13050019 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 21091 RAINBOW DR CONTRACTOR:SOLARCITY PERMIT NO:13050019 OWNER'S NAME: MARTY GUNTHER . . 3055 CLEARVIEW WAY DATE ISSUED:05/03/2013 OWNER'S PHONE: 4088882407 SAN MATEO,CA 94402 PHONE NO:(650)638-1028 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL D COMMERCIAL° License Class G` (e. Lic.# `6'61 I(9N �t INSTALL 21 ROOF TOP FLUSH MOUNTED SOLAR PANELS, Contractor S 0 taxi 4-7 Date C--/VIT 5.145KW,ELECTRICAL UPGRADE 200 AMP I hereby affirm that,I am licensed under the provisions of Chapter 9 . (commencing with.Section 7000)of Division 3 of the Business.&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a'certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the , perfonnance of the work for whichthis permit is issued, Sq.Ft Floor Area: Valuation:$22000 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:36223052.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIN : i 5 • YS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter �I M LAST CALLED INSP TION. upon the above mentioned-property for.inspection purposes. (We)agree to save 180 DAY indemnify and keep harmless the City of Cupertino against liabilities,judgments, /� costs,and expenses which may accrue against said City in consequence of the Issued by: Date: granting of this permit, Additionally,the'applicant understands and will comply with all non-point sour,..- per the Cupertino Municipal Code,Section / 9.18. RE-ROOFS: Signatu �'� Date 3 All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. 0 OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two.reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the.structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: 1 ' `! Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sect'..= :,25533,and 25534. Section 3700 of the Labor Code,for the performance of the work for which this ' el/i 3 Owner or authorized age /&_ Date: permit is issued. / I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If,after making this certificate of exemption,I become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT'CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this:permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18, Signature ' pate . a , 1 \r/� ALTERNATIVE ENERGY PERMIT APPLICATION V' COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION 4J.tflSO 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 AE 4,-.- URERTINO (408)777-3228 • FAX(408)777-3333 •buiidinq(a-cupertino.orq \(A PROJECT ADDRESS ilj Al 6 q 1 Kiii wiion,0 Ar, 1 _ Z -6S- * OWNER NAME hi 4/7...4.,/• au0til ///"��� / 1-PHONEV/ �� 4 ^AIJotMA,AAl�1 ,(�/►�{ulvl C// @ cG.cri STREET ADDRESS (/ ( U YV bis• CITY Sm er+ O Z q so i/'F//JAX" el- /,___6,to l �� 1n �� I Y CONTACT NAME 1444 t w <JC/a _„/�; /) PHONE E-MAIL STREET ADDRESS ( /� CITY,STATE, ZIP FAX ❑ OWNER 0 OWNER-BUILDER 0 OWNER AGENT J1�t CONTRACTOR 0 CONTRACTOR AGENT 0 ARCHITECT 0 ENGINEER 0 DEVELOPER ❑ TENANT CONTRACTOR NAME/4.z))) �s �"cc h �J(��� LICENSE NUMBER?V/e v LICENSE TYPEC t /6 BUS.LI i /y COMPANY NAME //I`i JCL E' I ZS 0 `� VC 5 -Z12--1° Z-/Q STREET ADDRFS f J C !L/Y ! 19d, �V o t C 51 / ! , ( HIL / <o yl IJV-Y 3-q 3,//�' ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC 0 COMPANY NAME - E-MAIL FAX STREET ADDRESS I CITY,STATE,ZIP PHONE USE OF gSFD or Duplex 0 Multi-Family .PROJECT IN WILD LAND PROJECT IN STRUCTURE: 0 Commercial URBAN INTERFACE AREA 0 Yes 0 NO FLOOD ZONE 0 Yes 0 NO I �/ jIQ SOLAR PANELS 0 ELECTRIC VEHICLE CHARGING STATION 0 SOLAR WATER HEATING 0 OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS. gy J KILOWATTS,_ cI/ TOTAL VALf:A�TOyI �` L _ r I/�l CJ��f%` `/'747/1 DESCRIPTION OF WORK( .. Z vt_s-1-41/ 21_ re,Jf-- - /vs win/44,-- , __ ,Ia..4,- p.6frfrids Zfs , Pfs-i‹w) . ut1,--,d( , e_i_,/ 6 .. .),v--r ' crf ,210.— 414ts RECE. DB By my signature below,I certify to each of the following: I amt • property.weer or authorize agent to act on the pr per4 owner's behalf. T have read this application and the information I have pro ded is .rrect. I have cad the D-scription ofWor nd verify it is accurat . ee to comply with all applicable local ordinances and state laws relating to buil..' :co i. ction. ;aut 1 rize repr sentatives of Cu rtmo to enter the above-i.-, fi-d property for inspection purposes. Signature of Applicant/Agent: / i!I / Date: a /3 SUP' EMENTAL INF n' •TION REQUIRED - .',--..1 OrFcCE .Y : OVER TIIE•COUNTER F : _Q EXPRESS rJ . • - - ❑r STANDARD z -- S , ❑'LARGE 4 • 0 MAJOR PVApp_2011.doc revised 03/16/11 CITY OF CUPERTINO �'`` iv FEE ESTIMATOR-BUILDING DIVISION ADDRESS: I DATE: 05/03/2013 REVIEWED BY: Mendezt1 !}K•"3 APN: IBP#: *VALUATION: 1$22,000 *PERMIT TYPE: Building Permit I PLAN CHECK TYPE: Alteration/ Repair PRIMARYI I PENTAMATION SOLAR-RES USE: SFD or Duplex PERMIT TYPE: i WORK install 21 roof top flushmounted solar panels, 5.145kw, electrical upgrade 200 amp SCOPE yi flip /Meeh.Plan Check. I Plumb.Plan Check Elec.Plan Check 0.0 hrs $0.00 I. Lteclr. Permit Fee: Plumb.Permit Fee: Elec.Permit Fee: IEPERMIT Other Mech.In.sp. 1---- Other Plumb In,sp. Other Elec.Insp. 0.0 hrs $45.00 11echc In.sl�.LE Plumb. InFee: Plec.Insp.Fee: . : T NOTE:This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc.). These fees are based on the preliminary information available and are only an estimate. Contact the Dept for addn'1 info. FEE ITEMS (Fee Resolution 11-053 E ' 7/1/12) FEE QTY/FEE I MISC ITEMS Plan Check Fee: $0.00 ( 1 ( # Alternative Energy System Suppl.PC Fee: a Reg. 0 OT 0.0 hrs $0.00 $219.001 1PHOTOVRES I Photovoltaic System u PME Plan Check: $0.00 1200 I amps Electrical Permit Fee: $0.00 $45.00IIBELEC200 I Services Suppl.Insp.Fees Reg. 0 OT 10.0 hrs $0.00 PME Unit Fee: $0.00 I I PME Permit Fee: $45.00 Construction Tax: I Administrative Fee: IADMIN $42.00 Work Without Permit? ® Yes Q No $0.00 I I Advanced Planning Fee: $0.00 Select a Non-Residential 0 I I Building or Structure � Travel Documentation Fee: ITRAVDOC $45.00 A Strong Motion Fee: 1BSEISMICR $2.20 Select an Administrative Item Bldg Stds Commission Fee: 1BCBSC $1.00 264.00 ,��,; � -} $399.20 Revised: 04/29/2013 / t -, Building Department V . - '..- City Of Cupertino 10300 Torre Avenue �S -c.I 9, Cupertino,CA 95014-3255 CUPERTINO = Telephone: 408-777-3228 Fax: 408-777-3333 CONTRACTOR/SUBCONTRACTOR LIST . //9JOB ADDRESS: �, I�} / M�c1 /`, PERMIT# � 6 OWNER'S NAME: ,�/� ^( Vrt l PHONE# �1 -- cC—� d 5 GENERAL CONTRACTOR: / 6/ q�^�/ BUSINESS LICENSE .. - ADDRESS: zq r 5 a CITY/ZIPGODE:' 5 /j' Y�0Y *Our municipal code requires all busine ses working in the city to have a City of Cupertino business cense. NO BUILDING FINAL OR FINAL OCCUPANCY IN PECTIO (S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRA li ORS ,VE OBT, NED'A°`CITY OF CUPERTINO BUSINESS LICENSE. / . / I am not using any subcontractors: if .er 1.,1 ei Sig i ure Date Please check applicable subcontractors and comple e the following information: // SUBCONTRACTOR BUSINESS NAME ' BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring/Carpeting • Linoleum/Wood Glass/Glazing Heating Insulation Landscaping Lathing Masonry Painting/Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile , '-81'11, 1,., , I i ..-.' / , Ow Contractor Signature Date • ABBREVIATIONS ELECTRICAL NOTES INDEX LICENSE JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING PV1 COVER SHEET CA # 888104 FLASHING WILL BE PAINTED TO MATCH PV2 SITE PLAN - AC MEANS MAY BE ENERGIZED IN THE OPEN C-46, C 10 ALTERNATING CURRENT POSITION, A SIGN WILL BE PROVIDED WARNING PV3 STRUCTURAL VIEWS EXTERIOR BLDG BUILDING OF THE HAZARDS PER ART. 690.17. PV4 ADDITIONAL DETAILS CONC CONCRETE PV5 ADDITIONAL DETAILS Installing 21-roof top flush-mounted panels C COMBINER BOX 2. EACH UNGROUNDED CONDUCTOR OF THE D DISTRIBUTION PANEL MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PV6 VENT SPANNING DETAIL for total of 5.145 kW DC. Upgrade Electrical BY PHASE AND SYSTEM PER ART. 210.5. PV7 UPLIFT CALCULATIONS Service to (N) 200-Amps DC DIRECT CURRENT 3. A NATIONALLY-RECOGNIZED TESTING PV8 THREE LINE DIAGRAM EGC EQUIPMENT GROUNDING CONDUCTOR PV9 ELECTRICAL CALCULATIONS APN#362-23-052 (E) EXISTING LABORATORY SHALL LIST ALL EQUIPMENT IN EMT ELECTRICAL METALLIC TUBING COMPLIANCE WITH ART. 110.3. Cutsheets Attached G SOLAR GUARD METER 4. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(B) COMMUNITY DEVELOPMENT GALV GALVANIZED D BUILDING DMSION DEPARTMENT GROUNDINGELECTRODECONDUCTOR5. DC CONDUCTORS EITHER DO NOT ENTER -CUPS GEC CUPERTINO GND GROUND BUILDING OR ARE RUN IN METALLIC RACEWAYS GENERAL NOTES APPROVEp OR ENCLOSURES TO THE FIRST ACCESSIBLE DC HDG HOT DIPPED GALVANIZED is set of plans and specifications MUST be kept at the DISCONNECTING MEANS PER ART. 690.31E I CURRENT 1. THIS SYSTEM IS GRID-INTERTIED VIA A b site Burin construction, it is unlawful to make Imp CURRENT AT MAX POWER 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN UL-LISTED POWER-CONDITIONING INVERTER. changes or alterations on any „%. RELIEF AT ALL ENTRY INTO BOXES AS same, or to deviate �;, � CUPERTINO INVS INVERTERS erefrmpd without a , Isc SHORT CIRCUIT CURRENT REQUIRED BY UL LISTING. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. pproval from the Building Official. Building Department kVA KILOVOLT AMPERE 3. PHOTOVOLTAIC SOURCE AND INPUT CIRCUITS AStamping this plan and I =� 7. MODULE FRAMES SHALL BE GROUNDED AT THE a Sta in kW KILOWATT UL-LISTED LOCATION PROVIDED BY THE INVERTER INPUT CIRCUIT ARE UNGROUNDED. b' held to permit or to be an pecifications SHALL NOT - TAY 2013 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDS approval of the violation LBW LOAD BEARING WALL MANUFACTURER USING UL LISTED GROUNDING 9 any 'rovisions,of MIN MINIMUM HARDWARE. 5. ALL WORK TO BE DONE TO 2010 CALIFORNIA any City Ordinance or State Law, :REVIEWED FOR CODE COMPLIANCE MIR MIRROR 8. ALL EXPOSED METAL PARTS (MODULE FRAMES, BUILDING CODE. BY y I (N) NEW RAIL, BOXES, ETC.) SHALL BE GROUNDED USING 6. ALL ELECTRICAL WORK SHALL COMPLY WITH DIE 101 I.2 2008 NATIONAL ELECTRIC CODE AS AMENDS Reviewed By � � �j�. � NEC NATIONAL ELECTRIC CODE UL LISTED LAY-IN LUGS LISTED FOR THE THE 2010 CALIFORNIA ELECTRIC CODE. IT NO.— S66 NIC NOT IN CONTRACT PURPOSE. POSTS SHALL BE MADE . NTS NOT TO SCALE ELECTRICALLY CONTINUOUS WITH ATTACHED OC ON CENTER RAIL. PLOT PLAN8 P PANEL BOARD 9. MODULE FRAMES, RAIL, AND POSTS SHALL BE PL PROPERTY LINES BONDED WITH EQUIPMENT GROUND CONDUCTORSCRECKED BX PV PHOTOVOLTAIC AND GROUNDED AT THE MAIN ELECTRIC PANEL. PVC POLYVINYL CHLORIDE 10. THE DC GROUNDING ELECTRODE CONDUCTOR VICINITY MAP DAA /�'�� S SUBPANEL SHALL BE SIZED ACCORDING TO ART. _ rArgif SCH SCHEDULE 250.166(B) & 690.47. r " ' SS STAINLESS STEEL 1 ' fir„°, - .r TIE.UMW- ;tom ,a ,. PLA G DE)1 Ikestone Dr = °b , � ,� ._+ ,� SSD SEE STRUCTURAL DRAWINGS 1 Indell'VVa x ' - 4.4 ' . , :, ,t STC STANDARD TESTING CONDITIONS ^`` y �"• � . SWH SOLAR WATER HEATER ,."p ,. ", _ - "4 c,'.. r ...:ii,, a , _ Three *~ - TYP TYPICAL ; I r .r .-., .+R, UON UNLESS OTHERWISE NOTED .. ' r � ' "` '� A WOG. O>or. Berl'krtapypr �n+�Irehill Ct ��►.Oaks Park, UPS UNINTERRUPTIBLE POWER SUPPLY �• '" '" • I is rr V VOLT aw,s.• .• D`- w _ AAti f Vmp VOLTAGE AT MAX POWER • - 17 I ,..,� 4 . w j r -�1 Shadowhili'Lr! ,'' Voc VOLTAGE AT OPEN CIRCUIT K" a t , ►r ,Rambo+r% : :..' :. ' - ill ._M .w 3i_1'_M ,y;{ .. . . ., ; W WATT - - - woo C .. AritatleMlid - 3R NEMA 3R, RAINTIGHT1. - 11 Ral n l' � it... � q6 .� Tom. v (• i �# ,�� +► (D - �SQrange Blossam'Df REV BY DATE COMMENTS p _ '"4", 44,4 '', 4 /� !", .. 1,d= ate �c R w ��4/29/2013 COMMENTS • i ,- ,� , gi F4reri e; ,1 . : d .«at Sure Y; . r�-n Serroi ,yger ©©© J B-9 501717 00 PREMISE OWNER: AHJ: DESCRIPTION: DESIGN: CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: DSEBA �,•„,!' CONTAINED SHALL NOT BE USED FOR THE GUNTHER, MARTY GUNTHER RESIDENCE .��, $D�a�� BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: � trY NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI 21 TRINA SOLAR ; TSM-245PC05 PA05.1. 21091 RAINBOW DR 5.145 KW PV Array I ORGANIZATION,PART TO RS EXCEPTIDE THE IIN CONNECTIIPIENT'SON WITH PROJECT MANAGER: MOUNTING SYSTEM: • CUPERTINO, CA 95014 , /� THE SALE AND USE OF THE RESPECTIVE S+P ST 3055 Oearvew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. PAYMENT TYPE: INVERTER: 4088882407 4/29/2013 T:(650)638-1028 F:(650) 638-1029 PPA POWER-ONE # AURORA PVI-4.2-OUTD-S- S COVER SHEET PV 1 (666)-SOL-OTY(765 2489)www.solarcity.cam yam F PITCH: 23 ARRAY PITCH:23 MP1 AZIMUTH: 180 ARRAY AZIMUTH: 180 MATERIAL: Low Profile W-Tile STORY: 2 Stories 1. 'Kt,,.., • it?,;:.. ;\;:a: ..°49) 2,:t. Ir._, . ,, , �� icm.,.� UPERTINO - r,, ; I,. I d Idinc Department. u_ ; p; 15 to PL VIvil t� (.9 ' iri're9e .mo) . Y _-- u REVIEW'E'D FOR COLE COMPLIANCE _ii Reviewed B' 5.45,,, ,2--157e,-/74 D LEGEND O (E) UTILITY METER & WARNING LABEL ® INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS 15'to PL • < DC 1. 4-I DC DISCONNECT & WARNING LABELS • _ I I �-1 AC DISCONNECT & WARNING LABELS _ _ 3'Fire Setback tc M P 1 I L ' I 1_, 0 JUNCTION BOX B i PV3 77 o IT O DC COMBINER BOX & WARNING IJ �' 0 DISTRIBUTION PANEL & WARNING 15'to PL 0 < - > I •, I LG LOAD CENTER & WARNING LABELS oc cFence ed Gated 9Jn-Cockgd G`a:ed Ffynce i " I ° " ° ° ° O DEDICATED PV SYSTEM METER A '� — CONDUIT RUN ON EXTERIOR PV3 i 4•1115WA 25'to PL CONDUIT RUN ON INTERIOR — GATE 21091 Rainbow Dr I -- NTERIORNCE EQUIPMENT l I >,,f SITE PLAN N ,..��%���,, Front Of House '. '►,., Scale: 1/8" - 1'0 1' 8' 16' w 111111 j E msmil CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J B-9501717 00 PREMISE OWNER: AHJ: DESCRIPTION: DESIGN: -*ka4/ CONTAINED SHALL NOT BE USED FOR THE GUNTHER, MARTY GUNTHER RESIDENCE DSEBA �; ,, BENEFIT OF ANYONE EXCEPT SOLARCITY WHOLE INC., MARKET: MODULES: '„ Solar��ty NOR SHALL IT BE DISCLOSED IN WHOLE 1 IN REST (21) TRINA SOLAR # TSM-245PC05/PA05.18 21091 RAINBOW DR 5.145 KW PV Array o PART TO OTHERSOUTSIDEI THE RECIPIENTS PROJECT MANAGER: MOUNTING SYSTEM: C U P E R TI N O CA 95014 3055 Clean/leo Way ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE S+P ST SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: Son Mateo, CA 94402 PERMISSION OF SOLARCITY INC. PAYMENT TYPE: INVERTER T:(650)638-1028 F:(650)638-1029 PPA POWER-ONE # AURORA PVI-4.2-OUTD-S-JS 4088882407 SITE PLAN PV 2 4/29/2013 (888)-SOL— PAYMENT Y(ass 248s>www.soIorclty.com (E) 2x4 TOP CHORD MODULE 6" OFF © 24" O.C. / 4' / ROOF DECK. (E) 2x4 RIDGE BOARD (BLOCKING) \ I i i t \ 0 / (E) 2x3 '_. i )J vi -" I �> " � 2' ®E) 2x4 TOP 24" SPACING CHORDS -10 6-10 / 5-10 / (E) 2x4 BOTTOM 1 (E) LBW CHORD ® 24" O.C. TOP CHORD: 2x4 FRONT VIEW OF MP1 SUPPORT: 2x4, 2x3 WEB B SCALE: 1/2" = 1' MAX SPAN: 6'-10" TC GRADE: NO.1 SIDE VIEW OF MP1 A SCALE: 1/4" = 1' • I . �� CUPERTINO INSTALLATION ORDER I "If'� =2B:;ilding Department ZEP SPANNER BAR LOCATE RAFTER, MARK RAFTER I - -0 (6) LOCATION, AND REMOVE TILE. {rpt„ ge",':" : 2J13 (1) PLACE STANDOFF BASE & DRILL _Yv _� ?: ---- PILOT HOLES AT THE RAFTER REVIEWED FOR CODE COMPLIANCE / ��� LOCATION. ,/ Ill �w• Rev,ewed 3y' ,_.5. 4.4 /`7AT i" DIA BOLT & NUT - •- 2) CLEAN PAPER AROUND PILOT (7) HOLE. ZEP SPANNER ����••�.. (3) "� BAR CLAMP �'plie �� ADJUST STANDOFF TO BATTEN I EC �� `ice HEIGHT. STANDOFF • (E) TILE SEAL PILOT HOLES AND BOTTOM U (4) OF STANDOFF WITH POLYURETHANE (E) ROOF DECKING (5) (4) SEALANT. 5/16" DIA LAG BOLT 0 LAG STANDOFF INTO RAFTER. (2-1/2" EMBED, MIN) LOWEST MODULE SUBSEQUENT MODULES (E) RAFTER (,) NOTCHAROUNDST NDOFTILE WEATHERING TO FIT STANDOFF Scale: 1 1/2" = 1' �) REINSTALL TILE. CONFIDENTIAL- NE INFORMATION HERON JOB NUMBER: J B-9501717 0 0 PRASE OWNER: Kt DESCRIPTION. I DESIGN: '014 CONTAINED SHALL NOT BE USED FOR NE GUNTHER, MARTY GUNTHER RESIDENCE DSEBA ..... �. BENEFIT LL ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES •Fi SO�arCity PARTS TO OTIT BE HERS OUTSIDENERECIPIENiT'SIN REST (21) TRINA SOLAR TSM-245PCO5/PA05.18 21091 RAINBOW DR 5.145 KW PV Array i, ORGANIZATION, EXCEPT IN CONNECTION WITH PROJECT MANAGER: MOUNTING SYSTEM: CUPERTINO, CA 95014 4(, ,- 3055 Marvin ray THE SALE AND USE OF THE RESPECTIVE S+P ST San Mateo,CA 94402 SOLARCITY EQUIPMENT,WITHOUT THE WRITTEN PAYMENT TYPE: INVERTER: PAGE NAME SHEET: REV: DAIS T:(650)638-1028 F.(650)638-1029 PERMISSION OF SOLARCITY INC. PPA POWER-ONE # AURORA PVI-4.2-OUTD-S-JS 4088882407 STRUCTURAL VIEWS PV 3 4/29/2013 (888)-SGL-CITY(765-2489)www.soIarcIty.com NEC 2008 220 82 - Residential Load Calculation Version 2.1 • L1L2 240 V NEC 220.82(B) 'The general calculated load shall be not less than 100% of the first 10 kVA plus 40% of the remainder of the following loads " NEC 220.82(B)(1) The calculated floor area shall not include open porches garages or unused spaces Floor Area 3.540 square feet x 3VA/sq ft 10,620 VA NEC 220.82(B)(2) "1500 volt-amperes for each 2-wire. 20-ampere small appliance branch circuit and each laundry branch circuit . " Small Appliance Circuits 6 circuits x 1500VA.circuit 9.000 VA Laundry Circuits 2 circuits x 1500VA circuit 3.000 VA Bathroom Circuits 2 circuits x 1500VA'circuit 3.000 VA NEC 220.82(B)(3) "i he nameplate rating of all appliances ranges ,+,all-mounted ovens counter-mounted cooking & 220.82(B)(4) units . clothes dryers that are not connected to the laundry branch circuit._ [and] water heaters" 2P Breaker VA Oven 40 7.680 Stove 30 5,760 Dryer 30 5.760 0 0 0 0 . 0 0 0 0 19,200 total `VA. Total of non air-conditioning loads 44,820 total VA. ;w � u��R�v)l First 10 kVA.of load at 100% 10.000 Sr r:.1 + 9 parnent Remainder of load at 40% i ''w_�.'.;,.,- 13 925 � � ': 1 C .�;is � _S , Adjusted total of non air-conditioning load 23,928 VA. ��t;, 013 NEC 220.82(C) "Heating and air-conditiong load '?IEViEIVEID FOR CODE COMPLIANCE 2P Breaker VA RE;viawe o By $soi .44-76-"V Sum of A/C Equipment Units 90 17280 Sum of Electric Furnaces 0 0 Total of NC Loads and All Other Loads 41,208 total VA Total Proposed Calculated Load 171.70 Amps JB - 9501717 l'ii' Solariet y • e copyright SolarCity 2013 CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: J 3_9501717 00 PREMISE OWNER: AHJ DESCRIPTION: DSEBA `1, r CONTAINED SHALL NOT BE USED FOR THE GUNTHER, MARTY GUNTHER RESIDENCE :'; ,. BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKET: MODULES: ��, Soiartity IC NOR SHALL IT BE DISCLOSED IN WHOLE OR IN REST (21) TRINA SOLAR # TSM-245PC05/PA05.18 21091 RAINBOW DR 5.145 KW PV Array ty ORGANIZATION, XCPART TO OTHERS OEPTIDE THE RECIPIENT'S IIN CONNECTION WITH PROJECT MANAGER: MOUNTING SYSTEM: CUPERTINO, CA 95014 dater--.24461 THE SALE AND USE OF THE RESPECTIVE S+P ST 3055 MateCleao, CA Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: San Maieo, CA 94402 PERMISSION OF SOLARCITY INC. PAYMENT TYPE: INVERTER: 4088882407 4/29/2013 T:(650) 638-1028 F:(650) 638-1029 PPA POWER—ONE # AURORA PVI-4.2—OUTD—S—JSLOAD CALCULATIONS PV 4 (888)—SOL—CITY(765-2489) www.solorciiy.com UPLIFT CALCULATIONS 04.29.2013 Version#9.4 SolarCity Wind Uplift Calculator Project Information Risk Category II PV System Type SolarCity SleekMount"" Spanish Tile Roof Spanish Tile Roof Layers(Comp Roof Only) NA Roof Slope 23° Rafter Spacing 24"O.C. PV Module Orientation Landscape Total Area of Array 370 sf PV Module Width 3.3 ft PV Module Length 5.4 ft Attachment Type Si-P ST Ground/Roof Snow Loads Ground Snow load pg 0.0 psf ' ASCE Table 7-1 Roof Snow Over PV Modules ps-pv 0.0 psf Surrounding Roof Snow ps-roof 0.0 psf v Wind Design Criteria Wind Design Code 0 ASCE 7-05 Wind Design Method 0 Partially/Fully Enclosed Method Basic Wind Speed V 85 mph Fig.6-1 Exposure Category 0 C Section 6.5.6.3 Roof Style 0 Gable Roof 'Fig.6-118/C/D-14Aj8 Mean Roof Height h 1 22 ft Section 6.2 Least Horiz.Dim.of Building LHD 32 ft Effective Wind Area(1 Module) A 17.6 sf IBC 1509.7.1 _Roof Wind Zone Width a 3 ft Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.92 Section 6-3 Topographic Factor Kzt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Section 6-4 Importance Factor I 1.0 Table 6-1 Velocity Pressure qh qh = 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 14.5 psf Wind Zone Interior(Zone 1) Ede Zone 2) Corner(Zone 3) r-"`""y C g r vUPERTINO Ext.Pressure Coefficient(Up) GCp(Up) -0.9 -1.6 -2.5 Fig.6-118jC./D-14?r6 iJ Ext.Pressure Coefficient(Down) GCp(Down) 0.5 0.5 0.5 Fig.0 116'C!D l4A/B I . /i Building Department Design Wind Pressure p p= qh(GCp) Equation 6-22 � Wind Pressure Up p(up) -12.7 psfJ -22.8 psf -35.5 psf i1 MAY �1 3 2013 I�•�`�:�� 4 U � u Wind Pressure Down p(down) 10.0 psf 10.0 psf 10.0 psf t_ Tile Allowable Attachment Spacing (In.) And Tributary Area (Ft^2) R.EVIEW`D FOR CODE COMPLIANCE Interior(Zone 1) Edge(Zone 2) Corner(Zone 3)I Max Allowed Foot X-Spacing Landscape 72" 48" 24" 39" Reviewed By 5�� •9TH Max Allowed X Cantilever Landscape 24" 18" 11" Max Standoff Tributary Area TribCL 20 sf 13 sf 7 sf PV Assembly Dead Load WPV 3 psf 3 psf 3 psf DLPV PCL 59 lbs 39 lbs 20 lbs WLUP-0.6 DLPVcos(B) TCL -247 lbs -297 lbs -231 lbs • Attachment Uplift Capacity Tallow 350 lbs 350 lbs 350 lbs TCL/Tallow DCRLand 70.6% 84.7% 65.9% CONFIDENTIAL - THE INFORMATION HEREIN JOB NUMBER: J3-9501717 0 0 PREMISE OWNER: AHJ: DESCRIPTION: DESIGN: `%44f# CONTAINED SHALL NOT BE USED FOR THE GUNTHER, MARTY GUNTHER RESIDENCE DSEBA �; ,, BENEFITRL IT ANYONE EXCEPT SOLARCITY* LEINC.,R MARKET: MODULES: "'ieSolarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI (21) TRINA SOLAR # TSM-245PC05/PA05.18 21091 RAINBOW DR 5.145 KW PV Array PART TO OUTSIDE THE RECIPIENT'S PROJECT MANAGER: MOUNTING SYSTEM: CURER TI N O, C A 9 5014 oafte,,Zetse. - ORGANIZATION11ON,, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE S+P ST 3055 Clearview Woy SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. PAYMENT TYPE: INVERTER: 4088882407 4/29/2013 T:(650)638-1028 F:(650)638-1029 PPA POWER-ONE # AURORA PVI-4.2-OUTD-S-USUPLIFT CALCULATIONS PV (888)-SOL-CITY(765-2486) www.solarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD (N)N 200A MAIN SERVICE PANEL Inv 1: DC Ungrounded INV 1 —(1)POWER—ONE 1 AURORA PVI-4.2-0U1D—S—US —(21)TRINA SOLAR 1 TSM-245PC05/PA05.16 CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP 200A/2P MAIN CIRCUIT BREAKER Inverter, 4200W,240V,96% PV Module; 245W,222.9W PTC,40MM,Black Frame C-46, C-10 Voc: 37.3 Panel Number:TBD INV 2 Vpmax:30.7 Meter Number:1005610852 *MODULE CURRENT RATINGS ARE SHOWN AS Isc AND Imp IN Underground Service Entrance INV 3 THE DC STRINGS IDENTIFIER OF THE SINGLE LINE DIAGRAM. MAIN SERVICE PANEL Inverter 1 IND 200A/2P 3 POWER—ONE x DC+DO NOT ADJUST MIN.ACTIVATION V TAGS (E) LOADS AURORA PVI-4.2—OUTD—S I US I EGC 1 String(s)ng(s)Of 9 On MPI J / —I • (� L1 210v I— V I L2 GFP/GFCI•� DC+ I1 niN �'�� DC 12 DO NOT/ADJUST MIN.ACTIVATION V TAGE (N)25A/2P EGC/ _ .� DC+ DC+ A r— GEC —+_ DC_ DC- 1 String(s)Of 12 On MP 1 BI • I GND, I EGC L EGC J I T`ILr (1)Conduit Kit; 3/4'EMT N — EGC/GEC rn- Z—Z C.9 — -E--- GEC TO 120/240V SINGLE PHASE UTILITY SERVICE i III ILIPERTIN ( 1 Building Department 1 � '; i § �r 3 REVIEWED FOROD CE CON)PLiANCE Reviewed By j;.,/../ ltire,,/ POIf—(1)Ground Rod; 5/B'x B',Copper AC • DC • (1)AWG/10, THWN-2,Black (2)AWG/10, PV HARE,Black Voc =335.7 VDC Isc =8.47 ADC O §—(1)AWG#10, 1HW4-2, Red 1:4—(1)AWG#8,Solid Bare Copper EGC Vmp =276.3 VDC Imp=7.98 ADC • (1)AWG/10, THNM-2, White NEUTRAL Vmp =240 VAC Imp=20 AAC (1)Conduit Kit; 3/4'EMT —(1)AWG#8, THWN-2,Green EGC/GEC —(1)Conduit Kit 3/e EMT (2)AWG#10, PV HARE,Black Voc =447.6 VDC Isc =8.47 ADC O §I-(1)AWG f8 Solid Bare Copper EGC Vmp =368.4 VDC Imp=7.98 ADC (1)Conduit Kit; 3/4'EMT CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-9501717 0 0 PREMISE OWNER AHLt DESCRIPTION: DESIGN: '1,441/„' CONTAINED SHALL NOT BE USED FOR THE GUNTHER, MARTY GUNTHER RESIDENCE DSEBA 117-;41 ., BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MARKER MODULES NOR SHALL IT BE DISCLOSED IN WHOLE OR IN RESI (21) TRINA SOLAR # TSM-245PC05/PA05.18 21091 RAINBOW DR 5.145 KW PV Array � ui 'ty PART 70 OTHERS OUTSIDE THE RECIPIENTS # ° ^ ORGANIZATION,EXCEPT IN CONNECTION WITH PROJECT MANAGER MOUNTING SYSTEM: CUP E R TI N O, C A 95014 3055 aearview Way THE SALE AND USE OF THE RESPECTIVE S+P ST San Mateo,CA 94402 SOLARCI1Y EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV DAIS PERMISSION OF SOLARCITY INC. PAYMENT TYPE: INVERTER: 4088882407 4/29/2013 L(65o)636-1028 f:(650)638-1029 PPA POWER—ONE # AURORA PVI-4.2—OUTD—S—JS THREE LINE DIAGRAM PV 8 (888)—SOL—CITY(765-2489)�nnr.$�areHyeam 1. Conductor Sizing per Art 690.8(A) ELECTRICAL CALCULATIONS deg.Conductor must have 30 deg. C ampacity >= 125% of continuous Current. Module: 21 TRINA SOLAR#TSM-245PC05 222.9 Inv Power WPTC Voltage Drop Calculations Version 5_8.0 Jake Tornatzky Inverter 1: 1 Power-One PVI-4.2-S 0.96 4800 4493.66 Vdrop= Imp) * (2*Length)*(Resistance) / (Vmp) * b. Conductor must have (after corrections for conditions of use) >= Module: Imp(A) Max.Length(ft) Wire continuous current per Table 310.15(B)(16). Inverter 2: String: 7.98 100 AWG_10 at Max Ave Hi:84 deg F Module: Vdrop= (7.98 *200 *0.001240hms) 1333.9264 0.59 Inverter 3: Branch: 7.98 I 0 I AWG_10 I at Max Ave Hi:84 deg F c. Evaluate conductor temperature at terminations per 110.14(C). -- vdrop= (7.98 *0 *0.001240hms) / 333.9264 0 Ampacity of wire derated for conditions of termination must be >= Module: Total voltage drop in DC conductors= 0.59 continuous current*1.25. All string terminations are rated at 90' C. Inverter 4: Inverter: 17.98 I 10 I AWG_10 at 240V. Vdrop= (7.98 *20 *0.0012 Ohms) / 240 V 0.0798 Total: 21 Modules Total Inv Pwr: 4800 4493.66 PTC Combined: 0 I 0 I I at 240V 2. OCP Sizing per Art 690.8(B)(1) Photovoltaic Module Electrical Specifications: Total STC: 5145 Vdrop= (0 *0 Ohms) / 240 V 0 a. Round up to next size per Art 240.4(B) Voc: 37.3 V deg F deg C 3. Conductor Sizing per Art 690.8(A) Vmp: 30.7 V Record Low Temp: 17 -8 Total voltage drop in AC conductors= 0.08 Ise: 8.47 A Max Average Hi Temp: 84 29 Total voltage drop in AC and DC conductors= 0.67 a. Conductor must have 30 deg. C ampacity >= 125% of continuous Imp: 7.98 A Record Hi Temp: 86 30 current. Tvoc: -0.11532 V/deg C Tisc: 4.185 mA/deg C b. Conductor must have (after corrections for conditions of use) >= String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc data Branch Circuit Type A 1 way wire length: 0 continuous current per Table 310.15(6)(16). Voc Correction Factor: Power One PVI 4.2 S 1 strings per branch 1 1 strings per branch 2 Inverter Min Vdc Input: 120 12 TRINA SOLAR#TSM;245PC05 12 modules per series string 9 modules per series string c. Evaluate conductor temperature at terminations per Art 110.14(C). Voc= 447.6 Min Vmp at Max Temp: 333.93 Voc= 447.6 V Voc= 335.7 V Ampacity of wire derated for conditions of termination must be >= Vmp= 368.4 Max Voc at Min Temp: 493.27 Vmp= 368.4 V Vmp= 276.3 V continuous current*1.25. All branch terminations are rated at 75' C Isc= 8.47 Inverter Max Vdc Input: 600 Isc= 8.47 A Isc= 8.47 A min. Imp= 7.98 Max String Size: 14 Imp= 7.98 A Imp 7.98 A (cont=l 10.59 Art 690.8(A)(1) 1-way wire length: 100 (cont=l 10.59 A (cont= 10.59 i A Art 690.8(A)(1) 4. OCP Sizing. 1.a Conductor: AWG_10 IPV Wire 2.a Conductor 1: AWG_10 PV Wire a. Round up to next size per Art 240.4(B) Conductor 2: AWG_10 PV Wire Icont*1.25=(Amps) 13.23 Conductor 1 Conductor 2 5. Conductor Sizing per Art 690.8(A) 30 deg C ampacity= 40 (cont*1.25=(Amps) 13.23 13.23 a. Conductor must have 30 deg. C ampacity >= 125% of continuous 1.b lcont=(Amps) 10.59 30 deg C ampacity= 40 40 Start ampacity 40 2.b Icont=(Amps) 10.59 10.59 current. Temperature derate(%=F) 0.71 Start ampacity 40 40 • Conduit fill derate(% ) 1 Temperature derate(%=F) 0.76 0.76 b. Conductor must have (after corrections for conditions of use) >= Derated ampacity 28.4 Conduit fill derate(%=#) • 0.8 0.8 continuous current per Table 310.15(B)(16). 1.c Derated ampacity 24.32 24.32 I . Icont*1.25=(Amps) 13.23 2.c Term 1 Term 2 c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity 40 I Temp table 75degC 75degC Ampacity of wire derated for conditions of termination must be >_ Icont*1.25=(Amps) 13.23 13.23 • P Y 1.d Icont 1.25=(Amps) I 13.23 continuous current*1.25. All inverter output terminations are rated at OCP Size= 15 Ampacity 35 35 I 75' C. Inverter Type A Output 2.d OCP Size= I 15I 15I Power-One PVI-4.2-S 1 way wire length: 10 ft i 6. OCP SizingCombined Inverter Output ,/� U�' R7 NO (cont= 20 A All 690.8(A)(1) Service Voltage= \((/ a. Round up to next size per Art 240.4(B) 3.a Icont*1.25=(Amps) 25 Art 690.8(B)(1) Total Inverter Power= ^,kt"'� ength= �UOICiI!'�G Q�'�&rttllenf OCP Size= 25 Art 240.6(A) (cont=#of inverters*max inverter current �` •1(1) (cont=(Amps) jr� 0 q 7. Conductor Sizing per Art 690.8(A) 3.b Conductor:l AWG_10 THWN-2 at 90 deg C:Table 310.16 '! MAY Q 3 2013 a. Conductor must have 30 deg. C ampacity >= 125% of continuous (cont*1.25=(Amps) 25 4.a ICont*1.25=(Amps) 43:.g:1'13t6'9' U.it(1�(1) current. 30 deg C ampacity= 40 OCP size= 1nCc�o l ()i+tlF LIA.NrE 3.c Icont=(Amps) 204.b Conductor: THWN-2 at 90 dea D Start ampacity 40 Icont*1.25=(Amps) Revirwed By �5.-.or.% ' Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT (C) MAXIMUM AC A (AC) (P01) (DC) (INV) Per Code: OPERATING CURRENT Per Code: WARNING Per Code: CA Fire Guidelines MAXIMUM AC _ v CEC 690.54 ELECTRIC SHOCK HAZARD CEC 690.35(F) DC CONDUCTORS OPERATING VOLTAGE THE PHOTOVOLTAIC SYST MF ARES TO BE USED WHEN Label Location: UNGROUNDED AND INVERTER IS PHOTOVOLTAIC DC (DC) (INV) MAY BE ENERGIZED UNGROUNDED DISCONNECT Per Code: CEC 690.14.C.2 Label Location: PV SYSTEM (AC) (P01) DISCONNECT FOR UTILITY OPERATION Label Location: MAXIMUM POWER- A (DC) (INV) POINT CURRENT(Imp) Per Code: MAXIMUM POWER-_v CEC 690.53 POINT VOLTAGE(Vmp) MAXIMUM SYSTEM Label Location: VOLTAGE(Voc) WARNING (AC) (POI) SHORT-CIRCUIT_A Per Code: CURRENT(Ise) ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS CEC 690.17 TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label Location: WARNING (DC) (CB) Per Code: ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS CEC 690.17 Label Location: TERMINALS ON BOTH LINE AND PHOTOVOLTAIC POINT OF (P01) LOAD SIDES MAY BE ENERGIZED INTERCONNECTION Per Code: IN THE OPEN POSITION WARNING: ELECTRIC SHOCK CEC 690.54; CEC 690.17 DC VOLTAGE IS HAZARD. DO NOT TOUCH ALWAYS PRESENT WHEN TERMINALS,TERMINALS ON SOLAR MODULES ARE BOTH THE LINE AND LOAD SIDE ' EXPOSED TO SUNLIGHT MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE ,r---';'7.74-11 CUPERTINO MAXIMUM AC ^1., I Building DaDartmeni Label Location: A r .o WARNING DC INV OPERATING CURRENT ( ) (INV) MAXIMUM AC ! ELECTRIC SHOCK HAZARD Per Code: OPERATING VOLTAGE V I1 ,fl MAYMf 2013 IF A GROUND FAULT IS INDICATED CEC 690.5(0) NORMALLY GROUNDED ,R,EV'EViJEO FOR CODE COMPLIANCE CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Label Location: 1 avlev.ed By j;e7.st /7/47 CAUTION (D) (POI) Per Code: PHOTOVOLTAIC SYSTEM Label Location: CIRCUIT IS BACKFED CEC 690.64.B.4 PHOTOVOLTAIC AC (AC) (P01) (AC): AC Disconnect Per Code: (C): Conduit DISCONNECT (CB): Combiner Box CEC 690.14.C.2 (D): Distribution Panel Label Location: (DC): DC Disconnect CAUTION (P01) (IC): Interior Run Conduit DUAL POWER SOURCE Per Code: (INV): Inverter With Integrated DC Disconnect SECOND SOURCE IS CEC 690.64.B.4 PHOTOVOLTAIC SYSTEM (LC): Load Center (M): Utility Meter (POI): Point of Interconnection 'CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR =„�j 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED �- San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, SC - CA Label Seti ' T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE /9 01a '� (888)-SOL-CITY(765-2489)www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. o mono multi solutions Trinamount II FOR PITCHED ROOF TSM-PC05/ PA05.18 mono multi solutions ELECTRICAL DATA STC TSM-225 TSM-230 TSM-235 TSM-240 TSM-245 I DIMENSIONS OF PV MODULE TSM-PCO5/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 Peak Power Watts-Pam/)Wp) 225 230 235 240 245 • 936 10 YEAR A R Power Output Tolerance-PMnx(%) 0/+3 0/+3 0/+3 0/+3 0/+3 r na m o u n t JJ " �� Maximum Power Votage Var(V) 29.4 29.8 30.1 30.4 30.7 PRODUCT WARRANTY FOR MODULE Max mum Power Current-lore(A) 7.66 7.72 7.81 7.89 7.98 by Trinasolar AND MOUNTING SYSTEM Open Circuit Voltage-Voc(V) 36.9 37.037.1 37.2 37.3 FOR PITCHED ROOF I, Short Circuit Cu ent-Isc(A) 8.20 8.26 8.31 8.37 8.47 Module Efficiency gm(%) 13.7 14.1 14.4 14.7 15.0 I 5X I _ FASTER TO INSTALL AL _IA _ Values at Standard Test Conditions STC(Air Mass AM 1.5.Irradiance I000W/m'.Cell Temperature 25'C). ULTRA L 0 W ELECTRICAL DATA @ NOCT TSM-225 TSM-230 TSM-235 TSM-240 TSM-245 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 RESISTANCE - Maximum Powe(W) Maximum Power Voltage(V) 164 26.9 168 172 175 178 27.1 27.4 27.7 27.8 GROUND BOND CONNECTION Maximum Power Current(A) 6.12 6.20 6.27 6.32 6.41 l OX BETTER THAN UL MINIMUM CRITERIA ° w E Open Circuit Voltage(V) 33.8 33.9 34.0 34.1 34.2 "�.. d°°"1NM0 1 _ Short Circuit Current(A) 6.62 6.68 6.70 6.75 6.83 s NOCT:Irradiance at 800W/m'.Ambient Temperature 20°C.Wind Speed 1M/s. I, \ Back View ti MECHANICAL DATA T , `x,, Solar cells Multicrystalline 156 x 156mm(6 inches) Cell orientation 60 cells(6 x 10) Module dimension 1650 x 992=40mm(64.95 x 39.05=1.57 inches) tis \y, .v•� Weight 20.3kg(44.8 Ib) 1 k \ �' x\ • \ \ � 4 \,..,, , q Glass High iransparancy solar glass 3.2mm(0.13 inches) - Frame Anodized aluminium alloy \\\,..\ \...\_ x--- J-Box IP 65 rated A-A Cables/Connector Photovoltaic Technology cable 4.0mm'(0.006 inches.), ,. 1100mm(43.3 inches),MC4/H4 I-V CURVES OF PV MODULE TSM-230PC05/PA05.18 990 1000W/m' I r- 89. 800 I 1 TEMPERATURE RATINGS . 740 - ----- -- /O1° Nominal Operating Cell 46°C(±2°C) <600(600w/m' -- ---- Temperature(NOCT) I 590 ---------------- ---- b Temperahxe Coefficient of PMA% -0.43%NC • S 49' 400W/m" _ u 3m Temperature Coefficient of Voc 0.32%/°C `t )1 f 20aw/mT C`�P E R I /'''� ro Ir _ _ _ ___ __ _ Temperature Coefficient of Isc 0 047%/°C'� �' V : I I - ` I adding De lartment SUITABLE FOR D:I _ _ \11 COMBINING PV MODULE EXPERTISE WITH A HIGHLY 000 10A0 209' 3040 4CP0MAXIMUM RATINGSINNOVATIVE MOUNTING SYSTEM SOLUTION. Voltage(V) A� g1?•• COMPOSITION SHINGLE Operational Temperature -40-+85°C MW' Trina Solar is introducing Trinamount-the fastest,easiest and least Max;mum systemvaltage 000voglEcl/bqo. • =1:;1 Fexpensive way to mount PV modules onto residential and commercial DC(UL) - / '-(� FOR CODE COMP NCE rooftops.With a series of drop-in and quarter-turn connections on a Max Series Fuse Rating 15A ;wie'rYeq By ��9,ti if. ® TRAPEZOIDAL METAL specialized module frame,this mounting solution installs up to 5 times CERTIFICATION faster than conventional mounting systems.Trinamount connects i, <' directly to the module frame,eliminating the need for long rails. (E ISO PV-tVCLE t4 cOus WARRANTY cir STANDING SEAM ROOF By drastically reducing the number of parts,cost of materials and �� l0 year workmanship warranty - installation time,Trinamount offers the optimal solution for residential u ) 25 year linear performance warranty 1 and commercial installations. � "uy ._ (Please refer to product warranty for details) r �ygB0MP4)'4 • Tr;nasolar Trinasolar A e CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. The power behind the panel ea�p<x The power behind the panel 02011 Trina Solo Limited Atl rights reserved.Specifications included;n this dotasheet are subject to charge without notice. SolarCity SleekMountTM - Tile SolarCity SleekMountTM - Tile The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules •aesthetics while minimizing roof disruption and Remove file and locate rafter •Interlock and grounding devices in system UL labor.The elimination of visible rail ends and listed to UL 2703 • Drill pilot holes of proper diameter for mounting clamps, combined with the addition fastener size per NDS section 1.1.3.2 of arraytrim and a lowerprofile all contribute to 3 Seal pilot holes with roofing sealant •Interlock and Ground Zep ETL listed to UL 1703 .� as"Grounding and Bonding System" l a more visually appealing system. SleekMount ` 4) Place tile hook utilizes Zep Compatible"' modules with •Ground Zep UL and ETL listed to UL 467 as strengthened frames that attach directly to Zep grounding device • Install lags pursuant to NDS section 11.1.3 with fender washer Solar standoffs,effectively reducing the number •Anodized components for corrosion resistance of standoffs required, when compared to • Notch underside of tile and reinstall tile 1 conventional rail-based systems. •Applicable for vent spanning functions • Attach Spanner Clamps and tighten firmly �„«. in place • Insert Cam Foot into Spanner Bar and rotate Cam Nut 100 degrees Components • Place modules `` • Cam Foot A ��t • • Spanner Bar I► • 3/8"Machine Screw and Nut • Spanner Bar Clamp �� • Tile Hook • Lag Screw(2) ir 41* 1 I 4II �. CUPER IN Q E ,l t ... ���`I Building Cupartmc:n ,arii Y V MAY 2013 REVIEWE_C FOR CODE COMPLIANCF Reviewed By jai,/ ,frig �'i° SolarCity® January �!W al) ® SolarCity.2013 a LISTED January2013 DMPP aoIFSr-oae= AURORA `lRenewable Energy Solutions TECHNICAL DATA VALUES PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-4.2-OUTD-US Nominal Output Power W 3000 3600 4200 - - -- -`- Maximum Output Power W 3000 3300" 3300" 3600 4000*" 4000"" 4200 4600** 4600** Q Rated Grid AC Voltage V 208 240 277 208 240 277 208 240 277 Z Input Side(DC) _ Number ofIndependent MPPT Channels 2 2 2 PVI-3.0-TI t( Maximum Usable Power for Each Channel W 2000 3000 3000 OC a Absolute Maximum Voltage(Vmax) V 600 600 600 Q a Start-Up Voltage(Vstart) V 200(ad).120-350) 200(adj.120-350) 200(adj.120-350) PVI-3.6-TL Full Power MPPT Voltage Range V 160-530 120-530 140-530 QOperating MPPT Voltage Range V 0.7xVstart-580 0.7xVstart-580 0.7xVstart-580 ` ` 42^ Maximum Current(Idcmax)for both MPPT in Parallel A 20 32 32 P11 4.1��� Maximum Usable Current per Channel A 10 16 16 "TT Maximum Short Circuit Current Limit per Channel A 12.5 20 20 ' ,,,rod Number of Wire Landing Terminals Per Channel 2 Pairs(1 on-S version) 2 Pairs(1 on-S version) 2 Pairs(1 on-S version) GENERAL SPECIFICATIONS Array Wiring Termination Terminal block,Pressure Clamp,AWG10-AWG4 DO^ Output Side(AC) Q U T /O R M O n IJ F I S Grid Connection Type 10/2W Split- 10/2W 10/2W Split- 10/2W 10/2W Split- 10/2W • 0/3W 0/3W 0/3W Adjustable Voltage Range(Vmin-Vmax) V 183-228 211-264 244-304 183-228 211-264 244-304 183-228 211-264 244-304 Grid Frequency Hz 60 60 60 Adjustable Grid Frequency Range Hz 57-60.5 57-60.5 57-60.5 1.4,, Maximum Current(lacmax) ABMS 14.5 14.5 12 17.2 16 16 20 20 20 995 The most common residential inverter is the ideal size for an average- Power aFrmor ><0.2 ><0 2 >0.2 Total Harmonic Distortion At Rated Power 9'0 <2 <2 <2 sized family home. This family of single-phase string inverter Grid Wiring Termination Type Terminal block,Pressure Clamp,AWG10-AWG4 complements the typical number of rooftop solar panels,allowing Protection Devices Input home-owners to get the most efficient energy harvesting for the ` Reverse Polarity Protection Yes Yes Yes size of the property.This rugged outdoor inverter has been designedr�'► Over-Voltage Protection Type Varistor,2 for each channel Varistor,2 for each channel Varistor,2 for each channel 'S PV Array Ground Fault Detection Pre start-up Riso and dynamic GFDI(Requires Floating Arrays) as a completely sealed unit to withstand the harshest environmentalIIIIMIR Output conditions. Anti-Islanding Protection Meets UL 1741/IEE1547 Meets UL 1741/IEE1547 Meets UL 1741/IEE1547 requirements requirements requirements Over-Voltage Protection Type Varistor,2(L,-Li/Li-G) Varistor,2(L,-Li/Li-G) Varistor,2(L,-L,/L,-G) One of the key benefits of the Uno family of single-phase inverters Maximum AC OCPD Rating A 20 20 15 25 20' 20 25 25 25 is the dual input section to process two strings with independent 111111111MMINKEIZEINIIIIIMIK Efficiency ) Maximum Efficiency % 96.9 97 97 MPPT especially useful for rooftop installations with two different CECEfficiency % 96 96 96 orientations(ie East and West).The high speed MPPT offers real-time • Operating Performance powerandim improvedharvesting. Stand-by Consumption Wins <8 <8 <8 tracking p energy * Night time consumption WA. 0 0.6 0 0.6 0 0.6 Communication The transformerless operation gives the highest efficiency of up to ) User-Interface 16charactersx2linesLCDdisplay Remote Monitoring)1xRS485 incl.) AURORA-UNIVERSAL(opt.) 97.0%. The wide input voltage range makes the inverter suitable to Wired Local Monitoring(1xRS485 incl.) PVI-USB-85485_232(opt.),PVI-DESKTOP(opt.) low power installations with reduced string size. Wireless Local Monitoring PVI-DESKTOP(opt.)with PVI-RADIOMODULE(opt.) ) Environmental Ambient Air Operating Temperature Range °F(°C) -13 to+140(-25 to+60)with -13 to+140(-25 to+60)with -13 to+140(-25 to+60)with derating above 131(55) derating above 131(55) derating above 113(45) Ambient Air Storage Temperature Range °F(°C) -40 to 176(-40 10+80) -40 to 176(-40 to+80) -40 to 176(-40 to+80) Relative Humidity %RH 0-100 condensing 0-100 condensing 0-100 condensing Acoustic Noise Emission Level db(A)@1m <50 <50 <50 Maximum Operating Altitude without Derating ft(m) 6560(2000) 6560(2000) 6560(2000) Mechanical Specifications Enclosure rating NEMA 4X NEMA 4X NEMA 4X • Each inverter is set on specific grid codes which can be selected in the field Cooling Natural Convection Natural Convection Natural Convection Dimensions(H x W x D) in(mm) 33.8 x 12.8 x 8.7(859 x 325 x 222)-S Version • Single phase output Weight Ib/(kg) <47.3(21.3)-S version <47.3(21.3)-S version 047.3(213)-S version • Dual input sections with independent MPPT,allows optimal energy harvesting from two sub-arrays oriented in Mounting System Wall bracket Wall bracket Wall bracket ti Trade size KOs:(tea x 1/2")and Trade size KOs:(tea x 1/2")and Trade size KOs:(tea x 1/2")and different directions Conduit Connections*** (2eax1-1/4,3 places side,front, (2eax1-1/4;3places side,fjont;. -(2eax.4-1/4"3 places side,front • Wide input range rear) rear) '!! rear) L UPERTINO Hi hs eedandMPPTaI orithmforrealtimeandim rovedwitchRatinglPerContact) AN zs/600 zs/600 4t., zs/boo y� l)�i • 9 P precise9 powertracking P energy harvesting Safety "�i l L1 nq De 8. t • Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across Isolation Level Transformerless(Floating Array) Transformerless(Floating, ay)..,,Transfprmerless(Floating Array) rt01@f1 Safety and EMC Standard UL 1741,CSA-C22.2 N.107.1-01 UL1741,CSA-C222N ii 1 IJL174,1,CSA-C22.2N 107.1-01 the entire input voltage and output power range Safety Approval ,CSA", ,CSA ,;,.#311114_ ccs, i q • Outdoor enclosure for unrestricted use under any environmental conditions Warranty - L. ft l �1 • Integrated DC disconnect switch in compliance with international Standards(-5 Version) Standard Warranty years 10 10 10 Extended Warranty years 15&20 15&20 E-VIE.- ''- 15&20 `, • RS-485 communication interface(for connection to laptop or datalogger) Available Models "`�l�E COMF LiANCE • Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP Standard-Without DC Switch and Wiring Box PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-4.2-OUTD-US With DC Switch and Wiring Box PVI-3.0-OUTD-S-US PVI-3.6-OUTD-S-US `'''t'iis£A-4. O.UTg--US -77� "All data is subject to change without notice ""Capability enabled at nominal AC voltage and with sufficient IX power available ...When equipped with optional DC switch and Wiring Box AURORA UldO 3 CSA INTERNATIONAL Certificate of Compliance Certificate: 2096477 Master Contract: 173688 Project: 2439385 Date Issued: July 19,2011 Issued to: Power-One,Inc 740 Calle Plano Camarillo,CA 93012 USA Attention:Robert White The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C'and 'US'for Canada and US or with adjacent indicator 'US'for US only or without either indicator for Canada only. Rob-Hempstock Issued by: Rob Hempstock,AScT. C US PRODUCTS CLASS 531109 -POWER SUPPLIES-Distributed Generation Power Systems Equipment • CLASS 531189 -POWER SUPPLIES-Distributed Generation-Power Systems Equipment -Certified to U.S.Standards Utility Interactive Inverter,Models PVI-4.2-OUTD-US,PVI-3.6-OUTD-US,PVI-3.0-OUTD-US,PVI-4.2- OUTD-S-US,PVI-3.6-OUTD-S-US,PVI-3.0-OUTD-S-US,PVI-4.2-OUTD-US-W,PVI-3.6-OUTD-US-W and PVI-3.0-OUTD-US-W;provided with two DC input channels,permanently connected. For details related to ratings,reference should be made to the CSA Certification Record,Appendix 1 or the Descriptive Report. APPLICABLE REQUIREMENTS CSA-C22.2 No.107.1-01 - General Use Power Supplies �`� �.� Bilildirlg DeFartmment UL Std No. 1741-Second Edition - Inverters,Converters,Controllers and Interconnection System Equipment 'i for Use With Distributed Energy Resources(January 28,2010) a � l , � REVIEWED FOR CODE COMPLIANCE Reviewed By ���, / �, DQD 507 Rev.2009-09-01 Page:1 1