Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13060166
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 22530 RICARDO RD CONTRACTOR:SOLARCITY PERMIT NO:13060166 OWNER'S NAME: STEPHEN POON 3055 CLEARVIEW WAY DATE ISSUED:06/20/2013 OWNER'S PHONE: 4082504470 SAN MATEO,CA 94402 PHONE NO:(650)638-1028 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL❑ COMMERCIAL0 License Class_ t 9 Lica# N st C^) INSTALL 25 ROOF MOUNTED PV PANELS(6.125 KW) Contractor �11(QX Date W%'/., 1 I I hereby affirm that I am lice .:1 under the provisions of Chapter 9 (commencing with Section 700: of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$25000 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor.Code,for the performance of the work for which this . APN Number:35601008.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DA % PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 1: ! i • S ' n If , LLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, /� /(2-6//7 / ^� costs,and expenses which may accrue against said City in consequence of the I b �'-' Date (!1 ZO f 3 granting of this permit. Additionally,the applicant understands and will comply with all non-point source regulation -r the Cupertino Municipal Code,Section • 9.18. . I V m 1 r�,m RE-ROOFS: I 0 Date C 6 / I5 All roofs shall be inspected prior to any roofing material being installed.If a roof is Signature ��� _ �� installed without first obtaining an inspection,I agree to remove all new materials for inspection. 0 OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages-as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE . construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Se 4'ns 25505,25' :nd 25534. �A / Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized age / ,i ( II.' • Dater d 2e ((2 • permit is issued. I-certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If,after making this certificate of exemption,I become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which,may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,theapplicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date \� / ALTERNATIVE ENERGY PERMIT APPLICATION V. 1.1).:V COMMUNITY DEVELOPMENT DEPARTMENT-BUILDING DIVISION �` AE 1/4.,,1.1 9,, 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 �� CUPERTINO (408)777-3228•FAX(408)777-3333•building ancupertino.orq PROJECT ADDRESS 7 2s3o )Ce rciT _/Ict APN# 3 C & - O 1 -_ 00E OWNER NAMEP©Z n / V PHONE(�0s)'2sv V Li 4-70 E-MAIL STREET ADDRESS 2 2 5.3 0 kiCGxcto kiriCITY,STATE,ZIP C n L i to 0 /J. 0 1, t FAX CONTACT NAME Ctn n 00 Rx) PHONtpros_q_ 6„,3 I E-MAIL ss FraP(9_1 cola-i-C, r 42 STREET ADDRESS ✓"'( 5C,(e,_ 0+,4 6,ivci CITY,STATE,ZIP c„.4.1 c -I 9 O y FAX ❑OWNER ❑ OWNER-BUILDER 0 OWNER AGENT CONTRACTOR XCONTRACTOR AGENT 0 ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑TENANT CONTRACTOR NAME (J ( n Crp LICENSE NUMBER C4 r 49 ,c(� LICENSE TYPE BUS.LIC# g r' (0 ti, COMPANY NAME l E-MAIL&v k,,t,l U Y' p & ! A - C FAX STREET ADDRESS e-yi i -54er C (_ , �f/� CITY,STATE,ZIP 1Aei /�`+i 1(11‘,i0 9 PHONE( �ps- N ARCHITECT/ENGINEER NAME ��� L LICENSE NUMBER S BUS.LIC# J\ COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OFFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: CI Commercial URBAN INTERFACE AREA ❑ Yes o FLOOD ZONE 0 YesNo I SOLAR PANELS 0 ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING 0 OTHER: yy�� �1,._ FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: KILOWATTS(COMMERCIAL ONLY): G• 1 S TOTAL VALUATIOf �[ " 0 u V n (� 1y� y�,, CC 11 l DESCRIPTION OF WORK �r)Sizt.I,i Q. `-F I Us I 1 l I e Y) t 1 to 0� - iv c 5o\ct r poJJL\S - RECEIVED BY: By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provided is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating t. 'ding construction. uthorize■representatives of Cupertino to enter the above-identified property for inspection purposes. Irr Signature of Applicant/Agent: 0 F •iii •• , (Ih Date: Gj/2z)`I SUPPLEMENTAL INFORMATION REQUIRED OFFICE USE ONLY N 0 OVER-THE-COUNTER I 0 EXPRESS W VW R7 0 STANDARD LI ''t ❑ LARGE a. 0 MAJOR PVApp_2011.doc revised 03/16/11 CITY OF CUPERTINO FEE ESTIMATOR-BUILDING DIVISION r ,/ ; ADDRESS: 22350 RICARDO RD DATE: 06/20/2013 REVIEWED BY: MELISSA .y4•I's:,-... APN: 356 01 008 I BP#• *VALUATION: I$25,000 I *PERMIT TYPE: Building Permit I PLAN CHECK TYPE: Alteration/ Repair PRIMARY PENTAMATION SOLAR-RES USE: SFD or Duplex PERMIT TYPE: i WORK INSTALL 25 ROOF MOUNTED PV PANELS (6.125 kW) SCOPE 1 r - z iv P `. ;r mech.Plan Check Plumb Plan Check Elec.Plan Check 1tec;Ir.Permit Fee:. Plumb.Permit Pee: l lec. Permit Tee: • IOther Mech.Insp. _ Other Plumb Insp. Other Elec.Insp. Mech.Insp.Fee: Plumb. Insp.Fee: -1 Elec.Insp.Fee: NOTE:This estimate does not include fees due to other Departments(Le.Planning,Public Works,Fire,Sanitary Sewer District,School District,eta). These fees are based on the preliminary information available and are only an estimate Contact the Dept for addn'1 info. FEE ITEMS(Fee Resolution 11-053 E_ . 7/1/12) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 1 # Alternative Energy System Suppl.PC Fee: Q Reg. 0 OT 0.0 hrs $0.00 $219.00 IPHOTOVRES Photovoltaic System 1 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp.Fee:0 Reg. 0 OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Construction Tax: Administrative Fee: Work Without Permit?. 0 Yes Q No $0.00 Advanced Planning Fee: $0.00 Select a Non-Residential 0 Building or Structure Trawl Documentation Fees: A Strong Motion Fee: IBSEISMICR $2.50 Select an Administrative Item.. Bldg Stds Commission Fee IBCBSC $1.00 r g Q,1 '' $3.50 $219.00 r $222.50 Revised: 04/29/2013 Building.Department City Of Cupertino 10300 Torre Avenue <4 4' Cupertino,CA 95014-3255 Telephone: 408-777-3228 CUPERTINO Fax: 408-777-3333 CONTRACTOR/SUBCONTRACTOR LIST I JOB ADDRESS: '2 Z 5-3b C‘,C& -L PERMIT# /3O 0 b OWNER'S NAME: Q PHONE# (Q GENERAL CONTRACTOR: S t\ax Ci BUSINESS LICENSE# �1 ADDRESS: ( -F cekr C j\vA CITY/ZIPCODE: 'b C GI4\0y *Our municipal code requires all busines es working in the city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRA -t RS HAVE OBTAINED A CITY" OF CUPERTINO BUSINESS LICENSE. V G/2-6/(3 I am not using any subcontractors: :� Q Signature Date Please check applicable subcontractors and complete the following information: i/ SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets &Millwork Cement Finishing Electrical Excavation Fencing Flooring/Carpeting Linoleum/Wood Glass/Glazing Heating Insulation Landscaping Lathing Masonry Painting/Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock - Tile Owner/Contractor Signature R> Date ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING FLASHING WILL BE PAINTED TO MATCH EXTERIOR AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN BLDG BUILDING POSITION, A SIGN WILL BE PROVIDED WARNING PLOT PLANS CONC CONCRETE OF THE HAZARDS PER ART. 690.17. INSTALLING 25-ROOF TOP FLUSH-MOUNTED PANELS (6.125KW) RECEIVED CHECKED BY, DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED APN:356-01-008 II cOPYJUN 2 0 2013 - 7.0—�� BY PHASE AND SYSTEM PER ART. 210.5. �I , DATE (E) EXISTING , _ EMT ELECTRICAL METALLIC TUBING 3. A NATIONALLY-RECOGNIZED TESTINGik F __ GALV GALVANIZED LABORATORY SHALL LIST ALL EQUIPMENT IN i+ - - 3,4.....4.1 PLANNING DEPT. GEC GROUNDING ELECTRODE CONDUCTOR COMPLIANCE WITH ART. 110.3. GND GROUND 4. CIRCUITS OVER 250V TO GROUND SHALL HDG HOT DIPPED GALVANIZED COMPLY WITH ART. 250.97, 250.92(B) ' DATE ICURRE NT 5. DC CONDUCTORS EITHER DO NOT ENTER Imp CURRENT AT MAX POWER BUILDING OR ARE RUN IN METALLIC RACEWAYS COMMUNITY DEVELOPMENT DEPARTMENT RI,DG. DEPT Isc SHORT CIRCUIT CURRENT OR ENCLOSURES TO THE FIRST ACCESSIBLE DC BUILDING DIVISION - CUPERTINO kVA KILOVOLT AMPERE DISCONNECTING 6. ALL WIRES SHALLEBE PROVIDED ANS PER TWIT kW90.31(E). WKILOWATT H STRAIN APPROVED LBW LOAD BEARING WALL RELIEF AT ALL ENTRY INTO BOXES AS This set of plans and specifications MUST be kept at the MIN MINIMUM REQUIRED BY UL LISTING. job site during construction. It is unlawful to make any (N) NEW 7. MODULE FRAMES SHALL BE GROUNDED AT THE changes or alterations on same, or to deviate NTS NOT TO SCALE UL-LISTED LOCATION PROVIDED BY THE OC ON CENTER MANUFACTURER USING UL LISTED GROUNDING therefrom, without approval from the Building Official. PL PROPERTY LINE HARDWARE. The Stamping of this plan and •:. cations SHALL NOT ,`' CUPERTINO POI POINT OF INTERCONNECTION 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE be held to permi • oval of the violation I` • ` -y Building Department PV PHOTOVOLTAIC BONDED WITH EQUIPMENT GROUND CONDUCTORS of any , .,, - •.nance or State Law. JUN n 2013 SCH SCHEDULE AND GROUNDED AT THE MAIN ELECTRIC PANEL. 1 SS STAINLESS STEEL 9. THE DC GROUNDING ELECTRODE CONDUCTOR _i%i� STC STANDARD TESTING CONDITIONS SHALL BE SIZED ACCORDING TO ART. DATE #Za TYP TYPICAL 250.166(B) & 690.47. P,P\IEV\'ECD FOR CODE COMPLIANCE UPS UNINTERRUPTIBLE POWER SUPPLY PERMIT NO. / 3060 /64 r. V VOLT Reviev,' � N AT Vmp VOLTAGE AT MAX POWER W c WATT VOLTAGE AT OPEN CIRCUIT VICINITY MAP INDEX 3R NEMA 3R, RAINTIGHT e " `' ' ,,1a 4-1-; ` PV1 COVER SHEET I TIN iferl; 7-1".. e Dr i �. ',' 'w PV2 SITE PLAN ,. rQ` Ir w„-`. 0' PV3 STRUCTURAL VIEWS _ , C 4 # • 4,,. n PV4 STRUCTURAL VIEWS * `-r �#W. $ t' PV5 UPLIFT CALCULATIONS LICENSE GENERAL NOTES ; . s to ! .� ,* I PV6 THREE LINE DIAGRAM 6 '� PV7 ELECTRICAL CALCULATIONS CA # 888104 1. THIS SYSTEM IS GRID-INTERTIED VIA A O� R r . ,' 8 .. zs PV8 ELECTRICAL CALCULATIONS C-46, C-10 UL-LISTED POWER-CONDITIONING INVERTER. '" 3P III*', ` •k2 ` Ar , Cutsheets Attached 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. �� x �I '� 5 6 r , a /" 3. PHOTOVOLTAIC SOURCE AND INPUT CIRCUITS AND R ' .1'A Q1�Q' a t11 . �.� sQ r _ INVERTER INPUT CIRCUIT ARE UNGROUNDED. MODULE GROUNDING METHOD: SLEEKMOUNT 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED `• y"".� `1k.. 5. ALL WORK TO BE DONE TO 2010 CALIFORNIA � AHJ: Cupertino BUILDING CODE. " -� REV BY DATE COMMENTS 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE • , ~ po REV A NAME 6/14/2013 COMMENTS 2008 NATIONAL ELECTRIC CODE AS AMENDED BY *r> ��4 UTILITY: Pacific Gas and Electric Company (PG&E) THE 2010 CALIFORNIA ELECTRIC CODE. A* " Y ' `-.. * * * * * 'ei,i a Cr. U.S. Geolo•ical Surve USDA F.rm ServiceA•e * * * * CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-9501840 00 PRASE OWNER: DESCRIPTION: DESIGN: `064 CONTAINED SHALL NOT BE USED FOR THE POON, STEVE POON RESIDENCE Elliot Law -• y SolarC�t BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 22530 RICARDO RD 6.125 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: CUPERTINOCA 95014 ORGANIZATION, EXCEPT IN CONNECTION WITH , 3055 Cleorview Way THE SALE AND USE OF THE RESPECTIVE (25) TRINA SOLAR # TSM-245PC05/PA05.18 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN 7 PAGE NAME: SHFET REV. DATE San Mateo, CA 94402 PERMISSION OF SOLARCITY INC. ���' 40825044/0 PV 1 6/14/2013 (888)—SOL—CITY SOL) TY(765 9)F:(650)w638-102 POWER-ONE # AURORA PVI-3.0-OUTD-S-US-Z COVER SHEET )638(ass 638-1029 om PITCH: 20 ARRAY PITCH:20 MP1 AZIMUTH:204 ARRAY AZIMUTH:204 MATERIAL: Flat Cement Tile STORY: 1 Story PITCH: 20 ARRAY PITCH:20 fr4AZIMUTH:204 ARRAY AZIMUTH:204 'A. MATERIAL: Flat Cement Tile STORY: 1 Story PITCH: 20 ARRAY PITCH:20 -410/ MP3 AZIMUTH:174 ARRAY AZIMUTH: 174 0441 MATERIAL: Flat Cement Tile STORY: 1 Story PITCH: 20 ARRAY PITCH:20 Air MP4 AZIMUTH:204 ARRAY AZIMUTH:204 MATERIAL: Flat Cement Tile STORY: 1 Story \ o Us-Lodged c,24PITCH: 20 ARRAY PITCH:20 Front Of House MP5 AZIMUTH:204 ARRAY AZIMUTH:204 `� MATERIAL: Flat Cement Tile STORY: 1 Story \ 22530 Ricardo Rd ‘ ■ r \\.\\\::\O C MP1 eSetback LEGEND c °a ® ® , o o 0 (E) UTILITY METER & WARNIN G LABEL O O ° ° \ o° c o" ® INVERTER W/ INTEGRATED DC DISCO CO & WARNING LABELS \ 0 If', 0 0 \ 9 �� DC DISCONNECT & WARNING LABELS 0 o4 >< AC o ,` 1-'--1 AC DISCONNECT & WARNING LABELS dill o / 3a o JUNCTION BOX /" 0% 0 • I DC COMBIIR 1g8] A�'IATi ' TOTAL ARRAY AREASF:450 6 ( ) o , ° .zDISTF3COTION PA141 ( & WARNING TOTAL ROOF AREA (SF):2019 0 ••.0`'' TOTAL ARRAY AREA IS 1,415 o MP4 0 PERCENT OF TOTAL ROOF AREA 0 �4� EW r I f3t644 - WQf�NING.L`A�f`Lt ° Reviewed By ��, t��� ' O DEDICATED PV SYSTEM METER /*ACONDUIT CONDUIT RUN ON EXTERIOR �' ® RUN ON INTERIOR 1 9 — GATE/FENCE 4111, k„Air -',i4' Ay' tetr—. ''' ' < , INTERIOR EQUIPMENT 1 ,, A 1, SITE PLAN N + „ ft ` Scale: 3/32” = 1' tr .a T . -Ale N 01' 10' 21' v' N �r ;ri V1*iII - S - II — 111 CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J B-9501 840 00 —PREMISE OWNER: DESCRIPTION: DESIGN: -0144 CONTAINED SHALL NOT BE USED FOR THE POON, STEVE POON RESIDENCE Elliot Law ,;;NEREST LL AIT BE EDI EXCECLOS TD SOIN WHOITYLE IRCI, MOUNTING SYSTEM: 22530 RICARDO RD 6.125 KW PV Soiar( ity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook Array PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: CA 95014 ORGANIZATION, EXCEPT IN CONNECTION WITHCUPERTINO, 3055 Clearvew way THE SALE AND USE OF THE RESPECTIVE (25) TRINA SOLAR # TSM-245PC05/PA05.18 PAGE NAME SHEET: REV DATE San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF sotaRarr INC. POWER-ONE # AURORA PVI-3.0-OUTD-S-US-Z 4082504470 SITE PLAN PV 2 6/14/2013 (888)-SOL-CITY(765-2489)www.saarcity.cam ® MODULE IS 4" OFF MODULE IS 4" OFF ROOF DECK ROOF DECK Alk9 0 _ii00... 00, /// 111.111.1P- -2" —11" klI i; 11'-9" 111 (E) LBW 1'—.1 (E) LBW SIDE VIEW OF MP2 RAFTER: (E) 2x6 © 16" O.C. B CEILING JOIST: (E) 2x10 ® 16" O.C. SIDE VIEW OF MP1 RAFTER: (E) 2x6 ® 16" O.C. NTS RIDGE: (E) 2x8 RIDGE BOARD A CEILING JOIST: (E) 2x10 CO 16" O.C. MAX SPAN: 9'-11" NTS RIDGE: (E) 2x8 RIDGE BOARD MAX STANDOFF DISTANCE: 64" O.C. MAX SPAN: 11'-9" MAX STANDOFF DISTANCE: 64" O.C. CUPERTINO 4" MODULE IS 4"OFF 12Ii L 11din D a MODULE IS OFF ROOF DECK ® ROOF DECK ;� 4 g Department a ® � ,/ � � I 1, SUN 2 0 2013 i`�� ► REVIEWED FOR CODE COMPLIANCE 11111111.1=k " 111 —2 , :—1 Reviewed By ,_... .9"/ h —2" kl; 10'-7" (E) LBW M (E) LBW SIDE VIEW OF MP4 RAFTER: (E) 2x6 ® 16" O.C. Go SIDE VIEW OF MP3 RAFTER: (E) 2x6 c 16" O.C. D NTS CEILING JOIST: (E) 2x10 ® 16" O.C. RIDGE: (E) 2x8 RIDGE BOARD NTS CEILING JOIST: (E) 2x10 ® 16" O.C. MAX SPAN: 8'-1" RIDGE: (E) 2x8 RIDGE BOARD MAX STANDOFF DISTANCE: 64" O.C. MAX SPAN: 10'-7" MAX STANDOFF DISTANCE: 64" O.C. CONFIDENTIAL—THE INFORMATION HEREIN JOB NUMBER: J B-9501840 00 PREMISE OWNER: DESCRIPTION: DESIGN: `1•1144' CONTAINED SHALL NOT BE USED FOR THE �• BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: POON, STEVE POON RESIDENCE Elliot Law ■ ` NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 22530 RICARDO RD 6.125 KW PV Array .I,• • SolarCity PART TO OTHERS OUTSIDE THE RECIPIENT'S Mo0uLEs CUPERTINO, CA 95014 ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (25) TRINA SOLAR # TSM-245PC05/PA05.18 3055 De Iew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV. DATE San Mateo,CA 94402 PERMISSION OF SOLARCITY INC. '"`�'� 4082504470 PV 3 6/14/2013 BB8 Tg6So)635-'0628 F:(�O)63"-'0629 _ POWER—ONE # AURORA PVI-3.0—OUTD—S—US—Z STRUCTURAL VIEWS ( )-sa-an(765-2489)www.edaroitycam INSTALLATION ORDER ZEP SPANNER BAR LOCATE RAFTER, MARK RAFTER (6) LOCATION, AND REMOVE TILE. (1) PLACE STANDOFF BASE & DRILL A . AN •vimmiM PILOT HOLES AT THE RAFTER �� LOCATION. • " DIA BOLT & NUT �) —(1) (2) Lifr-dumw•-----4".....""`"No•— (Z) (3) 2) CLEAN PAPER AROUND PILOT ZEP SPANNER �.� _� _ HOLE. BAR CLAMP �7T � ,\ 3 ADJUST STANDOFF TO BATTEN 1.l L � ' ` HEIGHT. STANDOFF (E) TILE SEAL PILOT HOLES AND BOTTOM U (4) OF STANDOFF WITH POLYURETHANE (E) ROOF DECKING (5) (4) SEALANT. 5/16" DIA LAG BOLT 5) LAG STANDOFF INTO RAFTER. (2-1/2" EMBED, MIN) LOWEST MODULE SUBSEQUENT MODULES (E) RAFTER 6) NOTCH TILE WEATHERING TO FIT STA N DOFF AROUND STANDOFF. S i Scale: 1 1/2" = 1' ( REINSTALL TILE. r,I CUPERTINO Euilding Department .a.i5j;-.,F Yom. JUN 2 0 2013 REVIEWED FOR CODE COMPLIANCE Reviewed By -5;-.9,/ /749/ CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-9501840 00 PREMISE OWNER: DESCRIPTION: DESIGN: `0114 kettor CONTAINED SHALL NOT BE USED FOR THE POON, STEVE POON RESIDENCE Elliot Law �:, BENEFIT OF ITANYONE EXCEPT SOLWHOLY INC., MOUNTING t: ' SoIa�itY NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 22530 RICARDO RD 6.125 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: CUPERTINO, CA 95014 ° ORGANIZATION, EXCEPT IN CONNECTION WITH —' THE SALE AND USE OF THE RESPECTIVE (25) TRINA SOLAR # TSM-245PC05/PA05.18 3055 aE0")°"Way SOLARCITY EQUIPMENT,WITHOUT THE WRITTEN PAGE NAME: MET: REV DAIS San Mateo,CA 94402 PERMISSION OF SOLARCITY INC. MVfRIER' 4082504470 PV 4 6/14/2013 •(650)638-1028 F:(650)638-1029 POWER—ONE # AURORA PVI-3.0—OUTD—S—US—Z STRUCTURAL VIEWS (888)—SOL—CITY(765-2489)www.solarouy.com UPLIFT CALCULATIONS 06.14.2013 Version#12.4 Wind Uplift Calculator Project Information Risk Category II PV System Type SolarCity SleekMount"' Flat Tile Roof Flat Tile Roof #of Layers(Comp Roof Only) NA Roof Slope 20° Rafter Spacing 16"0.C. PV Module Orientation Landscape Total Area of Array 440 sf PV Module Width 3.3 ft PV Module Length 5.4 ft Attachment Type 5+P FT Ground/Roof Snow Loads Ground Snow Load pq 0.0 psf ' ASCE Table 7-1 Roof Snow Over PV Modules ps-pv 0.0 psf Surrounding Roof Snow ps-roof 0.0 psf Wind Design Criteria Wind Design Code ASCE 7-05 Wind Design Method Partially/Fully Enclosed Method Basic Wind Speed V 85 mph Fig.6-1 Exposure Category B ' Section 6.5.6.3 Roof Style Gable Roof 'Fig.6-118(CD-14A18 Mean Roof Height h 16 ft Section 6.2 Least Horiz.Dim.of Building LHD 40 ft Effective Wind Area(1 Module) A 17.6 sf IBC 1509.7.1 Roof Wind Zone Width a 4 ft Wind Pressure Calculation Coefficients Wind Pressure Exposure Kz 0.70 Table 6-3 Topographic Factor Kzt 1.00 Section 6.5.7 Wind Directionality Factor Kd 0.85 Table 6-4 CUPERTINO Importance Factor I 1.0 Table 6-1 Building Departm:nt Velocity Pressure qh Equation= 0.00256(Kz)(Kzt)(Kd)(V^2)(I) Equation 6-15 11.0 psf Ext.Pressure Coefficient(Up) GCp(Up) -0.9 Fig.6-11BJC/O-14.y:B 313 Ext.Pressure Coefficient(Down) GCp(Down) 0.5 Fig.8-118/C1D-14A/8 Design Wind Pressure p p= qh(GCp) Equation 6-22 Wind Pressure Up p(up) -10.0 psf OR CODE COMPLIAf`CE Wind Pressure Down p(down) 10.0 psf h! -r rZCviwvad By -yt. Tile Allowable Attachment Spacing (In.) And Tributary Area (Ft^2) Max Allowed Foot X-Spacing Landscape 64" 44" Max Allowed X Cantilever Landscape 24" Max Standoff Tributary Area TribCL 20 sf PV Assembly Dead Load WPV 3 psf WLUP-0.6 DLPVcos(9) TCL -162 lbs Attachment Uplift Capacity Tallow 500 lbs TCL/Tallow DCRLand 32.5% CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-9501 840 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: ...owl, CONTAINED SHALL NOT BE USED FOR THE POON, STEVE POON RESIDENCE Elliot Law ; ,; NEST OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 'I' SolarCity NORORSHALL IT BE DISCLOSED IN WHOLLE ORRIN ZEP Mighty Hook 22530 RICARDO RD 6.125 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES: CUPERTINO, CA 95014 - ORGANIZATION, EXCEPT IN CONNECTION WITH ae THE SALE AND USE OF THE RESPECTIVE (25) TRINA SOLAR # TSM-245PC05/PA05.18 SHEET: REV DATE: 3055 San Mateo,Cle94402 CA orNeway W SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER, PAGE NAMET:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. POWER-ONE # AURORA PVI-3.0-OUTD-S-US-Z 4082504470 UPLIFT CALCULATIONS PV 5 6/14/2013 (888)—SQL—PTY(765-2489)www.s4arcity.cam GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD (E 200A MAIN SERVICE PANEL Inv 1: DC Ungrounded CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP {(� INV 1 —(1)POWER-ONE#AURORA PN-3.0-0U1D-S-US-Z LABEL: A —(25)TRINA SOLAR # TSM-245PC05/PA05.18 E Inv 2: DC Ungrounded 200/2P MAIN CIRCUIT BREAKER g Inverter, 3000W, 240V,96% PV Module; 245W, 222.9W PTC, 40MM, Black Frame C-46, C-10 anel Number:Square D INV 2—(1)POWER-ONE#AURORA PVI-3.0-OUTD-S-US-Z LABEL: B Meter Number:1006097188 Inverter, 3000W, 240V,96% Voc: 37,3 Vpmax: 30.7 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER MAIN SERVICE PANEL Inverter 1 PAR BRYANT 200A 2P © Load Center ® POWER-ONE m/ AURORA PVI-3.0-OUTD-S-US-Z 2 (E) LOADS 20A/2P ^ ♦ N 1 ECM GFP/GFCI (ion 40A/2P - -L I _ — T DC+DO NOT ADJUST MIN.ACTIVATION V LTAGE MJ EGC/ - •� DC+ A03 Oa 1 r DEC DC- DC- _i_— 1 String(s)Of 11 On MP 1& I I r I '--.� L B I I w I I GND I____EGC V EGC J I I I . I I I j--r�_r�--,ti♦_1 N i Inverter 2 IND _ I o z _ EGC/GEC_ I i' O5 POWER-ONE DC+ Z DO NOT ADJUST MIN.ACTIVATION 3LTAGE I / AURORA PVI-3.0-OUTD-S-US-Z DC- 1 String(s)Of 8 On MP 3 j 20A 2P • EGC — T----GEC --1, 1 i[ Q110-- /� iL1 I ' TO 120/240V 1 I O- I •-GFP/GFCI•— DC+ 1 N 3 SINGLE PHASE I L_ EGC/ •--"- DC+ I DC+DO NOT ADJUST MIN.ACTIVATION V LTAGE UTILIN SERVICE V GEC a DC- DC- 1 String(s)Of 6 On MP 2 1 -EGC __ EGC 1LI I (1)Conduit Kit 3/4"EMT V s t ref CUPERTINO ^1 Building Department f (1)SQUARE D#H0MT2020240 PV BACKFEED BREAKER A —(1)BRYANT#BR816L125RP "� �}�y r POI Breaker; 20A/1P-40A 2P-20A/IP,2 Spaces,Quad Tandem Load Center, 125A.120 240V,NEMA 3R AC T E JUN 2 Q 2 33 DC —(1)Ground Rot 5/8'x 8'Copper —.(2) Breaker, MER#2 Spaces ' REVIEWED FOR CODE COMPLIANCE Reviewed B ,_,. ,..4,-/ , (1)AWG 18, THWN-2,Black (1)AWG#10,THWN-2,Black (2)AWG#10,PV WIRE,Blade Voc =410.3 VDC Isc =8.47 ADC © —(1)AWG THWN-2 Red (2-1. (1)AWG#10,THWN-2,Red (� 666 O 1-r-(1)AWG#B,Slid Bare Capper EGC Vmp =337.7 VDC Imp=7.98 ADC • (1)AWG/8, THWN-2,White NEUTRAL Vmp =240 VAC Imp=29 MC (1)AWG#10,THWN-2,White NEUTRAL Vmp =240 VAC Imp=14.5 MC " (1)Conduit Kit; 3/4"DAT —(1)AWG 8, THWN-2,Green EGC/GEC —(1)Conduit Kit; 3/4"DAT —(1)AWG#8„1HWN-2,Green EGC/GEC —(1)Conduit Kit; 3/4"EMT (2)AWG#10,PV WIRE,Black Voc =298.4 VDC Isc =8.47 ADC CD (1)AN#10,THWN-2,Black O (1)AWG#8,Solid Bare Copper EGC Vmp =245.6 VDC Imp=7.98 ADC (1)AWG#10,THWN-2,Red III���JJJ III��—(1)AWG#10,111114-2,White NEUTRAL Vmp =240 VAC Imp=14.5 MC (2)AWG#10,PV WIRE,Black Voc =223.8 VDC Isc =8.47 ADC —(1)AWG#8,THWN-2, Green EGC/GEC —(1)Conduit Kit; 3/4'EMT O (1)AWG#8,Solid Bare Copper EGC Vmp =184.2 VDC Imp=7.98 ADC CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J B-9501840 00 PREMISE OWNER: DESCRIPTION: DESIGN: `064 CONTAINED SHALL NOT BE USED FOR 1HEAle BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: POON, STEVE POON RESIDENCE Elliot Law �� �� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 22530 RICARDO RD 6.125 KW PV Array Pi�SolarCity PART TO OTHERS OUTSIDE THE RECIPIENT'S Ma0utls CUPERTINO CA 95014 - ORGANIZATION, EXCEPT IN CONNECTION WITH , THE SALE AND USE OF THE RESPECTIVE (25) TRINA SOLAR # TSM-245PC05/PAO5.18 3055 Clearview Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN "" " " PAGE NAME SHEET. REV: DATE San Mateo,CA 94402 PERMISSION OF SOLARCITY INC. MVERhR: 4082504470 PV 6 6/14/2013 :(sso)638-1028 F:(650)638-1029 POWER—ONE # AURORA PVI-3.0—OUTD—S—US—Z THREE LINE DIAGRAM (8118)-SOL-CITY(765-2489)www.solarcity.com 1. Conductor Sizing per Art 690.8(A) ELECTRICAL CALCULATIONS a. Conductor must have 30 deg. C ampacity >= 125% of continuous current. b. Conductor must have (after corrections for conditions of use) >= Module: 14 Trina TSM-245PC PA05.06 Black 222.9 Inv Pwr W PTC StrLen Voltage Drop Calculations Version 5_9.11 continuous current per Table 310.16. Inverter 1: 1 Power-One PVI3.0-S 96.0% 3,300 2,996 14 Vdrop= (Imp) * (2*Length)*(Resistance) / (Vmp) Module: 11 Trina TSM-245PC/PA05.08 Black 222.9 Imp(A) Max.Length(ft) Wire c. Evaluate conductor temperature at terminations per 110.14(C). Inverter 2: 1 Power-One PVI-3.0-S 96.0% 3,300 2,354 11 String: 7.98 80 C AWG 10 at Max Ave Hi: 85 deg F Ampacity of wire derated for conditions of termination must be >= Module: Vdropran = (7.98.9 * 160 ft *0.0012aC Ohms)W / 391 V= AveHi: p y Inverter 3: Branch: 7.98 I 0 I C AWG 10 at Max e Hi: 85 deg F continuous current*1.25. All string terminations are rated at 90' C. Module: Vdrop= (7.98 A * 0 ft *0.00124 Ohms) / 391 V= 0.00% Inverter 4: Total voltage drop in DC conductors= 0.41% 2. OCP Sizing per Art 690.8(B)(1) Inverter: 14.50 I 10 I C AWG 10 at 240V a. Round up to next size per Art 240.4(B) Total: 25 modules Total Inv Pwr 6,600 5,350 PTC Vdrop= (14.50 A * 20 ft "0.00120 Ohms) / 240 V 0.15% Photovoltaic Module Electrical Specifications: Total STC 6,125 Combined' 29.00 I 0 I E AWG 06 at 240V 3. Conductor Sizing per Art 690.8(A) Voc= 37.3 V deg F deg C Vdrop= (29.00 A * 0 ft *0.00049 Ohms) / 240 V 0.00% Vmp= 30.7 V Record Low Temp: 16 -8.88888889 Total voltage drop in AC conductors= 0.15% a. Conductor must have 30 deg. C ampacity >= 125% of continuous Isc= 8.47 A Max Average Hi Temp: 85 29.44444444 Total voltage drop in AC and DC conductors= 0.55% current. Imp= 7.98 A Tux= -0.11936 V/deg C Power-One Strings: Individual MPPT b. Conductor must have (after corrections for conditions of use) >= Tisa 3.981 mA/deg C I continuous current per Table 310.15(8)(16). String Type A and 2 Combined Strings Type A Voc Correction Method: ManufTvoc data Branch Circuit Type A 1-way wire length: 0 ft Power-One PVI-3.0S 1 strings per branch 1 1 strings per branch 2 c. Evaluate conductor temperature at terminations per Art 110.14(C). 14 Trina TSM-245PC/PA05.08 Black Inverter Min Vdc Input: 120 Vdc 8 modules per series string 6 modules per series strin Ampacity of wire derated for conditions of termination must be >= Voc= 522.2 V Min Vmp at Max Temp: 391 Vdc Voc= 298.4 V 223.8 V p y Vmp= 429.8 V Max Voc at Min Temp: 579 Vdc Vmp= 245.6 V 184.2 V continuous current*1.25. All branch terminations are rated at 75' C Isc= 8.47 A Inverter Max Vdc Input: 600 Vdc Isc= 8.47 A 8.47 A min. Imp= 7.98 A Max String Size: 14 Imp= 7.98 A 7.98 A (cont= 10.59 A Art 690.8(A)(1) 1-way wire length: 801t !cont= 10.59 A 10.59 A Art 690.8(A)(1) 4. OCP Sizing 1.a Conductor.C AWG 10 PV Wire 2.a Conductor 1:C AWG 10 PV Wire a. Round up to next size per Art 240.4(B) Conductor 2:C AWG 10 PV Wire Conductor 1:Conductor 2: 5. Conductor Sizing per Art 690.8(A) Icont*1.25=(Amps) 13.23 Icont*1.25=(Amps) 13.23 13.23 30 a. Conductor must have 30 deg. C ampacity >= 125% of continuous deg Campacity= 40 I 30 deg Campacity= 40 40 I 1.b (cont=(Amps) 10.59 2.b !cont=(Amps) 10.59 10.59 Current. Start ampacity 40 Start ampacity 40 40 Temperature derate(%=F) 0.76 Temp.derate(%=F) 0.76 0.76 b. Conductor must have (after corrections for conditions of use) >= Conduit fill derate(%4t) 1 Cndt.fill derate(%4i) 1 1 continuous current per Table 310.15(6)(16). Derated ampacity 30.40 I Derated ampacity 30.4 30.4 I Term 1 Term 2 c. Evaluate conductor temperature at terminations per Art 110.14(C). 1.c 'cont*1.25=(Amps) 13.23 Temp table 75degC 75degC Ampacity of wire derated for conditions of termination must be >_ Ampacity 40 2.c !cont*1.25=(Amps) 13.23 1 C U P E RTI NO continuous current*1.25. All inverter out ut terminations,are rated at I Ampacity 35 ,/''�/ I 75' C. p 1.d (cont*1.25=(Amps) 13.23 2.d EGC C AWG 10 C AWG �y f� +`, 122 Building Department OCP size= 15 OCP size= 15 _.,.� 6. OCP Sizing Inverter Type A Output Combined Inverter Output ; a. Round up to next size per Art 240.4(6) Power-One PVI3.O-S 1-way wire length: 10 ft Service Voltage= 240 Volts JUN 20 2013 lcont= 14.50 A Art690.8(A)(1) Total Inverter Power= 6,600 Nameplate Watts REVIE14146higtitEOGJE COMPLIANCE 7. Conductor Sizing per Art 690.8(A) 3.a Icont*1.25=(Amps) 18.13 A Art 690.8(BX1) lcont=#of im.erters*max inverter current Ad 690.8(A)(1) a. Conductor must have 30 deg. C ampacity >= 125% of continuous OCP size= 20 A Art.240.6(A) (cont=(Amps) 29.00 Reviewed By � ../ flT Current. 3.b Conductor C AWG 10 THWN-2 at 90 deg C:Table 310.16 4.a Icont*1.25=(Amps) 36.25 A Art 690.8(B)(1) (cont*1.25=(Amps) 18.13 OCP size= 40 A Art.240.6(A) 30 deg C ampacity= 40 I 4.b Conductor E AWG 06 THWN-2 at 90 deg C:Table 310.16 b. Conductor must have (after corrections for conditions of use) >= 3.c !cont=(Amps) 14.50 'cont*1.25=(Amps) 36.25 continuous current per Table 310.15(B)(16). Start ampacity 40 30 deg C ampacity= 75 I Temperature derate(%=F) 0.91 4.c Icont=(Amps) 29.00 c. Evaluate conductor temperature at terminations per Art 110.14(C). Conduit fill derate(%=#) 1 Start ampacity 75 Ampacity of wire derated for conditions of termination must be >= Derated ampacity 36.4 I Temp.derate(%=F) 0.91 continuous current*1.25. All inverter output terminations are rated at 3.d Icont*1.25=(Amps) 18.13 Cndt.fill derate(%4f) 1 Ampacity 35 Derated ampacity 68.25 I 75' C min. 3.e EGC/GEC = D AWG 08 Art.690.47(C)(3),250.166(B) 4.d Icont*1.25=(Amps) 36.25 Amoacitv 65 I CONFIDENTIALDENT1AL- THE INFORMATION HEREIN JOB NUMBER: -9501 J B 840 0 0 PREMISE OWNER: • DESCRIPTION: DESIGN: 044 giketr,I CONTAINED SHALL NOT BE USED FOR THE POON, STEVE POON RESIDENCE Elliot Law �; �, NOR ST OF ITANYONE EXCEPT SOLARCITY INC.. MOUNTING t: �/, S��a�� NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 22530 RICARDO RD 6.125 KW PV Array o PART TO OTHERS OUTSIDE THE REgPoENTS MODULES: CUPERTINO, CA 95014 ORGANIZATION, EXCEPT IN CONNECTION W11H 055 Clevvlew Way 3 THE SALE AND USE OF THE RESPECTIVE (25) TRINA SOLAR # TSM-245PC05/PA05.18 SHEET: REV DAZE San Mateo,CA sWay SOLARCITY EQUIPMENT, WITHOUT NE WRITTEN INVERTER: PAGE NAME T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. POWER-ONE # AURORA PVI-3.0-OUTD-S-US-Z 4082504470 ELECTRICAL CALCULATIONS PV 7 6/14/2013 (888)-SOL-CITY(765-2489)www.sol°rcItycom 1. Conductor Sizing per Art 690.8(A) ELECTRICAL CALCULATIONS a. Conductor must have 30 deg. C ampacity >= 125% of continuous current. b. Conductor must have (after corrections for conditions of use) >= continuous current per Table 310.16. Module: 11 Trina TSM-245PGPA05.08 Black 222.9 Inv Pwr W PTC StrLen Voltage Drop Calculations Version 5 9.11 c. Evaluate conductor temperature at terminations per 110.14(C). Inverter 1: 1 Power-One PVI-3.0-S 96.0% 3,300 2,354 14 Vdrop= (Imp) * (2*Length)*(Resistance) / (imp) Ampacity of wire derated for conditions of termination must be >= Module: 14 Trina TSM-245PGPA05.08 Black 222.9 Imp(A) Max.Length(ft) Wire continuous current*1.25. All string terminations are rated at 90' C. Inverter 2: 1 Power-One PVI-3.0S 96.0% 3,300 2,996 11 String: 7.98 80 C AWG 10 at Max Ave Hi: 85 deg F Module: X Vdrop= (7.98 A * 160 ft *0.00124 Ohms) / 307 V= 0.52% Inverter 3: Branch: 7.98 I 0 I C AWG 10 at Max Ave Hi: 85 deg F 2. OCP Sizing per Art 690.8(B)(1) Module: Vdrop= (7.98 A * 0 ft *0.00124 Ohms) / 307 V= 0.00% a. Round up to next size per Art 240.4(6) Inverter 4: Total voltage drop in DC conductors= 0.52% Inverter: 14.50 I 10 I C AWG 10 at 240V Total: 25 modules Total Inv Pwr 6,600 5,350 PTC Vdrop= (14.50 A * 20 ft *0.00120 Ohms) / 240 V 0.15% 3. Conductor Sizing per Art 690.8(A) Photovoltaic Module Electrical Specifications: Total STC 6,125 Combined 29.00 I 0 I E AWG 06 at 240V a. Conductor must have 30 deg. C ampacity >= 125% of continuous Voc= 37.3 V degF degC Vdrop= (29.00A * oft •0.00049 Ohms) / 240V 0.00% current. Vmp= 30.7 V Record Low Temp: 16 -8.88888889 Total voltage drop in AC conductors= 0.15% Isc= 8.47 A Max Average Hi Temp: 85 29.44444444 Total voltage drop in AC and DC conductors= 0.66% b. Conductor must have (after corrections for conditions of use) >= imp= 7.98 A Tvoc= -0.11936 V/deg C Power-One Strings: Parallel MPPT continuous current per Table 310.15(B)(16). Tisc= 3.981 mA/deg C I String Type A and 2 Combined Strings Type A Voc Correction Method: Manuf Tvoc data Branch Circuit Type A 1-way wire length: 0 ft strc. Evaluate conductor temperature at terminations per Art 110.14(C). Power-0One PVI-3.0-S 1 moguper ranch 1 G 11 Trina TSM-245PPA05.0e Black Inverter Min Vdc Input: 120 Vdc 11 modull per per series string Ampacity of wire derated for conditions of termination must be >= voo= 410.3 V Min Vrnpat Max Temp: 307 Vdc Voc= 410.3 V continuous current*1.25. All branch terminations are rated at 75' C Vmp= 337.7 V Max Voc at Min Temp: 455 Vdc Vmp= 337.7 V min. Isc= 8.47 A Inverter Max Vdc Input: 600 Vdc Is 8.47 A Imp= 7.98 A Max String Size: 14 Imp= 7.98 A 4. OCP Sizing (cont= 10.59 A Art 690.8(A)(1) 1-way wire length: 80 It k:ont= 10.59 A Art 690.8(A)(1) 1.8 Conductor.C AWG 10 PV Wire 2.8 Conductor 1:C AWG 10 PV Wire a. Round up to next size per Art 240.4(6) Conductor 1: 5. Conductor Sizing per Art 690.8(A) (cont*1.25=(Amps) 13.23 Icont*1.25=(Amps) 13.23 30 deg C ampacity= 40 I 30 deg C ampacity= 401 I I a. Conductor must have 30 deg. C ampacity >= 125% of continuous 1.b lcont=(Amps) 10.59 2.b lcont=(Amps) 10.59 current. Start ampacity 40 Start ampacity 40 Temperature dente(%=F) 0.76 Temp.derate(%=F) 0.76 corrections for conditions of use) >= Conduit fill derate(%=#) 1 Cndt.fill derate(%4*) 1 ' b. Conductor must have (after Dented ampacity 30.40 I Dented ampacity 30.41 I I continuous current per Table 310.15(6)(16). Term I Term 2 1.c Icont*1.25=(Amps) 13.23 Temp table 75degC 75degC c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity 40 2.c Icont*1.25=(Amps) 13.23 13.23 I Ampacity 35 35 I Ampacity of wire derated for conditions of termination must be >= 1.d k:ont•1.25=(Amps) 13.23 2.d EGC CAWG 10 Art.250.122 - continuous current*1.25. All inverter output terminations are rated at OCP size= 15 OCP size= 15 75' C. t Inverter Type A Output Combined Inverter Output 1 C U P E RTI N O Power-OOne PVI-3.0S 1-way wire length: 10 ft Service Voltage= 240 Volts ,s //'= 6. OCP Sizing ��!, ft Euiiding Department IrroM= 14.50 A Art 690.8(A)(1) Total Inverter Power- 6,800 Nameplate Watts 1-way ,� a. Round up to next size per Art 240.4(B) 3.a Icont*1.25=(Amps) 18.13 A Art 690.8(BX1) lcont=#of inverters*max inverter current Art 690.8(A)(F-.7,..,,r,�; OCP size= 20 A Art.240.6(A) (cant=(Amps) 29.00. E �y 1 Q 7. Conductor Sizing per Art 690.8(A) 3.b Conductor C AWG 10 1HWN-2 at 90 deg C:Table 310.16 4.a tont*1.25=(Amps) 36.25 A Alt 690.8(B). "I JUN 2 L" 2"1`" • a. Conductor must have 30 deg. ampacity >= 125% of continuous Icont'1.25=(Amps) 18.13 OCP size= 40A Art.240.6(A) 9 P Y30 degCampacity= 40 I 4.b Conductor EAWG 06 1HWN-2 at 90 deg C:Table 310.16 REVIEWED FOR CODE COMPLIANCE current. 3.c icont=(Amps) 14.50 (cont*1.25=(Amps) 36.25 Start ampacity 40 30 deg C ampacity= 75 1 Reviewed By `5 ,-. .///1 e, b. Conductor must have (after corrections for conditions of use) >= Temperature dente(%=F) 0.91 4.c Icont=(Amps) 29.00 Conduit fill Berate(%=#) 1 Start ampacity 75 continuous current per Table 310.15(6)(16). Derated ampacity 36.4 I Temp.dente(%=F) 0.91 3.d Icont*1.25=(Amps) 18.13 Cndt.fill derate(%=#) 1 c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity 35 I Derated ampacity 68.25 I Ampacity of wire derated for conditions of termination must be >= 3.e EGC/GEC = 0 AWG 08 Art.690.47(C)(3),250.166(B) 4.d lcont•1.25=(Amps) 36.25 P Y Ampacity 65 I continuous current*1.25. All inverter output terminations are rated at 75' C min. CONFIDENTIAL- 1HE INFORMATION HERON JOB NUMBER: J B-9 501 840 00 PREMISE OBNER: DESCRIPTION: DESIGN: `tbb�% CONTAINED SHALL NOT BE USED FOR THE POON, STEVE POON RESIDENCE Elliot Law �.. BENEFIT OF ITANYONE EXCEPT SOLARCITY INC., MOUNTING SYS1EM:gh ,/I SolarC�ty NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 22530 RICARDO RD 6.125 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS MODULESC U P E R TI N O CA 95014 ' ORGANIZATION,EXCEPT IN CONNEC110N WITH , 1HE SALE AND USE OF THE RESPECTIVE (25) TRINA SOLAR # TSM-245PC05/PA05.18 3055 aearvkw Way SOLARCITY EQUIPMENT,WI1HOUT THE WRITTEN PAGE NAME SHEET: REV DAIS Sm Mateo,CA 94402 PERMISSION OF SOLARCITY INC. INVERTER' ' 4082504470 PV 8 6/14/2013 •(650)638-1028 F:(650)638-1029 POWER-ONE # AURORA PV1-3.0-OUTD-S-US-Z ELECTRICAL CALCULATIONS (888)-SOL-CITY(765-2489)www.solaraty.com Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT (C) MAXIMUM AC _ WARNING A (AC) (POI) (P01) Per Code: OPERATING CURRENT Per Code: Per Code: CA Fire Guidelines MAXIMUM AC _ CEC 690.54 INVERTER OUTPUT NEC 690.64.B.7 V OPERATING VOLTAGE CONNECTION Label Location: DO NOT RELOCATE THISOVERCURRENT PHOTOVOLTAIC DC (DC) (INV) DEV CE DISCONNECT Per Code: CEC 690.14.C.2 Label Location: PV SYSTEM (AC) (P01) DISCONNECT FOR Label Location: UTILITY OPERATION WARNING (DC) (INV) Label Location: Per Code: MAXIMUM POWER-_A (DC) (INV) ELECTRIC SHOCK HAZARD CEC 690.35(F) POINT CURRENT(Imp) Per Code: THE DC CONDUCTORS OF THIS MAXIMUM POWER- PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN POINT VOLTAGE(Vmp)_V CEC 690.53 UNGROUNDED AND INVERTER IS MAXIMUM SYSTEM Label Location: MAY BE ENERGIZED VOLTAGE(Voc)_V WARNING (AC) (POI) UNGROUNDED SHORT-CIRCUIT A Per Code: CURRENT(Isc) ELECTRIC SHOCK HAZARD CEC 690.17 DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label Location: WARNING (DC) (CB) Per Code: ELECTRICAL SHOCK HAZARD CEC 690.17 Label Location: DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND PHOTOVOLTAIC POINT OF (P01) LOAD SIDES MAY BE ENERGIZED INTERCONNECTION Per Code: IN THE OPEN POSITION WARNING: ELECTRIC SHOCK DC VOLTAGE IS HAZARD. DO NOT TOUCH CEC 690.54; CEC 690.17 ALWAYS PRESENT WHEN TERMINALS.TERMINALS ON SOLAR MODULES ARE BOTH THE LINE AND LOAD SIDE EXPOSED TO SUNLIGHT MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. PV POWER SOURCE Label Location: MAXIMUM AC A DC INV OPERATING CURRENT WARNING (DC) ) MAXIMUM AC V Per Code: OPERATING VOLTAGE ELECTRIC SHOCK HAZARD CEC 690.5(C) CUPERTINO IF A GROUND FAULT IS INDICATED ti '. NORMALLY GROUNDED -� Building Department CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED '/ .' ' Label Location: I ,:' • JUN 2 0 2013 CAUTION (D) (POI) Per Code: REVIEWED FOR CODE COMPLIANCE PHOTOVOLTAIC SYSTEM CEC 690.64.B.4 Label Location: CIRCUIT IS BACKFED PHOTOVOLTAIC AC (AC) (P01) (AC): AC Disc&inectwea By �.F-7N ..1A7,--/./ Per Code: (C): Conduit DISCONNECT (CB): Combiner Box CEC 690.14.C.2 (D): Distribution Panel j Label Location: (DC): DC Disconnect CAUTION (P01) (IC): Interior Run Conduit DUAL POWER SOURCE Per Code: (INV): Inverter With Integrated DC Disconnect SECOND SOURCE IS CEC 690.64.B.4 PHOTOVOLTAIC SYSTEM (LC): Load Center (M): Utility Meter (P01): Point of Interconnection CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR %b 14 ....I3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED .6- San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, SC - CA Label Set 1.4i �+�� T:(650)1 638-10282 F.(650)638-1029 EXCEPT IN CONNECTION W1TH THE SALE AND USE OF THE RESPECTIVE /� o I� '� (SSS)-SOL CITY(765-2489)wwwsolarcity.mm SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. mono multi solutions Trinamount II FOR PITCHED ROOF TSM-PC05/ PA05.18 mono multi solutions ELECTRICAL DATA STC TSM-225 TSM-230 TSM-235 TSM-240 TSM-245 DIMENSIONS OF PV MODULE TSM-PCOS/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 • Peak Power Watts-Nam(Wp) 225 230 235 240 245 938 10 YEAR A R Power Output Tolerance-Pwu(%) 0/.3 0/.3 01+3 0/+3 01+3 Trinamount II N,o - Maximum Power Voltage-V w(V) 29.4 29.8 30.1 30.4 30.7 PRODUCT WARRANTY FOR MODULE MoxmumPowercunent-1wc(A) 7.66 7.72 7.81 7.89 7.98 r.�TrEnasolar AND MOUNTING SYSTEM I Open Circuit Voltage-Voc(V) 36.9 37.0 37.1 37.2 37.3 FOR PITCHED ROOF Short Circuit Ceunent-bc(A) 8.20 8.26 8.31 8.37 8.47 5X Module EFficiency.I (%) 13.7 14.1 14.4 14.7 15.0 FASTER TO INSTALL AL .IA il Values of Standard Test Conditions SIC(Air Moss AMI.S,Irradiance 1000W/m'.Cell Temperature 25°C). ULTRA LOW ELECTRICAL DATA @ NOCT TSM-225 TSM-230 TSM-235 TSM-240 TSM-245 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.1 8 RESISTANCE - Mabmum Power(WI 64 168 172 175 27.7 178 9 ® Maximum Power Voltage(V) 26.9 27.1 27.4 27.8 GROUND BOND CONNECTION Maximum Power Current(A) 6.12 6.20 6.27 6.32 6.41 10X BETTER THAN UL MINIMUM CRITERIA o° x•«E Open Circuit Voltage(V) 33.8 33.9 34.0 34.1 34.2 o-ow.Neoie Short Circuit Current(A) 6.62 6.68 6.70 6.75 6.83 .....` _ ■ y - - NOCT:Irradiance at 800W/m2,Ambient Temperature 20°C.Wind Speed IM/s. 1 ,�,„\ ' ` - �•...� Back View l 1 t "' MECHANICAL DATA t • ti• `� `Y • Solar cells Multicrystaltine 156 x 156mm(6 inches) Cell orientation 60 cells(6 x 10) 'h� `� � •` Module dimension 1650 x 992 x 40mm(64.95.39.05.1.57 inches) \t • j •, s " \ Weight 20.3kg(44.5 Ib) 't 1 " "L Glass High transparancy solar glass 3.2mm(0.13 inches) % s M Frame Anodized aluminium alloy \. \k ',,.. u J-Box IP 65 rated „ •"-�b A-A Cables/Connector Photovoltaic Technology cable 4.0mm2(0.006 inches'). ' 1100mm(43.3 Inches).MC4/H4 I-V CURVES OF PV MODULE TSM-230PC05/PA05.18 9m C PERTINO 000w/m i a; -> 8?"I TEMPERATURE RATINGS I.I -;`,7,-,..iBuildin• Department :n. m Nominal Operating Cell 46°C(±2°C) 1 .at 6F' Temperature(NOCT) I •1 5� - . __ .: JUN 2 0 203 mio 1 4� "_ mperature Coefficient of PMAx -0.43%/°C i li: _ r. sy, "" Temperature Coefficient of Voc -0.32%/°C 340 2oow/m 2°' \li �J Temperahxe Coefficient of lsc °.047%/°0 , EVIEWED FOR CODE I OMPLIANCE SUITABLE FOR COMBINING PV MODULE EXPERTISE WITH A HIGHLY o - - 01 _ INNOVATIVE MOUNTING SYSTEM SOLUTION. °m '�° ge Som 4om Reviewed By �- �7�'r� Voltage IV) MAXIMUM RATINGS oCOMPOSITION SHINGLE Operational Temperature -40-+85°C INW Trina Solar is introducing Trinamount-the fastest,easiest and least Maximum System Voltage 1000V DC(IEC)/600V ro expensive way to mount PV modules onto residential and commercial DC(UL) rooftops.With a series of drop-in and quarter-turn connections on a Max Series Fuse Rating 15A @ TRAPEZOIDAL METAL specialized module frame,this mounting solution installs up to 5 times CERTIFICATION X faster than conventional mounting systems.Trinamount connects directly to the module frame,eliminating the need for long rails. C E ISO PV LE i0 OWWARRANTY °r / STANDING SEAM ROOF By drastically reducing the number of parts,cost of materials and rn 10 year workmanship warranty R installation time,Trinamount offers the optimal solution for residential 0�E1)us �• 25year linea pesfonnancewananty wr and commercial installations. (Please refer to product warranty for detais) 2 ,aMP41B Q � Trinasolar W Trinasolar F,° ev CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. The power behind the panel eoppP5 The power behind the panel ib 2011 Trina Solar Limited.All rights reserved.Specifications included in this dotasheet are subject to change without notice. Powe-one= `l Renewable Energy Solutions AURORA TECHNICAL DATA VALUES PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-4.2-OUTD-US Nominal Output Power W 3000 3600 4200 Maximum Output Power W 3000 3300.". 3300"" 3600 4000'" 4000"" 4200 4600". 4600'" O Rated Grid AC Voltage V 208 240 277 208 240 277 208 240 277 Input Side(DC) = Number of Independent MPPT Channels 2 2 2 P1/1-3.0-TL Q Maximum Usable Power for Each Channel W 2000 3000 3000 1% Maximum Maximum Voltage(Vmax) V 600 600 600 0 Start-Up Voltage(Vstart) V 200(adj.120-350) 200(ad).120-350) 200(adj.120-350) P Y`,I-3•6-TLce D Full Power MPPT Voltage Range V 160-530 120-530 140-530 Q Operating MPPT Voltage Range V 0.7xVstart-580 0.7xVstart-580 0.7xVstart-580 Maximum Current(Idcmax)for both MPPT in Parallel A 20 32 32 PVI-4.2-TL Maximum Usable Current per Channel A 10 16 16 Maximum Short Circuit Current Limit per Channel A 12.5 20 20 Number of Wire Landing Terminals Per Channel 2 Pairs(1 on-S version) 2 Pairs(1 on-S version) 2 Pairs(1 on-S version) GENERAL SPECIFICATIONS Array Wiring Termination Output Side(AC) Terminal block,Pressure Clamp,AWG10-AWG4 OUTDOOR MODELS Sp"`- Split- Split- 0/3W 10/2W Adjustable Voltage Range(Vmin-Vmax) V 183-228 211-264 244-304 183-228 211-264 244-304 183-228 211-264 244304 4- 6 Grid Frequency Hz 60 60 60 Adjustable Grid Frequency Range Hz 57-60.5 57-60.5 57-60.5 Maximum Current(lacmax) ARMs 14.5 14.5 12 17.2 16 16 20 20 20 The most common residential inverter is the ideal size for an average- Power armor >0.995 >0.995 >0.995 Total Harmonic Distortion At Rated Power % <2 <2 <2 sized family home. This family of single-phase string inverter Grid Wiring Termination Type Terminal block,Pressure Clamp,AWG10-AWG4 complements the typical number of rooftop solar panels,allowing Protection Devices Input home-owners to get the most efficient energy harvesting for the s»�y�/y+p1y� Reverse Polarity Protection Yes Yes Yes ly�'h.�C//f _ 1f""t Over-Voltage Protection size of the property.This rugged outdoor inverter has been designed g Type Varistor,2 for each channel Varistor,2 for each channel Varistor,2 for each channel PV Array Ground Fault Detection Pre start-up Riso and dynamic GFDI(Requires Floating Arrays) as a completely sealed unit to withstand the harshest environmental Output conditions. Anti-Islanding Protection Meets UL 1741/IEE1547 Meets UL 1741/IEE1547 Meets UL 1741/IEE1547 requirements requirements requirements Over-Voltage Protection Type Varistor,2(Li-L,/Li-G) Varistor,2(Li-L,/Li-G) Varistor,2(Li-L,/Li-G) One of the key benefits of the Uno family of single-phase inverters ) Maximum AC OCPD Rating A 20 20 15 25 20 20 25 25 25 is the dual input section to process two strings with independent MIIINIIIIIIIMINEMIIIMINIIM Efficiency ) Maximum Efficiency % 96.9 97 97 MPPT especially useful for rooftop installations with two different CRC Efficiency % 96 96 96 orientations(ie East and West).The high speed MPPT offers real-time r Operating Performance Stand-by Consumption Woo <8 <8 <8 power tracking and improved energy harvesting. .. Night time consumption Woo <0.6 <0.6 <0.6 Communication The transformerless operation gives the highest efficiency of up to ) User-Interface 16 characters x 2 lines LCD display Remote Monitoring(1xRS485 incl.) AURORA-UNIVERSAL(opt.) 97.0%. The wide input voltage range makes the inverter suitable to Wired Local Monitoring(1xRS485 incl.) PVI-USB-RS485_232(opt.),PVI-DESKTOP(opt.) low power installations with reduced string size. Wireless Local Monitoring PVI-DESKTOP(opt.)with PVI-RADIOMODULE(opt.) Environmental ' CUhERTINO Ambient Air Operating Temperature Range °F(°C) -13 to+140(-25 to+60)with -13 to+140(-25 to+fi0)with -13 to+1g0(25to with o derating above 131(55) derating above 131(55) derating above-",1% 5) Q 1.)I I�l n Ambient Air Storage Temperature Range °F(°C) -40 to 176(-40 to+80) -40 to 176(-40 to+80) -40 to 176(,atop+0) 9 Department, Relative Humidity %RH 0-100 condensing 0-100 condensing 0-100 condensing Acoustic Noise Emission Level db(A)@1m <50 <50 V <50 ��� Maximum Operating Altitude without Derating ft(m) 6560(2000) 6560(2000) 6560(2000),,i 0 2013 Mechanical Specifications -- -- -- - --- - - .. Enclosure rating NEMA4X NEMA4X NEMA4X • Each inverter is set on specific grid codes which can be selected in the field Cooling Natural Convection Natural Convection gel et0 F j R CODE COMPLIANCE Dimensions(H x W x D) in(mm) 33.8 x 12.8 x 8.7(859 x 325 x 222)-S Version • Single phase output Weight Ib/(kg) <47.3(21.3)-S version <47.3(21.3)-S version <47.3(21.3)-S version • Dual input sections with independent MPPT,allows optimal energy harvesting from two sub-arrays oriented in Mounting System wall bracket wall bracket wallbracbee. 3v _..5. q �� different directions Conduit Connections... Trade size KOs:(2ea x 1/2")and Trade size KOs:(2ea x 1/2")and Trade size KOs:(2ea 01/2")and (2ea x 1-1/C3 places side,front, (2ea x 1-1/4°3 places side,front, (2ea x 1-1/4",3 places side,front, • Wide input range rear) rear) rear) DC Switch Rating-(Per Contact) AN 25/600 25/600 25/600 • High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting safety • Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across Isolation Level Transformerless(Floating Array) Transformerless(Floating Array) Transformerless(Floating Array) Safety and EMC Standard UL 1741,CSA-C22.2 N.107.1-01 UL 1741,CSA-C22.2 N.107.1-01 UL 1741,CSA-C22.2 N.107.1-01 the entire input voltage and output power range Safety Approval ,cSA,, ,CSA,, ,CSA„, • Outdoor enclosure for unrestricted use under any environmental conditions Warranty • Integrated DC disconnect switch in compliance with international Standards(-S Version) Standard Warranty years 10 10 10 Extended Warranty years 15&20 15&20 15&20 • RS-485 communication interface(for connection to laptop or datalogger) Available Models • Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP Standard-Without DC Switch and Wiring Box PVI-3.0-OUTD-US PVI-3.6.OUTD-US PVI-4.2-OUTD-US With DC Switch and Wiring Box PVI-3.0-OUTD-S-US PVI-3.6-OUTD-S-US PVI-4.2-OUTD-S-US 'nil da..s subject to change without notice ..Capability enabled at nominal AC voltage and with sufficient DC power available _, .AURO': UNO_ .1 ,_,.>,.- .. _ .«When equipped with optional DCSwitch and Wiring Box AURORAUNO 3 o CSA INTERNATIONAL Certificate of Compliance Certificate: 2096477 Master Contract: 173688 Project: 2439385 Date Issued: July 19,2011 Issued to: Power-One,Inc 740 Calle Plano Camarillo,CA 93012 USA Attention:Robert White The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C'and 'US'for Canada and US or with adjacent indicator 'US'for US only or without either indicator for Canada only. Rob-}Eevnp$toc,7v Issued by: Rob Hempstock,AScT. C US PRODUCTS CLASS 531109 -POWER SUPPLIES-Distributed Generation Power Systems Equipment CLASS 531189 -POWER SUPPLIES-Distributed Generation-Power Systems Equipment -Certified to U.S.Standards Utility Interactive Inverter,Models PVI-4.2-OUTD-US,PVI-3.6-OUTD-US,PVI-3.0-OUTD-US,PVI-4.2- OUTD-S-US,PVI-3.6-OUTD-S-US,PVI-3.0-OUTD-S-US,PVI-4.2-OUTD-US-W,PVI-3.6-OUTD-US-W and PVI-3.0-OUTD-US-W;provided with two DC input channels,permanently connected. C U For details related to ratings,reference should be made to the CSA Certification Record,Appendix 1 or the Building T�N a Descriptive Report. Department JUN 2e 2013 APPLICABLE REQUIREMENTS CSA-C22.2 No.107.1-01 - General Use Power Supplies REVIEWED FOR CODE COMPI DANCE UL Std No. 1741-Second Edition - Inverters,Converters,Controllers and Interconnection System Equipment Reviewed By. for Use With Distributed Energy Resources(January 28,2010) DQD 507 Rev.2009-09-01 Page:1 A Y Intertek AUTHORIZATION TO MARK Intertek AUTHORIZATION TO MARK I This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing TSM-200PA05,TSM-205PA05,TSM-210PA05,TSM-215PA05,TSM-220PA05,TSM-225PA05,TSM- Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing 230PA05,TSM-235PA05,TSM-240PA05,TSM-245PA05 and TSM-250PA05. Report. TSM-200PA05.05,TSM-205PA05.05,TSM-210PA05.05,TSM-215PA05.05,TSM-220PA05.05,TSM- This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may bei 225PA05.05,TSM-230PA05.05,TSM-235PA05.05,TSM-240PA05.05,TSM-245PA05.05 and TSM- applied only at the location of the Party Authorized To Apply Mark. J 250PA05.05. Applicant: Trina Solar Ltd Manufacturer: Changzhou Trina Solar Energy Co.,Ltd. TSM-200PA05.10,TSM-205PA05.10,TSM-210PA05.10,TSM-215PA05.10,TSM-220PA05.10,TSM- ' 225PA05.10,TSM-230PA05.10,TSM-235PA05.10,TSM-240PA05.10,TSM-245PA05.10 and TSM- Address: No.2 Tian He Road,Electronic Park, Address: No.2 Tian He Road,Electronic Park, 250PA05.10. New District,Changzhou,Jiangsu New District,Changzhou,Jiangsu TSM-200PA05.15,TSM-205PA05.15,TSM-210PA05.15,TSM-215PA05.15, Country: China Country: China Models: TSM-220PA05.15,TSM-225PA05.15,TSM-230PA05.15,TSM-235PA05.15, Contact: Ms.Lihua Yin Contact: Ms.Lihua Yin TSM-240PA05.15,TSM-245PA05.15 and TSM-250PA05.15. Phone: +8651968879039 Phone: +8651968879039 FAX: +8651968879006 FAX: +8651968879006 TSM-200PA05.18,TSM-205PA05.18,TSM-210PA05.18,TSM-215PA05.18, Email: lihua.yin@trinasolar.com Email: lihua.yin@trinasolar.com TSM-220PA05.18,TSM-225PA05.18,TSM-230PA05.18,TSM-235PA05.18, Party Authorized To Apply Mark: Same as Manufacturer TSM-240PA05.18,TSM-245PA05.18 and TSM-250PA05.18. Report Issuing Office: Menlo Park,CA,USA Control Number: 4003042 Authorized by: Chi TSM-155DA01,TSM-160DA01,TSM-165DA01,TSM-170DA01,TSM-175DA01, illiam T.S rr,Certification Manager TSM-180DA01,and TSM-185DA01. (J TSM-155DA01.05,TSM-160DA01.05,TSM-165DA01.05,TSM-170DA01.05, TSM-175DA01.05,TSM-180DA01.05,and TSM-185DA01.05. A C Us ,___ Intertek � This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark Is for the exclusive use of Intertetes Client and Is provided pursuant to the Certification agreement between Nortek and its Client.Intertek's responsibility and liability are looted to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Murk and then only in its entirety.Use of Intertek's Certification mark is restricted to the conditions laid out In the agreement and in this Authorization to Mark.Any further use of the Intertek name for the sale or advertisement of the tested material,product or service must • first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 165 Main Street,Cortland,NY 13045 CUP'Ei 'INC? Telephone 800-345-3851 or 607-753-6711 Fax 607-756-6699 'i Standard for Flat-Plate Photovoltaic Modules and Panels UL 1703-Third Edition,March 15,2002,with `�/ Building Department revisions through May 23,2011 W Standard(s): - _ . :°r JUN 2 0 2013 Requirements for Flat-Plate Photovoltaic Modules and Panels,ULC/ORD-C1703-01-First Edition, ammendeOctober 2001 REVIEWED FOR CODE COMPLIANCE Photovoltaic Product: Flat Plate Photovoltaic Modules Brand Name: Trina Solar -- Reviewed By ," N ,2j,47- ATM for Report SH11031298-001 Page 1 of 2 ATM Issued:19-Jul-2011 ATM for Report SH11031298-001 Page 2 of 2 ATM Issued:19-Jul-2011 ED 8.9.4(8-Jan-10)Mandatory ED 8.9.4(8-Jan-10)Mandatory E r