11100155 (2) CITY OF CUPERTINO BUILDING PERMIT
:":ADDRESS: 10371 N BLANEY AVE CONTRACTOR:PCM HEATING AND AIR PERMIT NO: 11100155
CONDITIONING
OWNER'S NAME: DECKER JOHN T TRUSTEE&ET AL 247 SUNOL ST DATE ISSUED: 10/21/2011
VNER'S PHONE: 4087187738 SAN JOSE,CA 95126 PHONE NO:(408)365-7004
LJ LICENSED CONTRACTOR'S DECLARATION
BUILDING PERMIT INFO: BLDG ELECT PLUMB
License Class a Lic.# '3 7 L/ V
MECH RESIDENTIAL COMMERCIAL
Contractor / Date/e) -
I hereby a r m that I am lice e undeTtIt prommons o apter L' JOB DESCRIPTION:REPLACE FURNACE&ADD A/C UNIT
(commencing with Section 7000)of Division 3 of the Business&Professions
Code and that my license is in full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
I have and will maintain a certificate of consent to self-insure for Worker's
Compensation,as provided for by Section 3700 of the Labor Code,for the
performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$6444
I have and will maintain Worker's Compensation Insurance,as provided for by
Section 3700 of the Labor Code,for the performance of the work for which this
permit is issued. APN Number:31633004.00 Occupancy Type:
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is
correct.I agree to comply with all city and county ordinances and state laws relating PERMIT EXPIRES IF WORK IS NOT STARTED
to building construction,and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We)agree to save WITHIN 180 DAYS OF PERMIT ISSUANCE OR
indemnify and keep harmless the City of Cupertino against liabilities,judgments, 180 DAYS FROM LAST CALLED INSPECTION.
costs,and expenses which may accrue against said City in consequence of the
granting of this permit. A. iti nally,the applicant understands and will comply
with all non-point . ations per the Cupertino Municipal Code,Section Issued by• Date: ( 4- 1 i- 6
9.18. /
Signature ' 't.:. Date /0-2-1-11
RE-ROOFS:
OWNER-BUILDER DECLARATION All roofs shall be inspected prior to any roofing material being installed.If a roof is
installed without first obtaining an inspection,I agree to remove all new materials for
thereby affirm that I am exempt from the Contractor's License Law for one of inspection.
the following two reasons:
I,as owner of the property,or my employees with wages as their sole compensation, Signature of Applicant Date:
will do the work,and the structure is not intended or offered for sale(Sec.7044,
Business&Professions Code)
I,as owner of the property,am exclusively contracting with licensed contractors to ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER
construct the project(Sec.7044,Business&Professions Code).
I hereby affirm under penalty of perjury one of the following three HAZARDOUS MATERIALS DISCLOSURE
declarations: I have read the hazardous materials requirements under Chapter 6.95 of the
I have and will maintain a Certificate of Consent to self-insure for Worker's California Health&Safety Code,Sections 25505,25533,and 25534. I will maintain
Compensation,as provided for by Section 3700 of the Labor Code,for the compliance with the Cupertino Municipal Code,Chapter 9.12 and the Health&
performance of the work for which this permit is issued. Safety Code,Section 25532(a)should I store or handle hazardous material.
I have and will maintain Worker's Compensation Insurance,as provided for by Additionally,should I use equipment or devices which emit hazardous air
Section 3700 of the Labor Code,for the performance of the work for which this contaminants as defined by the Bay Area Air Quality Management District I will
permit is issued. maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the
Health&Sal C., •, ctions 25505,25533,and 25534.
I certify that in the performance of the work for which this permit is issued,I shall /
not employ any person in any manner so as to become subject to the Worker's Owner /� agent:
Compensation laws of California. If,after making this certificate of exemption,I . Date:,Cj aJ—//
become subject to the Worker's Compensation provisions of the Labor Code,I must
forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of work's
APPLICANT CERTIFICATION for which this permit is issued(Sec.3097,Civ C.)
I certify that I have read this application and state that the above information is Lender's Name
correct.I agree to comply with all city and county ordinances and state laws relating
to building construction,and hereby authorize representatives of this city to enter Lender's Address
upon the above mentioned property for inspection purposes.(We)agree to save
indemnify and keep harmless the City of Cupertino against liabilities,judgments,
and expenses which may accrue against said City in consequence of the ARCHITECT'S DECLARATION
ng of this permit.Additionally,the applicant understands and will comply I understand my plans shall be used as public records.
win all non-point source regulations per the Cupertino Municipal Code,Section
9.18. Licensed Professional
Signature Date
CITY OF CUPERTINO
7 ITEMS OF 7 PERMIT RECEIPT OPERATOR: patg
COPY # : 1
Sec: Twp: Rng: Sub: Blk: Lot:
APN • 31633004 . 00
DATE ISSUED • 10/21/2011
RECEIPT # • BS000015108
REFERENCE ID # . . . : 11100155
SITE ADDRESS • 10371 N BLANEY AVE
SUBDIVISION
CITY • CUPERTINO
IMPACT AREA
OWNER • DECKER JOHN T TRUSTEE & ET AL
ADDRESS • 10371 N BLANEY AVE
CITY/STATE/ZIP . . . : CUPERTINO, CA 95014-2454
RECEIVED FROM • PACIFIC COAST MECHA
CONTRACTOR • MARK A TORRISI LIC # 18612
COMPANY • PCM HEATING AND AIR CONDITIONI
ADDRESS • 247 SUNOL ST
CITY/STATE/ZIP . . . : SAN JOSE, CA 95126
TELEPHONE • (408) 365-7004
FEE ID UNIT QUANTITY AMOUNT PD-TO-DT THIS REC NEW BAL
lADMIN HOURS 1. 00 41. 00 0. 00 41.00 0. 00
1BCBSC VALUATION 6,444 .00 1. 00 0. 00 1. 00 0. 00
1BREMAIRHA NO.UNITS 1.00 65. 00 0. 00 65. 00 0. 00
1BSEISMICR VALUATION 6,444 .00 0.64 0. 00 0.64 0. 00
1MFR=<100 UNITS 1 .00 130. 00 0.00 130. 00 0. 00
1MPERMITFE FLAT RATE 1 .00 44 . 00 0 . 00 44 . 00 0. 00
1TRAVDOC FLAT RATE 1 .00 44 . 00 0 . 00 44 .00 0 .00
TOTAL PERMIT : 325.64 0. 00 325 .64 0. 00
METHOD OF PAYMENT AMOUNT REFERENCE NUMBER
CHECK 325 .64 #9104
TOTAL RECEIPT : 325.64
VOICE ID DESCRIPTION VOICE ID DESCRIPTION
505 FINAL ELECTRICAL 507 FINAL PLUMBING
508 FINAL MECHANICAL
CITY OF CUPERTINO
FEE ESTIMATOR- BUILDING DIVISION
,, ADDRESS: 10371 n. blaney ave. DATE: 10/21/2011 REVIEWED BY: bob s.
*51."1. APN: BP#: 'VALUATION: $6,444
PERMIT TYPE: Mechanical Permit PLAN CHECK TYPE: Alteration /Addition/ Repair
PRIMARY PENTAMATION FURN/AC
UUSE: SFD or Duplex PERMIT TYPE:
WORK replace furnace add a/c unit.
SCOPE
APPLIANCE/EQUIP TYPE FEE ID QTY UNITS BP FEES
A/C Units (<=10K cfm) 1BREMAIR 1 # $65
Furnace, Forced-Air 1MFR=<100 1 # $130
TOTALS: $195.00
Mech.Plan Check 10.0 I hrs $0.00 I I u
Mech.Permit Fee: 1MPERMIT
Other Mech.Insp. 0.0 hrs $44.00 - n n
NOTE: This estimate does not include fees due to other Departments(Le.Planning,Public Works,Fire,Sanitary Sewer District,School
District,etc.). These fees are based on the prelinsnarj information available and are only an estimate. Contact the Dept for addn'l info.
FEE ITEMS (Fee Resolution 11-053 EY 7/1 11) FEE QTY/FEE MISC ITEMS
A
PME Plan Check: $0.00
PME Unit Fee: $195.00
PME Permit Fee: $44.00
Administrative Fee: IADMIN $41.00
Work Without Permit? o Yes ® No $0.00
Travel Documentation Fee: 1TRAVDOC $44.00 i
Strong Motion Fee: 1BSEISMICR $0.64 Select an Administrative Item
Bldg Stds Commission Fee: 1BCBSC $1.00
SUBTOTALS: $325.64 $0.00 TOTAL FEE: $325.64
Revised: 10/01/2011
tIia01 .- 7---
,
-
, j/ GENERAL PERMIT APPLICATION M E P
J� COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION
4j.„r'\ 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 MISC
s
(408)777-3228• FAX(408)777-3333•buildinq ancupertino.orq
CUPERTINO
PLUMBING ®MECHANICAL igELECTRICAL ❑MISCELLANEOUS (((
PROJECT ADDRESS APN# I\' 0 /�l�
in3� i 6. P)laney i nue_ Cti -h''no, ^C D I LI T/3 v 1-f
-
OWNER NAME i n PHONE E-MAIL
J C�(e,^ LIDS--r)I S- 0 3�
STREET ADDRESS CITY, STATE,ZIP °151I'w FAX
I( R vIr�lnlcti r/aee. �,a,I nSP CA lL
CONTACT NAME PHONE E-MAIL
5 dvneJ
STREET ADDRESS CITY,STATE, ZIP FAX
W OWNER 0 OWNER-BUILDER 0 OWNER AGENT VI CONTRACTOR 0 CONTRACTOR AGENT 0 ARCHITECT 0 ENGINEER 0 DEVELOPER 0 TENANT
CONTRACTOR NAME , LICENSE NUMBS LICENSE TYPE BUS.LIC#
1YlWIc . 10((I 5 i Io 3 i-i Cao I x if) 1 a
O.
-(
OMPAN NA E E-MAIL F
rn I�eaR nc�
owl Qi r Cbind'lib I ncs 1 nLlm a
.SS eTYSTATE ZIP
es a) 61oe j\r/ Jloa I . t ( t-9'5-0'j q`I
STREET q /DCJUI DI fret-L af/IC)) Y' Cil 1 +GI 6 PHONE-310 5--9boq
ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC#
COMPANY NAME E-MAIL FAX
STREET ADDRESS CITY,STATE,ZIP PHONE
USE OF ISI SFD or DUPLEX 0 MULTI-FAMILY PROJECT IN WILDLAND 0 YES PROJECT IN 0 YES IS THE BLDG AN 0 YES
BUILDING: 0 COMMERCIAL URBAN INTERFACE AREA IA NO FLOOD ZONE lin NO EICHLER HOME? igi NO
DESCRIPTION OF WORK �e pee QN.i 5 -n a -R"AAL.it_ ad 1 Q1'i cty►d/h isi n 46
UvtAL- 1 feu p4acie, ali_ I uraj- A-) e,
TOTAL VALUATION: 4 (I,,1 1/14, (3 RECEIVED BY: 1)cb`
By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this
application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local
ordinances and state laws relatingt building cons ction.( I authorize representatives of Cupertino to enter the above-identified property for inspection purposes.
Signature of Applicant/Agent: � l_x.C,LLe_Y Q.__ Date: I Di4 (
SUPPLE NTAL INFORMATION REQUIRED oW USE ONLY
W COVER-THE-COUNTER
0 EXPRESS
�"p 0 STANDARD
zU
a 0 LARGE
a
0 MAJOR
MEPMiscApp_2011.doc revised 06/21/11
Energy Calculations
Of
NEW FURNACE TO REPLACE EXISTING
For
MR. JOHN DECKER'S RESIDENCE
At
10371 North Blaney Ave, Cupertino, CA 95014
By
Technical Analysis, Design & Engineerings
P. O. Box 2450 cy;
Cupertino, CA 95015-2450
408-202-4368
Job #: TADE2011-519
Oct. 19, 2011 `
_.i
V
"
NY ,, ?12
TABLE OF CONTENTS TOC
Project Title Decker Res. Furance Calcs Date. .10/20/11 15:16:35
Project Address 10371 N. BLANEY AVE ******
CUPERTINO, CA 95014 *v8.1*
Documentation AuthorTechnical Analysis D & E ****** Building Permit #
Technical Analysis, Design & Engineering
1280 Scott Blvd. , Suite B Plan Check / Date
Santa Clara, CA 95050
(408) 202-4368 Field Check/ Date
Climate Zone 04
Compliance Method MICROPAS8 v8.1 for 2008 CEC Standards (r03)
I MICROPAS8 v8.1 File-DECKER Wth-CTZ04S08
I User#-MP0580 User-Technical Analysis, Desig Run-Decker Furnace
TABLE OF CONTENTS
Report Page
FORM CF-1R 1
FORM MF-1R 6
HVAC SIZING 11
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD
CF-1R Page 1
Project Title Decker Res. Furance Calcs Date. .10/20/11 15:16:35
BLANEY AVE ******
10371 N.
Project Address
CUPERTINO, CA 95014 *v8 .1* 3 3
ocumentation AuthorTechnical Analysis D & E ****** 3 Building Permit # 3
Technical Analysis, Design & Engineering 3 Plan Check / Date 3
1280 Scott Blvd. , Suite B 3 3
Santa Clara, CA 95050 3 Field Check/ Date 3
(408) 202-4368
Climate Zone 04
Compliance Method MICROPAS8 v8.1 for 2008 CEC Standards (r03)
3
3 MICROPAS8 v8.1 File-DECKER Wth-CTZO4S08 3
3 User#-MP0580 User-Technical Analysis, Design Run-Decker Furnace
0
o MICROPAS8 ENERGY USE SUMMARY
0
O 0
o Energy Use Standard Proposed Compliance Percent °
o (kTDV/sf-yr) Design Design Margin Improvement °
o Space Heating 24 . 92 29.67 -4.75 -19.1% 0
o Space Cooling 7.58 2.49 5.09 67.2%
o Ventilation Fans 0.85 0.85 0.00 0.0% o
0
o Total 33.35 33.01 0.34 1.0% °
0
o *** Building does comply with Computer Performance *** 0
*** Water Heating not calculated ***
GENERAL INFORMATION
HERS Verification Not Required
Conditioned Floor Area 1680 sf
Building Type Single Family Detached
Construction Type Whole House
Natural Gas at Site Yes
Building Front OrientationFront Facing 0 deg (N)
Number of Dwelling Units1
Number of Building Stories1
Weather Data Type FullYear
Floor Construction TypeRaised Floor
Number of Building Zones1
Conditioned Volume 13440 cf
Slab-On-Grade Area 0 sf
Glazing Percentage 12.1 % of floor area
Average Glazing U-factor0. 65 Btu/hr-sf-F
Average Glazing SHGC 0. 4
Average Ceiling Height 8 ft
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 2
Project Title Decker Res. Furance Calcs Date. .10/20/11 15:16:35
MICROPAS8 v8.1 File-DECKER Wth-CTZO4S08 I
User#-MP0580 User-Technical Analysis, Desig Run-Decker Furnace 1
BUILDING ZONE INFORMATION
Floor # of # of Cond- Thermo- Vent Vent Verified
Area Volume Dwell Peop- it- stat Height Area Leakage or
Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap
HOUSE - Existing
Residence 1680 13440 1.00 4 .0 Yes Setback 2.0 Standard No
ATTIC AND ROOF DETAILS
Frame R- R-
Roof Roof Re- Emiss- Frame Spac- Value Value Vent
Mass Rise flect- ivity Depth ing Above Below Area Vent
Roof Type (lb/sqft) ance (in. ) (in. ) Deck Deck Ratio High
HOUSE - Existing
Asphalt 5 4 :12 0.08 0.90 5.5 16 oc 0.00 0.00 1/150 0.00
OPAQUE SURFACES
U- Sheath- Solar Appendix
Frame Area fact- Cavity ing Act Gains JA4 Location/
Surface Type (sf) or R-val R-val Azm Tilt Reference Comments
-OUSE - Existing
. Wall Wood 324 0.102 13 0 0 90 Yes 4.3.1 A3
2 Wall Wood 378 0.102 13 0 90 90 Yes 4.3.1 A3
3 Wall Wood 282 0.102 13 0 180 90 Yes 4.3.1 A3
4 Wall Wood 221 0.102 13 0 270 90 Yes 4.3.1 A3
5 Door Wood 20 0.500 0 0 0 90 Yes 4.5.1 A4
6 FloorExt Wood 1680 0.048 19 0 n/a 0 No 4 .4.2 A4
7 AtticRad Wood 1680 0.032 30 0 n/a 0 No 4.2.1 A8
FENESTRATION SURFACES
Exterior
Area U- Act Shade
Orientation (sf) factor SHGC Azm Tilt Type Location/Comments
HOUSE - Existing
1 Wind Front (N) 52.0 0.650 0.400 0 90 Woven Fl/Metal Operable Low E2
2 Wind Left (E) 10.0 0.650 0.400 90 90 Woven L1/Metal Operable Low E2
3 Wind Back (S) 114.0 0.650 0.400 180 90 Woven B1/Metal Operable Low E2
4 Door Right (W) 27.0 0.650 0.400 270 90 Woven R1/Metal Patio Door Low
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 3
Project Title Decker Res. Furance Calcs Date. .10/20/11 15:16:35
1 MICROPAS8 v8.1 File-DECKER Wth-CTZ04S08
User#-MP0580 User-Technical Analysis, Desig Run-Decker Furnace I
OVERHANGS
---Window Overhang
Area Left Right
Surface (sf) Width Height Depth Height Extension Extension
HOUSE - Existing
1 Window 52.0 n/a 4.0 2.0 1.5 n/a n/a
2 Window 10.0 n/a 5.0 2.0 0.5 n/a n/a
3 Window 114.0 n/a 4.0 2.0 0.5 n/a n/a
4 Door 27.0 n/a 4 .0 2.0 0.5 n/a n/a
HVAC SYSTEMS
Verified
Verified Verified Verified Verified Maximum
System Minimum Refrig Charge Adequate Fan Watt Cooling
Type Efficiency EER or CID Airflow Draw Capacity
HOUSE - Existing
Furnace 0.780 AFUE n/a n/a n/a n/a n/a
NoCooling 13.00 SEER No No No No No
HVAC SIZING
Verified
Total Sensible Design Maximum
Heating Cooling Cooling Cooling
System Load Load Capacity Capacity
Type (Btu/hr) (Btu/hr) (Btu/hr) (Btu/hr)
HOUSE - Existing
Furnace 31065 n/a n/a n/a
NoCooling n/a 11109 12731 n/a
Sizing Location CUPERTINO
Winter Outside Design 28 F
Winter Inside Design 70 F
Summer Outside Design 86 F
Summer Inside Design 75 F
Summer Range 30 F
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 4
Project Title Decker Res. Furance Calcs Date. .10/20/11 15:16:35
1 MICROPAS8 v8.1 File-DECKER Wth-CTZ04S08 I
User#-MP0580 User-Technical Analysis, Desig Run-Decker Furnace I
DUCT SYSTEMS
Verified Verified Verified
System Duct Duct Duct Surface Buried
Type Location R-value Leakage Area Ducts
HOUSE - Existing
Furnace Crawlspace R-4 .2 No No No
NoCooling Crawlspace R-4 .2 No No No
FAN SYSTEMS
Flow Power
System Type (cfm) (W/cfm)
HOUSE - Existing
Standard 46.8 .25
SPECIAL FEATURES AND MODELING ASSUMPTIONS
*** Items in this section should be documented on the plans, ***
*** installed to manufacturer and CEC specifications, and ***
*** verified during plan check and field inspection. ***
This building incorporates Ducts in a Crawlspace or Basement Location.
- ' 1 supply registers must be within 2 ft of floor.
This building incorporates a Radiant Barrier.
This building incorporates a Cool Roof.
This building incorporates non-standard Fenestration Shading.
This building does not have a cooling system installed.
REMARKS
New furnace for the whole house.
CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF-1R Page 5
Project Title Decker Res. Furance Calcs Date. .10/20/11 15:16:35
MICROPAS8 v8.1 File-DECKER Wth-CTZ04S08
User#-MP0580 User-Technical Analysis, Desig Run-Decker Furnace
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance
specifications needed to comply with Title-24, Parts 1 and 6 of the
California Code of Regulations, and the administrative regulations to
implement them. This certificate has been signed by the individual with
overall design responsibility.
DESIGNER or OWNER DOCUMENTATION AUTHOR
Name. . . . JOHN DECKER Name. . . . Technical Analysis D & E
Company. HOME OWNER Company. Technical Analysis, Design & Eng
Address. 10371 N. BLANEY AVE Address. 1280 Scott Blvd., Suite B
CUPERTINO, CA 95014 Santa Clara, CA 95050
Phone. . . 408-972-0792 Phone. . . (408) 202-4368
License. NONE
Signed. . Signed. .
(date) (date)
ENFORCEMENT AGENCY
Name. . . .
Title. . .
Agency. .
Phone. . .
Signed. .
(date)
MANDATORY MEASURES SUMMARY: RESIDENTIAL MF-1R Page 6
Project Title Decker Res. Furance Calcs Date. .10/20/11 15:16:35
Project Address 10371 N. BLANEY AVE ******
CUPERTINO, CA 95014 *v8.1*
,cumentation AuthorTechnical Analysis D & E ****** Building Permit #
Technical Analysis, Design & Engineering Plan Check / Date
1280 Scott Blvd. , Suite B
Santa Clara, CA 95050
(408) 202-4368 Field Check/ Date
Climate Zone 04
Compliance Method MICROPAS8 v8.1 for 2008 CEC Standards (r03)
MICROPAS8 v8.1 File-DECKER Wth-CTZ04S08
User#-MP0580 User-Technical Analysis, Desig Run-Decker Furnace
NOTE: Low-rise residential buildings subject to the Standards must comply with
all applicable mandatory measures listed, regardless of the compliance
approach used. More stringent energy measures listed on the Certificate of
Compliance (CF-1R, CF-1R-ADD, or CF-1R-ALT Form) shall supersede the items
marked with an asterisk (*) below. This Mandatory Measures Summary shall be
incorporated into the permit documents and the applicable features shall be
considered by all parties as minimum component performance specifications
whether they are shown elsewhere in the documents or in this summary. Submit
all applicable sections of the MF-1R Form with plans.
BUILDING ENVELOPE MEASURES:
116 (a) 1: Doors and windows between conditioned and unconditioned spaces are
manufactured to limit air leakage.
116 (a) 4: Fenestration products (except field-fabricated windows) have a label
listing the certified U-Factor, certified Solar Heat Gain Coefficient (SHGC) ,
and infiltration that meets the requirements of 10-111 (a) .
- ' 7: Exterior doors and windows are weather-stripped; all joints and
enetrations are caulked and sealed.
118 (a) : Insulation specified or installed meets Standards for Insulating
Material. Indicate type and include on CF-6R Form.
118 (i) : The thermal emittance and solar reflectance values of the cool roofing
material meets the requirements of 118 (i) when the installation of a Cool Roof
is specified on the CF-1R Form.
*150 (a) : Minimum R-19 insulation in wood-frame ceiling or equivalent U-factor.
150 (b) : Loose fill insulation shall conform with manufacturer's installed
design labeled R-Value.
*150 (c) : Minimum R-13 insulation in wood-frame wall or equivalent U-factor.
*150 (d) : Minimum R-13 insulation in raised wood-frame floor or equivalent
U-factor.
150 (f) : Air retarding wrap is tested, labeled, and installed according to ASTM
E1677-95 (2000) when specified on the CF-1R Form.
150 (g) : Mandatory Vapor barrier installed in Climate Zones 14 or 16.
150 (1) : Water absorption rate for slab edge insulation material alone without
facings is no greater than 0.3%; water vapor permeance rate is no greater than
2.0 perm/inch and shall be protected from physical damage and UV light
deterioration.
FIREPLACES, DECORATIVE GAS APPLIANCES AND GAS LOG MEASURES:
150 (e) 1A: Masonry or factory-built fireplaces have a closable metal or glass
MANDATORY MEASURES SUMMARY: RESIDENTIAL MF-1R Page 7
Project Title Decker Res. Furance Calcs Date. .10/20/11 15:16:35
MICROPASB v8.1 File-DECKER Wth-CTZ04S08
User#-MP0580 User-Technical Analysis, Desig Run-Decker Furnace
door covering the entire opening of the firebox.
150 (e) 1B: Masonry or factory-built fireplaces have a combustion outside air
intake, which is at least six square inches in area and is equipped with a
with a readily accessible, operable, and tight-fitting damper and or a
combustion-air control device.
150 (e)2: Continuous burning pilot lights and the use of indoor air for cooling
a firebox jacket, when that indoor air is vented to the outside of the
building, are prohibited.
SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES:
110-113: HVAC equipment, water heaters, showerheads, faucets and all other
regulated appliances are certified by the Energy Commission.
113 (c) 5: Water heating recirculation loops serving multiple dwelling units and
High-Rise residential occupancies meet the air release valve, backflow
prevention, pump isolation valve, and recirculation loop connection
requirements of 113 (c) 5.
115: Continuously burning pilot lights are prohibited for natural gas:
fan-type central furnaces, household cooking appliances (appliances with an
electrical supply voltage connection with pilot lights that consume less than
150 Btu/hr are exempt) , and pool and spa heaters.
150 (h) : Heating and/or cooling loads are calculated in accordance with ASHRAE,
SMACNA or ACCA.
150 (i) : Heating systems are equipped with thermostats that meet the setback
requirements of Section 112 (c) .
150 (j) 1A: Storage gas water heaters rated with an Energy Factor no greater
'han the federal minimal standard are externally wrapped with insulation
aving an installed thermal resistance of R-12 or greater.
150 (j) 1B: Unfired storage tanks, such as storage tanks or backup tanks for
solar water-heating system, or other indirect hot water tanks have R-12
external insulation or R-16 internal insulation where the internal insulation
R-value is indicated on the exterior of the tank.
150 (j )2: First 5 feet of hot and cold water pipes closest to water heater
tank, non-recirculating systems, and entire length of recirculating sections
of hot water pipes are insulated per Standards Table 150-B.
150 (j)2: Cooling system piping (suction, chilled water, or brine lines) ,and
piping insulated between heating source and indirect hot water tank shall be
insulated to Table 150-B and Equation 150-A.
150 (j) 2: Pipe insulation for steam hydronic heating systems or hot water
systems >15 psi, meets the requirements of Standards Table 123-A.
150 (j) 3A: Insulation is protected from damage, including that due to sunlight,
moisture, equipment maintenance, and wind.
150 (j) 3A: Insulation for chilled water piping and refrigerant suction lines
includes a vapor retardant or is enclosed entirely in conditioned space.
150 (j) 4: Solar water-heating systems and/or collectors are certified by the
Solar Rating and Certification Corporation.
DUCTS AND FANS MEASURES:
150 (m) 1: All air-distribution system ducts and plenums installed, are sealed
MANDATORY MEASURES SUMMARY: RESIDENTIAL MF-1R Page 8
Project Title Decker Res. Furance Calcs Date. .10/20/11 15:16:35
MICROPAS8 v8.1 File-DECKER Wth-CTZ04S08
User#-MP0580 User-Technical Analysis, Desig Run-Decker Furnace
and insulated to meet the requirements of CMC Sections 601, 602, 603, 604, 605
and Standard 6-5; supply-air and return-air ducts and plenums are insulated to
a minimum installed level of R-4 .2 or enclosed entirely in conditioned space.
Openings shall be sealed with mastic, tape or other duct-closure system that
meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol
sealant that meets the requirements of UL 723. If mastic or tape is used to
seal openings greater than 1/4 inch, the combination of mastic and either mesh
or tape shall be used.
150 (m) 1: Building cavities, support platforms for air handlers, and plenums
defined or constructed with materials other than sealed sheet metal, duct
board or flexible duct shall not be used for conveying conditioned air.
Building cavities and support platforms may contain ducts. Ducts installed in
cavities and support platforms shall not be compressed to cause reductions in
the cross-sectional area of the ducts.
150 (m)2D: Joints and seams of duct systems and their components shall not be
sealed with cloth back rubber adhesive duct tapes unless such tape is used in
combination with mastic and draw bands.
150 (m) 7: Exhaust fan systems have back draft or. automatic dampers.
150 (m) 8: Gravity ventilating systems serving conditioned space have either
automatic or readily accessible, manually operated dampers.
150 (m) 9: Insulation shall be protected from damage, including that due to
sunlight, moisture, equipment maintenance, and wind. Cellular foam insulation
shall be protected as above or painted with a coating that is water retardant
and provides shielding from solar radiation that can cause degradation of the
material.
150 (m) 10: Flexible ducts cannot have porous inner cores.
' 50 (o) : All dwelling units shall meet the requirements of ANSI/ASHRAE Standard
)2.2-2007 Ventilation and Acceptable Indoor Air Quality in Low-Rise
Residential Buildings. Window operation is not a permissible method of
providing the Whole Building Ventilation required in Section 4 of that
Standard.
POOL AND SPA HEATING SYSTEMS AND EQUIPMENT MEASURES:
114 (a) : Any pool or spa heating system shall be certified to have: a thermal
efficiency that complies with the Appliance Efficiency Regulations; an on-off
switch mounted outside of the heater; a permanent weatherproof plate or card
with operating instructions; and shall not use electric resistance heating or
a pilot light.
114 (b) 1: Any pool or spa heating equipment shall be installed with at least
36" of pipe between filter and heater, or dedicated suction and return lines,
or built-up connections for future solar heating
114 (b) 2: Outdoor pools or spas that have a heat pump or gas heater shall have
a cover.
114 (b) 3: Pools shall have directional inlets that adequately mix the pool
water, and a time switch that will allow all pumps to be set or programmed to
run only during off-peak electric demand periods.
150 (p) : Residential pool systems or equipment meet the pump sizing, flow rate,
piping, filters, and valve requirements of 150 (p) .
MANDATORY MEASURES SUMMARY: RESIDENTIAL MF-1R Page 9
Project Title Decker Res. Furance Calcs Date. .10/20/11 15:16:35
MICROPAS8 v8.1 File-DECKER Wth-CTZ04S08
User#-MP0580 User-Technical Analysis, Desig Run-Decker Furnace
RESIDENTIAL LIGHTING MEASURES:
150 (k) 1: High efficacy luminaires or LED Light Engine with Integral Heat Sink
has an efficacy that is no lower than the efficacies contained in Table 150-C
and is not a low efficacy luminaire as specified by 150 (k)2.
150 (k) 3: The wattage of permanently installed luminaires shall be determined
as specified by 130 (d) .
150 (k) 4: Ballasts for fluorescent lamps rated 13 Watts or greater shall be
electronic and shall have an output frequency no less than 20 kHz.
150 (k) 5: Permanently installed night lights and night lights integral to a
permanently installed luminaire or exhaust fan shall contain only high
efficacy lamps meeting the minimum efficacies contained in Table 150-C and
shall not contain a line-voltage socket or line-voltage lamp holder; OR shall
be rated to consume no more than five watts of power as determined by 130 (d) ,
and shall not contain a medium screw-base socket.
150 (k) 6: Lighting integral to exhaust fans, in rooms other than kitchens,
shall meet the applicable requirements of 150 (k) .
150 (k) 7: All switching devices and controls shall meet the requirements of
150 (k)7.
150 (k) 8: A minimum of 50 percent of the total rated wattage of permanently
installed lighting in kitchens shall be high efficacy.
EXCEPTION: Up to 50 watts for dwelling units less than or equal to 2,500 ft2
or 100 watts for dwelling units larger than 2,500 ft2 may be exempt from the
50°% high efficacy requirement when: all low efficacy luminaires in the kitchen
are controlled by a manual on occupant sensor, dimmer, energy management
system (EMCS) , or a multi-scene programmable control system; and all
-permanently installed luminaries in garages, laundry rooms, closets greater
han 70 square feet, and utility rooms are high efficacy and controlled by a
manual-on occupant sensor.
150 (k) 9: Permanently installed lighting that is internal to cabinets shall use
no more than 20 watts of power per linear foot of illuminated cabinet.
150 (k) 10: Permanently installed luminaires in bathrooms, attached and detached
garages, laundry rooms, closets and utility rooms shall be high efficacy.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed
provided that they are controlled by a manual-on occupant sensor certified to
comply with the applicable requirements of 119.
EXCEPTION 2: Permanently installed low efficacy luminaires in closets less
than 70 square feet are not required to be controlled by a manual-on occupant
sensor.
150 (k) 11: Permanently installed luminaires located in rooms or areas other
than in kitchens, bathrooms, garages, laundry rooms, closets, and utility
rooms shall be high efficacy luimnaires.
EXCEPTION 1: Permanently installed low efficacy luminaires shall be allowed
provided they are controlled by either a dimmer switch that complies with the
applicable requirements of 119, or by a manual-on occupant sensor that
complies with the applicable requirements of 119.
EXCEPTION 2: Lighting in detached storage building less than 1000 square feet
located on a residential site is not required to comply with 150 (k) 11.
150 (k) 12: Luminaires recessed into insulated ceilings shall be listed for zero
clearance insulation contact (IC) by Underwriters Laboratories or other
MANDATORY MEASURES SUMMARY: RESIDENTIAL
MF-1R Page 10
Project Title Decker Res. Furance Calcs Date. .10/20/11 15:16:35
MICROPAS8 v8.1 File-DECKER Wth-CTZ04S08
User#-MP0580 User-Technical Analysis, Desig Run-Decker Furnace
nationally recognized testing/rating laboratory; and have a label that
certifies the lumiunaire is airtight with air leakage less then 2.0 CFM at 75
Pascals when tested in accordance with ASTM E283; and be sealed with a gasket
or caulk between the luminaire housing and ceiling.
150 (k) 13: Luminaires providing outdoor lighting, including lighting for
private patios in low-rise residential buildings with four or more dwelling
units, entrances, balconies, and porches, which are permanently mounted to a
residential building or to other buildings on the same lot shall be high
efficacy.
EXCEPTION 1: Permanently installed outdoor low efficacy luminaires shall be
allowed provided that they are controlled by a manual on/off switch, a motion
sensor not having an override or bypass switch that disables the motion
sensor, and one of the following controls: a photocontrol not having an
override or bypass switch that disables the photocontrol; OR an astronomical
time clock not having an override or bypass switch that disables the
astronomical time clock; OR an energy management control system (EMCS) not
having an override or bypass switch that allows the luminaire to be always on
EXCEPTION 2: Outdoor luminaires used to comply with Exceptionl to 150 (k) 13 may
be controlled by a temporary override switch which bypasses the motion sensing
function provided that the motion sensor is automatically reactivated within
six hours.
EXCEPTION 3: Permanently installed luminaires in or around swimming pool,
water features, or other location subject to Article 680 of the California
Electric Code need not be high efficacy luminaires.
150 (k) 14: Internally illuminated address signs shall comply with Section 148;
OR not contain a screw-base socket, and consume no more than five watts of
lower as determined according to 130 (d) .
0 (k) 15: Lighting for parking lots and carports with a total of for 8 or more
vehicles per site shall comply with the applicable requirements in Sections
130, 132, 134, and 147. Lighting for parking garages for 8 or more vehicles
shall comply with the applicable requirements of Sections 130, 131, 134, and
146.
150 (k) 16: Permanently installed lighting in the enclosed, non-dwelling spaces
of low-rise residential buildings with four or more dwelling units shall be
high efficacy luminaires.
EXCEPTION: Permanently installed low efficacy luminaires shall be allowed
provided that they are controlled by an occupant sensor(s) certified to comply
with the applicable requirements of 119.
HVAC SIZING HVAC Page 11
Project Title Decker Res. Furance Calcs Date. .10/20/11 15:16:35
Project Address
10371 N. BLANEY AVE ******
CUPERTINO, CA 95014 *v8.1*
cumentation AuthorTechnical Analysis D & E ****** Building Permit #
Technical Analysis, Design & Engineering Plan Check / Date
1280 Scott Blvd. , Suite B
Santa Clara, CA 95050
(408) 202-4368 Field Check/ Date
Climate Zone 04
Compliance Method MICROPAS8 v8.1 for 2008 CEC Standards (r03)
I MICROPASB v8.1 File-DECKER Wth-CTZ04S08 I
I User#-MP0580 User-Technical Analysis, Desig Run-Decker Furnace I
GENERAL INFORMATION
Floor Area 1680 sf
Volume 13440 cf
Front Orientation Front Facing 0 deg (N)
Sizing Location CUPERTINO
Latitude 37.3 degrees
Winter Outside Design 28 F
Winter Inside Design 70 F
Summer Outside Design 86 F
Summer Inside Design 75 F
Summer Range 30 F
Interior Shading Used Yes
Exterior Shading Used Yes
Overhang Shading Used Yes
Latent Load Fraction 0.14
HEATING AND COOLING LOAD SUMMARY
Heating Cooling
Description (Btu/hr) (Btu/hr)
Opaque Conduction and Solar 13619 3921
Glazing Conduction and Solar 5542 2339
Infiltration 5842 773
Internal Gain n/a 2520
Ducts 6063 1556
Sensible Load 31065 11109
Latent Load n/a 1622
Minimum Total Load 31065 12731
Note: The loads shown are only one of the criteria affecting the selection
of HVAC equipment. Other relevant design factors such as air flow
requirements, outside air, outdoor design temperatures, coil sizing,
availability of equipment, oversizing safety margin, etc., must also be
considered. It is the HVAC designer's responsibility to consider all
factors when selecting the HVAC equipment.
\ / Building Department
City Of Cupertino
10300 Torre Avenue
41ass Cupertino, CA 95014-3255
Telephone: 408-777-3228
CUPERTINO Fax: 408-777-3333
CONTRACTOR/ SUBCONTRACTOR LIST
JOB ADDRESS: I031 11. of C , ,,10 telt' PERMIT# /6 0
OWNER'S NAME: � ( �cP PHONE# -7 6 4 41
GENERAL
GENERAL CONTRACTOR: A) A BUSINESS LICENSE#
ADDRESS: CITY/ZIPCODE:
*Our municipal code requires all businesses working in the city to have a City of Cupertino business license.
NO BUILDING FINAL OR FINAL OCCUPANCY Imo► SP CTION(S) WILL BE SCHEDULED UNTIL THE
GENERAL CONTRACTOR AND ALL SUBCO N' ORS HAVE OBTAINED A CITY OF CUPERTINO
BUSINESS LICENSE. / /-1/
�`
I am not using any subcontractors:
Signature Date
Please check applicable subcontractors and complete the following information:
V SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE #
Cabinets & Millwork
Cement Finishing
Electrical
Excavation
Fencing _
Flooring / Carpeting
Linoleum /Wood
Glass / Glazing
Heating n R►hls w1
5-1 NZkaittekib
ci lfl 1 ad
Insulation 'i50 to Lig-JO-WY
Landscaping
Lathing
Masonry
Painting /Wallpaper
Paving
Plastering _
Plumbing
Roofing
Septic Tank
Sheet Metal
Sheet Rock
Tile
/1#)///
64der/Contractor Signature Date