10080189 CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 10483 MIRA VISTA AVE CONTRACTOR:YIN CHAN PERMIT NO: 10080189
OWNER'S NAME: YIN CHAN 15159 MONTALVO RD DATE ISSUED: 11/052010
O. ..;R'S PHONE: 4088366070 SARATOGA,CA 95070 • PHONE NO:
❑ LICENSED CONTRACTOR'S DECLARATION r r
BUILDING PERMIT INFO: BLDG T ELECT PLUMB
License Class Lic.II
MECH r RESIDENTIAL r COMMERCIAL .,
Contractor Date
I hereby affirm that I am licensed under the provisions of Chapter 9 JOB DESCRIPTION:NEW TWO-STORY(3760SQ),GARAGE(579SQ)&
(commencing with Section 7000)of Division 3 of the Business&Professions LANDSCAPE
AREA(4517SQ)
Code and that my license is In full force and effect.
hereby affirm under penalty of perjury one of the following two declarations:
I have and will maintain a certificate of consent to self-insure for Worker's
Compensation,as provided for by Section 3700 of the Labor Code,for the
performance of the work for which this permit is issued.
I have and will maintain Worker's Compensation Insurance,as provided for by
Section 3700 of the Labor Code,for the performance of the work for which this
permit is issued. Sq.Ft Floor Area: Valuation:$800000
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is APN Number:35704080.00 Occupancy Type:
correct I agree to comply with all city and county ordinances and state laws relating
to building construction,and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We)agree to save
indemnify and keep harmless the City of Cupertino against liabilities,judgments, PERMIT EXPIRES IF WORK IS NOT STARTED
costs,and expenses which may accrue against said City in consequence of the
granting of this permit Additionally,the applicant understands and will comply WITHIN 180 DAYS OF PERMIT ISSUANCE OR
with all non-point source regulations per the Cupertino Municipal Code,Section 180 DAYS FROM LAST CALLED INSPECTION.
9.18.
Si^-^cure Date Issued b:y!.,/ DateV'(' - %7--G
r
LI OWNER-BUILDER DECLARATION
I hereby affirm that I am exempt from the Contractor's License Law for one of RE-ROOFS:
the following two reasons: -• All roofs shall be inspected prior to any roofing material being installed.If a roof is
I,as owner of the property,or my employees with wages as their sole compensation, installed without first obtaining an inspection,I agree to remove all new materials for
will do the work,and the structure is not intended or offered for sale(Sec.7044, inspection.
Business&Professions Code) Signature of Applicant: Date:
I,as owner of the property,am exclusively contracting with licensed contractors to
construct the project(Sec.7044,Business&Professions Code).
ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER
I hereby affirm under penalty of perjury one of the following three At
declarations:
I have and will maintain a Certificate of Consent to self-insure for Worker's HAZARDOUS MATERIALS DISCLOSURE
Compensation,as provided for by Section 3700 of the Labor Code,for the
performance of the work for which this permit is issued. I have read the hazardous materials requirements under Chapter 6.95 of the
I have and will maintain Worker's Compensation Insurance,as provided for by California Health&Safety Code,Sections 25505,25533,and 25534. I will maintain
compliance with the Cupertino Municipal Code,Chapter 9.12 and the Health&
Section 3700 of the Labor Code,for the performance of the work for which this Safety Code,Section 25532(a)should I store or handle hazardous material.
permit is issued. Additionally,should I use equipment or devices which emit hazardous air
I certify that in the performance of the work for which this permit is issued,I shall contaminants as defined by the Bay Area Air Quality Management District I will
not employ any person in any manner so as to become subject to the Worker's maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the
Compensation laws of California If,after making this certificate of exemption,1 Health&Safety Code,Sections 25505,25533,and 25534.
become subject to the Worker's Compensation provisions of the Labor Code,I must Owner nt:"
forthwith comply with such provisions or this permit shall be deemed revoked.ADate: I ( / sl �,l7/0
(,rl
APPLICANT CERTIFICATION CONSTRUCTION LENDING AGENCY
I certify that 1 have read this application and state that the above information is
correct.I agree to comply with all city and county ordinances and state laws relating 1 hereby affirm that there is a construction lending agency for the performance of work's
to building construction,and hereby authorize representatives of this city to enter for which this permit is issued(Sec.3097,Civ C.)
i• he above mentioned property for inspection purposes.(We)agree to save Lender's Name
I. .nify and keep harmless the City of Cupertino against liabilities,judgments, Lender's Address
costs,and expenses which may accrue against said City in consequence of the
granting of this permit Additionally,the applicant understands and will comply
with all non-point source rept ' n's per, upertino Municipal Code,Section ARCHITECT'S DECLARATION
9.18.
j
_ " Date ( l/ç//o
I understand my plans shall be used as public records.
Signature
Licensed Professional
ri �•l 'e'. ,•;-,-},a:--_,..-- ".-.t. a-`ery.�, ,-. .,�. -�•n,� �,r ; r=• A^,., ,r.^, „�, y���". � � ,;'FGf•� ,;f r� T:iv��
� ., ,6. ^ r -3� �y n� r� _ � +.-� ,��� .'�. �! ti�T9,'•X' ry c•^c RG '� ��" � :iry > � �p .int .•h,.�'liA?� r2'ti,.; +��r'. ..,‘1:
y�,7 Fti�,�t��.r' �i��k o
�,,.. JJ J_ J •LJJ1 J CU .) Q". .. - ,� , . -
"o,r. L ..„.„.....c...„,„�..;.,,,pc:-.;�,t+ .. ::...�....- *:-_. le:'-`2'.";.. .,d°�' .,...{, h 1;e1 ,. L,>-1 .r.- .,fe• !?rn... yy' S' 1•._ �-�> •,,,..- "+e y,er--) `^� ` '
File Edit Actions Details Links Favorites Help ard
. •
Perrnit Information- --•-- --- --- -- - -------• -- ,,-Location Information----.._-____— ___ .r.---_-- — -._--_
�. [Address' 10483MIRAVISTAAVE OK
Permit Number” 1.0080189 . .., ;
j [10080189 . • it " - i _ _._ {�
Status' rC- ;"iClo ed?ng{ ?g v I City/State/Zip CUPERTINO CA 95014 ' (�Back
Master Number I Notes I 71. ; APN 35704080.00 4`
Project ! (.( ,-)1 i; Unit 1 . - I c Contractors ,1
t _ _ :.__ _ _ _ _
1 •---•- - Fees
Apply Date' (08/26/2010 a �! Operator patg -0!l:'nerEntityInformation -_ _ `.-_ - - _ - 1.0
Permit Issue Date 111/05/2010 Operator raciC
_ T (Owner Name' YIN CHAN I � g Plan Reviews
Certificate Issued 11/04'/2011 ! Operator [garys
—_' h Use Default III
Certificate Type ICC CERTIFICATE OF COMPL ', Inspections
• Address Home-15159 MONTALVO RD , "
Certificate Number I I it [ i l,g'=r,Print Permit
-- �
City/State/Zip !SARAOGA 1 CA{ I95070 I
f ,Adjustments
Permit' a Property l Zoning , Applicant I[ Contractor_I! Defined Fields 1[..Si Holds
•-Permit Details ----- - . --- -•- • - - . Purpose/Special Conditions - - --- - -- --- I[E4CopyPermit
Permit Type' I1R3SFDW gPI.IEW TWO—STORY(3760SQ),CARAGE(579SQ) & LANDSCAPE i
AREA RHA(4517SQ) ® Close Permit
i !SINGLE FAMILY DWELLING I (
Usage Class" I II/III B. CI "SEE NOTES"' ! Overrides
111/III B,IV-HT,V-B NEW - Supplemental Fields
Applied Value' I 800000 I FILE LOCATED IN FLEA ROOK BOX 16 r
14 Notes
SQUARE FT. 1 4340 '.
' I t Attachments
Calculated Value I 0[-�
•
! I
' US C-404 Type 1101 Q
I NEW:SFD,DETACHED
Permit Form' IAUTOPERM -PERMIT v 1 .
i I I
Ownership 1 •Private v !
Project Size I STANDARD •STANDARD vl :i [QAdd Default Text •
r.
< ,m 1 is I
i
Permit issued 11/0512010
-
Enter permit status +OUR;
CITY OF CUPERTINO
5 ITEMS OF 5 PERMIT RECEIPT OPERATOR: suew
COPY # : 1
Sec: Twp: Rng: Sub: Blk: Lot:
APN • 35704080. 00
DATE ISSUED • 11/05/2010
RECEIPT # • BS000011931
REFERENCE ID # . . . : 10080189
SITE ADDRESS • 10483 MIRA VISTA AVE
SUBDIVISION
CITY • CUPERTINO
IMPACT AREA
OWNER • YIN CHAN
ADDRESS • 15159 MONTALVO RD
CITY/STATE/ZIP . . . : SARATOGA, CA 95070
RECEIVED FROM • YIN CHAN
CONTRACTOR LIC # *OWNER*
COMPANY • YIN CHAN
ADDRESS • 15159 MONTALVO RD
CITY/STATE/ZIP . . . : SARATOGA, CA 95070
TELEPHONE
FEE ID UNIT QUANTITY AMOUNT PD-TO-DT THIS REC NEW BAL
1BCBSC VALUATION 800, 000 . 00 32 . 00 0 . 00 32 . 00 0. 00
1BCONSTAXR FLAT RATE 1 . 00 558. 42 0 .00 558.42 0. 00
1BSEISMICR VALUATION 800, 000 . 00 80. 00 0 .00 80 . 00 0. 00
1PLLONGR SQUARE FEET 4, 340 . 00 564 .20 0 . 00 564 .20 0. 00
1R31NSP SQUARE FEET 4, 340 . 00 3303 .72 0 .00 3303 .72 0. 00
1R3PLNCK SQUARE FEET 4, 340 .00 2924 . 36 2924 .36 0 . 00 0. 00
TOTAL PERMIT : 7462 .70 2924 .36 4538 . 34 0. 00
METHOD OF PAYMENT AMOUNT REFERENCE NUMBER
CHECK 4, 538 .34 1146
TOTAL RECEIPT : 4, 538. 34
CITY OF CUPERTINO
ITEM 1 OF 1 PERMIT RECEIPT OPERATOR: suew
COPY # : 1
Sec : Twp: Rng: Sub: Blk: Lot:
APN • 35704080 . 00
DATE ISSUED • 08/26/2010
RECEIPT # • BS000011295
REFERENCE ID # . . . : 10080189
SITE ADDRESS • 10483 MIRA VISTA AVE
SUBDIVISION
CITY • CUPERTINO
IMPACT AREA
OWNER • YIN CHAN
ADDRESS • 15159 MONTALVO RD
CITY/STATE/ZIP . . . : SARATOGA, CA 95070
RECEIVED FROM • YIN CHAN
CONTRACTOR LIC # *OWNER*
COMPANY • YIN CHAN
ADDRESS • 15159 MONTALVO RD
CITY/STATE/ZIP . . . : SARATOGA, CA 95070
TELEPHONE
FEE ID UNIT QUANTITY AMOUNT PD-TO-DT THIS REC NEW BAL
1BCBSC VALUATION 800, 000 .00 32 . 00 32 .00 0 . 00 0. 00
1BCONSTAXR FLAT RATE 1 . 00 558 . 42 558 .42 0 . 00 0 . 00
1BSEISMICR VALUATION 800, 000 .00 80 . 00 80 .00 0 . 00 0. 00
1PLLONGR SQUARE FEET 4, 340.00 564. 20 564 .20 0 . 00 0. 00
1R3INSP SQUARE FEET 4, 340 . 00 3303 . 72 3303 .72 0 . 00 0 . 00
1R3PLNCK SQUARE FEET 4, 340.00 2924. 36 0 .00 2924 . 36 0. 00
TOTAL PERMIT : 7462 .70 4538 .34 2924 . 36 0. 00
METHOD OF PAYMENT AMOUNT REFERENCE NUMBER
CHECK 2, 924 . 36 #1067
TOTAL RECEIPT : 2, 924 . 36
INSPECTION WORK LOG - ONE PER PAGE DETAIL FORMAT PAGE-001
PRINTED ON 04/01/13
PERMIT NUMBER: 10080189 10483 MIRA VISTA AVE CUPERTINO
PERMIT TYPE: 1R3SFDW SINGLE FAMILY DWELLING
USAGE CLASS: II/III B, II/III B, IV-HT,V-B NEW
SPECIAL :NEW TWO-STORY(3760SQ) ,GARAGE(579SQ) & LANDSCAPE
PERMIT :AREA(4517SQ)
CONDITIONS:
AND NOTES : **SEE NOTES**
PARCEL ID: 35704080 .00
LOT: BLOCK:
SUBDIVISION:
OWNER NAME: YIN CHAN
OWNER ADDRESS: 15159 MONTALVO RD
CONTRACTOR ID: OWNER
CONTRACTOR NAME: YIN CHAN
CONTRACTOR PHONE: * NOT ON FILE *
SUB-CONTRACTOR ID: 25529
SUB-CONTRACTOR CATEGORY: BC
SUB-CONTRACTOR NAME: DAVID BRANON CONSTRUCTION INC
SUB-CONTRACTOR PHONE: (408)778-3696
SUB-CONTRACTOR ID: 32595
SUB-CONTRACTOR CATEGORY: BC
SUB-CONTRACTOR NAME: BOBCAT BUSTER
SUB-CONTRACTOR PHONE: (408) 687-7194
SUB-CONTRACTOR ID: 29950
SUB-CONTRACTOR CATEGORY: BC
SUB-CONTRACTOR NAME: LOS GATOS GLASS
SUB-CONTRACTOR PHONE: (408) 354-1523
SUB-CONTRACTOR ID: 28153
SUB-CONTRACTOR CATEGORY: BC
SUB-CONTRACTOR NAME: SAS ROOTER & PLUMBING
SUB-CONTRACTOR PHONE: (510) 468-8436
SUB-CONTRACTOR ID: 26871
SUB-CONTRACTOR CATEGORY: BC
SUB-CONTRACTOR NAME: EXECUTIVE ROOFING
SUB-CONTRACTOR PHONE: (408) 458-6044
SUB-CONTRACTOR ID: 33063
SUB-CONTRACTOR CATEGORY: BC
SUB-CONTRACTOR NAME: ROSA CONSTRUCTION & DRYWALL
SUB-CONTRACTOR PHONE: (408) 848-2622
INSPECTION TYPE: 516 FINAL BUILDING
INSPECTION AREA:
SCHED DATE: 11/02/11 INSPECT TIME:
CONTACT INFO:
INSPECTOR: GST STREAM, GARY
INSTRUCTIONS: P.M. LATE - HENRY 691 3724 (408)
COMMENTS:
RESULTS: PASS FAIL CANCEL RE-FEE FAIL CODE:
NOTES:
PRIOR INSPECTION RESULTS:
101 FOUNDATION 11/17/10 P BG
101 FOUNDATION 11/16/10 I BG
106 SEWER & WATER 06/22/11 P BG
106 SEWER & WATER 06/21/11 I BG
106 SEWER & WATER 06/20/11 C BG
106 SEWER & WATER 06/17/11 C GST
202 UNDERFLOOR PLUMBING 11/30/10 P LS
203 UNDERFLOOR MECHANICA 11/30/10 P LS
204 UNDERFLOOR FRAME 11/30/10 P LS
301 ROUGH PLUMBING 04/15/11 P BG
301 ROUGH PLUMBING 03/31/11 P BG
302 TUB & OR SHOWER 04/22/11 P GST
302 TUB & OR SHOWER 04/15/11 P BG
302 TUB & OR SHOWER 04/12/11 F BG
302 TUB & OR SHOWER 04/08/11 F GST
303 ROUGH MECHANICAL 03/31/11 P BG
304 ROUGH ELECTRICAL 03/31/11 P BG
305 FRAME 03/31/11 P BG
307 INSULATION 04/05/11 P BG
308 SHEETROCK 04/12/11 P BG
309 EXTERIOR LATH 04/15/11 P BG
309 EXTERIOR LATH 01/20/11 C WRONG INSPECTION BG
310 INTERIOR LATH 05/02/11 P BG
311 SCRATCH COAT 04/22/11 P GST
313 ROOF NAIL 01/20/11 P BG
315 EXT SHEAR 01/20/11 P BG
316 INT SHEAR 01/20/11 P BG
404 ELECTRIC METER RELEA 09/08/11 P GST
404 ELECTRIC METER RELEA 09/07/11 F GST
501 FINAL ELECTRICAL ENE 10/25/11 P GST
502 FINAL PLUMBING ENERG 10/25/11 P GST
503 FINAL MECHANICAL ENE 10/25/11 P GST
504 FINAL BUILDING ENERG 10/25/11 P GST
505 FINAL ELECTRICAL 10/25/11 P GST
506 GAS TEST 04/15/11 P BG
507 FINAL PLUMBING 10/25/11 P GST
508 FINAL MECHANICAL 10/25/11 P GST
510 FINAL PLANNING 10/17/11 P GDS
516 FINAL BUILDING 11/02/11 P GST
516 FINAL BUILDING 10/25/11 F GST
CommunityPlus V8 . 1 PAGE NUMBER: 1
DATE: 04/01/2013 Client Name MODULE : libNotes
TIME: 08 : 04 : 03 Permitting Notes
SELECTION CRITERIA: Permit Number = 10080189
Note Date/Time Date of Record Operator Note Code Reminder Date
2011-11-04 07 :35: 56 11/04/2011 patg
FAXED GAS MTR RLS TO PGE(GSTREAM
FINALLED 11/2/2011)
2011-09-08 16 :32 :20 09/08/2011 patg
FAXED TO PG&E ELECTRIC MTR RLS
2010-10-27 17 :02 : 33 10/27/2010 SylviaM
E-MAILED COMMENTS TO YIN CHAN @
CARLSONCHAN@YAHOO.COM RESUBMIT 5 COPIES
TO THE BLDG DEPARTMEMT
2010-09-16 16 : 50: 09 09/16/2010 suew
Hi Carlson,
Attached are the plan check comments for
10483 Mira Vista Rd #10080189. Please
make the changes and re-submit 6
complete sets of plans with the written
responses for all departments attached
to each set of plans .
If you have any questions, please
contact the Building Department at
408-777-3228 or by .email
suew@cupertino.org.
Sincerely,
Susan Winslow
Bldg Dept .
Original Message
From: Carlson Chan
[mailto:carlsonchan@yahoo.com]
Sent: Thursday, September 16, 2010 3 : 19
PM
To: Building
Subject: 10483 Mira vista comments
Hi,
I am the owner if 10483 Mira vista.
I would like to request a soft copy of
the plan review comments.
Regards
Carlson Yin Chan
2010-09-14 16 :29 : 59 09/14/2010 SylviaM
CommunityPlus V8. 1 PAGE NUMBER: 2
DATE: 04/01/2013 Client Name MODULE : libNotes
TIME: 08 :04 : 03 Permitting Notes
SELECTION CRITERIA: Permit Number = 10080189
Note Date/Time Date of Record Operator Note Code Reminder Date
LEFT MESSAGE W/ Y CHAN TO CALL BACK AND
PROVIDE FAXD # OR E-MAIL ADDRESS OR
WANTS TO PICK UP COMMENTS
2010-08-26 14 :30: 29 08/26/2010 suew
THIS APN# IS ASSOCIATED WITH 22331
SANTA
PAULA AVE & 10483 MIRA VISTA RD. THE
LOTS WERE DIVIDED. 10483 MIRA VISTA IS
NEW-WE USED 35704080 . 10483 AS THE APN
# .
YIN CHAN WAS MADE AWARE WHEN HE
SUBMITTED PLANS TO BUILDING THAT THE
PLANNING APPEAL PERIOD IS NOT OVER TILL
9/7/10 . APPEALS CAN BE FILED UP TO END
OF DAY ON THE 7TH. HE WAS INFORMED
THAT
IF THERE IS AN APPEAL, HE COULD LOSE
HIS
PLAN CK FEE IF NOT ALLOWED TO BUILD AS
PER PLANS HE SUBMITTED. SUEW.
2010-08-26 14 : 15: 53 08/26/2010 patg
10483 IS MIRA VISTA & APN IS SAME FOR
22331 SANTA PAULA; LOTS SPLIT
Date:4/1/2013
Permit Holds
Permit Location Address Reason Entered Released
Number Operator Operator
10080189 10483 MIRA VISTA AVE DO NOT PRINT-MST BE PKD UP AS OWNR/BLDR RELEASED PER BOB S 11/16/10 SUEW patg TraciC
10483 MIRA VISTA AVE NO 516 UNTIL LANDSCAPE INSTALLATION RELEASED PER BOB S 11/16/10 SUEW piug bethe
10483 MIRA VISTA AVE NO BLDG FINAL NEED QUITCLIAM RELEASED PER BOB S 11/16/10 SUEW SylviaM SylviaM
10483 MIRA VISTA AVE NO FINAL-ND SUBCONTRACTORS'BSL INFO RELEASED PER BOB S 11/16/10 SUEW patg patg
10483 MIRA VISTA AVE NO FINALS SUBMIT QUITCLAIM TO PW RELEASED PER BOB S 11/16/10 SUEW SylviaM SylviaM
10483 MIRA VISTA AVE OK TO RELEASE RELEASED PER BOB S 11/16/10 SUEW counter George
10483 MIRA VISTA AVE OK TO RELEASE RELEASED PER BOB S 11/16/10 SUEW plug George
10483 MIRA VISTA AVE PROVIDE ARBORIST LETTER RE:EXISTING RELEASED PER BOB S 11/16/10 SUEW plug TraciC
Page 1
•
r-- r .-.,�,,• ar; ,�- ..._ " -�:c,.: : _ . , = .:= •
:F.,4...4,......7, ,,.;,_"....:.,._
"..--} iYi '1_- S' x� 4 yL%L.:::74,•,..;77,-•• am . 1a 'tt.1 .: v..1.,-;,,,,-_,
'.1, "`• -`3" �:r..-�... }
.
La-t:F: -- Y -- r` L.Y ., 4''„_ .`",j'AArrt' .Je.« ;`,'?'".14.j ' 9X c r:i �,SJ�_ P,m7:l + Nqy,. e.Vit - j : .1 ,.1-q54,r_- . •�, i1.5174•}" ear ru'!
Flt 11J 1�Midi • all- . '`i . �r ,.„.:,,,z.,r” ��1f4k `Z 'tt `�� % -...,1;:,,e-
,,rVin '''' 4p" ...t., < -�S .z't 't ;.ttri. .,1xrt },r.S4'i': •=.4t,..0.5 •1
File Edit Details Links Tools Favorites Help `
Permit Information------- - - -----• ----- - - _ -—_.— - — — - — — — -- - — -- • ,
Permit Number 10080189 I Status Open - j r OK
APN 35704080.00 Back
Address 10483 MIRA VISTA AVE ! -
Owner Name YIN CHAN t ' a Print Reviews j
I
Review Stop ; Revision Date In Due Date 1 Date Out I Status I Time 1 Reviewer Notes I Contractor ID I Sent Tc. ..1 I S;SE V .V..-i, k ;%ti? tr.¢4a rQ8/2612O1'U 091��;Q`1 01U 1+1''7Q51 ;6 . . e�" -F tr. M. - `:x-•,i �^ ra.,", ' ti NV:,:j [4\gi,Out
BLDG 1 1'08/26/2010 09/10/2010 !09/14/20101N_ I 0.00 ARNOLD I"
I BLDG 2,10/13/2010 .10/20/2010 1 10/27/2010 ;.4 0.001 LARRY r" __— i _ _
--L----•• - - --- '�Reset
[FIPE ^--;_ 1'08/26/2010 109/10/2010 109/02/2010 IN _ _I 1DOUG �" 1 Plan Review Information -. -. . Plan Review Notes-- --- -- -- - - - ._- ----- —.
E-mail 1
Review Stop I NEW TWO—STORY(3760SQ),GARAGE(579SQ) & LANDSCAPE ..1 ; ' 1
Revision --1I . Continuous •
i' AREA(4517SQ) ' ttiHolds
•
Reviewer — t'Supplemental Fields
Date In 08/26/2010 I1:J Time In '
Project Size STANDARD I Default Days 1 141 i
Notes
Due Date F09/10/2010 4l:•i : EI Attachments
Date Out 11105/2010 P_-.!.11 Time Out
Status A-APPROVED ' ' '
Status Date _ 4'.°1 i
•
Time Spent
f { •ti i1 i
Contractor -•_t l 1
i
Sent To !ASSESSOR -COUNTY ASSESSOR i • •
Sent By ISUEW I
•
• 1 Y I '
- inVP1
- _
-,. ' .. -;�,E• _�S 1 ., --t
.,
� rtif�4' ^ ;,+3y .V.67:+1,,,--_,11,.,%; " -yy. ', ,«v :r6r,-4--,E :.4; th .�-t3 c.1trmo"i•F ,16. '," .z,; fid }^' ,y-'.fi. i `w .47t ,tM.C . K xbj , rE. 'rP, t -$4 '. ^� , j r<,-1�aig `1 .. : x.e:4417 - ,, ..5- 1 _. .� • ' ,.2.r .e ';n, . rr'. • 1 :/70- -.0f!.• " '.= .;1.,. .- — S"iriaA ; "
.-- :L] L
File Edit Details Links Tools Favorites Help .
Permit Information-------- -- ---" -- -- _--- ___..._----- --- -------T-_� _ .---- --•- - = t r
Permit Number 10080189 Status Open • - 1 us.OK ,j
APN 35704080.00 j -
Address 10483 fvfIFIA VISTA AVE 4%Back
r
Owner Name YIN CHAN I I : 0Print Reviews
r
i
i Review Stop ' Revision Date In i Due Date Date Out Status ' Time I Reviewer Notes I Contractor ID I Sent Tct^I In
FIRE 210/13/2010 ;10/20/2010 10/19/2010 LA_ —_� 0.00 DOUG t
- _. -- — - --- - Ou
PLANNING _ 3'11/04/2010_11/11/2010 .11/04/2010 A I___0.001PIU_ _ , _ I
PLANNING _ _ _210/13/2010 110/20/2010 10/21/2010_ ••N _ I _0.0o PIU -- _�- __ - ._ ' — Reset
PLANNING 1 08/26/2010 09/10/2010 09/14/2010 ;hl___ i — O.00IPIU _—_" ;
( - --_ — - ill - 1 1)•`-'.J ir:jb�Fees
Plan Review Information, ---- - •- -Plan Review Notes -- --- - --- ---- - -- - .--._.-_.--_ - -
_ LIE-mail
J
Review Stop ;FIRE -FIRE DISTRICT REVIEW NEW TWO—STORY(3760S0) ,GARAGE(579S0) & LANDSCAPE A 1 :
r-- AREA(4517SQ) ! • ► HOIds
Revision i 11 Continuous
Reviewer !DOUG • Supplemental Fields ,
Date In 108/26/2010 10;1 Time In 1 -
Project Size 1STANDARD ' Default Days 14 1 Notes
Due Date 109/10/2010 !'_:::g Attachments
:
Date Out 09/02/2010 1 Time Out 14:08
Status IN •NOT APPROVED - ' .
Status Date 109/02/2010 11011
Time Spent j I _` I E
Contractor
Sent To I ' ' 1 .
Sent By suew
_
..,.i... '+'�.. . . r� .,. _.'.e.- v..._ - . - � ,... �.• . ` e*.~� .ip.. ,� 10,.r 4-",,,,,:, ,ta. .„4,..` e _ t. ,��vt- T ,t;
i e ' P"i ._may am ''7?_ B
.
,. ,.... _
-eg
•
•.7r • r .Yt.. . - s T• ,_ 's, ',."'.."4",... . ta, , vC�' -• , f ,,.--,..p.,-..•,.--4,:.
. r ,. -,.$r" 4-. � .J IA, VVi- .-.. F0X _a73 _i. k . c'hY " 6 ; �srg,
J r-P J it....
�,^-t ..n•_..-- . „c 4_,. .,..., „_-� .. � •f- 4 - d ' ,17- —I .. sr:', .w5”;, I:7,4 ,Y:, IV.Al �.4.:• ?v� ,.,r * ,
.• � ,r1 _• � � z9',ti ,' Ny.£ tri.ersrr '�r airr,,: _x�� ".�e,a •-sws�'ti•�- - L M ,��. ms.1''..rA.��. .9.3rht, :5 ..4�7 _ dt. 4�. v = 1..,;:, rap Li , '--".-
FileFile
Edit Details Links Tools Favorites Help -
-Permit Information ------ - - - - - - - _ �____-- -__. _ -_ ------ _.. _.-- -- -- -._.
Permit Number 10080189 Status Open -- ' ! 'rj OK P
A.PN 35704080.00 i i
4o Back
Address [L483 MIRA VISTA AVE `
Owner Name YIN CHAN a Print Reviews 1
Review Stop Revision Date In : Due Date ; Date Out 1 Status Time i Reviewer Notes i Contractor ID ; Sent Tc_" LtIn
� i i
PUBWORKS 1:08/26/2010 109110/2010 -109/09/2010 N l^� 0.001 CHAD _1,, ,r_� _ ! trjOut
PUBWORKS 2!1 011 31201 0 _ 10/20/2010_ 110/18/2010 'N_ O.O0 CHAD — - ,, _„_. -___
-
SANITARY __ _ 210/1312010 10/20/2010 10118/2010 'tJ_ _ __ _ 0.0_OiNICHOL 1
,SANITA•RY 1108/26/2010-__109/1012010__J09/08/2010 IN j 0.00 NICHOL --L ;j 7 Reset
3111103/2010 111103/2010 I 11/03/2010 P 0.00 NICHOL � !
SANITARY _ _ --, I _-- __ 1 ,. i_ �1� 'j� Fees
Plan Review Information-- --_-- .--- _- ._------- ---------- --_ ,-Plan Review•Notes. _ -_. _.._. — -J j `�E mail
Review Stop PLANNING -PLANNING DEPARTMENT'REVIEW i� .NELT TWi7-STORY(37605Q) GARAGE(5795Q) 5 LANDSCAPE. l^�l i . �.
Revision L 1 Continuous •' AREA('4517SQ-)-YIN CHp.N•-WAS TOLD THAT THE'L'E•LA.NNING.APPEAL:'._ r•;1 I I. i Holds
PERIOD WAS NOT OVER TILL 9/7/10 AND IF THERE WERE APPEALS
Reviewer PIU - 1 • HE COULD HOLD UP HIS PLANS IN BLDG AND POSSIBLY LOSE PLAN I I't Supplemental Fields I
Date In 108/26/2010 I1;r?Ij Time In 116:33_ I CK FEES. HE SAID HE WAS WILLING TO TAKE THAT CHANCE_ ll
I •. 1_1 Notes t
Project Size 1STANDARD Default Days i 1411 • 11, UPDATE PRIVACY PROTECTIOI•I AND LANDSCAPE PLANS PER THE .
Due Date 109/10/2010 Ii+.?I I CONDITIONS IN THE APPROVAL LETTER. I . 6,. Attachments
�_l •092. FINAL LANDSCAPE PLANS MUST HAVE WET-SIGN OF LANDSCAPE
Date Out j 09/14/2010 1 Time Out 24 1
.
12. FINAL
,
Status IN NOT APPROVED I I3 _ SHOW TREE PROTECTION FENCING AROUND ALL TREES THAT ARE
Status Date 1 9/14/2010 0.11 BEING PROTECTED. NO REMOVAL OF FENCING DURING
CONSTRUCTION_ PLEASE ADD THIS NOTE TO BUILDING PLANS FOR
Time Spent L 0.00 CONTRACTOR TO ACKNOWLEDGE THIS. •
F_-_:-_---
Contractor I r.' I 4. AN ARBORIST REPORT WILL BE REQUIRE PRIOR TO FINAL '
' _ -I — 11NSPECTIONS AFFIRMING THAT THE EXISTING TREES BEING USED
Sent To j FOR PRIVACY PROTECTION ARE ADEQUATE.
Sent By plug
S. A LANDSCAPE INSTALLATION REPORT MUST' BE PROVIDED PRIOR ,
TO FINAL INSPECTIONS.
6. PRIVACY PROTECTION COVENANTS MUST BE RECORDED PRIOR TO -
FINAL INSPECTIONS. '
1_7__A_LAIID-SCARE_P_ROTECTION—C_OVEN.k T_MU5T_HE—RECORDED PRIOR 'v,
1 4 i4,F• ..i
COMMUNITYPLUS V8 .1 PAGE NUMBER: 1
DATE: 04/01/2013 MODULE pinrvrpt :
TIME: 07 :37 : 58 PLAN REVIEW STOP REPORT
SELECTION CRITERIA:
PERMIT NUMBER: 10080189 - YIN CHAN TYPE: 1R3SFDW
PARCEL ID : 35704080 . 00
PARCEL ADDRS : 10483 MIRA VISTA AVE CUPERTINO, CA 95014
APPLY DATE : 08/26/10 ISSUE DATE : 11/05/10 C/O DATE : 11/04/11
REVIEW STOP: ASSESS -
REV NO: 1 STATUS: A DATE: CONT ID:
REVIEW SENT BY: SUEW DATE: 11/05/10 DUE: 09/10/10 TIME SPENT:
REV RECEIVD BY: DATE: 08/26/10 SENT TO: ASSESSOR
REVIEW NOTES:
08/26/2010 NEW TWO-STORY(3760SQ) ,GARAGE(579SQ) & LANDSCAPE
AREA(4517SQ)
REVIEW STOP: BLDG - BUILDING DEPARTMENT REVIEW
REV NO: 2 STATUS: A DATE: 10/27/10 CONT ID:
REVIEW SENT BY: roberts DATE: 10/27/10 DUE: 10/20/10 TIME SPENT: 0 .00
REV RECEIVD BY: LARRY DATE: 10/13/10 SENT TO:
REVIEW NOTES:
10/14/2010 2ND SUBMITTAL CONSTRUCT 2 STORY SFDWL 3 , 760 SQ FT
ATTACHED 580 SQ FT
REVIEW STOP: BLDG - BUILDING DEPARTMENT REVIEW
REV NO: 1 STATUS: N DATE: 09/14/10 CONT ID:
REVIEW SENT BY: ArnoldH DATE: 09/14/10 DUE: 09/10/10 TIME SPENT: 0 . 00
REV RECEIVD BY: ARNOLD DATE: 08/26/10 SENT TO:
REVIEW NOTES:
09/14/2010 A written response letter clearly addressing each item
is required. Re-submittal without a response letter
will be considered incomplete. Responses must fully
address the comment and indicate where items are
located. Any changes to the drawings or calculations
requires a delta-revision cloud bubble around the
changes, and a date stamp indicating when the changes
were made. For any questions regarding the Building
Comments, please call (408) 777-3235.
1 . Sheet A0, Sheet Index: Include the Cupertino
Construction Best Management Practices Sheet.
Response:
2 . Sheet A0 : Provide a Deferred Submittal List,
showing all deferred submittals (such as Fire
Sprinklers, Gas Piping Diagram, etc . ) . For buildings
over 3 , 600 sf, Fire sprinklers are required. Response:
3 . Designer to sign all sheets, and provide printed
name in the Consultant Directory on sheet A0. If an
architect, provide stamp and signature.
Response:
4 . Sheet A0, Site Plan: Show locations of all
easements. Show locations of any right of ways, to
COMMUNITYPLUS V8 . 1 PAGE NUMBER: 2
DATE: 04/01/2013 MODULE pinrvrpt:
PERMIT NUMBER: 10080189 - YIN CHAN TYPE: 1R3SFDW
PARCEL ADDRS : 10483 MIRA VISTA AVE CUPERTINO, CA 95014
enter property.
Response:
5 . Sheet A0, Site Plan: Demonstrate that the ground
floor of the building is built above the flood plain.
Response:
6 . Revise soils report. Provide boring samples, and
all info required per section 1802 . 6 of 2007 CBC.
Response:
7 . Per item 6, provide a letter of acceptance from the
soils engineer, accepting the foundation design of the
building.
Response:
8 . Sheet A2 and A3 : Provide written dimensions of the
second floor on sheet A3 . On key plans on A2,
demonstrate how the square footage was calculated for
each level. First floor seems to exceed 3 , 300 sf.
Unable to verify square footage of 2nd floor since no
dimensions were provided; as a result, a full plan
review could not be performed.
Response:
9 . Sheet A2 and A3 : Provide the following info
regarding stairs and changes in heights:
a. Provide details for the winder stairs,
demonstrating that they meet the requirements of
sections 1009 . 3 . 2 and 1009 .3 . 3 of 2007 CBC.
b. Provide notes on maximum stair riser and tread. Per
section 1009 . 3 of 2007 CBC, for R-3 and dwelling units
in R-2 occupancies (and any group U occupancies
accessory to the R occupancies stated) , the maximum
riser height can be 7 .75-inches. Minimum tread depth
can be 10-inches, but for any tread depth less than
11-inches, a nosing of not less than 0 .75-inches, but
not more than 1 .25-inches shall be provided. Also,
doors cannot swing over riser.
c . Provide details for handrails and guards, showing
their mounting heights above finished floor and nosing,
per section 1009 .10 and 1013 . Demonstrate method of
attaching guardrail posts, and that it is capable of
withstanding the required loads per section 1607 .7 . 1 of
2007 CBC.
d. Show locations of all thresholds and changes in
heights and landings. Show sizes of all landings,
especially at exterior and at the change in elevation
between Garage, Laundry Room, and Family Room.
Response:
10 . Sheets A2 and A3 : Demonstrate which Bedroom
windows meet the emergency egress requirements per
COMMUNITYPLUS V8 . 1 PAGE NUMBER: 3
DATE: 04/01/2013 MODULE pinrvrpt:
PERMIT NUMBER: 10080189 - YIN CHAN TYPE: 1R3SFDW
PARCEL ADDRS : 10483 MIRA VISTA AVE CUPERTINO, CA 95014
section 1026 of 2007 CBC. Per section 1026 of 2007
CBC, egress windows require minimum dimensions of: 5 .7
sf opening (grade floor allows 5 sf) , 24-inch high
opening, 20-inch wide opening, and opening to be
44-inches above finished floor.
Response:
11 . Sheet A2 : At the Garage, provide either a
20-minute rated door or a 1-3/8-inch thick self closing
self latching tight fitting solid core door, per
section 406 . 1 .4 of 2007 CBC.
Response:
12 . Sheet A2 : Indicate direction of slope and
percentage of slope in garage. Per section 406 .2 . 6 of
2007 CBC, garage is to be sloped to drains or to the
main vehicle entry way. Demonstrate if a drain occurs
(in garage or at the front of the garage) . Response:
13 . Sheet Al and A2 : Per section 1803 . 3 of 2007 CBC,
ground is to slope away from foundation 5% for a
distance of 10 feet away from the building; if 10-feet
cannot be met, provide swales . Provide 2% slope if
impervious surface is used.
Response:
14 . Sheet A2 : Identify ceiling heights at all areas
(especially at coffered ceilings) and demonstrate which
areas are vaulted ceilings .
Response:
15 . Sheet A2 and A3 : Provide tempered glass at
windows that enclose tubs and showers that are less
than 60-inches from the tub floor, per section 2406 . 3
of 2007 CBC.
Response:
16 . Sheet A2 : Provide tempered glass for the windows
adjacent to the steps/ walkways at the Living Room
(next to the front entry) , at the Family Room (next to
steps) and at the Breakfast Nook Bay Window (next to
steps) as they are in a hazardous location. Per
section 2406 .3 of 2007 CBC.
Response:
17 . Sheet A2 and A3 : Show locations and size of attic
access and crawl space access. Per section 1209 .2 of
2007 CBC. Attic access is required where the clear
ceiling height is more than 30-inches. If attic access
to 1st floor roof is achieved at the 2nd floor walls,
show locations at 2nd floor.
Response:
18 . Per item 17, if any attic access is located in
shearwalls of the 2nd floor, demonstrate via
calculations and details that load path and capacity of
shear wall is not affected.
Response:
COMMUNITYPLUS V8. 1 PAGE NUMBER: 4
DATE: 04/01/2013 MODULE pinrvrpt:
PERMIT NUMBER: 10080189 - YIN CHAN TYPE: 1R3SFDW
PARCEL ADDRS : 10483 MIRA VISTA AVE CUPERTINO, CA 95014
19 . Sheet A3 and A6 : Show locations of chimneys for
fire places, and show their clearance dimensions to the
exterior walls .
Response:
20 . Sheets A4a, A4b, and A6: Provide Class A Roofing,
per Cupertino Municipal Code section 16 . 04 . 080.
Response:
21 . Sheet A2 : Clarify if chimney is gas or wood
burning. Provide details on construction methods,
clearances to combustible construction, anchorage
details, hearth extension details, hearth support
(non-combustible construction) , fire box construction,
minimum duct/flue dimensions, and source of combustion
air. Show method of anchoring masonry veneer to
chimney. Indicate method of flue. See section 2111
for Masonry Fireplaces, and Spark Arrestors are
required. If a gas unit is used, provide listing
agency and listing number and model and make number of
chimney.
Response:
22 . Sheets A4a and A4b: Per section 802 . 5 .2 . 1 of 2007
CMC, chimney to terminate at least 3-feet above the
highest point where it pass through a roof, and at
least 2-feet higher than any portion of the building
within a horizontal distance of 10-feet. Response:
23 . Structural engineer to provide structural details
on method of connecting chimney back into house
framing, per items 21 and 22 . Provide seismic analysis
of chimney with masonry veneer.
Response:
24 . Provide details for the method of attaching stone/
slab veneer to the house, per sections 1405 . 6 and
1405 .7 of 2007 CBC.
Response:
25 . Sheet A5 : Sections and text are too small too
read. Provide clear dimensions .
a. Show framing at ceilings, to indicate which
sections have vaulted ceilings and which have flat
ceilings .
b. Indicate clear height in all attic spaces; ceiling
joists and roof rafters are not shown. See item 17 .
c . Show locations of attic insulation at the 1st floor
lower roof, to demonstrate building envelope
requirements per Energy Report (R-30 insulation) .
d. For any vaulted ceilings, coordinate item 26 below,
as each individual rafter space must have high and low
ventilation, per section 1203 of 2007 CBC.
COMMUNITYPLUS V8 . 1 PAGE NUMBER: 5
DATE: 04/01/2013 MODULE pinrvrpt :
PERMIT NUMBER: 10080189 - YIN CHAN TYPE: 1R3SFDW
PARCEL ADDRS : 10483 MIRA VISTA AVE CUPERTINO, CA 95014
Response:
26 . Provide attic ventilation calculations . Per 2007
CBC, section 1203, 50% of vents to occur at eave, and
50% of vents to occur 3-feet above eave line. Provide
size of vents, and number of vents . Show locations of
high vents on roof plan. Attic ventilation to be
distributed to each attic area (1st floor and 2nd floor
respectively) .
Response:
27 . Provide crawl space ventilation calculations. Per
2007 CBC, section 1203 . Provide size of vents and
number of vents.
Response:
28 . For all vents (such as gable, eave, and foundation
vents) , demonstrate that they do not interfere with any
brace walls/shear panels. Coordinate with structural
drawings. If vents are not to occur in
shearwalls/brace panels, indicate as such. If they do
occur in shearwalls/brace panels, demonstrate that
shear transfer is adequately addressed through details
and calculations . Provide notes and/or details (e.g.
edge nailing around openings, etc. ) .
Response:
29 . Sheet El, General Note 19 : Revise note to indicate
that all bedroom circuits shall be listed combination
type arc-fault circuit interrupters protected at the
panel . Circuits include luminary circuits, hard-wired
smoke detectors, and receptacle outlets . Rooms within
bedrooms (such as closets and open bathrooms/vanities)
shall also be included. Per section 210 .12 (B) of 2007
CEC.
Response:
30 . Sheet El: Provide a detail or note indicating that
the attic equipment shall have (1) an accessible
opening of not less than 22-inches by 30-inches or the
at least as large as the largest single component of
the unit, (2) the passageway to the unit is not more
than 20 feet away measured along the centerline of the
passageway (when the clear height is less than 6-feet) ,
(3) shall have solid flooring not less than 24-inches
wide, (4) a level working platform not less than
30-inches by 30-inches in front of the unit, (4) a
permanent 120V receptacle outlet near the equipment,
(5) a light fixture near the equipment with the switch
for the fixture located at the entrance to the
passageway, (6) have a clear height at the access
opening of at least 30-inches. Per sections 904 . 11 of
2007 CMC and 1209. 2 of 2007 CBC.
Response:
31 . Sheet El : Provide a gas piping diagram. Diagram to
show length of all gas pipes, materials used, gas pipe
COMMUNITYPLUS V8 . 1 PAGE NUMBER: 6
DATE: 04/01/2013 MODULE pinrvrpt :
PERMIT NUMBER: 10080189 - YIN CHAN TYPE: 1R3SFDW
PARCEL ADDRS : 10483 MIRA VISTA AVE CUPERTINO, CA 95014
diameters, Btu and CFH of each piece of equipment. If
this is to be a deferred submittal, have a Deferred
Submittal List on sheet A0, showing this to be a
deferred submittal .
Response:
32 . Sheets El and E2 : Show locations of all electrical
panels and subpanels. Show locations of all gas
meters . Provide horizontal distances and vertical
distances of gas meter to any opening in the building.
Response:
33 . Per item 30, indicate method of combustion air of
attic furnace.
Response:
34 . Sheets El and E2 : Show locations of A/C units .
Response:
35 . Sheets El and E2 : Provide fans at all bathrooms for
mechanical ventilation, per section 1203 .4 . 2 . 1 of 2007
CBC. It is not clear if fans are used, as symbols in
bathroom are not shown in Legend.
Response:
36 . Sheet El: Show exterior weather protected GFCI
outlet at the front and rear of the house, as required
per section 210. 52E of 2007 CEC.
Response:
37 . Sheet El : Per item 21, indicate if Fire place is
gas.
Response:
38 . Sheets El and E2 : Per section 410 . 4 (A) and (D) of
2007 CEC, demonstrate that all luminaires installed in
wet or damp locations shall be listed for such use by
an approved and recognized agency. Luminaires subject
to shower spray must be listed "Suited for Wet
Locations. " Luminaires not subject to shower spray can
be listed as either "Suited for Wet Locations" or
"Suited for Damp Locations. "
Response:
39 . Sheet El, Electrical Notes : Indicate that all
luminaries in closets shall be listed for such use, and
will follow all dimensional clearances per section
410 . 8 of 2007 CEC.
Response:
40 . Sheet A2 : Provide minimum 1/2-inch thick sheetrock
at all concealed spaces under stairs, per section
1009 . 5 . 3 of 2007 CBC.
Response:
41 . Sheet El : Show more GFCI outlets at kitchen
countertop. Per section 210. 52C of the 2007 CEC,
electrical outlets are required to be spaced such that
COMMUNITYPLUS V8 . 1 PAGE NUMBER: 7
DATE: 04/01/2013 MODULE pinrvrpt:
PERMIT NUMBER: 10080189 - YIN CHAN TYPE: 1R3SFDW
PARCEL ADDRS : 10483 MIRA VISTA AVE CUPERTINO, CA 95014
no section of wall is more that 24-inches from an
outlet.
Response:
42 . Sheet El : per item 41 above, if an island or
peninsula occurs in kitchen, provide a GFCI outlet, per
section 210 . 52C(2) and (3) of 2007 CEC. Also, outlet
cannot be spaced below counter if the counter extends
more than 6-inches beyond the counter base support and
cannot be more than 12-inches below the countertop, per
section 210 . 52C(5) of 2007 CEC.
Response:
43 . Sheets El and E2 : Per section 210 . 52 items a and
b, there are many areas that do not have sufficient
outlet spacing along walls. Areas include:
a. Hallway between front entry way (as hallways more
than 10-feet long require outlets) .
b. Breakfast Nook north wall:
c. Family Room South wall, along fire place
d. Den Bedroom, west wall
e. Living and Dining Room north walls
f . Family Room North wall, along stair wall
g. Office Bedroom North Wall
h. Bedroom 1 west wall
i . Bedroom 2 west and east walls
j . Master Bedroom north and both south walls .
Response:
44 . Sheets El and E2 : Smoke detectors are required to
be inside each bedroom, and just outside each bedroom
in the immediate vicinity of area the bedrooms, per
section 907 .2 . 10 . 1.2 of 2007 CBC. Show locations of
detectors.
Response:
45 . Sheets El and E2 : Fan and lights must have separate
switches per current Energy Code, section 150 (k) 7 (B) .
This includes fan/light combo, unless exception from
150 (k) 7 (B) is used (fan continuing for extended period
of time after light is switch off) . If it is used,
indicate as such, and it must be a listed product for
such use from a recognized approval/ listing agency.
Response:
46 . Sheet Sl : Provide a statement that the building has
been designed in accordance with the soils report .
COMMUNITYPLUS V8 . 1 PAGE NUMBER: 8
DATE: 04/01/2013 MODULE pinrvrpt:
PERMIT NUMBER: 10080189 - YIN CHAN TYPE: 1R3SFDW
PARCEL ADDRS : 10483 MIRA VISTA AVE CUPERTINO, CA 95014
Indicate soils report date, report number, soils
engineer, and contact information of soils engineer.
Response:
47 . Sheet Si: Provide the design criteria for the new
building:
a. Indicate the dead and live loads used for the
building (roof, exterior walls, exterior walls with
masonry, floor loads) .
b. Indicate the base shear (Cs value) used for the
design.
c. Indicate the soils bearing capacity (per soils
report) for dead and live loads, and increase for wind/
seismic.
Response:
48 . Sheet Si: Provide a Structural Observations List,
to be performed by the engineer of record. For
example, epoxy holdowns, rebar placement, shear
diaphragms, holdowns, general framing from Structural
Engineer. Footing and pad excavations by Soils
Engineer,
Response:
49 . Sheet S4: Indicate the full extent of Roof beam RB1
4x12 , and show it' s support at the North end toward
grid line 4 . Demonstrate locations of posts/ king
posts. Demonstrate how loads distribute to 2nd floor
below and to foundation. Clarify if this beam is
continuous or not.
Response:
50 . Sheet S4 and S3 : Provide method of connection of
hip beams to ridge beam.
Response:
51 . Sheet S3 : Show header beams at the exterior
walls.
Response:
52 . Sheet S2 : Provide grid lines .
Response:
53 . Sheet S2 : On grid line 2, there is a 6-foot long
shearwall marked as Type A, however the holdowns on
this wall takes cumulative load from shearwalls on Roof
Level and 2nd Floor Level . Revise holdown. Response:
54 . Sheet S3 : Provide method of support for Beam RB6
between lines C and D. Demonstrate locations of posts/
king posts . Demonstrate how loads distribute to
foundation. Also, see item 50 .
Response:
COMMUNITYPLUS V8. 1 PAGE NUMBER: 9
DATE: 04/01/2013 MODULE pinrvrpt :
PERMIT NUMBER: 10080189 - YIN CHAN TYPE: 1R3SFDW
PARCEL ADDRS : 10483 MIRA VISTA AVE CUPERTINO, CA 95014
55 . Sheet S3 : Provide method of support for hip beams
RB3 between lines A and B near line 1 . Demonstrate
locations of posts/ king posts . Demonstrate how loads
distribute to foundation. Also, see item 50 .
Response:
56 . Sheet S3 : Provide reference details on this plan
showing method of connecting the lower roof diaphragm
to the exterior wall of the 2nd floor. Detail 13/S5 is
called out once. Demonstrate the extent of plywood at
ceiling joists, per detail 13/S5. Clarify locations of
any vaulted ceiling areas, and areas of coffered
ceilings, per item 14 .
Response:
57 . Sheet S3 : Per item 56, the analysis of the
building does not provide a diaphragm analysis of the
Roof and 2nd Floor. Provide a diaphragm analysis . Per
section 12 . 14 .8. 5 and 12 . 12 . 3 of ASCE 7-05, building is
to act as a single cohesive unit. There are
discontinuities in the diaphragms, and some areas that
are unclear. For example:
a. Per item 56, demonstrate how 2nd floor diaphragm is
achieved, as Living Floor Space has plywood at another
level than Lower Roof Diaphragm. Demonstrate full
extent of ceiling plywood, per detail 13/S5 .
b. On sheet S4, on line B, demonstrate how
discontinuity in collector is addressed on line B, as
skylight opening occurs . Provide collectors.
c . On sheet S3, large opening is created by winder
stair. Provide blocking and strapping details/ notes
around hole in diaphragm. Indicate size and extent of
straps/ blocking.
d. On sheet S3, on lines A and C, bay windows create
discontinuity in double top plates. Demonstrate how
collectors are achieved.
e. On sheet S3, indicate size of Living Space Floor
Joists. Indicate size of ceiling joists . Indicate
locations of vaulted ceilings and coffered ceilings.
Response:
58 . Sheet S3 : Collectors are not addressed for many
of the Roof shearwalls landing on the 2nd floor
framing. Provide a diaphragm analysis, and show how
collectors are achieved. Demonstrate method of
transferring load from these shearwalls onto the 2nd
floor diaphragm, as there is a discontinuity.
a. If method is through Lower Roof diaphragm, the
Lower Roof Diaphragm has a different nailing pattern
than the 2nd floor Living Space. Demonstrate capacity
of diaphragm is not exceeded.
COMMUNITYPLUS V8. 1 PAGE NUMBER: 10
DATE: 04/01/2013 MODULE pinrvrpt :
PERMIT NUMBER: 10080189 - YIN CHAN TYPE: 1R3SFDW
PARCEL ADDRS : 10483 MIRA VISTA AVE CUPERTINO, CA 95014
b. Many of the collectors for the Roof shearwalls onto
the 2nd floor are not shown. Provide collectors . For
example, on lines A, B, B. 5, both lines 3, and line 4.
Collectors must address the Roof shearwalls onto the
2nd floor diaphragm. If some beams are edge nailed,
please indicate as such. Provide strap locations, and
any joists that are to align to achieve continuity.
c. Many of the collectors for the 2nd Floor shearwalls
connecting to the 2nd floor are not shown. Provide
collectors. For example, on lines 4, 2, line 3 from
each side of the stair, lines 2, and each side along
line C. Collectors must address how the 2nd floor
shearwalls connect to the 2nd floor diaphragm. If some
beams are edge nailed, please indicate as such. Provide
strap locations, and any joists that are to align to
achieve continuity.
59 . Sheet S4: Show collectors at the two interior
shearwalls running along the winder stair. Show
rafters that align with these shearwalls and any
straps .
08/03/2011 NEW TWO-STORY(3760SQ) ,GARAGE(579SQ) & LANDSCAPE
AREA(4517SQ)
REVIEW STOP: FIRE - FIRE DISTRICT REVIEW
REV NO: 2 STATUS: A DATE: CONT ID:
REVIEW SENT BY: DATE: 10/19/10 DUE: 10/20/10 TIME SPENT: 0 . 00
REV RECEIVD BY: DOUG DATE: 10/13/10 SENT TO:
REVIEW NOTES:
10/14/2010 2ND SUBMITTAL CONSTRUCT 2 STORY SFDWL 3, 760 SQ FT
ATTACHED 580 SQ FT
10/19/2010 REQUIREMENTS SATISFIED.
REVIEW STOP: FIRE - FIRE DISTRICT REVIEW
REV NO: 1 STATUS: N DATE: 09/02/10 CONT ID:
REVIEW SENT BY: suew DATE: 09/02/10 DUE: 09/10/10 TIME SPENT:
REV RECEIVD BY: DOUG DATE: 08/26/10 SENT TO:
REVIEW NOTES:
08/26/2010 NEW TWO-STORY(3760SQ) ,GARAGE(579SQ) & LANDSCAPE
AREA(4517SQ)
REVIEW STOP: PLANNING - PLANNING DEPARTMENT REVIEW
REV NO: 3 STATUS: A DATE: 11/04/10 CONT ID:
REVIEW SENT BY: DATE: 11/04/10 DUE: 11/11/10 TIME SPENT: 0 . 00
REV RECEIVD BY: PIU DATE: 11/04/10 SENT TO:
REVIEW NOTES: ***NONE***
COMMUNITYPLUS V8. 1 PAGE NUMBER: 11
DATE: 04/01/2013 MODULE pinrvrpt :
PERMIT NUMBER: 10080189 - YIN CHAN TYPE: 1R3SFDW
PARCEL ADDRS : 10483 MIRA VISTA AVE CUPERTINO, CA 95014
REVIEW STOP: PLANNING - PLANNING DEPARTMENT REVIEW
REV NO: 2 STATUS: N DATE: 10/21/10 CONT ID:
REVIEW SENT BY: piug DATE: 10/21/10 DUE: 10/20/10 TIME SPENT: 0 . 00
REV RECEIVD BY: PIU DATE: 10/13/10 SENT TO:
REVIEW NOTES:
10/14/2010 2ND SUBMITTAL CONSTRUCT 2 STORY SFDWL 3, 760 SQ FT
ATTACHED 580 SQ FT
11/02/2011 1. PLEASE HAVE LANDSCAPE ARCHITECT WET SIGN THE PLANS
2 . PLEASE SHOW TREE PROTECTION DETAILS AROUND PROTECTED
TREES.
3 . IF NOTE HAS BEEN ADDED TO PLANS RE: TREE PROTECTION
FENCE, PER COMMENTS FROM FIRST SUBMITTAL, PLEASE LET ME
KNOW WHERE THEY ARE.
REVIEW STOP: PLANNING - PLANNING DEPARTMENT REVIEW
REV NO: 1 STATUS: N DATE: 09/14/10 CONT ID:
REVIEW SENT BY: piug DATE: 09/14/10 DUE:09/10/10 TIME SPENT: 0 . 00
REV RECEIVD BY: PIU DATE: 08/26/10 SENT TO:
REVIEW NOTES:
08/26/2010 NEW TWO-STORY(3760SQ) ,GARAGE(579SQ) & LANDSCAPE
AREA(4517SQ) -YIN CHAN WAS TOLD THAT THE PLANNING APPEAL
PERIOD WAS NOT OVER TILL 9/7/10 AND IF THERE WERE
APPEALS HE COULD HOLD UP HIS PLANS IN BLDG AND POSSIBLY
LOSE PLAN CK FEES. HE SAID HE WAS WILLING TO TAKE THAT
CHANCE.
09/14/2010 1, UPDATE PRIVACY PROTECTION AND LANDSCAPE PLANS PER
THE CONDITIONS IN THE APPROVAL LETTER.
2 . FINAL LANDSCAPE PLANS MUST HAVE WET-SIGN OF
LANDSCAPE ARCHITECT.
3 . SHOW TREE PROTECTION FENCING AROUND ALL TREES THAT
ARE BEING PROTECTED. NO REMOVAL OF FENCING DURING
CONSTRUCTION. PLEASE ADD THIS NOTE TO BUILDING PLANS
FOR CONTRACTOR TO ACKNOWLEDGE THIS.
4 . AN ARBORIST REPORT WILL BE REQUIRE PRIOR TO FINAL
INSPECTIONS AFFIRMING THAT THE EXISTING TREES BEING
USED FOR PRIVACY PROTECTION ARE ADEQUATE.
5 . A LANDSCAPE INSTALLATION REPORT MUST BE PROVIDED
PRIOR TO FINAL INSPECTIONS .
6 . PRIVACY PROTECTION COVENANTS MUST BE RECORDED PRIOR
TO FINAL INSPECTIONS.
7 . A LANDSCAPE PROTECTION COVENANT MUST BE RECORDED
PRIOR TO FINAL INSPECTIONS AND OCCUPANCY.
REVIEW STOP: PUBWORKS - PUBLIC WORKS DEPARTMENT
REV NO: 2 STATUS: N DATE: CONT ID:
REVIEW SENT BY: DATE: 10/18/10 DUE: 10/20/10 TIME SPENT: 0 .00
REV RECEIVD BY: CHAD DATE: 10/13/10 SENT TO:
REVIEW NOTES:
10/14/2010 2ND SUBMITTAL CONSTRUCT 2 STORY SFDWL 3, 760 SQ FT
COMMUNITYPLUS V8. 1 PAGE NUMBER: 12
DATE: 04/01/2013 MODULE pinrvrpt:
PERMIT NUMBER: 10080189 - YIN CHAN TYPE: 1R3SFDW
PARCEL ADDRS : 10483 MIRA VISTA AVE CUPERTINO, CA 95014
ATTACHED 580 SQ FT
REVIEW STOP: PUBWORKS - PUBLIC WORKS DEPARTMENT
REV NO: 1 STATUS: N DATE: CONT ID:
REVIEW SENT BY: DATE: 09/09/10 DUE: 09/10/10 TIME SPENT: 0 .00
REV RECEIVD BY: CHAD DATE: 08/26/10 SENT TO:
REVIEW NOTES:
08/26/2010 NEW TWO-STORY(3760SQ) ,GARAGE(579SQ) & LANDSCAPE
AREA(4517SQ)
REVIEW STOP: SANITARY - SANITARY DISTRICT REVIEW
REV NO: 3 STATUS: P DATE: CONT ID:
REVIEW SENT BY: DATE: 11/03/10 DUE: 11/03/10 TIME SPENT: 0 .00
REV RECEIVD BY: NICHOL DATE: 11/03/10 SENT TO:
REVIEW NOTES: ***NONE***
REVIEW STOP: SANITARY - SANITARY DISTRICT REVIEW
REV NO: 2 STATUS: N DATE: CONT ID:
REVIEW SENT BY: DATE: 10/18/10 DUE: 10/20/10 TIME SPENT: 0 .00
REV RECEIVD BY: NICHOL DATE: 10/13/10 SENT TO:
REVIEW NOTES:
02/26/2013 2ND SUBMITTAL CONSTRUCT 2 STORY SFDWL 3, 760 SQ FT
ATTACHED 580 SQ FT
REVIEW STOP: SANITARY - SANITARY DISTRICT REVIEW
REV NO: 1 STATUS: N DATE: CONT ID:
REVIEW SENT BY: DATE: 09/08/10 DUE:09/10/10 TIME SPENT: 0 .00
REV RECEIVD BY: NICHOL DATE: 08/26/10 SENT TO:
REVIEW NOTES:
08/26/2010 NEW TWO-STORY(3760SQ) ,GARAGE(579SQ) & LANDSCAPE
AREA(4517SQ)