10110157 CITY OF CUPERTINO BUILDING PERMIT
BUILDING ADDRESS: 21740 GRANADA AVE CONTRACTOR:DRI COMMERCIAL PERMIT NO: 10110157
CORP
NER'S NAME: BELL PROPERTIES 17182 ARMSTRONG AVE DATE ISSUED: 11/23/2010
OWNER'S PHONE: 4083704800 IRVINE,CA 92614 PHONE NO:(949)266-1990
LICENSED CONTRACTOR'S DECLARATION
// BUILDING PERMIT INFO: BLDG r ELECT r PLUMB r
License Class Lic.# � � � L, �-
MECH r RESIDENTIAL r— COMMERCIAL
Contractor Date 1(/z3//b
I hereby affir���,2eovisions of Chapter 9 JOB DESCRIPTION: RE-ROOF 35 SQ TEAR OFF EXISTING BUR NO RESHEET
INSTALL 60 M.I TPO SYSTEM CLASS A
(commencing with Section 7000)of Division 3 of the Business&Professions
Code and that my license is in full force and effect.
I hereby affirm under penalty of perjury one of the following two declarations:
I have and will maintain a certificate of consent to self-insure for Worker's
Compensation,as provided for by Section 3700 of the Labor Code,for the
performance of the work for which this permit is issued, Sq.Ft Floor Area: Valuation:$13441
I have and will maintain Worker's Compensation Insurance,as provided for by
Section 3700 of the Labor Code,for the performance of the work for which this APN Number:35717054.00 Occupancy Type:
permit is issued.
APPLICANT CERTIFICATION
I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED
correct.I agree to comply with all city and county ordinances and state laws relating WITHIN DF PERMIT ISSUANCE OR
to building construction,and hereby authorize representatives of this city to enter
upon the above mentioned property for inspection purposes. (We)agree to save 18 YS F T CALLED INSPECTION.
indemnify and keep harmless the City of Cupertino against liabilities,judgments,
costs,and expenses which may accrue against said City in consequence of the
granting of this permit. Additionally,the applicant understands and will comply Issued by: Date: ff
with all non-point source regulations per the Cupertino Municipal Code,Section
9.18.
/I -Z RE-ROOFS:
D
ature All roofs shall be inspected prior to any roofing material being installed.If a roof is
installed without first obtaining an inspection,I agree to remove all new materials for
inspection.
❑ OWNER-BUILDER DECLARATION
Signature of Applicant: �CLASS'-'A"
( � /
I hereby affirm that I am exempt from the Contractor's License Law for one of
the following two reasons: ALL ROOF COVE TOOR BETTER
I,as owner of the property,or my employees with wages as their sole compensation,
will do the work,and the structure is not intended or offered for sale(Sec.7044,
Business&Professions Code)
I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE
construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the
California Health&Safety Code,Sections 25505,25533,and 25534. I will
I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the
declarations: Health&Safety Code,Section 25532(x)should I store or handle hazardous
I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous
Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I
performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and
I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505,2553 and 25534.
Section 3700 of the Labor Code,for the performance of the work for which this
permit is issued. Owner or authorized agent: Date:
I certify that in the performance of the work for which this permit is issued,I shall
not employ any person in any manner so as to become subject to the Worker's
Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY
become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of
forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.)
Lender's Name
APPLICANT CERTIFICATION Lender's Address
I certify that I have read this application and state that the above information is
rrect.I agree to comply with all city and county ordinances and state laws relating
iilding construction,and hereby authorize representatives of this city to enter
,.,n the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION
indemnify and keep harmless the City of Cupertino against liabilities,judgments,
costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records.
granting of this permit.Additionally,the applicant understands and will comply
with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional
9.18.
Signature Date
CITY OF CUPERTINO
4 ITEMS OF 4 PERMIT RECEIPT OPERATOR: SylviaM
COPY # 1
Sec: Twp: Rng: Sub: Blk: Lot:
APN . . . . . . . . : 35717054 . 00
DATE ISSUED. . . . . . . : 11/23/2010
RECEIPT #. . . . . . . . . : BS000012079
REFERENCE ID # . . . : 10110157
SITE ADDRESS . . . . . : 21740 GRANADA AVE
SUBDIVISION . . . . . .
CITY . . . . . . . . . . . . . . CUPERTINO
IMPACT AREA . . . . . . .
OWNER . . . . . . . . . . . . : BELL PROPERTIES
ADDRESS . . . . . . . . . . : 21740 GRANADA AVE
CITY/STATE/ZIP . . . : CUPERTINO, CA 95014
RECEIVED FROM . . . . : JEFF RAINEY
CONTRACTOR . . . . . . . : BRIAN FLAHERTY LIC # 27660
COMPANY . . . . . . . . . . : DRI COMMERCIAL CORP
ADDRESS . . . . . . . . . . : 17182 ARMSTRONG AVE
CITY/STATE/ZIP . . . : IRVINE, CA 92614
TELEPHONE . . . . . . . . : (949) 266-1990
FEE ID UNIT QUANTITY AMOUNT PD-TO-DT THIS REC NEW BAL
---------- ------------- ---------- ---------- ---------- ---------- ----------
1BCBSC VALUATION 13,441.00 1. 00 0 .00 1. 00 0 .00
1BSEISMICO VALUATION 13,441 .00 2 . 82 0 .00 2 .82 0 . 00
1BUSLIC FLAT RATE 1.00 114 . 00 0 .00 114 .00 0 . 00
1REROOFCOM SQUARES 35 .00 348 . 00 0 .00 348 .00 0 . 00
---------- ---------- ---------- ----------
TOTAL PERMIT 465 .82 0 .00 465 .82 0 .00
METHOD OF PAYMENT AMOUNT REFERENCE NUMBER
----------------- --------------- --------------------
CREDIT CARD 465 . 82 visa
---------------
TOTAL RECEIPT 465 . 82
VOICE ID DESCRIPTION VOICE ID DESCRIPTION
-------- ---------------------------- -------- ----------------------------
309 EXTERIOR LATH 311 SCRATCH COAT
601 ROOF TEAR OFF 602 ROOF PLYWOOD NAIL
604 ROOF IN-PROGRESS 605 FINAL REROOF
REROOF TEAR-OFF POLICY
COMMUNITY DEVELOPMENT DEPARTMENT-BUILDING DIVISION
ALBERT SALVADOR,P.E.,C.B.O.,BUILDING OFFICIAL
CUPERTINO 10300 TORRE AVENUE-CUPERTINO,CA 95014-3255
(408)777-3228•FAX(408)777-3333-buildingecugertino.ora
PROJECT ADDRESS I / L40 ' P-A AV A 11h,1C APN#
OWNER NAME 5C ` f F� ,>JLZ7 I -, PH TGC7' go, E-MAIL
STREET ADDRESS ( 12 '-�-"f I CITY, STATE,`J7IP JC)7 C.I'r FAX
CONTRACTOR NAME J I KJ ^� �1 LICENSE NUMBER LICENSE TYPE BUS.LIC.#
OT-I Cf7V►�)Nq l-iZ-Gi��{'L GC.1,21 1 6 z-3 3
COMPANY NAME E-MAIL FAX 4 1 Z
STREET ADDRESS CITY,STATE,ZIP PHONE
't r LKS B�-+-` n: c h.�:�,7 c cit .���1 S 7 7 �v 54 y y ►c��-�;
I UNDERSTAND AND AGREE TO THE FOLLOWING:
1. The re-roof project shall comply with all applicable provisions of the 2007 California Building Code.
2. You must schedule all needed inspections a minimum of one day before the requested inspection date.
Please schedule inspections online or call (408)777-3228 between 7:30-3:30 (Mon-Fri).
3. Tear-off roof inspection is required. Please call for tear-off inspection after the roof is torn off and all
the nails/fasteners have been removed. Any and all dry-rotted wood shall be replaced prior to this
inspection. A building inspector will be available within one hour.
There are special hours for this service: 7:30 — 10:30am and 1:00—3:30pm(Mon—Thurs);
7:30 — 10:30am and 1:00—2:30pm(Friday).
4. If plywood is installed, a plywood nailing inspection is required.
5. In-Progress roof inspection is required. Call for an in-progress roof inspection to verify building is
weather tight after installation of approximately 25% of the roofing material.
6. New roof coverings shall not be applied without first obtaining all inspections and written approvals
from the building inspector. Any roofing which is applied without first obtaining an approved inspection
will require the removal of all new material down to the sheathing so a proper inspection can be
performed.
7. A final inspection and approval shall be obtained from the building inspector when the re-roofing is
complete. To receive a final sign-off, the following items will be verified:
a. Flat roofs shall have a minimum of I/4"per foot of slope and must demonstrate there is no ponding.
b. Listings from approved testing agencies for all pre-manufactured products used shall be available
on-site to review at the time of the inspection.
c. Proper spark arrestor installation.
8. NOTE: If you call for a tear-off or plywood nailing inspection and the work is not complete, you will
be charged a re-inspection fee of$126.00. The re-inspection fee shall be paid before another
inspection can be scheduled.
By my signing below, I certify each of the following is true: I am the property owner or authorized agent to act
on the property owner's behalf. I u d and agree to comply with the re-roof policy stated above.
Signature of Applicant/Agent: Date: 11
RerooJPolicy_2010.doc revised 05/17/10
CITY OF CUPERTINO
FEE ESTIMATOR-BUILDING DIVISION
ADDRESS: 21740 granada ave. TD-ATE- 11/23/2010 REVIEWED BY: bobs.
APN: BP#: *VALUATION: 1$13,441
xPERMIT TYPE: Minor Building Permit PLAN CHECK TYPE: Re-roof
PRIMARY Commercial BuildingPENTAMATIOt �ji 11='f :l. PERMITTYPEN 1COMMLROOF
USE:
WORK tear off existing BUR. no resheet. Install 60 mill TPO system. Class A. 35 sq.
SCOPE
FEE ID ROOF AREA
s.f.
1REROOFCOM 3,500
1 1ctrrC'yrc>ch
1 T
14"crt 1-1 (
1J7.`i�. E.� i`lair! )r,�Ir`i'. .1/f�j'�.(C i CPI.�f.1,
Li
1k,h, h V). kcc: i,iO hnp, fie
NOTE. Thesefees are based on the preliminary in ormation available and are only an estimate. Contact the De t or addh7 info,
FEE ITEMS (Fee Resohltiorr 09-051 Fjf ;%'1,"10) FEE QTY/FEE MISC ITEMS
P/an Check Fee:
S11ppl. I'("'F(V
P1111171)./:tf 1 i1./Z1�c P1011
Permit Fee: $348.00
S11ppl. Insp Fee
1'1111rzf1.'�tc^c/t.il;lcc: C'i�it f�'e{:
f'lurrth.;';�1cc•11.�151�'c� T'crrlltrf T-c:c::
E�.`c�lzstrrlt bort 7'ax
,'1<:r�ttstic'ttl Ii'eriErt1'I=r'�':
Work Without Permit? 0 Yes E) No $0.00
I'lannilt", t 4,cs:
Ti uti e1 I)ocl nctitalion
Strong Motion Fee: 1BSEISMICo $2.82 Select an Administrative Item
Bldy,Stds Commission Fee: IBCBSC $1.00
SUBTOTALS: $351.82 $0.00 TOTAL FEE: $351.82
Revised: 11/08/2010
Nov 23 10 08:46a Suzy Rainey (510) 783-1041 p.1
EVALUATIONICC
ISS SERVICE
ESR-'i 46
ICC-ES Evaluation spa Reissued October 1, 201
Underwriters ICC-EL 7-hisWolf.is subject to re—examinattori in two year.
U , LaborawieS Dual R port
Ctick on the logo to ectesS UL Card etron
rnWw.icc-es.or�c j (800)4 3-6587 ( 62)699-0543 A ubsi racy of the international Code Courrci�'
DIVISION: 07 IDD 00—THERMWA AND mosi URE 20 USES
PROTECTION 1 Car ale thylene propylene diene monomer (EPDM),
Section:07 53 23-.--Ethytene- ropytene D e Wnomer po vinyl chloride (PVC) and thermoplastic polyolefin
Roofing (TP ) sir gle-ply roofing membranes are used as i roof
Section:07 54 19--Polyvinyl' hloyicie Roo ng cov rings in adhered and mechanically fast ned
Section:07 54 23 Thermopt stic-poly3lpfin Roofing me,nbrane roofing systems,
REPORT HOLDER: 3.0 ESC 1PT10N
3.1 General:
CARLISLE SYNTEC INCORPORATED i
PO BOX 7000 Th EPDLn, PVC and TPO Membrane Roofing Systems
CARLISLE,PENNSYLVANIA 7013 cle.cribad in this report consist of single-ply r ofing
(717)245-7000 me bran s, insulation where used, barrier board o slip
wvtw cartisle-syntec.com sh at w ere used, flashing, mechanical fasteners and
adliesive that are installed on a combustibl or
no corn stible dock. See Table 1 for Carlisle pr duct
EVALUATION SUBJECT:
I�I tra e names and corresponding product name for
CARLISLE EPDM,PVC AND PO SINGL LY P.00FING M le-Hid iii Products Company, Inc., WeatherBond,Versico
MEMBRANES Incarpor d and Kelly Company/2001 Inc., the additional
lisi Des.
ADDITIONAL LISTEES: i 3, EPE iMR*Mbranes:
VERSICO INCORPORATED � 3. .1 Sire-Seal: SurwSeal is a black, nonreinforced
POST OFFICE BOX 1289 EF DTVI nembrane available in 45-, 60- and 90-mil
CARLISLE,PA 17013 (1 14, 1. 2,and 2.29 mm)thicknesses.
MULE-HIDE PRODUCTS CO PANY,I�I 3. 2 re Seat FR: Sure-Seal FR is a black,
n rein ced EPDM membrane with fire retardants,
1195 PRINCE HALL DRIVE
av 'abl in 45-, 6& and 90-mi (1,14, 1.52, and 2.29 mm)
BELOIT,WISCONSIN 53511 th
fknes es_
I
WEATIiERBOND , i 3. .3 re White: Sure-White is a white, nonreinfiorced
P.O.BOX 251 E DM r lembrane available in a 60- and 90-mil (1.52 and
PLAINFIELD,PENNSYLVAN A 17081 2. 9 m thickness,
KELLY COMPANY/2001 INC 3. 4Ire-Tough
re-Tough: Sure-Tough is a black, reinforced
m mbrconsisting of a polyester reinforcement
325 THQMASTON AVENUE a capsted between two EPDM membrane plies. It is
1NATERBURY,CONNECTIC T 06702 a ailabn 45-to 75•mil(1.14 to 1.90 mm)thicknesses.
1.0 EVALUATION SCOPE 3. 5 FR: Sure-Tough FR is a black,
Compliance with the folloi Ang codt S inforci d membrane consisting of a pdyester
rc inforci ment encapsulated between two EPDM
:2006 International B uildif 9 Codec embre ne plies with fire retardants. it is available in 45 to
■2006 International Resid nfial Code"(I C) 6 -mil( .14 to 1.52 mm)thickness.
■Other Codes(see Sectio 8.0) 32.6 ure-Seal FleeceBACK: Sure-Seal FleeceBACK is
a 45-,6 or 90-mil(1.14, 1.52 or 2.29 mm)non-reinforced
Properties evaluated: EPOM bonded to a 5.6-ounce-per-square-yard (0.18
■Weather resistance k !m2) olyester fleece.
■Roof covering fire Bassi cation 3 2.7 re-White FleeceBACK:Sure-White FleeceBACK
i a 60 or 90-mil (1.52 or 2.29 mm) nonreinforced white
■Wind uplift resistance EPDM 'bonded to a 5.--ounce-per- square-yard (0.18
■Impact resistance Ic lm)polyester fleece.
ec fical
!CC-.W El�atuavor,f'poris are nor to be eonstn¢d as ep¢ a¢sth¢itcs w press w implied as as ar}y other ams les not ty address¢d,nor oraey fob¢eonuru
as an endorsement of the subjecr cf the r ort or a rec ¢ n 6r its use.21wre is no wary rrjy by J C Elri>rahox Service,LLC,tx ��
to any f nding or other m 7ior jr,this rzp rt or as ro an p o ct!coti¢red by rhe report.
Pagel ofio
Copyright®2010
i
i
Nov 23 10 08:46a Suzy Rainey (510) 783-1041 p.2
I i t t-dyC t ul I u
ESR-1463 4 Il4ost idefyAcce ed orad T
3.2.8 Sure-Seal 'AFX: Sure- eal AFX i 5- �- or 3. 1 Sp it o-Weld FleeceBACK: Spectro-Weld
with a
90-mil (1.14, i., or 2.29 m} non-e n e EPDM FI a eBA is the ppectrgo-Weld membrane kg/m
}
bonded to a 7 -ounce per square-y 4 villi kglm') la i ated j 5,5-ounce- er-s uare-yawl (0.18
polyester fleece.
polyester fl ece backing.
32.9 Sure-Seal AFX PLUS Sure se 1 X P US is a
3 5 nsul on:
60-mil (1.52 m non-rein ed EP M or d to a able 2 through 4 for insulations for use with specific
7.5-ounce-per-sq are-yard(0. 5 kg/m') !y stir eece. r of, g ms. Foam plastic insulation, where used must
h ivE a flme-spread index of not more than 75 when
3.3 PVC Memb es: I t st d at he maximum thickness intended for use in
3.3.1 Sureflex and sure-Flex Elval y ufe-rlex and c rdanc with ASTM E94.
Sure-Flex Elvaloo are 50-, 6 , or 80- i+ (1.27,' 1.52, or 3.6 Barri r 8oard-
2.03 mm) me branes c sisting of a polyester
oration
reinforcement a psulated etween to li s 1 of PVC. arr�er bard, where used, must Gypsum either minimum
The membrane i available in bite, gra ar ustotn colors. „4e sflec minimum m1)f4-inGch-thy k (6.4 mm) Owens
3.3.2 Sure-Fle FRS and Sire-Flex Ir! ;FF S:cure or ing ataguard", minimum fa-mch-thick (6,4 mm)
Flex FRS and ure-Flex aloy FR ar 01, 6 , g "Se urock," or minimum 1h-inch-thick (12.7 rnm)
80-mil (1.27, 1.5 , or 2.03 m ) rnemb nes consisting of a m b" rd. Barrier board must be UL-listed for roofing
fiberglass reinfocement enc sulated et een!two plies F icatio s or UL-classified gypsum board.
of PVC. The mbrane is available in 1hiite� gray or 7 tulip heet:
custom colors.
i h slip Iheet, where used, must include Carlisle "FR
3.3.3 Sure-Fie FRS FI eceBAC lure-Flex a Sh et 1 S or 2S," Elk 'VersaShield Underlayment,"
Elvaloy FRS FI eceBACK: Sure-Flex F 5 HeleceBACK k `1/er aShield FB-1S. or FB-2S, or Atlas FR 10 or
and Sure-Flex E aloy FRS F eeceBAC(er the Sure-Flex „
FRS membran and th Sure-Fex Elvaloy FRS R'0'
membrane, des ribed in Se ion 3.3. iw th.a Jarrinated 8 Flas ling:
o e r fleece 5.6-ounce-per- ware-yard ( .18 kg/ )i hl' site la ing �� st be provided in accordance with IBC Section
backing. I 1503.2 r1 IRC Section R903.2, as applicable. Where
3.4 TPO Mem ranes: flashing i i of metal, the metal must be corrosion-resistant,
I i imum No.26 gage 10.019 inch (0.483 mm)] galvanized
3.4.1 Sure-W d: Sure-Weld is a 4 or 60-rr}il (1.114 or steel.
1.52 mm) embrane donsisting o 6 polyester
I 3.9 Fasteners:
reinforcement ncapsulated between tOc phre of TPO.
The membrane is available in white, ra tan�or custom Fa ener used to mechanically attach insulation and
colors. m mbra es to the roof deck, must be corrosion-resistant,
an mu be Carlisle fasteners, plates or fastening bars,
3.4,2 Sure-111 Id HS: Sure-Weld H 3, lis the Sure Weld un ess o herwise noted in this report. Refer to Table 4 for
membrane for ulated with an additional Bam, retardant sp acingo.fasteners.
for fire resistan a at higher slopes. l is nuffactured in 3. ,1 reSea! HP Fastener: This is an epoxy-coated
45- and 60-mi (1.14 cr 1 52 mm) biic ness0s, and is st sc Iw used in combination with Carlisle's fastening
available in whii e, gray, tan custom olo s., plates ot bars to mechanically attach roofing insulation and
3.4.3 SAT-TP:): SAT-TPC is a sell-ii'd sell-ii' ered version ofrmbra es to steel or wood substrate. Fastener length
Sure-Weld HS embrane w h adhesi e; must b selected to penetrate through the steel deck a
m ni.MU I of 14 inch (19.1 mm), and into the wood deck a
3.4.4 Sure-W d EXTRA: ure Wel E RA;s the same m nimu iof 1 inch(255.4•mm).
formulation as the Sure- Id mem ran 6 comes in
72-and 80-mi 1.83 and 2. 3 mm)thick i se:. 3. .2 re-Seal HP Purlin Fastener: This is an epoxy-
72- ated el screw used in combination with Carlisle's
3.4.5 Sure-W ld HS EX : Sur e d EXTRA is nin plates or bars to mechanically attach roofing
the same for lation as th Sure-We d a rane but in ulati and membranes to structural steel members.
comes in 72 d 80-mil (1. and 2. In ) hi knesses. F sten length must be selected to penetrate through the
3.4.6 Sure- d Fleet CK: Su I I eeceBACK 1 ber a minimum of314 inch (19.1 mm.)
is the Sure W d HS me rare, or 0� Is (1.14 or 9.3 re-Seal KD 14-1D Fastener: This is a heavy-
1,52 mm) the with a la inated 5!o nCe er-square- d ty, a oxy-coated steel suev�� used in combination with
yard (0.18 kg! �) polyester eece ba ih rlisle fastening plates or bars to mechanically attach
I roofing sulation and membranes to concrete roof deck.
3.4.7 Sure- eld AFX: ure-Weld is',the 45-mil F:iLsten S length must be selected to penetrate into the
(1.14 mm) re-Weld H membra a ith d laminated c ncret deck a minimum of 1 inch (25.4 mm).
10-ounce-ped quare yard (0.34 k !) polyester fleece
backing. i 3 9A re-Seal HP Polymer Seam Platte: This is a
inch- iometer (50 mm) polymer plate designed to be
3.4.8 Sure- eld AFX PLUS: Su -W. d A % PLUS is used th sure-Seal HP and Sure-Seal HQ 14-10
the 60-mil (1. mm) Su a-Weld Se�nb ane with a sten s to mechanically attach roofing membranes to the
laminated 0-ounce-pe square-y rd (0. kglm) r of de �C.
potyester fle�C backing. 9.5 re-Tite Fastener and ST Fastening Bar: This is
3.4.9 Sped -Weld: Sp actro-Wel J 1 i the Sure-Weld he duty, epoxy-coated steel screw and bar used to
membrane, tl scribed in Section A�.1 an Sure-Weld ecure reinforced EPDM membranes to steel or wood
EXTRA mem rare, des d in Section 3.4.4, formulated eck. he bar is 1-inch-wide-by-0.040-inch-thick-by-10-
with a brightI white color. It is mar ufacturecl in 45-, 60-, ot-lor g(25A mm by 1.f mm by 3.1 m)galvalu me-coated
72- or 80-mil .14•, 1.52-, .83-or 2 3- m)thicknesses. eel w t prepunched holes 6 inches(150 mm)on center.
Nov 23 10 08:47a Suzy Rainey (510) 783-1041 p.3
Page 3 of 10
ESR-1463 l Mose idelyAcce ed and T st
us
3.9.6 HP-X Fas ner: This an n poithc the Piranha substrates-ates_ TheeedeSACK eadhesvesmbranes ahaven alacoverage atetions to of
steel screw us in co atio t roma ly 100 square feet per gallon (2.5 rr 1&)- The
Fastening Plate mechanical) attach T O e ran es to approxi
steel or wood su rate. Fast er length mu a selected a 89 ffiesL dr msare s cartridge tubes lloR cyn ders and have a
to penetrate thr h the steel eck a m ni nl o>f /4 inch ( )
{19.1 mm), and to the woo Ideck a ' i um Qf 1 inch el life o one year.
(25.4 mm). i 1 311 Imp Resistance:
3.9.7 Piranha Fastening ate: This i a 23/Tch- a'EPD , PVC, and TPC roofing membranes described
diameter galvalie-coated st �ji
I plated sig ed to be used i this re rt meet requirements for impact resistance in
with HP-X faste�i rs to rnech cally attach. Ond TPO l C Secti 1504.7, based on testing in accordance with
membranes tothe roof deck. I M4470.
3.9.8 HP-X-RA Fastener: This is -coated 4. I STA LAl10H
carbon steel sc w used in mbinatio w the Piranha
XTRA Fastenin Plate to m chanicall eit cit �Vc and 1 General:
TPO membran to steel wood s atJe. 'Fastener i s Ilati of the EPDM, PVC, and TPO roofing
length must be selected to 0enetrate th ujh the steel rnernbranom described in this report must comply with the
deck a minimur�ri of inch 19.1 mm) an in�o he wood applicable code, the manufacturer's published installation
deck a minimu f 1 inch(25 mm). I i st udio s and this report. The manufacturer's published
339,9 PiranhaXTRA Fa ening 13t This is a st llatio instructions must be available at all times on
2 Is-inch-diame r galvalume oated s ;I ite designed a'obsi during installation,
to be used with MP-XTRA fa Hers to ec anic lly attach TI ie suk strata to which the membrane is to be applied
PVC and TPO I bran es to the roof d ck. inust be clean, dry, and free of frost, loose fasteners, and
3.9.10 OMG Inc, RhinaBon I Plate:T e mol and Plate h r pr usions or contaminates that will interfere with the
is a 3-inch-dia ter (76.2 m ), 0.02&nch thick (0.7 mm) d esion or attachment of the membrane or that will
galvalume-coo steel pla coated wit a Iroprietary u cture a membrane. All materials must be protected
adhesive and u ed with the P-X fas er o mechanically g Inst ontact with incompatible materials. Where
attach PVC arj TPO mem vanes to a roof deck. The 1�sum and is used as barrier board in the roofing
adhesive bonds the plate ; to the Utntler,side of the as$embl ,;weather protection must be provided to prevent
membrane. da age o the gypsum board prior to application of the
3.10 Adheslv ra fing embrane.
3.10.1 Sure-S 1 90.8.30A: ure-Sea 9;0- 30A is a high- he sl pe of the roof on which the single-ply membranes
strength, solve -based con Oct adhe ive usedlto adhere ar inst led must not be more than the maximum slope
es to the i ulation a su tratie. K has a inicate for the particular assembly as listed in Tables
EPDM membra
coverage rate f approxima Oly 60 sq arefeetiper gallon 2 end 3.
(1.5 m'/L). The adhesive is isupplied in; gallgn (18.9 L) l enetir tions and terminations of the roof covering must
containers and ias a shelf li of one ar. be flash and made weather tight in accordance with the
3.10.2 sure-S 1 Aqua Ba 120: S re- ear Aqua Base requi ants of the membrane manufacturer and the
120 is a high-st ength,wake abased c nta t adhesive used aplplicab a code.
to adhere EPEDPA and TPO embrane fa thi6 insulation or 4.2 Fir Classification:
substrate. It h s a coves a rate o ap roxit�ratety 120 4,x.1 evy Con St
The adhered and mechanically
square feet per gallon (3 m l�).The a hes ve is supplied in fastene EPDM, PVC, and TPO single-ply membrane
5-gallon (18.9 L) contain ys and as a shelf life of roofing pystems, when installed in accordance with this
one year. I report, re Class A, B or C roof covering systems in
3.10.3 Sure-Flex PVC B ,ding A he ives:, Sure-Flex accorda ce witli ASTM E 108 and UL 790, as noted in
PVC and Sure- lex Low V PVC B ndi g Adhesives are Tables and 3.
high-strength,' olvent-bas contact a esives used to
adhere PVC embranes 0 an ins lati n ar substrate. 4.2.2 Reroofing: The existing deck must be inspected to
vori th t the structure to be reroofed is structurally sound
They have a c era9a rate approxi y 60isguare feet fi!
per gallon {i. m/L}. T adhesi es ars3 supplied in avid a equate to support and secure the roofing
5 ballon (18.9 )containers hash If li o one year, mbr ne. Prior to installation of new roof coverings,
I I in pectin by and written approval from the code official
3.10x4 Sure- d Ban 6g Ad esiISure-Weld h ving j risdicdon must be required.
Bonding Adfi gt sive is a high-sire solvent-based
contact adhesi a used to jdhere T j embranes to an Class A, B or C roof covering systems may be installed
insulation a substrate. � has :c era a rate of older sting classified roof covering systems under the
approximately 60 square et per g11,vel
II` (1.5 m21L). The Ilowin ; conditions with
additional roof Classification
adhesive is su plied in 5 11on (19. L) on iners with a tests, provided the resulting classification is the lower of
shelf life of o I year. j t e n or existing roofing classification:
3.10.5 Low C Bondin 'Adhesiv : Low V C Bonding New uninsuiated systems installed only over existing
Adhesive i� a high-str gth, s alas d contact unin i+lated assemblies.
adhesive use to adhere embranlt a,n i sulation or New insulated systems installed over existing
substrate. ltI as a covetrswith
�e rate of ppro�Cimately 60 unin rated systems only.
square feet pe gallon(1.51 L).Th ad esiv is supplied Resistance:
in 5-gallori(1�9 L) contain a �el life c Fane year. 3 W nd Res
3.10.6 FAST dhesives: AST 10 F ST 10OLV, FAST 4..3.1 New Construction: The allowable wind uplift
Adhesive Dual CartridgeFAST h sive' Box Sets, pressu s for the EPDM, PVC, and TPO roofing
Flexible FAS and FAS Bag-in-l-SoK Adhesives are membranes as parts of roof assemblies are noted in
two-component polyureth rr a adhe es used to adhere Tables 4 and 5.
I
Nov 23 10 08:48a Suzy Rainey (510) 783-1041 p.4
Page 4 Or 11J
ESR-1463 I Mose idely Acce and Tr sf
l
Metal edge cement for rooting �t ust be 5. buildings under the IBC, above-deck thermal
For
nsu[a on board must comply with the applicable
designed in acc r ante with SIlSPRI S 1, complying and ds listed in Table 1508.2 of the IBC.
with IBC Sectio 1504.5, a edge st u e vent for
mechanically att ched me vanes wa to ed in 6.D DEN E SUBNRTTED
accordance with ANSI/SARI ES-1 T s!t 12 , using
ed a 304 [0. 0-inch 112 rn ) 3003 to in a rdance with ICC-ES Acceptance Criteria
April
Carlisle Secur
aluminum] and ariisle Se rEdge 0 I[0. 0-inch a rave Roof Covering Systems (AC75), d
(1.02 mm)3003 aluminum) fa is syste
sl, he aximum 2)07, (carr cted December 2008).
allowable load r Carlisle ecurEdg 3 0 is 234 Of 7. E ENTI KATION
(348 kglm). Th maximum illowable loo j dor, Carlisle
SecurEdge 300p 200 plf(29 kgfm). I ac roll o the roofing membrane must bear a label noting
1 e produ name, the manufacturer's name (Carlisle
4.3.2 Re ro i : Mechanic I ouch ed ms may n ec to orporated) or the name of the additional listee,
be accepted sed on a adeq a� 7 anchors t,'e manu cturees address or plant code, the ICC-ES
penetrating thro� h existing of cover g$
into structural al ation report number (ESR-1463), and the name or
substrates. Sint the compo ion antU rl dttiori of any 1abeAoft inspection agency (Underwriters Laboratories
particular existiunderlying material mer f Vary widely, l� c
reroofing with a eyed syste is outs' e t scgpe of this r
report. 8. OTHE CODES
5.0 CONDITIONS OF USE additia to the codes referenced in Section 1.0, the
The single-ply E DAA, PVC, nd TPO oofi g membranes products i this report were evaluated for compliance with
described in th s report ply Willi, I aro. suitable the requir ments of the following codes;
alternatives to hat is speci d in, these de' listed in OCA National Building Code11999(BNBC)
Section 1.0 f this repor, subject J0 the following 1999 Standard Buifding Corley(SBC)
con dliitions:
5.1 Installation ust compl th the p li able code, the ■ 1997 niform Buildin Code-m (UBC)
man ufact is publish instailat n i 0ru 'ons and For c pliance under the above codes, see Sections 2
this repor. The instru ons with nl t isi r ort must rough of this report, except revise the following
govern i there are ny con icts lie een the coons read as follows:
manufact r is installati n instruc ons grid is report.
FI n
g:
5.2 The adhered and me apically fast nod single-ply Fleshing must be provided in accordance with SBC
membraneroofing sy ems mu I e I In stalled by
professional roofing co tractors ha a ained and Se on 503.2, BNBC Section 1508.1 and UBC Section
approved the manu urer. I 15 , as applicable.Where flashing is or metal; the metal
rM st be rrosion-resistant, minimum No. 26 gage [0.019
5.3 Foam pl is insulation must be s rate from the inch 0.4 rnm galvanized steel.
interior o e building an appy a ther al barrier ( )]
in actor ce with IB Section 26 314.5 or IRC 3.11 impResistance:
Section F 1 14.4, as ap ilcable.
I Thie EP Alt, PVC, and TPS roofing membranes described
5.4 Foam pia is insulatio ,! where sed mutt bear the in !this r ort meet requirements for impact resistance in
label of approved ency ind! ti g that the foam BNBC S tion 1505.4.2, and SBC Section 1504.6, based
plastic h� a flame-spr 'ad index of m re,than 75 onitestin in accordance with FINI 4470.
when to d at them imum th ckn ss intended for
use in a ordance wit ASTM 8 , su jest to the 4. .1 ew Construction: The allowable wind uplift
approval the code o ial. pr slur s for the EPDM, PVC, and TPO roofing
5.5 Design nd uplift es"sure n nr roof area, m rubra es as parts of roof assemblies are noted in
including ge and ner zones, ust of exceed
T tiles and 5.
the all ble wind u Lift pres u e f he system 5. CO DITIONS OF USE
installed i that part' lar area R fie allowable T e single-ply EPDM, PVC, and TPO roofing membranes
wind upliftpressures f systems as I sted,n Table 4.
described in this report comply with, or are suitable
5.6 The aIle ble wind u Ift press refs iste in Table 4 alfarnati es to what is specified in, those codes listed in
are fort roof cover' g syste do . 7h deck and Schon 8.0 of this report, subject to the follo�rring
framing which the system i la ach d must be conditio s:
designed r the appti ble com ars
in
and cladding
wind Ica in accorda �e with th a icat le code. See Sections 5.1 through 5.8, except revise Section 5.3 to
5.7 When pplicadon is overexisting roofs,
read as hollows:
docume(i ation of th wind-up!tt r sis nce of the 313 F plastic insulation muss be separated from the
compos roof const on mu b sub itted to the int for of the building by an approved thermal barrier
code o R ial for ap oval at the tiI n of permit in accordance with BNBC Section 2603.4.1.6, SBC
appli cat . Section 2603.5.1.5, and UBC Sections 2602.4 and
5.8 The roe g membran are ma u ure at Carlisle,
2 .5.3, as applicable.
Pennsy pia; Green le, Illinois; oil , Utah; and
Senato i Mississi i, unde a qu Ilty control
program with in pections fnderwriters
Laborat les Inc. {AA 8).
I � I
Nov 23 10 08:48a Suzy Rainey (510) 783-1041 p.5
1 �,�,
Cool R6of RatirgCouncil htip I/ cow- orroors.Ur 1 u -
Alltw P.rC;dt4, s
Rated Products 13 rectory:Sea ch Result [fir searcd]{print fr enmv vew
(last updated 11 Nov 2G1 1 23 CST) I
Showing Search Resol I r: i
cormany: a lisle SynTec tn:D�rr ated
Model• A ite IPO
select-from products v r compary_narre='Wlisle SynTec rc;orr 5ratbd nd modak'Whi;e TPCr cr er b compan narne aso
previous I 1 I next
(shoving records 1-1 of 1
25 Records per Pag
--
SRI
1 snit e9oct. T— l.'init� �PeAPPlicationl
CRRC
Prod.IDManutactu Information(sort +`Brand i odel Icotor Catonory,Prod ct o �i �L �.
clncor alert Spectro-� eltl tATP 'Bright Wit la SinglE Pip Tterrnnp 5cl O.BB pending i).89 pencfr�(r17�pe dingy Low9Stcep
r;�W
r17
Sy Pa
w L man45.7 1
previous{ 1 1 next
(showing records 1-" ) I
25 Records per Pa
i
I
Lout the CRR JP rcl,Ratirg,Programa Rated Produ a rectory I fW4 klemlr_rs ICRRC News
BPc tJl$mber I1 �o t 1 Conk G US o.1 Roof inks(Hnms
i
I � I
i
j
I '
I
I
i
i
t
I
I
I I I
I
I
I �
i
I
tI I
11/2312010 8:46 AM
o
f 1
INPUT Resources Energy IAQ/Health
. n oor rr ua rty an mis es
1.Use Low/No-VOC Paint 1 IAQ/Health pts y=yes 0
2.Use Low VOC,Water-Based Wood Finishes 2 IAQ/Health pts y=yes 0
3.Use Low/No VOC Adhesives 3 IAQ/Health pts y=yes 0
4.Use Salvaged Materials for Interior Finishes 3 Resource pts y=yes 0
5.Use Engineered Sheet Goods with no added Urea
Formaldehyde 61AQ/Health pts y=yes 0
6.Use Exterior Grade Plywood for Interior Uses 1 IAQ/Health pts y=yes 0
7.Seal all Exposed Particleboard or MDF 4 IAQ/Health pts y=yes 0
8.Use FSC Certified Materials for Interior Finish 4 Resource pts y=yes 0
9.Use Finger-Jointed or Recycled-Content Trim 1 Resource pts y=yes 0
10.Install Whole House Vacuum System 3 IAQ/Health pts y=yes 0
I 1 1
N.Flooring
1.Select FSC Certified Wood Flooring 8 Resource pts y=yes 0
2.Use Rapidly Renewable Flooring Materials 4 Resource pts y=yes 0
3.Use Recycled Content Ceramic Tiles 4 Resource pts y=yes 0
4.Install Natural Linoleum in Place of Vinyl 5 IAQ/Health pts y=yes 0
5.Use Exposed Concrete as Finished Floor 4 Resource pts y=yes 0
6.Install Recycled Content Carpet with Low VOCs 4 Resource pts y=yes 0
1 I I
Total Points Available: 1 1401 1301 57
Total Points Project Received: 1 01 0 0
G:daralprogs/greenbuildingguldelines remodelers/greenpointsfinal2.12.04protectedxls
ITT Of
CITY OF CUPERTINO
10 REROOF
+CUPE T'INO PERMIT APPLICATION
AP \3s 1 --Ie S 4. o� Date:
Building Address:
`Z i 7 40 G 2A,�J A DA /V C
Owner's Name: 3 6-t i F-t2e,r ciz-T,c 5 Phone#:
HOA: Yes ❑ No © If Yes, provide letter from HOA
L4Q9- 3?v
Contractor: 2` Go�+A Wlt-j2�(Utz Gt�Z I�. Phone#: 5/O LI i vz
1 �fZ75 GJ�c�'-� 3c.v�. Ss+� t-c,�-•�,��� �� S �7 Sl©• S4�f • �{12/
Fax#:
Cupertino BusinesA License #: Contractor License #:
Type of Roof Covering:
Existing: Proposed:
,k Built-Up Roof ❑ Built-Up roof
❑ Asphalt Shingles ❑ Asphalt Shingles
❑ Wood Shakes ❑ Wood Shakes
❑ Wood Shingles ❑ Wood Shingles
❑ Other(Specify) g Other(Specify) 6 cr-)
Number of existing coverings ❑ Provide I.C.C.E.S. Report# FS Z )141 3
❑ To be Removed ❑ Provide Mfgr. Installation Specs.
Job Description: e- z_ crT� �-R�s�,,,J 3 U jo JAJ 60 M,/
-Tpo eys-,Lyvl. 3S s y
Residential ❑ Commercial
Green Building: Please complete relevant portion of the Confirmed with Planning Dept. if
Green Building Checklist & attach it to the application or if there are any restrictions: ❑
applicable, include in plan set & the sheet index.
Valuation: q L4 ' en,
I Have Rea erstand and Will Comply with Cupertino's Tear-Off Policy:
Signature
Revised 02/05/09