Loading...
13050014 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 1228 YORKSHIRE DR CONTRACTOR:SOLARCITY PERMIT NO:13050014 OWNER'S NAME: ADAM SMITHLINE 3055 CLEARVIEW WAY DATE ISSUED:05/02/2013 OWNER'S PHONE: 4083484955 SAN MATEO,CA 94402 PHONE NO:(650)638-1028 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL 11 COMMERCIAL1 License Class' Lic.# e6 10 INSTALL 50 AMP CIRCUIT AND NEMA OUTLET Contractor Date I hereby affirm that I am liceed under the provisions of Chapter 9 (commencing with,Section 70 0)of Division 3of the Business&Professions Code and that.my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$300 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:36210015.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 1 AYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAY M LAST CALLED INSPE ION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the 2 granting of this permit. Additionally,the applicant understands and will comply Issued by: Date: with all non-point source regulations per the Cupertino Municipal Code„Section 9.18. RE-ROOFS: Signature dI Date / All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER 1,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sect* s25505,203 d 25534. Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized agent: Dater permit is issued., I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,.and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION fS 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 AE GUFERTtNO (408)777-3228•FAX(408)777-3333•buildinQc)cupertino.ong PROJECTADDRESS 1228 aY�A1111ire a✓I7 APNF LJ OWNER NAME A km �N'L• tpt'— PHONE �a•- [Q •Yq!F< E ►1i SNL f hHO�. STREET ADDRESS (/t CITY STATE Z�rl �j (/ r/ FAX 1228 Yovt�sti;�cr Dv. C� :� So/ CONTACT NAME 1�n c "C6")222 - 61353 E-,"J`nf`A+kUC,k @ srREEr ADDRESS 3 f ,��r C l `�'v CITY,STATE,ZIP I ^1 _ /' 1 Cf�4tP tkAX ❑OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT XCONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHTI•SCT ❑ENGINEER ❑ DEVELOPER ❑TENANT CONTRACTOR NAME D A t/I LICENSE NUMBER O LICENSE TYPE C 1 BUS.LIC a COMPANY NAME So �V i E-MAIL, d FAX •M' t� �p�c�-r G -C� STREET ADDRESSpt T t CITY,STATE ZIP _ Px0 650 678 !$q S 1-bS CI lV� $ OI ARCHTTECTIENGINEER NAME LICENSE NUMBER BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS, CrrY,STATE,ZIP PHONE USE OF *SFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE. ❑ Commercial URBAN INTERFACE AREA ❑ Yes ❑ No FLOOD ZONE ❑ Yes tvo ❑SOLAR PANELS ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER FOR SOLAR PANELS: NUMBER OF PANELS/UNrrS: KBAWATT'S(COMMERCIAL ONLY): TOTAL VALUATION: O DESCRIPTION OF WORK 1 V .- Yffig .bREY �FSD 1 a a y+k By my signature below,I certify to each of the following. I am the property owner or authorized agent to act on the owner's behalf.I have read this application and the information I have provided is corfecL I have rqq ption of Work and verify it is accurate. 160=to comply with all applicable local ordinances and state laws relating to build g nstruction i au ernatives of Cupertino to enter the above-identified property for inspection purposes. Signature of Applicant/Agent Date: /��l SUPPLERRqTAL INFORMATIOR REQUIRED PYApp 2011.doc revised 03116111 CITY OF CUPERTINO FEE ESTIMATOR-BUILDING DIVISION ADDRESS: 1228 YORKSHIRE DR DATE: 05/02/2013 REVIEWED BY: MENDEZ APN: BP#: *VALUATION: $300 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration/ Repair PRIMARY PENTAMATION USE: SFD or Duplex PERMIT TYPE: 1 REAP WORK INSTALL 50 AMP CIRCUIT AND NEMA OUTLET SCOPE . , ., maya . a. Nfech.Plan Check Plumb.Plan Check Elec.Plan Check 0.0 hrs $0.00 :Meeh. Permit Fee: Plumb.Permit Pee: Elect.Permit Fee: IEPERMIT Other Mech.Insp. _ Other Plumb Insp. L Other Elec.Insp. 0.0 hrs $45.00 ltlech. Insp.Fee: Plumb. Iusp.Fee: Elec.Insp,Fee: NOTE.This estimate does not include fees due to other Departments(i.c Planning,Public Works,Fire,Sanitary Sewer District,School District etc). These ees are based on the mina information available and are onlyan estimate. Contact the De t or addh7 info. FEE ITEMS(Fee Resolution 11-053 Eff. 7/1/12) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 = amps Electrical Suppl.PC Fee: (E) Reg. ® OT 0.0 hrs $0.00 $45.00 IBELEC2007 Services PME Plan Check: $0.00 Permit Fee: $0.00 Suppl.Insp.Feer Reg. Q OT 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $45.00 Consiruction Tax: Administrative Fee: IADAffN $42.00 Work Without Permit? 0 Yes (E) No $0.00 E) Advanced Planning Fee: $0.00 Select a Non-Residential E) Travel Documentation Fee: 1TR4VD0C $45.00 Building or Structure A Strong Motion Fee: IBSEISMICR $0.50 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 $133.50 $45.00 � $178.50 Revised: 04/29/2013 2' n � ' a r 9, (N) NEMA 14-50 Outleto a .- "' NE G7 FFIco L-.� 1450 ? O ,— O K <� F 5 O O O ; 4, r1 @' c 0 Finished Floor CE s a ,r acv 3 o cs ) U4�11 I 70 C Cj �� 0 -j O 7 rr.. ...r.-.' '( ` I �� Garage (E) 100A Main Electric Service = , s' ff E.( U -61 � O Z 2 _ L3 tcy) w #8 AWG TH WN-2 o I m `i''1)#10 AWG THWN-2 �— 314" EMT 25' 20' 1 314" Romex 15' ( (N)•NEMA 14-50 Outlet 1 W 2' 16' 2' Z Yorkshire Drive 3 Yorkshire Drive CONFIDENTIAL-THE INFORMATION HM JB-9501702-00 PREMED OMNN1t CONTAINED SHALL NOT BE USED FOR TK Cu Cupertino BENEFIT OF ANYONE EXCEPT SOLAWTY INC., Adam Smithline NOR SHALL IT BE DISCLOSED IN WHOLE ON IN 120/ �PA ���� 1228 Yorkshire Drive PART To OTHERS OUTSIDE THE RECIPIENTS 120 240V Branch Circuit 100A Cupertino,CA 95014 ORGANIZATION,EXCEPT IN CONNECTION PATH PROJECT MANAGER: MU VOLTAGE AIVERAGE:. p THE SALE AND USE OF THE RESPECTIVE James Winttuck 120124OV/50A (408)348-4955 6334 Arizona Place SOLARCITY EQUIPMENT,WITHOUT THE WRITTEN ORAFIEP.: DevMc adamsmithline@yahoo.com Los Angeles,CA e0045 PERMIWION OF sOIARCITY INC Dan Michalowicz NEMA 14-50 (888)-SOL-CITY(765-2489)www.soWrcitymm ELECTRIC PANEL 100A Main Service (1) 50A/2P CIRCUIT BREAKER FROM 120/240V SINGLE PHASE UTILITY SERHCE (E) LOADS OR MAIN PANEL NEMA 14-50 RECEPTACLE A I L1 LZ " " I EGO EGC _ — — — — — — — — — — — — — — — — L _ _ _ _ J (1)AWG#8,THWN-2, Black (1)AWG#8,THWN-2, Red (1)AWG#8,THWN-2,White Neutral (1)AWG#10,THWN-2,Green EGC (1)Conduit IGt; 3/4"EMT,3/4"Rome , • Vmp =240 VAC Imp = 40 AAC • (7 ft ell 4, CONHDENTIAL-THE NFORMAIRON HEREIN JB-9501702-00 "`t PRETiSE oTMlot CONTAINED SWILL NOT BE USED FOR 1HE Cu ertinoy BENEFIT OF ANYONE EXCEPT saaRan INC Adam Smithline , NOR SHALL IT BE DISCLOSED IN WHOLE OR IN MAIN PANET StRNCE RA1NG 120 240V Branch Circuit 100A 1228 Yorkshire Drive PART To OMS GUM THE REC�IENT'S Cupertino,CA 95014 &iarQq„� l OROAMZATION.EXCEPT IN CONNECTION WITH PROJECT MANAf;QC CRMT VOLTAGE AMPERAGE: P TME SAME AND USE OF 1HE RESPECTIVE (408)348-4955 6334 Arizona Place SOLARCITY ECURMEIIr,WITHOUT THE WRITTEN DRAFTER: Oe*c adamsmithline@yahoo.com Los Angeles,CA 90045 PERMISSION OF SOLARCITY INC Dan Michalowicz NEMA 14-50 (888)-SOL-CM(765-2489)wwwsoIaRity.wrn NEC 2008 220.83-Adding a Circuit to an Existing Dwelling Unit Square Feet: 2.200 Panel Breaker Rating 100 .A 1_1/1_2 240 Vac NEC 220.83(A)(1) "General lighting and general use receptacles...@ 3 voltlamperes per square foot as determined by 220.12" 2,200 square feet x 3w/sq ft 6,600 VA NEC 220.83(A)(2) Small appliance and laundry branch circuits @1500VA per 20 amp circuit Number of circuits x 1500= 4.500 VA NEC 220.83(A)(3) "The nameplate rating of the following:" NEC 220.83(A)(3)(a) "All appliances that are fastened in place,permanently connected,or located to be on a specific circuit." Refrigerator- 1,200 VA Freezer- n/a VA Disposal- 1,152 VA Dishwasher- 1,300 VA Trash Compactor- n/a VA Cook Top Hood- 750 VA Microwave- 1,560 VA Toaster- n/a VA Wine cooler- n/a VA n/a VA Clothes Washer- 1,200 VA Clothes Dryer.gas- n/a VA Sauna Heater n/a VA Steam Room n/a VA Treadmill n/a VA n/a VA Landscape lights n/a VA Hot Tub n/a VA Pool Pumps n/a VA n/a VA n/a VA n/a VA EVSE: Tesla NEMA 14-50R 9.600 VA 16,762 total VA NEC 220.83(A)(3)(b) "Ranges,wall-mounted ovens,counter-mounted cooking units" Range- 9,600 VA Oven - nia VA Cooktop- n/a VA n/a VA n/a VA 9,600 total VA NEC 220.83(A)(3)(c) "Clothes dryers that are not connected to the laundry branch circuit specified in item(2)" Dryer 1 - n/a VA Dryer 2- n a VA 0 total VA NEC 220.83(A)(3)(d) "Water heaters" Water Heater 1 n%a !A Water Heater 2 nia _ VA 0 total VA Total of non air-conditioning loads: 37,462 total VA First 8kVA of load at 100% 8,000 VA Remainder of load at 40% 11.785 VA Adjusted total of non air-conditioning load 19,785 VA NEC 220.83(B) "Where additional air-conditioning equipment or electric space-heating equipment is to be installed..." A/C Equiprpent Unit#1 n/a VA A/C Equipment Unit#2 n/a VA A/C Equipment Unit#3 n/a VA A/C Equipment Unit#4 n/a VA A/C Equipment Unit#5 n/a VA A/C Equipment Unit#6 n/a VA Total of A/C Loads and All Other Loads: 19,785 total VA Total Proposed Calculated Load: 82.44 Amps JB - 9501702 -:_�SolarCity ©copyright SolarC ty 2013 4 a'Aea ticeoois i f i Nom 3894 o iS 12VM Fruth Mtunt V 4W ss��isar�irsT�� a®o = ALIrrU 1 75*C M*Ncmm 1 PC 7 5 079 s nCD f ,, Q CL— is Q n n CA �ry L f tP 4 wt li it Q naa tiL£00lS Ql'9'd Z' 3894 o C5 RUSK MouRt 3P 4W AL CU QC�►n�e°i,u. 75*C SYr.W1m1 wa.r�cnw NB7 t " y 7 5 � 79 s ,,��• a-, �" r.. H ' Q Q A A N H 0 .r. Q CA . t