Loading...
13020054 CITY OF CUPERTINO BUILDING PERMIT • BUILDING ADDRESS: 10496 S STELLING RD CONTRACTOR:SOLARCITY PERMIT NO:13020054 OWNER'S NAME: DANIEL YING 3055 CLEARVIEW WAY DATE ISSUED:02/15/2013 OWNER'S PHONE: 4086665863 SAN MATEO,CA 94402 PHONE NO:(650)638-1028 ❑ LICENSED CONTRACTOR-'SS DECLARATION JOB DESCRIPTION: RESIDENTIAL❑ COMMERCIAL License Class C h Lic.# qS /L7-1 INSTALL 10 ROOF-TOP FLUSH MOUNTED SOLAR (� PANELS Contractor L/l. 1 Date `��'!1l 1-� (2.45KW) I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$10000 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:35913127.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS 'ERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS F' 0 ' �' T CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, —m+ if, / costs,and expenses which may accrue against said City in consequence of the ��' granting of this permit Additionally,the applicant understands and will comply Issu + �/� Date: / with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. 1 RE-ROOFS: Signorine Signature ) Date All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of thework for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain:Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505,2553 -.T i d 25534. VIS-W Section 3700 of the Labor Code,for the erformance of the work for which thisP Owner or authorized agent: *4111g, Date: permit is issued. I certify that in the performance of the work for which this permit is issued,.I shall not employ:any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have readthis application and state that the above information is correct,I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City:of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date \ /`. ALTERNATIVE ENERGY PERMIT APPLICATION IP �O COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION �4T_roS� 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 A V (408)777-3228 •FAX(408) 777-3333 •building a{�cupertinc.orqal CUPERTINO PROJECT ADDRESS Jo //r/r6 3‘ \ l l Ad r APN3 5q .. ( 3 ( 2;9... OWNER NAME \ IL _ / ij-( ��y( �I PHOj�!$�i15!,a6 -� "Vo J . E mAN• •�]/J V1,D 7,_,9-61 ./ / ()0141 STREET ADDRESS ('(�Jj/ CITY,ST(c, f FA IM l gji C.tWzrhyle CONTACT NAME t w \ ~ PHONE E-MAIL 41, Ct/Yt t �,J D GI/1/L�c STREET ADDRESS /CITY,STATE, ZIP FAX ❑ OWNER 0 OWNER-BUILDER ❑,OWNER AGENT } CONTRACTOR 0 CONTRACTOR AGENT 0 ARCHITECT 0 ENGINEER 0 DEVELOPER 0 TENANT CONTRACTOR NAME/42))ate• az- 1,1 ko1 1'i����I LICENSE NUMBER e, / LICENSE TYPED`I /6 BUS.LI �s,i /y s. COtvEPANY NAME ',,:j Y I E- [L y `� AX 656-212--/Q Z( 1a�C � n m404/(0 �1�c� s6f es,,/fy ,p0 L STREET AD LE ! / J /L/Y lr l /✓�Vjr CITY I—P c '/, 9 / !O y SCJ yq 3-3 7 ARCHITECT/ENGINEER NAME LICENSE NUMBER /// BUS.LIC 14 COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF 'SFD or Duplex 0 Multi-Family PROJECT IN WILDLAND PROJECT IN '�ST,RRUCTURE: 0 Commercial j2URBAN INTERFACE AREA 0 Yes ❑ No FLOOD ZONE ❑ Yes ❑ No Q SOLAR PANELS 0 ELECTRIC VEHICLE CHARGING STATION 0 SOLAR WATER HEATING 0 OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UMTS: /V KILOWATTS( 4... V S TOTAL VALUATION/Q �7.V L a3 / /A/A / 1--27, //11 J 1�(/ DESCRIPTION OF WORK ' fQ y^�J)J L �L—v 7 J USA S/ — 711 7,I 1 I–el L / v!/ ,6 / p� /V �/,�l v � � i/ SO( pc 7zrs— Aw) _...„--: • ., FTBY� "-..". - .. ' 'r . : .-- f By my signature below,I certify to each of the following: am the pro.-rty.owner or authorized agent to.: . the pro.• o . alf I h. e read this application and the information I have.rovid'd is correct. have read e Description of i ork and verify it is accura e. I agree to comply with."applicable local ordinances and state laws relating to./ildi`,construction. authorize epresentatives of/ upertmo to enter the above-identified property for inspection purposes. /Signature of Applicant/Agent:: , / 1/01,1.41/01,1.4 % / I Date: 2.—/2 ��3 S "PLEMENTAL liRMATIONREQUIRED ? OFEICEUSEONLY .. a_ ❑' OVER THE-COUNTER • F ❑',EXPRESS• . .STANDARD . �' 1 LARGE At ❑.•MAJOR . PVApp_2011.doc revised 03/16/11 CITY OF CUPERTINO A FEE ESTIMATOR—BUILDING DIVISION OATADDRESS: 10496 S STELLING RD DATE: 02/12/2013 REVIEWED BY: MELISSA APN: 359 13 127 BP#: *VALUATION: I$10,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration/Repair PRIMARY SFD or Duplex PENTAMATION SOLAR-RES USE :p . PERMIT TYPE: WORK INSTALL 10 ROOF-TOP FLUSH MOUNTED SOLAR PANELS (2.45KW) SCOPE ^¢ ham` K 7« ile ca. Min Cheek .... .,a Plumb.Pkot Cheek /iFF...HZYi£d, I I 1,1rch Permit mit l e:: Plumb.Pei mit/ee: Dec. Permit t Pee: Other;1/Bei.. Irr,. >. Other Plumb lcsp. C.hlre> Lie( Insp. n ;,leca.1esr;./g r: Plumb.hasp Fee: /'Iec..lrts=. /='ee: NOTE:This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc.). These fees are based on the preliminary information available and are only an estimate. Contact the Dept for addn'1 info. FEE ITEMS(Fee Resolution 11-053 Eff 711/12) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 I 1 I # Alternative Energy System Suppl.PC Fee: Q Reg. ® OT 0.0 hrs $0.00 $219.00 IPHOTOVRES Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp.Fee:€ Reg. 0 OT 10.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 €.`o 3struc=tion Tay: ,Adm/ni:etrotiv°e Fee: Work Without Permit? 0 Yes eNo $0.00 0 Advanced Planning Fee: $0.00 Select a Non-Residential e Building or Structure 0 7'ravel Documentation Fees: Strong Motion Fee: 1BSEISMICR $1.00 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 $2.00 $219.00h.._ .�� M F $221.00 Revised: 01/01/2013 \\I\•N / Building Department City Of Cupertino 11V10300 Torre Avenue 40„11.9,4„ Cupertino,CA 95014-3255 Telephone: 408-777-3228 CUPERTINO Fax: 408-777-3333 CONTRACTOR/SUBCONTRACTOR LIST JOB ADDRESS: l O 4/(, 3, S , 3 ,, PERMIT#- d A'V OWNER'S NAME: Zvi PHONE# Ye ^W6--5 3 GENERAL CONTRACTOR: p -: 7 BUSINESS LICENSE# ,; ADDRESS: Z41/ -jj5�Po�-a CITY/ZIPCODE: � Peoy *Our municipal code requires all b sinesses working in the city to have a City of Cupertino busine license. / NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL. BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALLSUBCONT 5. CTO HAVE TAMED.:TAED A CITY; OF CUPERTINO BUSINESS LICENSE. e I am not using any subcontractors: ,,, i , - /Z—/3 ti ature Date Please check applicable subcontractors and complete the following information v/ SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets &Millwork Cement Finishing Electrical Excavation Fencing Flooring/Carpeting Linoleum/Wood Glass/Glazing Heating Insulation Landscaping Lathing Masonry Painting/Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock • Tile .444.i___ ,i i _,Wr „,,g. I , —45 Owner/contractor Signature Date i Cyt � • 11111 MM. 441-0421 Rk 11111 • INSTALLATION MANUAL UL 1703 VERSION CUPERTINO ,Building Department I ; x FEL' 1k2013 REVIEWED FOR CODE COMPLIANCE Reviewed By. „ /1!' ri Trinasolar TSM_UL 1703_IM_2011_RevA The power behind the panel ktik ' INSTALLATION MANUAL UL 1703 version 1. DISCLAIMER OF LIABILITY The installation,handling and use of Trina Solar Crystalline series modules are beyond company control.Accordingly, Trina Solar does not assume responsibility for loss,damage, injury or expense resulting from improper installation, handling,use or maintenance. • Trina Solar assumes no responsibility for any infringement of patents or other rights of third parties that may result from use of the module.No license is granted by implication or under any patent or patent rights. Specifications included in this manual are subject to change without prior notice. 2. SAFETY PRECAUTIONS •When designing the SPV system,please always take into consideration the variation of the voltage under different temperatures(please check the respective temp.coefficients of the modules,the Voc of the modules will be rise when the temperature drops); For example:with TSM-190DC01 modules(Max.System voltage is 600V)the maximum series modules configuration number should NEVER can exceed N=10(600V/56.22V=10.7),taking into consideration the possible variation of the voltage due to the lowest temperature in winter at specified location can reach-40C. •We require that every series SPV module string should be fused prior to be connected with other strings.For the maximum fuse rate,please refer to the detailed specification sheet.. • Solar photovoltaic(SPV)modules generate electricity when exposed to light.An array of many modules can cause lethal shocks and/or burn hazards.Only authorized and trained personnel should have access to the modules. • Use properly insulated tools and appropriate protective equipment to reduce risk of electric shock. • Do not stand or step on the module. • Do not damage or scratch the front or backside surfaces of the module. • Never use a module with broken glass or torn substrate.Broken modules cannot be repaired and contact with any module surface or frame can lead to electrical shock. • Do not disassemble the modules or remove any part of the module. • Protect plug contacts against soiling;do not make any plug connections using soiled plug contacts. • Do not install or handle modules when they are wet or during periods of high wind. • Do not short the positive and the negative of a single SPV module. • Do not disconnect under load. • Make sure connectors have no gap between insulators.A gap can cause fire hazard and/or danger of an electrical shock. , w • Make sure that the polarity of each module or a string is not reversed considering the rest of the modules or strings • Artificially concentrated sunlight should not be used on the SPV module. • Maximum system voltage must not exceed 600V DC. • Under normal conditions,a solar photovoltaic module is likely to produce more current and/or voltage than reported under standard test conditions.Accordingly,the value of Ix marked on this module should be multiplied by a factor of 125 when determining the conductor current ratings,fuse sizes and size of controls connected to the SPV output.Refer to Section 690-8 of the National Electric Code for an additional multiplying factor of 1.25 which maybe applicable. • Installation in Canada shall be in accordance with CSA C22.1,Safety Standard for Electrical Installations,Canadian Electrical Code Part 1. 3. UNPACKING AND STORAGE • Before installation,keep all modules and electrical contacts clean and dry. • If it is necessary to store modules temporarily,a dry,ventilated room should be used. •When unpacking,carry modules with both hands.Do not place modules on top of each other. 4. PRODUCT IDENTIFICATION We recommend that you take note of the serial number,each individual module has a unique serial number. It is permanently attached to the backsheet of the module on the product sticker. 5. ENVIRONMENTAL CONDITIONS AND SITE SELECTION 5.1 CLIMATE CONDITION L i ,3 ar " ' -ao°c to+40°C Install Trina Solar Crystalline series modules in the -40°C to+85T following conditions: ,`+R�) � -200cto+40°c Note Mechanical load bearing(include wind and snow ; beiow8sRH% loads) of the module is based on mounting methods. below 112.78Ibs/ft2(5400Pa) Trinasolar 2 rn„^ 11\1() IAI_ I Ai ION MANUAL 111 1 /0> ver,ion is _ �,:.ate ,:r.•- � _ _. Professional system installer must be responsible for mechanical load calculation according to system design. 5.2 SITE SELECTION • In most applications,Trina Solar SPV modules should be installed in a location where they will receive maximum sunlight throughout the year. • Modules should not be shaded at any time of the day because of buildings,trees,chimney,etc. • Do not install SPV modules in corrosive environment,such as corrosive salt areas within proximity of the ocean or sulfurous area,etc. . • Do not install SPV modules in a location where it would be immersed in water or continually exposed to water from a sprinkler or fountain,etc. • modules should be mounted over a fire resistant covering,with adequate ventilation between the module backsheet and the mounting surface.Clearance between the module frames and surface of the wall or roof is required to prevent wiring damage and to allow air to circulate behind the module.The required minimal stand- off height is 115mm.Any slope less than 5in/ft(127mm/305mm)is required to maintain a fire class rating. • Do not mount SPV module in such way that the drain holes of SPV module are intended to block up. 5.2 SITE SELECTION Trina Solar SPV modules connected in series should be installed at same orientation and angle.Different orientation or angle may cause loss of output power due to difference of amount of sunlight exposed to the module. Typically,the optimal tilting of SPV module is almost the same as the latitude of installation location. 6. MOUNTING INSTRUCTIONS 6.1 MOUNTING METHODS PV modules can be mounted to the substructure using the following methods: (1) Screw fitting:Using corrosion-proof screws (M8) in the existing installing holes in the module frame. The frame of each module has I 2 MI 4 mounting holes used to secure the modules 3 to supporting structure. • Module frame must be attached to aF mounting rail using M8 corrosion-proof Figurel.SPV module installed with Screw fitting method screws together with spring washers and flat i)Aluminum Frame 2)M8 Stainless screw washers in four symmetrical locations on the 3)Flat Stainless Washer 4)Spring Stainless Washer SPV module. 5)HEX Stainless Nutt • The modules have been evaluated by for mounting using the 4 provided mounting holes in the frame. • Applied torque should be 8 Newton-meters.Please find detailed mounting information in the below illustration: (2) Clamp fitting:Using suitable module clamps on the side of the module frame to mount the modules(including "portrait orientation"and landscape orientation") • Use a certain number of clamps to fix modules on the mounting rail. • Modules clamps should not come into contact with the front glass and must not deform the frame. • Be sure to avoid shadowing effects from the module clamps. • The module frame is not to be modified under any circumstances. • When choosing this type of clamp-mounting method, please be sure to use at least four clamps on each module,two clamps should be attached on the long sides of the module(for portrait orientation)and short sides of the module(for landscape orientation).Depending on local wind and snow loads,additional clamps may be required to ensure modules can bear the load. • Applied torque should be 8 Newton-meters.Please find detailed mounting information in the below illustration Fringe modules installation Middle modules installation I II { rozi Figure2.SPV module installed with clamp fitting method 3 Trinasolar 4„:itz � a - _ x INSTALLATION MANUAL UL 1703 version Note: • Clearance between modules frames and surface of the wall or roof is required to prevent wiring damage and to allow air to circulate behind the module.Recommended stand-off height is 115mm. • Do not mount SPV modules in such way that drain holes of modules are blocked. • We recommend to use the landscape and portrait orientation to install the module,Please note the diagram below when install: 1/20 Module Width t CI it, Mounting 1/5 Module Width f Area I 1, Mounting 1/5 Module Width Area 1/20 Module Width 1 Figure3.Mechanical dimensions when modules installed at!orientation with Clamp fitting method 1/8 Module Width t Mounting 1/4 Module Width Area is 1/4 Module WidthMounting Area 1/8 Module Width z • Figure4.Mechanical dimensions when modules installed in portrait orientation with clamp fitting method 6.2 GROUNDING • All module frames and mounting racks must be properly grounded in accordance with appropriate respective national electrical code. • Proper grounding is achieved by bonding the module frame(s) and all metallic structural members together continuously using a suitable grounding conductor.Grounding conductor or strap may be copper,copper alloy, or other material acceptable for use as an electrical conductor per respective National Electrical Codes.The grounding conductor must then make a connection to earth using a suitable earth ground electrode. • We recommend to use the following methods to ground properly: M1 1 2 , :°,;,.,�.k r-#r`£3 ..,,Fy..-zr:=..-- ,'.. 3 1)Wire bolt and slot 4 2)Mounting wash hex nut 3)Aluminum frame 5 4)6-12 AWG cable 5)HEX Nut Figures.Tyco grounding bolt#2058729-1 Trinasolar 4 tog N JTAI I_Al ION MANUAL U1. 1 70 ver,ion 1. • Tyco Grounding hardware is a package that includes the grounding bolt,mounting and grounding hex nut. • Make electrical contact by penetrating the anodized coating of the aluminum frame,by tightening the The mounting wash hex nut(come with the star washer)to the proper torque(25 in lb.) • Select grounding wire size:(6 to 12 AWG solid bare copper)and install underneath wire binding bolt. • Tighten wire binding bolt to proper torque(45 in Ib). • The Tyco grounding bolt is only UL listed for use with 6-12 AWG bare solid copper wire. 6.3 MODULE WIRING Each module has two standard 90°C sunlight resistant output cables each terminated with plug&play connectors.The wire type and gauge of the output cables are 600V rated PV Wire cable and are 12AWG in size. This cable is suitable for applications where wiring is exposed to the direct sunlight.We required that all wiring and electrical connections comply with the appropriate national electrical code. For field connections,use the minimum 12AWG copper wires insulated fora minimum of 90°C and Sunlight resistance with insulation designated as PV Wire. • The minimum and maximum outer diameters of the cable are 5 to 7mm2. 7. MAINTENANCE AND CARE • Under most weather conditions,normal rainfall is sufficient to keep the PV module glass surface clean.If dust or dirt build-up becomes excessive,clean the glass only with a soft cloth using mild detergent and water. • Do not clean the modules with cold water during the warmer hours of the day in order to avoid creating any thermal shock that may damage the module. • Be cautious when cleaning the back surface of the module to avoid penetrating the substrate material.Modules that are mounted flat(0°tilt angle)should be cleaned more often,as they will not"self clean"as effectively as modules mounted at a 15°tilt or greater. • At least once a year,it is recommended to check the torque of terminal screws and the general condition of wiring. Also,check that mounting hardware is properly torqued.Loose connections will result in damage for the array. • Modules that have been replaced must be of same type.Do not touch live parts of cables and connectors.Use appropriate safety equipment(insulated tools,insulating gloves,etc.)when handling modules. • Cover the front surface of modules by an opaque material when repairing.Modules when exposed to sunlight generate high voltage and are dangerous. Trina Solar SPV modules are equipped with bypass diodes in the junction box.This minimizes module heating and current losses. • Do not try to open the junction box to change the diodes even if it malfunctions. • In a system that uses a battery,blocking diodes are typically placed between the battery and the SPV module output to prevent battery discharge at night. WARNING:For any electrical maintenance,the PV system must first be shut down.Improper maintenance can cause lethal electric shock and/or burns. 5 li nasolar • Trinasolar The power behind the panel ASIA PACIFIC AUSTRALIA CHINA 7:•I; ,r,a..a'•.0m1 16+Mat rinarin'Icoli Headquarters tivdn y N.W Jnno No. Irina Road,Irina I'V',Amnia! A110ralia 1'irL New U•nct C.hanozhoo, 21301.China T 1+1 T oS( ,19RY18200R F 111 +(7;;01 E F +dr„10 0;176021 111 r trm L,unm E salnsnrrinnsolar,a)m EUROPE CHINA Roor,K-1704 1,'06, > •+ § �,�,,. rru In nwnn;:1Plar,), GERMANY Cyt` l a a RI11 331,Inrlh 1.noxi Road, rims; 011.1-(' A ,a � til)ngha 70001(1 • - ..'s yP' s T T I I San;I)' ,n T 136.11 60'.1 S31(l At. F 1062160.7;333 F rt) n1)>ri,ln %1 11111. E >ales(,atrinasnla-r on) E p,rnunvn,drin.nnl.u.<.nln CHINA ITALY ._:` Via Sanl,l Mal in X_. V,lII'' l Oncl:;al`:=.`4,,:o:Cx:^.;a�li1P+.• .70123 Milan r40.40 Don q,!h+rnenwa i 0.0•000. Don!ch„ hal) 7 nn Di�•Ult.t, Reijinq 1000;7, T -43''I(1,`0068 I';JI T X86 10;!;17.10:;0 F I''.4,is 01(1, 140(1 F +46 10 s(74nm E iudya,,,lina..<,I,11,:1,111 E sab.r_c hin,llmhlnasnlat.cor., SPAIN KOREA ('as0o d:•1.1 c.s0,nana 141, 04,nnnt, Trina Solar Korea Ltd. 280.16 Madnd, R.-4,12,Intellirre 2. Spam 2d Inonaia-donq, Irondann-riti.Senngn:un-s+. T r3.1`•1':77167, r;y,eonD9rdo.'(01-841 F .....1911,7264,71 • Koren E spame,nrinaudm.r on) T 002 31 702 1580 - F 08211:100020 E koreax,hinasolacron, SWITZERLAND European FIG Trina Solar(Schweiz)AG JAPAN 1.•0101 honhar 1.04 Trina Solar Japan Ltd .:4,.n Cm u.h. World Tradc(rn)0!0,111114n4 awn;rgland .331h flout,;:.1;-rhmmn T .I4I 4 i „ln,aIII) I lainmmatsil-rho Minato-kll. F .11 08 In Tokyo 10'.61 i i E „ntop••;.ai u:anlal.<om Japan T +SI 1 tail-"000 F 401 3 343;7001 - E janann0uin,nnlar.a,n, NORTH AMERICA U.S.A. • Trina Solar(U.S.),Inc. 100 C..110 myt,r•Ill,•r,\Ilan 34(1, ..n Inset.A N',A T ,-1800696?II') F 1::40+,960166 F, uaafnl linaslLu,11141 www.trinasolar.com ABBREVIATIONS ELECTRICAL NOTES INDEX LICENSE JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING PV1 COVER SHEET CA # 888104 MEANS MAY BE ENERGIZED IN THE OPEN PV2 SITE PLAN C-46, C-10 AC ALTERNATING CURRENT POSITION, A SIGN WILL BE PROVIDED WARNING PV3 STRUCTURAL VIEWS BLDG BUILDING OF THE HAZARDS PER ART. 690.17. PV4 UPLIFT CALCULATIONS CONC CONCRETE C COMBINER BOX 2. EACH UNGROUNDED CONDUCTOR OF THE PV5 THREE LINE DIAGRAM' D DISTRIBUTION PANEL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PV6 ELECTRICAL CALCULATIONS PLOT PLANS BY PHASE AND SYSTEM PER ART. 210.5. Cutsheets Attached CHECKED BY DC DIRECT CURRENT 3. A NATIONALLY-RECOGNIZED TESTING EGC EQUIPMENT GROUNDING CONDUCTOR 2- --/ 2 -1 3 (E) EXISTING LABORATORY SHALL LIST ALL EQUIPMENT IN DATE EMT ELECTRICAL METALLIC TUBING COMPLIANCE WITH ART. 110.3. _ �— G SOLAR GUARD METER 4. CIRCUITS OVER 250V TO GROUND SHALL - "�- � PLANNING EPT. GALV GALVANIZED COMPLY WITH ART. 250.97, 250.92(B) CUTSHEETS ATTACHED GEC GROUNDING ELECTRODE CONDUCTOR 5. DC CONDUCTORS EITHER DO NOT ENTER GND GROUND BUILDING OR ARE RUN IN METALLIC RACEWAYS GENERAL NOTES DATE HDG HOT DIPPED GALVANIZED OR ENCLOSURES TO THE FIRST ACCESSIBLE DC I CURRENT DISCONNECTING MEANS PER ART. 690.31(E). FILDG. DEPT. Imp CURRENT AT MAX POWER 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN 1. THIS SYSTEM IS GRID-INTERTIED VIA A INVS INVERTERS RELIEF AT ALL ENTRY INTO BOXES AS UL-LISTED POWER-CONDITIONING INVERTER. SUBMI Isc SHORT CIRCUIT CURRENT REQUIRED BY UL LISTING. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. TTAL kVA KILOVOLT AMPERE 7. MODULE FRAMES SHALL BE GROUNDED AT THE 3. ALL INVERTERS AND ARRAYS ARE NEGATIVELY kW KILOWATT UL-LISTED LOCATION PROVIDED BY THE GROUNDED. SIL 1 LBW LOAD BEARING WALL MANUFACTURER USING UL LISTED GROUNDING 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED 777T' MIN MINIMUM HARDWARE. 5. ALL WORK TO BE DONE TO 2010 CALIFORNIA MIR MIRROR 8. ALL EXPOSED METAL PARTS (MODULE FRAMES, BUILDING CODE. 1 CUPERTINO 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE (N) NEW RAIL, BOXES, ETC.) SHALL BE GROUNDED USING so Building Department NEC NATIONAL ELECTRIC CODE UL LISTED LAY-IN LUGS LISTED FOR THE 2008 NATIONAL ELECTRIC CODE AS AMENDED BY I THE 2010 CALIFORNIA ELECTRIC CODE. I'~' � i NIC NOT IN CONTRACT PURPOSE. POSTS SHALL BE MADE ( f Fera 1 `E 2013 INSTALLING 10 ROOF-TOP FLUSH-MOUNTED NTS NOT TO SCALE ELECTRICALLY CONTINUOUS WITH ATTACHED• - OC ON CENTER RAIL. PANELS (2.45KW). O p PANEL BOARD 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE R 'JIE'V WED FOR CODE COMPLIANCE PL PROPERTY LINES BONDED WITH EQUIPMENT GROUND CONDUCTORS Reviewed By: ,__59,-,/ lyffj- CE/vEi D PV PHOTOVOLTAIC AND GROUNDED AT THE MAIN ELECTRIC PANEL. PVC POLYVINYL CHLORIDE 10. THE DC GROUNDING ELECTRODE CONDUCTOR VICINITY MAP FEB 12 2013 1 S SUBPANEL SHALL BE SIZED ACCORDING TO ART. SCH SCHEDULE 250.166(B) & 690.47. - F1p. ` ''"' '" _' ` - ;Football t; . Mod fl 0'G G) .r4 4, 14 ry F . M �" .---....—.....,,_ IN) SS STAINLESS STEEL _ _ w.. ''" SSD SEE STRUCTURAL DRAWINGS Potence ' g rn Y - '. ' s r ,, certRtf 1 it Feld :-tccer.Field is . sae s g c� c, ,.STC STANDARD TESTING CONDI11ONS ,��,', �. _-' ~' er a� �7.4"1410,:.,,,ii 3 ` SOLAR WATER HEATER ; , i ,r Arm c "` �. ..3 _�. 'SWH P _, 0',• Foctr R;ingr�, . No "� SHOmTYP TYPICAL '•. 7 0. w@ * C3 " Feel a SFr�I a' fir{ !r wl via `ti i t ,c7i, '<. V.-4,c UON UNLESS OTHERWISE NOTED .� child. . + t 'd' �. . ` UPS UNINTERRUPTIBLE POWER SUPPLY �1 , ., p^" ^ ` Iiw`, v 14 .1414, gDe �F.rr ent b', i a rw, i TVOLT CPRter , ad..1' s Y-P+,1�V 1 N r -�' -'L.. ; ; . `0 ,. ,�.ct.ryt Dr:. VmpVOLTAGE AT MAX POWER 1 4�=,. . . K"S`-►' �F`. it _ , Vo VOLTAGE AT OPEN CIRCUIT *r ''• `� a C / I t }~x„ w�.�.�i �. W WATT -4i- rw<cClelta` - '= Ch: '�� ` �` 3R NEMA 3R, RAINTIGHT � is + + � 3 , McCl�ell } •lel�an; o ro+ r r NiiPflf�E31 cp. 9 -1 . - i 1 , ''t r K - I w G] r I I. I.. " •I m ' `" • a t O . REV BY DATE COMMENTS N _ = V..' z * " '4 . •1 -;.:'-'4' .arc .," ' , vi . L. r' I . --_ k ��..` 1 _. rrs _ _ d r cif ��'_ ,+� j to ,mm .ar<v +•, . *, nr:i.:.1,6_,,, " -._ - -Kinvviin Ln1 r Nr .. -411 rl_—_ CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER J B-9501320 00PREMISE OWNER: AHd DESCRIPTICN: DESIGN: `��I f' CONTAINED SHALL NOT BE USED FOR THE YING, DANIEL YING RESIDENCE EOBAN �: BENEFIT LL ITANYONE EXCEPT SOLARCITYW-10LEINC., MARKET: MODULES: '//�SolarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN REST TRINA SOLAR ; TSM-245PC05 PA05.18• 10496 S STEELING RD 2.45 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS CUPERTINO, CA 95014 �� ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: MOUNTING SYSTEM: Way THE SALE AND USE OF THE RESPECTIVE S+P ST r 3055 Mateo, A 9440 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: San CA 94402 PERMISSION OF SOLARCITY INC. PAYMENT TYPE: INVERTER: T:(650)638-1028 F:(650)638-1029 PPA SMA # SUNNY BOY 3000-US (408) 666-5863 COVER SHEET PV 1 2/7/2013 (888)-SOL-CITY(765-2489)www.solarcity.corn PITCH: 23 ARRAY PITCH:23 MP1 AZIMUTH: 178 ARRAY AZIMUTH: 178 B MATERIAL: Low Profile W-Tile STORY: Two Stories ii I v 3 10496 S Stelling Rd I a 25'to PL I 000 • J CO D Front Of House 'tF� CUPERTINO I ; Building Department 40 1 / - ek,fidLiJ FF3142013 REVIEWED FOR CODE COMPLIANCE 7 © Reviewed By: <�,., ,`7� LEGEND M (E) UTILITY METER & WARNING LABEL 41) 30'to PL CO INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS DC DC DISCONNECT Sc WARNING LABELS • AC F:—I AC DISCONNECT & WARNING LABELS c 0 JUNCTION BOX TOTAL ARRAY AREA: 199.77 SQFT ® DC COMBINER BOX & WARNING 25'to PL TOTAL MOUNTING 0 DISTRIBUTION PANEL & WARNING PLANE AREA: Lc LOAD CENTER & WARNING LABELS 484.54 SQFT 1 B O DEDICATED PV SYSTEM METER ti' MP!. PV3 CONDUIT RUN ON EXTERIOR • M •41,' --- CONDUIT RUN ON INTERIOR GATE/FENCE o� / A ——— INTERIOR EQUIPMENT on 25'to PL PV3 SITE PLAN N m Scale: 1/8" = 1' W a' E n 10 1' 8' 16' N' m CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: JB-9501320 00 PREMISE OWNER AHJ DESCRIPTION: DESIGN: `%lag' CONTAINED SHALL NOT BE USED FOR THE YING, DANIEL YING RESIDENCE EOBAN �; , BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES n NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI TRINA SOLAR # TSM-245PC05/PA05.18 10496 S STEELING RD 2.45 KW PV Array � ��, SQ'(� y PART TO OTHERS OUTSIDE THE RECIPIENTS PROJECT MANAGER: MOUNTING SYSTEM: CUPERTI NO, CA 95014 / 14, 3055 Clearview way ORGANIZATION, EXCEPT IN CONNECTION WdTH THE SALE AND USE OF THE RESPECTIVE S+P ST San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: INVERTER PAGE NAME SHEET: REV: DATE: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. PPA SMA # SUNNY BOY 3000—US (408) 666-5863 SITE PLAN PV 2 2/7/2013 (888)-SOL-CITY(765-2489)www.solarcity.com (E) 2x4 TOP CHORD / 6' / 24" O.C. \ I I I I \ ® .... ...ti. (E) 2x4 II I • / 2' / (E) 2x4 TOP CHORDS /I'-5' i 5-7" / 4'-8" / 3'-2"---/ 24" r (E) LBW @ SPACING TOP CHORD: 2x4 SUPPORT: 2x4, WEB -- FRONT VIEW OF MP1 B MAX SPAN: 5'-7" SCALE: 1/2" = 1' TC GRADE: 2 i SIDE VIEW OF MP1 A SCALE: 1/4" = 1' CUPERTINO � , 1 Building Department INSTALLATION ORDER � -- ,€ F: 1 if 2013 ZEP SPANNER BAR LOCATE RAFTER, MARK RAFTER �r' 'fi=tn/En -��r CODE (6) LOCATION, AND REMOVE TILE. COMPLIANCE (1) PLACE STANDOFF BASE & DRILL -- ,/ MI'� S PILOT HOLES AT THE RAFTER Reviewed By: ,_:.-7 ,,,' �7� ME_ LOCATION. - dliri.NOM '.1 I lIlSw� CLEAN PAPER AROUND PILOT �1 (1) (2) !_______•••••!....w__ (7) (3) 2/ 2) HOLE. ZEP SPANNER �� _��_ �� ��, BAR CLAMP I 7� I ;, _ �',- ; ADJUST STANDOFF TO BATTEN AMP- �� ` = L�= 3) HEIGHT. STANDOFF _ (E) TILE SEAL PILOT HOLES AND BOTTOM li (4) OF STANDOFF WITH POLYURETHANE (E) ROOF DECKING (5) (4) SEALANT. 5/16" DIA LAG BOLT 0 LAG STANDOFF INTO RAFTER. (2-1/2" EMBED, MIN) LOWEST MODULE SUBSEQUENT MODULES (E) RAFTER 6) NOTCH TILE WEATHERING TO FIT STANDOFF AROUND STANDOFF. J Scale: 1 1/2" = 1' REINSTALL TILE. • CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-9501320 00 PREMISE OWNER AHL: DESCRIPTION: DESIGN: '`4044 CONTAINED SHALL NOT BE USED FOR THE YING, DANIEL YING RESIDENCE EOBAN �; ,, BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 10496 S STELLING RD 2.45 KW PV Arra �� REST TRINA SOLAR # TSM-245PC05/PA05.18 CUPERTINO CA 95014 y Ola ' Y PART TO OTHERS OUTSIDE THE RECIPIENTS PROJECT MANAGER: �� ORGANIZATION, EXCEPT IN CONNECTION WITH MOUNTING SYSTEM: > 3055 Clearvew Way THE SALE AND USE OF THE RESPECTIVE S+P ST San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE INVERTER PAGE NAME: SHEET: REV: DATE: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. PPA SMA # SUNNY BOY 3000-US (408) 666-5863 STRUCTURAL VIEWS PV 3 2/7/2013 , (888)-501-CITY(765-2489)www.solarcity.com UPLIFT CALCULATIONS 2/7/2013 SolarCity SleekMountTM Version#4.1 Project Information System&MP Information Symbol Value I Related Info Occupancy:Category II P.'System Type SolarCity Sleek-Mount— PV Module Trina Solar TSM-245PC Total(lumber of Modules 10 Roofing Material Spanish Tile Roof number of Layers(Comp Roofs Only) NA Tile Reveal(Tile Roofs Only) 4" Roof Slope 23° Spanning Vents? No Pe Module Orientation Landscape PV Module Length 3.3 ft PS'Module Width 5.4 ft Attachment Type S+P ST Total Square Feet of Array 176 sf Wind Design Criteria Wind Design Code ASCE 7-05 Partially/Fully Enclosed Method Exposure Category B Section 6.5.6.3 Basic Wind Speed V 85 mph Fig.6-1/Local Data Least Horizontal Dimension of Building LHD Roof Style Gable Roof Fig.6-118/C/D-14A'B Mean Roof Height h Section 6.2 Wind zone Interior Edge Corner Wind Pressure Up(psf; p(up; -10.0 -17.4 -27.0 Wind Pressure Down(psf) p(down) 10.0 10.0 10.0 Snow Design Criteria !Coefficients Ground Snow Load I pg I 1 I Table 7-1/Local Data Tile Allowable Attachment Spacing(inches)and Tributary Area(sf) i : k 'x CUP E RT I N O Interior Edge I Corner Tile Reveal(ins) f '6,;.",‘, Building Department Maximum Allowed Foot Spacing Landscape 72" 72" 72" 16" rw! • c,.., Maximum Allowed Cantilever Landscape 24" 24" 24" I.:'* -1 Max Standoff Tributary Area TribCL 8 sf 8 sf 8 sf `r (I F E J 1 It 2013 P/Assembly Dead Load WPV 3 psf 3 psf 3 psf -- OLPV PCL 24 lbs 24 lbs 24 lbs i-,L`:; \'ED FOR CODE COMPLIANCE WWI'-0.6 DLPV TCL -66 lbs -124 lbs -202 lbs Attachment Uplift Capacity Tallow 3513 lbs 350 lbs 350 lbs Reviewed By: �.9N /7/47--r-e/ TCL/Tallow DCRLand 18.7% 35.6% 57.6 �- CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: J 3_9501 320 00 PREMISE OWNER: AHJ DESCRIPTION: DESIGN: `%6141 CONTAINED SHALL NOT BE USED FOR THE YING, DANIEL YING RESIDENCE EOBAN a.. - . BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: ?�"7 'I1,So la rC ity NOR SHALL IT BE DISCLOSED IN ECOLE OR IN REST TRINA SOLAR TSM-245PC05/PA05.18 10496 S STEELING RD 2.45 KW PV Array ` � � PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: MOUNTING SYSTEM: C U P E R TI N O, CA 95014 THE SALE AND USE OF THE RESPECTIVE S+P ST 3055 Clea vew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: San Mateo,CA 94402 PERMISSION OF SOLARCITY INC. PAYMENT PPA INVERTER: # SUNNY BOY 3000-US (408) 666-5863 UPLIFT CALCULATIONS PV 4 2/7/2013 (888)-SOL-CCITY GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD (E) 200A MAIN SERVICE PANEL Inv 1: DC Negatively Grounded INV 1 —(1)SNA#SUNNY BOY 3000-US LABEL A —(10)1R 2urwsr z sB4swcps A F CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP (E) 200/2P MAIN CIRCUIT BREAKER Inverter:3000w,zoo/zaBv,B5.5z/Bsz C-46, C-10 Voc: 37.3 - Panel Number.SC2040M200C INV 2 Vpmax:30.7 Meter Number:1005900686 *MODULE CURRENT RATINGS ARE SHOWN AS Isc AND Imp IN Underground Service Entrance INV 3 THE DC STRINGS IDENTIFIER OF THE SINGLE LINE DIAGRAM. MAIN SERVICE PANEL Inverter 1 200A/2P Q2 SMA •� (E) LOADS SUNNY BOY 3000-US • 11 L1 I 240v 1 \ • GFP/GFCI (.0: \ N120A/2P EGC/ _ _DC+ Q DC+—/ /T\.A �- GEC O L�' DC_ � DC- CO Strings)Of 10 On MP 1 1\ B • • I L GND I-___EGC EGC V N — EGC/GEC � 0' z–z C' GEC -, TO 120/240V SINGLE PHASE UTILITY SERVICEI I I II ' t _;; _.` CUPERTINCJ I Building Department — 11:11.':1117,,,,,,--4!"::il FEB 1 4 2013 REVIEWED FOR CODE COMPLIANCE • Reviewed By: ,.5-4.. / POI (1)SQUARE 2 PV BACKFEED BREAKER Spoofs AC DC _(1)Ground Rod;5/B'a 8%,Copper 2 —(1)AWG/ID,TNBN-2,Black —(2)ABC r0,USE-2/RNW-2,Block Voc =373 VDC 1st =8.47 ADC O cn—(1)ABS RID,1HMM-2 Red (-1--. —(I)AWG p0.Surd Bus Copper ECC Vmp =307 VDC Imp=7.98 ADC (1)ABS#10,1HYM-2,Mite NEUTRAL Vmp =240 VAC Imp=12.5 MC (1)Conduit Kitt 3/4'EAT —(1)ABS(B,T1111N-2,Green EGC/GEC —(1)Conduit KN; 3/4'DAT CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER J B-9501 320 00 PREMISE OWNER: AH,L DESCRIPTION: DESIGN: `%►/4' CONTAINED SHALL NOT BE USED FOR THE YING, DANIEL YING RESIDENCE EOBAN .._ BENEFIT OF ITANYONE EXCEPT SOLARCITYLE INC., MARKET: MODULES: A.'If�SolareCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN REST TRINA SOLAR # TSM-245PC05/PA05.18 10496 S STELLING RD 2.45 KW PV Array lt41-- - PART TO OTHERS OUTSIDE THE RECIPIENTS PROJECT MANAGER: MOUNTING SYSTEM: ORGANIZATION, EXCEPT IN CONNECTION WITH CUPERTINO, CA 95014 THE SALE AND USE OF THE RESPECTIVE S+P ST 3055 Clea vow Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PACE NAME: SHEET: REV: DATE San Mateo,CA 94402 638-102 F: 638-1029 TYPE: ) (650) PERMISSION OF SOLARCITY INC. PAYMENT PPA INVERTER: (408) 666-5863 THREE LINE DIAGRAM PV 5 2/7/2013 (888)-5(OL-OCITY(7652489)Swww.solarrcty.com SMA # SUNNY BOY 3000—US 1.conductor Sizing per Art .8(6)(1) a. mustdegELECTRICAL CALCULATIONS Conductor have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). Module: 10 Trina TSM-245PC05.18 Black ZEP 222.9 Inv Pwr W PTC StrLen Voltage Drop Calculations Version 5_9.6 b. Conductor must have (after corrections for conditions of use) >= Inverter 1: 1 SMA SB-3000US(240V) 95.5% 3,000 2,129 10 Vdrop= (Imp) * (2'Length)*(Resistance) / (Vmp) continuous current per Table 310.15(6)(16). Module: . Imp(A) Max.Length(ft) Wire Inverter 2: String: 7.98 100 C AWG 10 at Max Ave Hi• 85 deg F Module: ' Vdrop= (7.98 A • 200 ft '0.00124 Ohms) / 279 V= 0.71% C. Evaluate conductor temperature at terminations per 110.14(C). Inverter 3: Branch: 7.98 I 0 I C AWG 10 at Max Ave Hi: 85 deg F • Ampacity of wire derated for conditions of termination must be >= Module: Vdrop= (7.98 A • 0 ft *0.00124 Ohms) / 279 V= 0.00% continuous current*1.25. All stringterminations are rated at 90' C. Inverter 4- Total voltage drop in DC conductors=I 0.71%1 Inverter: I 12.50 I 20 I C AWG 10_I at 240V Total 10 modules Total Inv Pwr 3,000 2,129 PTC Vdrop= (12.50 A ' 40 ft '0.00120 Ohms) / 240 V 0.25% 2. OCP Sizing per Art 690.8(B)(1) Photovoltaic Module Electrical Specifications: Total STC' 2,450 Combined) 12.50 1 0 I E AWG 06 I at 240V Voc= 37.3 V deg F deg C Vdrop= (12.50 A * 0 ft *0.00049 Ohms) / 240 V 0.00% a. Round up to next size per Art 240.4(6) Vmp= 30.7 V Record Low Temp: 16'-8.88888889 Total voltage drop in AC conductors= 0.25% lsc= 8.47 A Max Average Hi Temp: 85'29.44444444 Total voltage drop in AC and DC conductors= 0.96% Imp= 7.98 A ' 3. Conductor Sizing per Art 690.8(B)(1) , C a. Conductor must have 30 deg. C ampacity >= 125% of continuous lTisc= -0 11936 VA/d/deg g __ 9 P y Tisc= 3.981 mA/deg C I current per Art 215.2(A)(1). String Type A and 2 Combined Strings Type A Voc Correction Method: ManufTvoc data Branch Circuit Type A 1-way wire length: 0 ft $MA SB-3000US(240V) 1 strings per branch 1 ' 10'Irina TSM-245PC05.18 Black ZEP Inverter Min Vdc Input: 200 Vdc 10 modules per series string ' b. Conductor must have (after corrections for conditions of use) >= Voc= 373 V Min Vmp at Max Temp: 279 Vdc Voc= i ;V continuous current per Table 310.15(B)(16). Vmp= 307 V Max Voc at Min Temp 413 Vdc Vmp= r;,. t ,tV Isc= 8 47 A Inverter Max Vdc Input 5001 Vdc Isc ; `A Imp= 798+A Max String Size 12 Imp= 1,_j ' c. Evaluate conductor temperature at terminations per Art 110.14(C). !cant= A Art 690.8(A)(1) 1-way wire length: 100 ft lcont= "r -1 :-,A Art 690 8(A)(1) Ampacity of wire derated for conditions of termination must be >= 1.a Conductor. G 10 USE-2/RHW-2 at 90 deg C Table 310.16 2.a Conductor 1:CAWG 10 THWN-2/USE-2 at 90 deg C:Table 310.16 continuous current*1.25. All branch terminations are rated at 75' C - . Conductor 1:' min. (cont*1.25=(Amps) 13.23 Icont*1.25=(Amps) 13.23 30 deg C ampacity= 40 I 30 deg C ampacity= 40 1 4. OCP Sizing 1.b Icont=(Amps) 10.59 2.b lcont=(Amps) 10.59 Start ampacity 40 Start ampacity 40 a. Round up to next size per Art 240.4(B) Temperature derate(%=F) 0.76 Temp.derate(%=F) 0.76 Conduit fill derate(%=f) 0.7 Cndt.fill derate(%=#) 1 5. Conductor Sizing per Art 690.8(B)(1) Derated ampacity 21.28 I Derated ampacity 30.4 I - Term 1 Term 2 _ a. Conductor must have 30 deg. C ampacity >= 125% of continuous 1.c Icont`1.25=(Amps) 13.23 Temptable 75degC 75degC current per Art 215.2(A)(1). Ampacity 40 2.c Icont•1.25=(Amps) 13.23 13.23 I Ampacity 35 35 I 1.d Icont*1.25=(Amps) 13.23 2.d EGC C AWG 10 C AWG 10 Art.250.122 . b. Conductor must have (after corrections for conditions of use) >= OCP size= 15 OCP size= 15 continuous current per Table 310.15(B)(16). Inverter Type A Output Combined Inverter Output 'SMA SB-3000US(240V) 1-way wire length: 20 ft Serce Voltage= 240 Volts c. Evaluate conductor temperature at terminations per Art 110.14(C). Icont= 12.50 A Art 690.8(A)(1) Total Inverter Power= Nameplate Watts 1-way wire length: 0 ft Ampacity of wire derated for conditions of termination must be >= 3.a (cont'1.25=(Amps) 15.63 A Art 690.8(B)(1) (cont=#of inverters•max inverter current Art 690.8(A)(1) continuous current*1.25. All inverter output terminations are rated at OCP size= 20 A Art.2Icont Amps) 12.50 A 3.b Conductor C AWG 10 THWN-2 at 90 deg C:Table 310.116.6(A) *6 4.a Icont`1..25 (Amps) 15.63 Art 690.8(6)(1) 75' C. (cont'1.25=(Amps) 15.63 OCP size= 20 A Art.240.6(A) 30 deg C ampacity= 40 I 4.b Conductor E AWG 06 THWN-2 at 90 deg C:Table 310.16 6. OCP Sizing 3.c Icont=(Amps) 12.50 (cont'1.25=(Amps) 15.63 Start ampacity 40 30 deg C ampacity= 75 I a. Round up to next size per Art 240.4(B) Temperature derate(%=F) 0.91 4.c Icont=(Amps) 12.50 Conduit fill derate(%=#) 1 Start ampacity 75 Derated ampacity 36.4 I Temp.derate(%=F) 0.91 7. Conductor Sizing per Art 690.8(B)(1) 3.d Icont'1.25=(Amps) 15.63 Cndt.fill derate(%=#) 1 a. Conductor must have 30 deg. C ampacity >= 125% of continuous Ampacity 35 I Derated ampacity 68.25 I " ..7;i:JP ERTINO current per Art 215.2(A)(1). 3.e EGC/GEC = D AWG 08 Art.690.47(C)(3),250.166(B) 4.d Icont•1.25=(Amps) 15 63 65 I lung Department b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.15(6)(16). ----- `� L �3 /IE1.'b'tED FOR CODE COMPLIANCEc. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity of wire derated for conditions of termination must be >= REA,k;w6d By,, • i5,,; ,qT continuous current*1.25. All inverter output terminations are rated at 75' C min. CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER UB-9501320 00 PREMISE OWNER AH,k DESCRIPTION: DESIGN: `1044 CONTAINED SHALL NOT BE USED FOR THE YING, DANIEL YING RESIDENCE EOBAN =. _ N NORBENEFITSH OF ANYONE EXCEPT SOLARCITYWHOLEINC., MARKET: MODULES 4 SolarCity NOR STALL IT BE DISCLOSED T E ECOLE OR IN RESI TRINA SOLAR TSM-245PC05 PA05.18 10496 S STEELING RD 2.45 KW PV Array ORGTANIZATION, TOIz TION, S IIN THE RECIPIENT'S IS / CUPERTINO, CA 95014 ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER MOUNTING SYSTEM: 3055 Clearviewway THE SALE AND USE OF THE RESPECTIVE S+P ST 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: INVERTER: PAGE NAME: SHEET: REV: DATE T:(650)S638-1028an F(650)638-1029 PERMISSION OF SOLARCITY INC. PPA SMA # SUNNY BOY 3000-US (408) 666-5863 ELECTRICAL CALCULATIONS PV 6 2/7/2013 (888)-SOL-CITY(765-2489)www.solardty.com PHOTOVOLTAIC DC DISCONNECT Label Location: Label Location: (DC), (INV) (AC), (LC) WARNING! ELECTRIC SHOCK HAZARD! Per Code: Solar Disconnect Per Code: Voc V CEC 690.53, NEC 690.53 CEC 690.17, NEC 690.14 (4) Vmp V WARNING- Electric Shock Hazard Isc A DO NOT TOIIJCH TERMINALS Imp A Terminals on both line and Load sides may be energized in the Open Position (888)SOL-CITY SolarCity SOLARCITY.COM Label Location: Label Location: WARNING - Dual Power Sources (INV), (AC), (LC), (M) DC DISCONNECT (DC), (INV) Second source is photovoltaic system WARNING- Electric Shock Hazard DO NOT TOUCH TERMINALS Terminals on doth line and Load sides Label Location: may be energized in the Open Position WARNING - Electric Shock Hazard (CB) inside DC VOLTAGE IS ALWAYS PRESENT WHEN No user serviceable partsSOLARMODULES ARE EXPOSED TO SUNLIGHT Contact authorized servicer for assistance I WARNING! 1 Label Location: PHOTOVOLTAIC POINT OF INTERCONNECTION Label Location: INVERTER OUTPUT CONNECTION.DO N0 _ (P01) WARNING! ELECTRIC SHOCK HAZARD! (P01) RELOCATE THIS OVERCURRENT DEVICE:' DO NOT TOUCH TERMINALS.TERMINALS ON BOTH THE LINE ANC LOAD SIDE MAY BE ENERG ZED PV POWER SOURCE MAXIMUM AC CIRCUIT OUTPUT PHOTOVOLTAIC Label Location: OPERATING CURRENT A AC DISCONNECT (AC), (D), (LC) OPERATING AC VOLTAGE v WARNING! ELECTRIC SHOCK HAZARD! Per Code: kg, CEC 690.8.A.3 & CEC 690.54, NEC 690.14 (c)(2) �� CUPERTINO OPERATING AC VOLTAGE V - (888)SOL-CITY � SolarCity SOLARCITY.COM Building Department MAXIMUM OPERATING CURRENT A , i; I _ r r...J 1 2013 Label Location: "���‘SolarCit ��� (888)SOL-CITY SOLARCITY.COM FZE�,'l:::,:::::y: _WED FOR CODE COMPLIANCE PV COMBINER BOX (CB) P\::,:: /`u a :./ r/� WARNING: Y ELECTRIC SHOCK HAZARD (AC): AC Disconnect Label Location: (C): Conduit CAUTION: SOLAR CIRCUIT (C) (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR Nb►4� ,...,11,...`j 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED -..- ■ San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, Labels ,,c, T:(650)638-1028 F:(650(638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE /1 oI� I�y (888)-SOL-CITY(765-2489)wwwsolarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. SMATechnical data Sunny Boy 3000-US Sunny Boy 3800-US Sunny Boy 4000-US 208VAC 240VAC 240 VAC 208VAC 240 VAC - SUNNY BOY 3000-US / 3800-US / 4000-US ill Input(DC) Max.recommended PV power(@ module STC) 3750 W 4750 W 4375 W 5000 W Max.DC power(@ cos p=I) 3200 W 4200 W 4200 W Max.DC voltage 500 V 600 V 600 V DC nominal voltage 250 V 310 V 310 V MPP voltage range 175-400 V 200-400 V 250-480 V 220-480 V 250-480 V Min.DC voltage/start voltage 175/228V 200/228V 250/285 V 220/285 V 250/285 V Max.input current/per string(at DC disconnect) 17A/17A 18A/18A 18A/18A 36 A@ combined terminal 36 A @ combined terminal 36 A @ combined terminal Number of MPP trackers/fused stings per MPP tracker 1/4(DC disconnect) Output(AC) 0 AC nominal power 3000 W 3800 W 3500 W 4000 W 1 Max.AC apparent power 3000 VA 3800 VA 3500 VA 4000 VA __ Nominal AC voltage/adjustable 208V/• 240V/• 240 V/- 208V/• 2,40V/• S _ AC voltage range 183-229V 211 -264 V 211-264 V 183-229 V 211-264 V 8 `5 AC grid frequency;range 60 Hz;59.3-60.5 Hz 60 Hz;59.3-60.5 Hz 60 Hz;59.3-60.5 Hz S 41t Illia . Max.output current 15 A <4% 13 A 16 A 17 A $ Power factor(cos p) 1 1 1 Phase conductors/connection phases 1/2 1/2 1/2 - <4% <4% Harmonics i. Efficiency Max.efficiency 96.0% 96.5% 96.8% 96.5% 96.8% CEC efficiency 95.0% 95.5% 96.0% 95.5% 96.0% e Protection devices 2 Y DC reverse-polarity protection • • • I .t AC short circuit protection • • • ; r0 Galvanically isolated/all-pole sensitive monitoring unit •/- •/- •% $ Protection class overro c I III I III I BI / category / / General data 1 i i 450/350/235 18 14 9 Dimensions W H D 'n mm ns DC Disconnect dimensions(W/H/D)in mm(in) 187/297/190(7/12/7.5) 1 Packing dimensions(W/H/D)in mm(in) 390/580/470(15/23/18.5) P F�_ DC Disconnect packing dimensions(W/H/D)in mm(in) 370/240/280(15/9/11) 5 '¢ Weight/DC Disconnect weight 38 kg (84 Ib)/3.5 kg (8 Ib) ;£ Packing weight/DC Disconnect packing weight 44 kg(97 Ib)/4 kg(9 Ib) 8 SB 3800-US NOW AVAILABLE Operating temperature range(full power) -25°C..+45°C(-13°F...+113°F) g Noise emission(typical) 40 dB(A) www.SMA-Solar.com 37 dB(A) Internal consumption at night 0.1 W 0.1 W 0.1 W 1 Topology LF transformer LF transformer IF transformer U Cooling concept OptiCool OptiCool OptiCool g Electronics protection rating/connection area NEMA 3R/NEMA 3R NEMA 3R/NEMA 3R NEMA 3R/NEMA 3R , C L us Features 8 ', 8 .�.ri �. Display:text line/graphic ••/- ••/- •/- w —^ Interfaces:R5485/Bluetooth 0/0 0/0 0/0 Warranty:10/15/20 years •/0/0 •/o/o 41/0/0 Certificates and permits(more available on request) UL1741,UL1998,IEEE 1547,FCC Part 15(Class A 8 B),CSA C22.2 No.107.1-2001 < 1 NOTE:US inverters ship with gray lids. I Data at nominal conditions •Standard features 0 Optional features -Not available Type designation SB 3000US SB 3800415-10 SB 4000US I Efficiency curve SUNNY BOY 4000US; Accessories 8 r 98 Boc SUNNY BOY 3000-US / 3800-US / 4000-Us 96 - - - - • (j �d85USP6NR� ,f TPBINVNR�y k g l 94 V O c CombiSwitdi Combiner Beu 90 F . DC disconnectand PV Simpldy wiring faadded h V„-250 V DC ono),combiner box wnerisnse and rofNy S 88 -.. V„-3I0VDC COMBOSWITCH ♦ /SBC863R or 5BC864 86 V„-480V DC I 1 1000 2000 3000 4000 - CUPERTINO PAC[VV] . i Bui!dinq Department rent Ih,ui o( 1 c,A • Toll Free+1 888 4 SMA USA ,� L J 1 273 - eusPatent I15>3sz54%1 www.SMA-America.com �, SMA America, LLC RL.`.'IrWEW, F O R CODE COMPLIANCE Rvviawed By: /74 a mono multi solutions Trinamount II FOR PITCHED ROOF TSM-PC05/ PA05.18 mono multi solutions ELECTRICAL DATA(rD STC TSM-225 TSM-230 TSM-235 TSM-240 TSM-245 DIMENSIONS OF PV MODULE TSM-PCOS/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 Peak Power Watts-Pers(Wp) 225 230 235 240 245 I 936 1 O YEAR Power Output Tolerance-Peru(%) 0/'-3 0/+3 0/n3 0/-•3 0/-r3 T,4namountll Maximum PowerVoltageVMr(V) 29.4 29.8 30.1 30.4 30.7 PRODUCT WARRANTY FOR MODULE Maximum Power Cu rent-Iwv(A) 7.66 7.72 7.81 7.89 7.98 fl Trleasolar AND MOUNTING SYSTEM Open Circuit Voltage-Voc(V) 36.9 37.037.1 37.2 37.3 FOR PITCHED ROOF Short Circuit _lsc(A) 8.20 8.26 8.31 8.37 8.47 15.0 5)( Module Efficiencyency qe(%) 13.7 4 1 14.4 14.7 FASTER TO INSTALL AL JA _ Values at Standard Test Conditions STC)AhMass AM1.5.Irradiance 1000W/m°,Cell Temperature 25°C). ULTRA LOW ELECTRICAL DATA @ NOCT TSM-225 TSM-230 TSM-235 TSM-240 TSM-245 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 RESISTANCE - Maximum Power(W) 16. 168 172 175 178 Maximum Power Voltage(V) 26.9 27.1 27.4 27.7 27.8 e 81 GROUND BOND CONNECTION °` Maximum Power Current(A) 6.12 6.20 6.27 6.32 6.41 10X BETTER THAN UL MINIMUM CRITERIA OROUND"ING"a. I Open Circuit Voltage(V) 33.8 33.9 34.0 34.1 34.2 ��� °'0R NO1 I Short Circuit Current(A) 6.62 6.68 6.70 6.75 6.83 NOCT Irradiance al 800W/m',Ambient Temperature 20°C,Wind Speed 1 M/s. Back View < ` • - _ • MECHANICAL DATA t •\. - Solar cells Multicrystalline 156•156mm(6 inches) - _I 11 I Cell orientation 60 cells(6•10) a `t •; is `s°• ti •v I j" Module dimension 1650•992,40mm(64.95•39.05•1.57 inches) T+ .1 "-• Z �• ••" -....n.-1~ Weight 20.3kg(44.8 Ib) o Glass High transparency solar glass 3.2mm(0.13 inches) 'Zr Frame Anodized aluminium alloy tl} j r 1-Box IP 65 rated . A-A Cables/Connector Photovoltaic Technology cable 4.0mm'(0.006 inches'), 1100mm(43.3 inches),MC4/H4 I-V CURVES OF PV MODULE TSM-230PC05/PA05.18 9P° ' IOODW/m' j BP° TEMPERATURE RATINGS . 740 Bones/mom Nominal Operating Cell 46°C)±2°C) 61° Temperature(NOCT) < 600W/m' 55° ._....... Temperature Coefficient of Per,, -0.43%/°C 3 4.00 400W/m'-__.-----' v 3e Temperature Coefficient of Voc -0.32%/°C 'W/m 29° -:_-,_._ Temperature Coefficient of Isc 0.047%/°C . >�U P E"TIN O SUITABLE FOR o� --- - ` P COMBINING PV MODULE EXPERTISE WITH A HIGHLY BuildingD- artment 00' 10P0 2000 309" 40n' Pa,' f INNOVATIVE MOUNTING SYSTEM SOLUTION. Voltage(V) MAXIMUM RATINGS It;; SolarCity SleekMountTM - Tile SolarCity SleekMountTM - Tile The SolarCity SleekMount hardware •Utilizes Zep Solar hardware and Zep compatible Installation Instructions solution is optimized to achieve superior modules. strength and aesthetics while minimizing j: Remove tile and locate rafter roof disruption and labor.The elimination •Interlock ETL listed to UL 1703 as ground bond means 2 Drill pilot holes of proper diameter for of visible rail ends and mounting clamps, combined with the addition of arraytrim fastener size per NDS section 1.1.3.2 Ground Zep UL and ETL listed to UL 467 as is f and a lower profile all contribute to a more grounding and bonding device Seal pilot holes with roofing sealant visually appealing system. SleekMount Place tile hook •Full system listed to UL 2703 for grounding utilizes modules with strengthened frames •Y 9 9 9 Install pursuant to NDS section 11.1.3 that attach directly to Zep standoffs, •Anodized components for corrosion resistance lags effectively eliminating the need for rail and with fender washer reducing the number of standoffs required. •Applicable for vent spanning functions Notch and reinstall tile • Attach Spanner Clamps and tighten firmly in place ,:. • Insert Cam Foot into Spanner Bar • Place modules Components A Zep Cam Foot A NFA B Zep Spanner Bar C 3/8"Machine Screw and Nut D Zep Spanner Bar Clamp E Tile Hook \6 F Lag Screw(2) C rfr F. moi• I4-41 CUPERTINO kw Building Department E Pl• FEB 1 4 2013 REVIEWED FOR CODE COMPLIANCE Reviewed By: /7/ArAtti SolarCity© January 2013 SolarCitym January 2013