13040056 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 11776 PINEBROOK CT CONTRACTOR:MEANDAL ELECTRIC PERMIT NO:13040056 INC OWNER'S NAME: GUNASEELAN`LAKSHMINARAYANAN P O BOX 1410 DATE ISSUED:04/05/2013 OWNER'S PHONE: 4082558650 BRENTWOOD,CA 94513 PHONE NO:(925)240-2300 ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL 11S COMMERCIAL License Class �� Lica# INSTALL EVC STATION IN GARAGE 5.7 KW,30 AMP ,�`,: CIRCUIT Contractor O�►� �tr?r=Date I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)ofDivision:3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$1200 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:36604051.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and'county ordinances and state laws relating WIT 8 AYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 D OM LAST CALLED INSPECTION. indemnify and keep harmless the City.of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,the applicant understands and will comply Issued by: Date: 77 with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. RE-ROOFS: Signatur v Date All roofs shall be inspected prior to any roofing material being installed.If a roof is Wlow101 installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not:intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively.contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(x)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 370.0 of the Labor,Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this:permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505,1553a, d 25534. Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Owner or authorized age Date: I certify that in the performance of the Work-for which this permit is issued,I shall not employ any person in any manner so,as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application°and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date GENERAL PERMIT APPLICATION MEP COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION . 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 by (408)777-3228•FAX(408)777-3333•buildinq@.cupertino.orp misc CUPERTINO ❑PLUMBING ❑NWECHANICAL ®ELECTRICAL MISCELLANEOUS PROJECT ADDRESS 11776 PINE BROOKS EET_ APN# y� OWNERNAME LAKSHMINARAYANAN GUNASEELAN PHONE 408-255-8650 E-MAJL V STREET ADDRESS 11776 PINE BROOK STREET CITY,STATE,z>P CUPERTINO,CA.95014 FAx CONTACT NAME Mark Hammerschmidt PHONE 925.-240-2300, &M'IL info6meandalelectric.com STREET ADDRESS 752 Buckeye Court crrY,STATE,z1P Brentwood,CA 94513 FAX 925-240-2321 ❑OWNER ❑ OWNER-BUILDER ❑ OWNER AGENTIlY CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑TENANT CONTRACTOR NAME Meandal Electric Inc. LICENSE NUMBER 904775 LICENSETYPE C-10 BUS.LIC# 34304 COMPANY NAME Meandal Electric Inc. E-MAIL info@meandalelectric.com FAX 925-240-2321 STREETADDRESS 752 Buckeye Court crrY,STATE,z1P Brentwood,CA 94513 PHONE 925-240-2300 ARCHITECT/ENGINEER NAME NSA LICENSE NUMBER BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP - PHONE USE OF SFD 0,DUPLEX ❑ MULTI-FAMILY PROJECT IN W ILDLAND ❑ YES PROJECT IN. ❑YES IS THE BLDG AN ❑YES BUILDING: ❑COMMERCIAL URBAN INTERFACE AREA NO FLOOD ZONE PC NO EICHLER HOME? D(NO DESCRIPTION OF WORK - Install new 240V receptacle on dedicated 30A circuit from 125A main panel for 24A EVSE in garage. TOTAL VALUATIOX /2 60 � " y By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the ero owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. agree to comply with all applicable local ordinances and state laws relaf buildin Bs I. I authorize representatives of Cupertino to enter the above-' ntiffd property for inspection purposes. Signature of Applicant/Agent; Dat SUPPLEMENTAL INFORMATION REQUIRED 'IS7' k M MEPMiscApp_2011.doc revised 06121111 CITY OF CUPERTINO FEE ESTIMATOR—BUILDING DIVISION ADDRESS: 1 (Q el Ap SrU6(L DATE: 04/05/2013 REVIEWED BY: Mendez APN: I BP#: "VALUATION: 1$1,200 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration/ Repair PRIMARY SFD or Du lex PENTAMATION SOLAR-RFS USE: p PERMIT TYPE: WORK I install evc station.in garage, 20 amp circuit SCOPE ISM Meeh, Platz Check. Plumb.Plum Check Elec.Plan Check 0.0 hrs $0.00 -Iech.1'emtit Fee: Plumb.Permit l ee: Elec.Permit Fee: IEPERAVT F Heck Imp. Other Plumb Insp. ET--L_ Other Elec.Insp. 0.0 hrs.Insp.fee: Plumb. hasp.Fero: Elec. Fee: NOTE:This estimate does not include fees due to other Departments(Le.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc). These fees.are based on therelimina in ormation available and are onl an estimate. Contact the Det or addn'l info. FEE ITEMS (Fee Resolution 11-053 E . 7f� 11112) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 T-1 # Alternative Energy System Suppl.PC Fee: (j) Reg. .0 OT 0.0 m's $0.00 $102.00 ICHRGSTA EV Charging Station PME Plan Check: $0.00 F 30 amps Electrical Permit Fee: $0.00 $45.00 1 IBELEC200 Services Suppl.Insp.Fee-.0 Reg. OOT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: 7-1 $45.00 Construction .Tux: Administrative Fee: 1ADMIN $42.00 Work Without Permit? ®Yes 0 No $0.00 Advanced Planning Fee: $0.00 Select a Non-Residential Building or Structure Travel Documentation Fee: 1TRAVDOC $45.00 i Strong Motion Fee: 1BSEISMICR $0.50 Select an Administrative Item Blda Stds Commission Fee: IBCBSC $1.00 $133-501 $147.00111Mrr -MIN $280.50 Revised: 04/01/2013 COP4IMUNITY DEVELOPMENT DEPARTMENT BUILDING DIViSiON-CUPERTINO NIP �R0a,ED Th zlt of rplans and specifications p construction. It is unlawful to make any to 7 6 5 4 3 2 v� L NOT ation E Law. vi PROPOSED 24A EVSE ` &240V RECEPTACLE p (ON 30A DEDICATED p vim 125A CIRCUIT FROM 3-CAR 1IOWT MAIN 125A MAIN PANEL) GARAGE PANEL yam iV DAM DRIVEWAY � �� �`� a IH't 11776 PINE BROOK COURT, CUPERTINO, CA 95014 (SFR-2853) ATJ Pr 'ect a[ity rxaxrae r�cse=cis i PWPREM AND ccwwffvl. w<eR oo m A MEAne em ■INE MOW eF M I�Tam�N 1°7E (925) 240.2300 MAIN 430 S 2ND AVE. ev°NNNNI atlO!.lYe '"`@'°"°eT6ml"°" e PHOENIX AZ 83003 � ELECTRIC (925) 240-2321 FAx TEL 602-716-9576 CYLIl4 TWSOMIOI gYNmli ml NL Itiil6 II®e® NC NNl Y6 O °R — 8 1 7 1 a 1 5 1 4 Load Calculations for proposed EVSE circuit addition at: 11776 Pine Brook Court,Cupertino,CA 95014(SFR-2853) General liahtine and receptacle loads 220.83(A)(1) #of units VA Totals Area,sq.ft.*3VA Tbl 220.12 2334 VA (1)total VA Small appliance&laundry branch circuits 220.83(A)(2) #of units VA Totals Small appliances 220.52(A)(minimum 2)*1500VA 2VA Each addl.Small appliances '"; MVA VA Laundry 220.52(6) 1VA (2)total Cooking Equipment 220.83(A)(3) VA or kW VA Stove/Oven/Range total 8,800 (3)total VA All other appliances 220.83(A)(4) Dryer(gas only) °' VA Dishwasher 1 744 v�' M .VA Disposal 1 972 '""`'`' VA VA k E,\VA (4)total VA total general load VA First 8kw @100% 8,000 Remainder @ 40% 5,607 Sub-total calculated service load Heating or A/C 220.60 VA or kW Heating unit 1800 A/C unit 7776 largest load @ 100% total VA EV Charging Station 625.21 VA or kW 5,760 VA EVSE @ 125%(per 625.21)n additional 25% MVA Total Calculated Service Load per 220.83 VA Minimum Service Ampacity=Total Calculated Service Load/240V A Intelligent EV solutions bink • During performance of the work and after all requirements of this installation manual and associated details are fully completed, ECOtality NA and/or the customer shall have the option to inspect the work. • The installer or contractor shall not modify or otherwise alter blink equipment in any manner other than specifically authorized by this installation manual. Unauthorized modification to the blink equipment voids the manufacturer's warranty. Customer responsibility The customer is responsible for contracting with a certified electrical contractor to perform all electrical work, including connections at the blink, supply circuit, and main service panel. Tools required for installation Meters • Current Clamp Meter (with 600 A MAX AC/DC) (Recommend: Fluke 336) • Digital Multimeter (1000V MAX DC/AC) (Recommend: Fluke 87V) Hand tools • Drill bit, 3/16-inch • Hammer • Pencil/marker • Slotted and TORR®-head screwdrivers • Wrench, 10 mm • Torque wrench Installer-supplied items • Service wiring#o blink • Conduit.and fittings.(1-inch trade size), except for cord-connected units . . ..................................................................... .. blink features and specifications Features • Certified to UL 2594- Electric Vehicle Supply Equipment • Charge circuit interruption device (CCID20) • Ground monitoring circuit • Nuisance-tripping avoidance and auto re-closure ................................... ........ ........................................................... IM0001_L2_R_WM_USAv2.1 5 Intelligent EV solutions bink ............................................................................................................................................ • Cold load pickup (randomized auto-restart following power outage) • Certified energy and demand metering • Wireless IEEE 802.11 g • LAN capable • Web-based. bidirectional.data flow • Cord management system • Power cord for connection to NEMA 6-50R receptacle (WE-30C and WE-48C only) Specifications ModelE-48C�J� Input Voltage 208-240 VAC +/•10% (120 VAC to GND) Input Phase Single (3-wire) FrequCY en60 Hz AFRInput Current (maximum); ; configurable to 12A, 16A, , Breaker SizeAmps;40 Ava' ble settings: 48 Amps;;Agile-set#:Rgf,* 15A, 20A or 40A , OF.60A— Output Voltage 208-240 VAC +/•10% Output Phase Single Pilot SAE JI 772TM compliant Connector/Cable SAE J1772 compliant; UL-rated at 30A maximum Cord Length (output) 18 feet(approximate) Cord Length (input) 1 foot(WE-30C and WE-48C only) Exterior Dimensions Charger assembly: 18"wide x 22" high x 5-9/16" deep Cord reel: 18 diameter Temperature Rating •22 OF (•30°C) to+122 °F (+50°C) Enclosure NEMA type 3R sun-and heat-resistant Mounting Wall mount ...........................................................................................................................................: 6 IM0001_L2_R_WM_U5Av2.1 Intelligent EV solutions bink Charger assembly layout The charger assembly should be mounted on the wall in close proximity to the vehicle stall and at a location where the 18-foot charging cord can be easily connected to the vehicle charging port without the cord stretching taut and/or presenting a trip hazard. The charger assembly must be mounted at a height (minimum 18 inches [460 mm] above floor) where the panel display can be easily seen and monitored by the operator. A height of 60 inches (152 cm) to the center of the display is suggested. The cord reel can be mounted below or in another location near the charger assembly that best accommodates the user's preferences and comfort. The charger assembly and cord reel may be installed on adjacent walls (corner mounted). For cord- connected blinks(Models WE-30C and WE-48C), there must be sufficient space allowed between the charger assembly and mounting of the cord reel for installation of the 6-50R receptacle. lam, WARNING: RISK OF FIRE This equipment has arcing or sparking parts that must not be exposed to flammable vapors. This equipment must be located at least 18 inches (460 mm) above the floor. SUGGESTED- HEIGHTTt3 t?ISOLA1l t A�� apt TS (UPPER) i" j 0-5011 t J i RECEPTACLE 53-364"(REF) -»- - LAG BOLTS (UPPER) 36.314" (REF) MINIMUM CLEARANCE TO FLOOR is. Figure 1 -blink Installations,Typical IM0001_L2_R_WM_USAv2.1 7