07040228 Plans r 5 _ Fw-IC A PEDLEY " ARCHITECT HITEC T INTERIORS * PLANNING 1793 Lafayette Street., Ste. 240 Santa Clara, Ca 95050 TeL 408.24-4.5200 Fax:408.244.5240 Ca. Lic.No.C-14419 esu PROJECT NAME: NEW UPS FOR imoi Arcsight, Inc. 5 Results Way A55REV N07E5 CF2� KI I1;� IREC70RNrCupertino, Ca �1u 1�3�7T 1;� CLIENT. ACOUS. ACOUSTICAL FURR. FURRING CLIENT: 1. CONTRACTOR SHALL PROVIDE ALL WORK AND MATERIALS IN ACCORDANCE WITH ALL LOCAL, STATE, �''"� ESCR11=710N ADJ. ADJUSTABLE 6At• 6A�U6E ELEVATION REFERENCE SY © � ND FEDERAL CODES, V.A.F.F. ABOVE FINISHED 6YP. GYPSUM L 11 [ ht, Inc11\✓ 2. CONTRACTOR SHALL FIELD INSPECT JOB SITE PRIOR TO COMMENCEMENT OF WORK AND SHALL ,�,r 1 Inc. FLOOR HDWR. HARDAA OOI ROOM NUMBER ADHERE TO ALL RULES GOVERNING CONSTRUCTION, SAFETY, BUILDING ACCESS, AND THE USE OF THE RESULTS MY FACILITIES AS SET BY THE BUILDING OWNER, BUILDING DEPARTMENT, FIRE DEPARTMENT AND STATE APPROX. APPROXIMATELY HT. HEIGHT AL G RTINO, G,4 AUTHORITIES. .,)j�, BD. BOARD H.M. HOLLOA METAL 3. IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR SHALL A-Q TITLE 5H T Results ay �{ ARCHITECT: .BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY BLK6. BLOCKING INT. INTERIOR BUILDIN6 SECTION SYMBOL p OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL up .sirtin BLD6e BUILDING JAN. JANITOR I H r L CT APPLY CONTINUOUSLY AND NOT BE LIMITED TO WORKING HOURS CAB, GA3INET MAX. MAXIMUM 4. ANY MECHANICAL, ELECTRICAL, LIGHTING, PLUMBING, STRUCTURAL, AND FIRE PROTECTION 3600 NERI06E AVE., SUITE 510 ENGINEERING DESIGNATED TO BE "DESIGN.BUILD BY OTHERS" ARE THOSE RESPONSIBLE FOR GL6• CEILING MFR. MANUFACTURER DOOR SYMBOL ENGINEERING, PERMITS, FEES, CALCULATIONS, REPORTS, DRAWINGS. ETC. REQUIRED BY LOCAL AND GLR. CLEAR MIN. MINIMUM DOOR SANTA GLARA, GA g505I ALL OTHER GOVERNING AGENCIES. ARCHITECTURAL ?/`J� •�* /� � [�? CONTRACTOR: COI.. COLUMN MISC. MISCELLANEOUS HARDAARE TEL: (406) 244e5200 5. CONTRACTOR SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES ENCOUNTERED ON THE DRAWINGS. ►"'t��./1-T f 1 4/T�/I'4aAL GONG. CONCRETE MOUNTED DOOR FAX: (405) 244.5200 SUCH TDISCREPANCIESED SHALL BE RESOLVED TO THE SATISFACTION OF THE ARCHITECT PRIOR TO CONT. CONTINUOUS N.I.G. NOT IN CONTRACT DETAIL SYMBOL *}� 6e CONTRACTOR 1S RESPONSIBLE FOR COORDINATING ALL SUB--CONTRACTORS TO INSURE A TIMELY A f. SITE ���CORR. CORRIDOR NO. OR # NUMBER 1 IN6 NUMBER COMPLETION OF THE JOB. NO ALLOWANCE SHALL BE MADE FOR INCREASED COSTS INCURRED DUE TO - GT1R. CENTER N.T.S. NOT TO SALE GENERAL. CONTRACTOR: LACK of PROPER CO-ORDINATION. 0. DEPTH O.G. ON CENTER 1 SHEET NUMBER 7. THE SUBCONTRACTORS SHALL REMOVE ALL RUBBISH AND WASTE MATERIALS ON A REGULAR BASIS .� �6 f Tf LKAi�I D.F. DRINKIN6 FOUNTAIN R. IU5 I-- om eric l udders AND SHALL EXERCISE STRICT CONTROL OVER JOB GLEANING TO PREVENT ANY QIRT, DEBRIEF OR DUST FROM AFFECTING IN ANY WAY FINISHED AREAS IN OR OUTSIDE JOB SITE. THE BUILDING REFUSE PET. DETAIL REQ`De REQUIRED FACILITIES SHALL NOT BE USED FOR THIS PURPOSE. 445 Leigh Ave, Suite TOO 8. GENERAL AND SUB-CONTRACTORS ARE RESPONSIBLE FOR INSPECTING THE PREMISES DURING , CJ11�11� r1G1 Builders DIAL. DIAMETER R.M. ROOM BIDDING To ASCERTAIN EXISTING CONDITIONS WHICH MIGHT AFFECT THE COST OR SCHEDULE OF DIM. DIMENSION SPEC. SPECIFICATION IA I ELEVATION SYM50L Los 6GIt45, GA g5032 CONSTRUCTION. DISCREPANCIES AND/OR CONFLICTS SHALL BE REPORTED TO THE ARCHITECT AND 445 Leigh Ave, Suite 100 DN. DOAN STD. STANDARD Ph:408-511-4000 Y TENANT BEFORE BID DATE. S DWG. DRAWING STOR. ST E 9. CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING LOCA EXCAVATION AND/OR DEMOLITION. TION OF ALL UTILITIES PRIOR TO Los Gatos, A 95032 (E} OR EX. EXISTING SUSP. SUSPENDED Fax:40a-5'11-A*O4 10. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO PROPERTY OR CONSTRUCTION Ph:408-37 7 -4800 EAT. EACH TEL. TELEPHONE NORTH ARROA MECHANICAL CONTRACTOR: RESULTING FROM WORK OF CONTRACTOR AND/OR SUB-CONTRACTORS, AND SHALL REPAIR ALL SUCH MECHANICAL APPROVED EQ. EQUAL TYP. TYPICAL DAMAGE TO ORIGINAL CONDITION AT NO ADDITIONAL COST, I O WTH THE I � FaX:408 377-4804 EXT. EXTERIOR U.O.N. UNLESS 11. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR EXECUTION OF WORK IN ACCORDANCE WITH I CODES AND INANCES F.D. FLOOR DRAIN OTHERWISE A ,,,, AIR CONSTRUCTION DOCUMENTS. BIDDING ON DOCUMENTS IS CONSIDERED ACCEPTANCE OF ALL NOTES C SHEET NAME: AND INFORMATION HEREIN. .- �' `�` �ea F.E,G• FIRE EXTIN6UI5HER NOTED f. 1A1�f CAS.` DATI ,r-- I15I S. TENTH 12. THE CONSTRUCTION DOCUMENTS ARE PROVIDE TO ILLUSTRATE THE DESIGN AND GENERAL TYPE of CABINET VIE. VERIFY IN FIELD CONSTRUCTION DESIRED AND To IMPLY THE FINEST QUALITY of CONSTRUCTION > MATERIAL, AND ,-2.• tv4 `� L M WORKMANSHIP THROUGHOUT. THE GENERAL CONTRACTOR, IN ASSUMING RESPONSIBILITY FOR THE I ° SAN JOSE, CA , FLOUR. FLUORESCENT A. AIDTH _. WORK INDICTED, SHALL COMPLY WITH THE SPIRIT AS WELL AS THE LETTER IN WHICH THEY WERE / r F� t= £ I #;, f1 i 0 F.O.F. FACE OF FINISH A•6. WIRE GLASS Ph:406-2D5-2300 WRITTEN. c't 11 � � FT. FOOT A.N. AATER HEATER 13. THE GENERAL CONTRACTOR SHALL MAINTAIN A CURRENT AND COMPLETE SET OF CONSTRUCTION , g, : �a SHEET DOCUMENTS ON THE JOB SITE DURING ALL PHASES OF CONSTRUCTION FOR USE OF ALL TRADES, AND ELECTRICAL ;, n SHALL PROVIDE ALL SUBCONTRACTORS WITH CURRENT CONSTRUCTION AS REQUIRED. xie ELECTRICAL CONTRACTOR: i�=�' 14. MATERIALS ARE SPECIFIED BY THEIR BRAND NAME TO ESTABLISH STANDARDS OF QUALITY AND PERFORMANCE. ANY REQUEST FOR SUBSTITUTION SHALL BE SUBMITTED TO THE ARCHITECT/ h�{{ !<' I I ' REDWOOD � ELECTRIC DESIGNER FOR REVIEW FOR EQUAL QUALITY AND PERFORMANCE AND SHALL NOT BE PURCHASED OR ELECTRICAL LAIN Al CRYINSTALLED WITHOUT THEIR WRITTEN APPROVAL. I650 ZANKER RP. 15. ALL WORK LISTED, SHOWN, OR IMPLIED ON ANY CONSTRUCTION DOCUMENTS SHALL BE SUPPLIED AND INSTALLED BY GENERAL CONTRACTOR, EXCEPT WHERE NOTED OTHERWISE. THE GENERALCONTRACTOR SHALL CLOSELY COORDINATE HIS WORK WITH THAT OF OTHER CONTRACTORS SAN JOSE, GA OR VENDORS TO ASSURE THAT ALL SCHEDULES ARE MET AND THAT ALL WORK IS DONE IN AI CONFORMANCE WITH MANUFACTURER'S REQUIREMENTS. Ph:406-453-0600 16. THE GENERAL CONTRACTOR SHALL SUBMIT SHOP DRAWINGS AS REQUESTED FOR FABRICATED ITEMS, CUTS OF ALL FIXTURES AND EQUIPMENT, AND SAMPLES OF ALL FINISHES CALLED FOR TO THE ARCHITECT / DESIGNER FOR APPROVAL PRIOR TO INSTALLATION, 17. CONTRACTOR SHALL CONFINE OPERATIONS TO AREAS PERMITTED BY LAW, ORDINANCES, PERMITS, AND THE CONTRACT DOCUMENTS, AND SHALL NOT UNREASONABLY ENCUMBER THE SITE WITH ANY MATERIAL OR EQUIPMENT. � 'L-_0001A7A I 1& ALL MATERIAL STORED ON THE SITE SHALL BE PROPERLY STACKED AND PROTECTED TO PREVENT I 7*4r tsolAroo X It DAMAGE AND/OR DETERIORATION UNTIL USE, FAILURE TO PROTECT MATERIALS MAY BE CAUSE FOR AIL MAMM AND YRTTEN MAID ULS APPEWN0 HEWN KTR REJECTION OF WORK. 19. CONTRACTOR SHALL BE RESPONSIBLE FOR CLEANING THE JOB SITE AT THE COMPLETION OF THE CONS7tTUSES D�C31NAd AND uNPUBuiED c OF ror+E WORK. CLEANING SHALL INCLUDE WINDOWS, FLOORING/CARPET, CABINETRY, WALLS, AND CEILINGS. Ai2CblITECT AND MAY NOT BE DUPLICATED,USED OR 20. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL DEBRIS FROM THE PREMISES. CHSCLOSED iMTNOUT aaaITTEN CONSENT OF THE AscauTEcr.. 21. ALL JOINTS, PENETRATIONS, AND OTHER OPENINGS IN THE BUILDING ENVELOPE SHALL BE SEALED, STREET ADDRESS: BUILDING CODES 2001 CW I14107 UBC CAULKED, GASKETED, OR WEATHER STRIPPED TO LIMIT AIR LEAKAGE REVISIONS: DATE RJP 5 RESULTS WAY "'OOO UMG r 22e ALL PATCHING, REPAIRING AND REPLACING OF MATERIALS AND SURFACES CUT OR DAMAGED IN PLAN CHECK 04/09/07 RJP .max w: EXECUTION OF WORK SHALL BE DONE WITH APPLICABLE MATERIALS SO THAT SURFACES REPLACEQ CUPERTINC3, CA 2000 UPG �4 'WILL, UPON COMPLETION, MATCH SURROUNDING SIMILAR SURFACES. Igga NEC, #01 04/17/07 RJP CITY COMM 06/11/07 RJP " m bC= 23. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL -'> KNOWLEDGE OR EFFORT. 1997 UBC• EFFORT TO OPERATE: EXTERIOR 5 Ibs., INTERIOR 5 Ibs., FIRE RATED $ tbs. 1997 UBC - 2001 CALIFORNIA. . 0FF1CwEV% _ 24. THRESHOLDS SHALL NOT HAVE A RISE GREATER THAN 1/2", 1997 UBC/2001CBC, , . BUILDING N 25. EXIT DOORS SHALL BE SO MARKED THAT THEY ARE READILY DISTINGUISHABLE FROM THE ADJACENT I I I- CONSTRUCTION. 1997 UBC/2001 CBC STAMP(S): W 26. EXIT DOORS SHALL BE ILLUMINATED AT FLOOR LEVEL WITH A MINIMUM OF 1 FOOTCANDLE AT TIME OCCUPANCY B 1 IIAI///{i jz 1 CIF OCCUPANCY. 1997 UBC/2001CBC 1 s fi. ri Al THE MAIN EXIT DOOR MOUNTED ON HORIZONTAL MULLION, TO READ THIS ,4 �'....a, '�'..a ,�,vtiSxi, `.+.. • " ...ra .: >, . . ......:# ., ,. : u ,, . :,._. iI�,;. . .. PROVIDE A SIGN ABOVE .., �; �� �� :.... �. �.�., ,,, � ,� ... t4u�. _:`;; : DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS , IN COMPLIANCE WITH 2O00 UBC. ,,�.,..t :Q' . -•'��: . Y :r TITLE 24. NUMBER OF STORKS 2 - NO C14419 .. 41 28. "ALL DOORS SHALL BE PROVIDED WITH LEVER TYPE HARDWARE IN COMPLIANCE WITH (For HD01&2) BUILDING AREA (//I5t FLOOR) 31 00.00 Sr- ` (�/�y� . �.- j Iw k ,, DOORS SHALL HAVE 10 S OF A SMOOTH UNINTERRUPTED r ..¢„�.'." ; sY;"' ...... ..4` w ,7t..:.. ,......5'n,:' ..� •ev -a',,:.NF*x.arm+"\ r c <, 2000 UBG CALIFORNIA 2001. ENTRANCE M � M ;;� .. , k ra ��_ ter. .. P INSTALLED TO EXISTING DOOR BOTTOMS T "lS0e00 Sr .ate { A`REA� OF GONE SURFACE AT THE BOTTOM OR HAVE A 1 D HIGH SMOOTH PANEL G - '•1 ,. (WHICH ARE NOT IN COMPLIANCE) 1997 E1BG.- CALIFORNIA 2001. ���r> � _ A BUILDINGACCESSIBILITYSYMBOL ON ADJACENT TO PRIMARY ENTRANCE DOORS VISIBLE TO II xr,, 29. PROVIDE BLI LDIN �x> r��,,� h :. I� �,;gg_;.' � ..�4���� „,S���Y {s��`��� t��, � .� b; �'• APPROACHING PEDESTRIANS, 1997 UBG.e ,.�,:. "`.'. ( ...,.,„. a.', :�5 ., t-'; �..�::. )� my; ��.,,aS`�,�k� J•`�Sti e�`��a� t� .�.� � .$f £s 'x,F..;. 30. FUTURE SlGNAGE SHALL BE DESIGNATED TO COMPLEMENT THE BUILDING AND SHALL BE SUBJECT TO e ` #,4' SCOPE OF THE WORK: TENANT IMPROVEMENT: r '' CITY APPROVAL �j RJP DRAWN BY: 31. PROVIDE A MINIMUM OF ONE CLASS 2-A: 10-B:C PORTABLE FIRE EXTINGUISHER FOR EVERY 3,000 S.F. INSTALL NEW UPS SYSTEM, OF FLOOR AREA AND PLACED SO THAT THE TRAVEL DISTANCE TO A FIRE EXTINGUISHER DOES NOT +° ): '":$ ..;a� 3a` *z -Y .' Z a"a r•'<et^' ,r :.,• YrIk IT is ,t�. ® $ { � EXCEED 75 FT, MODIFY MECHANICAL AND ELECTRICAL 32e WALL OUTLETS, LIGHT, WINDOW AND TEMPERATURE CONTROLS: DATE: 04/0 /07 A} CONTROLS TO BE AT 48" MAXIMUM, �` ::''s�`�'g�.;'.',i '{:{ da 36" ; ..... . z, �a x Y MINIMUM HEIGHT ABOVE FLOOR. WALL OUTLETS TO BE AT MINIMUM 12" ,� z : HEIGHT ABOVE FLOOR. 9 ® :W g ww PROJECT: 2726aresi ht I SPECASTM . TT-S-D023D TYPE II GLASS A 33. SEALANT SHALL COMPLY WITH FEDERAL ALL EXTERIOR . ry I <'S.., ;M,z.. ,71 .AP :�-."'�, 34. IN SEALANT SHALL COMPLY WITH FEDERAL SPEC. TT S 001657 TYPE I. Na z, I u ALL FEDE T .. ,per �. .� t <. ft .:e:+. ..:.. a 6...:...... ... .:... ... ..�:.'_N'... '..: ...x`*c..o-.±i+w>+,.w.Ka..z..... .t,s. "'"' 2 .. , . _u.. _. ... TO B USED. DO NOT SCALE THE DRAWINGS. ., .,>�,,.. 35. DIMENSIONS AS INDICATED ARE THE DIMENSIONS E 1" 1 Of 4 ., d. , RECOMMEND COMPLIES a .a, .. . i I. N,. . .. 1 EXCEPT AS SHOWN NEW VAN PARKING SPACE EXIST H.C. ACCESSIBLE 36. is T' .r 5'4 s. ^' : :. C �. Mom.. '" ,:r 'WITH 2O01 CB ,.. x h 0-,i':. SHEET O a. 14, od ° I�tx ,> :.. .;.::.. � to h .wiry n N E IPS SYS FEM FOR LON 4 ,U__ a s 's`:�' z :3d' ). Y°: ",Y° a 5 f''" e ur' ciX#c. ,;Y y `w,,.ri.,'r~:;,. i, ff . ,w e s tA) SYMBOL PROPO N 014 t� AL ai U. RICHARD t'B,� DISPLAY CONDITIONS NOTE: J� I'. ' THE SURFACE OF EACH ACCE551BLE PARKING SPACE OR STALL SHALL HAVE A SURFACE IDENTIFICATION DUPLICATING EITHER OF THE FOLLOWING SCHEMES: ARCHITECT 1. "BY OUTLINING OR PAINTING THE STALL OR SPACE IN BLUE AND OUTL 1 N I NG ON THE GROUND IN THE STALL OR SPACE IN WHITE OR SUITABLE CONTRASTING COLOR A PROFILE VIEYV DEPICTING A WHEELCHAIR W1TH OCCUPANT; OR INTERIORS * PLANNING 2. "BY OUTLINING A PROFILE VIEW OF A WHEELCHAIR WITH OCCUPANT IN WHITE ON BLUE BACKGROUND . . . AND SHALL BE 56 INCHES HIGH BY 56 INCHES WIDE, w V nu S R Q P ® N M 1793 Lafayette Street., Ste. 240 ' ''+ '' ^► Santa Clara, Ca 95050 H 1 V !.l � t✓fM'1 i (�I�ING�P�VME L,. 1 V T � ! V � � [ � � } � � ` Tel:408.244.5200 Fax:408.2�#4.5240 SCALE• E, Ca. I..ic. No. C-14419 } PROJECT NAME. 12"x IS"x VVa" REFLECTORIZED (--516N W/ THE "INTERNATIONAL 9 --- --- 6 NEW UPS FOR SYMBOL OF ACCE551BILITY11 AND LETTERING, IN WHITE ON t -y ArcSight, Inc. DARK BACKGROUND, SILK— SCREENED ON ALUMINUM OR BOTTOM OF 516N Par ing my GALVANIZED METAL PER THE ..._, BOTTOM OF SIGN ssible, CURRENT EDITIONS OF THE Rt: l`" ItS '+ G.B.G. AND A.D.A.G. 10 -- Cupertino, Ca CLIENT: z VAN-ACGE551BILITY SIGN, WHERE �� t APPLICABLE n \ ArcSl ht, Inc. Results Wa Y FHI&HEST AA.�CENT °°� GALVANIZED STEEL POST -, �! Cupertino, a FINISHED 65PRAVE l _---- --LOAEST POINT CONTRACTOR: OF ADJACENT — 12"� CONCRETE BASE O 0 FINISHED e GRADE a a 13 O 0 NOTE: WHERE A WALL OCCURS AT THE WALKWAY END OF THE PARKING SPACE, 51 GN MAY BE CENTERED ON THE YVAL.L AT A MINIMUM HEIGHT OF 5'-0" FROM THE PARKING, SPACE FINISH GRADE, GROUNP OR 51DEWALK (WHICHEVER 15 HIGHE5T) INSTEAD OF ON POST. HANDICAP PARKINS SPACE SIG Commerical Builders _ � SCALE: NONE 445 Leigh Ave, Suite 100 Los Gatos, CA 95032 7O 50. INC ACCESSIBILITY SIGN � `# Ph:408-377-4800 PER SEC. 1I2415.5 Fax:408-377-4804 A SHEET NAME: `T WITHIN ACCESSIBLE PARKING STALL PAINT THE WORD5 "NO PARKING" �� ---- PLAN IN 12" H. LETTERS, MIN. .. arosre e®tw T11 CONCRETE NOTE: RAMPS SHALL NOT 1NHEELSTOP ENCROACH INTO ANY ACCE551BLE PARKING 5PjkCr= OR THE ADJACENT ACCE AISLE PER C.B.C. SECTION 1124IB.S.5. PAINT FIGURE FERENCE SITE PLAN ' WHITE ON BLUE -E BACKGROUND ____ I-oil 3 _ TYP. A_01 , _ tr.er erut� sort PATH OF TRAVEL- TO THE All DRAWINGS AND WrEN MAIWAtS APPEARING HBWN BLDG ENTRANCE AND TO CONS UMS ANAL AND U14PUt SHM of 1HE q'-0" MIN. z THE HANDICAP RESTROOMS FLAT LOADING 5—O MIN. AT TYP. `_ "• MIN, , ARe fticT AND MAY NOT etr DUPUGATED,USED OR ACCESSIBLE PARKING STALL ` TYP V47N«'T WR WOONSENT OF 1NE ARCHITECT. CT. ZONE, 4"W 45i' WHITE &-0" MIN. AT VAN 5TRIPING @ 3 —O O.G. N ACCESOLE PARKING STALL «a WALKWAYS AND SIDEWALKS ALONG REVISIONS: DATE RJP A-01 ACCESSIBLE ROUTES OF TRAVEL PLAN CHECK °a/oB/o7 RJP ;Z HANDICAP PARKING EXIST. RAMPS DO NOT 'NO PARKING' PAINTED }N (1) ARE CONTINUOUSLY ACCESSIBLE, 1 /17/ 7 RJP SCALE: NONE ENCROACH INTO ACCESS » " CITY COMM 06/11/07 RJP AISLES ACCESS AISLE, 12 H. LETTERS, (2) HAVE MAXIMUM 1/2 CHANGE IN 70 50. INCH WHITE PAINT (TYP.) ELEVATION, ACCESSIBILITY 516N VAN ACCESSIBLE (3) ARE MINIMUM 48" IN WIDTH, AND PER SEC. 112415.5 SPACE (4) WHERE NECESSARY TO .CHANGE ELEVATION AT A SLOPE EXCEEDING STAMP(s): 3 5% (1.E., 1: 20) SHALL HAVE RAMPS COMPLYING WITH UBC 11338.5 e -- WITHIN ACCESSIBLE tn NO.0 14419 _ PAINT L. V1 u as EXP. 2/28/0 PARKING STAL THE WORDS NO PARKING IN 12" H. LETTERS, MIN. CONCRETE NOTE: RAMPS SHALL NOT WHEELSTOP ENCROACH INTO ANY ACCE551BLE PARKING SP OR THE ADJACENT ACCES DRAWN BY: ' A15LE PER 0.5.C. SECTION 112gB.5.5. DATE: 04/05/07 h PROJECT: 2726aresight o F I II q`-O°' MIN. 5'-0" MIN, AT TYP. a_ ... FLAT LOADING ACCE551BLE PARKINC•� STALL -LIM 11 ISM ARE N E ZONE; 4"W 45 AHITE SI_O" MIN, AT VAN SHEET STRIPING 3-0 O.C. AGGESOLE PARKING STALL A-1.0 aa� � ACCESSIBLE STALL �" SCALE: NONE rr rr CONF. ROOM OFFICE OFFICE OFFICE OFFICE ORRICE OFFICE OFFICE OR E OFFICE OFFICE »� 01 �.9O 172.1® SF 158.45 Sr 145.6a SF rl 45.90 SF 145.40 SF L210.80 SF 1210.60 SF I F1148.80 SF I147.4a SF " s trr 22 QCC. 2 2 QCC. 1 QCC. 1 QCC. 1 QCC. 2 QCC 2 QCC. 1 QCC. 1 QCC> 1 QCC. 2lb9l.,30 SF 2 2 1 1 1 1 1 1 2 ...... .... ..� 2 ____ 1 1 1 3 "1 6 QCC. 22 RICHARD Copy OPEN OFFICE C?U t�UIET' QUIET , 124�OS �� PEDLE 1 0 Oil � ----- ,► 3 ` , ARCHITECT ENS ECH. a LOBBY -'' STOR. OFFICE � INTERIORS * PLANNING '..°. ". ."� ONF. R 1148.80 SF . ;` ` 1793 Lafayette Street. Ste. 240 1 QCC. AN. i � T 1 f „° � � 162.3a SF � 0) Santa Clara, Ca 95450 a 6 I i A 1 R�CE N 11 QCC. Tel:408.244.5200 Fax:408.244.5240 OFFICE SER R R M i j � ► 1 23 �`� `� ca. Lic. No. c-14419 7SF 15a.40 MEWS 1581.80 SF 1 1 I I ` �` PROJECT NAME: 1 QCC. 1 6 QCC I I 1 ! WOMEN'SNEW UPS FOR 0 I 1 i IArcSi ht 9 Inc. OFFICE � � Li � � CONF. `` �` 1148.40 SF 1 4OFFICE 1344.26 SF 1 �\ �` Results Way 1 QCC. 1 22 368.6a SF ...... . 23 QCC. l ` Cupertino, Ca .. ' 4 QCC `� CLIENT: OFFICE t e MEWS 148.2a SF �I 0 ArcS_ight,. I . 1 QCC: CONK. R M .�.., ,�. ' \ i Qo C a 1 1325.46 , SF r______,______.� OPEN OFFICE ,- ------ r______,___ __ _ .-:-.---_.. Results Way 22 QCC. I I I I I ! ! I 1 ! JAN TELEPH E 112771.as SF � I ! i f 1 ! Cupertino, Ca OFFICE f i i f I I f 1 f COPY 0 . .._... , _.._ . .. _1```~1210.90 SF .... -�.. 128 QCC � _____ _____ _ _ __ - __ __ _____ __,_.._ - CONTRACTOR: _�_ -.� : • j-- _i� � ! I �f f 3 CONTRACT{?R: 2 QCC. II I I I __.-_ --�- ! OPEN OFFICE STORAGE r ._ ----- --------.I------ -- 1 ! I f f I______,.. --------______- OFFICE 1�90.80 SFf I ! 1 i I ! ! ! f I i i i I 1 I ! i i 1 i I f l 1 I Jr` 3 QCC . t 1201.80 SF 141 ! ! 1 ! i _ ____f__ __ _ _. ____1_ _ _ __ i I i 1 f f Comm.encal. Builders .2 QCC __ __ I L._ _j 1 �._.____ ._.I______i I I f I I L_ _____I_ ___�. 1 L.__ _._: _ __I._..__ ._.__� _.. i I 1 I f 1 f I f 1 I ! I I f I f 445 Leigh Ave, Sup to 100 f I f I 1 I I ! I ! I f 1 I 2 ! 1 I i i I I I f l l 1 _ 1_ ! i 1 I i I Los Gatos, CA. 95032 Ph:408-377-4800 ___..___.__-i L_______I_..____ _ _I L_____ L___ ____I_...._ __..___J I_..____._. .._._I__ _ ___J Fax:408-377-4804 CONF. RM c� TRAINING R AREA OF CONTRACT SHEET NAME: ® [!56.�60SF -- -I F _I_ --1 r _ _ __ _ . !_-____ F --1-- -- '° - � 1842.90 SF 10 QCC. _10 I ! � I I 1 ! 12 (N)UPS ! ! I I f f 56 QCC ! 1 I I I l I OFFICE 150KVA ! l I i f f 56 -- 18 .36 SF 181.36 SF ____ _1____ __ _ ____ __ VY PLAN ______ - I i f i I I f 2 QCC. 2 Q C. A 1 l 1 f ! 1 I I BREAK ROOM f 1 I 1 1 1 i I i 1 I l 1 1 I I I ! f ! I I I f 661.40 SF 2 --- I _ __ __ 1 ...__ _ 1 i _ _...._., - 44 QCC CO E RM. i 1 I i 1 I � ..... ,�. 1 f 1 1 I 1 T R. 174.6a SF I I 1 ! l I 1 f i f I f 1 I I i 1 1 CONF. RM �j I I 1 f 1 I 1 12 QCC. 12 ! I 1 ! I I I 164.1 a SF I 1 I I 1 I L_. I _ _ _ __I_ ____ _J � _ _ _ _ �______.. - E L- -----i--- - .J L---- --I--- ---_.I 1 11 QCC. 44 Uj ALL DRAWN"AND%WTIEN M TERiALS APPEARING HEREIN CONSTITUTES ORIGINAL AND UNPUNISHED WORK OF THE • ARCNI7ECT AND MAY NOT DUPLICATED, USED tlFd DISCLOSED MMOUT WRITTEN CONSENT OF THE ARCHITECT. REPLACE EXIST. 3'-O" DOOR WITH NEW 60 MIN. RATED ... REVISIONS: DATE RJP DOOR AND FRAME. PROVIDE HC LEVER LOCKSET, •. '• CLOSER, SMOKE SEALS AND DOOR STOP LAN PLAN CHECK 04/09/07 RJP SEE UPS CABINET CUT SHEETS FOR SECONDARY �ft� X I T I Pmm G/ rm L 0 0 R .� $t' ff=Q�r CONTAINMENT SPECIFICATIONS 2 LAYERS 518*'TYI°S`x` #01 04/17/07 RJP 6YP.W. Z 112"PLYYk= CITY COMM 06/11/07 RJP �----- DIRECTIONAL EXIT SIGN r^ 1 1 h1 �^1 LI. _ ___ __ _____ _ __ _ ___ �. __ EXIT SIGN OCCUPANT LOAD: "_ CC. STAMP(S): ���1�!l11111 I I I l t lli1�z PATH OF TRAVEL TO EXIT ° Q I 1 I EXIT WIDTH RECUT " ED 99 S,p.AC4. (NO. OF OCCUPANTS x .2 = 0 GRADE) � TILM cL6 1 1 I I EXIT OUTSIDE FROM BUILDING �X " ' 'I�"I'H PRO Y IDED� �4 EXP. 2/28/09 05/6 Type i I f f-g 6YF.IUD.ONStW i I sk SIDE of G 220&MET.$ BLOGKIN6 i I I ! q��. AT LEAST ONE FIRE EXTINGUISHER WITH A MIN.. RATING NOTE: ALL DOORS HAVE A MIN. 32" CLR, OPENING TO AS 1IRM. 1 ( } ! (Woo TYPE `V OF 2A:10B:C SHALL BE INSTALLED IN COMMERCIAL OR 6yr•Ev•ON INDUSTRIAL FACILITIES FOR EVERY 3,000 SF OF FLOOR ALLOW A MAX. OF 160 OCCUPANTS PER DOOR, SA.SIDS OF b" AREA OR 75 FEET OF TRAVEL. THE EXTINGUISHER SHALL DRAWN BY: ZO 6A I z. StUD5 BE MOUNTED TO A WALL SO THAT THE TOP DOES NOT 1 »a EXCEED FIVE (5) FEET ABOVE THE FINISHED FLOOR. 4 I 1 AS R A SIGN INDICATING THE LOCATION OF THE EXTINGUISHER MOTE: EXIT SIGNS SHALL BE INSTALLED AS REQUIRED DATE: 04/05/07 N I ! SHALL BE INSTALLED ABOVE THE EXTINGUISHER SO THAT TO COMPLY WITH SECTION 1003.2.8.2. 1 I THE LOCATION CAN BE IDENTIFIED. PROVIDE EXIT SIGNS IMMEDIATELY INSIDE ALL PUBLIC i f ENTRANCES. PROJECT: 2726oresight f ! i LINE OF PLK f f LINS OF M _ - SHEET ` fjJjj S I - i !j'fx��� - ALL ( I I f4FJJJ oN A mm j CONSULTANTS: I 'qr jAtN61,q . i j THOMAS Aa JOHNSON & Associates Inc. CONSULTING ENGINEERS STRUCTURAL DESIGN THO AS A. JOrl, ISOS! TA THOMAS� A. JOHNS ON { I .. & Associates Inc. c Associates Inc. 2636 NO FIRST STREIEI' SUITE 210 CONSULTING ENGINEERS CONSULTING ENGINEERS �' �I.Ir=+ I STRUCTURAL DESIGN STRUCTURAL DESIGN C3otp Project Sht. No. °`` Date Project Sht. No, m i P PROJECTI�a�n NEW UPS Fum ` ` ► . biro. t 1 — tt - ArcS In ,Tf . 'GRKI�i y tL �lgllt, I )`/ - •: S d - I �. , C _ rt 'P Cf1149 uperfino, I;t La 4. t 5 i . I $' - ;# CAI EN T: t I A'lIx.il � , ¢ SCAt7' S <:,. ,. a `�"" .�� .• '� '^Y�.G.�'� � �G` � �. °. ,�' � *" -��,:+ .✓-e'er `� .?` _ c6'.�'�,:�,��" � �.N F,��=""'f`r ,&"�Y :� Y fw'������,.. may. �;,�,�.� .� �rr h a.a 4 l 1�4.f,CS ;,;upertino, Ca AT scftvA 114 L�o I {t,7}! 4 i CONTRACTOR: LL #:� t.."�.�"�`.��„���,,X41-`fit` j�l ��1 .�1`�L, � � .,{��5k'� �... , .,•, = I�I��.I-33:- '?.,.t�I� a .- . 2 " Ce 4"St' CttitA,. eR `4v`C Commerical Builders 44 Leigh Ave, Suite 100 Los O s 0503 hn 408 -3'' - 4800 -a ° 40 �-. 77._-�_ 04 T A. J � T S . J Ht S 1A. & Associates Inc. 8c Associates Inc. CONSULTING ENGINEERS CONSULTING ENGINEERS Spft T U(;ftTURAL STRUCTURAL DESIGN STRUCTURAL DESIGN SHEET NAME Date Project � l ;�'C Sht> No, Dote Project Sht. No UALL;U LAT I Ow" N%`56 FL PLAN SECTIONS U LTS WAS ,. GENERAL S No. 2 ' 18 R >5-31-09 CLIENT: 13 ri U6. i I✓ .iCA ' CALCULATION SECTION SHEET ALL DRA�WNGS AND WRITTEN MATERIALS APPEARING HEREIN ;gyp; CONSTITUTES ORIGINAL AND UNPUBLISHED WORK OF THE ENGINEER AND MAY NOT BE DUPLICATED, USED OR 0,6 i # DISCLOSED NJ}TH011T WRITTEN CONSENT CP TtiEENGdNEER. . a � REVISIONS: DATE 141 T O A A,.- J HNC & ASSOCIATES INC. � � � .�- y1r CONSULTING ENGINEERS STRUCTURAL. DESIGN 2635 No. First St., Suite 210 San Jose, CA 95134 (408) 943-9280 S `i - I t } } ._ . . DRAWN BY- DATE: DATE: 4-12-07 i PROJECT: TAJ 07015 - i "__7777t 7 3 SHEET o ( 1 t SPLIT SYSTEM INDOOR A/C UNIT SCHEDULE SUPPLY FAN CAPACITY(MBH) ELEC. DATA OPER, VIB. SYMBOL MAKE MODEL LOCATION WT, ISO, REMARKS CFM ESP{IN} TOTAL SENS, VOLT PH Hz RLA (LBS,) (IN) FC SANYO KH3672R OFFICE 830 0,25ii ---- 33,5 ---- -- 60 -- 75 WALL MOUNTED; PROVIDE W/ LINE SET & CONDENSATE PUMP 21 CALAIR, INC. NOTES; 1, UNIT POWER CONNECTION AT CONDENSING UNIT, 1555 SO. SEVENTH ST.,BLDG K, 2, ELECTRICAL CONTRACTOR TO PROVIDE SEPARATE 120V-10 POWER FOR CONDENSATE PUMP. SAN JOSE, CA 95112 (408) 283-2300, FAX (408) 293-9511 AIR COOLED CONDENSING UNIT SCHEDULE d The infomation,deVaons and detalls in this document are protected CAPACITY (MBH) ELEC. DATA OPER. VIB, W T ISO. REMARK by — ap INC. le copyright protections and are the exclusive pr h of Cld-NR, INC. My unauthorized u�or dupCcotian is strictly prafiibited and is violation of all app te" copyright protection laws and CAI.—Alles SYMBOL MAKE MODEL rights. Any submission or other tmnsnission by CAL—AIR is not TOTAL SENS, VOLT PH Hz {LBS,y {IN} proprietary 47 to be deemed a waver of CAL—AiR s rights and all such eights are by CJU-AIR. CU SANYO C3672R ---- 33.5 208/ 1 60 19,4 150 -- SLEEPER MOUNTED; PROVIDE LOW-AMBIENT CONTROLS , 230 ����p CONT�,�c� AIR EXHAUST FAN SCHEDULE. N . 1 � EXP.11l8Ql240 PAN MOTOR OPER, VIB. s� c-4c--�� SYMBOL MAKE MODEL LOCATION SERVICES CFM TSP TYPE WT, ISO, REMARKS °F (IN) CONSTRUCTION ELEC. DATA AMPS RPM {LBS,} (IN) EF ATTIC MOUNTED, PROVIDE BACKDRAFT DAMPER; 24/i OPERATION, INTERLOCK WITH LOCAL ALARM AND 1 GREENHECK CSP-A410 ATTIC ROOM 121 217 0,5 INLINE STANDARD 1,87 1000 120 1 60 36 - UPS. UPON FAILURE OF FAN, ALARM SHALL INTIATE AND UPS CHARGING SYSTEM SHALL DISENGAGE. GENERAL NOTES: 1. ALL EQUIPMENT MUST BE LISTED BY AN APPROVED TESTING AGENCY AND INSTALLED IN ACCORDANCE WITH ITS INSTRUCTIONS AND LISTING, 2, MATERIALS FOR METAL DUCTS SHALL COMPLY WITH CMC SECTION 602.5 2C>$1230 V, 1 EQUIPEMENT ATTCHED 3. METAL DUCTS WILL BE SUPPORTED PER THE MINIMUM E TO SLEEPER REQUIREMENT OF CMC TABLE 6-5 AND DUCT SHALL BE M ICU INSTALLED WITH SEISMIC RESTRAINT PER SMACNA. 4, ALL FACTORY MADE AIR DUCT, IF USED, WILL BE CLASS DISCONNECT 1 OR 0 LISTED DUCTS. n (TYP.) a Q EXISTING ROOF 5. THE FACTORY MADE AIR DUCTS WILL BE SUPPORTED PER SCREEN SLEEPER THE MINIMUM REQUIREMENT OF CMC TABLE 6-6 OR PER MANUFACTURER'S APPROVED SPACING WHICH EVER IS FARTHER APART, PROGRAMMABLE STAT FAN COIL CONDENSING UNIT Z 6, APPROVED LINING MATERIALS , INSTALLED WITHIN DUCTS AND PLENUMS SHALL HAVE A MOLD, HUMIDITY AND E INTERCONNECTING ERROSION RESISTANT SURFACE THAT MEETS THE POWER WIRING REQUIREMENTS OF CMC CHAPTER 16, PART II. 7. A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND ELECTRICAL CONTRACTOR To PROVIDE SMOKE DEVELOPMENT RATING OF NOT MORE THAN 50 SEPARATE 120V-10 FOR CONDENSATE PUMP. ROOF FOR MATERIALS EXPOSED WITHIN THE DUCTS OR PLENUMS. z 8. INSULATION MATERIALS APPLIED TO THE EXTERIOR OF ri`� CONDENSING UNIT MOUNTING , DETAIL DUCTS, LOCATED IN THE BUILDING, ARE TO HAVE A (`_1 DUCTLESS SPLIT SYSTEM UNITCONTROL FLAME SPREAD OF NOT MORE THAN 25 AND v tu -- ' cU/Fc-1 M -- ' cu-1 _ NTH NTs - SMOKE-DEVELOPMENT RATING NOT EXCEEDING 50 WHEN n W TESTED AS A COMPOSITE INSTALLATION. (D ttu -7 `� r..* •r #f ' S .G_ 9. FIRE AND SMOKE DAMPERS SHALL BE LABELED BY AN z .y ` APPROVED AGENCY. U Q //�� 77- 7 10. FIRE AND SMOKE DAMPERS TO BE UL LISTING: UL555 1 w © o �� �� �` AND CALIFORNIA STATE FIRE MASHALL LISTING o N #:3225-245:00. c� r � 11, INSTALLATION . MANUALS FOR ALL LISTED EQUIPMENT z AND FIRE AND SMOKE DAMPERS SHALL BE AVAILABLE IF Revisions . REQUESTED BY THE CITY INSPECTOR AT THE SITE, Project 12, ALL PIPING TO BE COPPER TYPES ACR & L OR SCH. 10 ° BLACK STEEL U.N.O. PIPING MATERIALS TO COMPLY WITH U.M.C. AND BE INSULATED PER TITLE 24. o - ARCSIGHT hu Oleh` 5 RESULTS WY. w cn � .. z. . ER CA a LLJ , Title �i _ k i MECHANICAL co p SCHEDULES 3 AND DETAILS 2005 TITLE 24 SYSTEM NO. DUCTWORK LEAKAGE TEST N/A Project Manager Project Engineer a r R DUCT INSULATION R - 4.2 R - 8.0 ®AB RSG 4 .. ,. Drawn By Date ,Ied DISTRIBUTION DUCTWORK N/A N/A RS£� 4/0/ 7 ROOF DUCT N/A N/A .: Job Number Scale° a } APPROVED FOR CONSTRUCTION o t a SIGNATURE DATE ` DRAFTSMAN: Dwg. Number `° ENGINEER: v J < �, .� ! ! I ! "A CAL-AI INC. I I ! I I l ! I ! 1555 SO. SEVENTH ST.,BLDG K, ! SAN JOSE, CA 95112 (408) 283-2300, FAX (408) 293-9511 (D The information, depictions and details in this document are protected by all applicable copyright protections and are the exclusive property of ! CAL—AIR, INC. Any unauthorized use or du0io tion is strictly prohibited and is violation of all applicable copyright protection laws and CAL—Ales proprietary rights. Any submi ion or other transmission by CAL—AIR is not OFFICE OFFICE OFFICE OFFICE OFFICE DOUBLE OFFICE DOUBLE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE to be deemed a wrdvcr of CAL-AiR's rigt>#s and all such ri4t.ta are 165 164 163 162 161 16O 124 125 126 127 128 Li Li129 reserved by CAI—AfR. PATIO IJ CONFERENCE I 1G6 �, �® CONT�, f _.._ W. SHOWER 158 15i 138 137 ,-AIR HALL 10G QUIET RM. 1 I 0 G 142 Rk RM. ELECT. RM EXECUTIVE ADMIN. OFFICE �.._.bP.1 0 136EMIEXP.��tsot2noa ') P r ID LOBBY ®o Ar �! �6 J Pt�. o° � •� �j 101 � �',�. � ` - COPY/FAX ELEV. EQUIP, EL R ❑ Ofi CAS-����� C > WOMEN'. O o 7 156 rE STAIR OD NO. 3 T o S ORAGE OFFICEqL 145 OFFICE O WH 168 WAN _ H I �EPTION WRAP WALLS Wj I I , CONFERENCE '._ . 3a4' RATED SERVER RO 110 PLYWOOD BACBOARD OFFICE (PAINT TO MATCH) 123 144 MEN'So 3 V41 0 o o E -.` 134 ° WOMEN'S o COFFEE a EK O 102 W. SHOWER � � � a o 105 F E O OFFICE 09 n PS ° 146 ® POSSIBLE FUTURE POSSIBLE FUTURE INDOOR U-3 N IE) FAN-COIL WITH PU ED o SHOWER-] SEE ERS ON OOF CONDENSATE P.O.C. TO (E) DRAIN ON ROOF O o C(: ..��..� OPEN OFFICE o OFFICE `��. o M. SHOWER 133 CONFERENCE MEN 104 147 132 ° 103 U013roll CONFEREN - 167 -. . JAN. �° EPI WRAP TELCO RM. 139 DOUBLE OFFICE o 1�� FAX/COPY ° WALLS RWITH D WH PLYWOOD BACKBO D 112 111 PAINT TO MATCH 148 -� < Y Z O 0 DOUBLE OFFICE STORAGE Z 141 0 (E STAIR z 149 f T � 4 , , � I ILL— C '�J TRAINING ROOM A $ ( EF 2 113 1-18 217 l�- 1 _ _- --- �— ---A- 12"0 SPIRAL 10 90"� UTR TER INATE _ e �� �� �� � � �� z z CONFCE 0 8" SPIRAL �--71 �- WITH RAIN C P 10" d > > 1 i Fc — X � t t� _ _ 1 RAGE - — w ---�" llm l 2 --- o aG fir+ 7 t�-1 l COND. PIMP tt i tUu E) STAIR DOU � E (TYP.) o o Z = -Y4 CON ENSATE UP � � COFFEE U v 0. 1 a THRU ROOF; P.O.C. 113 STORAGE z z L_JE -� o — _— CU GU tC . DRAIN ON RO F 1 2 8"� L LOCAL ALARM � � ,' , 4 a.. tz. u I__ 1 n CD COFFEE IN ROOF) (ON RO � a o El `� 151 ® Cq V_ BREAK REA CONFERENCE BREA BAREA 4 o ® r. �_ 154 z ``� 116 , — I Revisions � � ( Project EXISTING PATIO ARCSIGHT LEGEND: co �+ - SUPPLY AIR DIFFUSER - SUPPLY AIR ROOF PENETRATION a 5 FU I VNY. z ++ - EXISTING SUPPLY AIR DIFFUSER - RETURN AIR ROOF PENETRATION CA THERMAFUSER - EXHAUST AIR 'ROOF PENETRATION ® - CURVE BLADE DIFFUSER - LINED DUCTWORK _ U.C. - UNDER-CUT DOOR Title r RETURN AIR GRILLE [71 - EXISTING RETURN AIR GRILLE F.D. - FIRE DAMPER ® _ MECHANICAL - EXHAUST GRILLE S.F.D. SMOKE FIRE DAMPER ---B.D.D. - BACKDRAFT DAMPER FLOOR PLAN 0 - SMOKE DETECTOR 200 TITLE 24 SYSTEM NO. - ROOM THERMOSTAT - POINT OF CONNECTION O - EXISTING ROOM THERMOSTAT Q----- - EXISTING DUCTWORK LEAKAGE TEST NIA Project Manager Project Engineer o @ - BY-PASS TIMER 8--- - Nam{ //��►� S�+ /�� r�ryry = nn DAB RSG f D�VT IN�7�LI"'1TI�N R 4.G R �.V ' XXX DIFFUSER AIR BALANCE READING Drawn By De Ta { - RELOCATE n DISTRIBUTION DUCTWORK NIA N/A - SQUARE TO ROUND FITTING ROOF' DUCT N/A N/A - - - - REMOVE t�SGfg107 Job Number Sc� e WYE BRANCH - FAN POWERED HEPA FILTER w r - VOLUME DAMPER APPROVED FOR CONSTRUCTION � o-ago �e� ! ,� yy - FLEXIBLE DUCT W/ VOLUME DAMPER - DUCTED HEPA FILTER In SIGNATURE DATE FLEXIBLE DUCT XXX - DIFFUSER AIR BALANCE READING Dwg. Number DRAFTSMAN: . - - SPIRAL DUCT ENGINEER: o ..� as CO MANDATORY MEASURES --- -_ _- _ , , CERTIFICATE OF COMPLIANCE (Part 1 of 3) MECH- I -C CERTIFICATE OF COMPLIANCE (Part 2 of 3) MECH•- 1 -C CERTIFICATE OF COMPLIANCE (Part 3 of 3)- MECH--1 -�C Eawpment and Systems Effldg"c PROJECT NAME DATE PROJECT NAME DATE PROJECT NAME DATE CALAIR INC. Any appliance for which there is a California standard established In the Appliance Efficiency Standards may be installed ARCSIGHT 7/9/06 ARCSIGHT 7/9/06 ARCSIGHT 7/9/06 only if the manufacturer has certified to the Commission, as specified in those regulations, that the appliance complies PROJECT ADDRESS with the applicable standard for that appliance. Included are room air conditioners, central air conditioning heat pumps 101 METRO DRIVE, SUITE 100, SAN JOSE CA Designer: (regardless of copicity, except that requirements for central air conditioning heat pumps with cooling capicity of g Test Description Test Performed 135,000 Btu/hr or more apply to heating performance but not to cooling performance), other central air conditioners PRINCIPAL DESIGNER—MECHANICAL TELEPHONE ildinQ Permit This form is to be used by the designer and attached to the plans. Listed below are all the acceptance tests far 1555 SO. SEVENTH ST.,BLDG K, with a cooling capicity less than 135,000 Btu/hr. fan. type central furnaces with Input rate less than 400,000 Btu/hr, CAL.-AIR INC. 408-283-2300 mechanical systems. The designer is required to check the boxes by all acceptance tests that apply and list all ✓D MECH-5-A: Air Distribution Acceptance Document boilers wall furnaces, floor furnaces, room heaters, unit heaters, and duct furnaces shall have been certified to the DOCUMENTATION AUTHOR TELEPHONE checked �y ate ui merit that re wires an aces lance test. !f a1! a ui merit of a certain type requires a test, list the equipment This test required if the unit serves 5,000 ft of space or less and 25% or more of the ducts SAN JOSE, CA 95112 California Energy Commission by its manufacturer to comply with the Appliance Efficiency Standards. Enforcement Agency Use P q P equipment ALEX POLISSKY 408-283-2300 description and the number of systems to be tested in parentheses. The NJ number designates the Section in the are in nonconditioned or semiconditioned space like an attic. systems that meet the The following space conditioning equipment may be installed only If the manufacturer has certified that the equipment above re ulrements. tams that meet the above re uirements and either extend (448} 2$3-2300, FAX (408) 293-9511 meets or exceeds oil applicable efficiency requirements listed In 112 of the Energy Efficiency Standards: all air GENERAL INFORMATION Appendix of the Nonresidential ACM Manual that describes the test,. Also indicate the person responsible for performing q q conditioners, heat pumps and condensing units > 135,000 Btu/hr; all water chillers; all gas-fired boilers > 300,000 DATE OF PLANS BUILDING CONDITIONED FLOOR AREA CLIMATE ZONE the tests {i.e. the installing contractor, design professional or an agent selected by the owner). Since this form will be ducts, replace ducts or replace the packaged unit. Btu/hr,, all oil fired boilers > 225,000 Btu/hr, and all worm air furnaces and combination worm air fumaces/air- part of the of this section will allow the responsible party to budget for the scope of work appropriately. conditioning units > 225,000 Btu/hr. Fan type central furnaces shall not have a pilot light. BUILDING TYPE ® NONRESIDENTIAL ❑ HIGH RISE RESIDENTIAL ❑ HOTEL/MOTEL GUEST e pans, comp Equipment requiring acceptance testing N/A Piping, except those conveying fluids at temperatures between 60T and 1057, or within HVAC equipment, shall be ROOM Q The infommtion,depictions and details in this document are protected Insulated In accordance with Standards #123. Building Departments: by all applicable copyright protections and are the exdusve property of Air handlingducts systems shall be constructed, installed, sealed and insulated as provided in Chapter 10 of the PHASE OF CONSTRUCTION ❑ NEW CONSTRUCTION ❑ ADDITION ALTERATION ❑UNCONDITIONED Systems Acceptance. Before occupancy permit is granted for a newly constructed building or space, or a new space- CAL-AIR, INC. unauthorized use or duplication is Ys P P �1Y Pt� strictly prohibited Uniform Mechanical Code. file affidavit conditioning system serving a building or space is operated for normal use, all control devices serving the building or �+ and La violation of all applicable copyright protection lass and CAI.-AIR s C®ntrols space shall be certified as meeting the Acceptance Requirements for Code Compliance.. PROOF OF ENVELOPE COMPLIANCE ❑ PREVIOUS ENVELOPE PERMIT ❑ENVELOPE COMPLIANCE ATTACHED ry rights. Any submission or other trensmissxui by CAL-AIR is not STATEMENT OF COMPLIANCE In addition a Certificate of Acceptance,.MECH-I-A, Form shall be submitted to the building department that certifies to be deemed a waiver of CAL-AIR's rights and all such rights are Each space conditioning system shall be Installed with an automatic time switch with an accesible manual overide that ✓® MECH-6-A: Demand Control Ventilation Acceptance Document C4Nrq expressly mr4ed by CAL-AIR. allows operation of the system during off-hours for u to 4 hours. The time switch shall be capable plans, specifications, installation certificates, and operating and maintenance information meet the requirements of § 10- P ys 9 P P This Certificate of Com fiance lists the buildin features and rformance ifications needed to corn with Title 24, Parts 1 and 6 of the All new DCV controls installed on new or existing packaged systems must be tested, e of programming different schedules for weekdays and weekends; incorporate an automatic holiday 'shut-off" eature P g PH 103 b and Title 24 Part 6, that turns off all loads for at least 24 hours, then resumes the normally scheduled operation; and has program California Code of Regulations. This certificate applies arty to building mechanical requirements. Equipment requiring acceptance testing _N/A that No.137195 backup capabilities that prevent the loss of the devices program and time setting for at least 10 hours if the The documentation preparer hereby certifies that the documentation is accurate and complete. i power is interrupted. Test Description Test Performed By: Ar Each space conditioning system shall be installed with an occupancy sensor to contra) the operating period'of the DOCUMENTATION AUTHOR SIGNATURE DATE ✓❑ MECH-2-A: Ventilation System Acceptance Document JQr CG4Cr�6 �''� P 9 ys P Y P g P ® or ca1�a GONr system • Variable Air Volume Systems Outdoor Air Acceptance s a coNr t�,�S� fi',gc1, Each space conditioning system shall be installed with a 4-hour timer that con be manually operated to control the The Principal Mechanical Designer hereby certifies that the proposed building d n represented in this set of construction —menta is consistent • Constant Air Volume Systems Outdoor Air Acceptance c,`� �.AIRi pro .\Cs -SIR J p operating period of the system. with the other compliance forms and worksheets, with the specifications, ith any other calculations submitted with this permit application. The Test required On all New systems bath New Construction and Retrofit. proposed building has been designed to meet the mechanical requirementanteing in the applicable parts of Sections 100, 101, 102, 110 through No.137195 ✓® MECH-7-A Supply Fan Variable Flow Control Acceptance Document Each space conditioning system shall be installed with controls that temporarily restart and tern orcril 'operate the EXP.1„3onoae P 9 Ys R y P Y' P 1 t 5 120 through t 25 14Z 144 and 145. � z PP y P No. 137195 system as required maintain a setback heating thermostat setpoint. ✓' N/A All new VAV fan volume controls installed on new or existing stems must be tested. o corer EXP,1 Equipment requiring acceptance testing � ®U^° * g systems e Rq Each space conditioning system shall be installed with controls that temporarily restart and temporarily operate the sr�Tr �G�s o�`'� v``��.AIR�H system as required to maintain a setback coolie thermostat setpoint ❑ The plans & specifications meet the requirements of part 6 (Sections 10-103a). of CAUL c, y q 9 P Equipment requiring acceptance testing N/A No.137196 ❑ The installation certificates meet the requirements of part 6 (10-1030 3). EXP.111302006 Each space conditioning system serving multiple zones with a combined conditioned floor area more than 25,000 sq. ft. shall be provided with isolation zones. Each zone shall: not exceed 25,000 sq. ft.; shall>be provided with isolation ❑ The operation & maintenance information meets the requirements of Part 6 (10-103c), ` devices, such as valves or dampers that allow the supply of heating or cooling to be setback or shut off ✓®MECH-3-A: Packaged HVAC; Systems Acceptance Document 9rc-4r independently of other isolation areas; and shall be controlled by a time control device as described above. Please check one: (These sections of the Business and Professions Code are printed in full in the Nonresidential Manual.) Test required on all New packaged systems both New Construction and Retrofit. �'�Q¢AIO"'r�r�,®� F of cI~u� Each space conditioning zone shall be controlled by an Individual thermostatic control that responds to temperature 'r within the zone. Where used to control heating, the control shall be ad)ustable down to 557 or lower. For cooling, ❑ thereby affirm that t am eligible under the provisions of Division 3 of the Business and Professors Code to sign this document as the person No.137195' the control shall be adjustable up to 857 or higher. Where used to control both heating and cooling, the control responsible for its preparation; and that I am licensed in the State of California as a civil engineer or mechanical engineer, or I am a licensed Equipment requiring acceptance testing N/A °`P'11 °` � ✓® MECH-8-A: Hydronic System Control Acceptance Document shall be capable of providing a dead bond of at least 57 within which the supply of heating and cooling is shut architect, 1lr r+� ^o off or reduced to a minimum. ® 1 affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537.2 or 6737.3 to sign this C4c ��ta� • Variable Flow Controls, Applies to chilled and hot water systems. Thermostats shall hove numeric setpoints in T. document as the person responsible for its preparation; and that I am a licensed contractor performing this work. F of cnuF • Automatic Isolation Controls, Applies to new boilers and chillers and the primary pumps are connected to a common header. Thermostats shall have ad° stible se P only authorized setpoint stops accessible onl to personnel. ❑ 1 affirm that I am eligible under the exemption to Divisron it p 3 of the Business and Professions Code to sign this document because pertains to e P . ✓® MECH-4-A: Air-Side Economizer Acceptance Document • Supply Water Temperature Reset Controls, Applies to new constant flow chilled and stricture or type.of work described pursuant to Business and Professions Code sections 5537, 5536, and 6737.1. P coNr Heat pumps shall be installed with controls to prevent electric resistance supplementary heater operation when the UC Test required on all new air-side economizers for both New Construction and Retrofit, Units with hot water systems that have a design capacity greater than or equal to 500,000 Aiid heating load can be met by the heat pump alone. Electric resistance supplementary heater operation is permitted PRINCIPAL MECHANICAL. DESIGNER-NAME SIGNATURE DA E gp Coyi� 137195-C20 economizers that are installed at the factory and certified with the Commission do not require �� acy Btu/hr• o� during transient periods, such as start ups and following room thermostat setpoint advance, when controls are CAL-AIR INC. ,o -AIR�N Q� No.137195 provided which use preferential rate control, intelligent recovery, staging, ramping, or similar control mechanisms _2 equipment testing but do require construction inspection. 4� 71 4' • Woter-loop Heat Pump Controls, Applies to all new waterloop heat pump systems 0P.,,soaoos 9 P Y P supplementary 9 9 y P Supplementary ❑ indicate location on plans of Note Block for Mandatory Measures No 13 95 where the combined looppumps are greater than 5 h deli red to preclude the unnecessary aeration of su lementar heating Burin the recover period. Su lementar EXP.11/34f2W6 P P 9 P• a heater operation Is also permitted during defrost. N A *a ^o* • Variable Frequency Control, Applies to all new distribution pumps on new variable rcac �`'a•� Equipment requiring acceptance testing / r INSTRUCTIONS TO APPLICANT MECHANICAL. COMPLIANCE & WORKSHEETS (check box if worksheet is included) sAr� G �� flow chilled, hydronic heat pump or condenser water systems where the pumps Ventilation ❑ MECH-I-C Certificate of Compliance. Part 1 of 3, 2 of 3, 3 of 3 are required on plans for all submittals. motors are greater than 5 hp. Controls shall be provided to allow outside air dampers or devices to be operated at the ventilation rates as specified Equipment requiring acceptance testing NLA in these plans. ❑ MECH-2-C Certificate of Compliance. Part 1 of 3, 2 of 3, 3 of 3 are required for oil submittals, but may be on plans. Gravity or automatic dampers interlocked and closed on fan shutdown shall be provided on the outside air Intakes and discharges of all space conditioning and exhaust systems. ❑ MECH-3-C Certificate of Compliance are required for all submittals with mechanical ventilation, but may be on plans. All gravity ventilating systems shall be provided with automatic or readily accessible manually operated dampers in all openings to the outside, except for combustion air openings. ❑ MECH-4-C Certificate of Compliance are required for all prescriptive submittals, but may be on plans. Air balancing: All space conditioning and ventilating systems shall be balanced to the quantities specified in these plans, in accordance with the NEEB or AABC National Standards (1986), Outside Air Certification: The system shall provide the minimum outside air as shown on the mechanical drawings, and shall be measured and certified by the installing licensed C-20 Mechanical Contractor. 2005 Nonresidential Compliance Forms April 2005 2005 Nonresidential Compliance Forms April 2005 2005 Nonresidential Compliance Forms April 2005 AIR SYSTEM REQUIREMENTS (Part 1 of 3) MECH-2-C WATER SIDE SYSTEM REQUIREMENTS (Part 2 of 3) MECH--2--C PROJECT NAME: ARCSIGHT DATE: 7/9/06 PROJECT NAME: ARCSIGHT DATE: 7/9/06 1HVAC MISC. PRESCRIPTIVE REQUIREMENTS: MECH-4---C AiR SYSTEMSM, Central or Single Zone PROJECT NAME DATE (S ARCSIGHT 7/9/06 ITEM or SYSTEM TAG WATERz SIDE SYSTEMS: Chillers Towers Boilers H dronic Loop s � N/A ITEM o SYS TEM STEM TAG(S)T:-24 N/A FAN POWERED CONFUMPTIONI 144 (c) MANDATORY MEASURES Section .......... ......... T-24 Heating Equipment Efficiency 112(a) MANDATORY MEASURES Section NOTE: Provide one copy of this worksheet for each fan systems with a total fan system horsepower greater than 25 hp for Constant Cooling Equipment Efficiency 112(a) Volume Fan Systems or Variable Air Volume (VAV) Systems when usin the Prescd tnre Approach. a Heat Pump Thermostat 112(b) Equipment Efficiency 112 a ® � Q a- Heat Insulation 123 ¢ Furnace Controls 112(c}, 1 t 5(a) PRESCRIPTIVE MEASURES FAN DESCRIPTION DESIGN EFFICIENCY NUMBER OF PEAKS WATTS Natural Ventilation 121(b) Minimum Ventilation 121(b) Calculated Capacity 144(a&b} BRAKE HP FANS B x E x 746 / (C MOTOR DRIVE x ®) _ VAV Minimum Position Control 121(c) Proposed Capacity 144(a&b) C� Demand Control Ventilation 121(c) Tower Fan Controls 144(h) N/A Time Control 121{c}, 122(e) Tower Flow Controls 144 h Setback and Setup Control 122(e) Variable Flow System Design 1440) Outdoor Damper Control 122(f) Chiller and Boiler Isolation 1440) z CHW and HHW Reset Controls 1440) Isolation Zones 122(g) Pipe Insulation 123 WLHP isolation Valves 144 ' ) (1) 1 TOTAL FAN SYSTEM POWER WATTS, SUM G� Duct Insulation 124 VSDonCHW, CW & WLHP Pumps>5HP 1440) FILTER PRESSURE ADJUSTMENT Evaluation. COLUMN F) PRESCRIPTIVE MEASURES DP Sensor Location 144(j) 144-A 2) SUPPLY DESIGN AIRFLOW (CFM) Calculated Heating Capacityz 144(o & b) A) if filter pressure drop is greater than 1 inch W.C. 3) TOTAL FAN SYSTEM POWER INDEX (Row 1 / Row 2)1 W/CFM Proposed Heatin Ca acit z 144 a & b 1:For each chiller, cooling tower,and hydronic loop or groups of similar equipment #ill in the reference to sheet number and/or specification section and paragraph number . . . enter filter pressure drop. Spa on line 4 and Total q. Spa g P y z where the required features are documented. if a requirement is not applicable, put N jA in the column. ) _ Calculated Cooling Capacity i44(a & b) Fan pressure SPr on Line 5, z 2:Water side systems include wet side systems using other liquids such as glycol or brine. 5) SPf Proposed Cooling Capacity 144(a & b) B) Calculate Fan Adjustment and enter on line 6. 6) Fan Adjustment = 1-(SPa - 1)/SPf Fan Control 144(c) DP Sensor Location 144(c) C) Calculate Adjustment Fan Power Index and enter on 7) ADJUSTED FAN POWER INDEX (Line 3 x Line 6)' W/CFM Supply Pressure Reset (DDC only) 144(c3 I Row 7. Simultaneous Heat/Cool 144(d) Z Economizer 144(e) 1. TOTAL FAN SYSTEM POWER INDEX or ADJUSTED FAN POWER INDEX must not exceed 0.8 w/cfm, for C V systemd or 1.25 z °.� 0Heat and Cool Air Supply Reset 144{f}` w/cfm for VAV systems Duct Sealing 144(k) a > 1: For each central and single zone air systems (or group of similar units fill in the reference to sheet number and or specification section and paragraph number where the required til features are documented. If a requirement is not applicable, put "NIA' in the column. 1 TEM Or SYSTEM TAGS 2: Not required for hydronic heating or cooling. Either enter value here or put in reference to plans and specifications per footnote 1, ` { I1.1 2005 Nonresidential Compliance Farms April 2005 2005 Nonresidential Compliance Forms April 2005 U_I PRESCRIPTIVE MESURES Section Reference on Plans or Specification' ,Q Electric Resistance Heating2 §144 (g) N/A N/A N/A N/A Z U Heat Rejection Systems #144 (h) N/A N/A N/A N/A -1 O Air Cooled Chiller Limitation §144 (h) N/A N/A N/A N/A 0- 1 Z MECHANICAL VENTILATION AND REHEAT MECH-3-C SERVICE HOT WATER&POOL REQUIREMENTS (Part 3 of 3) MECH-2-C N/A N/A N/A N/A PROJECT NAME DATE y c<) ARCSIGHT 7/9/06 PROJECT NAME: ARCSIGHT DATE• 7/9/06 1. Fill in the reference to sheet number and/or specification section and paragraph number where the required features are ® cV documented. If a requirement is not applicable, put "N/A' in the column. MECHANICAL VENTILATION {§121{b}2} REHEAT LIMITATION (§144(d)) Service Hot Water, Pool Heating 2. Total installed capacity (MBtu/hr) of all electric heat on this project exclusive of electric auxiliary heat for heat pumps if electric heat ® c,t AREA BASIS OCCUPANCY BASIS VAV Minimum ITEM or SYSTEM TAG(S) is used explain which exception(s) to t144(g) apply. z KI A B C D E F G H i J K L M N N/A 3. Are centrifugal fan cooling towers used on this project? (Enter Yes` or 'Nol If centrifugal fan cooling towers are used explain Revisions Design 30% of which exception(s) to t 144(h) apply. CFM Min Min REQ'D g Max of Design MANDATORY MEASURES T-24 Condition CFM Ventilation Air Design Columns Section Reference on Plans or S ecifidatlon 4. Total 'installed capacity (tons) of all chillers and air cooled chillers under this permit, If there are more than 100 tons of air-cooled Zone/ Per CFM by Num of CFM by V.A. Bx0,4 minimum Transfer Area Per cfm Zone H.J.K. Water Heater Certification §113(a) chiller capacity being installed explain which exception(s) tot 1440) apply. Project System (ft2) fie Area People Person Occupant Max of Supply cfm/ftz or 300 Air Air 1 1,B or C E x F D or G cfm cfm setpoint Water Heater Efficiency §113 b AV 1-1 405 0.15 61 4 15 90 91 95 N A N A N A N A - Service Water Heating Installation §113(c) 0.15 15 Pool and Spa Efficiency and Control §114(a) P 2005 Nonresidential Compliance Forms April 2005 0.15 15 Pool and Spa Installation §114(b) Q.15 15 §115 15 Pool Heater-No Pilot Light (c) ARCS IGHT C14 0.i5 15 Spa Heater-No Pilot Li ht §115(d) NOTE: 0.15 15 1:For each water heater, pool heat and domestic water loa or row of similar equipment) fill in the reference to sheet number and/ors ificaUon section and a 15 P g P "N/Amin ALL NEW MECHANICAL EQUIPMENT IS FOR PROCESS COOLING LOAD ONLY, 60 0.15 15 Ora ra h number where the required features are documented. if a re uirement is nit applicable, put the column. 0,15 15 ALL OTHER MECHANICAL EQUIPMENT IS EXISTING' AND PREVIOUSLY 0.15 15 COMPLIED, 5 RE TS WY. o Totals Column i Total Design Ventilation Air CUPMTM, CA N C Minimum ventilation rate per Section §121,Table 121-A. J E Based on fixed seat or the greater of the expected number of occupants and 50% of the CBC occupant loot for egress purposes for spaces without F- fixed seating. Title F-- H Required Ventilation Air (REO°D V.A.) is the larger of the ventilation rotes calculated on an AREA BASIS or OCCUPANCY BASIS (Column D or G), - i Must be greater than or equal to H, or use Transfer Air (column N) to make up the difference. C9 J Design fan supply cfm (Fan CFM)x3OX; or MECHANICAL Gam.? K Condition area (ft ) x 0.4 cfm/f ; or tY. L Maximum of Columns H,J,K, or 300 cfm TITLE-24 Q M This must be less than or equal to Column L and greater than or equal to the sum of Columns H plus N. Transfer Air must be provided where the Required Ventilation Air (Column H) is greater than the Design Minimum Air (Column M). Where required, 2VV TITLE $�/ �-Et�/ NO. N fronsfer air must be greater than or equal to the difference between the Required Ventilotion Air (Column H} and the Design Minimum Air (Column M), �„ 0 4 SYSTEM��1 Column H minus M. DUCTWORK LEAKAGE TEST N/A Project Manager Project Engineer a DUCT INSULATION R - 4.2 R - 8.0 DAB RSG Drawn By D tb l ` d DISTRIBUTION DUCTWORK N/A N/A 2005 Nonresidential compliance Forms April 2005 2005 Nonresidential Compliance Forms April 2005 RSG 4/9/07 ROOF DUCT N/A N/A Job Number Scene APPROVED FOR CONSTRUCTION ? o-o n SIGNATURE DATE Dwg. Number DRAFTSMAN: C4 ENGINEER: M11111111113 a a f F , it it it it it it it it it it it it OFFICE DOUBLE OFFICE it it it REDWOOD MY ELWMC,INC. it , DOUBLE OFFICE � 124 _— ....... ......._,.._....,.__...------___,_.-------------------------,_,.----------•---- OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE OFFICE } El Con rs-Lic.#318433 16 ail 163 1 I6I I 1 I2 128 Hazel Redwood C' CA I i it � �' � 114 Ave,», �9 PATIO CONFERENCE ., _ _..........._.. Tel:(650)369-5555 Fax(650)369-4963 ;F I R f C Z OFFICE 0. ;....�, --- �� EXECUTIVE ADMIN. � .............---•-----------_ ..... ..... jr �c c°ti�•� 10 it 41303 < COPY r F t W. SHOWER, F: .' ., :: •, ., 1 .: �® ' „ HA _ :: QUIET RM,�>---� F: 15 ;; 15 F; :: .^ ;; "�Ctasstfication n LL 1 ; 1 STORAGE 13 136 ;_ �; 4 '� , , QUIET RM ' QUIET RM, 178-71 - .,.....,... -_ ., , f� • , , iiitt , iiittt i .. ., , f ' a..f s8 No , F } iittt ' 4 - .« ::t--- LOBBY , : . , , , , F F , „ • i r , . e < , , „ it it -------------------- F I01 +7 -,._..... ELEV. EQUIP. L STAIR (E) STA .r--' �' 40 S �/ 0� L� WOMEN) COPY/FAX }i" £ CA+ F , „ • r `�. NO, 3 16i it F < ' F it :,�„•�. -r= � , ? This design is the exclusive property JAN, :, of Redwood City Electric, Inc. The , , , , , STORAGE }fig _ t,. ; drawings and blueprints containing r - =- :� ELI- OFFICE :N' 5zvz' = this desi n are and shall remain the 1 tr cs s :. ,z , � ': s 9`1 f tro ert o Redwaod Cit Electric..... .:...... ........ .....ram,......-�,.... , , RECEPTION F lnC. The dative of the or'r teal ....................------...:......« 1 Fy ,WPAP it prints or copies thereof does not SERVER ROOM r" 1I CONFERENCE�' � ;; i '-a , ro,• :?t,613iLtial: y , { �,\ constitute a publication thereof. + :F�,ital' MATCH, ._... These drawings or blueprint are F ' MEN S F F . _�• : z exhibited to you solely for the Q r--�-- purpose of transacting a sale by I F t 1Q8 ----_-"--- .. �� �, ��fi ,, �,. ���.. .,tom 4�EN'S -- Redwood Gity Electric, Inc. of the _,I4 =t __ _.. c SA QFFE �❑ _ __-_•_-. ~'. electrical system incorporated in ; he design. E PANEL �:1P . C E E}PANEL UPSB ;;' ' W. SHOWER Any communication of this design : . � without the consent of Redwood i Electric, Inc. constitutes a City E c t i r,F ®e Y , .. ;a.... violation of the lows of this state , F , y 7 • , , ; „ ti KVA .vit S ' .... F F OFFICE ` _.-...- - .._._.._.._....-. F t i I � � ' ;: ' 1 , d i :f h # + • pi5CONNECT (E) UPS `t';t r ;'• �• '_ .: +' SHOWER 1lid PLACE. REMOVAL OF yy,is :, , UPS BY (?TREKS. '�.r , t,, ,`��e , f •t `, i i` .I d f , r,.................. OFFICE OFFICE ,. ..,.... , e .. DOUBLE O ICE DOUBLE O ' t l 1•=. I f ;' I2Q 1 ! OPEN OFFICE `ti `. M. SHOWER OFFICE =s it s 13 �f; ;`y 104 I I ; := 1 C " MENit ' I ONFERENC I4 E Y 't t t�, x • --------------- „ + CONFERENCE r ::::::::::.....::::::::::::::::_:::::::::.,:.::.::: t „ AM r •- = OPEN OFFICE 1 1 _ 1 ! FAX/COPY I l , DOUBLE OFFICE JS.: ;, <A"f n.u' t • it t 1 H , 13 it NEW FEEDER: 2 SETS OF 1 (2"C- 4#4/4 & 1#2G) ! 1 CU, THHN/THWN ! i SCOPE OF WO � F STORAGE DOUBLE OFFICE , I I (E) STAIRit , , ii it I NO, 2 14 , , ti t TRAINING ROOMit { 13 CONFERENCE it i {, 1 (N) UPS (2)4 SEALTiTE ! 154KVA „ `_____, �{ 1 I STORAGE q; cAaB BATTERY ' F REMOTE -:::::.. .............. so -----sMOKI.` oETECTO . r :.,.:._...................... STAIR OFFICE c FIRE i DOUBLE O DOUB OFFI, 'tE) S CONNECT TO (E COFFEE ALARM; SYSTEM.' 11 1 SYS :N . 1 ! OI , , , STORAG E NEW FEEDER: 2. - 3 2 I 1 ! ...... it .... C THH H N it U, N� it '. A ........ COFFEE ( CB#1 BREAK ARE , „ BREAK AREA F } : 152 CONFERENCE T,25;;,,A • j .. ,. ,.................. .,.,.,..,............ _..._...,......_.__... _.., •, ` L (E) ELECT, RK TO MS8 0 RESULT WAY 4 REVISIONS 03-30-47 ISSUED FOR PERMIT . ... .. ... .,.. ,....... ..... ... ... .... .. ..... ... GFt — 1000/3 LINE TAP (E) 1000 A BUS FOR NEW 250A/3P CB (E)1000A, HOP, 277/480V, 30, 4W � NEW FEEDER: 2.5"C- 3250 KCMIL & 1#4G. 200/3 150/3 150/3 (E)90/3 (E)300/3 CU, THHN/THWN (MAX. 14 FT) (E) r ! NEW CBt: 225A/3P `! G - G G G G G #250 MCM CU. o IN NEMA 1 ENCLOSURE _ -----GROUND I WITHIN 10' FROM (E) DIST. 25t}/3 -- ---- --- — __ PANEL HDP. (E) (E) 'y, <#---2"C-Wf 1th"C-Wj (E) NEW FEEDER: 2.5"C- 3 254 KCMIL & 1 4G. I 4#3/0 CU. 3#1/0 CU. FEEDER aL METAL COLD WATER PIPE CU. THHN/THWN ; & 1#6G & 1#6G STRUCTURE STEEL a .10: I NEW UPS (E) (E) ELJ (E)EIT (E)oni TRANS OR�MER"T1" GROUND ROD !' 154KVA l AG-1 AC-2 ELEVATOR 48OV-120/208V 2208/120V OUTPUT I Sao/3 i' - JOB NO X/Ac (E) 7124 DATE 1 I 03-30-2007 I ! ''A"C-W/ — — DRAWN 4#2 CU. -` _-___"`k SN & 1#8G I ' E4 400A i (E)600/ CHECKED CN ' tt: (E)800A, LDP, 120/208V, 30, 4W ' #1 CU GRD. ( GROUNDING AS 1 ! SCALE :a ! PER 2044 CEC. ( H2 225/3� 225/3� 225/3 1 f8 =1 —0 ! NEW FEEDER: 2 SETS OF ! (E) (2"c- 4#4/4 & 1#2G) SHEET TITLE U CU, THHN/THWN (E) 2�,4"C—W/ T 4#4/0 CU. 1 R :w wF _. x & F#4G POW-9R PLAN U COPE OF WO 400A;3) UP A UFSB Ll LIA L2 L2A L3 MA (E) {E} (E) (E) (E) (E} (E) (E) A SHEET NO. Ea "Id SINGLE L DIAGRAM1ST OWER R 2N OW OAR E-4*2 SHEET 1 OF 1 .. .� N