Loading...
13030055I CITY OF CUPERTINO BUILDING PERMIT . BUILDING ADDRESS: 10314 MICA VISTA RD OWNER'S NAME: SUMNER ROBERT B AND BETTY M OWNER'S PHONE: 4084820227 ❑ LICENSED CONTRACTOR'S DECLARATION License Class azAj Lic. # ` . Contractor - to I hereby affirm that I am licensed under the provisions.of C (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect - I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self - insure for Worker's Compensation, as provided for by Section 3700 of the labor Code, for the performance of the work for which this permit is issued. 1 have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. - APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section s 9.18. I Signature Date - -� ❑ OWNER - BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business &Professions Code) 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. CONTRACTOR: SOLARCITY PERMIT NO: 13030055 3055 CLEARVIEW WAY DATE ISSUED: 03 /122013 SAN MATEO, CA 94402 PHONE NO: (650) 638 -1028 JOB DESCRIPTION: RESIDENTIAL u COMMERCIALW INSTALL 22 ROOF TOP FLUSH MOUNTED SOLAR PANELS (5.39KW). UPGRADE (E) ELECTRICAL PANEL TO 150 AMPS, SAME LOCATION. Sq. Ft Floor Area: I Valuation: $25000 APN Number: 35702022.00 1 Occupancy Type: PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Date: RE- ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Sections 25505, 25533, and 25534. _ Owner or authorized CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed CUPERTINO ALTERNATIVE ENERGY PERMIT APPLICATION^ oO COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION rr�� 10300 TORRE AVENUE • CUPERTINO, CA 95014 -3255 �` t AE (408) 777 -3228 • FAX (408) 777 -3333 • buildinD(cDcupertino.oro U PROJECT ADDRESS I "No OWNER NAME P �' SZ-oZZ O q STREETADDRESS / //) �Q / CFFY A ZJF.... / /(' —iT/ 6•JE FAX CONTACT NAME S k)/ 54) 44 `Q PHO -4A� E. STREET ADDRESS CITY. STATE. ZIP FAX ❑ OWNER ❑ OWNER- BUILDER ❑ OWNER AGENT CONTRACTOR ❑ CONTRACTOR AGENT ❑ ARCHITECT Cl ENGNEER ❑ DEVELOPER ❑ TENANT CONTRAGTORNAME 1 �a LICENSE NUMBER a LICENSEI TYPED` I `I HUS.LI �rF ( COANY NAME MP —J�I� 1029 STREET ADD S /l/Y i I� r CT' TE. l_ ` 7 i ARCHITECTIENGINEER NAME LICENSE NUMBER BUS. LIC 0 COMPANY NAME E -MAD. FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF SFD or Duplex ❑ Multi- Family USE OF RE: ❑ Commercial PROJECT M WILDLAND URBAN INTERFACE AREA ❑ Yes ❑ NO PROJECT M FLOOD ZONE ❑ Yes ❑ No SOLAR PANELS 1 ❑ ELECTRICVEFRCLECHAROMGSTATION ❑ SOLARWATERHEATNG ❑ OTHER: FOR SOLAR PANELS: NUMBEROFPANELSMBTS: KBAWAT""B' �.,57�A TOTAL VALUATIO DESCRIPTION OF WORK nj By my signature below, I certify to each of the followin application and the information I h e pr 'ded is torte ordinances and state taws relatin bu' g constructs Signature of ApplicandAge : 1 am t e property owner or authorized agent to act on the property owner's half. I hav Is . I hav read the Descn on of Work and verify It is accurate. I agree to comply with all applicable local I au orize represent s of Cupertino to enter the above - identified property for inspection purposes. Date: SUPPLENENTAVITORMATION REQUIRED Ch�) pET:TTCE USE ONLY csi' ".. .- Z - 3 -' , .- YBR 171M .COUNTER O„EJCPRESS^ - �❑. STANDARD ❑ LARGE ❑ MAJOR 4— _ , FVApp_2011.doc revised 03116111 &VI'% CITY OF CUPERTINO LaVV 7'iCTIMAT(1R— RIT11.11INC' 111VI.C'ION iblech. Plan Check tLleclr. Permit Fe<�• Other 'lath. Insp L 1 -Inch, Insp. Fee: _ NOTE: This estimate does not Plumb. Plan Check Plumh. Pe"Mir Fee: Ocher Plumb Insp. L Plumb. 6rs'p. Fee: e to other Departments Elec. Plan Check 0.0 Ins $0.00 Elec. Permit Fee: IEPERA11T Other Elec. Insp. 0.0 hrs $45.00 Elec Insp. Tee: Public Works, Fire, Sanitary Sewer District, School FEE ITEMS (Fee Resolution 11 -053 E . 712) ADDRESS: 10314 MIRA VISTA RD DATE: 03/1212013 REVIEWED BY: MELISSA MISC ITEMS APN: 357 02 022 BP #: VALUATION: $25,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Du lex p 0.0 PENTAMATION SOLAR -RES PERMIT TYPE: USE: PME Plan Check: WORK INSTALL 22 ROOF TOP FLUSH MOUNTED SOLAR PANELS 5.39kW . UPGRADE E ELECTRICAL SCOPE I PANEL, SAME LOCATION. iblech. Plan Check tLleclr. Permit Fe<�• Other 'lath. Insp L 1 -Inch, Insp. Fee: _ NOTE: This estimate does not Plumb. Plan Check Plumh. Pe"Mir Fee: Ocher Plumb Insp. L Plumb. 6rs'p. Fee: e to other Departments Elec. Plan Check 0.0 Ins $0.00 Elec. Permit Fee: IEPERA11T Other Elec. Insp. 0.0 hrs $45.00 Elec Insp. Tee: Public Works, Fire, Sanitary Sewer District, School FEE ITEMS (Fee Resolution 11 -053 E . 712) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 1 # Alternative Energy System $219.00 IPNOTOVRES Photovoltaic System Suppl. PC Fee: Q Reg. Q OT 0.0 hrs $0.00 PME Plan Check: $0.00 150 amps Electrical $45.00 IBELEC200 Services Permit Fee: $0.00 Suppl. Insp. Fee.S Reg. O OT 0,0 1 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $45.00 Construction Tax: Administrative Fee: IADMIN $42.00 O E) Work Without Permit? O Yes Q No $0.00 Advanced Planning; Fee: $0.00 Select a Non - Residential Building or Structure E) C!, Travel Documentation Fee: ITRAVDOC $45.00 Strong Motion Fee: IBSEISMICR $2.50 1 Select an Administrative Item Blde Stds Commission Fee: IBCBSC $1.001 $135.50 $264.00 , TOTAL FEE: $399.50 \cv Revised: 01/01/2013 Building Department City Of Cupertino 10300 Torre Avenue Cupertino, CA 95014 -3255 Telephone: 408- 777 -3228 C U P E RT I N O Fax: 408- 777 -3333 CONTRACTOR / SUBCONTRACTOR LIST ^ ` *Our municipal code requires all btAinesses working in the city to have a City of Cupertino business'license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPEC ON(S) WILL BE, SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONT CTO HAVE O AINED A CITY OF CUPERTINO BUSINESS LICENSE. < I am not using any subcontractors: ature Date Please check applicable subcontractors and complete the following information: ✓ SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring / Carpeting Linoleum / Wood Glass / Glazing Heating Insulation Landscaping Lathing Masonry Painting / Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile t / Contractor Signature :1 3 . Date ABBREVIATIONS ELECTRICAL NOTES INDEX LICENSE JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING PV1 COVER SHEET CA # 888104 Installing 22 -roof top flush- mounted panels ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN PV2 PV3 SITE PLAN STRUCTURAL VIEWS C -46, C -10 5.39 kW); upgrading electrical service panel with BL BLDG BUILDING POSITION, A SIGN WILL BE PROVIDED WARNING 100A main breaker and 125A main CONC CONCRETE OF THE HAZARDS PER ART. 690.17. PV4 STRUCTURAL VIEWS panel. C COMBINER BOX 2, EACH UNGROUNDED CONDUCTOR OF THE PV5 UPLIFT CALCULATIONS D DISTRIBUTION PANEL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PV6 THREE LINE DIAGRAM DC DIRECT CURRENT BY PHASE AND SYSTEM PER ART. 210.5. PV7 ELECTRICAL CALCULATIONS Flashing will be painted to match exterior EGC EQUIPMENT GROUNDING CONDUCTOR 3. A NATIONALLY - RECOGNIZED TESTING Cutsheets Attached (E) EXISTING LABORATORY SHALL LIST ALL EQUIPMENT IN EMT ELECTRICAL METALLIC TUBING COMPLIANCE WITH ART. 110.3. G SOLAR GUARD METER 4. CIRCUITS OVER 250V TO GROUND SHALL GALV GALVANIZED COMPLY WITH ART. 250.97, 250.92(B) CUTSHEETS ATTACHED GEC GROUNDING ELECTRODE CONDUCTOR 5. DC CONDUCTORS EITHER DO NOT ENTER GND GROUND BUILDING OR ARE RUN IN METALLIC RACEWAYS GENERAL NOTES HDG HOT DIPPED GALVANIZED OR ENCLOSURES TO THE FIRST ACCESSIBLE DC I CURRENT DISCONNECTING MEANS PER ART. 690.31(E). PLOT PLA 4S Imp CURRENT AT MAX POWER 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN 1. THIS SYSTEM IS GRID - INTERTIED VIA A CUECKED DY INVS INVERTERS RELIEF AT ALL ENTRY INTO BOXES AS UL- LISTED POWER - CONDITIONING INVERTER. Isc SHORT CIRCUIT CURRENT REQUIRED BY UL LISTING. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. kVA KILOVOLT AMPERE 7. MODULE FRAMES SHALL BE GROUNDED AT THE 3. PHOTOVOLTAIC SOURCE AND INPUT CIRCUITS AND LATE kW KILOWATT UL- LISTED LOCATION PROVIDED BY THE INVERTER INPUT CIRCUIT ARE UNGROUNDED. I LBW MIN LOAD BEARING WALL MINIMUM MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 4. 5. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED ALL WORK TO BE DONE TO 2010 CALIFORNIA U` F"ICE CUP��f LN MIR MIRROR 8. ALL EXPOSED METAL PARTS (MODULE FRAMES, BUILDING CODE. DATE (N) NEW RAIL, BOXES, ETC.) SHALL BE GROUNDED USING 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE NEC NATIONAL ELECTRIC CODE UL LISTED LAY -IN LUGS LISTED FOR THE 2008 NATIONAL ELECTRIC CODE AS AMENDED BY NIC NOT IN CONTRACT PURPOSE. POSTS SHALL BE MADE THE 2010 CALIFORNIA ELECTRIC CODE. �� 1riaEPT. NTS NOT TO SCALE ELECTRICALLY CONTINUOUS WITH ATTACHED OC ON CENTER RAIL. P PANEL BOARD 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE PL PROPERTY LINES BONDED WITH EQUIPMENT GROUND CONDUCTORS PV PHOTOVOLTAIC AND GROUNDED AT THE MAIN ELECTRIC PANEL. PVC POLYVINYL CHLORIDE 10. THE DC GROUNDING ELECTRODE CONDUCTOR VICINITY MAP S SUBPANEL SHALL BE SIZED ACCORDING TO ART. SCH SCHEDULE 250.166(B) & 690.47. SS SSD STAINLESS STEEL SEE STRUCTURAL DRAWINGS CUPERTINO STC STANDARD TESTING CONDITIONS OMMUNITY DEVELOPMENT DEPARTMENT 'fir - �, Building Department SWH SOLAR WATER HEATER BUILDING DIVISION - CUPERTINO TYP UON TYPICAL UNLESS OTHERWISE NOTED _, APPROVED MAR 2 1 2013 UPS UNINTERRUPTIBLE POWER SUPPLY This set f plans and specifications MUST be kept at the r �" ` REVIEWED FOR CODE COMPLIANCE V Vmp VOLT job site VOLTAGE AT MAX POWER during construction. It is unlawful to make any A �� changes or alterations on same, or to deviate ' .- - 1' Reviewed By: Voc VOLTAGE AT OPEN CIRCUIT therefr m, without approval from the Building Official. I pI W WATT f,,; APN:357 -02 -022 3R NEMA 3R, RAINTIGHT The stamping of this plan and specifications SHALL NOT be held to permit o approval of the violation + " slons rdinance or State Law. "' ' ' REV BY DATE COMMENTS OFFICE COrd DATE PERMIT 0. 1 00 S �I CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT USED FOR THE JOB NUMBER J B- 9 5 014 0 4 0 0 PREMISE OWNER: SUMNER, AHJ DESCRIPTION: ROBERT SUMNER RESIDENCE DESIGN: ACHIA MARKET: RESI MODULES: TRINA SOLAR TSM- 245PC05 PA05.18 CE BENEFIT OF ANYONE EXCEPT SOLARCnY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 10314 MIRA VISTA RD 5.39 KW PV Array ,, �O���I� o PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH CUPERTINO, CA 95014 PROJECT MANAGER: MOUNTING SYSTEM: 3055 Clearview way San Mateo, CA 94402 T:(650) 638 -1028 F:(650) 638 -1029 THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. Comp Mount Type C PAGE NAME 408 482 -0227 SHEET: REV: DATE 3 7 1 / /2013 PAYMENT TYPE: INVERTER PPA POWER -ONE #AURORA PVI- 5000 -OUTD- S COVER SHEET PV 1 ( 886 ) -SOL -CITY (765- 2489) www.solarcity.com 10314 Mira Vista Rd TOTAL ARRAY AREA:396 TOTAL ROOF AREA: 144; TOTAL ARRAY AREA IS OF TOTAL ROOF AREA. Front Of H CONFIDENTIAL - THE INFORMATION HEREIN ,IDB NUMBEk J B- 9501404 00 CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI TRINA SOLAR I TSM- 245PC05 PA05.18 PART TO OTHERS OUTSIDE THE RECIPIENTS MANAGER: MOUNTING SYSTEM: ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE Comp Mount Type C SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: INVERTER PERMISSION OF SOLARCITY INC. PPA POWER -ONE # AURORA PVI- 5000 -OUTD- SUMNER, ROBERT 10314 MIRA VISTA RD CUPERTINO, CA 95014 (408) 482 -0227 Fence ted to match ` 'r Building Depat MIA" " 2 S 2013 F rV!'FVVED PvIR rnnF rnmpi In FZ'evievvad B � ,.r , PITCH: 21 ARRAY PITCH: 21 MP1 AZIMUTH: 270 ARRAY AZIMUTH: 270 MATERIAL: Comp Shingle STORY: 1 S1 PITCH: 21 ARRAY PITCH: 21 MP2 AZIMUTH: 90 ARRAY AZIMUTH: 90 MATERIAL: Comp Shingle STORY, 1 S1 LEGEND O (E) UTILITY METER & WARNING LABEL Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS AC AC DISCONNECT & WARNING LABELS F(2-51 JUNCTION BOX Q DC COMBINER BOX & WARNING Q DISTRIBUTION PANEL & WARNING R LC LOAD CENTER & WARNING LABELS i DEDICATED PV SYSTEM METER CONDUIT RUN ON EXTERIOR CONDUIT RUN ON INTERIOR GATE /FENCE _ - - INTERIOR EQUIPMENT SITE PLAN Scale: 3/32" = V 01' 10' 21' N W E S SUMNER RESIDENCE ACHIA °- 1"�F. S olarCit 5.39 KW PV Array A �.�/ PAGE NAME: SHEET: REV: DATE: SITE PLAN I PV 2 3/7/2013 3055 Clearview Way San Mateo, CA 94402 T:(650) 638 -1028 R(650) 638 -1029 (888) -SOL -CITY (765 -2489) www.solarcity.com PV MODULE " BOLT WITH LOCK & FENDER WASHERS ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP COMP MOUNT C ZEP FLASHING C (E) COMP. SHINGLE (E) ROOF DECKING N" LAG BOLT WITH SEALING WASHER (E) RAFTER RAFTER: 2x4 SUPPORT: 2x4, 1x6 MAX SPAN: 8' -7" A SIDE VIEW OF MP1 SUBSEQUENT MODULES S CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: J B- 9501404 00 CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI TRINA SOLAR I TSM- PART TO OTHERS OUTSIDE THE RECIPIENT'S (E) 2x4 RAFTER 0 24" O.C. (E) 1x6 RIDGE BOARD (BLOCKING) (E) 2x4 (E) 20 CEILING JOIST 0 16" O.C. ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER MOUNTING SYSTEM: THE SAL: AND USE OF THE RESPECTIVE Comp Mount Type C SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: NVERTER: PERMISSION OF SOLARCITY INC. PPA I POWER —ONE # AURORA PVI- 5000 —OU PREMISE OWNER AH,k SUMNER, ROBERT 10314 MIRA VISTA RD CUPERTINO, CA 95014 (408) 482 -0227 4' -0" DESCRIPTION: SUMNER RESIDENCE 5.39 KW PV Array PAGE NAME STRUCTURAL VIEWS (E) 2x4 RAFTERS 0 24" SPACING FRONT VIEW OF MP1 R EVi C-_!A'F SCALE: 1/2" = V CUPERTINO Building Department WXr%' 2 1 2013 D FOR CODE COMPLIANCE Peviewod By: � .� }7�1101/ ACHIA olarcit 3055 ClearOew Way SHEET: REV: DATE: San Mateo, CA 94402 T:(650) 638 -1028 F:(650) 638 -1029 P V 3 3/7/2013 (888) -SOL -CITY (765 -2489) www.solardty.com INSTALLATION ORDER (1) LOCATE RAFTER, MARK HOLE . LOCATION, AND DRILL PILOT HOLE. (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. (3) INSERT FLASHING. (4) PLACE MOUNT. C5)1 INSTALL LAG BOLT WITH SEALING .WASHER. G(6)' NSTALL LEVELING FOOT WITH BOLT & WASHERS. ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER MOUNTING SYSTEM: THE SAL: AND USE OF THE RESPECTIVE Comp Mount Type C SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: NVERTER: PERMISSION OF SOLARCITY INC. PPA I POWER —ONE # AURORA PVI- 5000 —OU PREMISE OWNER AH,k SUMNER, ROBERT 10314 MIRA VISTA RD CUPERTINO, CA 95014 (408) 482 -0227 4' -0" DESCRIPTION: SUMNER RESIDENCE 5.39 KW PV Array PAGE NAME STRUCTURAL VIEWS (E) 2x4 RAFTERS 0 24" SPACING FRONT VIEW OF MP1 R EVi C-_!A'F SCALE: 1/2" = V CUPERTINO Building Department WXr%' 2 1 2013 D FOR CODE COMPLIANCE Peviewod By: � .� }7�1101/ ACHIA olarcit 3055 ClearOew Way SHEET: REV: DATE: San Mateo, CA 94402 T:(650) 638 -1028 F:(650) 638 -1029 P V 3 3/7/2013 (888) -SOL -CITY (765 -2489) www.solardty.com PV MODULE " BOLT WITH LOCK & FENDER WASHERS ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP COMP MOUNT C ZEP FLASHING C (E) COMP. SHINGLE (E) ROOF DECKING A" LAG BOLT WITH SEALING WASHER (E) RAFTER RAFTER: 20 SUPPORT: 2x4, 1x6, 1x8 MAX SPAN: 9' -1" C SIDE VIEW OF MP2 S2 STANDOFF (E) 20 RAFTER @ 24" O.C. (E) 1x6 RIDGE BOARD (E) 1x8 (E) 2x4 (E) 2x4 CEILING JOIST ® 16" O.C. 4' -0" (E) 2x4 RAFTERS ® 24" SPACING FRONT VIEW OF MP2 SCALE: 1/2" = 1' CUPERTINO A 801ding Department I WlA 2 It 2'013 Rc\`IEVVED FOR CODE COMPLIANCE Reviewed By: CONFlDENIIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT E USED RCI THE BENEFlT OF ANYONE EXCEPT SOLARgTY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART ORGANIZATION, OTHERS OUTSIDE THE RECIPIENT'S THE SALE AN EXCEPT IN CONNECTION WITH THE SALE AND USE T, THE RESPECTIVE SOLARCTY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. INSTALLATION ORDER PREMISE OWNER: AHd DESCRIPTION: SUMNER, ROBERT SUMNER RESIDENCE 10314 MIRA VISTA RD 5.39 KW PV Array CUPERTINO, CA 95014 PAGE NAME S 408 482 -0227 STRUCTURAL VIEWS DESIGN: ACHIA (1) LOCATE RAFTER, MARK HOLE LOCATION, AND DRILL PILOT HOLE. MODULES: TRINA SOLAR TSM- 245PC05 PA05.18 . (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. MOUNTING SYSTEM: COn1 Mount T e C 3055 CleaMewWay San 5 Cle a CA 94402 T:(650) 638 -1028 F:(650) 638 -1029 (888) -SOL -CITY (765- 2489)www.solardry.00m (3) INSERT FLASHING. NWRTER: POWER -ONE #AURORA PV1- 5000 -OUTD- (4) PLACE MOUNT. (5) INSTALL LAG BOLT WITH SEALING WASHER. G(6) INSTALL LEVELING FOOT WITH BOLT & WASHERS. 4' -0" (E) 2x4 RAFTERS ® 24" SPACING FRONT VIEW OF MP2 SCALE: 1/2" = 1' CUPERTINO A 801ding Department I WlA 2 It 2'013 Rc\`IEVVED FOR CODE COMPLIANCE Reviewed By: CONFlDENIIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT E USED RCI THE BENEFlT OF ANYONE EXCEPT SOLARgTY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART ORGANIZATION, OTHERS OUTSIDE THE RECIPIENT'S THE SALE AN EXCEPT IN CONNECTION WITH THE SALE AND USE T, THE RESPECTIVE SOLARCTY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: J B- 9501404 00 PREMISE OWNER: AHd DESCRIPTION: SUMNER, ROBERT SUMNER RESIDENCE 10314 MIRA VISTA RD 5.39 KW PV Array CUPERTINO, CA 95014 PAGE NAME S 408 482 -0227 STRUCTURAL VIEWS DESIGN: ACHIA �," %' � z "' SolarCity. MARKET: RESI MODULES: TRINA SOLAR TSM- 245PC05 PA05.18 . PROIECT MANAGER: MOUNTING SYSTEM: COn1 Mount T e C 3055 CleaMewWay San 5 Cle a CA 94402 T:(650) 638 -1028 F:(650) 638 -1029 (888) -SOL -CITY (765- 2489)www.solardry.00m °A� PV 4 3/7/2013 PAYMENT TYPE: PPA NWRTER: POWER -ONE #AURORA PV1- 5000 -OUTD- SoiarCity SleekMountTM 3/7/2013 Version # 4.1 Project Information System & MP Information Symbol Value Ground Snow Load Related Info Occupancy Category II Section 6.5.6.3 PV System Type V SolarCity SleekMount"' Comp Allowable Attachment Spacing Fig. 6 -1/ Local Data FV Module LHD Yingll YL245P -29b Total Number of Modules Edge 2= Fig. 6- 11B /C /D -14A/B Roofing Material h Comp Roof 48" 24" Section 6.2 (dumber of Layers (Comp Roofs Only; 2 dge I Edge-j- Corner Tile Reveal (Tile Roofs Only) Max Standoff Tributary Area NA p(up) -10.0 Roof Slope -27.0 21- Revile 'ed By Wind Pressure Down fosfl Spanning Vents? 10.0 No 10.0 3 psf PV Module Orientation Landscape and Portrait DLPV FV Module Length 39lbs 3.2 ft 39lbs PV Module V.,idth 5.4 ft b %LUP - 0.6 DLPV TCL Attachment Type -202 Ibs Comp Mount Type C Total Square Feet of Array 404 st Tallow 637 Ibs Wind Design Criteria Wind Design Code Coefficients ASCE 7 -05 Partially. Fully Enclosed Method Ground Snow Load I pg Exposure Category B Section 6.5.6.3 Basic Wind Speed V 85 mph Comp Allowable Attachment Spacing Fig. 6 -1/ Local Data Least Horizontal Dimension of Buildinq LHD Roof Style Edge Gable Roof Fig. 6- 11B /C /D -14A/B Mean Roof Height h Landscape Landscape 48" 24" Section 6.2 Wind zone Interior dge I Edge-j- Corner Max Standoff Tributary Area Wind Pressure Up (psfj p(up) -10.0 -17.4 -27.0 Revile 'ed By Wind Pressure Down fosfl Didov,,n; 10.0 10.0 10.0 3 psf Snow Design Criteria Coefficients Ground Snow Load I pg Table 7 -1 /1-ocal Data GUPER rINQ Building Department Comp Allowable Attachment Spacing (inches ) and Tributary Area (sf) Interior Edge Corner _ MARI 2 1 2013 Maximum Allevred Foot Spacing Maximum Allov ed Cantilever Landscape Landscape 48" 24" 46" 24" 48" 24" P_ �� "'�WEG FOR CODE COMPLIANCE Max Standoff Tributary Area TnbCL 13 sf 13 sf 13 sf Revile 'ed By PV Assembly Dead Load V-11 PV 3 psf 3 psf 3 psf DLPV PCL 39lbs 39lbs 39lbs b %LUP - 0.6 DLPV TCL -107 Ibs -202 Ibs -327 lbs Attachment Uplift Capacity Tallow 637 Ibs 637 Ibs 637 Ibs TC,iTalloc: DCRLand 16.7 °.b 31.70,b 51.4 CONFIDENTIAL –THE INFORMATION HEREIN CONTAINED SHALL NOT E USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC.. NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART IZ OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER- J[3-9501404 0 o PREMISE OWNER AHJ: DESCRIPTION: SUMNER, ROBERT SUMNER RESIDENCE 10314 MIRA VISTA RD 5.39 KW PV Array C U P E R TI N O , CA 95014 PAGE NAME: S (408) 482 -0227 UPLIFT CALCULATIONS DESIGN: ACHIA � �,1, �O���I� ` MARKET: RESI MODULES: TRINA SOLAR TSM- 245PC05 PA05.18 • PROJECT MANAGER: MOUNTING SYSTEM: Comp Mount T B C 3055 Clearview Way Sa55Clearview ay T:(650) 638-1028 C(650) 638 -1029 ( 888)- SOL- CnY(765 -2489) www.solarcity.com SHEET: REV: DATE PV 5 3/7/2013 PAYMENT TYPE: PPA INVERTER: POWER -ONE # AURORA PVI- 5000 -OUTD- #8 GEC TO (E) WATER PIPE AT N 12M MAIN SERVICE PANEL 04 WITH IRREVERSIBLE CRIMP �N; 100/2P MAIN CIRCUIT BREAKER Panel Number: SQUARE D Meter Number: 1006679287 Overhead Service Entrance MAIN SERVICE PANEL INV 1 — (1)IPOVER— A RORA I-5000— OUTO -US LABEL A INV 2 INV 3 (') ° I3DAO. 2 Spocas I 1 PV BACKFEED BREAKER AC O3 �(, > AWG #10, TRWN -2. Block L=L (1) AWG /10. 7HWN -2, Red I111���I111 (I )Awc p% 7m -2, wits NEUTRAL Vmp =240 VAC Imp= 20.83AAC (, ) AWG A TN,W 72, Green ..... EGC/w. ...- 0) CanopR KIk .3/4• D4T ............ Inverter 1 IND POWER —ONE 1RORA PVI- 5000 — OUTD —US — (22) TR91A SOLAR I TSM- 245PCO5/PA05.18 PV MoAds: 245W, 222.9W PTC, 40NM, Block Frans VOC: 37.3 Vpmax: 30.7 *MODULE CURRENT RATINGS ARE SHOWN AS Isc AND ImD IN -- — — — — — — — — — — — — — — — — — — I I I --1----------------------- (1 ) ConduR Kit 3/4• EMT C -46, C -10 DO NOT ADJUST MIN. ACTIVATION V TAGE I p� - - - - I String(s) Of 11 On MP 1 EG -- — — — — — — — DO NOT ADJUST MIN. ACTIVATION VQgLTATGEE I I pC - - - - 1 String(s) Of 11 On MP 2 q I I -- - - - - - - - ( Building Department PEAR 2 1 2013 REViEWEE—Dr FOR CODE COMPLIANCE Reviewed By: DC I O1 277_ EGC VOC Vmp GFP /GFCI Isc =8.47 Imp= 7.98 ADC ADC 2 O — (22) TR91A SOLAR I TSM- 245PCO5/PA05.18 PV MoAds: 245W, 222.9W PTC, 40NM, Block Frans VOC: 37.3 Vpmax: 30.7 *MODULE CURRENT RATINGS ARE SHOWN AS Isc AND ImD IN -- — — — — — — — — — — — — — — — — — — I I I --1----------------------- (1 ) ConduR Kit 3/4• EMT C -46, C -10 DO NOT ADJUST MIN. ACTIVATION V TAGE I p� - - - - I String(s) Of 11 On MP 1 EG -- — — — — — — — DO NOT ADJUST MIN. ACTIVATION VQgLTATGEE I I pC - - - - 1 String(s) Of 11 On MP 2 q I I -- - - - - - - - ( Building Department PEAR 2 1 2013 REViEWEE—Dr FOR CODE COMPLIANCE Reviewed By: DC I O1 (2) AWG /10, PV WIRE, Black (1) AWG it SdM Bare Copper EGC VOC Vmp =410.3 VDC = 337.7 VDC Isc =8.47 Imp= 7.98 ADC ADC 2 O ( 2) AWG p0. PV 9M Block (I) AWG ^ SoBd Bare Capper EGC VOc Vmp 410.3 VDC = 337.7 VDC Isc — 8.47 Imp= 7.98 ADC ADC CONFlDENIIAL —THE INFORMATION HEREIN JOB NUMBER J B- 9501404 OO PREMISE OWNER AHk DESCRIPTION: um: CONTAINED SHALL NOT USED FOR THE SUMNER, ROBERT SUMNER RESIDENCE MARIO =T; RESI MODULES: TRINA SOLAR TSM- 245PC05 PA05.18 E BENEFlT OF ANYONE EXCEPT SOIARgTY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 10314 MIRA VISTA RD 5.39 KW PV Array SolarCity. PART IZ OTHERS OUTSIDE ON RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH CUPERTINO, CA 95014 CTMANAGER: MOUNTING 3055 Clearview Way San Clearview ay THE SALE AND USE OF THE RESPECTIVE SOLARgTY EQUIPMENT, WITHOUT THE WRITTEN COnI Mount Type C PAGE NAME: SHEET: REV DATE: PAYMENT TYPE: PPA INVERTER POWER —ONE #AURORA PVT- 5000 —OUTD— PERMISSION OF SOLARCITY INC. 408 482 -0227 S THREE LINE DIAGRAM PV 6 3/7/2013 T:(650) 638 -1028 F:(650) 638 -1029 (888)- SOL- CrfY(765- 2489)www.so1arcity.com 1. Conductor Sizing per Art 690.8(6)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.15(B)(16). c. Evaluate conductor temperature at terminations per 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current *1.25. All string terminations are rated at 90' C. ------------------------------------------ 2. OCP Sizing per Art 690.8(8)(1) a. Round up to next size per Art 240.4(B) 3. Conductor Sizing per Art 690.8(B)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). Module: 22 Trina TSM- 245PC/PA05.08 Black Inverter 1: 1 Power -One PVI-6000 -S Module: Inverter 2: Module: Inverter 3: Module: Inverter 4: Total: 22 modules Photovoltaic Module Electrical Specifications Voc= 37.3 V Vmp= 30.7 V Ise= 8.47 A Imp= 7.98 A T%W= -0.11936 V /deg C Tisc= 3.981 mA/dea C ELECTRICAL CALCULATIONS 222.9 Inv Pwr W PTC Stri-en 96.50/6 5,000 4,732 11 Total Inv Pwr 5,000 4,732 PTC Total STC 5,390 deg F deg C Record Low Temp: 16 - 8.88888889 Max Average Hi Temp: 85 29.44444444 Power -One Strings: Parallel MPPT ine Drop Calculations Version _ (Imp) * (2 * Length) * (Resistance) / (Vmp) Imp (A) Max. Length (ft) Wire g: 7.98 35 1 C AWG 10 1 at Max Ave Hi: 85 deg F _ (7.98 A * 70 ft * 0.00124 Ohms) / 307 V = 0.23% ch: 15.96 60 C AWG 10 at Max Ave Hi: 85 deg F _ (15.96 A * 120 ft * 0.00124 Ohms) / 307 V = 0.77% Total voltage drop in DC conductors = 1.00% for: 20.83 20 1 C AWG 10 at 240V 3 = (20.83 A * 40 It *0.00120 Ohms) / 240 V 0.42% bined 20.83 0 C AWG 10 at 240V _ (20.83 A * 0 It * 0.00120 Ohms) / 240 V 0.00% Art 690.8(AX1) 1-way wire length: Total voltage drop in AC conductors = k:ont= 21.18 A Art 690.8(A)(1) Total voltage drop in AC and DC conductors = 1.42% 4. OCP Sizing a. Round up to next size per Art 240.4(B) b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.15(6)(16). String Type A and 2 Combined Strinas Type A Pwr -One PVh5000 -S 11 Tdna TSM- 245PC/PA05.08 Black Voc Correction Method: Manuf Tvoc data Inverter Min Vdc Input: 120 Vdc Branch Circuit Type A 1-way wire length: 60 it 2 strings per branch 1 11 modules per series string Voc= 410.3 V Min Vmp at Max Temp: 307 Vdc Voc= 410.3 V c. Evaluate conductor temperature at terminations per Art 110.14(C). Vmp= 337.7 V Max Voc at Min Temp: 455 Vdc Vmp= 337.7 V Ampacity of wire derated for conditions of termination must be >= continuous current *1.25. All branch terminations are rated at 75' C Ise= Imp= 8.47 A 7.98 A Inverter Max Vdc Input: Max String Size: 600 Vdc 14 Ise= Imp= 16.94 A 15.96 A min. ------------------------------------ - - - - -- k:ont= 10.59 A Art 690.8(AX1) 1-way wire length: 35 it k:ont= 21.18 A Art 690.8(A)(1) 1.a Conductor: C AWG 10 PV Wire 2.a Conductor 1: C AWG 10 PV Wire 4. OCP Sizing a. Round up to next size per Art 240.4(B) Icont * 1.25 = (Amps) 13.23 Icont * 1.25 = (Amps) Conductor 1: 26.47 ------------------------------------ - - - - -- 5. Conductor Sizing per Art 690.8(B)(1) 30 deg C ampacity, = 40 30 deg C ampacity = 401 1 1,b Icont= (Amps) 10.59 2.b Icont= (Amps) 21.18 a. Conductor must have 30 deg. C ampacity >= 125% of continuous Start ampacity 40 Start ampacity 40 current per Art 215.2(A)(1). Temperature derate (% =F) 0.76 Temp. derate ( % =F) 0.76 Conduit fill derate 1 Cndt. fill derate (%=#) 1 b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.15(B)(16). Derated ampacity 30.40 Derated ampacity 30.4 1.c Icont *1.25= (Amps) 13.23 Temp table Tenn 1 Term 2 75degC 75degC c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current *1.25. All inverter output terminations are rated at -75' C. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- Ampacity 1.d Icont ` 1.25 = (Amps) OCP size= 40 13.23 15 2.c (cunt *1.25= (Amps) Ampacity 2.d EGC OCP size = 26.47 26.47 3a 35 t-1%41 I-INTINO C AWG II Art. 250AMIlding Department 3b Inverter Type A Output Combined Inverter Output ;� I. '' ` � PEAR 1 1 213 6. OCP Sizing a. Round up to next size per Art 240.4(6) Power -One k:ont= PVI 6000 -S 20.83 A 1-uvay wire length: Art 690.8(A)(1) 20 it Total Service Voltage= Inverter Power 5,000 240 Volts Nameplate 0, EWE D FoRN*l We%%MPb.IMCE Icont = # of inverters *max inverter current Art 690.8(Ax1),,- hAl"VI 3.a Icont *1.25 = (Amps) 26.04 A Art 690.8(6)(1) 7. Conductor Sizing per Art 690.8(B)(1 a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). OCP size = 30 A Art. 240.6(A) Icont = (Amps) 20.83 Reviewed BY: 3.b Conductor C AWG 10 Icont * 1.25 = (Amps) 30 deg C ampacity = THWN -2 at 90 deg 26.04 40 C: Table 310.16 4.a Icont *1.25 = (Amps) OCP size = 26.04 A Art 690.8(B)(1) 30 A Art. 240.6(A) 4.b Conductor C AWG 10 THWN -2 at 90 deg C: Table 310.16 b. Conductor must have (after corrections for conditions of use) >= Icont * 1.25 = (Amps) 30 deg C ampacity = 26.04 40 3.c Icont= (Amps) 20.83 Start ampacity 40 continuous current per Table 310.15(B)(16). Temperature derate ( % =F) 0.91 4.c Icont= (Amps) 20.83 Conduit fill derate 1 Start ampacity 40 c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current *1.25. All inverter output terminations are rated at 75' C min. Derated ampacity 36.4 Temp. derate ( % =F) Cndt. fill derate ( %=#) Derated ampacity 0.91 1 36.4 3.d Icont *1.25= (Amps) 26.04 Ampacity 35 3.e EGC/GEC = D AWG 08 Art. 690.47(C)(3), 250.166(B) 4.d Icont *1.25= (Amps) Ampacity 26.04 35 CONFlDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE NOR BENERT SHALL LL ANYONE EXCEPT SOL MOLE INC., NOR SHALL IT BE DISCLOSED IN WHOLE aR IN PART IZ OTHERS OUTSIDE THE CONNECTION WITH ORGANIZATION, EXCEPT IN CONNECTION WITH. THE SALE AND USE OF THE RESPECTIVE SOLARgTY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. TDB NUMBER: J B- 9501404 00 P SUMNER, REMISE OWNER: Aft ROBERT 10314 MIRA VISTA RD CUPERTINO, CA 95014 S 408 482 -0227 DESCRIPTION: SUMNER RESIDENCE 5.39 KW PV Array PAGE NAME: ELECTRICAL CALCULATIONS DESIGN: ACHIA solalcity. MARKET: REST MODULES: TRINA SOLAR TSM- 245PC05 PA05.18 PROJECT MANAGER: MauNn►iG srsTEU: Comp Mount Type C 3055 aearview Way San 5 Cle°, CA 94402 ay T:(650) 638 -1028 F:(650) 638 -1029 ( 888)- SOL- C1TY(765- 2489)www.solarcity.com SHEET: REV DALE: PV 7 3/7/2013 [��ENT TYPE: PPA INVERTER �t POWER -ONE tt AURORA PVT- 5000 -OUTD- Building Department MAR 2 1 2013 REVIEWED FOR CODE COMPLIANCE Reviewed By ��s, r ���✓ CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT E USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. NEC 2008 220.82 - Residential Load Calculation Version 2.0 PREMISE OWNER: AHJ: DESCRIPTION: SUMNER, ROBERT SUMNER RESIDENCE 10314 MIRA VISTA RD 5.39 KW PV Array C U P E R TI N O, CA 95014 p PAGE NAME 40° 482 -0227 S ELECTRICAL LOAD CALCULATIONS DESIGN: ACHIA L1 /L2 240 V NEC 220.82(B) "The general calculated load shall be not less than 100% of the first 10 kVA plus 40% of the . remainder of the following loads..." PROJECT MANAGER: NEC 220.82(B)(1) "The calculated floor area shall not include open porches, garages, or unused ... spaces..." SHEET: REV. DATE: PV 8 3/7/2013 Floor Area 1,443 square feet x 3VA /sq ft 4,329 VA NEC 220.82(B)(2) °1500 volt- amperes for each 2 -wire, 20- ampere small appliance branch circuit and each laundry branch circuit..." Small Appliance Circuits 3 circuits x 1500VA /circuit 4,500 VA Laundry Circuits 1 circuits x 1500VA /circuit 1,500 VA Bathroom Circuits 1 circuits x 1500VA /circuit 1,500 VA NEC 220.82(B)(3) "The nameplate rating of all appliances... ranges, wall- mounted ovens, counter - mounted cooking & 220.82(B)(4) units... clothes dryers that are not connected to the laundry branch circuit... [and] water heaters" 2P Breaker VA Oven 30 5,760 Dryer 50 9,600; Spa 0; Pool 0; Pool 0; 0: 0' 0' 0' 01 0: 15,360 total VA Total of non air - conditioning loads: 27,189 total VA First 10 kVA of load at 100% 10,000 Remainder of load at 40% 6,876 Adjusted total of non air - conditioning load 16,876 VA NEC 220.82(C) "Heating and air - conditiong load..." 2P Breaker VA A/C Equipment Unit #1 30 5,760; A/C Equipment Unit #2 0 Total of A/C Loads and All Other Loads: 22,636 total VA Total Proposed Calculated Load: 94.32 Amps "64.i J B - 9561882 %; � I �o l arC ty © copyright SolarCity 2012 Building Department MAR 2 1 2013 REVIEWED FOR CODE COMPLIANCE Reviewed By ��s, r ���✓ CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT E USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER J B- 9501404 0o PREMISE OWNER: AHJ: DESCRIPTION: SUMNER, ROBERT SUMNER RESIDENCE 10314 MIRA VISTA RD 5.39 KW PV Array C U P E R TI N O, CA 95014 p PAGE NAME 40° 482 -0227 S ELECTRICAL LOAD CALCULATIONS DESIGN: ACHIA ���� �/, �ola�lty. MARKET: RESI MODULES: TRINA SOLAR TSM- 245PC05 PA05.18 . PROJECT MANAGER: MOUNTING SYSTEM: Comp Mount Type C 3055 ClearAew Way T:(650) 638-1028 Mateo, 0 B CA 440638 -1oz9 ( 888 )- SOL- CITY(765 -2489) www.solarcity.com SHEET: REV. DATE: PV 8 3/7/2013 PAYMENT TYPE: PPA INVERTER POWER —ONE AURORA PVT- 5000 —OUTD— Label Location: (AC), (D), (LC) Per Code: CEC 690.8.A.3 & CEC 690.54, NEC Label Location: (AC), (LC) Per Code: CEC 690.17, NEC 690.14 (4) Label Location: (INV), (AC), (LC), (M) Label Location: (CB) Label Location: (DC), (INV) Label Location: (POI) Label Location: (CB) Label Location: (POI) Label Location: (DC), (INV) Per Code: CEC 690.53. NEC 690.53 Label Location: (C) Label Location: (CB), (DC), (INV) Per Code: CEC 690.35.F I;;UPERTINO Building Department MAR 2 1 2013 REVIEWED FOR CODE COMPLIANCE Reviewed By: (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR `����j 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �. San Mat eo, CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, Labels r:6so)63s -1028 1:(65o)63a -1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE I� SolarCi � (888)SOL- CrFY(765 -2489) www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. mono multi solutions T r • inamount II 17y T&msolar FOR PITCHED ROOF 10 YEAR PRODUCT WARRANTY FOR MODULE AND MOUNTING SYSTEM 5X FASTER TO INSTALL ULTRA LOW RESISTANCE SUITABLE FOR COMBINING PV MODULE EXPERTISE WITH A HIGHLY TSM -230 INNOVATIVE MOUNTING SYSTEM SOLUTION. ® COMPOSITION SHINGLE Trina Solar is introducing Trinamount - the fastest, easiest and least Module dimension expensive way to mount PV modules onto residential and commercial PC /PA05.18 rooftops. With a series of drop -in and quarter -turn connections on a TRAPEZOIDAL METAL ® specialized module frame, this mounting solution installs up to 5 times 230 faster than conventional mounting systems. Trinamount connects STANDING SEAM ROOF ® directly to the module frame, eliminating the need for long rails. By drastically reducing the number of parts, cost of materials and Power Output Tolerance -Prue ( %) installation time, Trinamount offers the optimal solution for residential 0/ +3 and commercial installations. Trinamount II FOR PITCHED ROOF TSM -PC05 / PA05.18 mono multi solutions DIMENSIONS OF PV MODULE TSM -PCOS / PA05.18 ELECTRICAL DATA ® STC TSM -225 TSM -230 TSM -235 TSM -240 TSM -245 Module dimension PC /PA05.18 PC /PA05.18 PC /PA05.18 PC /PA05.18 PC /PA05.18 Peak Power Watts -P, (Wp) 225 230 235 240 245 Power Output Tolerance -Prue ( %) 0/ +3 0/ +3 0/ +3 0/ +3 0/ +3 Maximum Power Voltage -VMV (V) 29.4 29.8 30.1 30.4 30.7 Maximum Power Current -IrwF (AI 7.66 7.72 7.81 7.89 7.98 Open Circuit voltage -Voc (V) 36.9 37.0 37.1 37.2 37.3 Short Circuit Cunent -Isc (A) 8.20 8.26 8.31 8.37 8.47 Module Efficiency Om ( %) 13.7 14.1 14.4 14.7 15.0 Values at Standard Test Conditions STC (Air Mass AM 1.5, Irradiance 1000W /m'. Cell Temperature 25-C). ELECTRICAL DATA ® NOCT TSM -225 TSM -230 TSM -235 TSM -240 TSM -245 Module dimension PC /PA05.18 PC /PA05.18 PC /PA05.18 PC /PA05.18 PC /PA05.18 Maximum Power (W) 164 168 172 175 178 Maximum Power Voltage (V) 26.9 27.1 27.4 27.7 27.8 Maximum Power Current (Al 6.12 6.20 6.27 6.32 6.41 Open Circuit Voltage (V) 33.8 33.9 34.0 34.1 34.2 Short Circuit Current (A) 6.62 6.68 6.70 6.75 6.83 NOCT: Irradiance of 800W /m2. Ambient Temperature 20-C, Wind Speed 1 M /s. MECHANICAL DATA Solar cells Multicrystalline 156 x 156mm (6 inches) Cell orientation 60 cells (6 • 10) Module dimension 1650 x 992 = 40mm (64.95 > 39.05 x 1.57 inches) ti Weight 20.3kg (44.8 lb) ° Glass High transparency solar glass 3.2mm (0.13 inches) Frame Anodized aluminium alloy J -Box IP 65 rated A A Cables / Connector Photovoltaic Technology cable 4.Omm' (0.006 inches'), 1100mm (43.3 inches), MC4 / H4 I -V CURVES OF PV MODULE TSM- 23OPCOS / PA05.18 900 000w /m' 800 - 700 f_BWw'mT�----- -- ---- - -- - --? 600 --- __- ____- __-- _____ -__ ___ << �6Ww /m 400 i- ----� - - - - J 3� 2aow /_ ---- ----------- - - --- -- 200 o°° -- -- - - - - - -- - - - - -�t - 0.44 100' 2000 30.00 40 Voltage (VI CERTIFICATION f E La1/NW 1114 e�� Bs 00'. Ttinasolar � -� Ttinasolar The power behind the panel The power behind the panel TEMPERATURE RATINGS Nominal Operating Cell 46-C ( ±2 °C) Temperature (NOCT) Temperature Coefficient of Pnmx - 0.43 %NC Temperature Coefficient of Vac - 0.32 % / °C Temperature Coefficient of Isc MAXIMUM RATINGS Operational Temperature - 40- +85 :! Maximum System Voltage 1000V DC (IEC)/ 6MVCt /s DC(UL) REVIE I� Max Series Fuse Rating )5A WARRANTY 10 year workmanship warranty 25 year linear perforrnance warranty (Please refer to product warranty, for details) CUPER 1 140 I1,uIIC�IP19 De�38 ent MAR 2 1 2013 D FOR CODE COMPLIANCE awed By: _� ^r 4+ IR =r CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. ® 2011 Trine Solar Limited AN rights reserved. Specifications included in this datosheet are subject to change without notice. SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution is optimized to achieve superior strength and aesthetics while minimizing roof disruption and labor. The elimination of visible rail ends and mounting clamps, combined with the addition of array trim and a lower profile all contribute to a more visually appealing system. SleekMount utilizes modules with strengthened frames that attach directly to Zep standoffs, effectively eliminating the need for rail and reducing the number of standoffs required. In addition, composition shingles are not required to be cut for this system, allowing for minimal roof disturbance. • Utilizes Zep hardware and Zep compatible modules. • Interlock ETL listed to UL 1703 as ground bond means • Ground Zep UL and ETL listed to UL 467 as grounding and bonding device • Full system listed to UL 2703 for grounding • Galvanized aluminum waterproof flashing • Anodized components for corrosion resistance • Applicable for vent spanning functions Components 5/16" Machine Screw 1� Zep Leveling Foot I� Lag Screw Zep Comp Mount Zep Comp Mount Flashing SolarCity. January 2013 SolarCity SleekMountTM - Comp r , . SolarCity. January 2013 Installation Instructions 1 Drill Pilot Hole of Proper Diameter for Fastener Size Per NDS Section 1.1.3.2 2 Seal pilot hole with roofing sealant 3 Insert Comp Mount flashing under upper layer of shingle 4 Place Comp Mount centered upon flashing 5 Install lag pursuant to NDS Section 11.1.3 with sealing washer. 6 Secure Leveling Foot to the Comp Mount using machine Screw 7 Place module CUPERTINO Building Department MAR 2 1 Zull REVIEWED FOR CODE COMPLIANCE Reviewed By: _ X74 /1 Power -PRO= ` kenewoble Enefgy Solutions PVI- 5000 -TL PVI -6000 TL GENERAL SPECIFICATIONS OUTDOOR MODELS Designed for residential and small commercial PV installations, this inverter fills a specific niche in the Aurora product line to cater for those installations producing between 5kW and 20kW. This inverter has all the usual Aurora benefits, including dual input section to process two strings with independent MPPT, high speed and precise MPPT algorithm for real -time power tracking and energy harvesting, as well as transformerless operation for high performance efficiencies of up to 97.1%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size. This outdoor inverter has been designed as a completely sealed unit to withstand the harshest environmental conditions. AURORA • Each inverter is set on specific grid codes which can be selected in the field • Single phase output • Dual input sections with independent MPPT, allows optimal energy harvesting from two sub - arrays oriented in different directions • Wide input range • High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting • Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across the entire input voltage and output power range • Outdoor enclosure for unrestricted use under any environmental conditions • RS -485 communication interface (for connection to laptop or datalogger) • Compatible with PVI - RADIOMODULE for wireless communication with Aurora PVI - DESKTOP Nominal Output Power W 5000 6000 Maximum Output Power W 5000 6000 Rated Grid AC Voltage V 208 240 277 208 240 277 Input Side (DC) Number of Independent MPPT Channels 2 2 Maximum Usable Power for Each Channel W 4000 4000 Absolute Maximum Voltage (Vmax) V 600 600 Start -Up Voltage(Vstart) V 200 (adj. 120-350) 200 (adj.120 -350) Full Power MPPT Voltage Range V 200 -530 200 -530 Operating MPPT Voltage Range V 0.7xVstart -580 0.7xVstart -580 Maximum Current (ldcmax) for both MPPT in Parallel A 36 36 Maximum Usable Current per Channel A 18 18 Maximum Short Circuit Current Limit per Channel A 22 22 Number of Wire Landing Terminals Per Channel 2 Pairs 2 Pairs Array Wiring Termination Terminal block, Pressure Clamp, AWG8 -AWG4 Output Side (AC) Grid Connection Type 10/2W Split -0/3W 10/2W 10/2W Split -0/3W 10/2W AdjustableVoltage Range (Vmin -Vmax) V 183 -228 211 -264 244 -304 183 -228 211 -264 244 -304 Grid Frequency Hz 60 60 Adjustable Grid Frequency Range Hz 57 -60.5 57 -60.5 Maximum Current(lacmax) ARMS 27 23 20 30 28 24 Power Factor > 0.995 > 0.995 Total Harmonic Distortion At Rated Power % <2 <2 Contributory Fault Current— Apw/ARM: 36.25/25.63 36.5/25.81 31.75/22.45 36.25/25.63 36.5/25.81 31.75/22.45 Grid Wiring Termination Type Terminal block, Pressure Clamp, AWG8 - AWG4 Protection Devices Input Reverse Polarity Protection Yes Yes Over - Voltage Protection Type Varistor, 2 for each channel Varistor, 2 for each channel PV Array Ground Fault Detection Pre start -up Riso and dynamic GFDI Pre start -up Riso and dynamic GFDI (Requires Floating Arrays) (Requires Floating Arrays) Output Anti- Islanding Protection Meets UL 1741/IEE1547 requirements Meets UL 1741/IEE1547 requirements Over - Voltage Protection Type Varistor, 2(L,- L, /L, -G) Varistor, 2 (Li - L, /L, -G) Maximum AC OCPD Rating A 35 30 25 40 35 30 Efficiency Maximum Efficiency % 97.1 97.1 CEC Efficiency % 96 96.5 96.5 96 96.5 96.5 Operating Performance Stand -by Consumption WR < 8 < 8 Night time consumption WR < 0.6 < 0.6 Communication User - Interface 16 characters x 2lines LCD display Remote Monitoring (1XRS485 incl.) AURORA- UNIVERSAL (opt.) Wired Local Monitoring (1xRS485incl.) PVI- USS- RS485_232(opt.), PVI- DESKTOP (opt.) Wireless Local Monitoring PVI - DESKTOP (opt.) with PVI - RADIOMODULE (opt.) Environmental Ambient Air Operating Temperature Range °F ( °C) -13 to +140 ( -25 to +601 -13 to +140 ( -25 to +60) with derating above 122 (50) Ambient Air Storage Temperature Range -F ('C) -40 to 176( -40 to +80) -40 to 176( -40 to +80) Relative Humidity %RH 0 -100 condensing 0 -100 condensing Acoustic Noise Emission Level db (A) @1 m < 50 < 50 Maximum Operating Altitude without Derating ft(m) 6560 (2000) 6560 (2000) Mechanical Specifications Enclosure rating NEMA 4X NEMA 4X Cooling Natural Convection Natural Convection Dimensions (H x W x D) in (mm) 41.4 x 12.8 x 8.6 (1052 x 325 x 218) Weight lb (kg) < 59.5 (27.0) < 59.5 (27.0) Shipping Weight lb (kg) < 78 (35.4) < 78 (35.4) Mounting System Wall bracket Wall bracket Conduit Connections Trade Size Kos: (tea x 1/2 ") Tfad " &S' os: (2ea x 1/2 ") +f f " U P E R T DC Switch and (2ea x 1 -1/4; 3 places side, front, rear) h)s d ' - 1�.'Gl4"" places side, front, reaC I N O Rating-(Per Contact) AN 25/600 /600 -3 Ulldln De " Safety # -,.J r,C� arttnent Isolation Level Transformerless (Floating Array) r (Floating Array) Safety and EMC Standard UL 1741,CSA - C22.2 N. 107.1 -01`j 2r"ss C222 N{.�1j0p7.�1 -0}1 Safety Approval cCSA,,,- a - %`t`.^`(CSAu, X03 Warranty a'7Fifii\ f „ Standard Warranty years 10 10 Extended Warranty years lsazo REVIEVVIEUDFOR CODE COMPLIANCE Available Models Standard -With DC Switch - Floating Array 'All data is subject to change without notice PVI - 5000 - OUTD -US PVI - 6000 - OUTD -US Reviewed ay: •• Inverter can apply that much current - Breaker will open • 4 SGroup Certificate of Compliance Certificate: 1841082 Project: 2550432 Issued to: Power -One, Inc 740 Calle Plano Camarillo, CA 93012 USA Attention: Robert White Master Contract: 173688 Date Issued: August 20, 2012 The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. ® ary �twa.L Issued by: Brij Aggarwal, P.Eng. C us PRODUCTS CLASS 531109 - POWER SUPPLIES - Distributed Generation Power Systems Equipment CLASS 531189 - POWER SUPPLIES - Distributed Generation - Power Systems Equipment Certified to U.S. Standards Utility Interactive Inverter, Models PVI- 6000 - OUTD -US, PVI- 6000 - OUTD -US -W and PVI- 5000 - OUTD -US, permanently connected. Notes: 1. All above models in this series may include expansion board with wireless antennae option and will be identified with model designation including " Z" suffix at the end. 2. For details related to rating, size, configuration, etc. reference should be made to the CSA Certification Record, Annex A of the Certificate of Compliance, or the Descriptive Report. DQD 507 Rev. 2012-05 -22 Page: 1 IN CUPERTINO Building Departmeni VAR 2 12013 REVIEWED FOR CODE COMPLIANCE Reviewed By: y�_11;11 I CITY OF CUPERTINO BUILDING PERMIT I BUILDING ADDRESS: 10314 MIRA VISTA RD OWNER'S NAME: SUMNER ROBERT B AND BETTY M OWNER'S PHONE: 4084820227 ❑ LICENSED CONTRACTOR'S DECLARATION License Class Lic. # Contractor Date I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self - insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. CONTRACTOR:SOLARCITY 3055 CLEARVIEW WAY SAN MATEO, CA 94402 PERMIT NO: 13030055 DATE ISSUED: 03 /12/2013 PHONE NO: (650) 638 -1028 BUILDING PERMIT INFO: BLDG r ELECT r PLUMB MECH F RESIDENTIAL r— COMMERCIAL I— JOB DESCRIPTION: INSTALL 22 ROOF TOP FLUSH MOUNTED SOLAR PANELS (5.39KW). UPGRADE (E).ELECTRICAL PANEL TO 150 AMPS, SAME LOCATION. REV #1 -OTC 5/6/2013 -BRACKETS OF THE PANELS TO ROOFTOP CHANGED -OUT REU4sioN#_L__ Sq. Ft Floor Area: I Valuation: $25000 APN Number: 35702022.00 1 Occupancy Type: PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM LAST CALLED INSPECTION. Signature Date I Issued by: ❑ OWNER- BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business& Professions Code). I hereby affirm under penalty of perjury one of the following three declarations: I have and will maintain a Certificate of Consent to self - insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9.18. Signature Date Date: RE- ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without firs6litaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as de .ned'by the Bay Area Air Quality Management District I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Cod. Sections 25505, 25533, and 25534. Owner or authorized agent: Date: CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C.) Lender's Name Lender's ARCHITECT'S DECLARATION I understand my plans shall be used as public records. ABBREVIATIONS ELECTRICAL NOTES INDEX LICENSE JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING PV1 COVER SHEET CA # $88104 , Inst'allin 2 roof to flush— mounted panels _ - 9 �� P P AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN PV2 SITE PLAN C -46 - -10. (5.39 kW); upgrading electrical service panel' BLDG BUILDING POSITION A SIGN WILL BE PROVIDED WARNING � PV3 STRUCTURAL VIEWS with 100A" mQin breaker and 125A main CONIC CONCRETE OF THE HAZARDS PER ART. 690.17. PV4 STRUCTURAL VIEWS panel. ZO C COMBINER BOX 2. EACH UNGROUNDED CONDUCTOR OF THE PV5 UPLIFT CALCULATIONS D DISTRIBUTION PANEL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PV6 THREE LINE DIAGRAM DC DIRECT CURRENT BY PHASE AND SYSTEM PER ART. 210.5. PV7 PV8 ELECTRICAL CALCULATIONS ELECTRICAL LOAD CALCULATIONS Flashing will be painted to match exterior EGC EQUIPMENT GROUNDING CONDUCTOR 3. A NATIONALLY — RECOGNIZED TESTING (E) EXISTING LABORATORY SHALL LIST ALL EQUIPMENT IN Cutsheets Attached ��C), EMT ELECTRICAL METALLIC TUBING COMPLIANCE WITH ART. 110.3. O G SOLAR GUARD METER 4. CIRCUITS OVER 250V TO GROUND SHALL GALV GALVANIZED COMPLY WITH ART. 250.97, 250.92(B) CUTSHEETS ATTACHED O GEC GND GROUNDING ELECTRODE CONDUCTOR GROUND 5. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS GENERAL NOTES HDG HOT DIPPED GALVANIZED OR ENCLOSURES TO THE FIRST ACCESSIBLE DC I CURRENT DISCONNECTING MEANS PER ART. 690.31(E). O Imp CURRENT AT MAX POWER 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN 1. THIS SYSTEM IS GRID — INTERTIED VIA A INVS INVERTERS RELIEF AT ALL ENTRY INTO BOXES AS UL— LISTED POWER— CONDITIONING INVERTER. Isc SHORT CIRCUIT CURRENT REQUIRED BY UL LISTING. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. kVA KILOVOLT AMPERE 7. MODULE FRAMES SHALL BE GROUNDED AT THE 3. PHOTOVOLTAIC SOURCE AND INPUT CIRCUITS AND I kW KILOWATT UL— LISTED LOCATION PROVIDED BY THE INVERTER INPUT CIRCUIT ARE UNGROUNDED. LBW LOAD BEARING WALL MANUFACTURER USING UL LISTED GROUNDING 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED MIN MINIMUM HARDWARE. 5. ALL WORK TO BE DONE TO 2010 CALIFORNIA MIR MIRROR 8. ALL EXPOSED METAL PARTS (MODULE FRAMES, BUILDING CODE. (N) NEW RAIL, BOXES, ETC.) SHALL BE GROUNDED USING 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE NEC NATIONAL ELECTRIC CODE UL LISTED LAY —IN LUGS LISTED FOR THE 2008 NATIONAL ELECTRIC CODE AS AMENDED BY NIC NOT IN CONTRACT PURPOSE. POSTS SHALL BE MADE THE 2010 CALIFORNIA ELECTRIC CODE. NTS NOT TO SCALE ELECTRICALLY CONTINUOUS WITH ATTACHED OC ON CENTER RAIL. P PANEL BOARD 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE PL PROPERTY LINES BONDED WITH EQUIPMENT GROUND CONDUCTORS - g PV PHOTOVOLTAIC AND GROUNDED AT THE MAIN ELECTRIC PANEL. PVC POLYVINYL CHLORIDE 10. THE DC GROUNDING ELECTRODE CONDUCTOR VICINITY MAP S SUBPANEL SHALL BE SIZED ACCORDING TO ART. SCH SCHEDULE 250.166(8) & 690.47. SS STAINLESS STEEL SSD SEE STRUCTURAL DRAWINGS -i STC STANDARD TESTING CONDITIONS --- SWH SOLAR WATER HEATER . TYP UON TYPICAL UNLESS OTHERWISE NOTED moffol UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT A Vmp VOLTAGE AT MAX POWER �. Voc VOLTAGE AT OPEN CIRCUIT t " W WATT - APN:357 -02 -022 3R NEMA 3R, RAINTIGHT h` t REV BY DATE COMMENTS i ° ' �•� REV A CHI 5/6/13 Changed mounting hardware & module to YingIi250 CONFIDENTIAL – THE INFORMATION HEREIN JOB NUMBER: J B -9 SO 14O`Y o0 PREMISE OWNER: Aft DESCRIPTON: DESIGN: `� ►r �� CONTAINED SHALL NOT BE USED FOR THE ANYONE EXCEPT INC., SUMNER, ROBERT CE Amy Chiang �. MARKET: MODULES NOR SHALL LL NOR SHALL IT BE DISCLOSED IN WHOLE OR IN IN WHOLE REST 22 YINGLI YL250P -29b YGE 60 10314 MIRA VISTA RD y 5.5 KW PV Arra 'I/, SolarCity PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH C U P E R TI N O CA 95014 . PROJECT MANAGER: MOUNTING SYSTEM: 3055 Clearview Way San Mateo, CA 94402 THE SALE AND USE T, THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN SC L —Foot: 1 La — Downslo e PAGE NAME: SHEET: REV DAIS PAYMENT TYPE PPA I POWER —ONE AURORA PVT- 5000 —OUTD— # PERMISSION OF SOLARCITY INC. S 408 482— 0227 COVER SHEET PV 1 a 5/6/2013 T:(65o) 638 -lozs F:(65o) 638 -1oz9 ( 888)- SOL- CIfY(765- 2489)www.solan;ity.com 10314 Mira Vista Rd Fence PITCH: 21 ARRAY PITCH: 21 MP1 AZIMUTH: 270 ARRAY AZIMUTH: 270 MATERIAL: Comp Shingle STORY: One PITCH: 21 ARRAY PITCH: 21 MP2 AZIMUTH: 90 ARRAY AZIMUTH: 90 MATERIAL: Comp Shinale STORY. One i Cf'4MIn1In u 3 0 (E) UTILITY METER & WARNING LABEL leV INVERTER W/ INTEGRATED DC DISCO Front Of House a & WARNING LABELS A C PV4 80'toPL © DC DISCONNECT & WARNING LABELS r PV3 � AC © AC DISCONNECT & WARNING LABELS 0 o Q JUNCTION BOX Flashing will be pointed to match exterior O DC COMBINER BOX & WARNING D DISTRIBUTION PANEL &WARNING Lc LOAD CENTER & WARNING LABELS O DEDICATED PV SYSTEM METER CONDUIT RUN ON EXTERIOR - -� CONDUIT RUN ON INTERIOR B D 8' to PL — GATE /FENCE PV3 PV4 --- INTERIOR EQUIPMENT SITE PLAN N T N r Scale: 3/32" = 1' W E 01' 10' 21' S CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE JOB NUMBER JB- 9501404 OO PREMISE OWNER: AHr SUMNER, ROBERT DESCRIPTION: SUMNER RESIDENCE DESIGN: Amy Chiang `�[;rr�' BENEFIT LL ANYONE EXCEPT SOLWHOLE INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN MARKET: REST MODULES 22 YINGLI n25oP -29b YGE 60 10314 MIRA VISTA RD 5.5 KW PV Array solarcity. PART TO OTHERS EXCEPT I OUTSIDE ON RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: MOUNTING SYSTEM: C U P ER TI N O, CA 95014 . THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN SC L —Foot: 1 La — Downslo e P PAGE NAME: SHEET: REV: DATE: 3055 CIearview Way San Mateo, CA 94402 PERMISSION OF SOLARgTY INC. PAYMENT TYPE: PPA INVERTER: POWER —ONE # AURORA PM- 5000 —OUTD— S (408) 482 -0227 SITE PLAN PV 2 a 5/6/2013 T:(650)638 -1028 F:(650) 638 -1029 ( 888)- SOL- CIfy(765 -2489) www.solarcity.com A SIDE VIEW OF MP1 SOLAR PANEL TTACHED WITH MODULE CLAMPS, �' -16 BOLTS, AND J" NUT SOLARCITY SOLAR RAIL & BOLT LEVELING FOOT (E) COMP. SHINGLE L —FOOT FLASHING (E) ROOF DECKING a" DIA LAG BOLT (2 —j" EMBED, MIN) (E) RAFTER CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. #-5Rrr;2" = 1' JDB NUMBER: JB- 9501404 00 MARIU- MODULES RESI 1 (22) YINGLI A YL250P- MANAGER: PAYMENT TYPE MOUNTING SYSTEM: SC L —Foot: INVERTER: POWER —ONE 1 Laa — (E) 2x4 RAFTER ® 24" O.C. (E) 1x6 RIDGE BOARD (BLOCKING) (E) 2x4 (E) 2x4 CEILING JOIST ® 16" O.C. RAFTER: 2x4 SUPPORT: 2x4, 1x6 MAX SPAN: 8' -7" --------------- -- INSTALLATION ORDER (1) LOCATE RAFTER, MARK HOLE LOCATION, AND DRILL PILOT HOLE. (2) SEAL PILOT HOLE WITH . POLYURETHANE SEALANT. (3) INSERT L —FOOT FLASHING. (4) PLACE THE LEVELING FOOT. G(5) INSTALL LAG WITH SEALING WASHER. PREMISE OWNER: AHJ SUMNER, ROBERT YGE 60 10314 MIRA VISTA RD CUPERTINO, CA 95014 AURORA PVI- 5000 — OUTD —1 S (408) 482 -0227 4' -0" DESCRIPTION: SUMNER RESIDENCE 5.5 KW PV Array PAGE NAME: STRUCTURAL VIEWS (E) 2x4 RAFTERS 24" SPACING FRONT VIEW OF MP1 SCALE: 1/2" = V DESIGN: 84 Amy Chiang 1--%s ' 3055 ClearAew Way SHEET: REV: DALE San Mateo, CA 94402 T:(650) 638 -1028 F:(650) 638 -1029 PV 3 a 5/6/2013 (888)- SOL -CrrY (765 -2489) www.solarcity.com Moou RO sui � SIDE VIEW OF MP2 SOLAR PANEL ATTACHED WITH MODULE CLAMPS, r " -16 BOLTS, AND r NUT SOLARCITY SOLAR RAIL & BOLT LEVELING FOOT (E) COMP. SHINGLE L -FOOT FLASHING (E) ROOF DECKING A" DIA LAG BOLT (2 —j" EMBED, MIN) (E) RAFTER STANDOFF Scale: 1 1/2" = 1' (E) 2x4 RAFTER 24" O.C. (E) 1x6 RIDGE BOARD (E) 1x8 (E) 2x4 (E) 2x4 CEILING JOIST ® 16" O.C. RAFTER: 2x4 SUPPORT: 2x4, 1 x6, 1 x8 MAX SPAN: 9' -1" 4' -0" (E) 2x4 RAFTERS 24" SPACING FRONT VIEW OF MP2 SCALE: 1/2" = 1' CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE.EXCEPT SOLMCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S THE�SALEnAND USE OF IN THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. INSTALLATION ORDER PREMISE OWNER: AHJ, DESCRIPTION: SUMNER ROBERT SUMNER RESIDENCE 10314 MIRA VISTA RD 5.5 KW PV Array CUPERTINO, CA 95014 PAGE NAME: 408 482— 0227 S ) STRUCTURAL VIEWS DESIGN: Amy Chiang (�) LOCATE RAFTER, MARK HOLE LOCATION, AND DRILL PILOT HOLE. MODULES 22 YINGLI # YL250P -29b YGE 60 h4hal (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. MOUNTING SYSTEM: SC L —Foot: 1 La — Downslo e 3055 Cleanriew Way San Mateo, CA 94402 T:(650) 638 -1028 F:(650) 638 -1029 ( s8s)- sol- crrY(�6s- z489)www.w�anty.mm (3) INSERT L —FOOT FLASHING. INVERTER POWER—ONE # AURORA PVI- 5000 —OUTD— (4) PLACE THE LEVELING FOOT: (5) INSTALL LAG WITH SEALING WASHER. 4' -0" (E) 2x4 RAFTERS 24" SPACING FRONT VIEW OF MP2 SCALE: 1/2" = 1' CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE.EXCEPT SOLMCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S THE�SALEnAND USE OF IN THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: J B- 9501404 0o PREMISE OWNER: AHJ, DESCRIPTION: SUMNER ROBERT SUMNER RESIDENCE 10314 MIRA VISTA RD 5.5 KW PV Array CUPERTINO, CA 95014 PAGE NAME: 408 482— 0227 S ) STRUCTURAL VIEWS DESIGN: Amy Chiang ``bog, ���SolarCity Mme; REST MODULES 22 YINGLI # YL250P -29b YGE 60 h4hal PROJECT MANAGER: MOUNTING SYSTEM: SC L —Foot: 1 La — Downslo e 3055 Cleanriew Way San Mateo, CA 94402 T:(650) 638 -1028 F:(650) 638 -1029 ( s8s)- sol- crrY(�6s- z489)www.w�anty.mm SHEET: REV: DATE; PV 4 o 5�6�2013 N T TYPE PPA INVERTER POWER—ONE # AURORA PVI- 5000 —OUTD— UPLIFT CALCULATIONS INPUT VARIABLES CALCULATIONS AND VALUES Required Variables . Design wind pressures based upon: Mean Roof Height: 26 ASCE 7 -05 Chapter 6 Wind Loading Exposure Category: B Equation 6.5.13.3: Component and Cladding Elements Basic wind speed (or city in the future): 85 Wind pressure P = qh *Cn *G Importance factor (1 for residential): 1 6.5.10: Velocity pressure qh = 0.00256 *Kz *Kzt *Kd *V ^2 *1 Roof shape: Pitched From Table 6 -3: Roof Angle (degrees): 21 Kz = 0.76 Roof zone: 3 Contiguous sq. feet of array: 35.96 From Figure 6-4: Kzt = 1 Least width of the building: 373.95 Obstructed wind flow? True From Table 6-4: Kd = 0.85 Local Topographical Features (choose "standard "or refer to pictures right, and below) From figure 6 -1: V =85 Type of hill: None Hill height (h) (ft): From table 6 -1: I - 1 Slope of hill (degrees): Horizontal distance from hilltop to house (x): From Velocity Pressure Equation Height from bottom of hill to mean roof height (z): qh = 11.95 From Figure 6 -19B Design Wind Pressure P (Ibs. per sq. ft.) = qh *Cn *G Cn (uplift) _ -2.88 Pd (downforce pressure) = 10.16 Cn (down) = 1 Pu (uplift pressure) = 29.25 From 6.5.8.1 G = 0.85 Max TributaryArea Feet Inches Arrays consist of modules in portrait and landscape X (E -W distance between standoffs) = 0 48 TRINA SOLAR # TSM- 245PC05 Y (N -S distance between standoffs) = 0 30 Amax (sq. ft.) = 0.5 *L *X Staggered Penetrations = Yes L (length of panel in ft. perpendicular to rail) 5.41 Module Rail Max. Span /Cantilever (in) = r 48 23 X= 4 Y = 2.5 Max Uplift Force on a Single Standoff L= N/A Pmax (Ibs.) = Amax *Pu Amax = 10.83 316.68 Dead Load Calculations Factor of safety = FI *D *NI /Pmax DL (Ibs /sq. ft.) = (Mm +Mh) /(L*W) 5/16 x 5 in. = Lag size and length 1196.95 = Capacity (Ibs) of 1 lag (NDS) L (length of modules) 5.41 1 = NI (number of lags per standoff) W (width of modules) 3,25 3.78 = Factor of safety Mm (weight of modules) 44.8 Point Load Calculations Mh (weight of hardware per module) = 6 PL (Ibs) = Amax *DL DL = 2.88 31.22 CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: J B -9.SO 1404 OO CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET MODULES: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN REST PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE PERMISSION OF SOLARCITY INC. MOUNTING SYSTEM: SC L -Foot: 1 Lag - Downslope INVERIfk POWER —ONE # AURORA PVI- 5000 —OUTD tEMISE OWNER: MIt SUMNER, ROBERT 10314 MIRA VISTA RD CUPERTINO, CA 95014 (408) 482 -0227 SUMNER RESIDENCE 5.5 KW PV Array PAGE NAME UPLIFT CALCULATIONS DESIGN: Amy Chiang a SHEET: REV: DATE PV 5 a 5/6/2013 ■ 3055 Cleamiew Way San Mateo, CA 94402 T:(650) 638 -1028 F:(650) 638 -1029 (888)- SOL -CrrY (765 -2489) www.solarcity.com BOND (N) #8 GEC TO (E) WATER PIPE AT N 125A MAIN SERVICE PANEL Inv 1: DC Ungrounded INV 1 —(1)I R, ON "RW I-50DD- WTD-US IAM " —(22) "PN�q � �wP�c N4,4unm,el,�r.,,,e CA # 888104 PANEL WITH IRREVERSIBLE CRIMP �N� 100/2P MAIN CIRCUIT BREAKER C -46, C -10 Panel Number: SQUARE D INV 2 Vpmax:30.4 Meter Number: 1006679287 MODULE CURRENT RATINGS ARE SHOWN AS Isc AND Imp IN Overhead Service Entrance INV 3 Twp nr, cTPimrc InvmTiripp nr TWV cwr_I I I imp nler_aeu MAIN SERVICE PANEL (T) SWARE Bne" 30I 1/2P. 2 Spoon PV BACKFEED BREAKER. AC (1) AWC 111), 111), THWAI -2. Black O 3 (1) Aric po, THMN -2, Rea (1)AWWG p% THNN -2, White NEUTRAL Vmp =240 VAC Imp = 20.83AAC ........ (1 A. IHM -z Greco ..... EGC /GEC . -.() ) CapaaH R 3/4' .QA� ............ Inverter I IND POWER —ONE IRORA PM- 5000 — OUTD —US r- - - - - - - - - - - - — - - - - - - - - - - - - - - - - - - - - - I I I n --C'C -- -- — — — — — — — — — — — — ( I ) Conduit Kit; 3/4' EMT DO NOT ADJUST MIN. ACTIVATION VO TAGE I 1 String(s) Of 11 On MP 1 DO NOT ADJUST MIN. ACTIVATION VO TAGE I C_ — 1 String(s) Of 11 On MP 2 EGC DC O1 :.V Voc Vmp 422.4 VDC Isc 8.79 = 334.4 VDC Imp = 8.24 GFP /GFCI O2 ......................... ............................... N__ ( 2) A1WG ra PV WE Bleak (1) AW0 #B, Solid Bare Capper EGC Voc Vmp r- - - - - - - - - - - - — - - - - - - - - - - - - - - - - - - - - - I I I n --C'C -- -- — — — — — — — — — — — — ( I ) Conduit Kit; 3/4' EMT DO NOT ADJUST MIN. ACTIVATION VO TAGE I 1 String(s) Of 11 On MP 1 DO NOT ADJUST MIN. ACTIVATION VO TAGE I C_ — 1 String(s) Of 11 On MP 2 EGC DC O1 (2) AWC p0, PV WIRE, Blod (1) AWC A Solid Bum capper EGC Voc Vmp 422.4 VDC Isc 8.79 = 334.4 VDC Imp = 8.24 ADC ADC O2 ......................... ............................... N__ ( 2) A1WG ra PV WE Bleak (1) AW0 #B, Solid Bare Capper EGC Voc Vmp = 422.4 VDC Isc = 8.79 = 334.4 VDC Imp= 8.24 ADC ADC CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: J B -9 501404 OO PREMISE OWNER AHJ: DESCRIPTION: DESIGN: `�64,` CONTAINED SHALL NOT BE USED FOR THE SUMNER, ROBERT SUMNER RESIDENCE Amy Chiang 01 = '�►�, MARKET. REST MODULES 22 YINGLI YL250P -29b YGE 60 BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 10314 MIRA VISTA RD 5.5 KW PV Array y Sofa PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH CUPERTINO, CA 95014 PROJECT MANAGER MOUNTING SYSTEM: 3055 Cleandew Way San Mateo, CA 94402 THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN SC L -Foot: 1 La - Downslope PAGE NAME SHEET: REV: DATE PAYMENT TYPE PPA INVERTER: POWER-ONE # AURORA Pvl- SOOO -oum- PERMISSION OF SOLARCITY INC. 408 482 -0227 s THREE LINE DIAGRAM PV 6 a 5/6/2013 T:(650) 638 -1028 F:(650) 638 -1029 1 (888)- SOL-CITY (765- 2489)wwwsolarcity.com a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.15(B)(16). c. Evaluate conductor temperature at terminations per 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current *1.25. All string terminations are rated at 90' C. 2. OCP Sizing per Art 690.8(B)(1) a. Round up to next size per Art 240.4(B) 3. Conductor Sizing per Art 690.8(0)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.15(8)(16). c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current *1.25. All branch terminations are rated at 75' C min. ------------------------------------------ 4. OCP Sizing a. Round up to next size per Art 240.4(B) ------------------------------------------ 5. Conductor Sizing per Art 690.8(B)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.15(B)(16). c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire Berated for conditions of termination must be >= continuous current *1.25. All inverter output terminations are rated at 75' C. 6, OCP Sizing a. Round up to next size per Art 240.4(6) 7. Conductor Sizing per Art 690.8(B)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.15(B)(16). c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= continuous current *1.25. All inverter output terminations are rated at 75' C min. CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: J B- 9501404 00 MARKET: RESI PROJECT MANAGER: PAYMENT TYPE MODULES- MOUNTING SYSTEM: SC L -Foot: INVERTER POWER -ONE ELECTRICAL CALCULATIONS Module: YL250P -29b YGE 60 226.2 Inv Pwr W PTC StrLen Voltage Drop Calculations Version 59.11 Inverter 1: L22Yingli wer -One PVI- 5000 -S 96.5% 5,000 4,802 11 Vdrop = (Imp) * (2 * Length) * (Resistance) / (Vmp) Module: I Imp (A) Max. Length (ft) Wire Inverter 2: String: 8.24 30 CAW 10 at Max Ave Hi: 85 deg F Module: Vdrop = (8.24 A * 60 ft * 0.00124 Ohms) / 302 V = 0.20% Inverter 3: Branch: 8.24 60 C AWG 10 at Max Ave Hi: 85 deg F Module: Vdrop = (8.24 A * 120 ft * 0.00124 Ohms) / 302 V = 0.41% Inverter 4: Total voltage drop in DC conductors Inverter: 20.83 10 1 D AWG 08 1 at 240V Total: EM11111, modules Total Inv Pwr 5,000 4,802 PTC Vdrop = (20.83 A * 20 ft *0.00078 Ohms) / 240 V 0.14% Photovoltaic Module Electrical Specifications: Total STC 5,500 0.83 0 1 DAWG 08 at 240V Combined 20.83-T- Voc= 38.4 V deg F deg C Vdrop = (20.83 A Oft * 0.00078 Ohms) / 240 V 0.00% Vmp= 30.4 V Record Low Temp: 16 - 8.88888889 Total voltage drop in AC conductors = 0.14% Ise= 8.79 A Max Average Hi Temp: 85 29.44444444 Total voltage drop in AC and DC conductors = 0.74% Imp= 8.24 A Tvoc= - 0.12672 V /deg C Power -One Strings: Individual MPPT rise= 5.274 mA/deg C String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc data Branch Circuit Type A 1 -way wire length: 60 It Power -One PVI- 5000 -S 1 strings per branch 1 1 strings per branch 2 11 Yingli YL250P -29b YGE 60 Inverter Min Vdc Input 120 Vdc 11 modules per series string 11 modules per series strin Voc= 422.4 V Min Vmp at Max Temp: 302 Vdc Voc= "" ' TV 422.4 V Vmp= 334.4 V Max Voc at Min Temp: 470 Vdc Vmp= 334.4 V 334.4 V Ise= 8.79 A Inverter Max Vdc Input: 600 Vdc Ise= 8.79 A 8.79 A Imp= 8.24 A Max String Size: 14 Imp= 8.24 A 8.24 A Icont= 10.99 A Art 690.8(A)(1) 1 -way wire length: 30 It Icont= 10.99 A 10.99 A Art 690.8(A)(1) 1.a Conductor C AWG 10 PV Wire 2.a Conductor 1: C AWG 10 PV Wire Conductor 2: C AWG 10 PV Wire Conductor 1: Conductor 2: Icont * 1.25 = (Amps) 13.73 Icont * 1.25 = (Amps) 13.73 13.73 30 deg C ampacity = 40 30 deg C ampacity = 40 40 1.b Icont= (Amps) 10.99 2.b Icont= (Amps) 10.99 10.99 Start ampacity 40 Start ampacity 40 40 Temperature derate ( % =F) 0.76 Temp. derate ( % =F) 0.76 0.76 Conduit fill derate ( %_ #) 1 Cndt. fill derate ( % = #) 0.8 0.8 Derated ampacity 30.40 Derated ampacity 24.32 24.32 Term 1 Term 2 1.c Icont *1.25= (Amps) 13.73 Temp table 75degC 75degC Ampacity 40 2.c Icont *1.25= (Amps) 13.73 13.73 Ampacity 35 35 1.d Icont * 1.25 = (Amps) 13.73 2.d EGC C AWG 10 C AWG 10 Art. 250.122 OCP size = 15 OCP size = 15 15 Inverter Type A Output Combined Inverter Output Power -One PVI- 5000 -S 1 -way wire length: 10 ft Service Voltage= 240 Volts Icont= 20.83 A Art 690.8(A)(1) Total Inverter Power= 5,000 Icont = # of inverters *max inverter Nameplate Watts 1 -way wire length: current Art 690.8(A)(1) 0 ft 3.a Icont *1.25 = (Amps) 26.04 A Art 690.8(B)(1) OCP size = 30 A Art. 240.6(A) Icont = (Amps) 20.83 3.b Conductor D AWG 08 THWN -2 at 90 deg C: Table 310.16 4.a Icont *1.25 = (Amps) 26.04 A Art 690.8(B)(1) Icont * 1.25 = (Amps) 26.04 OCP size = A Art. 240.6(A) 4.b Conductor Icont * 1.25 = (Amps) THWN -2 at 90 deg C: Table 310.16 26.04 30 deg C ampacity = 55 3.c Icont= (Amps) 20.83 Start ampacity 55 30 deg C ampacity = 55 IF Temperature derate ( % =F) 0.91 4.c Icont= (Amps) 20.83 Conduit fill Berate ( %_ #) 1 Start ampacity 55 Derated ampacity 50.05 Temp. derate ( % =F) Cndt. fill derate ( % = #) 0.91 1 3.d Icont *1.25= (Amps) 26.04 Ampacity 50 Derated ampacity 50.05 3.e EGC /GEC = D AWG 08 Art. 690.47(C)(3), 250.166(B) 4.d Icont *1.25= (Amps) 26.04 Ampacity 50 PREMISE OWNER A& SUMNER, ROBERT -29b YGE 60 10314 MIRA VISTA RD CUPERTINO, CA 95014 1 LOCI - Downslope AURORA PVI- 5000 - OUTD -+ (408) 482 -0227 DESCRIPTION: SUMNER RESIDENCE 5.5 KW PV Array PAGE NAME: ELECTRICAL CALCULATIONS DESIGN: Amy Chiang SHEET: REV: DATE- PV 7 a 5/6/2013 SolarCi r� 3055 Cleamew Way San Mateo, CA 94402 T:(650) 638 -1028 F:(650) 638 -1029 (888) -SOL -CITY (765 -2489) www.solarcity.com CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: J B- 9501404 00 MARKET: MODULES REST 22 YINGLI # YL250P -29b YGE 60 PROJECT MANAGER: MOUNTING SYSTEM: SC L —Foot: 1 La — Downslope PAYMENT TYPE INVERTER: PPA POWER -ONE # AURORA PVI- 5000 -OU PREMISE OWNER: AHJ: SUMNER, ROBERT 10314 MIRA VISTA RD CUPERTINO, CA 95014 (408) 482 -0227 DESCRIPTION: SUMNER RESIDENCE 5.5 KW PV Array PAGE NAME: ELECTRICAL LOAD CALCULATIONS DESIGN: Amy Chiang SoiarCi w ' ` ` - --- 3055 Clearview Way SHEET: REV. DATE San Mateo, CA 94402 4 T:(650) 638 -1028 F:(650) 638 -1029 PV Q a 5/6/2013 (888) -SOL -CITY (765 -2489) www.solarcity.com NEC 2008 220.82 - Residential Load Calculation Version 2.0 L1 /L2 240 V NEC 220.82(B) "The general calculated load shall be not less than 100% of the first 10 kVA plus 40% of the remainder of the following loads..." NEC 220.82(B)(1) "The calculated floor area shall not include open porches, garages, or unused ... spaces..." Floor Area 1,443 square feet x 3VA/sq ft 4,329 VA NEC 220.82(B)(2) °1500 volt- amperes for each 2 -wire, 20- ampere small appliance branch circuit and each laundry branch circuit..." Small Appliance Circuits 3 circuits x 1500VA /circuit 4,500 VA Laundry Circuits 1 circuits x 1500VA /circuit 1,500 VA Bathroom Circuits 1 circuits x 1500VA /circuit 1,500 VA NEC 220.82(B)(3) "The nameplate rating of all appliances... ranges, wall- mounted ovens, counter - mounted cooking & 220.82(B)(4) units... clothes dryers that are not connected to the laundry branch circuit... [and] water heaters" 2P Breaker VA Oven 30 5,760 Dryer 50 9,600 Spa 0 Pool 0 Pool 0 0 0 0 0 0 15,360 total VA Total of non air -conditioning loads: 27,189 total VA First 10 kVA of load at 100% 10,000 Remainder of load at 40% 6,876 Adjusted total of non air - conditioning load 16,876 VA NEC 220.82(C) "Heating and air - conditiong load..." 2P Breaker VA A/C Equipment Unit #1 30 5,760 A/C Equipment Unit #2 0 Total of A/C Loads and All Other Loads: 22,636 total VA Total Proposed Calculated Load: 94.32 Amps J B -9561882 SolarCity ©copyright SolarCity 2012 JOB NUMBER: J B- 9501404 00 MARKET: MODULES REST 22 YINGLI # YL250P -29b YGE 60 PROJECT MANAGER: MOUNTING SYSTEM: SC L —Foot: 1 La — Downslope PAYMENT TYPE INVERTER: PPA POWER -ONE # AURORA PVI- 5000 -OU PREMISE OWNER: AHJ: SUMNER, ROBERT 10314 MIRA VISTA RD CUPERTINO, CA 95014 (408) 482 -0227 DESCRIPTION: SUMNER RESIDENCE 5.5 KW PV Array PAGE NAME: ELECTRICAL LOAD CALCULATIONS DESIGN: Amy Chiang SoiarCi w ' ` ` - --- 3055 Clearview Way SHEET: REV. DATE San Mateo, CA 94402 4 T:(650) 638 -1028 F:(650) 638 -1029 PV Q a 5/6/2013 (888) -SOL -CITY (765 -2489) www.solarcity.com Label Location: (C) Per Code: CA Fire Guidelines Label Location: (DC) (INV) Per Code: CEC 690.14.C.2 Label Location: (DC) (INV) Per Code: CEC 690.53 Label Location: (DC) (CB) Per Code: CEC 690.17 Label Location: (DC) (INV) Per Code: CEC 690.5(C) Label Location: (AC) (POI) Per Code: CEC 690.14.C.2 Label Location: (AC) (POI) Per Code: CEC 690.54 Label Location: (AC) (POI) Label Location: (AC) (POI) Per Code: CEC 690.17 Label Location: (POI) Per Code: CEC 690.54; CEC 690.17 Label Location: (D) (POI) Per Code: CEC 690.64.B.4 Label Location: (POI) Per Code: CEC 690.64.B.4 Label Location: (DC) (INV) Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR `lb *@4 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED San Mateo, CA 99902 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, SC - CA Label Set ���� T:(650)638 -1028 F:(650) 638 -1029 EXCEPT IN CONNECTION MATH THE SALE AND USE OF THE RESPECTIVE /l� �OIarC'� (888)- SOL- CITY(765 -2489) www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. The SolarCity L -Foot with Eco- Fasten GreenFasten flashing optimizes strength, performance and aesthetics while structurally attaching solar panels to composition shingle roofs. This engineered connection uses Eco - Fasten's patented, IAPMO- certified "green fasten" technology to achieve a watertight seal. 6000 series aluminum offers superb structural and fatigue strength, which in conjunction with anodization offers excellent corrosion resistance even in coastal environments. • IAPMO -ES- certified product for waterproofing — Tested in accordance with ICC standards • Tested in accordance with UL 441— Waterproofing for rooftop penetrations • Anodized for long term corrosion resistance and best aesthetics • No shingle cutting required • Fast and error -proof installation reduces overall impact on roof • Rail is attached using Stainless Steel Fasteners Installation Instructions 1. Drill pilot hole in rafter 2. Seal pilot hole with roofing sealant 3. Insert Eco- Fasten flashing under upper layer of shingle 4. Place SolarCity LFoot 5. Install lag with sealing washer Components A. 5/16" Lag Screw B. Stainless Steel + EPDM Sealing Washer C. SolarCity L -Foot D. Eco- Fasten Green Fasten Flashing .a AR.a ¢? `SolarCity. 1!y tU,6017S nos1 rnnn -r® AURORA Nominal Output Power W 5000- 6000 Maximum Output Power W 5000 6000 Rated Grid AC Voltage V 208 240 21 71 208 240 277 - - ___ ANois -_; -- ----- -- -- -- -- ---- - -- - -- - --- --- - --- - ------ ----- --- --- - - -- ----..._._. - - -_ _____ - -_ Number of Independent MPPT Channels - ft(m) 2 2 Maximum Usable Power for Each Channel W 4000 4000 Absolute Maximum Voltage (Vmax► V 600 600 Start - Up Voltage(Vstart) V 200,(adj.120 -350) 200 (adj.120 -350) Full Power MPPT Voltage Range V 200 -530 200 -530 Operating MPPT Voltage Range V 0.7xVstart -580 0.7xVstart-580 Maximum Current (ldcmax) for both MPPT in Parallel A 36 36 Maximum Usable Current per Channel A 18 18 Maximum Short Circuit Current Limit per Channel A 22 22 Number of Wire Landing Terminals Per Channel 25/600 2 Pairs 2 Pairs Array Wiring Termination Terminal block, Pressure Clamp AWG8 AWG4 Isolation Level Transformeriess (Floating Array) Grid Connection Type - - __. 10/2W Split0 /3W 10/2W 10/2W Split -0/3W 10/2W AdjustableVoltage Range (Vmin -Vmax) V 183 7228 211-264 244304 183-228 211-264 244304 Grid Frequency Hz 60 60 - - -._ ........__ Adjustable Grid Frequency Range Hz ----- 57 -60.5 57 -60.5 Maximum Current (lacmax) ARMS 27 23 20 30 28 24 Power Factor A Wood-, > 0.995 > 0.995 -- - - - - - - -' - Tot al Harmonic Distortion At Rated Pow_ er - % -- -- _ <2 _._... _._._. <2 -- Contributory Fault Current"" Aok/ARres. - 36.25/25 63 36.5/25.8 1 31 75/22.45 36 25/25 63 36.5/25 81 ! 31.75/22.45 Grid Wiring Termination Type '*Inverter an apply that much current- Breaker will open _ Termmal block, Pressure ClampAWG8 AWG4 iptection:Derlcis ' -_- _ Input --- Reverse Polarity Protection - Yes Yes Over - Voltage Protection Type - -- - ....... .. ..... .... -- - Varistor, 2 for each channel - -.._. _.. Varistor, 2 for each channel -- --- --- - _... ........... PV Array Ground Fault Detection Pre start-up Riso and dynamic GFDI Pre start-up Riso and dynamic GFDI (Requires FloatingArrays),. _ (Requires Floatmg,Arrays) Output �.__ Anti- Islanding Protection _....... ------ - --- - - -- - ------- Meets UL 1741/IEE1547 requirements ! Meets UL 1741 /IEE1547 requirements --- -- -- - ------ - - Over- Voltage Protection Type - Varistor,2(_Li-Lz /L,-G) - -- - r -- - Varistor_2(L,- L, /L,- G_)... - - Maximum AC OCPD Rating A 35 30 25 40 35 30 REi t Maximum Efficiency - - - - ------------------------------ - - - -- rerems...... % ee- ....____��. - - - -- 97.1 - ---- - _ ....:-- �c ec c � oa c 97.1 --- --- - - -- -- - - - -- --- -- --- - - ---- na oa c oa c Ambient Air Operating Temperature Range - - - ° - - - of CC) - - - -- -13 to +140 ( -25 to +60) - --with denting Ambient Air StorageTemperatureRange °F(°C) _ ___ - 40to176 (-40 to - _________- _-- __- ___ -_-(_ _ _ - 40to176(- 40to ±80)__- _- _ -_ -___ Relative Humidit............... %RH 0 100 condensin4 0 100 condensing____ - - ___ ANois -_; -- ----- -- -- -- -- ---- - -- - -- - --- --- - --- - ------ ----- --- --- - - -- ----..._._. - - -_ _____ - -_ .......................... ............... . --- - -- - -- -- - Maximum 0 eratin Altitude without Dentin - ft(m) - -- -- -- ---- -- ------ -- --- -- - - -- -- -- -- -- --- -- -- -. - - - .:. 6560 (2000) --- --------------------- - ._..._.. - - - 6560 (2000) Enclosure rating i NEMA4X NEMA4X _ _ Cooling - - . ... _ - Natural Convection - -- - -- -- - -- ....... -. , Natural Convection - ----- -- .. - - Dimensions (H x W x D) in (mm) 41A x 12.8 x 8.6 (1052x 325 x218) Weight - _ ..lb (kg). - - - < 59.5 (27.0) < 59.5 (27.0). ShippingWeight lb(kg) <78(35.4) <78(35.4)_ _ Mounting System _ _ - Wall bracket Wall bracket Conduit Connections Trade Size Kos: (tea x 112) Trade Size Kos (tea x 1/2') and (tea x 1 -1/4°, 3 places side, front, rear)..: and -(2ea x 1 1/4, 3 places side, front rear)_._. DC Switch Rating (Per Contact) AN 25/600 25/600 ; Isolation Level Transformeriess (Floating Array) Transformerless (Floating Array) Safetya- n dEMCSt_a. n- d ard UL 1741,CSA C22.2 N. 107.1-01 U_L.Nil- M - C22.2N. 107.1 -01 - .. .. .. - -.. _....._ Safety Approval CSA , CSA�, Standard Warranty years 10 10 Extended Warranty years 1 S & 20 15&20 A Wood-, Standard -With DC Switch -Floating Array PVI- 5000- OUTD -US PVI -6000 OUTD -US •All data is subject to change without notice '*Inverter an apply that much current- Breaker will open -_- _ c CSA Group Certificate of Compliance Certificate: 1841082 Master Contract: 173688 Project: 2550432 Date Issued: August 20, 2012 Issued to: Power -One, Inc 740 Calle Plano Camarillo, CA 93012 USA Attention: Robert White The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. ® Brig Agg rwab Issued by: Brij Aggarwal, P.Eng. C us PRODUCTS CLASS 531109 - POWER SUPPLIES - Distributed Generation Power Systems Equipment CLASS 531189 - POWER SUPPLIES - Distributed Generation - Power Systems Equipment - Certified to U.S. Standards Utility Interactive Inverter, Models PVI- 6000 - OUTD -US, PVI- 6000 - OUTD -US -W and PVI- 5000- OUTD -US, permanently connected. Notes: 1. All above models in this series may include expansion board with wireless antennae option and will be identified with model designation including " —Z" suffix at the end. 2. For details related to rating, size, configuration, etc. reference should be made to the CSA Certification Record, Annex A of the Certificate of Compliance, or the Descriptive Report. DQD 507 Rev. 2012 -05 -22 Page: 1 YGE 6 0 YL255P -29b YL250P -29b CELL SERIES YL245P -29b YL240P -296 W YL235P -29b YINGLI SOLAR` U.S. Soccer Powered by Yingli Solar COMPANY Yingli Green Energy (NYSE:YGE) is one of the world's largest fully vertically integrated PV manufacturers. With over 4.5 GW of modules installed globally, we are a leading solar energy company built upon proven product reliability and sustainable performance. Founded in 1998, Yingli Green Energy serves customers through our U.S. subsidiary, Yingli Americas, co- headquartered in New York and San Francisco. We are the first renewable energy company to sponsor the U.S. National Soccer teams and the FIFA World Cup". PERFORMANCE Industry leading in -house manufacturing of polysilicon, ingots, wafers, cells and modules ensures tight control of our material and production quality. - High performance, multicrystalline solar cells deliver a module series efficiency of up to 15.6 %, reducing installation costs and maximizing the kWh output per unit area. Tight positive power tolerance of -OW to +5W ensures modules are delivered at or above rated power, improving system performance through the reduction of module mismatch loss. QUALITY & RELIABILITY Robust, corrosion resistant aluminum frame independently tested to withstand wind and snow loads of up to 50 psf and 113 psf, respectively, ensuring mechanical stability. - Manufacturing facility certified to IS09001 Quality Management System standards. - Module packaging optimized to protect product during transportation and minimize on -site waste. WARRANTIES Leading limited power warranty* ensures 91.2% of rated power for 10 years, and 80.7% of rated power for 25 years. - 10 -year limited product warranty. * In compliance with our warranty terms and conditions. QUALIFICATIONS & CERTIFICATES UL 1703 and ULC 1703, UL Fire Safety Class C, CEC, FSEC, ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007, SA8000 C RED ® : (P TO TTwEcgsrooukr) iii.._+ �2 400 YINGLISOLAR.COM /US I Yingli Americas YGE 60CELL SERIES ELECTRICAL PERFORMANCE Module type 600V. YL255P -29b YL250P -29b YL245P -29b YL240P -29b YL235P -29b Power output P... W 255 250 245 240 235 Power output tolerances AP... W Hailstone impact 1 in (25 mm) at 51 mph (23 m/s) -0/ +5 PV wire /43.31 in(1100 mm) 12 AWG /0244 in (62 mm) Plug connector Module efficiency q. % 15.6 15.3 15.0 14.7 14.4 Voltage at P... V­' V 30.6 30.4 30.2 29.5 29.5 Current at P... I— A 8.32 8.24 8.11 8.14 7.97 Open- circuit voltage V« V 38.7 38.4 37.8 37.5 37.0 Short- circuit current 1.. A 8,88 8.79 8.63 8.65 8.54 STC: 1000W /m2 irradiance, 25oC cell temperature, AM 1.59 spectrum according to EN 60904 -3 Average relative efficiency reduction of 5.0% at 200W /m2 according to EN 60904 -1 Operating Electrical parameters at Nominal Power output P... W 184.7 181.1 177.9 174.3 170.7 Voltage at P.., V..p V 27.9 27.6 27.2 26.6 26.6 Current at P... Im,n A 6.63 6.56 6.54 6.56 6.42 Operreircuit voltage Ve. V 35.7 35.4 34.5 34.2 33.8 _Short- circuit current I.. A 7.19 7.12 6.99 7.01 6.92 NOCL open - circuit operating rell temperature at 800W /m' inadiance, 20 °C ambient temperature, 1 m/s wind speed THERMAL CHARACTERISTICS Nominal operating cell temperature NoeT °C 46./-2 Temperature coefficient of P... y % / °C -0.45 Temperature coefficient of V.. 9v.° % / °C -033 Temperature coefficient of 1" a % / °C 0,06 Temperature coefficient of V.tx 0v % / °C -0.45 OPERATING CONDITIONS Max. system voltage 600V. Max. series fuse rating 15A -- --- -- - -- - -- --- ---- - - - - -- - -- Limiting reverse current - -- -- - 15A Operating temperature range -40 to 194 °F (40 to 90°C) Max. static load, front (e.g., snow and wind) 113 psf (5400 Pa) Max. static load, back (e.g., wind) 50 psf (2400 Pa) Hailstone impact 1 in (25 mm) at 51 mph (23 m/s) CONSTRUCTION MATERIALS From cover (materiaVtype /thickness) Low -iron glass / tempered / 3.2 mm Glass may have anti - reflective coating Cell (quantity/materiaVtype /dimensions/ 60 / polysilicon / multicry nalline / area /# of busbars) 156 mm x 156 mm / 243.3 cm2 / 2 or 3 Encapsulant (material) Ethylene vinyl acetate (EYA) Frame (material /color) ' Aluminum alloy / anodized silver or black -- --- --------- --'- ------- box (protection degree) ------ zIP65 Cable(typeAength /gauge /outside diameter) PV wire /43.31 in(1100 mm) 12 AWG /0244 in (62 mm) Plug connector Amphenol / H4 / IP68 _- - - -__- (manufactumr /type /protection degree) The specifications in this datasheet are not guaranteed and are subject to change without prior notice. This datasheet complies with EN 50380:2003 requirements. Yingli Green Energy Americas, Inc. info@yingliamericas.com Tel: +1 (888) 686 -8820 YINGLISOLAR.COM /US I NYSENGE 0 Yingli Green Energy Holding Co. Ltd. I YGE60CeII5eries2013 EN_201301 V01 Powered by YINGLI GENERAL CHARACTERISTICS Dimensions(L/W /H) 64.96 in(1650mm)/38.98 in (990 mm)/ 1.57 in (40 mm) Weight 42.1 Ibs(19.1 kg) PACKAGING SPECIFICATIONS Number of modules per pallet Number of pallets per 53' container Packaging box dimensions (UW /H) Box weight Units: Inch (mm) 26 34 67 in (1700 mm) / 45 in (1150 mm) / 47 in 0190 mm) 117716s(534 kg) 3.94000) .47(12) F SECTION B-B 1.26 (32) QWaming: Read the Installation and User Manual in its entirety before handling, installing, and operating Yingli modules. Our Partners YINr LAR we U.S. Soccer Powered by Yngli Solar