Loading...
13060169 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 21743 CASTLETON ST CONTRACTOR:HIGHLIGHT SOLAR PERMIT NO:13060169 OWNER'S NAME: DEBARGHA MUKHERJEE 3554 PARKLAND AVE DATE ISSUED:06/20/2013 OWNER'S PHONE: 4082345956 SAN JOSE,CA 95117 PHONE NO:(408)489-9273 13 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL COMMERCIALS License Class ,, c L4 Lia#11. C?4,n'a (8.670 KW)INSTALL 34 ROOF MOUNTED PV PANELS Contractor Yi►G L Date 3 I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force.and effect.. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3,700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$33000 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:35618070.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and.county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned.property for inspection purposes. (We)agree to save 180 DAYS F T CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the Date granting of this permit. Additionally,the applicant understands and will comply with all non-point source regulations per.the Cupertino Municipal Code,Section 9.18. // ROOFS: Signature Date In � �I3 All roofs shall be inspected prior to anyny roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER:DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure isnot intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this.permit'is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Sections 25505,25533,and 25534. Section 3700 of the Labor Code,for theerformance of the work for which this / _ p Owner or authorized agent: - Date: permit is issued. I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If,after making this certificate of exemption,I become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT.CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date ALTERNATIVE ENERGY PERMIT APPLICATION 10 COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION 6\� A 10300TORRE AVENUE•CUPERTINO,CA 95014-3255 O CUPERTINO (408)777-3228•FAX(408)777-3333•building(ftypertino.orcl \� PROJECT ADDRESS A f -7L 2 /' �Tj e &l s �Gy ,©1 APN# 1 5,67 ©4-0 OWNER NAME q�G 1 -r�J��I/ "��1Ge r- PHONEyo�-a3�r-S9.�b E-MAIL 17 CQJ�1 0aM�^CI' STREET ADDRESS •�`J �T�� �Jr CITY,STATE,ZIP/�_ _qe.. I / 91501�), FAX "✓",11 (J CONTACT NAME F,/,p �f�O�1 t VlR 1�•'1 PHONE/'D 0 `!L ( E-MAIL �1 l q h d f. STREET ADDRESS �Qk1/Q4q� CITY,STATE Z�II &� _/1 FAX ❑OWNER ❑ OWNER-BUILDER ❑ OWNER AGENT CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑TENANT CONTRACTORNA'M\\E �� r LICE �E NUMBER-7 LICENSE TYPE 4 BUS.LIC# COMPANY NAM /'i 5 Vl CLQ IG�E-MAIL ' L4 o �tt( L f g FAX STREET ADI e._� J CITY,STATA� PHONE ^4 ARCHITECT/ENGINEER NAME -FLICENSE NUMBER __ BUS.LIC# `-- COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP --- PHONE USE OF SFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes P(I No FLOOD ZONE ❑ Yes jk NO iK SOLAR PANELS 1 ❑ ELECTRIC VEHICLE CHARGING STATION I ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS. NUMBER OF PANELS/UNITS:,j Lf KILOWATTS(COMMERCIAL ONLY): O _70 ry!, TOTAL VALUATION: DESCRIPTION OF WORKyz C VED B By my signature below,I certify to each of the following: I am the property owner or authoriz gent to act on the p r s ehalf I have read this application and the information I have provided is correct. I have read the Description ofWolk and verify it is acc te. I agree to comply with all applicable local ordinances and state laws relating to building construction. I authorize representatives of Cupertino to enter the above-identified property for inspection purposes. Signature of Applicant/Agent: Date: 0��%�� 422 J o ( 3 SUPPLEMENTAL INFORMATION REQUIRED OFFICE USE ONLY w R-TII&COUNTER ❑ EXPRESS V ❑ STANDARD V ❑ LARGE a ❑ MAJOR PVApp_2011.doe revised 03/16/11 CITY OF CUPERTINO FEE ESTIMATOR—BUILDING DIVISION ADDRESS: 21743 CASTLETON ST DATE: 06/20/2013 REVIEWED BY: MELISSA APN: MELISSA BP#: *VALUATION: 1$33,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration/ Repair PENTAMATION PRIMARY SOLAR-RES USE: SFD or Duplex PERMIT TYPE: i WORK 8.670 kW INSTALL 34 ROOF MOUNTED PV PANELS SCOPE k' tech Plan CheckPhimb.Plan Check Elec.Plan Check Wech.PermitFee: Plumb.Permit Fee: Elec. Permit Fee: Other.Wech.Insp. Other Plumb Insp. Other Elec.Insp. Alech.ln.sp..Fee: Plumb. hislr.Fee: Elec.Insp.T ce: NOTE:This estimate does not include fees due to other Departments(Le.Planning,Public Works,Fire,Sanitary Sewer District,School District,eta). These fees are based on the preliminary information available and are only an estimate. Contact the Dept for addn'1 info. FFEE ITEMS(Fee Resolution 11-053 E . 7ff 11112) FEE QTY/FEE MISC ITEMS n Check Fee: $0.00 1 # Alternative Energy System pp/.PC Fee: Q Reg. OT O.Q hrs $0.00 $219.00 IPHOTOVRES Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Suppl.Insp.Fee:Q Reg. ® OT ro.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Consiruction Tax: Adrninistr°ative.Fee: Work Without Permit? ®Yes No $0.00 Advanced Planning Fee: $0.00 Select a Non-Residential Building or Structure Travel Documentation Fees: � Strong Motion Fee: 1BSEISMICR $3.30 Select an Administrative Item Bldg Stds Commission Fee: 1BCBSC $2.00 Ug $5.30 $219.00 ° _ . �aOT $224.30 � - Revised: 04/29/2013 Building Department City Of Cupertino 10300 Torre Avenue Cupertino, CA 95014-3255 Telephone: 408-777-3228 C O P E RT I N O Fax: 408-777-3333 CONTRACTOR/SUBCONTRACTOR LLAT;" JOB ADDRESS: 217,43 fi »� ek PERMIT# r ,,0,6&69 OWNER'S NAME: 0E Ker- PHONE# GENERAL CONTRACTOR: M�L� ,,� A.,- BUS1NESS LICENSE# ADDRESS: 3 - a ,/Gj GA CITY/ZIPCODE: *Our municipal code requires all businesses working ig the city to have a City-.of Cupertino business license. NO' BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE: OBTAINED A rCITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: Sig ture D to Please check applicable subcontractors and complete the following information SUBCONTRACTOR BUSINESS NAME .BUSINESS LICENSE# Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring/Carpeting Linoleum/Wood Glass/Glazing Heating Insulation Landscaping Lathing Masonry Painting/Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile Owner/Contractor Signature Date z, LTS I GENERAL NOTES 6.CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF NERGY INC. 1.ALL ELECTRICAL MATERIALS AND EQUIPMENT SHALL BE NEW AND LISTED PULL BOXES OF JUNCTION BOXES/COMBINER BOXES PER APPROPRIATE CA ST. BUILDING A-6 BY RECOGNIZED ELECTRICAL TESTING LABORATORY. NEC REQUIREMENTS. TH , CA 9 7 3 1 1 CUSTOM MADE EQUIPMENT SHALL HAVE COMPLETE TEST DATA PHOTOVOLTAIC SYSTEM SUMMARY SJ 678-9699 EXT.DO I SUBMITTED BY THE MANUFACTURER ATTESTING TO ITS SAFETY. 7.SEE PROVIDED CUT SHEETS FOR ADDITIONAL EQUIPMENT RTUNEENERGV.NET SPECIFICATIONS. SYSTEM SIZE:8.67 kW DC 2.NO PIPING,DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL MODULES:(34)CANADIAN SOLAR CS6P-255M EQUIPMENT SHALL BE PERMITTED TO BE LOCATED WITHIN THE DEDICATED 8.WIRING MATERIALS SHALL BE SUITABLE FOR THE SUN EXPOSURE AND MODULE MAX POWER(P/MAX):255W !. SPACE ABOVE THE ELECTRICAL EQUIPMENT. WET LOCATIONS.FIELD APPLIED PROTECTIVE COATINGS ARE NOT INVERTER:(34)ENPHASE M215-60-2LL-S22/S23 PROJECT TEAM Fortune Energy ACCEPTABLE RECOMMENDED MOUNTING SYSTEM:FORTUNE DUAL RACK SOLAR SYSTEM COORDINATOR 3.OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED. FORTUNE ENERGY INC, 9.JUNCTION,PULL AND OUTLET LOCATED BEHIND MODULES SHALL BE SO ARRAY TILT:17 DEGREES 21029 ITASCA STREET,BUILDING A-B, 4.ALL METALLIC EQUIPMENT SHALL BE GROUNDED. INSTALLED THAT WIRING CONTAINED IN THEM CAN BE RENDERED AZIMUTH:200 DEGREES CHATSWORTH CA,91311 ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF MODULE(S)SECURE BY OFFICE:816.678-9699 v 1 O 5.ALL SPECIFIC WIRING IS BASED ON THE USE OF COPPER. REMOVABLE FASTENERS AND CONNECTED BY A FLEXIBLE WIRING ELECTRICAL INFORMATION SYSTEM. UTILITY COMPANY:PG&E ENGINEERS 6.DO NOT SCALE DRAWINGS.IF UNABLE TO LOCATE DIMENSIONS FOR ANY (NEC 690.34) MAIN SERVICE AMPERAGE:100A FORTUNE ENERGY INC,DESIGN DEP. O ITEM OF WORK,CONSULT ARCHITECT/ENGINEER FOR DIRECTIONS BEFORE 21029 ITASCA STREET,BUILDING A-B, BUILDING INFORMATION CHATSWORTH CA,9131 PROCEEDING.THE DRAWING ARE BASED ON GOOGLE MAP,AND THEREFORE 10.IN AN UNGROUNDED PHOTOVOLTAIC SYSTEM,THE POWER SOURCE u THE ROOF SLOPE DIMENSIONS MAY NOT ACCURACY.CONTRACTOR TO SITE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH JUNCTION OCCUPANCY:RESIDENTIAL OFFICE:818-678-9699 EXT 801 L, , \ VERIFY ALL ROOF OBSTACLES AND ALL REQUIRED CLEARANCES WITH AHJ(S) BOX,COMBINER BOX,DISCONNECT AND DEVICE WHERE THE ROOF:COMP.SHINGLE T� � + r W v PRIOR UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE:"WARNING TO INSTALLATION. ELECTRIC SHOCK HAZARD.THE CURRENT CIRCUIT CONDUCTORS OF THIS c ^ O LL; PHOTOVOLTAIC POWER SYSTEM ARE UNGROUNDED BUT MAY BE SHEETINDEXNOTES TLE PLAN,GENERAL � tr 7.DIMENTIONS BEFORE ORDERING OR FABRICATING ANY MATERIAL ROOF ENERGIZED WITH RESPECT TO GROUND DUE TO LEAKAGE PATHS AND T1 TITLE SYSTEMS GENERALMMARY DIMENSION ON THIS DRAWING SET MAY NOT BE TO ACCURACY AND MAY /OR GROUND FAULTS." P�7" — NEED TO CHANGE THE NUMBER OF PV MODULES,AND LAYOUT (NEC 690.35(F)) Al PANEL AND RACKING LAYOUT E1 SINGLE LINE DIAGRAM _ - - - C� CONFIGURATION UPON SITE VERIFICATION. u i 11.ALL PHOTOVOLTAIC MODULES AND ASSOCIATED EQUIPMENT AND E2 LABELS AND SPEC SHEETS _[ 8.CONTRACTORS SHALL OBTAIN ELECTRICAL PERMITS AND SHALL WIRING MATERIAL SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. Y COORDINATE ALL INSPECTIONS,TESTING COMMISSIONING AND M w ACCEPTANCE WITH THE CLIENT,UTILITY CO.AND CITY INSPECTORS AS ADDITIONAL REQUIREMENTS NOTE: _ NEEDED.CALL INSPECTIONS UPON INSTALL RACKING SYSTEM. 1.SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED THIS DRAWINGS ARE SUBJECT TO AN APPROVAL OF THE BUILDING C'! 9.THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATIONS OF DISCONNECTING MEANS THAT PREVENTS ANTI-ISLANDING DEPARTMENT,FIRE MARSHAL,UTILITY COMPANY AND OTHER AGENCIES SERVICE POINTS AND SERVICE SIZES WITH THE SERVING UTILITY COMPANY (PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE) AUTHORITY HAVING JURISDICTION(AHJ). PLUPL&NS 01 "T N U AND COMPLY WITH ALL THE UTILITY COMPANIES REQUIREMENTS.IF THE BY THE ACT OF SUBMITTING A BID PROPOSAL FOR WORK,THE V 1Lu SOLAR BACK FED BREAKER IS OVER THE BUS SIZE 20%LIMIT,CONTRACTOR 2.OVERCURRENT PROTECTION FOR BOTH ALTERNATING AND DIRECT CONTRACTOR HAVE REVIEWED THE PLANS THOROUGHLY AND ACCEPT CMCKUD BY C SHALL INCLUDE THE COST TO REPLACE MAIN BREAKER OR ENLARGE THE CURRENT MUST BE INSTALLED IN THE INVERTER OR FIELD INSTALLED AT FULL RESPONSIBILITY OF PLAN CORRECTIONS AND ASSOCIATED MAIN CAPACITY. THE TIME OF THE INSTALLATION. CONSTRUCTION COSTS REQUIRED BY AHJ. CODE SUMMARY 01kTE 10.DRAWINGS ARE DIAGRAMMATIC ONLY,ROUTING OF RACEWAYS SHALL BE 3.MAIN SERVICE PANEL MUST HAVE PERMANENT PLAQUE INDICATING A THIS PROJECT SHALL COMPLY WITH THE FOLLOWING CODES: o AT THE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SECOND POWER SOURCE IS INSTALLED,AND A DISCONNECTING MEANS 0 g SHALL BE COORDINATED WITH OTHER TRADES.IF THE ROOF MATERIAL OR MUST BE FIELD INSTALLED IN ALL UNGROUNDED CONDUCTORS AT THE 2010 CALIFORNIA BUILDING CODE fN,G � � 2 m A 0 ROOF STRUCTURE NOT ADEQUATE FOR PV INSTALLATION,CALL ENGINEER MAIN SERVICE PANEL 2010 CALIFORNIA ELECTRICAL CODE Z 0, a, u 2008 NATIONAL ELECTRICAL CODE Q N z PRIOR TO INSTALL. ALL OTHER ORDINANCES ADOPTED BY THE LOCAL GOVERNING AGEN E (y 0 N 0 11.IF THE DISTANCES FOR CABLE RUNS ARE DIFFERENT THAN SHOWN,THE C N N 1 CONTRACTOR SHALL NOTIFY THE ELECTRICAL ENGINEER TO VALIDATE THE — WIRE SIZE.FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS r k - gi n(;- DEPT. J APPROPRIATE. i' r E f 2 w ^ 0 + ! Z V 2 I 12.WHENEVER A DISCREPANCY IN QUANTITY OF EQUIPMENT ARISES ON THE �* r r 0 - x ' NOW DRAWING OR SPECIFICATIONS,THE CONTRACTOR SHALL BE RESPONSIBLE � � � y,� A CUP ERTINC� FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED y I - "; BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE r"" k+ ; - _ Building Department SPECIFICATIONS TO ENSURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCH ITECTIENGINEERS. �► " ar "� 7 0 7013 , :' 1 � SUN 13.ALL BROCHURES,OPERATION MANUALS,CATALOGS,SHOP DRAWINGS, , ., P� + A, - ETC.SHALL BE HANDED OVER TO OWNER'S REPRESENTATIVE AT THE COMPLETION OF WORK. -'� �» 1 1 R ® A " . .. k ter' f ®� `` , REVIEWED FOR CODE COMPLIANCE PHOTOVOLTAIC NOTES 1.AN INVERTER OR A MODULE IN AN INTERACTIVE PHOTOVOLTAIC SYSTEM g , w r..a, } Reviewed By SHALL AUTOMATICALLY DE-ENERGIZEITS ITS OUTPUT TO THE CONNECTED ' ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOST OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE . ,wi b � ,r"• j ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS rTy DEPS O BUILDING DMSION-CUPERTIN• +. ' BEEN RESTORED.(NEC 690.61) `• .1 2.ALL EXTERIOR ELECTRICAL METALLIC TUBING(EMT)CONDUIT FITTING APPROVEDFICE EAIIFIED' SHALL BE RAIN-TIGHT THREADLESS COMPRESSION TYPE. n This set of plans and specifications MUST be kept at the 3.MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. z job site during COnStrUCtJ�O� I nsUr.- .: 4.NAMEPLATES SHALL BE PROVIDED FOR ALL CIRCUITS IN THE SERVICE VICINITY MAP FRONT VIEW changes or alteratAtz n a U t any e Ler DISTRIBUTION AND POWER DISTRIBUTION SWITCH BOARDS,PANEL BOARDS, SCALE: NTS SCALE: NTS unarefrorn, without approval fr91# e:�T�ing Official. J08 0040-P000$-08 DISCONNECTING SWITCHES,TERMINAL CABINETS,ETC.ALL NAMEPLATES . SHALL BE PERMANENTLY ATTACHED AND BE OF SUFFICIENT CAPACITY TO The Stamping of this plan and specifications SHALL NOT T1 13 E L:k E0 UF7!I C1:7 3 T. /1LYMANI WITHSTAND THE WEATHER. be held t0 P SCALE:CH EL'k EO 5.JUNCTION BOX/COMBINER BOX HAVE TO USE COMPRESSION TYPE STRAIN an approval Of the violation .1 PPRUVED RELIEF POSITIONED FOR APPROPRIATE WATER RUN OFF. f� City Ordinance or State Law. SHEET TITLE: TITLE HHEET D PERAMT NO. / 30.6 /6 A_ NEIGHBOR D 0 I 0 Cn m n m CA) rn N r I o z z C = C32 mo I o No cl_0 rri� � D Z iii rn z m Fm] L 0 CASTLETON St yD h m 11 rq Ln �I ® r tzj a T O y e � C 0D N, H D AM L m n A = z (n m ro Z � s d s \ a ;r t ) cn0m0000 � w � _ � e 7D -n cli ma� p z d C C Z Z A m � � ncnG) G) r, a �, v -n � 2 cncnZ _ � o o m m (n p o m v v (D o m D = z Zxcc mmzm L w Z m z -+ r rn M � Zj O m , ::E m C o f n W A z m m m D z z t > D z -j M � -� 0 � rr ;ry aC A� ch m o u p —; Z r co Mi r- O � w w 4 w o m A ; C' w H� i ns `� NCA p I m cn c) z y M p + Lam' � g rl 0ca to g 9 r v G) C r- N m / G] GD'1 3 D D = 3.4-- - 1-3 H d X r 13 n -4 m D p D 3 n n � R14zv— rq � r A z IR mm y m '�RADmD r m o o qk Z r� p -'z z rqD� 0 m�n�L7 U m t CONTRACTOR: DEBARGHA MUKHERJEE RESIDENCE: T z m z m 2 ft1 O t ¢ HIGHLIGHT SEI"R IND. ,, 0 r n A y O PHONE. I-S66-926-9997 21743 CASTLETON St. �,..., i m o O LDfm-- Fs�c 1-856-2 7 3-2997 y y fl WWYY HlGHL7GHT5QLAI�.CQM CUPERTINO, CA 95014 m m PRLJ IEC'T 0CSIGNCl7: TIM ALYMANI FORTUNE ENERGY INC. 1 SINGLE LINE DIAGRAM CHATS ORTH 6T. GUILD/NGAH CHATSWQRTH CA 91 37 I OFF-ICE: (&16)'676.9699 EXT.8Q1 SCALE: NTS WE67 WWW.FORTUNEENERI3Y.NET EXISTING MAIN SERVICE PANEL Far;ai'ne 6trergy 100A MAIN BREAKER PV MODULE RATINGS @ STC STRING 1 AMBIENT TEMPERATURE 125A BUS RATING N. ffN N SOLAR MODULES ♦-�' r-I MODULE MFR: CANADIAN SOLAR HI 30°C LOW-7°C ,M, O + + + + + + + + + + + + + in MODULE MODEL: CS6P-255M - - - - - - - - - - - - EINVERTE MVOC = 37.7V 1 2 3 4 5 6 7 JUNCTION BOXVmp = 30.5V 15 16 1NEMA 4R CONDUIT w_ CABLE AC.1 z rrl V ISC = 8.87A L ,L ,N&GND) 1"EMT o h lel O Imp = 8.35A STRING 2 BARE COPPER#6 (AC) 20AMP 2P ui + + + + + + + + + + + + + + MODULE GND w Cn 4 #6 T ING CUPER I MP 2P � BARE COPPER#6 DE ''"'4: Y PV ARRAY INFORMATION 1 2 3 4 5 6 7 15 16 17 ENPHASE/RACKING GND CONDUdTOR �T�� TRUNK CABLE < M W STRING 1&2: -- - - 5 :: ria, _ ENPHASE (L1,L2,N&GND) # OF PARALLEL MODULES IN STRING: 17 TERMINATOR REVIEVV'--i- rUr< COLE COMPLIANCE m N U Voc (17) PER STRING = 37.7V * 1.14 = 42.97V _ w Vmp (17) PER STRING = 30.5V Reviewed By: J� C.1 AC. Highlight Solar Note : "Typical Wire Size" provided includes ambient temperature INVERTER RATING 2 #10 THWN-2 + 1 #10 NEUTRAL, CU and conduit fill, adjustment only. Additional derating may be needed n 1 #10 GND based on actual conditions of use; conduit location, etc. o INVERTER MFR: ENPHASE #10 RATE 90°C =40A OA, 1OAWG = 30A o y INVERTER MODEL: M215-60-2LL-S22/S23 TEMPERATURE DERATING @ 50°C =0.82 Technical notes (as applicable): v x m a DC VOLT RATING = 45V 1" EMT FILL FACTOR =0.8 1 Circuit breakers without "Line" and "Load" markings are generally " " a DC MAX INPUT CURRENT = 10.5A 40A * 0.82 * 0.8 = 26,24A > 19.13A [ ] g g y x appropriate for backfed applications per NEC 2010-690.64(B)(5). o 0 AC MAX OUTPUT POWER @ 240V = 215W OK TO INSTALL THWN-2 #10 [2] Module wiring ampacity based on conductor in free air per (NEC pF",tl„= a AC NOMINAL OUTPUT CURRENT = 0.9 A 2010-Table 310.17) [3] Minimum bus or conductor sized based on sum of ratings of all MIN WIRE AMPACITY = 0.9 * 1.25 * 17 PANELS OUTPUT CALCULATIONS source over current devices per NEC 2010-690,64(B)(2). = 19.13A PV SYSTEM MAX DC OUTPUT = 255 * 34 = 8.67 kW [4] Breaker to be located at opposite end of bus from supply feed a..A. MIN (OCPD) = 20 and requires "Do Not Relocate" marking per NEC 2010-690.64(B)(7). PV SYSTEM MAX AC OUTPUT: [5] Maximum string current with (17) 60-cell modules is 15.3A. (15.3 TRUNK CABLE (34) ENPHASE M215-60-2LL-S22/S23 x 1.25 = 19.13A) maximum AC current. (L1,L2,N,GND)#12 RATE 90°C =30A (34) CANADIAN SOLAR CS613-255M String voltage: (Nmodules X Voc X (lowtemp correction (690.7 CEC)) TEMPERATURE DERATING @ 50C =0.82 [6] CEC (705.12(D)(2)) - Supply OCPD less or equal to w+rw 30A x 0.82 = 24.6A > 19.13A PMAx (PTC RATING) PER MODULE = 232.7 W 120% of bus rating. = 125 X 120% = 150AOM OK TO INSTALL #12 THHN/THWN-2 232.7 W * 34 = 7.91 kW max. input source OCPD. ) TRUNK CABLE 7.91 kW * 96% INVERTER = 7.59 kW 100A + 20A + 20A = 140A = less than 150A max. o e wc. JOB # 0040-P0005-DB E1 PREPARED Cali B,17 al-r, ALYMANI SCALE:CHECKEo APPRiJVt U SHEET TITLE: SINGLE LINE DIAGRAM 1 TIM ALYMANI FORTUNE ENERGY INC. 27 L129 ITASCA ST. BUILDING A-B CHATSWORTH , CA 9 7 3 7 7 OFFICE: (818) 678-9699 EXT.BU I WEB: WWW,FORTUNEENERGV.NET Ir iitll mr�l�liil ForRunin e Energy IwlliiN�liilll�lll�l CONTENT: CONTENT: � I III Il�lliililllli I � o I Ili u��Iliilliilli I "SOLAR PV SYSTEM POINT OF CONNECTION" "PHOTOVOLTAIC SYSTEM" Z 6 IliiH�llilliilliil AC INPUT AMPS" "DO NOT RELOCATE THIS BREAKER" Q IIIiiNillliillNl NOMINAL VOLTAGE 240VAC z N LOCATION: I Ilii iililillillll LOCATION: POINT OF CONNECTION PANEL. o POINT OF CONNECTION PANEL. w Q I Mlilllilllil� NEC 690.64 (B)(4) W Z I NullW M = U CONTENT: CONTENT: M w ;X611-,440;,14 W25012551260M Et""` 1° "THIS PANEL FED BY MULTIPLE SOURCES" _ a ,� y, ., Temperature Charecter1a11cA CAUTION SOLAR CIRCUIT 0 "UTILITY AND SOLAR PV" 0pc 0 rt1Xi.W ' I 1r1 11 n a.; I— nJM f.Y m � `� V � L 1 � FbA 1 fW • .K 1( ,..p',+II •V+'+' 1F17G mance atlOwlrradlance LOCATION: LOCATION: a", Iq,•. ­00,l-1 MNnrneMA"t lrw•rnlw,nn ALL PANELS: SUB PANELS AND MAIN ON ALL INTERIOR AND EXTERIOR PV _ +qM Nlnno.nrn»awm •`° """°' 690.64 (B)(4) CONDUIT, RACEWAYS, ENCLOSURES, Highlight Solar CABLE ASSEMBLIES AND JUNCTION n BOXES PLACEDEVERY10"(1.1.2 Q00tRTINO Z 3wldina Department ro ro g �.. ..,.. NOTES: cc y NQ Fnphase M215 0 N JUN2021.11:.1 = m � 1.BACKGROUND: RED. cl� �' co 2 2. LETTERS: WHITE. :REVIEvvEI.J i-UK UUUE COMPLIANcE Zri - 3.FONT: ARIAL OR SIMILAR NON-BOLD. reviewed By 4. ALL LABELS SHALL HAVE CAPITAL LETTERS. INPUT 0.".100) _ MIS 00.9LLL931H23 nntl Mf ll aagLL•FFANA/°JTM.IOnlgrinl 5.M I N I M U M HEIGHT: 1-1/2" . °' 'Y.. .„•.r 6. ALL LABELS SHALL BE WEATHER RESISTANT MATERIAL (E.G ENGRAVED PLASTIC )REFLECTIVE Pas+urm".Irxwnp.:Hang 4T�M v SURFACE AND MATERIAL SUITABLE FOR EXTERIOR USE. Mn.AAFA.FWI WIIaW :[Y,aSY 7. PV BREAKER WILL BE PLACED FURTHEST AWAY FROM THE MAIN BREAKER. Mqx iIPUI Olegly m ro n OUTPUT DATA u0) 08041 YAC 07"VAC 8. DC PHOTOVOLTAIC ARRAYS SHALL BE PROVIDED WITH DC GROUND FAULT PROTECTION IN Na NU Ycnuwwu maprt IIPrr+/ .'S w NOlrnlaDylu:c�•�onl rJ1.11——10 d­ Ob A.A-1.lt 1P—O 1.11 NamnH v00n0Nrnrp)k 2011/,A9.J9Y ZA0/1r-2mv ACCORDANCE WITH ART 690.5(A) THRU (C) E•IanNtl Wllsae„ayn IIP4:k^t' :�'N-.09Y W.'al--l—,- `1005.1 9. REFER TO GENERAL NOTE ON SHEET T-1 FOR BACKFEED BREAKER SPEC. k+tagN1'roA•M".:r'anpe 5r.°05+: 6r.tl0 a'It P-11%I,T 4A6 +ORS AI"umvn­,,-20A t­1 >i 11Han aM<? •1 iu•AIn P�,-,"; Ma++nvn 0Nav1 WI W-1 IDS Nm{,OMI iCVtlgf.I.W A'mgpp SCrGNL ., �CEnnED 3 FFFICIFNCV . Q Irc JOS 0040-POOOS-DB E2 'Nt 11ANt u 06/1 8.'7.7 T. ALYMANI HEL KED SEE OWG PPRI_7\'ED SHEET TITLE: LABELS/SPEC SHEETS o� CanadianSolar irt's i CS6P is robust solar module with 60 solar cells. These modules can be used foron-grid solar k'y applications.Our meticulous design and production techniques ensure ahigh-yield, long-term performance for everymodule produced.Our rigorous quality control and in-house testing facilities f` y guarantee Canadian Solar'smodules meet thehighest quality standards possible. Best Quality a 235 quality control points in module production • EL screening to eliminate product defects N - • Current binning to improve system performance ° • Accredited Sal onia resistsnCUPERTINO Building Department Best Warra mance �kJ ��f s • 25 years worldgage j UN 2 • 100%warranty ermcoverage • Providing third RSV BVt(ypiRhgODE COMPLIANCE • Non-cancellable / j • Immediate coverage Reviewed By: F" • Insured by world top insurance companies Comprehensive Certificates • IEC 61215, IEC 61730, IEC61701 ED2, UL1703, ,. KEMCO, CEC Listed,CE,JETand MCS 9F • IS09001:2008:Quality Management System • ISO/TS16949:2009:The automotive quality management system • IS014001:2004:Standards for Environmental management system • QC080000 HSPM:The Certification for Hazardous Substances Regulations • OHSAS 18001:2007 International standards for occupational health and safety • Reach Compliance �sAU=C E . www.canadiansolar.com NNja zs! z j . 1`1111115'' 1 Nominal Maximum Power(Pmax) 235W 240W 245W 250W 255W Optimum Operating Voltage(Vmp) 30.1V 30.2V 30.3V 30.4V 30.5V .-0.45%fC a' Optimum Operating Current(Imp) 7.82A 7.95A 8.09A 8.22A 8.35A Temperature Coefficient Voc -0.35%fC - � Open Circuit Voltage(Voc) 37.2V 37.3V 37AV 37.5V 37.7V Isc 0.060*WC 3 Short Circuit Current(Ise) 8.34A 8.46A 8.61A 8.74A 8.74A Normal Operating CeIlTemperature 45t2C .".r Module Efficiency 14.61% 14.92% 1 15.23% 1 15.54% 15.85% ' Operating Temperature Maximum System Voltage 1000V IEC /600V UL A Maximum Series Fuse Rating 15A Application Classification Class AI r � ` Power Tolerance 0-+5W as,< s ` S'!Pt�'��ii'Str'r•�3�5 :3 E�,. � �r.. „ Nominal Maximum Power(Pmax) 170W 173W 177W 18OW 184W Optimum Operating Voltage(Vmp) 27.5V 27.5V 27.6V 27.7V 27.8VFy- Optimum Operating Current(Imp) 6.18A 6.29A 6.40A 6.51A 6.62A e Open Circuit Voltage(Voc) 34.1V 34.2V 34.3V 34AV 34.6V z ems,: Short Circuit Current(Ise) 6.75A 6.85A 6.97A 7.08A 7.18A ,r n. Cell Type Mono-crystalline 156 x 156mm,2or 3 Bustlers a Cell Arrangement 60(6 x 10) =0111m [ Dimensions 1638 x 982x 40mm(64.5x 38.7 x1.57in) `€" ` Weight 19kg(41.9 lbs) - . e y lf' Front Cover 3.2mm Tempered glass Frame Material Anodized aluminium alloyx AL - J-BOX IP65,3 diodes ly I 5 , Cable 4mm2(IEC)112AWG(UL),1000mm vs? Connectors MC4 or MC4Comparable s Standard Packaging(Modules per Pallet) 24pcs T e a Module Pieces per container(40 ft.Container) 672pcs(40'HQ) a 7-0 Secf°n A A a�€ 350 1 r £ 2 O I a gip'. � '� F�%d 32:;ffi36 Via. a About Canadian Solar Canadian Solar Inc.is one of the world's largest solar Canadian Solar was founded in Canada in 2001 and was companies. As a leading vertically-integrated successfully listed on NASDAQ Exchange (symbol: CSIQ) in manufacturer of ingots,wafers,cells,solarmodules and November 2006. Canadian Solar has module manufacturing solar systems, Canadian Solar delivers solar power capacity of 2.05GWand cell manufacturing capacity of 1.3GW. products of uncompromising quality to worldwide customers. Canadian Solar's'world class team of professionals works _closely with our customers to provide them with solutions for alltheir solar needs. Tei +1 519 837 1881 Fax: +1 519,137 2550 EN-Rev 3.50 Copyrlghto 2012 Canadian Solar Inc. 4 !IP 9yy 9�rb f P,t J E �. @d CUPERTINO v,= Budding Department err i REVIcV11ECt rUH ;UDE COMPLIANCE hevievved By - Maximum energy production The Enphase Energy Microinverter PRODUCTIVE - Resilient to dust, debris and shading - Performance monitoring per module System improves energy harvest, increases reliability, and dramatically -System availability greater simplifies design, installation and RELIABLE than 99.8% - No single point of system failure management of solar power systems. The Enphase System includes the -Quick and simple design, installation SMART and management microinverter, the Envoy Communications -24/7 monitoring and analysis GatewayTlm, and Enlighten®, Enphase's monitoring and analysis software. Low voltage DC SAFE - Reduced fire risk C ices M215 MICROINVERTER TECHNICAL DATA Data ! •/ ° and 60 ° ° (Ontadb Recommended input power(STC) 190-270W Maximum input DC voltage 45V Peak power tracking voltage 22V-36V Operating range 16V-36V Min./Max.start voltage 22V/45V Max. DC short circuit current 15A Max. input current 10.5A OutputData ° i Maximum output power 215W 215W Nominal output current 1.OA (arms at nominal duration) 0.9A(arms at nominal duration) Nominal voltage/range 208V/183-229V 240V/211-264V Extended voltage/range 208V/179-232V 240V/206-269V Nominal frequency/range 60.0/59.3-60.5 Hz 60.0/59.3-60.5 Hz Extended frequency range 60.0/59.2-60.6 Hz 60.0/59.2-60.6 Hz Power Factor >0.95 >0.95 Maximum units per 20A branch circuit 25(three phase) 17(single phase) Maximum output fault current 1.05 Arms,over 3 cycles;25.2 Apeak, 1.74ms duration Efficiency CEC weighted efficiency 96.0% Peak inverter efficiency 96.3% Static MPPT efficiency(weighted,reference EN50530) 99.6% Dynamic MPPT efficiency(fast irradiation changes,reference EN50530) 99.3% Night time power consumption 46mW Data Ambient temperature range -40'C to+65°C Operating temperature range(internal) -40'C to+85*C Dimensions(WxHxD) 17.3 cm x 16.4 cm x 2.5 cm(6.8"x 6.45"x 1.0")* Weight 1.6 kg(3.5 lbs) Cooling Natural convection-No fans Enclosure environmental rating Outdoor-NEMA 6 *without mounting bracket Features Compatibility Pairs with most 60-cell PV modules Communication Power line Warranty 25-year limited warranty Monitoring Free lifetime monitoring via Enlighten software Compliance UL1741/IEEE1547, FCC Part 15 Class B CAN/CSA-C22.2 NO.0-M91,0.4-04,and 107.1-01 Enphase Energy, Inc. 1420 N. McDowell Boulevard Petaluma,CA 94954 P:877-797-4743 infoCenphaseenergy.com 142-00010,Rev 04b http://www.enphase.com ©2012 Enphase Energy.All rights reserved. � w ENPHASE ENVOY COMMUNICATIONS GATEWAY CUP'ERTINO Building Department 'UN mji FOR CODE COMPLANCE i-�eviewed By The Enphase Microinverter continuously monitors itself and the performance of its associated PV module.This data is communicated over the existing power line to the Enphase Envoy communications gateway. Enphase Envoy may be plugged into any AC wall socket and connected using a standard ethernet cable to a broadband router, making it a true plug-and-play communications solution. Data collected by Enphase Envoy is then transmitted to the Enphase Enlighten website for monitoring and analysis. c® �S ENPHASE ENVOYTECHNICAL DATA Pow erline Enphase Proprietary LAN 10/100 Auto-sensing, Auto-negotiating Mill III! i; AC Outlet 120 Vac,60 Hz, 100mA Power Consumption 5 Watts i WIN, Dimensions(WxHxD) in Inches 8.8"x 4.4"x 1.7" Weight 12 oz(3408) 7 Ambient Temperature Range -40°C to+65°C(-400 to+149°F) Cooling Natural Convection-No Fans Enclosure Environmental Rating Indoor- NEMA 1 Standard Warranty Term 1 Year Compliance UL 60950, EN 60950 FCC Part 15 Class B Enphase Energy, Inc. 201 1 st Street,Suite 300,Petaluma,CA 94952 877 797 4743 enphaseenergycom ® Printed on loo percent recycled paper.