13040098 . CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 1134 KENTWOOD AVE CONTRACTOR:SOLARCITY PERMIT NO: 13040098 OWNER'S NAME: MAJID TEHRANI 3055 CLEARVIEW WAY DATE ISSUED:04/11/2013 OWNER'S PHONE: 4082529224 SAN MATEO,CA 94402 PHONE NO:(650)638-1028 LICENSED9.: 1 r / CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL❑ COMMERCIAL❑ icen e Class Gt b Lia# 1iCS7� 4.t 6 INSTALL PV SYSTEM TO ROOFTOP 15 PANELS,3.675 KW, SERVICE UPGRADE 100 AMP Contractor Ot 6,,, �i Date LI - I I r 3 I hereby affirm that I am licens d under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$16000 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance ofthe work for which this APN Number:35931055.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIIN 180 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS FROM LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the Issued b 4�/W ! / " % !f'�V//3 granting of this permit.JAddit e.. ly,the applicant understands and will comply y: Date: with all non-poigt.sotirce regulatis s ger the Cupertino Municipal,Code,Section 9.18. --'=---- .. _ ff 00011111p RE-ROOFS: Si eau c Date I I All roofs shall be inspected prior to any roofing material being installed.If a roof is 7 Alaimo."'" . . installed without first obtaining an inspection,I agree to remove all new materials for inspection. 0 OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property;am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Munici i al Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety CoslerSfeiiiiii 2 1,16. ,a i d 25 4. { i.iiiimet Section 3700 of the Labor Code,for the performance of the work for which this f/./ Owner or authorized agen: '�� I a e: I permit is issued. h .00,-- I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked, work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name .. APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date N\ /,' ALTERNATIVE ENERGY PERMIT APPLICATION...v, COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION V `O 441.r9se 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 (408)777-3228•FAX(408)777-3333•buildinq(a.cupertino.orq \ CUPERTINO 1\11411 ra'1 I PROJECT ADDRESS l J ( / Xizi j jevti APN it 'Z ST-of` 3 /_ D OWNER NAME � / F PH• P fp E-MAIL / ' Cc / sl . 7 0 i , —_ 2-12Z e Le Zr, i'1144,4:(11 STREET ADDRESS 1 /3 ./ /464 ,� C TA� � / /;� / FAX C(a1M 4,14„,,,,t, i 7 r / J / //L1�CONTACT NAME w se) `, .,./�`l /( PHO EMAIL STREET ADDRESS se) �/�/(� + IV/CITY,STATE, ZIP I FAX ❑ OWNER 0 OWNER-BUILDER 0.OWNER AGENT CONTRACTOR 0 CONTRACTOR AGENT 0 ARCHITECT 0 ENGINEER 0 DEVELOPER 0 TENANT CONTRACTOR NAME) K•l az' in aV �kLICENSE ICENSE NUMBER / y LICENSE TYPE` 6 BUS.Lt r /i/ 7z COMPANY NAME ia�r�C � E �. cov��c@s6f �,fyAX65V_'Z'�� STREET ADDCS I9S/�/ 11 /✓ V/` rCI YZE " C�4am! i f 'y17/D y —/z?J.1✓ 7, ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC H COMPANY NAME EMAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF "SFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: 0 Commercial URBAN INTERFACE AREA 0 Yes 0 No FLOOD ZONE ElYes CI NO SOLAR PANELS 0 ELECTRIC VEHICLE CHARGING STATION l 0 SOLAR WATER HEATING 0 O±HER. FdR SOLAR PANELS: NUMBER OF PANELS/UNITS: KILOWATTS(CGM ' ` C 67.5.ik TOTAL VALUATION DESCRIPTION OF WORK ® ch...,_ ws - . , 1S I s- Y d -?-/ wJr✓ vrI jed S /a-4r Com/' vl . . / /. . - RECEIVEDB! - - _. By my signature below,I certify to each of the following: I the pro,erty owner or au horized agent to act on the pro.erty er's behalf. I have read this application and the information I have p ovid • s correct. I ,1.ve read e Descripti_n., Work and verify it is accurate. I ay to comply with all applicable local ordinances and state laws relating to bJ'd' :�structitgt. I uthoriz_/ep esentative .f upertino to enter the abo e.dent ted property for inspection purposes. Signature of Applicant/Agent: �/IL4 d i- 4 L _ Date: S ;I•LEMENTAL ' Ft RMATION REQUIRED • OF&ICE USK9 LY . a OVER 111E-COUNTER ' .F 0' EXPRESS. ' '0 'STANDARD-.. ' :1 d,.LARGE - - :❑. MAJOR - .. PVApp_2011.doc revised 03/16/11 CITY OF CUPERTINO FEE ESTIMATOR-BUILDING DIVISION ADDRESS: DATE: REVIEWED BY: APN: BP#: *VALUATION: $16,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration/ Repair PRIMARY PENTAMATION SFD or Duplex SOLAR-RES USE: PERMIT TYPE: WORK install pv system to rooftop 15 panels, service upgrade 100 amp SCOPE 1 tech.Plan Check 111 Plumb.Plan Check Elec.Plan Check Lai hrs $0.00 Mech. Permit Fee: Plumb.Permit Fee: Elec.Permit Fee: 1EPERMIT Other R1ech.Insp. Other Plumb Insp. Other Elec.Insp. 17,71 hrs $45.00 Mech.Insp.Fee: Plumb. Imp.Fee: Elec.Insp.Fee: NOTE:This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc.). These fees,are based on the preliminary information available and are only an estimate. Contact the Dept for addn'l info. FEE ITEMS (Fee Resolution 11-053 Eff 7/1/12) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 I 1 I # Alternative Energy System Suppl.PC Fee: 0 Reg. 0 OT 0.0 hrs $0.00 $219.00 1PHOTOVRES Photovoltaic System PME Plan Check: $0.00 I 100 I amps Electrical Permit Fee: $0.00 $45.00 1BELEC200 Services Suppl. Insp.Fee:0 Reg. 0 OT (10 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $45.00 Construction Tina:: Administrative Fee: IADMIN $42.00 Work Without Permit? 0 Yes 0 No $0.00 0 Advanced Planning Fee: $0.00 Select a Non-Residential 0 Travel Documentation Fee: 1TRAVvoC $45.00 Building or Structure0 A Strong Motion Fee: 1BSEISMICR $1.60 Select an Administrative Item Bldg Stds Commission Fee: 1BCBSC $1.00 $134.60 $264.00 �i , A $398.60 Revised: 04/01/2013 / Building Department City Of Cupertino 1,IP 10300 Torre Avenue �S -c.19,s Cupertino,CA 95014-3255 Telephone: 408-777-3228 CUPERTINO Fax: 408-777-3333 CONTRACTOR/SUBCONTRACTOR LIST JOB ADDRESS: 113 ( .1- vz / r PERMIT## ` d OWNER'S NAME: „if/1 `i D s 5,-/ / PHONE# (tQe--ZSR—j7..Z `" GENERAL CONTRACT : ,,y—e_ BUSINESS LICENSE# ! `� /. ADDRESS: 3? 6 �( r CITYlapcoDE: ) -6/-c71,4gyve/ *Our municipal code requires all busi sses working in the city to have a City of Cupertino busines license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BY S€HEDULED UNTIL THE GENERAL CONTRACTOR AND ALL UB ONT',, CTI I'S HAVEPRTAINED A CITY OF CUPERTINO BUSINESS LICENSE. . ' I am not using any subcontractors: , i Si ature Date Please check applicable subcontractors and comp ete the following information .: I/ SUBCONTRACTOR BUSINESS NAMEBUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring/Carpeting Linoleum/Wood Glass/Glazing Heating Insulation Landscaping Lathing Masonry Painting/Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile j c / ^fr 46412I-1 i i 40 , Owned,ontractor Signature Date ABBREVIATIONS ELECTRICAL NOTES INDEX LICENSE JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING PV1 COVER SHEET CA # 888104 FLASHING WILL BE PAINTED TO MATCH MEANS MAY BE ENERGIZED IN THE OPEN PV2 SITE PLAN C-46, C-10 AC ALTERNATING CURRENT PV3 STRUCTURAL VIEWS EXTERIOR BLDG BUILDING POSITION, A SIGN WILL BE PROVIDED WARNING ate, _ OF THE HAZARDS PER ART. 690.17. PV4 UPLIFT CALCULATIONS 9 W t`'' ` I- -' !I CONC CONCRETE PV5 THREE LINE DIAGRAM r 1 rl ,, '' - Installing 15-rooftop flush-mounted panels(3.675 C COMBINER BOX 2. EACH UNGROUNDED CONDUCTOR OF THE PR j kW), Upgrade100-Amps BRANCH CIRCUIT WILL BE IDENTIFIED PV6 ELECTRICAL CALCULATIONS ;,l �,., 2013 Elect Srvice to 100 Am s D DISTRIBUTION PANEL PV7 ELEC. LOAD CALCULATIONS DC DIRECT CURRENT BY PHASE AND SYSTEM PER ART. 210.5. APN: 359-31-055 EGC EQUIPMENT GROUNDING CONDUCTOR 3. A NATIONALLY-RECOGNIZED TESTING CUTSHEETS ATTACHED - (E) EXISTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. COMMUNnYD i •;.,, ./ . . . ,i, lashingwill be painted to EMT ELECTRICAL METALLIC TUBING 4. CIRCUITS OVER 250V TO GROUND SHALL GALV GALVANIZED G SOLAR RD METER COMPLY WITH ART. 250.97, 250.92(B) :11 USING DMSlON -CUPERTINO match exterior. GEC GROUNDING ELECTRODE CONDUCTOR 5. DC CONDUCTORS EITHER DO NOT ENTER APPROVED BUILDING OR ARE RUN IN METALLIC RACEWAYS GENERAL NOTES specifications MUST be kept at GND GROUND This set of plans and HDG HOT DIPPED GALVANIZED OR ENCLOSURES TO THE FIRST ACCESSIBLE DC job site during construction. It is unlawful to make : stalling 15 roof top flush I CURRENT DISCONNECTING MEANS PER ART. 690.31(E). than Imp CURRENT AT MAX POWER 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN 1. THIS SYSTEM IS GRID-INTERTIED VIA A ges or alterations on same, or to deviate mounted panels (3.675 kW) INVS INVERTERS RELIEF AT ALL ENTRY INTO BOXES AS UL-LISTED POWER-CONDITIONING INVERTER. therefrom, without approval from the Building Official. Isc SHORT CIRCUIT CURRENT REQUIRED BY UL LISTING. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. The Stamping of this plan and specifications SHALL Nii Ql kVA KILOVOLT AMPERE 7. MODULE FRAMES SHALL BE GROUNDED AT THE 3. PHOTOVOLTAIC SOURCE AND INPUT CIRCUITS AND he held to Upgrade Electrical service to U kW KILOWATT UL-LISTED LOCATION PROVIDED BY THE INVERTER INPUT CIRCUIT ARE UNGROUNDED. permit or to be an approval of the violati I n pg (� LBW LOAD BEARING WALL MANUFACTURER USING UL LISTED GROUNDING 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED of any provisions of any City Ordinance or State La .100 Amps v �, MIN MINIMUM HARDWARE. 5. ALL WORK TO BE DONE TO 2010 CALIFORNIA BY I79,v 4,,,i-7.- MIR , G �\ BUILDING CODE. 4 CUPERTINO MIR MIRROR 8. ALL EXPOSED METAL PARTS (MODULE FRAMES, DATE /-/� ./ 3 ,�.��� N 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE ( ) NEW RAIL, BOXES, ETC.) SHALL BE GROUNDED USING PERMIT Ai0 / Gp NEC NATIONAL ELECTRIC CODE UL LISTED LAY-IN LUGS LISTED FOR THE 2008 NATIONAL ELECTRIC CODE AS AMENDED BY Building Department \ NIC NOT IN CONTRACT PURPOSE. POSTS SHALL BE MADE THE 2010 CALIFORNIA ELECTRIC CODE. `) NTS NOT TO SCALE ELECTRICALLY CONTINUOUS WITH ATTACHED I -, APR 1 2013 v OC ON CENTER RAIL. O P PANEL BOARD 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE E IEWED FOR CODE COMPLIANCE N. PL PROPERTY LINES BONDED WITH EQUIPMENT GROUND CONDUCTORS / PV PHOTOVOLTAIC AND GROUNDED AT THE MAIN ELECTRIC PANEL. r�eviewe0 By ,� � /1'7 ti`l PVC POLYVINYL CHLORIDE 10. THE DC GROUNDING ELECTRODE CONDUCTOR VICINITY MAP S SUBPANEL SHALL BE SIZED ACCORDING TO ART. SCH SCHEDULE 250.166(B) & 690.47. lam,, •.`• 4" "'� tJ % ''' , .. SS STAINLESS STEEL ,`! ' '; " �, ,a."Tlptoe'L11""� ``� "at & �* SSD SEE STRUCTURAL DRAWINGS ,�„F ` 7 4)f "0.4'`x"`• I '�”' .; , ,IT PLAINS ',- A • 114 STC STANDARD TESTING CONDITIONS ss: .•• ; 1 ,. • ', - : -et* ' '� '�` — , SWH SOLAR WATER HEATER ' .� —Stanford'P1 • fiII t! . �[,�v TYP TYPICAL n ` `. .. - , 0,; + - !!... R flit ice r . . 1 f: 13 it ii UON UNLESS OTHERWISE NOTED Wr14.11 Ln ' d f • �t` `mss 'i'M' i' D 1 A , UPS UNINTERRUPTIBLE POWER SUPPLY it. " ' . '' '�� ' l C` ° G /� V VOLT � ,'i�'I`` ' 4.' 4'� `:,�' .D�/la•`/ICO t PLANNING DEPT. VmpVOLTAGE AT MAX POWER Y r "' /�' ' � r ` ti ' 'p m . Cn r-` , ,' w. •y ,rr,.Lip'' .',' ' .'•t'a" '. w'" t 4 i.. , DATE W VOLTAGE AT OPEN CIRCUIT am::. torr e r w 10 , ' t, ', to le W WATTFAir ,� •> ,CS ,0� �i 3R NEMA 3R, RAIN11GHT � .. :` " ,_ •�. Co�- �y . I - rig ..;,74,-1;_,S;0., , - '. ------------- BLDG. DEPT'- . _ - '' -0,0-03 - ; H011 nderry;��! 0:464\ ` • ,; 7:4, ,,,"" i 1 1 r REV BY DATE COMMENTS 4"— _. . : `%' * 'O/, 4', 61-.71.4“,,,' r K'... Q T 11,2 ---,,' * _ , . A 9,;,, sm. '.. i '®®4/6/2013 COMMENTS E ''• �T/ - Ing i.-,-,r 'pietyt,i,,,,, , z... e c., _ fe , •e lf:— 10; FirsTPW :2 II itk ; k‘-'4.14- .21.z..et ' ' r©©© + CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J 8-9501596 0 0 PREMISE OWNER: AHJ: Cupertino DESCRIPTION: DESIGN: ,�.�r„I CONTAINED SHALL NOT BE USED FOR THE MOSTOFI MAJID MOSTOFI RESIDENCE MWALK ..- BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: re I NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 1134 KENTWOOD AVE 3.675 KW PV Array /qi, SOla ity PART TO OTHERS OUTSIDE THE RECIPIENTS REST 15 TRINA SOLAR ; TSM-245PC05 PA05.1: o /Ping' ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: MOUNTING SYSTEM. CUPERTINO, C A 9 5014 FITT_ 3055 gearview Way San Mateo,CA THE SALE AND USE OF THE RESPECTIVE Com. Mount TAse C with Lifter 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: IN LER: PAGE NAME: SHEET: REV DAZE: T:(650)636-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. PPA (1) POWER-ONE # AURORA PVI-3.0-OUTD S-US (408) 252-9224 COVER SHEET PV 1 4/6/2013 (888)-SOL-CITY(765-2409)www.sdarcity.com *nc'2, ,`` ,, r, ; ,, , PITCH: 19 ARRAY PITCH:19 A � MP1 AZIMUTH: 134 ARRAY AZIMUTH: 134 IA .ti, 1 �`'"; ', , 4 MATERIAL: Comp Shingle STORY: Above Tw 1 Stories.,. ,"' fia, , - , , r. A4:• * ,,,/ , •', •a''a ,,.,.k. '.t ,....%. • W .- ... J g,-- • YL+ RTINO st,N. ..- ( z,.../ ,, „. ', s \� 'kl, ' Jf, , . > -„ Building Department • : �; ` ,. 4111111W \ �W APR 1 1 2013 t ,.s ,`c „ ,,.- . , ` `L\ EV ED FOR CODE COMPLIANCE C �" bl‘ti 'I. ' '-7t✓YI@1df�-Cj f3V �fi9J./ ���7 :k T � //l '' �t..i7'0 WIVI')O' W.— MI 1 �' �' � . LEGEND ! Ar.QD , „_,..•e 1, j - r i•gical$ r V 1NrAirik25 to PL .'pp , ® (E) UTILITY METER & WARNING LABEL i 411111111 ® INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS 1134 Kentwood Ave VDC H DC DISCONNECT & WARNING LABELS b I= AC DISCONNECT & WARNING LABELS –––— - 30'to PL Total roof area is 2121 sq ft. JUNCTION BOX Total array area is 270 sq ft. 12%coverage. O DC COMBINER BOX & WARNING Front Of House 0 DISTRIBUTION PANEL & WARNING c Ps1MP13 F ire Setbak I Lc LOAD CENTER & WARNING LABELS 7 uEll .• M DEDICATED PV SYSTEM METER / FLASHING WILL BE O 46% PAINTED TO MATCH CONDUIT RUN ON EXTERIOR ,-5`` ' EXTERIOR CONDUIT RUN ON INTERIOR GATE/FENCE ���' o --- INTERIOR EQUIPMENT / �� 1 — Z ® 0 SITE PLAN 4, -7 5'to PL 401 pc) Scale: 3/32" = 1' fro a 01' 10' 21' s F . . CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER JB-9501596 0 0 PREMISE OWNER AHJ: Cupertino DESCRIPTION: DESIGN: `ta`/dam CONTAINED SHALL NOT BE USED FOR THE MOSTOFI, MAJID MOSTOFI RESIDENCE MWALK �; �, BENEFIT OF ANYONE EXCEPT SOLARCITYHOLE INC., MARKET: MODULES: 'I, So1arC�ty NOR SHALL IT BE DISCLOSED IN WHOLE OR IN REST (15) TRINA SOLAR TSM-245PC05/PA05.18 1134 KENTWOOD AVE 3.675 KW PV Array /`` o PART TO OTHERS OUTSIDE THE RECIPIENTS PROJECT MANAGER: MOUNTING SYSTEM: C U P E R TI N O, C A 9 5014 J�"� W ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clearview Way San Mateo,CA THE SALE AND USE OF THE RESPECTIVE Comp Mount Type C with Lifter 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE T:(650)638-1028 F:(650)638-1029 PAYMENT TYPE: INVERTER: PERMISSION OF SOLARCITY INC. PPA (1) POWER—ONE # AURORA PVI-3.0—OUTD—S—US (408) 252-9224 SITE PLAN PV 2 4/6/2013 (BBB)—SO—CITY(ass lass)www.aolarclty.com Module is 6 inches off / 4' f, rooface f (E) 2 4 RAFTER sur ® 24" O.C. (E)RID 2x6 1 1f T I 1111111P RIDGE BOARD k 1 T i °ral 00000 ' (E) 2x4 N i A N k iO ! F 2' i (E) 2x4 RAFTERS 0 24" SPACING A'-6 5'-11" 2'-11" 4'-6" (E) 2x6 CEILING -,t` (E) LBW - (E) LBW M (E) LBW JOIST ® 16" O.C. FRONT VIEW OF MP1 RAFTER: 2x4 B SUPPORT: 2x4, 2x6 SCALE: 1/2" = 1' MAX SPAN: 5'-11" SIDE VIEW OF MP1 SCALE: 1/4" = 1' PV MODULE 5/16" BOLT WITH LOCK & FENDER WASHERS (6) INSTALLATION ORDER ZEP LEVELING FOOT LOCATE RAFTER, MARK HOLE (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT n ,, .� * � HOLE. At (4) @SEAL PILOT HOLE WITH ZEP COMP MOUNT C II POLYURETHANE SEALANT. ZEP FLASHING C (3) (3) INSERT FLASHING: I(E) COMP. SHINGLE v ; � C PLACE MOUNT. lItrilding DeAartment ' ® Ian' (E) ROOF DECKING (5) INSTALL LAG BOLT WITH � , 5/16" DIA LAG BOLT (5) SEALING WASHER. ¢•-y j A12 �3 WITH SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH iq,E i -, �trJ_C> rCf? CODE COMPLIANCE (2-1/2" EMBED, MIN) (6) BOLT & WASHERS. I`c`vie`yyec7 By J /` (E) RAFTERel STANDOFF Scale: 1 1/2" = 1' CCNFlDENTAL— THE INFORMATION HEREIN JOB NUMBER JB-9501596 00 PREMISE OWNER: AH,: Cupertino DESCRIPTION: MW: mita kV CONTAINED SHALL NOT BE USED FOR THE MOSTOFI, MAJID MOSTOFI RESIDENCE NOR SH OF ANYONE EXCEPT SOLWHOLE RAC., MARKET: MODULES �j��`SoiarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN REST (15) TRINA SOLAR # TSM-245PCO5/PA05.18 1134 KENTWOOD AVE 3.675 KW PV Array jj����� PART TO OTHERS OUTSIDE THE RECIPIENTS PROJECT MANAGER MOUNTING SYSTEM: CUPERTINO, CA 95014 fl►r ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 CleanAew Way Son Mateo,CA TIHE SALE AND USE OF THE RESPECTIVE Comp Mount Type C with Lifter 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN .PAYMENT TYPE IN TIR: PAGE NAME SHEET: REV: DATE T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARgTY INC. PPA 1� POWER-ONE # AURORA PVI-3.0-OUTD-S-US (408) 252-9224 STRUCTURAL VIEWS PV 3 4/6/2013 (&38)—SOL—CITY(765-2489) .�Ia�Ry. , UPLIFT CALCULATIONS 04.06.2013 Version#9.4 SOlarCitY Wind Uplift Calculator Project Information Risk Category II PV System Type SolarCity SleekMountr" Comp Roof Comp Roof #Layers(Comp Roof Only) 1 Roof Slope 19° Rafter Spacing 24"O.C. PV Module Orientation Landscape Total Area of Array 264 sf PV Module Width 3.3 ft PV Module Length 5.4 ft Attachment Type Comp Mount Type C with Lifter Ground/Roof Snow Loads Ground Snow Load pq 0.0 psf • ASCE Table 7-1 Roof Snow Over PV Modules ps-pv 0.0 psf Surrounding Roof Snow ps-roof 0.0 psf Wind Design Criteria Wind Design Code 0 ASCE 7-05 Wind Design Method 0 Partially/Fully Enclosed Method Basic Wind Speed V 85 mph • Fig.6-1 Exposure Category 0 C ' Section 6.5.6.3 Roof Style 0 Gable Roof 'Fig.6-11B,C/D-14A1B Mean Roof Height h 0 ft Section 6.2 Least Horiz.Dim.of Building LHD 0 ft Effective Wind Area(1 Module) A 17.6 sf IBC 1509.7.1 Roof Wind Zone Width a 3 ft Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.85 Section 6-3 Topographic Factor Kzt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Section 6-4 Importance Factor 1 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 13.3 psf Wind Zone Interior(Zone 1) Edge(Zone 2) Corner(Zone 3) Ext.Pressure Coefficient(Up) GCp(Up) -0.9 -1.6 -2.5 Fig.6-113C/D-14AjB Ext.Pressure Coefficient(Down) GCp(Down) 0.5 0.5 0.5 Fig.6-11B/C/D-14A/B Design Wind Pressure p p= qh(GCp) Equation 6-22 - Wind Pressure Up p(up) -11.7 psf -21.0 psf -32.7 psf Wind Pressure Down p(down) 10.0 psf 10.0 psf 10.0 psf Comp Allowable Attachment Spacing (In.) And Tributary Area (Ft^2) Interior(Zone 1) Edge(Zone 2) Corner(Zone 3) ' C U P E R Ti N O Max Allowed Foot X-Spacing Landscape 48" 48" 48" L-4121:1:71"1.11:s- l ails 19 Department Max Allowed X Cantilever Landscape 24" 24" 24" 3 1 Max Standoff Tributary Area TribCL 13 sf 13 sf 13 sfePV Assembly Dead Load WPV 3 psf 3 psf 3 psfjy DLPV PCL 39 lbs 39 lbs 39 lbs WLUP-0.6 DLPVcos(B) TCL -152 lbs -274 lbs -426 lbs REVIEWED FOR CODE COMPI Attachment Uplift Capacity Tallow 637 lbs 637 lbs 637 lbs Ir��CE TCL/Tallow DCRLand 23.9% 43.0% 66.9% Reviewed By , 7,.,r //4.,,v7" CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J 3-9 501 596 0 0 PREMISE OWNER: AHJ: Cupertino DESCRIPTION: DESIGN: `*k14' CONTAINED SHALL NOT BE USED FOR THE MOSTOFI, MAJID MOSTOFI RESIDENCE MWALK �- ��SolarCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN 1134 KENTWOOD AVE 3.675 KW PV Array • PART TO OTHERS OUTSIDE THE RECIPIENTS RESI (15) TRINA SOLAR TSM-245PC05/PA05.18 /� -/ 0 /./ e/ ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: MOUNTING SYSTEM: CUPERTINO, CA 95014f,� r/VQ,�Q1 3055 Clearvew Way San Mateo, CA THE SALE AND USE OF THE RESPECTIVE Comp Mount Type C with Lifter 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN • PAGE NAME: SHEET: REV: DATE: PERMISSION OF SOLARCITY INC. PAYMENT TYPE: INVERTER: (408) 252-9224 PV 4 4/612013 (888)-SOL-CITYT:(650)638-1028 F:(650)638-1029 PPA (1) POWER-ONE # AURORA PVI-3.0-OUTD-S-US UPLIFT CALCULATIONS (765-2489)www.solorciiy.°°m GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) GROUND ROD N 100A MAIN SERVICE PANEL Inv 1: DC Ungrounded INV 1—(')l r;3300TIOW.240V,96X 30-01"D-s'US A —('5)T A SOLAR A 2I� isPV Block222.9W PTC,40N11, r,,,,. CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP (N; 100A/2P MAIN CIRCUIT BREAKERVoc: 37.3 C-46, C-10 Panel Number:no INV 2 Vpmax:30.7 Meter Number:1005220907 *MODULE CURRENT RATINGS ARE SHOWN AS Isc AND Imp IN Overhead Service Entrance INV 3 THE DC STRINGS IDENTIFIER OF THE SINGLE LINE DIAGRAM. MAIN SERVICE PANEL ADJUST MIN. ACTIVATION VOLTAGES! Inverter 1 IND 100A/2P ® POWER–ONE AURORA PVI-3.0–OUTD–S–US Q pc.SET MI .ACTIVATION VOLTAGE TO 1 .13V EGC 1 String(s)Of 7 On MP 1 d� (E) LOADS __,. / J EMI �. 1 L1 I— V L2 I GFP/GFCI�/ DC+ I (N)20A/2P EGC/N —�_ DC+ I 2 �+DC- DO NOT ADJUST MIN.ACTIVATION V9LTAGE ID m __„_�� q J GEC O �_ DC_I 1 String(s)Of 8 On MP 1 %�B 1 I i GND I___ EGC 11-- EG( J (1)Conduit KH;3/4'ENT N EGC/GEC l v J z-z c� GEC 1 TO 120/240V I SINGLE PHASE I UTILITY SERVICE I II I . fir!! CUPERTINO BUII I d ng Department APR 1 1 2013 ACDC REVIEWED FOR CODE COMPLIANCE _ Reviewed By J "/ /7 OW(1)AWG p0.hall-2,Black ^ —(2)A p0.Pv IRE,Bock Voc =261.1 VDC Isc =8.47 ADC (1)AWG fitTNwx—z,Red (, j ) —(1)ANN is,sola an copper ECC Vmp =214.9 VDC Imp=7.98 ADC (1)AWG p0,1111W1-2.1M%He NEUTRAL Vmp =240 VAC Imp=14.5 MC v (1)CaduR KN 3/4'BIT —(1)AWG 18,TH1N-2,Green EGC/GEC —(1)Backlit KH;3/4'ENT O ((21))AAWG WG pre0,SPhVcd YItE Bo,n Block er EGC VVOmCp =248VVDDCC IISCmp==8478 AADDCC (1)Conduit Kit;3/4'EMT CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER J B-9501596 00 PREMISE OWNER AHJ: Cupertino DESCRIPTION: DESIGN: `��/dam CONTAINED SHALL NOT BE USED FOR THEMWALK �� ■ BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES MOSTOFI, MAJID MOSTOFI RESIDENCE NOR SHALL IT BE DISCLOSED IN WHOLE CR IN RESI (15) TRINA SOLAR # TSM-245PC05/PA05.1$ 1134 KENTWOOD AVE 3.675 KW PV Array .�',s�'arCi EN ORGANIZATION, EXCEPT IN C• PART TO OTHERS OUTSIDE ONNEECC1 ON YOH PROJECT MANAGER: MOUN11NG SYSTEM: CUPERTINO, CA 95014 OW 3055 Cleorview Way San Mateo.CA THE SALE AND USE OF THE RESPECTIVE Comp Mount Type C with Lifter 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE IN TER PAGENAME: SHEET: REV: DATE: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. (408) 252-9224 PPA (1) POWER-ONE # AURORA PVI-3.0-OUTD-S-USTHREE LINE DIAGRAM PV 5 4/6/2013 (888)-SOL-CITY -2489)www.solacRycom 1. Conductor Sizing per Art 690.8(A) ELECTRICAL CALCULATIONS • a. Conductor must have 30 deg. C ampacity >= 125% of continuous .iiii �/ current. Module: 15 TRINA SOLAR#TSM-245PC05 222.9 Inv Power WPTC Voltage Drop Calculations Version 5_8.0 Jake Tornatzky '- Inverter Inverter 1: 1 Power-One PVI-3.0-S 0.96 3480 3209.76 Vdrop= Imp) * (2*Length)*(Resistance) / mp) b. Conductor must have (after corrections for conditions of use) >= Module: Imp(A) Max.Length(ft) Wire _ continuous current per Table 310.15(B)(16). Inverter 2: String: 7.98 70 AWG_10_ at Max Ave Hi:82 deg F Module: Vdrop= (7.98 *140 *0.0 1240hms) / 223.712 0.71 Inverter 3: Branch: 17.98 I 0 I AWG_10_ at Max Ave Hi:82 deg F c. Evaluate conductor temperature at terminations per 110.14(C). Vdrop= (7.98 *0 *0.00124Ohms) / 223.712 0 Ampacity of wire derated for conditions of termination must be >= Module: Total voltage drop in DC conductors= 0.71 continuous current*1.25. All string terminations are rated at 90' C. Inverter 4: Inverter: 17.98 I 10 I AWG_10 I at 240V Vdrop= (7.98 *20 *0.0012 Ohms) / 240 V 0.0798 Total: 15 Modules Total Inv Pwr: 3480 3209.76 PTC Combined 0 I 0 I 1 at 240V 2. OCP Sizing per Art 690.8(6)(1) Photovoltaic Module Electrical Specifications: Total STC: 3675 Vdrop= (0 *0 Ohms) / 240 V 0 a. Round up to next size per Art 240.4(6) Voc: 37.3 V deg F deg C 3. Conductor Sizing per Art 690.8(A) Vmp: 30.7 V Record Low Temp: 32 0 Total voltage drop in AC conductors= 0.08 a. Conductor must have 30 deg. acct >= 125% of continuous Isc: 8.47 A Max Average Hi Temp: 82 28 Total voltage drop in AC and DC conductors= 0.79 g ampacity Imp: 7.98 A Record Hi Temp: 89 32 current. Tvoc: -0.11532 V/deg C Tisc: 4.185 mA/deg C I b. Conductor must have (after corrections for conditions of use) >= String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc data Branch Circuit Type A 1 way wire length: 0 continuous current per Table 310.15(6)(16). Power-One PVI-3.0-S Voc Correction Factor: 1 strings per branch 1 1 strings per branch 2 Inverter Min Vdc Input: 120 8 TRINA SOLAR#TSM1245PC05 8 modules per series string 7 modules per series string c. Evaluate conductor temperature at terminations per Art 110.14(C). Voc= 298.4 Min Vmp at Max Temp: 223.71 Voc= 298.4 V Voc= 261.1 V Ampacity of wire derated for conditions of termination must be >= Vmp= 245.6 Max Voc at Min Temp: 321.46 Vmp= 245.6 V Vmp= 214.9 V continuous current*1.25. All branch terminations are rated at 75' C Isc= 8.47 Inverter Max Vdc Input: 600 Isc= 8.47 A Isc= 8.47 A min. Imp= 7.98 Max String Size: 14 Imp= 7.98 A Imp= 7.98 A !cont.= 10.59 Art 690.8(A)(1) 1-way wire length: 70 Icont= 10.59 A (cont= 10.59 A Art 690.8(A)(1) 4. OCP Sizing 1.a Conductor: AWG_10 PV Wire 2.a Conductor 1: AWG_10 PV Wire a. Round up to next size per Art 240.4(6) Conductor 2: AWG_10 PV Wire (cont*1.25=(Amps) 13.23 Conductor 1 Conductor 2 5. Conductor Sizing per Art 690.8(A) 30 deg C ampacity= 40 Icont*1.25=(Amps) 13.23 13.23 a. Conductor must have 30 deg. C ampacity >= 125% of continuous 1.b Icont=(Amps) 10.59 30 deg C ampacity= 40 40 I Start ampacity 40 2.b Icont=(Amps) 10.59 10.59 current. Temperature derate(%=F) 0.71 Start ampacity 40 40 Conduit fill derate(%=#) 1 Temperature derate(%=F) 0.82 0.82 ApR b. Conductor must have (after corrections for conditions of use) >= Derated ampacity 28.4 Conduit fill derate(%_#) 0.8 0.8 continuous current per Table 310.15(6)(16). 1.c Derated ampacity 26.24 26,24.i �^c Icont*1.25=(Amps) 13.23 2.c Term 1 Term CUPERTINO c. Evaluate conductor temperature at terminationsper Art 110.14(C). Ampacity 40 1 Temp table 75d �C 75degC i iaiit ifl p Icont*1.25=(Amps) 13.23 'k..„i r6t6�1@11t Ampacity of wire derated for conditions of termination must be >= 1.d Icont*1.25=(Amps) 13.23 continuous current*1.25. All inverter output terminations are rated at OCP Size= 15< Ampacity 35 �- 1 2013 75' C. Inverter Type A Output 2.d OCP Size= 15 1 15 1 6. OCP Sizin Power-One PVI-3.0-S = 1 way wire length: 10 ft Combined Inverter Output -�.E�'�-E� Ft3F� CODE COhnPLIANCE Sizing Icont= 1 14.5 I A Art 690.8(A)(1) Service Voltage= a. Round up to next size per Art 240.4(6) 3.a Icont*1.25=(Amps) 18.12 Art 690.8(B)(1) Total Inverter Power= 1 Vim' 'lig rY ut',./ /-7/A7- OCP Size= 20 Art 240.6(A) Icont=#of inverters*max inverter current Art 690.8(A)(1) 7. Conductor Sizing per Art 690.8(A) 3.b Conductor:)AWG_10 THWN-2 at 90 deg C:Table 310.16 Icont=(Amps) a. Conductor must have 30 deg. C ampacity >= 125% of continuous Icont*1.25=(Amps) 18.12 4.a (cont*1.25=(Amps) Art 690.8(6)(1) Current. 30 deg C ampacity= 40 I OCP size= Art 240.6(A) 3.c Icont=(Amps) 14.5 4.b Conductor: THWN-2 at 90 deg C:Table 310.16 Start ampacity 40 Icont*1.25=(Amps) b. Conductor must have (after corrections for conditions of use) >= 30 deg C ampacity= Temperature derate(%=F) 0.91 continuous current per Table 310.15(6)(16). Conduit fill derate(%=#) 1 4.c Icont=(Amps) Derated ampacity 36.4 Start ampacity c. Evaluate conductor temperature at terminations per Art 110.14(C). 3.d Icont*1.25=(Amps) 18.12 Temperature derate(%=F) Ampacity of wire derated for conditions of termination must be >= Ampacity 35 Conduit fill derate(%=#) continuous current*1.25. All inverter output terminations are rated at Derated ampacity 4.d Icont*1.25=(Amps) 75' C min. I Ampacity CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J B-9501 59 6 0 0 PREMISE OMR AHJ: Cupertino DESCRIPTION: DESIGN: `044 CONTAINED SHALL NOT BE USED FOR THE MOSTOFI, MAJID MOSTOFI RESIDENCE MWALK �� BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES RESI (15) TRINA SOLAR TSM-245PC05/PA0518 3.675 KW PV Arrayn S O'a�I NOR SHALL IT BE DISCLOSED IN WHOLE CR IN 1134 KENTWOOD AVE PART TO OTHERS OUTSIDE THE RECIPIENT'S . /�� ��� ORGANIZATION, EXCEPT IN CONNECTION WITH QCT MANAGER: MOUNTING SYSTEM: CUPERTINO, CA 95014 iW THE SALE AND USE OF THE RESPECTIVE Comp Mount Type C with Lifter 3055 aearview9WWay2San Mateo,CA SOLARCIIY EQUIPMENT, WITHOUT THE WRITTEN PAYMENT TYPE: IN TER (408) 252-9224 PAGE NAME: SHEET: REV D4 6 2013 T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARaTY INC. PPA (1) POWER-ONE # AURORA PVI-3.0-OUTD-S-USELECTRICAL CALCULATIONS PV 6 (888)-SOL-CITY(765-2489)w*w.�larastyaorn NEC 2008 220.82 - Residential Load Calculation Version 2.1 L11L2 240 V NEC 220.82(B) The general calculated load shall be not less than 100% of the first 10 kVA plus 40% of the remainder of the following loads...' NEC 220,82(8)(1) The calculated floor area shall not include open porches, garages, or unused ... spaces .. • Floor Area 2,121 square feet x 3V.Nsq ft 6,353 V.A NEC 220.8293)(2) "1500 volt-amperes for each 2-wire,20-ampere small appliance branch circuit and each laundry branch circuit...• Small Appliance Circuits 8 circuits x 1500V.AIcircuit 12,000 V.A Laundry Circuits circuits x 1500VNcircuit 0 V.A Bathroom Circuits circuits x 1500VAJcircuit 0 VA NEC 220.82(B)(3) The nameplate rating of all appliances__ ranges,wall-mounted ovens, counter-mounted & 220.82(B)(4) cooking units... clothes dryers that are not connected to the laundry branch circuit... [and]water heaters" 2P Breaker VA Oven 40 7,680 Stove 30 5,760i Dryer 30 5,7601 Water Heater 20 3,8401 0 01 0' 04 0 23,040 total ,A Total of non air-conditioning loads. 41,403 total 4.. First 10 kVA of load at 100% 10,000 Remainder of load at 40% 12,561 Adjusted total of non air-conditioning load 22,561 '.'.�. NEC 220.82(C) Heating arn� air-conditiong load .. : PERTINO 2P Breaker 1 VA 1 .� Bla:`dl ig Department Sum of AIC Equipment Units 30 5,7501 Sum of Electric Furnaces p 0 • •• 1 1 2013 Total of ASC Loads and .11 Other Loads 28,321 total VA FOR CODE COMPLIANCE Total Proposed Calculated Load: 118.01 Amps G� ,6.f.. J B - 123456 ►�`'SoiarCitv copyright SolarCit 201 Y CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBERJB-9501596 00 PREWSE OMER: AHJ: Cupertino DESCRIPTION: DESIGN: ` edr MOSTOFI, MAJID MOSTOFI RESIDENCE MWALK CONTAINED SHALL NOT BE USED FOR THE �• � BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: 'I1 S o I a rC i ty NOR SHALL IT BE DISCLOSED IN WHOLE OR IN REST (15) TRINA SOLAR TSM-245PC05/PA05.18 1134 KENTWOOD AVE 3.675 KW PV Array /1; PARTRTOZ OTHERS OUTSIDE THE RECIPIENTS PROJECT MANAGER MOUNTING SYSTEM: CUPERTINO, CA 95014 J�,' 14te\ ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE Comp Mount Type C with Lifter 3055 ClearviewSan Mateo, CA 94402 Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE PERMISSION OF SOLARCITY INC. PAYMENT TYPE: INVERTER: 40H 252-9224 4 6 1:(650)638-1028 F:(650)638-1029 2013 PPA (1) POWER—ONE # AURORA PVI-3.0—OUTD—S—US ELEC. LOAD CALCULATIONS PV 7 (BBs)—sa—CITY(765-24e9)www.solarcit.corn Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT (C) MAXIMUM AC _ WARNING A (AC) (POI) (DC) (INV) Per Code: OPERATING CURRENT Per Code: Per Code: CA Fire Guidelines MAXIMUM AC -V CEC 690.54 ELECTRIC SHOCK HAZARD CEC 690.35(F) OPERATING VOLTAGE THE PHOTOVOLTAIC SYSS MPARES TO BE USED WHEN Label Location: UNGROUNDED AND INVERTER IS PHOTOVOLTAIC DC (DC) (INV) MAYBE ENERGIZED UNGROUNDED DISCONNECT Per Code: CEC 690.14.C.2 Label Location: PV SYSTEM (AC) (P01) DISCONNECT FOR UTILITY OPERATION Label Location: MAXIMUM POWER-_A (DC) (INV) POINT CURRENT(Imp) Per Code: MAXIMUM POWER- v CEC 690.53 POINT VOLTAGE(Vmp) MAXIMUM SYSTEM Label Location: VOLTAGE(Voc) WARNING (AC) (P01) SHORT-CIRCUIT CURRENT(Isc) A ELECTRIC SHOCK HAZARD Per Code: CEC 690.17 DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label Location: WARNING (DC) (CB) Per Code: ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS CEC 690.17 Label Location: TERMINALS ON BOTH LINE AND PHOTOVOLTAIC POINT OF (P01) LOAD SIDES MAY BE ENERGIZED INTERCONNECTION Per Code: IN THE OPEN POSITION WARNING:ELECTRIC SHOCK DC VOLTAGE IS HAZARD.DO NOT TOUCH CEC 690.54; CEC 690.17 ALWAYS PRESENT WHEN TERMINALS.TERMINALS ON SOLAR MODULES ARE BOTH THE LINE AND LOAD SIDE EXPOSED TO SUNLIGHT MAY BE ENERGIZED IN THE OPEN POSITION.FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. wU����I�� PV POWER SOURCE =:� 9 Department MAXIMUM AC :71447..,e.6._ Label Location: A WARNING OPERATING CURRENT `�. J.ap:e(DC) (INV) MAXIMUM AC ` 9Per Code: OPERATING VOLTAGE _ APR ;I�j°3 ELECTRIC SHOCK HAZARD CEC 690.5(C) IFAGROUND FAULT IS INDICATED LtV.I` c NORMALLY GROUNDED ��` D FOR CODE COMPLIANCE CONDUCTORS MAY BE �/ UNGROUNDED AND ENERGIZED Label Location: Reviewed By N 74/#/7-‘,/ CAUTION (D) (POI) Per Code: PHOTOVOLTAIC SYSTEM CEC 690.64.B.4 Label Location: CIRCUIT IS BACKFED PHOTOVOLTAIC AC (AC) (P01) (AC): AC Disconnect Per Code: (C): Conduit DISCONNECT CEC 690.14.C.2 (CB): Combiner Box Label Location: (D): Distribution Panel (DC): DC Disconnect CAUTION (P01) (IC): Interior Run Conduit DUAL POWER SOURCE Per Code: SECOND SOURCE IS CEC 690.64.B.4 (INV): Inverter With Integrated DC Disconnect PHOTOVOLTAIC SYSTEM (LC): Load Center (M): Utility Meter (P01): Point of Interconnection CONFIDENTIAL– THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR -,0e4 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �- San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, SC - CA Label Set 4�'� T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE I/ SolarCity (888)-SOL-CITY(765-2489)www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. • mono multi solutions Trina mount II FOR PITCHED ROOF TSM-PC05/ PA05.18 mono multi solutions ELECTRICAL DATA®STC TSM-225 TSM-230 TSM-235 TSM-240 TSM-245 DIMENSIONS OF PV MODULE TSM- /PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 Peak Power Wathss-Prx(Wp) 225 230 235 240 245 Trtnamountll 10 YEAR - Power Output Tolerance-N.(%) 0/+3 01+3 30.1 0/03 0/+3 Maximum Power Voltage-Vmv(V) 29.4 29.8 30.1 30.4 30.7 PRODUCT WARRANTY FOR MODULE Maximum Power Current-Bop(A) 7.66 7.72 7.81 7.89 7.98 Trinasolar AND MOUNTING SYSTEM E Open Circuit Voltage-Voc(V) 36.9 37.037.1 37.2 37.3 FOR PITCHED ROOF Short Circuit Current-Isc(A) 8.20 8.26 8.31 8.37 8.47 5�/ Module Efficiency ry (%) 13.7 14.1 14.4 14.7 15.0 - FASTER TOINSTALL AL _IA Values at Standard Test ConditionsSTC(Air mass AM1.5.Irradiance 1000W/m',CeUTemperature 25°C). ULTRA LOWELECTRICAL DATA 0 NOCT TSM-225 TSM-230 TSM-235 TSM-240 TSM-245 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 RESISTANCE _ Maximum Power Vol 26.916 168 172 175 178 rr:.ti?n� e ® Maximum Power Voltage(VJ 27.1 27.4 27.7 27.8 GROUND BOND CONNECTION coo Maximum Power Current(A) 6.12 6.20 6.27 6.32 6.41 10X BETTER THAN UL MINIMUM CRITERIA 0 "aF ( Open Circuit Voltage(V) 33.8 33.9 34.0 34.1 34.2 &0°, "a` _ Short Circuit Current(A) 6.62 6.M 6.70 6.75 6.83 s\ Back View NOCT:Irradiance at 800W/m',Ambient Temperature 20°C,Wind Speed 1M/s. i \ .. 's. C. MECHANICAL DATA •l Solar cells Multicrystalline 156 x 156mm(6 inches) t \3, yk r\ \'s\ s\ \\ ' \ ''. .� ..,, �` , -I� Cell orientation 60 cells(6 x 10) tit,-\ >t \ \ \ ',' i t I Module dimension 1650 x 992 x 40mm(64.95 x 39.05 x 1.57 inches) -ti �-L-, Weight 20.3kg(448 Ib) s41 \ \ l i L Glass High transparancy solar glass 3.2mm(0.13 inches) , 1 ...� Frame Anodized aluminium alloy i l Li. y,., . ' J-Box IP 65 rated '-' AA Cables/Connector Photovoltaic Technology cable 4.0mm'(0.006 inches'), 1100mm(43.3 inches),MC4/H4 I-V CURVES OF PV MODULE TSM-230PC05/PA05.18 9e I 1000W/m' 800) TEMPERATURE RATINGS 7e - /mY Nominal Operating Cell 46°C(±2°C) 60°' - _- Temperature(NOCT) 600W/m' 0 4°D goow/mT-�----------' -�-- ---- Temperature Coefficient of Po,a -0.43%/°C 50° c v 3e Temperature Coefficient of Voc -0.32%/°C 2000/m' --"'"'-'"--1-1 29' __ ____ Temperature Coefficient of Isc 0.047 [y . : 11 { f[D C I p L 1i'_ \ 5� 1 (.., NO SUITABLE FOR COMBINING PV MODULE EXPERTISE WITH A HIGHLY 09° - uiidir7g [�epa'tment I 000 10m 20)° 300° 400° MAXIMUM RATINGS - °":'+t �� INNOVATIVE MOUNTING SYSTEM SOLUTION. Voltage(V) j`' .'`.tw. ., Ems COMPOSITION SHINGLE Operational Temperature -40-085°C A�'rc 2013 �w Trina Solar is introducing Trinamount-the fastest,easiest and least Maximum System Voltage 1000V DC(1EC)/60DV m expensive way to mount PV modules onto residential and commercial DC(UL) � FOR ® rooftops.With a serves of drop-in and quarter-turn connections on a Max Series Fuse Rating ,sA CODE COIF PLl CE TRAPEZOIDAL METAL specialized module frame,this mounting solution installs up to 5 times CERTIFICATION faster than conventional mounting systems.Trinamount connects e 'acv�'��� �Y �=j7i i • directly to the module frame,eliminating the need for long rails. C E ISO PV CYCLE %I1 D 4L Us WARRANTY • 2n V n-; =ED 8 Bydrasticallyreducingthe number ofparts,cost of materials and / STANDING SEAM ROOF 10 year workmanship warranty installation time,Trinamount offers the optimal solution for residential :...r-i:":2A.solar 25 year linear performance warranty =r and commercial installations. 11 a (Please refer to product warranty for details) C �OMPgr� f Trinasolar W a CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. ` The power behind the panel 6.OHPPt' The power behind the panel •2011 Irina Solar Limited Al rights reserved.Specifications included is this dalasheet ore subject to change without notice. SolarCity SleekMountTM - Comp SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listedInstallation Instructions is optimized to achieve superior strength and Zep Compatible",modules aesthetics while minimizing roof disruption and }j, Drill Pilot Hole of Proper Diameter for labor.The elimination of visible rail ends and •Interlock and grounding devices in system UL Fastener Size Per NDS Section 1.1.3.2 listed to UL 2703 mounting clamps, combined with the addition Ory 4, 2 Seal pilot hole with roofing sealant of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 C p t as"Groundingand BondingSystem"Y 3 Insert CompMount flashingunder upper to a more visually appealing system.SleekMount pp utilizes Zep CompatibleTM modules with •Ground Zep UL and ETL listed to UL 467 as layer of shingle strengthened frames that attach directly to grounding device Zep Solar standoffs, effectively eliminating the 4 Place Comp Mount centered need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition 5 Install lag pursuant to NDS Section 11.1.3 •Anodized components for corrosion resistance shingles are not required to be cut for this with sealing washer. ir system, allowing for minimal roof disturbance. •Applicable for vent spanning functions isaiii,. 6 Secure Leveling Foot to the Comp Mount using machine Screw 7 Place module 4"1" li.t A Components . _ Bim_ 0 5/16"Machine Screw < 0 g Leveling Foot , CM C Lag Screw D Comp Mount E . C Comp Mount Flashing U�� :5S?? J 1 ,1_4111.0 ��� 4 ERTINO ® _i + _ , , �ilc� nq Department ` �' rti ' 1 2013 1 .`IE.JVEr EOR CODE COMPLIANCE cOMVA i Y e ii 6y _/ N /1-117-L1/ Na e�T tit. SolarCity© January 2013 /�`e LISTED SolarCity ® January 2013 Powe-ore= `Renewable Energy Solutions AURORA TECHNICAL DATA VALUES PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-4.2-OUTD-US i Nominal Output Power W 3000 3600 4200 Maximum Output Power W 3000 3300" 3300" 3600 4000" 4000" 4200 4600" 4600" o Rated Grid AC Voltage V 208 240 277 208 240 277 208 240 277 Z Input Side(DC) Number of Independent MPPT Channels 2 2 2 PVI-3.0-TL Q Maximum Usable Power for Each Channel W 2000 3000 3000 Absolute Maximum Voltage(Vmaz) V 600 600 600 C Start-Up Voltage(Vstart) V 200(adj.120-350) 200(adj.120-350) 200(adj.120-350) Full Power MPPT Voltage Range V 160-530 120 530 140 530 PVI-3.6-TL 9 9 Operating MPPT Voltage Range V 0.7xVstart-580 0.7xVstart-580 0.7xVstart-580 A/ Maximum Current(Idcmax)for both MPPT in Parallel A 20 32 32 PVI-4.2-TI Maximum Usable Current per Channel A 10 16 16 Maximum Short Circuit Current Limit per Channel A 12.5 20 20 Number of Wire Landing Terminals Per Channel 2Pairs(1on-S version) 2Pairs(1on-5 version) 2Pairs(1on-S version) GENERAL SPECIFICATIONS Array Wiring Termination Output Side(AC) Terminal block Pressure Clamp,AWG10-AWG4 C?llTf)(?r?R M(�f)F! `':.tiaa� i:..., Grid Connection Type 10/2W Spin 10/2W 10/2W Split- 10/2W 10/2W Split- 10/2W 0/3W 0/3W 0/3W Adjustable Voltage Range(Vmin-Vmax) V 183-228 211-264 244-304 183-228 211-264 244-304 183-228 211-264 244304 < Grid Frequency Hz 60 60 60 li Adjustable Grid Frequency Range Hz 57-60.5 57-60.5 57-60.5 0 Maximum Current(lacmax) ARN,, 14.5 14.5 12 17.2 16 16 20 20 20 CG Power Factor >0.995 >0.995 >0.995 The most common residential inverter is the ideal size for an average- --, Total Harmonic Distortion At Rated Power % <2 <2 <2 sized family home. This family of single-phase string inverter < Grid Wiring Termination Type Terminal block Pressure Clamp,AWG10-AWG4 complements the typical number of rooftop solar panels,allowing Protection Devices Input home-owners to get the most efficient energy harvesting for the ��� Reverse Polarity Protection Yes Yes Yes size of the property.This rugged outdoor inverter has been designed ../.✓����e 'W - Over-Voltage Protection Type Varistor,2 for each channel Varistor,2 for each channel Varistor,2 for each channel -- PV Array Ground Fault Detection Pre start-up Riso and dynamic GFDI(Requires Floating Arrays) as a completely sealed unit to withstand the harshest environmental Output conditions. Anti-Islanding Protection Meets UL1741/IEE1S47 Meets UL 1741/IEE1547 Meets UL 1741/IEE1547 requirements requirements requirements Over-Voltage Protection Type Varistor,2)L,-Lr/L,-G) Varistor,2(L,-L,/L,-G) Varistor,2(L,-L2/L,-G) One of the key benefits of the Uno family of single-phase inverters Maximum ACOCPDRating A 20 20 15 25 20 20 25 25 25 is the dual input section to process two strings with independent 111111111111111111=1 Efficiency MPPT especially useful for rooftop installations with two different ) Maximum Efficiency % 96.9 97 97 CEC Efficiency % 96 96 96 orientations(ie East and West).The high speed MPPT offers real-time - - Operating Performance Stand-by Consumption Wx,,,s <8 <8 <8 power tracking and improved energy harvesting. • • Night time consumption WPM <0.6 <0.6 <0.6 Communication The transformerless operation gives the highest efficiency of up to User-Interface 16 characters x2lines LCD display Remote Monitoring(1xRS485 incl.) AURORA-UNIVERSAL(opt.) 97.0%. The wide input voltage range makes the inverter suitable to Wired Local Monitoring(1xR5485incl.) PVI-USB-R5485_232(opt.),PVI-DESKTOP(opt) low power installations with reduced string size. Ili Wireless Local Monitoring PVI-DESKTOP(opt.)with PVI-RADIOMODULE(opt.) ) Environmental Ambient Air Operating Temperature Range °F(°C) -13 to+140(-25 to+60)with -13 to+140(-25 to+60)with -13 to+140(-25 to+60)with derating above 131(55) derating above 131(55) derating above 113(45) Ambient Air Storage Temperature Range °F(°C) -40 to 176(-40 to+80) -40 to 176(-40 to+80) -40 to 176(-40 to+80) Relative Humidity %RH 0-100 condensing 0-100 condensing 0-100 condensing Acoustic Noise Emission Level db(A)@1m <50 <50 <50 e . Maximum Operating Altitude without Derating ft(m) 6560(2000) 6560(2000) 6560(2000) Mechanical Specifications Enclosure rating NEMA 4X NEMA 4X NEMA 4X Cooling Natural Convection Natural Convection --:e'3 Natural Convecti ""�y i�' • Each inverter is set on specific grid codes which can be selected in the field Dimensions(H x W x D) in(mm) 33.8 x 12.8 x 8.7(859 x 325 z 222)-S VersiB! PE R TI I°�O • Single phase output Weight Ib/(kg) <47.3(21.3)-S version <47.3(213)-5yei;ion <47.3(21.3)-Svi slonji-iing Department • Dual input sections with independent MPPT,allows optimal energy harvesting from two sub-arrays oriented in Mounting System Wall bracket Wallbrackef Wall bracket Trade size KOs:(2ea x 1/21 and Trade size KOs:(tee i1/2")and Trade size KOs:(tea x 1/2")and different directions Conduit Connectionsoon (2ea x 1-1/4°3 places side,front, (2ea x 1-1/4,3 places side,front, (2ea x 1-1/4°3 places side,front,t • Wide input range mar) rear) : rear) _(��i DC Switch Rating-)Per Contact) AN 25/600 25/600 25/600 • High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting Safety • Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across Isolation Level Transformerless(Floating Array) Transformerless(Floating Array) Transformerless)FbKrig ay)L'0MFLIANCE Safety and EMC Standard UL 1741,CSA-C22.2 N.107.1-01 UL 1741,CSA-C22.2 N.107.1-01 UL 1741,CSA-C22.2N.107.1"31 the entire input voltage and output power range Safety Approval ,CSA", ,CSA„ ,CSA,. • Outdoor enclosure for unrestricted use under any environmental conditions Warranty ri:d v:e'riC:;;1 <i /fi;N /ATS • Integrated DC disconnect switch in compliance with international Standards(-S Version) Standard Warranty years 10 10 10 Extended Warranty years 15&20 15&20 15&20 • RS-485 communication interface(for connection to laptop or datalogger) Available Models • Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP Standard-Without DC Switch and Wiring Box PVI-3.0-OUTD-US PVI.3.6-OUTD-US PVI-4.2-OUTD-U5 With DC Switch and Wiring Box PVI-3.0-OUTD-S-US PVI-3.6-OUTD-S-US PVI-4.2-OUTD-S-US 'All data is subject to change without notice "Capability enabled at nominal AC voltage and with sufficient DC power available ••.When equipped with optional DC Switch and Wiring Boa CSA INTERNATIONAL Certificate of Compliance Certificate: 2096477 Master Contract: 173688 Project: 2439385 Date Issued: July 19,2011 Issued to: Power-One,Inc 740 Calle Plano Camarillo,CA 93012 USA Attention:Robert White The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C'and 'US'for Canada and US or with adjacent indicator 'US'for = US only or without either indicator for Canada only. Ro1irftempstoc1c Issued by: Rob Hempstock,AScT. C US PRODUCTS CLASS 531109 -POWER SUPPLIES-Distributed Generation Power Systems Equipment CLASS 531189 -POWER SUPPLIES-Distributed Generation-Power Systems Equipment -Certified to U.S.Standards Utility Interactive Inverter,Models PVI-4.2-OUTD-US,PVI-3.6-OUTD-US,PVI-3.0-OUTD-US,PVI-4.2- OUTD-S-US,PVI-3.6-OUTD-S-US,PVI-3.0-OUTD-S-US,PVI-4.2-OUTD-US-W,PVI-3.6-OUTD-US-W and PVI-3.0-OUTD-US-W;provided with two DC input channels,permanently connected. For details related to ratings,reference should be made to the CSA Certification Record,Appendix 1 or the Descriptive Report. CUPERTINO APPLICABLE REQUIREMENTS � !iding Department CSA-C22.2 No.107.1-01 - General Use Power Supplies 2013 3 UL Std No. 1741-Second Edition - Inverters,Converters,Controllers and Interconnection System Equipment for Use With Distributed Energy Resources(January 28,2010) c L l r_ ; Nv D FO CODE COMPLIANCE By _ 47e9.201 DQD 507 Rev.2009-09-01 Page:1 r