 59lbs 59lbs WLUP- 0.6 DLPV TCL 160 Ibs -304 Ibs -492 Ibs Attachment Uplift Capacity Tallow 637 Ibs 637 Ibs 637 Ibs TCL/Tallow DCRLand 25.1% 47.7% 77.2% J B-9501188 00 I PREYSE oWrTE " ` DESOWTM DESOW. "' CONFIDENTIAL AI THE T BE USED F HEREIN im MNffR: SPETE _ CONTAINED SHALL NOT BE USED FOR THE YOUNG, CHARLES YOUNG RESIDENCE -�-SolarCity NOR SH D<ANYONE CLOSED IN MOLE INC.. MARKET YODIAES 21690 ALCAZAR AVE 5.88 KW PV Array �� n NOR SHAll IT ff DISCLOSED IN yMOIf OR IN RES 24) TRNA SOLAR N TSM-245PC05/PA05. 8 f�/ PART TO OTHERS OUTSIDE IN 7HE CONNECTION WT PROJECT YuTAax MOU01 c sysu CUPERTINO, CA 95014 ORGANIZATION, EXCEPT IN CONNECnON X1TH THE SALE AND USE W THE NESPECRYE Comp SleekMount Type C 3055 oavry way 5a"Natw,CA SOIARCITY EQUIPMENT, WITHOUT THE WRITTEN PAWa11i TYPE WIACRiFA: RAGE NAME: SRO., REV. DATE: T:(65D)638-10 8�Z(650)63&]079 P�""'�0 OF S0A"p Y INC. PPA (1) SMA # SUNNY BOY SB5000US 1 6509262669 UPLIFT CALCULATIONS PV 5 1/25/2013 case>-SOLQTY(765-29 )wHw.Sdatlq.o GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) 18 GEC TO (N) GROUND ROD (E) 200A MAIN SERVICE PANEL Inv 1: DC Negatively Grounded INV 1 -(1)su 1 SINNI'eor SBS8Ba13 IABa:" -U+) imes r 24M 2a+w PIC Ok a F. CA � 868104 AT PANEL NTTH IRREVERSIBLE CRIMP Multiple Main Breakers Fewer than 6 M"`Ir 'z�a°'° C-46, C-10 P ( ) Voc: 37.3 Panel Number.Challenger 200A INV 2 Vpmax:30.7 Meter Number.1006679680 *MODULE CURRENT RATINGS ARE SHORN AS Isc AND Imp IN Underground Service Entrance INV 3 THE DC STRINGS IDENTIFIER OF THE SINGLE LINE DIAGRAM. MAIN SERVICE PANEL Use Combined Terminal CUTLER-HAMMER Inverter 1 Disconnect n SMA SUNNY BOY SB5000US (E)LOADS B I I U IGFP/GFCI A WE m I) I N r -- IAnn9()IX 12 On MP1 2 30A/2P rG �+ 1 hn9ls)O 12 On MPI 03 II .� " I 1®r-��L----�--------------------------- -- ----- -- 1 I 1 N I EGCIGEC I Zt5 ---�cEC --1 TO 120/z4OV SINGLE PHASE UTILITY SERVICE i Widirg Ds!wir!ment �i�° J,-";�1 2 9 013 R'1=ViEWED i=OR C - IPBAMCE Rcvlcw3d By: COI -(1)omFS-xwex m¢w we,Inaem■ruzn R �-(1)amm-xN�[n/oarlul® AC 4 I—(1)eB%d 1�++ DC a.d�30A/2P,z SPxxs !�J ol. t 3or.zbv:.xm-F�.w,Imu sl - ua .xuu» (1)aww R*6/B'x w,COW -(1)amm-xNrn DGOJa6 (2) 11114 ACSonn.3Pwt aa.dMa6d I�E 3oA ce.a uHr(BS) N-P+ANB,Sun.tla.,wbl.a O�TT(1)AM P0.VIIN-2.Black (2)ANO p%USE-2ABW-2.Wadi Voc 447.6 VDC Isc -16.94 ADC EE�-(4)AN P06 USE-zAwr-2,Bit* Voc 447.6 VDC Lsc =8.47 ADC L4r(1)AW P4 IR■1-Z R&I O (1)AK Pl SdN B.app. Ecc Vmp =368.4 VDC Imp=15.96 ADC O kSF(1)AF P,SdM B.Co ECC Vmp 368.4 VDC Imp=7.98 ADC SELL(I)"ea P0.vw-2 waa minor Vmp =240 VAC imp=20.8 AAC ......`V..(1)ra.Nxn.3jj'D?...... ..... ........ ........ ... ........... ®® .. ... ............. .......-(1)Awo Pi 1B.R1ti2.pwI... ..TzaAxp. -q)elan ?/q m ... ......... J B-9501188 00 PAUISE OMRt uu cumt o DFSCRP,uE DF961e `"'_ CONTAINED L- THE T BE USED HEREIN JOB Hume SPETE ='OOH ■ CONTAINED SHALL NOT BE USED FOR THE YOUNG, CHARLES YOUNG RESIDENCE BENEFIT OF ANYONE EXCEPT SOLARCITY INC.. WJW-. MODULES -001 NOR SHALL IT BE DISCLOSED T E EOPIE T' IN I RESI (24) TRINA SOLAR # TSM-245PCO5/PAO5.�a 21690 ALCAZAR AVE 5.88 KW PV Array �� SularCi , PART 1oMON.EXCEPT ou19IN CONNECTION PROTECTMAMAGM MaunxcsISE1E CUPERTINO, CA 95014 ptE SALE A N, OF IN E RESPECTIVE I V w11H 3055 Oearvkw Way San Mateo,G THE SALE AND USE of THE RESPECTIVE Comp SleekMount Type C 902 SOURCJTM EWIPMENT, N17HWT THE WRITTEN PAYMENT 714E PACE NAME �' DATE 7:(650)63&1028 F:(650)63&1029 PERA1SSIpIT a soLARaTY INC. I PPA (" 1)INYERTM # SUNNY BOY SB5000US 6509262669 THREE LINE DIAGRAM PV 6 1/25/2013 (888)-SOLQTY(765-2489)wv -%Iaoty.mm 1. Conductor Sizina aer Art 690.8(6)(1) ELECTRICAL CALCULATIONS a. Conductor must have 30 deg. C ampacity >= 125 of continuous current per Art 215.2(A)(1). Module: 24 TRINA SOLAR#TSM-24513005 222.9 Inv Paver WPTC Voltage Drop Calculations Version 5_8.0 Inverter 1: 1 SMA SB-5000US(24OV) 0.955 5000 5108.87 Vdrop= (Imo) ' (2'Lenqthl'(Resistance) / (Vmp) b. Conductor must have (after corrections for conditions of use) >= Module: Imp fA) I Max.Length(it) wire I continuous current ,Table 310.15(B)(16)- Inverter 2: String: 7.98 30 AWG_10 at Max Ave Hi:77 degF P Module: Vdrop= (7.98 •W {O.0 1 hms) / 340.4928 0.17 Inverter 3: Branch: 1 15.96 I 50 f AWG_10 I at Max Ave Hi:77 degF c. Evaluate conductor temperature of terminations per 110.14(0). Module: Vdrop= ( 15.96 -100 '0.0012gjhms) / 340.4928 0.58 Ampacity of wire derated for conditions of termination must be >= Inverter 4: Total voltaae drop in DC conductors= 0.76 continuous current*1.25. All string terminations are rated at 90' C. Inverter. 1 15.96 I is J 2Ohms � 240V Vdrop= ( 15.96 •3U •U.U1 Ohms) / 240 V 0.2394 ------------------------------------------ Total: 24 Modules Total Inv Pwc1 5000 5108.87 I PTC Combinedl 0 I 0 I 1 at 240V 2. OCP Sizina Der Art 690.8(B)(1) Photovoltaic Module Electrical Specifications: Total STC:l 5880 Vdrop= (0 •0 Ohms) I 240 V 0 a. Round up to next size per Art 240.4(8) Vac: 37.3 V deg F deg C Vmp: 30.7 •V Record Low Temp:1 16 0 Total voltage drop in AC conductors= 0.24 3. Conductor Sizina Der Art 690.8(8)(1) Isc: 8.47 A Max Average Hi Temp:177 25 Total voltage drop in AC and DCconductors= 0.99 a. Conductor must have 30 deg. C ampacity >= 125% of continuous Imp: 7.98 A Record Hi Temp:185 30 current per Art 215.2(A)(1). Tvoc: -0.11532 •V/degC Tisc: 4.185 mA/degC ITpq`1 b. Conductor must have (after corrections for conditions of use) >-- I String Tvpe A and 2 Combined Shims Type A Voc Correction Method: Manuf Tvoc data Brands Circuit Tvoe A Per series string Voc Correction Factor. a EPW IdO D Pplitment continuous current per Table 310.15(8)(16). I TYPE_A_INV z strings per branch length: I 12 TRINA SOLAR#TSM 245PC05 Inverter Min Vdc Input 250 Min Vmp at Max Temp: 340.49 JAN c. Evaluate conductor temperature at terminations per Art 110.14(C). Voc= 447.6 Max Voc at Min Temp: 482.2 Voc 447.6 V ) 9 13 Ampacity of wire derated for conditions of termination must be >= Vmp= 368.4 Inverter Max Vdc Input 600 Vmp= 368.4 v m continuous current*1.25. All branch terminations are rated at 75' C Is 6.47 Isc= 16.94 A Imp= 7.96 Max String Size: 14 Imp= 15.96 ,A FEMElALED FM CO- 4: CE min. 1-way wire length: 30 __________________________________________ Ioont= 10.59 Art 690.8(A)(1) Ioont= 21.18 A 690.8(AIII) 4. OCP Sizing 1.a Try AWG-10 IUSE-2/RHW-2 at 90 deg C:Table 310.16 3.a Try AWG_30 THWN- gl=C b'� Icont 1.25=(Amps) 26.47 a. Round up to next size per Art 240.4(6) lcont'1.25=(Amps) I 13.23 I 30 deg C ampacity= 40 ------------------------------------------ 30 deg C ampacity= 40 3.6 Icons=(Amps) 21.18 �. Conductor Sizina Der Art 690.8fB)(1) 1b lcont-(Amps) 10.59 I Start ampacily 40 a. Conductor must have 30 deg. C ampacity >= 1257 of continuous Start ampacity N28.4 Temperature derate(%=F) 0.82 current per Alt 215.2(A)(1). Temperature derete(%=F) Conduit fill derate(°/� 1 Conduit fill derale(% Derated ampacity 32.8 1 b. Conductor must have (after corrections for conditions of use) >= Derated ampacity 1 3.c Term 1 Term 2 continuous current per Table 310.15(6)(16). 1.c Temptable 75degC 75degC Icont'1.25=(Amps) 1 13.23 I lmnt'1.25=(Amps) 26.47 26.47 L- c. Evaluate conductor temperature at terminations per Art 110.14(0). Ampacity 0 Ampacity, 35 351 I I Ampacity of wire derated for conditions of termination must be >= I2 Icont'1.25=(Amps) 1 13.23 I 3.d OCP Size 1 301 continuous current*1.25. All inverter output terminations are rated at OCP Size= 1 15 I combined inverter Output 75' C. I Inverter TYDe A Output Service Voltage= ------------------------------------------- I SMA SB-SOOOUS(240V) 1 1 way wire length: 10 ft Total Inverter Power- 1 way wire length= 0Icont=#of inverters'max inverter current Art 690.8(A)(1) 6. OCP Sizina Icont= I 20.81A Art 690.8(A)(1) Icont=(Amps) a. Round up to next size per Art 240.4(B) 4 Icont'1.25=(Amps) 26 Art 690.8(6)(1) 6 Ioont'1.25=(Amps) u Art 690.8(6)(1) OCP Size= 30 Art 240BW OCP size= I I Art 240.6(A) 7. Conductor Sizina Der Art 690.8(B)(1) 5.a Try I AWG_10 THWN-2 at 90 deg C:Table 310.16 7.a Try I THWN-2 at 90 deg C:Table 310.16 a. Conductor must have 30 deg. C ampacity >-- 125% of continuous Icons' Cam (Amps) 26 Icons' Cam (Amps) 9 p y 30 deg Campacity= 40 1 30 deg Campacity= 1 current per Art 215.2(A)(1). 5.b Icom=(Amps) 20.8 7.b Icont=(Amps) Start ampacity 40 Start ampacity b. Conductor must have (after corrections for conditions of use) >= Temperature derate(%=F) 0.91 Temperature derate(W) continuous current per Table 310.15(B)(16). Conduit fill derete(°i°=t) 1 Conduit fill derate(°i° Demted ampacity 36A 1 Derated ampacity 1 c. Evaluate conductor temperature at terminations per Art 110.14(C). 5.c lcont'1.25=(Amps) 26 7.c lcont*1.25=(Amps) Ampacity of wire derated for conditions of termination must be >= Ampacity' 35 Ampacity continuous current*1.25. All inverter output terminations are rated at 75' C min. I I JB-9501188 00 "° �" DESaWTM DESM `"' CONFIDENTIAL- THE INFORMATION HYMN d°B MABER ���64 CONTAINED SHALL NOT BE USED FOR THE YOUNG, CHARLES YOUNG RESIDENCE SPETE �. BENEFIT OF ANYONE EXCEPT SO ARCI Y INC., MAwL MODM I '`�JJ NOR SHALL IT BE DISCLOSED IN MHOLE OR IN REST (24) TRINA SOLAR # TSM-245PC05/PA05.18 21690 ALCAZAR AVE 5.88 KW PV Array .SD�a�� a PART To OTHERS OUTSIDE THE RECIPIENTS FRDECTIIANACII[ NDAMSISIEIE CUPERTIN0 ORGANIZATION, EXCEPT IN CONNECTION WITH I CA 95014 THE SALE AND USE OF THE RESPECTIVE Camp SleekMount Type C sassa��sarr>a�,cn SUTAROTY EQUIPMENT, NITHWT THE MRITIEN PAS TYPE PAO NAIE 51EET: RE15 DAIS T:(650)638-1028 F:(650)63&1029 PERMISSION OF saARCITY INC. PPA (1° ) SMA # SUNNY BOY SB5000US 6509262669 ELECTRICAL CALCULATIONS PV 7 1/25/2013 (888)-BOLQrY(765-2489)w .wWcty.M CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 21690 Alcazar Ave INVERTER & AC DISCONNECT am )HOTOVOLTAIC )1 ROOF X X U71UTY SERVICE Y(`.- F3::iIOIr. I?snarmem ' r 2013 PHOTOVOLTAIC BACK-FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS F?EM KEID FOR WjpL!ANC'E Rcdicvd�d�y: A/C DISCONNECT PER NEC 690.17 - OPERATING VOLTAGE = 240V MAX CURRENT = 20.83 A JB-9501188 00 PROM BUM u" `�r"ro �T� DEW CONTAINEDAL—THE IKORIIAED F HEREIN AB HIA6ER SPETE CONTAINED SIiAEE NOT RE usm FOR THE YOUNG, CHARLES YOUNG RESIDENCE .• , BENEHT OE ANYONE EXCEPT SIXARCNY INC.. YAMQT: MODIAES. NCR SHALL H BE OUTSIDE THE RECIPIENT'S T' IN I RESI (24) TRINA SOLAR # TSM-245PC05/PA05. 8 21690 ALCAZAR AVE 5.88 KW PV Array �� + _ SO�a�j� , PART m OTHERS CU7510E THE CONNECTION WITH PROJECT MANAGER MOUNTING SYSTEM: CUPERTINO, CA 95014 ojj RE SALE AND EXCEPT R!CONNECCTI MITH 3055 Cleaniew Way San Mateo,CA TOE SAES AND USE of THE RESPECTIVE Comp SleekMount Type C PACE NAME SHEET: REV BATE 9W2 SOLARCEIY EQUIPMENT, MTHOUT THE NRn1EN PAS TYPE: 1/25/2013 �T:(650)638-1028 F:(650)638-1029 PERMISSION of SOIARCITY INC. PPA SMA # SUNNY BOY SB5000US 6509262669 SITE PLAN PLACARD PV 8 )-SOLD (765-2989)w .sdaraty.00m PHOTOVOLTAIC DC DISCONNECT Label Location: Label Location: WARNING! ELECTRIC SHOCK HAZARD! Solar Per Code: voc v 690.53, NEC 690.53 90 ••■ Vm V WARNING- Electric Shock Hazard Isc A DO NOT TOUCW TERMINALS ��a Im�,p�'+ A Terminals on both line and Load sides •,,'Jo�al li�ty heel soL clTr may be energlied in the Open Position SOIAFCITY COM Label • • Label WARNING Dual Power Sources DC DISCONNECT ■ Label Location: Second source is photovoltaic system DO NOT TOUCH PERMINALS Terminals on both line and Load sides may be energ zi ed in the Open Position WARNING Electric Shock Hazard No user serviceable parts inside SOLARMODULES ARE EXPOSED TO SUNLIGHT Contact authorized servicer for assistance WARNING! Label Location:Label Location: INVERTER OUTPUT CONNECTION.DO NOT WARNING! ELECTRIC SHOCK HAZARD! RELOCATE THIS OVERCURRENT DEVICE. DO NOT TOUCH TEFMINALS TERMINALS ON BOTH THE LINE ANC LOAD SIDE MAY BE ENERG ZED Label P A PHOTO`JOLTAIC AC DISCONNECT - ■ OPERATING AC VOLTAGE v WARNING! ELECTRIC SHOCK HAZARD! Per Code: ,. '� SolarCity OPERATING AC VOLTAGE V :�• level soLcnr e01APCITY.COM MAXIMUM OPERATING CURRENT A �" (8887 SOL-CITY • `�, Label Location: '��SolarCity SOLAPCITY.COM � PV COMBINER BOX WARNING: � 1 VANCE (CB) Rcviow3d By: ELECTRIC SHOCK HAZARD Disconnect •• • • • Distribution• . :• CAUTION: SOLAR CIRCUIT ■ ■ DC Disconnect Interior • . (INV): Inverter With Integrated DC Disconnect •.. Center (M): Utility Meter •• Point CONFIDENTIAL - THE INFORMATION HERON CONTAINED SHALL NOT BE USED FOR Cle�Way TK BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �n ma�,CA W02 38 028 R(6%)638�1029 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION. Labels T'(650)S6 EXCEPT IN CONNECTION SOLARCITY EQUIPMENT, WITHOUT THE WRITEN PERMISSION OF SOLARCITY INC. SolarCityl • S y Bey soaDlls wmy Boy 600005 Sumy Bay 70 s Sunny Bey BooDUs T«Inical ama ]9CYK mVK DIYK ]IBVK mVK D)VK 9gVK mVK 'll7VK mYK DIVK noW�DC) ammerldedwpa. 625ow ]sooty 875ow la000w 5300W 6350W 740OW 8600W M DCwlbge 600V 600V 600V 600V DC nominal wltage 310V 310V 310V 345V MPPvdagemrge 250V-480V 250V-480V 2 V-AWV 303V-480V Min.DC wlbge/stan.dbge 250V/300V 250V/300V 250V/3WV 300V/365V Maw.inpec:man/pr ahirg jdXd'emnr•cl) 21A/MA 25A/20A 30A/20A 30A/MA i° 36AO.Inn.dhmliml 36AOcom1hinodlemliml 36AO<ombi dbmlnol 36AO.W seminal WnAxtr of MW hocken/ I/4 IX dlKOnnenl ) hued strings per MIT nmiter y OuIvA IACI want AC nen:inol power SOOO W 6000 W 7000 W 7680 W BOOO W Max AC apparent power 5000 VA 6000VA 7000 VA 8000VA a Nominal ACwbage/odi:utable 29ev/• MV/0 2 V/• "We mV/• 2 V/• MV/0 MV/* WV/0 mV/e my/e 0 AC-IMge wart• IO-TAV 211.261V LI.M1 M-MA 211..y L4.ffil IB]-LVV 211-.%f . M 211.WV 2u.' V AC grid het ,,mnte 60 H,59.3-605 H2 WHn 59.3-MIS H2 60 H;59.3-605 HZ 60 H,59.3-603 Hz Moz ovlpal cwmnl 24A 21A IBA 29A 25A 22A 34A WA 25A 32A $ Poem,Imw(cos 91 1 1 1 1 M. .duclws/concoction phew 1/2 1/2 1/1 1/2 1/2 1/1 1/2 1/2 1/1 1/2 1/1 Meeman'ra <A% <A% <4% U% Eflkianq 2j Mm.eAkbnq 967% 96.8% 968% 96.9% 96.8% 97.0% W..1% %.9% 97.0% 96.3% 96S% S CEC eRiciwry 953% 953% 95S% 955% 953% 960% 955% 960% 96.0% 960% 960% P PA �•. P.otacrion dwbes DC reaneppbiry Pmbcfon • • • • # AClhondmuYpnobtlion • • • • 6 Gakar:mlN i,dotad/alyde s.nYbm no:libr:'rg une •/- •/- •/- •% A ' Praleceon class/oreroW.yp cobgary I/III I/IA I/III I/IB y, .. �,. General darn 11 •t Dim nm IW/H/DI in mm lint 470/615/2401185/24/91 DC Dh wnect dmemiaru(W/H/DI in mm(in) 187/297/1% 17/12/75) PaCOt,dimemions IW/H/DI in mm(in] 3"/580/8W (16/23/31,5) DCDhmonnpuc6V nvwcnzfW/H/DIHmmW 370/240/280 (15/9/III Wages/DC DIKOnnect wagN 64kg (1411bI/3.5kg (81b1 6640(1451b)/3.Skg(6IbI -�,. �., Pocking xegM/DC Dinm:rM parking xdgla 67kg (1471b)/4kg (91b) 69kg 11 52 161/4kg 191b) • v i•1"E,w, Operaing hempen N-nng IVµw 4 -25-C..-45•C (-13'P-.,II3-F) b Narr emission(Npi<a11 44 dB(AI AS dBIA) 46 dB(A1 49 dB(AI a w 1c•(t,. Inbmal canwmpeon at night 0.1 w 0.1 W - -.0.1 W -011�y,{;�s�� •d R�/� .�+p-:•`'' 'v hA, Tq-6w IF t,n-6rme• IF handwme; A' JFAOn"tner Ik4epg0Tlar )to 4 Wdl:p coKept Opfi ml OpiC l / 's:OPnCod " ,CIp6Cm1 f Elxlrao'cs prob .mnrg/.—fin-area NEMA 3R/NEMA 3R NEMA 3R/NEMA 3R t� V" j3R/NEMA 3R tgiAUB;Ip�MA�Q!Aftment Feaons 664!!:, Di,I,.ew Brie/gr,hk •/- •/- 4_ai '.�! •/ . ht1 •% d Intadocn-RUES Shntoob 0/0 0/ "'y l 0/4-, J O 7 4 , 1N. 2 w 201 // Wanamy 10/15/20Yoan, */c/o y0/0 • o 0 0 0 g CaMRk..and pennh 1.ovdlnble anm9aeel UII]41,UII99B,IEEE 1547,FCC PWryIS�(`Cbu A B III.kC U2..2 Nr I A. NOTE US inwmn,hip with gm Eds. 1lL ViEIi 1r L�.,Ji t,/�'l C4 1 (2'��cc Dab a1 notninol<avdROns �:A N.-C C •standard fnoNro 00ptinal 6owro -Nd woibbls (2GJ1� rya DJJ TYpe d-let SB 5000US SB 6000115 �e ____....._._..._........__.............. Accessories ------'?EBdxy<um SUNNY BOY 7000U5 k __._........_...___.........._._....: I t 98 4LB5'sibe eod SMI R®2 : �..-•. .._•.-•-.._.. � � IBSIISMSMLNI B1RIM/NR B 96 ..._...-.._........._. .._..... -M1 i w / i 92 { � Po '� ii oC eken.naHw 3=•d6..V9baNe4 V. Be i I 1 t• fi � mHeoswltbl p - v -2I9v6C IY 9 ...... -IMVm v�M `i ggg B6 V• j i I 1000 S9W 3000 4000 SOOD e9go 7000 A Toll Free+1 888 4 SMA USA •US Pamm 0 57 3 5 2 5198 1 w .SMA-Americo.com SMA America,LLC mono multi solutions TfIfK]mount II FOR PITCHED ROOF TSM-PC05/ PA05.18 mono multi solutions ELECTRICAL DATA®STC obi TSM.bp TSW235 7SW240 15A1-x8.5 DIMENSIONS OF PV MODULE TSM-PC05/PADS.18 PC/PADS.18 PC/PAOS.18 PC/PADS.18 PC/PAOS.IB PC/PAOS.18 Peon Power Wotth-P,U(W p? xx5 230 xis 26(l 215 Po Tdermce-Pu 01-3 D 13 D.3 0/.3 , o YEAR 6agm P.eVdape-V✓TV) AA A.8 0.1 01 3017 Tr i na m o u n t I I PRODUCT WARRANTY FOR MODULE $ PoWiter °"'"I'^IN 7'66 x'xx Tsl xs° z9e TriLasclar AND MOUNTING SYSTEM open Circuit VoIIaRa-voo IV) M'9 3710 37.1 37.2 373 Streit Clout CMreri(A) 11<0 826 "1 9.37 8.17 FOR PITCHED ROOF 5X - Monte El6tla¢y DmW 117 11.1 114 14.7 150 FASTER TO INSTALL AL 3a vobm m5lantivtl lmlcmUXOnaSIC M Mnu M1L5.InaEbnCe1W'JW/m'.<el TemppelNe x5Y1. i ULTRA LOW ELECTRICAL DATA 0 NOR M 225 TSM-= TSM-235 MM-210 TSM-265 PCRA05.18 PC/PA05.18 PC/PA05.18 PC/PA05,18 PC/PA05.18 RESISTANCE Mere.Power .Vre 161 168 17. 175 179 ffi Momlvn P.vdapa lvl x619 2L1 Z7.1 xx.I xxB YVb GROUND BOND CONNECTION ,_ Mmllmpm Powelcunem lAl 61x 6.x0 627 dax del IOX BETTER THAN UL MINIMUM CRITERIA @ Open Cimdl Voltage lvj MA 339 310 31.1 31.2 Strorl Cicurl Cr,-nt JA) 662 6.a 670 675 6.83 / 1 �_ �alinuJ,anee.nl�3W/m'.ATCbnl iempIXalNe YJC.WFG5pee01M/Y Back Yew MECHANICAL DATA Solar Cele MWkrystaElre 156.156mm is rrehe51 Cel arientaton 60 cars 16.101 Module dinenuon 16W•992.60mm(64,9S-39 05,1 57 ncH j Weight 20.3Rg ILIA DI Goss High lramparan ysplar glass 3.xmm 10.13 i.1HoHI Frmo AnoKeG air,hh ncloy l"Box IP 65 mled AA CCDks/C.Oor Pholevdloic Teohobpy Cable l.Ormr I0.0J6 nciNefl. I IOOmrn(113 lncheR).MU/HI I-V CURVES OF PV MODULE ISW230?C05/lr D.18 B "oe"We" TEMPERATURE RATINGS �y ! li 7 �'M, Nomnd Opereerp Cefi 16°C I:xC� L' I r pR� <6 elm, _. 1111.. Temperature lNCCTI rte. `5{� O rlMJI'�'r1w'R�.F9�'^.y Tenperdve Coelfierenl d P-, -0,03INA t ; rJ"TIIE:It !J��11::11ent Teniverdure Coefficient d Voc "o3ml-i- f iernperdVe Coefficient.1 lx 0.06 ~ SUITABLE FOR -. 2 13 COMBINING PV MODULE EXPERTISE WITH A HIGHLY °'D- 10e x0' 30 .a. MAXIMUM RATINGS / 1•EEr3 r. ® INNOVATIVE MOUNTING SYSTEM SOLUTION. Vdbg.m Maxi r?tb I ,� J( CnC tiZ,gyCE Operanano�lemperplure -10-195`C I COMPOSITION SHINGLE Trina Solar is introducing Trinamount-the fastest,easiest and least T d B , m „m svnom vonapp 1 11.`DCIPCI a.v"o j/. expensive way to mount PV modules onto residential and commercial Dcwu �y rooftops.With a series of drop-in and quarter-tum connections on a Ma.Sole,1,Rmmg t5A $ ® TRAPEZOIDAL METAL specialized module frame,this mounting solution installs up to 5 times CERTIFICATION Y faster than conventional mounting systems.Trinamount connects directly to the module frame,eliminating the need for long rails. C E " "F%01 y .&R' WARRAN1r ® STANDING SEAM ROOF By drastically reducing the number of parts,cost of materials and l 0,waM1mamMp vgnanN R installation time,Trinamount offers the optimal solution for residential ,C�7,,, :s yea loco penanaa¢aMVrv9y and commercial installations. I IP'easo mlw to pioEUCI MsonN 1a(blolq oA"PIP Trinasolar ® Trinasolar CAUMN REDSAFM AND INSTAlIATION INSTRUCTIONS BEFORE USING THE PRODUCT The pow,,HChHd the panel R The prove,beh'md the morel Owl I TAV Sth LLMM AI IHH'crave.SeeciBCdivu ncbOFOn Irin colon.«ve xbj-1 to crmee wimwl Nock.. i SolarCity SleekMountTM - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zap hardware and Zap compatible Installation Instructions is optimized to achieve superior strength and modules. aesthetics while minimizing roof disruption 0 Drill Pilot Hole of Proper Diameter for and labor.The elimination of visible rail ends •Interlock listed to UL 1703 as ground Fastener Size Per NDS Section 1.1.3.2 bond means and mounting clamps,combined with the • Seal pilot hole with roofing sealant addition of array trim and a lower profile all •Ground Zap UL and ErL listed to UL 467 as — contribute to a more visually appealing grounding and bonding device • Insert Comp Mount flashing under upper system.SleekMount utilizes modules with \ layer of shingle •Full system listed to UL 2703 for grounding strengthened frames that attach directly to • Place Comp Mount centered Zap standoffs,effectively eliminating the .Galvanized aluminum waterproof flashing upon flashing need for rail and reducing the number of standoffs required. In addition,composition •Anodized components for corrosion resistance Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this with sealing washer. system,allowing for minimal roof disturbance. •Applicable for vent spanning functions _ • Secure Leveling Foot to the Comp Mount using machine Screw • Place module • Components ® • 5/16"Machine Screw • Zap Leveling Foot • Lag Screw • Zap Comp Mount • • Zep Comp Mount Flashing Btdldirg Oal rhnent • J J 2 9 2013 RE -1,VEDFOR Q 1U:RLiQNCE ®° RG'v;ovwvod Bjf: i SolarCity, JanUaty213 SolarCity, January2013 E:t•NSwitching Devices Safety Switches February 2001 r Product Selection 120/240 Vac General-Duty,Fusible,Single Throw Table 8.41.120/240 Vac General-Duty,Fusible,Single Throw System Ampere I Fuse I Maximum Horsepower Ratings O NEMA t Enclosure NEMA 3R Enclosure I Rating Type I Slnele-Phose so 3-Phase ac do ndoor Rainproof 11 Provision 120 Volt 1 240 Vok 240 Vok 260 volt I Catalog I Price Catalog I Prim Number U.S.S Number U.S.a 3-Pole 3-Wne(Three Blades,Tbrae Fdpal-240 Vac 30 — — — — — O pl b b b 60 — — — — — 0) ca 100 - — — = 0) al 200 400 H 50-125 D6325FGK 00 DG325FRK 00 600 H — — 75-200 — DG326FGK DG326FRK 00 4-Wire(Three Blades,Three Rues,Sat)-1211M Vac 1 2 30 H = 1.1/2-3 3-7-1/2 = DG321NGB DG321NR6 60 H 3-10 7-1/2-15 — DG322NGB DG322NRB 100 H 7.12-15 15-30 DG 313 DG323NRB 01 200 H 15 25-60 D6324NGK DG324NRK 400 H 50-125 D6325NGK DG325NRK 600 H — — 75-200 — DG326NGK DG326NRK O Maximum hp ratings apply only when dual element time delay fuses are used. (D Use 4-wire catalog numbers below. O Solid neutral bars are not included.Order separately from Table 8-1 on Page 8.5. -)WARNING[Switch is not approved for service entrance unless a neutral kit is installed. T 120/240 Vac General-Duly,Non-Fusible,Single Throwp� JAH 29 13 REV EXEDFORC '1 eniCE Rev omd'By: OG3MURS Table 8-42120/240 Vac General-Duty,Non-Fusible,Single Throw System Ampere Maximum Homepower Ratings NEMA t Enclosure Rainproof 3�Enclosure Rating Singls-Phase ac 3-Phase ac do I np 12C Vok 240 Vok 240 volt 250 Volt Catalog I Prim +Catalog Price Number U.S.S I Number U.S.$ Non-Fusible-2-Pale 2-Wire(Two Blodn)-240 Vac 1630 2 200 I3 15 I— — IDG2231UGB0 IDDGG223URB OO 3-Pole 3-Wire(Three Blades)-240 We 30 2 3 7-12 — DG327UGB0 DG321UR8 b b b 60 3 10 15 — DG922UG60 DG322UR60 100 — 15 30 — DG323UGBO DG323URB I 200 — 15 60 — DG324UGKO DG 324URK0 400 — — 125 — DG325UGK0 DG325URKO 600 — — 200 — DG326UGKO DG326URK0 O WARNINGI Switch is not approved for service entrance unless a neutral kit is installed. OO Use 3-wire catalog numbers below. Drilled to accept field installed neutral kits. Note:All general-duty safety switches are individually packaged. • Note:Accessories are limited in scope on general-duty safety switches.See Page"for availability.In addition,clear line shields are available as an accessory on 200-600 ampere general-duty switches.Catalog Numbers:200 A-70-7759-11,400 A=70-8063-8,600 A=70-8064-8. Discount Symbol.........................22CD CA08101001E For more information visit www.eaton.com E:T•N Switching Devices February 2007 s Safety Switches Technical Data and Specifications Technical Data and Specifications Dimensions Table 8-26.General-Duty,Plug Fuse,120,120/210 Vol,7-,2-Pole Solid Neutral,Single Throw Ampere NEMA 1 1 / Rating Dimensions In Inches(Mm) Heigh Width I Depth " 30 6.88(174.8) 4.94(125.6) 13.44(87.4) Table 8-27.General-Duty,Non-Fusible,290 Volt,3-Pole,Single Throw 1I Amperes NEMA1 SEMMA3R D2-N Ong I Dimensions in Indus(mm) Wsigh Dimensions in Inches(mm) Weigh Width I Hdlght IIDw"' Depth I bslkg) (ve I Height IIDIt I1� =lkgl General-Duty NIA Fusi30-100 Amperes WkM 30 6.38 10.69 6.88 3.75 6 6.38 10.81 6.88 3.75 6 and Fusible Single Throw (162.1) (271.5) (174.8) (95.2) (2.724) (162.1) (274.6) (174.8) (95.2) (2.724) I Nate:Figure is not applicable to plug fuse. 60 8.69 14.19 7.38 4.21 9 8.69 14.38 7.38 4.21 9 (220.7) (360.4) (187.5) (106.9) (4.088) (220.7) (965.3) (187.5) (106.9) (4.086) 100 9.13 18.81 7.38 4.23 12 9.13 19.25 7.38 4.23 12 _W_ D (231.9) (477.8) (187.5) (107.4) (5.448) (231.9) (489.0) (187.5) (107.4) (5.448) C 1200 16.00 25.25 11.25 6.14 48 16.00 25.50 11.25 6.14 55 (406.4) (641.4) 1285.81 (156.0) (21.792) 1406.41 (647.7) 1285.81 (156.0) 124.97) 400 (584.2) (1 36.7) (320.8) (184.7) (45.4) (584.2) 17 47.8) (320.8) (184.7) (47.67) 800 24.00 52.25 14.25 8.95 130 24.00 52.70 14.25 8.95 135 a " 1609.61 (1327.2) (362.0) (227.3) 159.02) (609.6) (1338.6) (362.0) (227.3) (61.29) I \ 4 Note:Dimensions are for estimating purposes only. c c Table 8-28.General-Duty,Fusible,240 Voh,3-Pole Solid Neutral,Single Throw I N D2+ Ampere NlBNA 1 NENUI9R Ong Dimensions in Inches(mm) Weight Dimensions in Inches Imm) Weigh Figure l-D NEMA 1-3n 200-600 Amperes WWth I Heigh I DaPa1 I Depth bslk9l I Width I Heigh I Depth I D� I lbs Ikgl General-Duty Non-Fusible Iwl (H) ()) 02) IWI (H) to) (D2) and Fusible Single Throw 30 6.38 10.69 6.88 3.75 6 6.36 1021 6.88 3.75 6 (162.1) (271.5) (174.8) 195.21 (2.724) (162.1) (274.6) (174.8) (95.2) (2.724) 60 8.69 14.19 7.38 4.21 10 8.69 14.38 7.38 4.21 10 (220.7) (360.4) (187.5) (106.9) (4.54) (220.7) (365.3) (187.5) (106.9) (4.54) 100 9.13 18.81 7.38 4.23 14 9.13 19.25 7.38 4.23 14 1231.91 (477.8) (187.5) 1107.41 (6.358) (231.9) 1489.01 (197.5) (107.4) (6.356) 200 16.00 24.75 11.25 6.14 48 16.00 25.50 11.25 6.14 55 1406.41 (628.7) (285.8) (156.0) (21.792) (406.4) (647.7) (285.8) (158.0) (24.971 400 23.00 44.75 12.63 7.27 110 23.00 45.19 12.63 7.27 115 1584.21 (1136.7) (320.81 (184.7) (49.94) (584.2) 11147.81 (320.8) (184.7) (52.21) 600 24.110 52.25 14.25 8.95 145 24.00 52.70 14.25 8.95 150 (609.6) (1327.2) 1362.01 (227.3) (65.83) (609.6) 11338.61 1362.0) (227.3) (68.1) Note:Dimensions are for estimating purposes only. CA08101001 E For more information visit www.eaton.com Safety Switches Switching Devices E:T•N Technical Data and Specifications February 2007 Dimensions _VV_ -- D. Table 8.29.General-Duty,Non-Fusible,240Vob,2-Pole Solid Neutral,Double Throw,Compact Design , Ampere I NEMA 3H I � Hating I Dimensions in Inches(mm) weight Height tH) Width IWI I Depth(D) I Depth 11321 I lba(kg) 30 14.69(373.1) 9.63(244.61 10.81(274.6) 5.23(132.8) 7215.51 f p H 60 14.69(373.11 9.83(244.61 10.81(274.6) 15.23(132.8) 12(5.5) 100 14.69(373.1) 1 9.63(244.6) 1031(274.6) 15.23(132.8) 12(5.5) Table 8-30.General-Duty,Non-Fusible,240 Volt.2-Pole Solid Neutral, Double Throw,Quick-Make,Quick-Break Design o Ampere INEMA311 I I•-oa-N Hating I Dimensions in Inches(mm) Weight Height Width lWl bs(k ) � g I (Depth 1131 Depth 1132) g I Figure 83.NEMA 3630-400 Amperes General-Duty Non-Fusible Double Throw 30 24.63 1625.6) 77.941303.3) 9.86(251.0) 5.38(136.7) 34(15.4) 60 24.83(825.6) 11.94(303.3) 9.88(251.0) 5.38(136.71 3405.4) 100 24.63(625.6) 11.94(303.3) 9.88(251.0) 15.3B(136.7) 34(15.4) 200 3738 400 53.81(1( 49.5) 6.8) 123.13(587.5) 12.501317.61 8.88(225.6) 140163.61 For more information visit www.eaton.com CA08101001 E 6 •. vY _L ' • Y INSTALLATION MANUAL UL 1 703 VERSI N' rims®Bar TSM_UL 1703_IM_2011_RevA The power behind the panel INSTALLATION MANUAL 0 L 1703 version 1. DISCLAIMER OF LIABILITY The Installation,handling and use of Trina Solar Crystalline series modules are beyond company control.Accordingly, Tnna Solar does not assume responsibility for loss,damage, injury or expense resulting from improper Installation, handling,use or maintenance. Trina Solar assumes no responsibility for any infringement of patents or other rights of third parties that may result from use of the module.No license is granted by implication or under any patent or patent rights Specifications included in this manual are subject to change without prior notice. 2. SAFETY PRECAUTIONS •When designing the SPV system, please always take into consideration the variation of the voltage under different temperatures(please check the respective temp.coefficients of the modules, the Vac of the modules will be rise when the temperature drops), For example:with TSM-190DC01 modules(Max System voltage is 600V)the maximum series modules configuration number should NEVER can exceed N=10(600V/56.22V= 10 7),taking into consideration the possible variation of the voltage due to the lowest temperature in winter at specified location can reach-40C. •We require that every series SPV module string should be fused prior to be connected with other strings. For the maximum fuse rate,please refer to the detailed specification sheet.. • Solar photovoltaic (SPV) modules generate electricity when exposed to light.An array of many modules can cause lethal shocks and/or burn hazards.Only authorized and trained personnel should have access to the modules • Use properly insulated tools and appropriate protective equipment to reduce risk of electric shock • Do not stand or step on the module • Do not damage or scratch the front or backside surfaces of the module. • Never use a module with broken glass or torn substrate.Broken modules cannot be repaired and contact with any module surface or frame can lead to electrical shock. • Do not disassemble the modules or remove any part of the module. Protect plug contacts against soiling;do not make any plug connections using soiled plug contacts. • Do not Install or handle modules when they are wet or during periods of high wind • Do not short the positive and the negative of a single SPV module. • Do not disconnect under load. • Make sure connectors have no gap between insulators A gap can cause fire hazard and/or danger of an electrical shock r - • Make sure that the polarity of each module or a string is not reversed considering the rest of the modules or strings • Artificially concentrated sunlight should not be used on the SPV module • Maximum system voltage must not exceed 600V DC • Under normal conditions,a solar photovoltaic module is likely to produce more current and /or voltage than reported under standard test conditions.Accordingly,the value of Isc marked on this module should be multiplied by a factor of 1.25 when determining the conductor current ratings,fuse sizes and size of controls connected to the SPV output.Refer to Section 690-8 of the National Electric Code for an additional multiplying factor of 1.25 which maybe applicable. • Installation in Canada shall be in accordance with CSA C22 1,Safety Standard for Electrical Installations,Canadian Electrical Code Part 1 3. UNPACKING AND STORAGE • Before installation,keep all modules and electrical contacts clean and dry • If it Is necessary to store modules temporarily,a dry,ventilated room should be used. • When unpacking,carry modules with both hands.Do not place modules on top of each other. 4. PRODUCT IDENTIFICATION We recommend that you take note of the serial number,each Individual module has a unique serial number. It is permanently attached to the backsheet of the module on the product sticker. 5. ENVIRONMENTAL CONDITIONS AND SITE SELECTION 5.1 CLIMATE CONDITION Ambient temperature: -WC to+4o°C Install Trina Solar Crystalline series modules in-the Operating Temperature. -40'c to+85'C following conditions: Storage Temperature: -20`C to♦40-C Note:Mechanical load bearing(include wind and snow Humidity beiow85RH% loads) of the module is based on mounting methods. Mechanical toad Pressure, below 11278Ibs/ft2(54(1 Trin-asolar 2 INSTALLATION MANU UL 1703 tR' 1 Professional system installer must be responsible for mechanical load calculation according to system design. 5.2 SITE SELECTION In most applications,Trina Solar SPV modules should be Installed In a location where they will receive maximum sunlight throughout the year. Modules should not be shaded at anytime of the day because of buildings,trees,chimney,etc. Do not install SPV modules in corrosive environment,such as corrosive salt areas within proximity of the ocean or sulfurous area,etc. Do not install SPV modules in a location where it would be immersed in water or continually exposed to water from a sprinkler or fountain,etc. • modules should be mounted over a fire resistant covering,with adequate ventilation between the module backsheet and the mounting surface.Clearance between the module frames and surface of the wall or roof is required to prevent wiring damage and to allow air to circulate behind the module.The required minimal stand- off height is 115mm.Any slope less than 5in/ft(127mm/305mm)is required to maintain a fire class rating Do not mount SPV module in such way that the drain holes of SPV module are intended to block up, 5.2 SITE SELECTION Trina Solar SPV modules connected in series should be installed at same orientation and angle.Different orientation or angle may cause loss of output power due to difference of amount of sunlight exposed to the module. Typically,the optimal tilting of SPV module is almost the same as the latitude of Installation location 6. MOUNTING INSTRUCTIONS 6.1 MOUNTING METHODS PV modules can be mounted to the substructure using the following methods: (1) Screw fitting:Using corrosion-proof screws (M8) in the existing installing holes in the .. module frame. The frame of each module has s,, > 2 4 mounting holes used to secure the modules to supporting structure. -- -�---- - - -�Tic� Module frame must be attached to a tell mounting rail using M8 corrosion-proof Rgurel.SPV module Installed with Screw fitting method screws together with spring washers and flat ,)Aluminum Frame 2) M8 Stainless spew washers in four symmetrical locations on the 3)Flat stainless washer 4) Spring Stainless Washer SPV module. s)FIEx stainless Nutt The modules have been evaluated by for mounting using the 4 provided mounting holes In the frame. • Applied torque should be 8 Newton-meters Please find detailed mounting Information in the below illustration: (2) Clamp fitting:Using suitable module clamps on the side of the module frame to mount the modules(including "portrait orientation"and'landscape orientation') • Use a certain number of clamps to fix modules on the mounting rail. • Modules clamps should not come into contact with the front glass and must not deform the frame • Be sure to avoid shadowing effects from the module clamps. • The module frame is not to be modified under any circumstances • When choosing this type of clamp-mounting method, please be sure to use at least four clamps on each module,two clamps should be attached on the long sides of the module(for portrait orientation)and short sides of the module(for landscape orientation).Depending on local wind and snow loads,additional clamps may be required to ensure modules can bear the load. Applied torque should be 8 Newton-meters.Please find detailed mounting information in the below Illustration Fringe modules installation Middle modules Installation AL lIil Figure2.SPV module installed with clamp fitting method 3 "true-asolar K, INSTALLATION 1703version Note • Clearance between modules frames and surface of the wall or roof Is required to prevent wiring damage and to allow air to circulate behind the module.Recommended stand-off height is I I5mm. • Do not mount SPV modules In such way that drain holes of modules are blocked. We recommend to use the landscape and portrait orientation to Install the module,Please note the diagram below when Install: 1/20Module Width Mounting I/5 Module Width Area I i Mounting 1/5 Module Width -., N' Area 1/20 Module Width hgure3 Mechanical dimensions when modules installed at lonentation with Clamp fitting method 1/8 Module Wdth Mounting 1/4 Module Width Area 1/4 Module Width * Mounting Area 1/8 Module Wdth hi Mechanical dimensions when modules installed to portrait orientation with clamp fitting method 62 GROUNDING All module frames and mounting racks must be properly grounded In accordance with appropriate respective national electrical code. • Proper grounding is achieved by bonding the module frame(s) and all metallic structural members together continuously using a suitable grounding conductor.Grounding conductor or strap may be copper,copper alloy, or other material acceptable for use as an electrical conductor per respective National Electrical Codes.The grounding conductor must then make a connection to earth using a suitable earth ground electrode. We recommend to use the following methods to ground properly: 2 3 a 1)Wire bolt and slot 4 2)Mounting wash hex nut 3)Aluminum frame 4)6-12 AWG iabie 5 5)HEX Nut Figures Tyco grounding bolt#2058729-1 Trin-asolar 4 • Tyco Grounding hardware is a package that includes the grounding bolt,mounting and grounding hex nut • Make electrical contact by penetrating the anodized coating of the aluminum frame, by tightening the The mounting wash hex nut(come with the star washer)to the proper torque(25 in lb.) • Select grounding wire size:(6 to 12 AWG solid bare copper)and install underneath wire binding bolt • Tighten wire binding bolt to proper torque(45 in lb). The Tyco grounding bolt is only UL listed for use with 6-12 AWG bare solid copper wire. 6.3 MODULEWIRING Each module has two standard 90'C sunlight resistant output cables each terminated with plug&play connectors.The wire type and gauge of the output cables are 600V rated PV Wire cable and are 12AWG in size. This cable is suitable for applications where wiring is exposed to the direct sunlight.We required that all wiring and electrical connections comply with the appropriate national electrical code. For field connections,use the minimum 12AWG copper wires insulated for a minimum of 90'C and Sunlight resistance with insulation designated as PV Wire. • The minimum and maximum outer diameters of the cable are 5 to 7mm'. 7. MAINTENANCE AND CARE • Under most weather conditions,normal rainfall is sufficient to keep the PV module glass surface clean.If dust or dirt build-up becomes excessive,clean the glass only with a soft cloth using mild detergent and water. • Do not clean the modules with cold water during the warmer hours of the day in order to avoid creating any thermal shock that may damage the module. Be cautious when cleaning the back surface of the module to avoid penetrating the substrate material.Modules that are mounted flat(0°tilt angle)should be cleaned more often,as they will not"self clean"as effectively as modules mounted at a 150 tilt or greater. At least once a year,it is recommended to check the torque of terminal screws and the general condition of wiring. Also,check that mounting hardware is properly torqued.Loose connections will result in damage for the array. • Modules that have been replaced must be of same type Do not touch live parts of cables and connectors. Use appropriate safety equipment(insulated tools,insulating gloves,etc.)when handling modules. Cover the front surface of modules by an opaque material when repairing. Modules when exposed to sunlight generate high voltage and are dangerous. Trina Solar SPV modules are equipped with bypass diodes in the junction box This minimizes module heating and current losses. Do not try to open the junction box to change the diodes even if it malfunctions • In a system that uses a battery,blocking diodes are typically placed between the battery and the SPV module output to prevent battery discharge at night. WARNING:For any electrical maintenance,the PV system must first be shut down.Improper maintenance can cause lethal electric shock and/or burns. 5 Trinasolar le Irmusolar The power behind the panel ASIA PACIFIC AUSTRALIA - CHINA Headgoarferz r ,i rnr r r r. uv r r T . F r. rrt i EUROPE CHINA .. f'r�. ... GERMANY rr is r q. T F . .r .. CHINA ITALY T r •.fOtG E SPAIN KOREA r Trrna Solar Korea Ltd. T E T Ir F SWITZERLAND European 110 Trrna Solar ISehweml AG JAPAN Taw SolarJal..Ltd r r r E r „r T . F E NORTH AMERICA U.S.A. Trrna Snlzr IU S I.Ire _ T F www.trinasolar.com CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 21690 ALCAZAR AVE CONTRACTOR:SOLARCITY PERMIT NO:13010144 OWNER'S NAME: YOUNG CHARLES C ET AL 3055 CLEARVIEW WAY DATE ISSUED:01/29/2013 OWNER'S PHONE: 6509262669 SAN MATEO,CA 94402 PHONE NO:(650)638-1028 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL COMMERCIAL[] License Class C Lie.# 24 PANEL ROOF TOP FLUSH-MOUNTED PHOTOVOLTAIC �ur y 6A2/13 SYSTEM(5.88KW) Contractor �D �� Date I hereby affirm that I am licensed under the provisions of Chapter 9 REVISION#1-CHANGE INVERTER-ISSD OTC 6/12/13 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations:, I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for tke, performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$25000 I have and will maintain Worker's Compensation htsu for by Section 3700 of the Labor Code,for the perform for which this APN Number:35719097.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 1 0 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAY R LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the granting of this pe dditionally,the applicant understands and will comply Issued by: Date: with all non- ' t s c regulations per the Cupertino Municipal Code,Section �� 9.18. V RE-ROOFS: Signa _ Date 3 All roofs shall be inspected prior to any roofing material being installed.If a roof is / installed without first obtaining an inspection,I agree to remove all new materials for G inspection. ❑ OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my-employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. 1 will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 02 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the C no unicipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Secti s 25 25 33,and 25534. Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized ag nt• Date: permit is issued. I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 CUPERTINO (408)777-3228•FAX(408)777-3333•buildina aacuoertino.oro [:]NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION/Ti Ems, E ISION/DEFERRED ORIGINAL PERMIT# PROJECT ADDRESS 2 47d) APN# OWNERNAME 1/ / / ` I PHONE I E-MAIL STREET ADDRESS I CITY, STATE,ZIP I FAX CONTACT NAME I PHONE I E-MAIL STREET ADDRESS I CITY,STATE,ZIP I FAX ❑OWNER ❑ OwNER-BUIIAER ❑ OWNER AGENT ❑ CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑TENANT CONTRACTOR NAME C o LICENSE NUMBER gCj (J' LICENSEE%, BUS.LIC COMPANY NAME E-MAIL # FAX STREET ADDRESS '7 r r CITY,STATE,ZIII�O S �+ fy d e� Ld4 PHONE -� ARCHITECT/ENGINEER NAME LICENSE NUMBER , ( t ( / / BUS.LIC# 7 COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE DESCRIPTION OF WORK EXISTING USE I PROPOSED USE I CONSTR-TYPE I #STORIES USE TYPE OCC. SQ.FT. VALUATION($) AREA AREA I NEW I AREA I TOTAL AREA BATHROOM I KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA - PORCH AREA I DECK AREA TOTAL DECKNORCH AREA 1 GARAGE AREA: ❑DETACH []ATTACH #DWELLING UNITS: I IS A SECOND UNIT ❑YES SECOND STORY OYES BEING ADDED? ❑NO ADDITION? []NO PRE-APPLICATION ❑YES IF YES,PROVIDE COPY OF IS THE BLDG AN ❑YES =CEIYIEDlBY��:a,Y'�� S: 1+'`t." °i--�'i"a TOTAL-VLUATION: . <. : ' PLANNING APPL# ❑NO PLANNING APPROVAL LETTER EICHLER HOME? ❑NO `�I';§ By my signature below,I certify to each of the following: I am the property owner or authorizecI!�4ent to act on the property owner's behalf. I have read this application and the information I aveps vided'rect. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relati t ildl g c ction. I authorize representatives of Cupertino to enter the ab vq�ident'ed property for inspection purposes., Signature of Applicant/Ag t: Date: l2 SUPPLEMENTY_RIFO T ON REQUIRED //// PLAN:C>IECKT.YPE ai,^.i. Vin',n . ,b, • .OI�IIN.GSISIP.,, _New SFD or Multifamily dwellings: Apply for demolition permit for u . � '_� •. - o:_ existing building(s). Demolition permit is required prior to issuance of buildings permit for new building. _Commercial Bld s: Provide a com leted Hazardous Materials Disclosure ,rw:ST m °' iC= iiic Rl ' y. ' form if any Hazazdous Materials aze being used as part of this project. - _ ' ., Co pY of Plannin A PP royal Letter or Meetin with Plannin g Prior to submittal of Building Permit application. ., BldgApp_2011.doc revised 06/21/11 i ABBREVIATIONS ELECTRICAL NOTES INDEX LICENSE JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING PV1 COVER SHEET CA # 888104 MEANS MAY BE ENERGIZED IN THE OPEN PV2 SITE PLAN C-46, C-10 AC ALTERNATING CURRENT POSITION, A SIGN WILL BE PROVIDED WARNING PV3 STRUCTURAL VIEWS BLDG BUILDING OF THE HAZARDS PER ART. 690.17. PV4 STRUCTURAL VIEWS CONC CONCRETE 2. EACH UNGROUNDED CONDUCTOR OF THE PV5 UPLIFT CALCULATIONS C COMBINER BOX MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PV6 THREE LINE DIAGRAM OFFICE COPY D DISTRIBUTION PANEL BY PHASE AND SYSTEM PER ART. 210.5. PV7 ELECTRICAL CALCULATIONS DC DIRECT CURRENT 3. A NATIONALLY-RECOGNIZED TESTING PV8 SITE PLAN PLACARD EGC EQUIPMENT GROUNDING CONDUCTOR CUTSHEETS ATTACHED (E) EXISTING LABORATORY SHALL LIST ALL EQUIPMENT IN � EMT ELECTRICAL METALLIC TUBING COMPLIANCE WITH ART. 110.3. G SOLAR GUARD METER 4. CIRCUITS OVER GROUND SHALL ■■ GALV GALVANIZED COMPLY WITH ART.RT. 25 0. 250.92(6) CUTSHEETS ATTACHED DO NOT ENTER REW,0 #­� . GEC GROUNDING ELECTRODE CONDUCTOR 5. DC CONDUCTORS EITHER DO GND GROUND BUILDING OR ARE RUN IN METALLIC RACEWAYS GENERAL NOTES HDG HOT DIPPED GALVANIZED OR ENCLOSURES TO THE FIRST ACCESSIBLE DC Installing 24-roof top flish-mounted panels (5.88kW). I CURRENT DISCONNECTING MEANS PER ART. 690.31(E). Standard breaker tie in (30A) at main panel. Imp CURRENT AT MAX POWER 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN 1. THIS SYSTEM IS GRID-INTERTIED VIA A Inverter and AC disconnect to go in garage. I RELIEF AT ALL ENTRY INTO BOXES AS UL-LISTED POWER-CONDITIONING INVERTER. COMMUNITY DEVELOPMENT DEPARTMENT Isc SHORT CIRCUIT CURRENT REQUIRED BY UL LISTING. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. BUILDING DIVISION-CUPERTINO INVERTERS kVA KILOVOLT AMPERE 7. MODULE FRAMES SHALL BE GROUNDED AT THE 3. PHOTOVOLTAIC SOURCE AND INPUT CIRCUITS AND kW KILOWATT UL-LISTED LOCATION PROVIDED BY THE INVERTER INPUT CIRCUIT ARE UNGROUNDED. APPROVED LBW LOAD BEARING WALL MANUFACTURER USING UL LISTED GROUNDING 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED This set of plans and specifications MUST be kept at the MIN MINIMUM HARDWARE. 5. ALL WORK TO BE DONE TO 2010 CALIFORNIA jcb site during construction. It is unlawful to make any BUILDING CODE. changes or alterations on same,or to deviate MIR MIRROR 8. ALL EXPOSED METAL PARTS (MODULE FRAMES, 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE tl lerefrom without approval from the Building Official. 2008 NA NEC NATIONAL ELECTRIC CODE UL LISTED LAY-IN LUGS LISTED FOR THE THE 2NA CALIFORNIA ELECTRIC CODE. (I s* -.iping of this plan and specifications SHALL NOT NIC NOT IN CONTRACT PURPOSE. POSTS SHALL BE MADE lb)held to permit or to be an a NTS NOT TO SCALE ELECTRICALLY CONTINUOUS WITH ATTACHED o'an approval of the violation y provisions of any City Ordinance or State Law. OC ON CENTER RAIL. P PANEL BOARD 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE PL PROPERTY LINES BONDED WITH EQUIPMENT GROUND CONDUCTORS DATE (D I z. 13 PV PHOTOVOLTAIC AND GROUNDED AT THE MAIN ELECTRIC PANEL. rtH MIT NO. —I 6 PVC POLYVINYL CHLORIDE 10. THE DC GROUNDING ELECTRODE CONDUCTOR VICINITY MAP - -- - -- S SUBPANEL SHALL BE SIZED ACCORDING TO ART. SCH SCHEDULE 250.166(B) & 690.47. SS STAINLESS STEEL •� - SSD S SEE STRUCTURAL DRAWING ' STC STANDARD TESTING CONDITIONS :,- *^ = o µ�►y�- ,.;---, I,lI m p t , `�, .. , � `� - CUhE RTINO SWH SOLAR WATER HEATER TYP TYPICAL Building Department LION UNLESS OTHERWISE NOTED UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT w ` - .. ="j JUN 1 2 2013 Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT EVIEVVED FOR CODE COMPLIANCE r ;`y J +�,, y W WATT 3R NEMA 3R, RAINTIGHT �!; ,���� �"'` � : Reviewed By: � , r " REV BY DATE COMMENTS A WL 6/14 Simply switched inverter to Power One 4.2, nothinq else chanqes, thank you i 40 .-�;•- IT r _ •: Vii'" ,r. -- _, w, , _ � � .. PREMISE OWNER: W. Cupertino DESCRIPTION: DESIGN: '�►I�' CONFIDENTIAL— THE CONTAINED HALL NOT BEMUSED OR THE I "AMBER: J B-9501188 00 YOUNG, CHARLES YOUNG RESIDENCE SPETE —,,,%P, ,, BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: 'I, S wattity, NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI (24) TRINA SOLAR # TSM-245PC05/PA05.18 21690 ALCAZAR AVE 5.88 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS PRDJECT MANAGER: MOUNTING SYSTEM: CUPERTINO, CA 95014 ���r� ORGANIZATION, EXCEPT IN CONNECTION WITH Y r 3055 Clearview Way San Mateo,CA THE SALE AND USE OF THE RESPECTIVE Comp SleekMount Type C 94402 SOLARCITY EQUIPMENT, WnHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. PAYMENT TYPE: IN TER: 262669 PV 1 A 1/25/2013 (888)-SOL-QTY(765-2489)www.solarcity.com PPA (1� POWER-ONE # AURORA PVI-4.2-OUTD-S COVER SHEET i - PITCH: 27 ARRAY PITCH:27 MP1 AZIMUTH: 181 ARRAY AZIMUTH: 181 I I 21690 Alcazar Ave i MATERIAL: Comp Shingle STORY: 1 Story ARRAY PITCH: 27 MP2 AZIMUTH:270 ARRAY AZIMUTH:270 MATERIAL:Comp Shingle STORY: 2 Stories I I I I i I I I I I . I I Front Of House CUPERTINO Building Department I I I I JUN 12 2013 D PV4 REVIEWED FOR CODE COMPLIANCE Reviewed By: ' i I LEGEND O ;Inv ; I (E) UTILITY METER & WARNING LABEL I n PV4 INVERTER W/ INTEGRATED DC DISCO AC 5'to PL Ins & WARNING LABELS Z1n-tocKT'a Ga#e&Fen ce) N © DC DISCONNECT & WARNING LABELS AC DISCONNECT & WARNING LABELS 0 JUNCTION BOX Q DC COMBINER BOX & WARNING 10'to PL Q DISTRIBUTION PANEL & WARNING Flashing will be painted to L0 LOAD CENTER & WARNING LABELS match exterior. O DEDICATED PV SYSTEM METER B n Total array area: 430 PV3 � CONDUIT RUN ON EXTERIOR Total roof area: 1500 sq. ft. CONDUIT RUN ON INTERIOR M131 Total array area is 30% of — GATE/FENCE T roof area. --- INTERIOR EQUIPMENT A SITE PLAN N PV3 zo'to PL Scale: 1/8" = 1' W E 0 1' 8' 16' S CONFIDENTIAL- 'ME INFORMATION HEREIN p6 NUMBER PREMISE OWNER AHJ Cupertino DESCRIPTION: DESIGN: `�Nx CONTAINED SHALL NOT BE USED FOR THE JB-9501188 00 YOUNG, CHARLES YOUNG RESIDENCE SPETE �.,���� BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET. MODULES ��� coiarC'� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI (24) TRINA SOLAR # TSM-245PC05/PA05.18 21690 ALCAZAR AVE 5.88 KW PV Array I m PART TO OTHERS OUTSIDE THE RECIPIENT'S PROECT MANAGER: MOUNTING SYSTEM: CUPERTINO CA 95014 ORGANIZATION,EXCEPT IN CONNEC11ON WITH 3055 Clearview Way San Mateo,CA THE SALE AND USE OF THE RESPECTIVE Comp SleekMount Type C PAGE NAME: SHEET: REV: DAZE: 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: IN TER: 262669 PV 2 A / / T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. I PPA 1� POWER—ONE # AURORA PVI-4.2—OUTD—S f SITE PLAN 1 25 2013 (888)-SOL-CnY(765-2489)www.solarcity.com J (E) 2x8 RAFTER ® 24" O.C. S1 E RIDGE BOARD (E) 2x6 (E) LBW 2' (E) 2x8 RAFTERS -6' _7» @ 24" SPACING (E) LBW RAFTER: 2x8 FRONT VIEW O F M P 1 SUPPORT: 2x8, 2x12, 2x6 OB MAX SPAN: 8'-7" SCALE: 1/2" = 1' A SIDE VIEW OF MP1 SCALE: 1/4" = 1' PV MODULE " BOLT WITH LOCK & INSTALLATION ORDER FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. ` (4) I C2)1 SEAL PILOT HOLE WITH ZEP COMP MOUNT C POLYURETHANE SEALANT. ZEP FLASHING.0 (3) (3)I INSERT FLASHING. (E) COMP. SHINGLE (1) (4)I PLACE MOUNT. (E) ROOF DECKING �� (2) V INSTALL LAG BOLT WITH " LAG BOLT WITH (5) (5)I SEALING WASHER. I CUPERTINO SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES (6)1 INSTALL LEVELING FOOT WITH v Building Department BOLT & WASHERS. (E) RAFTER JUN 12 2013 S♦ STANDOFF REVIEWED FOR CODE COMPLIANCE 1 Scale: 1 1/2" = 1' • Reviewed By: , � CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER PREMISE OMR: AH,k Cupertino DESMPTION: DESIGN: `���% CONTAINED SHALL NOT BE USED FOR THE J B-9501188 00 YOUNG, CHARLES YOUNG RESIDENCE SPETE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES 'I' SolarC�ty. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI (24) TRINA SOLAR # TSM-245PC05/PA05. 8 21690 ALCAZAR AVE 5.88 KW PV Array /,1 1 I o PART TO OTHERS OUTSIDE THE RECIPIENTS PROJECT MANAGER MOUNTING SYSTEM: CUPERTINO, CA 95014 (��i/.�,�.► ORGANIZATION,EXCEPT IN CONNECTION WITH 3055 Clearview Way San Mateo,CA THE SALE AND USE OF THE RESPECTIVE Comp SleekMount Type C 94402 SOLARCITY EQUIPMENT,WTHOUT THE WRITTEN PAGE NAME: SHEET. REV. DAIS T:(650)638-1028 R(650)638-1029 PERMISSION OF SOLARCITY INC. PAYMENT TYPE IN TER: 262669 PV 3 A 1/25/2013 (888)-SOL-CrrY(765-2489)www.solarcity.com Ppq (1 POWER—ONE # AURORA PVI-4.2—OUTD—S STRUCTURAL VIEWS (E) 2x6 RAFTER ! ' ® 24" O.C. S2 (E) 2x8 RIDGE BOARD (E) 2x6 10 2' (E) 2x6 RAFTERS 3'_ —� (E) 2x6 CEILING @ 24" SPACING JOIST @ 24" O.C. (E) LBW (E) LBW RAFTER: 2x6 SUPPORT: 2 FRONT VIEW OF MP2 x6, 2x8 OD MAX SPAN: 9'-1" SCALE: 1/2" = 1' C SIDE VIEW OF MP2 SCALE: 1/4" = 1' PV MODULE " BOLT WITH LOCK & INSTALLATION ORDER FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. — ` (4) (2)1 SEAL PILOT HOLE WITH ZEP COMP MOUNT C / POLYURETHANE SEALANT. ZEP FLASHING C (3) (3)I INSERT FLASHING. (E) COMP. SHINGLE (1) l (4)I PLACE MOUNT. (E) ROOF DECKING V� (2) V INSTALL LAG BOLT WITH LAG BOLT WITH (5) (5)I SEALING WASHER. I `_ CUPERTINO SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES (6)1 INSTALL LEVELING FOOT WITH Building Departrnent E RAFTER BOLT & WASHERS. JUN 12 2013 SZ STANDOFF REVIEVti�EC rOR CODE CO�,M/�PLIANCE Scale: 1 1/2" = 1' Reviewed By: `yr d� PREMISE ONNER: W Cupertino DESCRIPTION: DESIGN: ` �Ii CONFlDENIIAL— THE INFORMATION HEREIN ,IDB NUMBER J B-9501188 00 SPETE �- CONTAINED SHALL NOTCE USED FOR THE YOUNG, CHARLES YOUNG RESIDENCE SolarCity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: � NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI (24) TRINA SOLAR # TSM-245PC05/PA05. 8 21690 ALCAZAR AVE 5.88 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS MANAGER MOUNTING SYSTEM: CU P E R TI N O, CA 95014 flfYJI/t ORGANIZATION.EXCEPT IN CONNECTION WITH 3055 Clearview way San Mateo,CA THE SALE AND USE OF THE RESPECTIVE Comp SleekMount Type C PAGE NAME SHEET: REV: DATE 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: IN TER x:(650)638-1028 R(650)638-1029 PERMISSION of SOLARarr INC. PPA (1� POWER—ONE # AURORA PVI-4.2—OUTD—S6M262669 STRUCTURAL VIEWS PV 4 A 1/25/2013 (888)-SOL-CnY(765-2489)www.solarcity.con UPLIFT CALCULATIONS 1/28/2013 SoiarCit y SleekMoun " Version # 4.1 Project Inforniation System &MP Information Symbol Value Related Info Occupancy Category 11 PV System Type SolarCity SleekMount"' PV Module Trina Solar TSM-245PC Total Number of Modules 24 Roofing Material Camp Roof (dumber of Layers(Comp Roofs Only) 1 Tile Reveal(Tile Roofs Only) NA Roof Slope 270 Spanning Vents? No PV Module Orientation Landscape and Portrait PV Module Length 3,3 ft PV Module Width 5.4 ft Attachment Type Comp Mount Type C Total Square Feet of Arra,, 423 -4 Wind Design Criteria Vrind Design Code ASCE 7-05 Partially/Fully Enclosed Method Exposure Category 8 Section 6.5.6.3 Basic Wind Speed V 85 mph Fig.6-1/Local Data Least Horizontal Dimension of Building LHD Roof Style Gable Roof Fig.6-11B/C/D-14A/B Paean Roof Height h 15 ft Section 6.2 WI zone Interior Edge Corner V.1ind Pressure Up (psP,, P,.1I -10.0 -1).4 -27.0 Wind Pressure Down (psf) p(dov:n; 10.1­1 In,ii 1Ci.Ci Snow Design Criteria Coeff icients Ground Snov,, Load pg Table 7-1r'Local Data Comp Allowable Attachment Spacing (inches)and Tributary Area (sf) Interior Edge Corner Maximum Allowed Foot Spacing_ Landscape 72" 72" 72" CUPERTINO Maximum Allowed Cantilever Landscape 24" 24" 24" Building Department Max Standoff Tributary Area TrIbCL 20 sf 20 sr 20 sf PV Assembly Dead Load V1PV 3 psf p-•r 3 psf JUN 12 2013 DLPV PCL 59 Ibs 59 Ibs 59 Ibs REVIEWED FOR CODE COMPLIANCE , 451LU P- 0.6 DLPV TCL -160 Ibs -304 Ibs -492 Ibs Attachment Uplift Capacity Tallow 637 Ibs 6='.7 Ib 637 Ibs Reviewed By: j�• TCL,rTallow DCRLand 25.1"1 47.7'_ 77.2% CONFIDENTIAL THE INFORMATION HEREIN pB NUMBER PREMISE OWNER: AHD. Cupertino DESCRIPTION: DESIGN: `,kd,4 JB-9501188 00 SPETE CONTAINED SHALL NOT E USED FOR THE YOUNG, CHARLES YOUNG RESIDENCE •.,,,•soia�'t BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: �/� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RE,5) ,(241 TRINA SOLAR # TSM-245PC05 PA05. 8 21690 ALCAZAR AVE 5.88 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS MANAGER Mouenlvc SYSTEM: CUPERTINO, CA 95014 ORGANIZATION, EXCEPT IN CONNECTION NTH pROECT � 3055 Clearview way San Mateo,CA THE SALE AND USE OF THE RESPECTIVE Comp SleekMount Type C 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: INVEk1M PAGE NAME: SHEET: REV: DATE T:(650)638-x,028 F:(650)636-1029 PERMISSION OF SOLARCITY INC. 262669 PV 5 A 1/25/2013 (888)-SOL-CrrY(765-2489)www.solarcity.corn P„A., POWER—ONE # AURORA PVI-4.2—OUTD S UPLIFT CALCULATIONS GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTS SR PENS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD (E) 200A MAIN SERVICE PANEL Inv 1: DC Ungrounded INV 1—(1)POWER–ONE#AURORA PVI-4.2–OUTD–S–US–Z —(24)TRINA SOLAR/TSM-245PCO5/PAO5.18 CA # 888104 Inverter, 4200W,24OV, 967. PV Module; 245W,222.9W PTC,40MM,Blade Frame C-46, C-10 AT PANEL WITH IRREVERSIBLE CRIMP Multiple Main Breakers (6 or fewer) Voc: 37.3 Panel Number:CH INV 2 Vpmax:30.7 Meter Number:1006679880 *MODULE CURRENT RATINGS ARE SHOWN AS Isc AND Imp IN INV 3 THE DC STRINGS IDENTIFIER OF THE SINGLE LINE DIAGRAM. MAIN SERVICE PANEL. Inverter I IND CUTLER—HAMMER 1 Disconnect n POWER—ONE DC,00 NOT,ADJUST MIN.ACTIVATION V MLTAGE AURORA PVT-4.2—OUTD—S—US—Z I I DC- –�--1 Strings)Of 12 On MP 2E LOADS ------------ ( ) A _ L1 Z4o� --------------------- _♦ I �� I I GFP/GFCI 1 30A/2P _—__ GN _ I _____–__----------------______–___–I _EGC/ p+ I 2 DC+DO NOTAD]USiMIN.ACTIVATIONV LTAGE A r GEC DC- I DC. 1 String(s)Of 12 On MP 1 B GND –––JEGI -- -- --––––––—––––––––– --–––––––––– – EGC3 ---j I I I (1)Conduit Kit; 3/4'EMT N I I EGC/GEC z z c� TO 120/24)V SINGLE PHASE UTILITY SERVICE I I I I CUPERTINO Building Department JUN 12 200 REVIEWED FOR CODE COMPLIANCE Reviewed By: J�' POI (1)CUTLER–HAMMER#BR230 PV BACKFEED B ER Q I—(1)CUTLER–HAMMER/DG221URB A� DC Breaker 30A// Spaces ' ` I Disconnect; 30A,240VM Non–Fus�le,NEMA 3R —(1)Ground Rod; 5�2 x 8,Copper —(1)CUTLER–HAMMER#DG030NB Ground/Neutral Kit; 30A,General Duty(DG) 1)AWG#10,THWN-2,Black (2)AWG#10,PV WIRE,Blade Voc =447.6 VDC Isc =8.47 ADC O14t (1)AWG#10,THWN-2,Red O (1)AWG 110,Solid Bare Copper EGC Vmp =368.4 VDC Imp=7.98 ADC II II (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=20 AAC • . . .{1)Conduit Kit;.3/4',EMT. . . . . . . . . . . . .. .. .. .. .. .. . . .. . . . . .. .. . . —{1)AWG Ilk THAN-2,,Green• . EGC/GEC.-(1•)Conduit•Kit;.3/4' EMT. • _. . . _ .. (2)AWG#10,PV WIRE,Blade Voc =447.6 VDC Isc =8.47 ADC O P(1)AWG#10,Solid Bare Copper EGC Vmp =368.4 VDC Imp=7.98 ADC . .. . .I. . .. . . . .. .(1)Conduit Kit:.3/4 EMT. . . . .. . . .. ... . .. . . .. .. .. . . . . . . .. . . .. .. CONFIDENTIAL– THE INFORMATION HEREIN JOB NINABER PREMISE OWNER AHJ: Cupertino DESCRIPTION: DESIGN: CONTAINED SHALL NOT BE USED FOR THE I JB-9501188 00 YOUNG, CHARLES YOUNG RESIDENCE SPETE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES � �Of��I NOR SHALL IT BE DISCLOSED IN WHOLE OR IN I RESI (24) TRINA SOLAR 4 TSM-245PC05/PA05. 8 21690 ALCAZAR AVE 5.88 KW PV Array a PART IZ OTHERS OUTSIDE THE RECIPIENTS PROJECT MANAGER: MOUNTING SYSTEM: CUPERTINO, CA 95014 ORGANIZATION,EXCEPT IN CONNECTION WITH 3055 Clearview Way San Mateo,CA THE SALE AND USE OF THE RESPECTIVE Comp SleekMount Type C 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV DALE: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. IPAYMENr TYPE: '" POWER—ONE # AURORA PVT-4.2—OUTD—S� 262669 THREE LINE DIAGRAM PV 6 A 1/25/2013 (888)-SOL-CrIY(765-2489)www.solarcity.com 1. Conductor Sizina Der Art 690.8(8)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous AL CALCULATIONS current per Art 215.2(A)(1). Module: 24 TRINA SOLAR#TSM-245PCO5 222.9 Inv Porer WPTC Voltage Drop Calculations Version 5_8.0 Inverter 1: 1 Power-One PVI-4.2-S 0.96 4800 5162 Vdrop= Imp) * (2*Length)*(Resistance) / Vmp) b. Conductor must have (after corrections for conditions of use) >= Module: ` Imp(A) I Max.Length(ft) I Wire er Table 310.15(B)(16). Inverter 2: 1 String: 7.98 80 J AWG-10 at Max Ave Hi:82 deg F continuous current p Module:( / Vdrop= (7.98 *160 *0.001240hms) / 335.568 0.47 Branch: 1 7.98 I 0 1 AWG_10 at Max Ave Hi:82 deg F Inverter 3:� I Vdrop 7.98 *0 *0.001240hms / 335.568 0 c. Evaluate conductor temperature at terminations per 110.14(C). Module: � p= ( ) Ampacity of wire derated for conditions of termination must be >= Inverter4:� Total voltaoe droo in VV conductors= 0.47 continuous current*1.25. All string erminations are rated at 90' C. Inverter: 1 7.98 1 20 ] 2 Ohms 10 at 0 V 9 Vdrop= (7.98 *40 *0.0012 Ohms) / 240 V 0.1596 ------------------------------------------ Total: 24 I Modules Total Inv Pwrl 4800 5135.6 1 PTC Combined 0 I 0 1 at 240V 2. OCP Sizina Der Art 690.8(8)(1) Photovoltaic Module Electrical Specifications: Total STC:If 5880 Vdrop= (0 *0 Ohms) / 240 V 0 a, Round up to next size per Art 240.4(B) Voc: 37.3 V deg F deg ------------------------------------------- Vmp: 30.7 V Record Low Temp: 32 0 Total voltage drop in AC conductors= .16 3. Conductor Sizina Der Art 690.8(B)(1) Isc: 8.47 A Max Average Hi Temp:j 0 82 28 Total voltage drop in AC and DC conductors= 0.63 a. Conductor must have 30 deg. C ampacity >= 125% of continuous Imp: 7.98 A Record Hi Temp:189 32 / current per Art 215.2(A)(1). Tvoc: -0.11532 V/deg C Tisc: 4.185 mA/deg C I b. Conductor must have (after corrections for conditions of use) >= String Type A and 2 Combined Strings Tvpe A Voc Correction Method: Manuf Tvoc Ita Branch Circuit Type A 1 way wire length: 0 continuous current per Table 310.15(8)(16). Power-One PVI-4.2-5 Voc Correction Factor: 11 strings per branch 1 11 strings per branch 2 12 TRINA SOLAR#TSM 245PC05 Inverter Min Vdc Input: 120 12 modules per series string 12 modules per series string c. Evaluate conductor temperature at terminations per Art 110.14(C). voc= 447.6 Min Vmp at Max Temp: 335.57 voc= 447.6 v Voc= 447.6 v p p Max Voc at Min Temp: 482.2 Ampacity of wire derated for conditions of termination must be >= vmp= 368.4 Inverter Max Vdc Input: 600 vmp= 368.4 v vmp= 368.4 V Isc= 8.47 = 8.47 A continuous current*1.25. All branch terminations are rated at 75' C Max String Size: 14 Isc= 8.47 A Isc min. Imp= 7.98 1-way wire length: 80 I Imp= 7.98 A Imp= 7.98 I A ------------------------------------------ Icont= 10.59 Art 690.8(A)(1) Icont= 10.59 A Icont= 10.59 A Art 690.8(A)(1) 4. OCP Sizina 1.a Conductor: AWG_10 I PV Wire 2.a Conductor 1: AWG_10 I PV Wire Conductor 2: I AWG_10 IPVVVire a. Round up to next size per Art 240.4(B) icont*1.25=(Amps) 13.23 I Conductor 1 Conductor 2 ------------------------------------------ 30 deg C ampacity= 401 Icont*1.25=(Amps) 13.23 13.23 5. Conductor Sizina Der Art 690.816)(1) 1.b Icont=(Amps) 10.59 30 deg C ampacity= 40 40 a. Conductor must have 30 deg. C ampacity >= 125% of continuous Start ampacity 40 b Icont=(Amps) 10.59 10.59 current per Art 215.2(A)(1). Temperature derate(%=F) 0.71 Start ampacity 40 40 Conduit fill derate(%=#) 1 Temperature derate(%=F) 0.82 0.82 b. Conductor must have (after corrections for conditions of use) >= Derated ampacity 28.4 Conduit fill derate(%=#) 0.8 0.8 per Table 310.15(B)(16). 1-C Derated ampacity 26.24 26.24 COntinUOUS Current p icont*1.25=(Amps) 13.23 1 2.c Term 1 Term 2 Ampacity 401 Temp table !75degC 1.d *1.25=(Amps) 13.23 c. Evaluate conductor temperature at terminations per Art 110.14(C). Icont*1.25=(Amps) 13.23 175degC 13.23 Ampacity of wire derated for conditions of termination must be >= OCP OCP Size= 1 15 ' _ Ampacity 35 .35 continuous current*1.25. All inverter output terminations are rated at 75' C. Inverter Type A Output 2.d OCP Size= 15 15 ------------------------------------------- Power-One PVI-4.2-S I 1 way wire length: 10 ft Combined Inverter Output 6. OCP Sizing_ icont= 1 20 JA Art 690.8(A)(1) Service Voltage= a. Round u to next size per Art 240.4 B 3.a icont*1.25=(Amps) 25 Art 690.8(6)(1) Total Inverter Power= 1 way wire length= 0 p p ( ) OCP Size= 291 Art 2400A) Icont=#of inverters*max inverter current Art 690.8(A)(1) 3.b Conductor:)AWG_10 THWN-2 af90 deg C:Table 310.16 Icont=(Amps) 7. Conductor Sizina Der Art 690.8(8)(1) Icont*1.25=(Amps) 25 4.a Icont*1.25=(Amps) I Art 690.8(B)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous Ic deg C ampacity s 40 OCP size= I 0.6(A) rU P,RTINO current per Art 215.2(A)(1). 3.c Icont=(Amps) 20 4.b Conductor: THWN g C:Table 310.1bt1ilding [)apartment ,,,: Start ampacity 40 Icont*1.25=(Amps) Q r;: b. Conductor must have (after corrections for conditions of use) >= Temperature derate(%=F) 0.91 30 deg Campacity= ; Conduit fill derate(%_#) 1 4.c Icont=(Amps) _ 2 2013 continuous current per Table 310.15(B)(16). Start ampacity Derated ampacity 36.4 Temperature derate(%=F) ITT l" !� 3.d Icont*1.25=(Amps) � / , .VED FOR CODE COMPLIANCE c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity /35 Conduit fill derate(%=#) n Ampacity of wire derated for conditions of termination must be >= Derated ampacity Review y 7 continuous current*1.25. All inverter output terminations are rated at 4.d Icont*1.25=(Amps) 75' C min. Ampacity PREMISE OWNER: AHJ: Cupertino DESCRIPTION: DESIGN: CONFIDENTIAL- THE CONTAINED SHALL NOT BEMUSED FOR THE """ JB-9501188 00 YOUNG, CHARLES YOUNG RESIDENCE SPETE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES � Solaitity.NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI (24) TRINA SOLAR # TSM-245PC05/PA05. 8 21690 ALCAZAR AVE 5.88 KW PV Array /,1 1 PART TO OTHERS OUTSIDE THE RECIPIENT'S PROJECT MANAGER: MOUNTING SYSTEM: CUPERTINO, CA 95014 fllY�J+/°�� ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clearview way San Mateo,CA THE SALE AND USE OF THE RESPECTIVE Comp SleekMount Type C PAGE NAME: SHEET- REV: DATE: 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: IN lER T:(650)638-1028 F:(650)638-1029 PERMISSION of SOLARCITY INC PPA (1' POWER-ONE # AURORA PVI-4.2-OUTD-S$M`�262669 ELECTRICAL CALCULATIONS PV 7 A 1/25/2013 (888)-SOL-Cnv(765-2489)www.solarcity.can CAUT-ION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 21690 Alcazar Ave INVERTER & AC DISCONNECT �LAR WTOVOLTAIC j )N ROOF �- UTILITY SERVICE PHOTOVOLTAIC BACK—FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS A/C DISCONNECT PER NEC 690.17 - OPERATING VOLTAGE = 240V MAX CURRENT = 20.83 A CUPERTINO Building Department JUN 1 2 2013 REVIEWED FOR CODE COMPLIANCE Reviewed By: 46; PREMISE OWNER: AHJ: Cupertino DESCRIPTION: DESIGN: ! drr CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER J B-9501188 00 SPETE �► ■ CONTAINED SHALL NOT BE USED FOR THE YOUNG, CHARLES YOUNG RESIDENCE .. ,. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES ��� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN I RESI (24) TRINA SOLAR 4 TSM-245PC05/PA05.18 21690 ALCAZAR AVE 5.88 KW PV Array 'sOf� 't PART TO OTHERS OUTSIDE THE RECIPIENT'S I _1_�. I 0 ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: MOUNTING SYSTEM: C U P E R TI N 0, C A 95014 4� ��/�i� 3055 Clearview Way San Mateo,CA THE SALE AND USE OF THE RESPECTIVE I Comp SleekMount Type C 9W2 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: T:(650)638-1028 R(650)638-1029 PERMISSION OF SOLARCITY INC. PAYMENT TYPE: IN TFR PPA 1 POWER-ONE # AURORA PVT-4.2-OUTD-S6y5942 6 2 6 6 9 SITE PLAN PLACARD PV 8 A 1/25/2013 (868)-SOL-CITY(765-2489)www.solarcity.can ` Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT MAXIMUM AC - A ■• WARNING Per Code: OPERATING CURRENT - ••-: Per Code CA Fire Guidelines MAXIMUM AC V 690.54 INVERTER OUTPUT NEC 690.64.B.7 OPERATING VOLTAGE CONNECTION Label • I • DO NOT RELOCATE THIS OVERCURRENT PHOTOVOLTAIC DC DEVICE Per Code: CE DISCONNECT 690.14.C.2 Label Location: -• PV SYSTEM Label DISCONNECT FOR UTILITY OPERATION WARNING .•- • • Code: MAXIMUM POWER A CEC 690.35(F) POINT CURRENT(Imp)_ - - THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE O BE USED WHEN MAXIMUM POWER- V CEC 690.53 UNGROUNDED AND INVERTERIS POINT VOLTAGE(Vmp) MAXIMUM SYSTEM Label Location: MAY BE ENERGIZED UNGROUNDED VOLTAGE(Voc)_V WARNING (AC) '' SHORT-CIRCUIT A Code: CEC CURRENT(Isc) ELECTRIC SHOCK HAZARD 690.17 DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label • • WARNING Per „` ELECTRICAL SHOCK HAZARD 690.17 Label DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND PHOTOVOLTAIC POINT OF (POI) LOAD SIDES MAY BE ENERGIZED INTERCONNECTION Per Code: IN THE OPEN POSITION WARNING: ELECTRIC SHOCK DC VOLTAGE IS HAZARD.DO NOT TOUCH 690.54; 690.17 CUPERTINO ALWAYS PRESENT WHEN TERMINALS.TERMINALS ON SOLAR MODULES ARE BOTH THE LINE AND LOAD SIDE EXPOSED TO SUNLIGHT MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. Building Department PV POWER SOURCE Label MAXIMUM AC A . OPERATING CURRENT - WARN I N G OPERAT NG VOU AGE _ V JUN 12 20113 Per Code: ELECTRIC SHOCK HAZARD 690.5(C) • • • Reviewed By: IF A GROUND FAULT IS INDICATED . , NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED ,•-I Location: (POI)Code: Per PHOTOVOLTAIC SYSTEM ••� •� � � �. CIRCUIT IS BACKFED (AC): AC Disconnect PHOTOVOLTAIC AC '• Conduit Per Code: (CB)-. Combiner Box DISCONNECT Distribution Label • • Disconnect CAUTION '•I) (IC): Interior Run Conduit DUAL POWER SOURCE Per ••' Inverter Integrated Disconnect SECOND SOURCE IS CEC 690.64.B.4 PHOTOVOLTAIC SYSTEM Load (M): Utility Meter '• Point of • • INFORMATION CONFIDENTIAL - THE O E i O• 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., • ON IN MOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, SC - CA Label Set EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE / ' SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSI OF SOLARCITY INC. I mono multi solutions TrI11Clmount II FOR PITCHED ROOF TSM-PC05/ PA05.18 mono multi solutions I ELECTRICAL DATA @ STC TSM-225 TSM-230 TSM-235 TSM-240 TSM-245 DIMENSIONS OF PV MODULE TSM-PCOS/PA05.18 PC/PA05.IS PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 Peak Power Watts-P-(Wp) 225 230 235 240 245 • oaA Tirinamoun t II 10 YEAR a" = Power Output Tolerance-Pranx ) 29.4 29.8 30A 30.4 30.7 � Maximum Power Voltage-Vnw(V) 29.4 29.8 30.1 30.4 30.7 PRODUCT WARRANTY FOR MODULE Maximum Power Cu Current-IMrr(A) 7.66 7.72 7.61 z69 7.98 Trinasolar AND MOUNTING SYSTEM _ Open Circuit voltage-Voc(V) 36.9 37.0 37.1 37.2 37.3 Short Circuit Current-Ise(A) 8.20 8.26 8.31 8.37 8.47 FOR PITCHED ROOF 5X - Module Efficiency qm(%) 13.7 14.1 14.4 14.7 15.0 FASTER TO INSTALL AL _jA Values al5tandord Test Conditions STC(Air Mass AM 1.5.Inadiance 1000W/m�.Cell Temperature 25°C). a ELECTRICAL DATA @ NOCT ULTRA LOW TSM-225 TSM-230 TSM-235 TSM-240 TSM-245 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 i Maximum Power(W) 164 168 172 175 178 RESISTANCE I L Maximum Power Voltage(V) 26.9 27.1 27.4 27.7 27.8 GROUND BOND CONNECTION / j e Maximum Power Current(A) 6.12 6.20 6.27 6.32 6.41 LOX BETTER THAN UL MINIMUM CRITERIA $ Open Circuit Voltage(V) 33.8 33.9 34.0 34.1 34.2 Short Circuit Current(A) 6.62 6.68 6.70 6.75 6.83 J/ - NOCT:Irradiance at 80OW/m'.Ambient Temperature 2(°C.Wind Speed IM/s. Back View MECHANICAL DATA Solar cells Multicrystalline 156 x 156mm IS inchesl I 1 Cell orientation 60 cells(6 x 10) '•;\ Module dimension 1650 x 992 x 40mm 164.95 x 39.05 x 1.57 inches) Weight 20.3kg(44.8 lb) Glass High transparency solar glass 3.2mm(0.13 inches) -� Frame Anodized aluminium alloy J-Box IF 65 rated A-A Cables/Connector Photovoltaic Technology cable 4.Omm'(0.006 inches'). 11 00m(43.3 inches),MC4/H4 I-V CURVES OF PV MODULE TSM-230PCO5/PAOSAS 9!° I000wrm' 8? TEMPERATURE RATINGS 19* Nominal Operating Cell 46°C(±2°C) ao 1, \ Temperature(NOCT) M Temperature Coefficient of PMnx -0.43%/°C 41 ioow/m' J Temperature Coefficient of Voc -0.32%/°C 3.° 2oow/m' 2a - - - _---- --------- Temperature Coefficient of Isc 0.047%/°C Im' SUITABLE FOR COMBINING PV MODULE EXPERTISE WITH A HIGHLY 0.. 0!' 10!" 20P' 301 401 MAXIMUM RATINGS ® INNOVATIVE MOUNTING SYSTEM SOLUTION. voltage[vJ i CUPERTINO COMPOSITION SHINGLE Operational Temperature 40-+g5°C Trina Solar is introducing Trinamount-the fastest,easiest and least Maximum System Voltage I OOOV DC(IEC)/600V Building Pepaftent expensive way to mount PV modules onto residential and commercial DC(UL) 4w 2 rooftops.With a series of drop-in and quarter-turn connections on a Max Series Fuse Rating 15A y CERTIFICATION JUN 12 20131 ® TRAPEZOIDAL METAL specialized module frame,this mounting solution installs up to S times faster than conventional mounting systems.Trinamount connects directly to the module frame,eliminating the need for long rails. E ®1 PV`YCLE J `LW�BS WARRANTY REVIEWED FOR CODE COMPLIANCE ® STANDING SEAM ROOF By drastically reducing the number of parts,cost of materials and 10 yearworkmanship warranty installation time,Trinamount offers the optimal solution for residential zs yea linear performance rta manes wa anfy Reviewed By: "" and commercial installations. w (Please refer to product warranty for details) F �OMPq� hq @fin` Trinasolarp/ Trinasolar CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. The power behind the panel eOMPNt� The power behind the panel C 2011 Trina Solot Limited.All rights reserved.Specifications included in this datasheet are subject to change without notice. I I i i I SolarCity SleekMountT"" - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules aesthetics while minimizing roof disruption and Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and •Interlock and grounding devices in system UL listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2 � mounting clamps, combined with the addition Seal pilot hole with roofing sealant of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 C to a more visually appealing system.SleekMount as"Grounding and Bonding System" Insert Comp Mount flashing under upper utilizes Zep Compatible TM modules with •Ground Zep UL and ETL listed to UL 467 as \,, layer of shingle strengthened frames that attach directly to grounding device >♦ Place Comp Mount centered Zep Solar standoffs,effectively eliminating the need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition \ ! Install lag pursuant to NDS Section 11.1.3 •Anodized components for corrosion resistance shingles are not required to be cut for this with sealing washer. system, allowing for minimal roof disturbance. •Applicable for vent spanning functions Secure Leveling Foot to the Comp Mount using machine Screw • Place module A Components B 5/16"Machine Screw Leveling Foot Lag Screw Comp Mount C Comp Mount Flashing D o E ® I II � I CUPERTINO ,.Q O/M_A) B �Eta O L , �ullding Department LISTED SolarC-t y January 2013 SOIN�Ity January 2013 OOWN JUN 12 2013 REVIEV EDD FOR CODE COMPLIANCE Reviewed By: A/L'"d� i �1 sower-oaeR UD M%C)l A R `!Renewable Ene1gy Solutions DATA ' ' ' ' ' ' ' Nominal Output Power W 3000 3600 4200 Maximum Output Power W 3000 3300** 3300** 3600 4000** 4000** 4200 4(M*' 4600** Rated Grid AC Voltage V 208 240 277 208 240 277 208 240 277 Input Side(DC) Number of Independent MPPT Channels 2 2 2 �I—�•0�� Maximum Usable Power for Each Channel W 2000 3000 3000 P Absolute Maximum Voltage(Vmax) V 600 600 600 + Start-Up Voltage(Vstart) V 200(adj.120-350) 200(adj.120-350) 200(adj.120-350) Full Power MPPT Voltage Range V 160-530 120-530 1 P Y I-3.6—T L Operating MPPT Voltage Range V 0.7xVstart-580 0.7zVstart-580 0.7xVstart- 580 ' Maximum Current(ldcmax)for both MPPT in Parallel A 20 32 32 `'I n T �T Maximum Usable Current per Channel A 10 16 16 P Y •^/ Maximum Short Circuit Current Limit per Channel A 125 20 20 NumberofWire Landing Terminals Per Channel 2 Pairs(Ion-5 version) 2 Pairs(Ion-S version) 2 Pairs(1on-S version) GENERAL SPECIFICATIONS Array Wiring Termination Terminal block,Pressure Clamp,AWG10-AWG4 Output Side(AC) OUTDOOR MODELS �.*aaa+ Split- Split- Split- Grid Connection Type 10/2W 0/3W 10/2W 10/2W 0/3W 10/2W 10/2W 0/3W 10/2W Adjustable Voltage Range(Vmin-Vmax) V 183-228 211-264 244304 183-228 211-264 244304 183-228 211-264 244304 Grid Frequency Hz 60 60 60 Adjustable Grid Frequency Range Hz 57-00.5 57.60.5 57-60.5 tr Maximum Current(lacmax) A.., 14.5 14.5 12 17.2 16 16 20 20 20 Power Factor >0.995 >0.995 >0.995 The mo st co m mo n residentia l i nverter is th e i d ea l size fo r a n avers ge- Total Harmonic Distortion At Rated Power % <2 <2 <2 sized family home. This family of single-phase string inverter - Grid Wiring Termination Type Terminal block,Pressure Clamp,AWGio-AWG4 complements the typical number of rooftop solar panels,allowing Protection Devices Input home-owners to get the most efficient energy harvesting for the Reverse Polarity Protection Yes Yes Yes sizeof the property.This rugged outdoor inverter has been designed Over-Voltage Protection Type Varistor,2 for each channel Varistor,2 for each channel Varistor,2 for each channel PV Array Ground Fault Detection Pre start-up Riso and dynamic GFDI(Requires Floating Arrays) as a completely sealed unit to withstand the harshest environmental Output conditions. Anti-Islanding Protection Meetrquirem/IEE1547 Meetsquirem/IEE1547 Meetsquirem/IEE1547 requirements requirements requirements Over-Voltage Protection Type Varistor,2(L,-L,/L,-G) Varlstor,2(Lr-L,/L,-G) Varlstor,2(Li-L,/L,-G) One of the key benefits of the Uno family of single-phase inverters * Maximum ACOCPD Rating A 20 20 15 25 20 20 25 25 25 is the dual input section to process two strings with independent Efficiency P P 9 P Maximum Efficiency % 96.9 97 97 MPPT especially useful for rooftop installations with two different CEC Efficiency % 96 96 96 orientations(ie East and West).The high speed MPPT offers real-time Operating Performance Stand-by Consumption W­ <8 <8 <8 power tracking and improved energy harvesting. + Nighttime consumption wR,Rs <0.6 <0.6 <0.6 Communication User-Interface 16 characters x 2lines LCD display The transformeriess operation gives the highest efficiency of up to Remote Monitoring(1xRS485incl.) AURORA-UNIVERSAL(opt.) 97.0%. The wide input voltage range makes the inverter suitable to Wired Local Monitoring(1xRS485 incl.) PVI-USB-RS485_232(opt.),PVI-DESKTOP(opt.) low power installations with reduced siring size. Wireless Local Monitoring PVI-DESKTOP(opt.)with PVI-RADIOMODULE(opt.) Environmental Ambient Air Operating Temperature Range °F(°C) -13 to+140(45 to+60)with -13 to+140(-25 to+60)with -13 to+140(-25 to+60)with � derating above 131(55) derating above 131(55) derating above 113(45) Ambient Air Storage Temperature Range °F(°C) -40 to 176(-40 to+80) -40 to 176(-40 to+80) -40 to 176(-40 to+80) Relative Humidity %RH 0-100 condensing 0-100 condensing 0-100 condensing Emission Level db A 1m <50 <50 <50 Acoustic Noise Eml I n 1 )@ - Maximum Operating Altitude without Derating ft(m) 6560(2000) 6560(2000) 6560(2000) Mechanical Specifications Enclosure rating NEMA 4X NEMA 4X NEMA 4X • Each inverter is set on specific rid codes which can be selected in the field cooling Natural Convection Natural Natural Convection P 9 Dimensions(HxWxD) in(mm) 33.8x12.8x8.7(859x325x222)-SVersion • Single phase output Weight Ib/(kg) <47.3(21.3)-5 version <47.3(21.3)-S version <47.3(21.3)-S version • Dual input sections with independent MPPT,allows optimal energy harvesting from two sub-arrays oriented in Mounting System Wall bracket size Wall bracket Trade size KOs:(tea x 12")and Trade size KOs:(tea x 12�and Trade size KOs:(tea x 1/2')and different directions Conduit Connections*** (2eax1-1/C 3 Places side,front, (2eax1-1/4'3 places side,front (2eax1-1/4'3 places side,front, i rear) rear) rear) • Wide input range DC Switch Rating-(Per Contact) AN 25/600 25/600 25/600 i • High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting Safety c Isolation Level Transformerless(Floating Array) Transformerless(Floating Array) Transformerless(Floating Array)• Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across Safety and EMC Standard UL 1741,CSA-C22.2N.107.1-01 UL1741,CSA-C22.2N.107.1-01 UL 1741,CSA-C22.2N.107.1-01 the entire input voltage and output power range Safety Approval <CSA., CSA,,, CSA,n • Outdoor enclosure for unrestricted use under any environmental conditions Standard Warranty years 1a 10 to I • Integrated DC disconnect switch in compliance with international Standards(-SVersion) Extended Warranty years 15&20 15&20 15&20 • RS-485 communication interface(for connection to laptop ordatalogger) Available Models Standard-Without DC Switch and Wiring Box PVI-3.0.OUTD-US PVI-3.6-0 PVM.2-OUTD-U//11 7./UPERTINO • Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP With DC Switch and Wiring Box PVF3.0.OUTD-5-U5 PVI-3.6-0 PVI.4.2-OUTD- S 'All data is subject to change without notice ;- Ilding Department ' `•Capability enabled at nominal AC voltage and with sufficient DC power available f4.' • • `••When equipped with optional DC Switch and Wring Box ' • JUN I REVIEWED FOR CODE COMPLIANCE Reviewed By: <� J OSA INTERNATIONAL Certificate of Compliance Certificate: 2096477 Master Contract: 173688 Project: 2439385 Date Issued: July 19,2011 Issued to: Power-One,Inc 740 Calle Plano Camarillo,CA 93012 USA Attention:Robert White The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C'and 'US'for Canada and US or with adjacent indicator 'US'for US only or without either indicator for Canada only. ® Rob-He Mpoock. Issued by: Rob Hempstock,AScT. C US PRODUCTS CLASS 531109 -POWER SUPPLIES-Distributed Generation Power Systems Equipment CLASS 531189 -POWER SUPPLIES-Distributed Generation-Power Systems Equipment -Certified to U.S.Standards Utility Interactive Inverter,Models PVI-4.2-OUTD-US,PVI-3.6-OUTD-US,PVI-3.0-OUTD-US,PVI4.2- OUTD-S-US,PVI-3.6-OUTD-S-US,PVI-3.0-OUTD-S-US,PVI4.2-OUTD-US-W,PVI-3.6-OUTD-US-W and PVI-3.0-OUTD-US-W;provided with two DC input channels,permanently connected. For details related to ratings,reference should be made to the CSA Certification Record,Appendix 1 or the Descriptive Report. APPLICABLE REOUIREMENTS CSA-C22.2 No.107.1-01 - General Use Power Supplies UL Std No. 1741-Second Edition - Inverters,Converters,Controllers and Interconnection System Equipment for Use With Distributed Energy Resources(January 28,20 10) CUPERTINO ' Building Department DQD 507 Rev.2009-09-01 Page:I �;. JUN 12 200 REVIEWED FOR CODE COMPLIANCE Reviewed 8y: ,,t�' CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 21690 ALCAZAR AVE CONTRACTOR:SOLARCITY PERMIT NO:13010144 OWNER'S NAME: YOUNG CHARLES C ET AL 3055 CLEARVIEW WAY DATE ISSUED:01/29/2013 OWNER'S PHONE: 6509262669 SAN MATEO,CA 94402 PHONE NO:(650)638-1028 ❑ LICENSED CONTRACTOR'S DECLARATION, JOB DESCRIPTION: RESIDENTIAL El COMMERCIAL❑ License Class Lic.# SOX9 `► 24 PANEL ROOF TOP FLUSH-MOUNTED PHOTOVOLTAIC . SYSTEM(5.88KV ) Contractor �} A . Date I _ I hereby affirm that I am licen d under the provisions of Chapte 9 REVISION#2-CHANGE MODULE FROM TRINA SOLAR (commencing with Section 7000 of Division 3 of the Business&Professions #TSM-240 TO TRINA SOLAR#TSM-245,5.76 KW-ISSD OTC Code and that my license is in full force and effect. 8/5/2013 I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the Ajhave rformance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$25000 and will maintain Worker's Compensation Insurance, ction 3700 of the Labor Code,for the performance of rch this APN Number:35719097.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITIIIN 180 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 D FROM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the Issued b Date: / granting of this permit. Additionally,the applicant understands and will comply y' with all non-pop' source regulatio er the Cupertino Municipal Code,Section 9.18. RE-ROOFS: Signature Date o I 1, All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE, construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 912 and the declarations: Health&Safety Code,Section 25532(x)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino icipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sec' 505,255 ,a 255 4. — Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized agent ate: �/J permit is issued. I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. It after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 CUPERTINO (408)777-3228•FAX(408)777-3333•buildinc0a.cuDertino.orp. ❑NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION/TI t Ley REVISION/DEFERRED ORIGINAL PERMIT# PROJECT ADDRESS ,/�` l0 1 �`C 0 czOIr ,/� _ , bb I APN# OWNERNAME `� p(m) q�(¢ (J�.WT 1 I M L n/v��J'0&IaC- .1 Jm J Ord= C,-L STREET ADDRESS �1 r_ 1 �p CIT STATEfZIP , - " r FAX fff�����t d 1,� rat I �' o)r r\() J I CONTACT NAME \W./((,�,n ®� n, PH�011 t �� I EIv(Ag41 n (Z �,,, ct'Uri ` STREET ADDRESS �v�.l (� 6(�1 I Crm - IP/�/I p�t e�O(1 FAX ❑OWNER ❑ OWNER-BUILDER ❑ OWNERAGENT ❑ CONTRACTOR CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑TENANT CONTRACTOR NAME G�'lp �,, I LICENSE NUMBER I LICENSE TYPE BUS.LIC# COMPANY NAME VV E-MAIL n i,.\ " "1 FAX STREET ADDRESS CITY,STATE,ZIP S I^ � PHONE ARCHITECT/ENGINEER NAME LICENSE NUMBER �U BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS /1 /�CITY,STATE,ZIP PHONE V DESCRIPTION OF WORK ifs± ` ice- , J c� Y i o0� 240 mo" 1rc4md w � "I U I fir►nq 2-TS . S•1 b 1:�cN ) vow EXISTING USE PROPOSED USE I CONSTR.TYPE I #STORIES USE TYPE OCC. SQ.FT. VALUATION($) EG NEW FLOOR �O AL AREA I I G A BATHROOM I KITCHEN OTHER REMODEL AREA REMODEL AREA REMODEL AREA PORCH AREA I DECK AREA I TOTAL DECK/PORCH AREA I GARAGE AREA: ❑❑DErACH #DWELLING UNITS: I IS A SECOND UNIT ❑YES SECOND STORY [:]YES BEING ADDED? ❑NO ADDITION? ❑NO PRE-APPLICATION ❑YES IF YES,PROVIDE COPY OF IS THE BLDG AN ❑YES izeent I TOT VALUATION: PLANNING APPL# ❑NO PLANNING APPROVAL LETTER EICHLER HOME? ❑NO 1-f f By my signature below,I certify to each of the following: I am the property owner or autto act on the pr operty owner's behalf. I have read this application and the information I have rovided is correct have read the Description of fy it is accurate. I agree to comply with all applicable local ordinances and state laws relating t g constmctio . auth ' e representatives of Cupertino to enter the abo ide fled p operty for inspection purposes. Signature of Applicant/Agent: Date: I SUPPLEMENTAL INFORMATION REQUIRED PLAN C K TYPE ROUTING SLIP New SFD or Multifamily dwellings: Apply for demolition permit for OVER-THE COUNTER ❑ BUILDING PLAN REVIEW existing building(s). Demolition permit is required prior to issuance of building permit for new building. ❑ EXPRESS ❑ PLANNING PLAN REVIEW _Commercial Bldgs: Provide a completed Hazardous Materials Disclosure El STANDARD El PUBLIC WORKS form if any Hazardous Materials are being used as part of this project. ❑ LARGE ❑ FIRE DEPT _Copy of Planning Approval Letter or Meeting with Planning prior to ❑ MAJOR ❑ SANITARY SEWER DISTRICT submittal of Building Permit application. ❑ ENVIRONMENTAL HEALTH BldgApp_2011.doc revised 06121111 I ABBREVIATIONS ELECTRICAL NOTES INDEX LICENSE JURISDICTION NOTES 1. WHERE ALL TERMINALS OF THE DISCONNECTING PV1 COVER SHEET CA # 888104 A AMPERE MEANS MAY BE ENERGIZED IN THE OPEN PV2 SITE PLAN C-46, C-10 AC ALTERNATING CURRENT POSITION, A SIGN WILL BE PROVIDED WARNING PV3 STRUCTURAL VIEWS ® BLDG BUILDING OF THE HAZARDS PER ART. 690.17. PV4 STRUCTURAL VIEWS CONC CONCRETE 2. EACH UNGROUNDED CONDUCTOR OF THE PV5 UPLIFT CALCULATIONS C COMBINER BOX MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PV6 THREE LINE DIAGRAM D DISTRIBUTION PANEL BY PHASE AND SYSTEM PER ART. 210.5. PV7 ELECTRICAL CALCULATIONS DC DIRECT CURRENT 3. A NATIONALLY—RECOGNIZED TESTING PV8 SITE PLAN PLACARD EGC EQUIPMENT GROUNDING CONDUCTOR LABORATORY SHALL LIST ALL EQUIPMENT IN CUTSHEETS ATTACHED (E) EXISTING COMPLIANCE WITH ART. 110.3. EMT ELECTRICAL METALLIC TUBING 4. CIRCUITS OVER 250V TO GROUND SHALL G SOLAR GUARD METER COMPLY WITH ART. 250.97, 250.92(B) CUTSHEETS ATTACHED GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR 5. DC CONDUCTORS EITHER DO NOT ENTER GND GROUND BUILDING OR ARE RUN IN METALLIC RACEWAYS GENERAL NOTES HDG HOT DIPPED GALVANIZED OR ENCLOSURES TO THE FIRST ACCESSIBLE DC Installing 24—roof top flish—mounted panels (5.88kW). I CURRENT DISCONNECTING MEANS PER ART. 690.31(E). Standard breaker tie in (30A) at main panel. Imp CURRENT AT MAX POWER 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN 1. THIS SYSTEM IS GRID INTERTIED VIA A Inverter and AC disconnect to go in garage. INVS INVERTERS RELIEF AT ALL ENTRY INTO BOXES AS UL—LISTED POWER—CONDITIONING INVERTER. Isc SHORT CIRCUIT CURRENT REQUIRED BY UL LISTING. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. kVA KILOVOLT AMPERE 7. MODULE FRAMES SHALL BE GROUNDED AT THE 3. PHOTOVOLTAIC SOURCE AND INPUT CIRCUITS AND kW KILOWATT UL—LISTED LOCATION PROVIDED BY THE INVERTER INPUT CIRCUIT ARE UNGROUNDED. LBW LOAD BEARING WALL MANUFACTURER USING UL LISTED GROUNDING 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED MIN MINIMUM HARDWARE. 5. ALL WORK TO BE DONE TO 2010 CALIFORNIA MIR MIRROR 8. ALL EXPOSED METAL PARTS (MODULE FRAMES, BUILDING CODE. 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE ' `_ -` ,¢ (N) NEW RAIL, BOXES, ETC.) SHALL BE GROUNDED USING 2008 NATIONAL ELECTRIC CODE AS AMENDED BY - p NEC NATIONAL ELECTRIC CODE UL LISTED LAY—IN LUGS LISTED FOR THE = . NIC NOT IN CONTRACT PURPOSE. POSTS SHALL BE MADE THE 2010 CALIFORNIA ELECTRIC CODE. w NTS NOT TO SCALE ELECTRICALLY CONTINUOUS WITH ATTACHED OC ON CENTER RAIL. P PANEL BOARD 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE PL PROPERTY LINES BONDED WITH EQUIPMENT GROUND CONDUCTORS PV PHOTOVOLTAIC AND GROUNDED AT THE MAIN ELECTRIC PANEL. PVC POLYVINYL CHLORIDE 10. THE DC GROUNDING ELECTRODE CONDUCTOR VICINITY MAP S SUBPANEL SHALL BE SIZED ACCORDING TO ART. SCH SCHEDULE 250.166(8) & 690.47. SS STAINLESS STEEL CUPERTINO SSD SEE STRUCTURAL DRAWINGS - STC STANDARD TESTING CONDITIONS '« Building p�p�rtment SWH SOLAR WATER HEATER TYP TYPICAL AUG O 5 2013 UON UNLESS OTHERWISE NOTED UPS UNINTERRUPTIBLE POWER SUPPLY W/ VOLT � REVIEWED FOR CODE CO��M,/P�I_VARICE Vmp VOLTAGE AT MAX POWER Reviewed By, A�a Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTIGHT « REV BY DATE COMMENTS A WL 6/14 Simply switched inverter to Power --. One 4.2, nothing else changes, thank you PREMISE OWNER: AHk Cupertino DESCRIPTION: DESIGN: �%kj'j CONTAINED SHALL NOT BE USED FOR THE NUMBER: JB-9501188 00 YOUNG, CHARLES YOUNG RESIDENCE SPETE �- -;�WSolaitity. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET- NODULES NO SHALL IT BE DISCLOSED IN WHOLE OR IN RESI (241 TRINA SOLAR 4 TSM-240PC05/PAO5.18 21690 INO, C R AVE 5.76 KW PV Array 11 1 I PART TO OTHERS OUTSIDE THE RECIPIENT'S PRUCT MANAGER: MOUNTING SYSTEM: CUPERTINO, CA 95014 (l�/� -�' ORGANIZATION,EXCEPT IN CONNECTION WITH 3055 Clearview Way San Mateo,CA THE SALE AND USE OF THE RESPECTIVE Comp SleekMount Type C PAGE NAME: SHEET: REV: DATE: 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: IN TER 262669 PV 1 B / T:(650)638-1028 89)w)www.solarcity.com PERMISSION OF SOLARCITY INC. PPA (1� POWER—ONE # AURORA PVI-4.2—OUTD—S ♦ COVER SHEET 1 25 2013 (888)-SOT--CITY(765-2489)www.solarcity.can ` PITCH: 27 ARRAY PITCH:27 I MP1 AZIMUTH: 181 ARRAY AZIMUTH: 181 I I I 21690 Alcazar Ave i MATERIAL: Comp Shingle : One Story PITCH: 27 ARRAY PITCH:27 MP2 AZIMUTH:270 ARRAY AZIMUTH: 270 MATERIAL:Comp Shingle STORY: Two Storm I I I I I I I , I , I , y Front Of House I I I CUPERTINO Building Department ID AUG 0 5 Z013 PV4 REVIEWED FOR CODE COMPLIANCE , I I I Reviewed BY: ' LEGEND O i Inv`' I Q (E) UTILITY METER & WARNING LABEL OPV4 AC INVERTER W/ INTEGRATED DC DISCO S'to PL Ins & WARNING LABELS -un-tock�a C,'tectFencel _ N © DC DISCONNECT & WARNING LABELS AC DISCONNECT & WARNING LABELS c ❑� � JUNCTION BOX Q DC COMBINER BOX & WARNING 10'to PL Q DISTRIBUTION PANEL & WARNING LG LOAD CENTER & WARNING LABELS Flashing will be painted to Y OB match exterior. DEDICATED PV SYSTEM METER 0 Total array area: 430 CONDUIT RUN ON EXTERIOR Total roof area: 1500 sq. ft. CONDUIT RUN ON INTERIOR M131 Total array area is 30% of — GATE/FENCE roof area. --- INTERIOR EQUIPMENT A SITE PLAN N PV3 20'to PL Scale: 1/8" = 1' W E 0 1' 8' , 16' L®I Jill, �'I.dlll.l S JB-9501188 00 (PREMISE OWNER: AHD Cupertino DESCRIPTION: DESIGN: bb8,� II CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER SPETE CONTAINED SHALL NOT BE USED FOR THE YOUNG, CHARLES YOUNG RESIDENCE ':.,,,• BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: II NOR SHALL IT BE DISCLOSED IN wLIaE OR IN REST (241 TRINA SOLAR # TSM-240PC05/PA05.18 21690 ALCAZAR AVE 5.76 KW PV Array SDIa ity PART IZ OTHERS OUTSIDE THE RECIPIENT'S PROJECT MANAGER: MOUNTING SYSTEM: CUPERTINO, CA 95014 ORGANIZATION,EXCEPT IN CONNECTION WITH 3055 Clearview way San Mateo,CA THE SALE AND USE OF THE RESPECTIVE Comp SleekMount Type C PACE NAME: SHEET- REV: DATE: 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: RIVE TER; T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. PPA (1r POWER—ONE # AURORA PVI-4.2—OUTD—S6 262669 SITE PLAN PV 2 B 1/25/2013 (888)-SOL-CrY(765-2489)www.solarcity.com _ (E) 2x8 RAFTER 0 24" 0.C. S i (E) 2x12 RIDGE BOARD (E) 2x6 d (E) LBW 2' (E) 2x8 RAFTERS '-6' T-7" -3" @ 24" SPACING (E) LBW RAFTER: 2x8 FRONT VIEW O F M P I SUPPORT: 2x8, 2x12, 2x6 OB MAX SPAN: 8'-7" SCALE: 1/2" = 1' A SIDE VIEW OF MPI SCALE: 1/4" = 1' PV MODULE " BOLT WITH LOCK & INSTALLATION ORDER FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. - (4) I (2)1 ZEP COMP MOUNT C POLYURETHANE SEALANT. ZEP FLASHING C (3) (3)I INSERT FLASHING. CUPERTINO Building Department (E) COMP. SHINGLE (1) (4)I PLACE MOUNT. AUG 05 2013 (E) ROOF DECKING V� (2) V INSTALL LAG BOLT WITH " LAG BOLT WITH (5) C(5)1 SEALING WASHER. REV1E%jq-r_D FCR CODE CONI/F�'l-IA�CE a Z4 SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES C� INSTALL LEVELING FOOT WITH (6) BOLT & WASHERS. Previewed BY (E) RAFTER Sol STANDOFF Scale: 1 1/2" = 1' PREMISE OWNER: M1. Cupertino DESCRIPTION: DESIGN: ��/e CONTAINED SHALL NOT INFORMATION FOR THE I JOB NUMBER: J B-9501188 00 YOUNG, CHARLES YOUNG RESIDENCE I SPETE ;��_' BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES:- ' ' So I a rC ity. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN I RESI (24) TRINA SOLAR # TSM-240PCO5/PA05.18 21690 ALCAZAR AVE 5.76 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS PRUCT MANAGER: MOUNTRG SYSTEM: CU P ER TI N O, CA 95014 ORGANIZATION, EXCEPT IN CONNECTION WT I .✓ .-�' 3055 Clearview Way San Mateo,CA THE SALE AND USE OF THE RESPECTIVE Comp SleekMount Type C PAGE NAME: SHEET: REV: DATE 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE IN TER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. I PPA (1� POWER—ONE # AURORA PVI-4.2—OUTD—S6�262669 STRUCTURAL VIEWS PV 3 B 1/25/2013 (888)-SOL-CITY(765-2489)www.solarcty.corn a (E) 2x6 RAFTER •� S� 0 24" O.C. S2 (E) 2x8 RIDGE BOARD (E) 2x6 a t (E) 2x6 RAFTERS -8" 0'-1" ,• 31_ 11--------/ (E) 2x6 CEILING JOIST 0 24" 0.C. @ 24" SPACING (E) LBW (E) LBW RAFTER: 2x6 SUPPORT: 2x6, 2x8 FRONT VIEW OF M P2 MAX SPAN: 9'-1" D SCALE: 1/2" = 1' C SIDE VIEW OF MP2 SCALE: 1/4" = 1' PV MODULE " BOLT WITH LOCK & INSTALLATION ORDER FENDER WASHERS LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT (6) HOLE. (4) I (2)I SEAL PILOT HOLE WITH ZEP COMP MOUNT C / POLYURETHANE SEALANT. ZEP FLASHING C (3) (3)I INSERT FLASHING. (E) COMP. SHINGLE N (4)I PLACE MOUNT. CUPERTINO (1) I I I L De artment (E) ROOF DECKING V� (2) V Building P (5)I INSTALL LAG BOLT WITH " LAG BOLT WITH (5) SEALING WASHER. o A:OG 05 2013 SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES (6)1 INSTALL LEVELING FOOT WITH (E) RAFTER BOLT & WASHERS. R.EViEVVcL i=C)R CODE COtViPL1ANCE STANDOFF Reviewed By= S02Scale: 1 1/2" = 1' PREMISE OYMER: AHJ: Cupertino DESCRIPTION: DESIGN: `b CONTAINED SHALL NOT INFORMATION HEREIN USED FOR THE JDB NUMBER: J B-9501188 00 YOUNG, CHARLES YOUNG RESIDENCE SPETE �� i �'SolarCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI (24) TRINA SOLAR # TSM-240PC05/PA05. 8 21690 ALCAZAR AVE 5.76 KW PV Array a PART IZ OTHERS OUTSIDE THE RECIPIENT'S PROTECT MANAGER: MOUNTING SYSTEM: CU P ER TI N 0, CA 95014 (1101 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clearview Way San Mateo,CA THE SALE AND USE OF THE RESPECTIVE Comp SleekMount Type C PAGE NAME: SHEET: REV: DATE 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE IN TER: 262669 PV 4 B / T:(650)638-1028 F:(650)638-1029 PERMISSION of SOLARCITY INC. I PPA (1� POWER—ONE # AURORA PVI-4.2—OUTD—S STRUCTURAL VIEWS 1 25 2013 (888)-SOL-Cm(765-2469)www.solarcity.com ` UPLIFT CALCULATIONS olrl SolarCity SleekMounfi TM Yerskill x:4:1._ Plrq,�I�ct L.rfotltotl► , ,. 9yslk d Nrf `�i ifo ioa del' . 'Y�t a a�+�latlad Imo t3ecii - " I -ty II PV System Type SOfarCity SfeekMount'" PV't�lodl:de Ti'tna 5p�t T5Nt-2.4SP Total Number of Modules 24 i*oofing,M;3tertal Cct4 A-0of Number of Layers(Comp Roo_fs Only) 1 Tile�tete�f(`i'!la tsTfi�iLty) �NA, Roof Slope 270 $ hinge' s$' 1Vp PV Module_Orientation Landscape and Portrait PV Module Width 5.4 ft Total Square.Feet of Array 423 sf Exposure Category Section 6.5.6.3 Least Horizontal Dimension of Building LHD Mean Roof Height h 15 ft Section 6.2 ,F Wind Pressure Up sf} p(up) -10.0 -17.4 -27.0 •W sr Y)iYF-, - �'. - -- {ys.c"—_ a:s�^ w::'3i: �k?; ::�t;. ...:r v.�.-, __ Building Department n9 Maximum Allowed Cantilever Landscape 24" 24" 24" . AUG 0 5 2013 111 TC$6it iTff fret.ufary;�4rea Trlst 20 sf 0`0 1- eirt PV Assembly Dead Load WPV 3 psf 3 psi 3 psF REVIEWED FOR CODE COMPLIANCE DLPV kL �$q Ibs 5p Ibs. 59':tbS.; Sy: e412W @ WLUP-0.6 DLPV TCL -160 Ibs -304 Ibs -492 Ibs {I Attachitient Eplift:CapacttY Taliaw 7.:Ibs.: psi tbs G7 tfis• TCLfTallDw DCRLand 25.1% 47.7% 77.2% PREMISE OWNER: AHJ Cupertino DESCRIPTION: DESIGN: CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER J B-9501188 00 SPETE �• CONTAINED SHALL NOT BE USED FOR THE I YOUNG, CHARLES YOUNG RESIDENCE SolarCity.BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES /�NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI (24) TRINA SOLAR # TSM-240PC105/PA05. s 21690 ALCAZAR AVE 5.76 KW PV Array QJI-- I PART TO OTHERS OUTSIDE THE RECIPIENTS PROJECT MANAGER MOUNTING SYSTEM: CUPERTINO, CA 95014 �ORGA NIZATION,EXCEPT IN CONNECTION WITH 3055 Clearview way San Mateo,CA THE SALE AND USE OF THE RESPECTIVE Comp SleekMount Type C PAGE NAME: SHEET: REM: DATE 94402 SOLARCIY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE IN TER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOARCITY INC. PPA �1' POWER—ONE # AURORA PVT-4.2—OUTD—S6y5�1�262669 UPLIFT CALCULATIONS PV 5 B 1�25�2013 (888)-SOL-CIfY(765-2489)www.solarcity.com _ GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD (E) 200A MAIN SERVICE PANEL Inv 1: DC Ungrounded INV 1—(i)POWER–ONE#AURORA PV14A590M–S–US–Z "—(24)TRINA SOLAR#TSM-240PCO5/PAO5.18 CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP Multiple Main Breakers (6 or fewer) Inverter a2oow,zaov, ssr. PV Module –2011); 24ow,2ttw PTG,Black Frame C-46, C-10 Panel Number:Cutler—Hammer INV 2 Vpmax:30.4 Meter Number:1006679880 *MODULE CURRENT RATINGS ARE SHOWN AS Isc AND Imp IN INV 3 THE DC STRINGS IDENTIFIER OF THE SINGLE LINE DIAGRAM. MAIN SERVICE PANEL Inverter 1 IND B CUTLER—HAMMER 1 Disconnect (3 POWER—ONE DC+DO NOT ADJUST MIN.ACTIVATION V LTAGE AURORA PVI-4.2—OUTD—S—US—Z I I Dc-I I p 1 String(s)Of 12 On MP 2 --—— -- — EG --- . (E) LOADS A –––––––– —––––––– Ll E0 _♦ \� I L2 GFP/GFCI I (WIT I I N � DC- 1 2 DC+DO NOT ADJUST MIN.ACTIVATION V LTAGE Z5A�2P ———— GN _EGC/____ DC+ r ---------------------------------- GEC I DC- A l �--- DC- — — EG ----SStrin9(s)Cff120nMP1— B I GND --- EGC -- ————————————————————— --—————— ——— I I 1 (1)Conduit Kit; 3/4'EMT N 1 I I EGC/GEC z z _-- GEC TO 120/240V l SINGLE PHASE 1 UTILITY SERVICE I I II l l I I CUPERTINO Building Department . .� AUG 0 5 2013 POI (I)CUTLER–HAMMER#BR225 PV BACKFEED BREAKER (t)CUTLER–HAMMER#DG221URB A C REVIEWED FOR CODE COMPLIANL;t. DC Breaker. 25A/ j 2 Spaces ' ` I Disconnect; 30A,24OVoc,Non–FuslNe,IJEMA 3R A —0)Ground Rod 5I -V!copper —(1)CUTLER–HAMMER#DG030NB ,y, /o, ed.la Ground/Neutrd Kit; 30A,General Duty(DG) Reviewy. �(1)AWG#10,THWN-2,Block (2)AWG#l0,PV WIRE,Black Voc =446.4 VDC Isc =8.37 AD O (1)AWG#10,THWN-2,Red ( 1 1 (t)AWG#10,Solid Bare CopperEGC Vmp =364.8 VDC Imp=7.89 ADC ICI (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=20 AAC . . . .. . . ._ .{t)Conduit Kit;.2, 3/4'.EMT. . . . . . . . . . ... —{1)AWG#8,,THAN- ,Green, . EGC/GEC,-(1)Conduit,Kit;.3/4'EMT_ ... . . . .. (2)AWG#1 Vo 0,PV WIRE,Black c =446.4 VDC Isc =8.37 ADC O § (1)AWG 110,Solid Bare CopperEGC Vmp =364.8 VDC Imp=7.89 ADC (1)Conduit Kit:.3/.4�.EMT. . .. .. .. .. . . . ... . . .. . . . . . . .. .. . . . . .. .. CONFIDENTIAL– THE INFORMATION HEREIN JOB NUMBER PREMISE OWNER W. Cupertino DESCRIPTION: DESIGN: `t,Ito/01 CONTAINED SHALL NOT BE USED FOR THE I J B-9501188 00 YOUNG, CHARLES YOUNG RESIDENCE I SPETE -0. . BENEFIT LL ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES ,I' SolarC�ty NOR SHALL IT BE DISCLOSED IN WHOLE OR IN I REST (24) TRINA SOLAR ;� TSM-24oPCO5/PADS. s 21690 ALCAZAR AVE 5.76 KW PV Array o PART TO OTHERS OUTSIDE THE RECIPIENT'S PROJECT MANAGER: MOUNTING SYSTEM: CUPERTINO, CA 95014 I +� ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clearview Way San Mateo,CA THE SALE AND USE OF THE RESPECTIVE Comp SleekMount Type C PAGE NAME: SHEET: �! REV: DAIS: 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: IN lER 262669 I P V 6 B / / T:(650)638-1028 R(650)638-1029 PERMISSION OF SOLARCITY INC. PPA POWER—ONE # AURORA PVT-4.2—OUTD—S THREE LINE DIAGRAM 1 25 2013 (888)-SOL-CrY(765-2489)www.solarcity.com ` CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 21690 Alcazar Ave INVERTER do AC DISCONNECT 301.AR 'HOTOVOLTAIC )N ROOF X X - - �- UTIUTY -- - SERVICE CUPERTINO PHOTOVOLTAIC BACK—FED CIRCUIT BREAKER IN FAIN ELECTRICAL PANEL IS Building DePartment A/C DISCONNECT PER NEC 690.17 AUG 0 5 200 - OPERATING VOLTAGE = 240V MAX CURRENT = 20.83 A REVIEWED FOR CODE COMPLIANCE Reviewed By: CONFIDENTIAL— THE PREMISE OWNER AHJ: Cupertino DESCRIPTION: DESIGN: CONTAINED SHALL NOTJBERUSED ORTHE 1DB N0"' J B-9501188 00 YOUNG, CHARLES YOUNG RESIDENCE SPETE �: = NOR SHALL LL ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: /���� SOfa�'t� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN REST (24) TRINA SOLAR 4 TsM-240PCO5/PA05.18 21690 ALCAZAR AVE 5.76 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENT'S PROJECT MANAGER: MOUNTING SYSTEM: CUPERTINO CA 95014 ►lf l.r�_�► ORGANIZATION, EXCEPT IN CONNECTION WITH ' 3055 Clearview Way San Mateo,CA THE SALE AND USE OF THE RESPECTIVE Comp SleekMount Type C PAGE NAME: SHEET: REV: DATE: 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: IN 1ER 262669 PV Q B / / T:(650)638-1028 R(650)638-1029 PERMISSION OF SOLARCITY INC. PPA (1' POWER—ONE # AURORA PVI-4.2—OUTD—S SITE PLAN PLACARD V U 1 25 2013 (888)-SOL-CrY(765-2489)www.solarcity.com Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT •• CAUTION - Code: 11113 Code: DUAL POWER SOURCE Code: _ 690.54 SECOND SOURCE IS 690.64.B.4 PHOTOVOLTAIC SYSTEM Label PH Me OTLTAIC D (DC DISNNECT Per Code: CE 690.14.C.2 Label Location: Label Location: PV SYSTEM •' WARNING Code: DISCONNECT FOR UTILITY OPERATION ELECTRIC SHOCK HAZARD 690.35(F) Label o o THE DC CONDUCTORS OF THIS TO BE USED WHEN PHOTOVOLTAIC SYSTEM ARE POINT CURREN� (DC) Code: MAY BEO ENDERGIZED INVERTERIS MAXIMUM POWER- V CEC 690.53 POINT VOLTAGE(Vmp) MAXIOLTAGESVoc)_V Label Location: SHORT-CIRCUIT WARNING Per Code: CURRENT(Isc) A ELECTRIC SHOCK HAZARD 690.17 DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label • • WARNING ' P er ..- ELECTRICALSHOCK HAZARD DO NOT TOUCH TERMINALS 690.17 Label • a ' TERMINALS ON BOTH LINE AND WARNING •' LOAD SIDES MAY BE ENERGIZED Per Code: INTHE OPEN POSITION INVERTER OUTPUT DC VOLTAGE IS CONNECTION 690.64.13.7 CUPERTINO ALWAYS PRESENT WHEN DO NOT RELOCATE wa SOLAR MODULES ARE THIS OVERCURRENT Building Department EXPOSED TO SUNLIGHT DEVICE \��; AUG 0 5 2013 Label Location: Label Location: REVIEWED FOR CODE COMPLIANCE WARNING (POI)• _ Reviewed INTERCONNECTION •_ - ELECTRIC SHOCK HAZARD 690.5(C) 1NARNING: ELECTRIC SHOCK . 690.17 IF A GROUND FAULT IS INDICATED HAZARD. DO NOT TOUCH NORMALLY GROUNDED TERMINALS.TERMINALS ON CONDUCTORS MAY BE BOTH THE LINE AND LOAD SIDE UNGROUNDED AND ENERGIZED MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE Label Location: MAXIMUM AC A OPERATING CURRENT Disconnect PHOTOVOLTAIC AC (AC) (PO MAXIMUM AC - Conduit DISCONNECT Per Code: OPERATING VOLTAGE V Combiner ;• CEC 690.14.C.2 . Distribution DC Disconnect Conduit(IC): Interior Run Label Location: (INV): Inverter With Integrated DC Disconnect CAUTION •' Center Per Code: Meter PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED 690.64.13.4 Point of Interconnection INFORMATION CONFIDENTIAL- THE FOR THE BENEFIT OF ANYONE EXCEPT « DISCLOSED "0 CONNECTION IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, T:(650)EXCEPT IN SoiarCity SOLARCITY EQUIPMENT, VATHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. mono multi solutions Trlfilamount II FOR PITCHED ROOF TSM-PC05/ PA05.18 mono multi solutions ELECTRICAL DATA @ STC TSM-225 TSM-230 TSM-235 TSM-240 TSM-245 DIMENSIONS OF PV MODULE TSM-PCO5/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 Peak Power Watts-P-x(Wp) 225 230 235 240 $45 • 93R v � Power Output Tolerance-Pnust(�) 0/+3 '0/+3 0/+3 0/+3 0/+3 t I I 10 YEAR ux nDevz Maximum Power Voltage-V-IV) 29.4 29.8 30.1 30.4 30.7 Trinamoun PRODUCT WARRANTY FOR MODULE ! �� Maximum Power Current-IrwP(A(A) 7.66 7.72 7.81 7.89 7.98 byTrinasolar AND MOUNTING SYSTEM Open Circuit Voltage-Voc(V) 36.9 37.0 37.1 37.2 37.3 \ Short Circuit Current-Isc(A) 8.20 8.26 8.31 8.37 8.47 FOR PITCHED ROOF 5X - Module Efficiency rtm(%) 13.7 14.1 14.4 14.7 15.0 FASTER TO INSTALL AL JA Values at Standard Test Conditions STC(Air Mass AM 1.5,Irradiance 1000W/m',Cell Temperature 25°C). ULTRA LOW a ELECTRICAL DATA @ NOCT TSM-225 TSM-230 TSM-235 TSM-240 TSM-245 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 RESISTANCE Maximum Power Vol 164 27. 272 175 178 I l- Maximum Power Voltage(V) 26.9 27.1 �27.4 27.7 27.8 GROUND BOND CONNECTION .PF" 3 _ Maximum Power Current(A) 6.12 6.20 6.27 6.32 6.41 10X BETTER THAN UL MINIMUM CRITERIA Open Circuit Voltage(V) 33.8 33.9 34.0 34.1 34.2 f "i01E �t Short Circuit Current(A) 6.62 6.68 6.70 6.75 6.83 I ien NOCT:Irradiance at BOOW/m'.Ambient Temperature 20°C,Wind Speed lM/s. Back View MECHANICAL DATA Solar cells MOlficrystalline 156 x 156mm(6 inches) F� Cell orientation 60 cells(6 x 10) Module dimension 1650 x 992 x 40mm(64.95 x 39.05 x 1.57 inches) Weight - 20.3kg 144.5 Ib) ° Glass High transparency solar glass 3.2mm(0.13 inches) ,frame ,_ {Anpdizeaalufilniuiir;atloy J Box IP 65 rated A-A Cables/conhector' }!r.Photovoltaic TechnologK cable 4­6mn'4 10 OOb lnche5� I-V CURVES OF PV MODULE TSM-23OPCOS/PA05.18 9?P 1 lomw/m0 8- I TEMPERATURE RATINGS U�ERTINlO 7u0 I eww/m- +d Nominal Operating Cell ent a'6°D eoov//m, Temperature(NOCT) Building Depait�n 'in" e ��wl,}lof4 i t kh 7 U 400 I.4aow/m' _ Temperature Coefficient of Voc ;, , AUG 0 5 2013 c� 3.0J 12DDW/m° 1'n - c_�1, t " . SUITABLE FOR COMBINING PV MODULE EXPERTISE WITH A HIGHLY o� ���, ��: FOPS CODE COMPLIANCE INNOVATIVE MOUNTING SYSTEM SOLUTION. 1°� 2°� 3D00 "°� MAXIMUM RATINGS n R '" , ti ® Volta9elyl ReviEIWed BY. COMPOSITION SHINGLE Operational Temperature -40-+85°C Trina Solar is introducing Trinamount-the fastest,easiest and least Maximum System Voltage 1DDDVDC(IEC)/600V expensive way to mount PV modules onto residential and commercial DC(UL) _ ® rooftops.With a series of drop-in and quarter-turn connections on a Max Series Fuse Rating 15A TRAPEZOIDAL METAL specialized module frame,this mounting solution installs up to 5 times CERTIFICATION faster than conventional mounting systems.Trinamount connects directly to the module frame,eliminating the need for long rails. E PV"`YCLE cus WARRANTY ® STANDING SEAM ROOF By drastically reducing the number of parts,cost of materials and n 0year workmanship warranty installation time,Trinamount offers the optimal solution for residential Cp► 25 year linear performance warranty and commercial installations. (Please refer to product warranty for details) �OOMP4rye • Trinasolarq / W Trinasolar CAUTION READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. The power behind the panel CDMPNS,O The power behind the panel ®2011 Trina Solar Limited.All rights reserved.Specifications included in this datasheet are subject to change without notice. SolarCity SleekMountTM - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules ' Drill Pilot Hole of Proper Diameter for aesthetics while minimizing roof disruption and .Interlock and grounding devices in system UL labor.The elimination of visible rail ends and listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2 mounting clamps, combined with the addition 0 Seal pilot hole with roofing sealant of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 to a more visually appealing system.SleekMount as"Grounding and Bonding System" 0 Insert Comp Mount flashing under upper layer TM � la of shingle utilizes Zep Compatible modules with •Ground Zep UL and ETL listed to UL 467 as y g strengthened frames that attach directly to grounding device 0 Place Comp Mount centered Zep Solar standoffs,effectively eliminating the need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition .Anodized components for corrosion resistance Install lag pursuant to NDS Section 11.1.3 shingles are not required to be cut for this with sealing washer. system,allowing for minimal roof disturbance. •Applicable for vent spanning functions "� Secure Leveling Foot to the Comp Mount using machine Screw ® Place module + Components ® • 5/16"Machine Screw ® Leveling Foot O Lag Screw Comp Mount ® _ 0 Comp Mount Flashing 0 y ® CUPERTINO Building Department 5 2013 DE 6WQAt,, _ F U REVIEWED FOR CO COMP�LEAN Solaitity. January 2013 �pco� �1� • LISTED sola�'ty® January 2013 Reviewed By* aowe-oae® `JRenewoble Energy SOIUIionS AURORA 1 • ' • ' • ' Nominal Output Power W 3000 3600 4200 maximum Output Power W 3000 3300** 1 3300** 3600 4000** I 4000** i 4200 4600** 1 4600** w Rated Grid AC Vok_age _ V j _208 240 277 I .,208 240 277 208 240 277 Number of Independent MPPT Channels 2 2 2 ^`V�'.a a®�� Maximum Usable Power for Each Channel W 2000 3000 3000 Absolute Maximum Voltage(Vmax) V 600 600 600 Start-Up Voltage(Vstart) V 200(adj.120-350) 200(adj.120-350) 200(adj.120.350) P`/ y o/!�� Full Power MPPT Voltage Range V i� 160-530 120-530 140-530 V 3 ® Operating MPPT Voltage Range i V 0.7xV_start-580 0.7xVstart-580 j 0.7xVstart-580 Maximum Current(ldcmax)for both MPPTin Parallel' A 20 32 32 �/ /'^ _� Maximum Usable Current per Channel A 10 16 16 a Maximum Short Circuit Current Limit per Channel A 12.5 20 1 20 Number of WireLan_dingTerminalsPerChannel 2 Pairs(1on-S version) I 2 Pairs(1on-S version) 1 2 Pairs(1on-S version) GENERAL SPECIFICATIONS .� ouipyt sld�(ACi - Array Wiring Termination Terminal block,Pressure Clamp AWG10 nwG4 �Y saaiLlr Split- Split- Split- OUTD00R MODELS Grid Connection Type 10/2W 0/3W 10/2W 1012W 0/3W 10/2W 1012W 0/3W 10/2W Adjustable Voltage Range(Vmin-Vmax) V_ 183.228 211-264 1 244304 183-228 211-264 1 244304 i 183-228 2.11-264 244304 Grid Frequency _ Hz 60 60 I 60 Adjustable Grid Frequency Range Hz 57-60,5 I 57-60.5 57-60.5 Maximum Current(lacmax) Aes's 14.5 14.5 !, 12 _ 17.2 1 16 1 16 1 20 k 20 C u P L9'7"�P�I V D _ Power Factor >0.995 I >0.995 i i\ I ' O f I .I 8ui�dina t�ra Grid Wiring Termination % <2 Terminal 2 C$ ent ,9 YP - - -- - amp AW [ ��U17 0 nal block,Pressure CI G10-AWG4 Input , < - - 5 201 — - - - Reverse Polarity Protection Yes Yes Over4oltageProtectionType Varistor,2 for each channel j Varistor,2 for each channel I Varistor,2_for each channel PV Array groundFau"etection Prestart-upRisoanddynamicGFDI(Re uiresFioatin Output -- -- - - - - - - - - --- -q ,—g/��'�/fEVd�:i�- CODE COMPLIANCE FOR Anti-IslandingProtection Meets UL1741/IEE1547 � MeetsUL1741/IEE1547 Meets UL1741/IEE1547 requirements - requirements requir�¢ ;� �� �Y' � over-Voltage Protection Type Varistor,2(L,-L:/Li-G) Varis_tor,2(L,-L2/L,-G) Varistor,2(L,- z , H Maximum AC OCPD Rating A 20 L 20 15 25 209 20 R 25 25 25_ Maximum E(ficienry__ _ % r 96.9 V- 97- 97 CEC Efficiencgr % 96 96 96 Stand-byConsumption Wang <8 <8 _ -- I <8 Nighttimeconsum tion Wa <06 <0.6 m <0.6 User4nterface 16 characters x 2 lines LCD display Remote Monitoring(I%RS48S inci.) AURORA-UNIVERSAL(opt.) Wired Local Monkodng(1XRS48S incl.) - PVI-USB-RS485_232(opt.),PVI DESKTOP(opt) Wireless Local Monitoring PVI-DESKTOP(o tJ with PVI-RADIOMODULE AmbfentAir OperetingTempereture Range °F(°C) 13 der to+140(-25 to+60)with 13 to+140(-25 to+60)with 13 to+140(-25 to+60)with _ - ating above 131(55) deratigg above 131[SS) deratinig abov-e 113(45) _ - Ambi entAirStorageTemperatu_reRange__ - -*F(°C) -40 to 176(-40 to+80) -40 to 176(-40 to+80) _ -40 to 176(-40 to+80) ReWthreHumidity %RH 0-100 condensing 0-100 condensing_ 0-100 condensing . -- - -- -- -- - ------- -- - ----- - AcousticNoiseEmissionLevel db(A)@im-_.-_ -_.-__<50___ <50 <50 Maximum O orating Akkude without Deratin ft(m) 6560(2000) 6560(2000) 6560(2000) EndosureratiRg NEMA4X NEMA4X__ _ NEMA4X ______ ------ ----- -- - - - — ----- + Coolin Natu_ra_I_Con_vection Natural Con- ion Natural Convection 9 Dimensions(HxWx_D) 'i in(mm) I 33.8x12.8x 8.7(859 x 325 x 222)-S Version Weight lb/(kg) <47.3(21.3)-S version [ <47.3(21.3)-S version j <47.3(21.3)-S version Mounting System Wall bracket Wall bracket Wall bracket t' Trade size KOs:(tea x 1/2')and Trade size KOs:(tea x 1/2")and i Trade size KOs:(tea x 1/2")and Y " -� -•"� '�� - - ,�i Conduit Connections*"* (2eax1-1/4,3 laces side,front, (2eax1-1/4,3 laces side,front, (2eax1-1/4,3 laces side,front, - - P P x P rear) rear) rear) m y DC Switch Ratingr[Per Contact) AN 25/600 25/600 r Qt• G - - r ��:. Safe' '.. ___ _.. a �A Isolatlon Level Transformerless(Floating Array) Transformerless(Floating Array) Transformerless(Floating Array)xt ,- '--_�` , Safety and EMC Standard UL 1741,CSA-C22.2N.107.1-01 UL 1741,CSA-C22.2N.107.1-01 UL 1741,CSA-C22.2 N.107.1-01 *Z v � •} < CSA., t•.=;"� a��- � t=�ti to .a t�:Y�U"f� ,- ff�d�1 2�-� ';LC' �'^r, Safet ra , --- - - -_ --------- ----- _ -y A-pp CSA,,, oyl CSA..-- - ...y .'x , Ei.w � Warran ,} od osu �sLIt1C sI� r;,sP i of ~„ - !Y - - - - - - - - - _z} =,$r :?,`.& ?` Standard Warranty ears 10 10 10 e::t''• -' .,,f".�•x`•.-:�:. sxr,� tY Y 'and r„ ct. " ?I a �seo nece3, c�;itlo "]i itFij"'rnatioi),: s(:,�a'�/rs.ol .. ,<, , ,..v:.r ears lsazo lsazo 15&20 u,• Px a, tt z s .° sz..B,r.. `iv Extended Warranty years •.n`�1�,x?i?�`2.':<..-;€ .,�,�e..,u,s z; <,„=,."C '. ,..t-.:,..,^, fy . + # '�:.v� r r�` ,.,. :?• S8fi.� mrfnl���on Ilfeiace'(for`-ion ectiz, 3c' to dl dt Qye �., ,, ;s x5 - - - - �s iy; Available Models x:= 1 S• O t11G�t1 `V1l ilr. rbPa•, f3i S ' z=J x"r r - .7= `_'`:'" Standard-Without DC Switch and Wiring Box PVL3.0 OUTD-US PVI-3.6-OUTD-U5 PVI-4.2-OUTD-US r�..,>.�.;-, Cg'mptibiiw�thYP�t:V_Nomdo I br Wit,s c-tnu:.....•„ .P� �_ �. :_ „. o s PVI-3.6OUTD-5-US PVI 4.2-OUTD-S-US With DC Switch and Wiring Box PVI 3.0 UTD S U -All data i subject to change without notice ••Capability enabled at nominal AC witage and with sufficient DC power available •e• ® "••When equipped with optional DC Switch and Wiring Box •'•®• CSA INTERNATIONAL Certificate of Compliance Certificate: 2096477 Master Contract: 173688 Project: 2439385 Date Issued: July 19,2011 Issued to: Power-One,Inc 740 Calle Plano Camarillo,CA 93012 USA Attention:Robert White The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C'and 'US'for Canada and US or with adjacent indicator 'US'for US only or without either indicator for Canada only. ® Rob-If e v Tstork Issued by: Rob Hempstock,AScT. C US PRODUCTS CLASS 531109 -POWER SUPPLIES-Distributed Generation Power Systems Equipment CLASS 531189 -POWER SUPPLIES-Distributed Generation-Power Systems Equipment -Certified to U.S.Standards Utility Interactive Inverter,Models PVI4.2-OUTD-US,PVI-3.6-OUTD-US,PVI-3.0-OUTD-US,PVI4.2- OUTD-S-US,PVI-3.6-OUTD-S-US,PVI-3.0-OUTD-S-US,PVI4.2-OUTD-US-W,PVI-3.6-OUTD-US-W and PVI-3.0-OUTD-US-W;provided with two DC input channels,permanently connected. For details related to ratings,reference should be made to the CSA Certification Record,Appendix 1 or the Descriptive Report. APPLICABLE REOUIREMENTS CUPERTINO CSA-C22.2 No.107.1-01 - General Use Power Supplies ��idnq oepar rent UL Std No. 1741-Second Edition - Inverters,Converters,Controllers and Interconnection System Equipment ? for Use With Distributed Energy Resources(January 28,2010) =i AUG PL04CE REVLE��� FOR CODE CoM►�, . ,��viewed gy: DQD 507 Rev.2009-09-01 Page:I