Loading...
2013 S-39 Replacement Pages CUPERTINO, CALIFORNIA Instruction Sheet 2013 S-39 Replacement Pages REMOVE OLD PAGES INSERT NEW PAGES TITLE 16: BUILDINGS AND CONSTRUCTION 94C, 94D 94C, 94D LMB (7/13) 94C Green Building Standards Code Adopted 16.58.210 ! 16.58.210 Section 101.10.1.1.9-Added. 16.58.220 Table 101.10-Added. Add Section 101.10.1.1.9 to read as follows: Add Table 101.10 to read as follows: 101.10.1.1.9 Mixed-Use - as set forth in Table 101.10. (Ord. 12-2099, § 1 (part), 2013) Project Type Minimum Green Building Required Verification Requirement A. NEW CONSTRUCTION Residential Single Family and Multi-Family • CALGreen Building Code in City Review homes equal to or less than 9 accordance with CALGreen's homes: minimum thresholds. Single Family and Multi-Family • GPR certified at minimum 50 Third Party GPR or LEED homes greater than 9 homes: points or certification as applicable • LEED Silver or • Alternate Reference Standard per Section 101.10.2 Alternate Reference Standard: See Section 101.10.2 Non-Residential Small, less than 25,000 SF: 0 CALGreen Building Code *per City Review Chapter 5 of the California Green Building Standards Code Mid-size, from 25,000 to 50,000 0 LEED Certifi.ed or Third Party LEED Certification SF: • Alternate Reference Standard Alternate Reference Standard: per Section 101.10.2 See Section 101.10.2 Large, greater than 50,000 SF: • LEED Silver or Third Party LEED Certification • Alternate Reference Standard per Section 101.10.2 Alternate Reference Standard: See Section 101.10.2 B. RENOVATIONS AND ADDITIONS a. Residential i. Single-family • CALGreen Building Code in City Review accordance with CALGreen's minimum thresholds. ii. Multi-family (minor): • CALGreen Building Code in City Review accordance with CALGreen's minimum thresholds. 2013 S-39 16.58.210 Cupertino-Buildings and Construction 94D Project Type Minimum Green Building Required Verification Requirement iii. Multi-family (major): • GPR minimum 50 pts or Third Party GPR or LEED Renovations and/or additions • LEED Certified or Certification as applicable with a Floor Area Ratio (FAR) • LEED EBOM Certified or increase z 50% and at least • Alternate Reference Standard Alternate Reference Standard: See 35,000 square feet, and that per Section 101.10.2 Section 101.10.2 replace or substantially alter the HVAC system and at least two of the following: building envelope, hot water system and lighting system. b. Non-Residential L Minor: Renovations and/or • CALGreen Building Code in City Review additions that do not meet the accordance with CALGreen's higher thresholds for "major minimum thresholds. renovations and additions" outlined as defined in (ii)below. ii. Major: Renovations and/or • LEED Certified(applicable only Third Party LEED Certification additions that comprise at least to the area of renovation/ 35,000 square feet, and replace addition) or or substantially alter the HVAC • LEED EBOM Certified or system and two of the • Alternate Reference Standard Alternate Reference Standard: See following: building envelope, per Section 101.10.2 Section 101.10.2 hot water system, and lighting system. Mixed-Use For new and renovation/addition projects with residential and non-residential components, the use shall comply by either: 1. Meeting the applicable requirements for each use; or 2. Meeting the applicable requirements for the use that comprises the majority of the project's square footage where uses are attached and/or combined in a building. Notes: "Major"renovations and/or additions apply only to the area of the renovation/addition unless the LEED EBOM Certified option is selected. *Chapter 5 of the California Green Building Standards Code (Cal Green Mandatory) requirements shall only be applied to elements included in the scope of a project, unless otherwise required by the California Green Building Standards Code. (Ord. 12-2099, § 1 (part), 2013) 16.58.230 Section 101.10.2—Added. Table 101.10. In making a determination in response to an application under this section, the Building Official may Add Section 101.10.2 to read as follows: allow an alternate standard if he/she finds that the proposed alternative standard complies with all of the following: 101.10.2 Alternate green building standards. The A. Addresses a comprehensive scope of green applicant may request to apply an alternate green building building issues including energy efficiency,water standard for a project in lieu of the minimum standards per efficiency, resource efficient materials, and y healthy building practices; 2013 S-39 Repl.