13060215 (2) CITY OF CUPERTINO BUILDING PERMIT It ILDING ADDRESS: 10377 LAS ONDAS WAY CONTRACTOR:SOLARCITY PERMIT NO: 13060215 OWNER'S NAME: SATESH MENON 3055 CLEARVIEW WAY DATE ISSUED:06/27/2013 OWNER'S PHONE: 4082429110 SAN MATEO,C 94402 PHONE NO:(650)638-1028 C3( LICENSED CONTRACTOR'S DECLARATION BUILDING PERMIT INFO: BLDG r ELECT PLUMB r License Class e•-W,lV Lic.# ff gj�j-/0 (` (' MECH RESIDENTIAL COMMERCIAL. Contractor._54501jelleCrry Date I hereby affirm that I am licensed under the pravisi• s of C apter JOB DESCRIPTION: INSTALL 17 ROOF TOP FLUSH-MOUNTED PV PANELS (commencing with Section 7000)of Division 3 of the Business&Professions (4.165 Code and that my license is in full force and effect. KW).UPGRADE(E)ELECTRICAL PANEL TO 100 AMPS I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. �LI have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$18000 APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is APN Number:36929038.00 Occupancy Type: correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments. PERMIT EXPIRES IF WORK IS NOT STARTED costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,the applicant understands and will comply WITHIN 180 DAYS OF PERMIT ISSUANCE OR with all non-point source regulations per the Cupertino Municipal Code,Section 180 DAYS.W r' • r ALLED INSPECTION. 9.18. Signature Date 7:2' 3' Issue. Date: to ❑ OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of RE-ROOFS: the following two reasons: All roofs shall be inspected prior to any roofing material being installed.If a roof is 1,as owner of the property,or my employees with wages as their sole compensation, installed without first obtaining an inspection,I agree to remove all new materials for will do the work,and the structure is not intended or offered for sale(Sec.7044, inspection. Business&Professions Code) 1,as owner of the property,am exclusively contracting with licensed contractors to Signature of Applicant: Date: construct the project(Sec.7044,Business&Professions Code). I hereby affirm under penalty of perjury one of the following three ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER declarations: I have and will maintain a Certificafl-of Consent to self-insure for Worker's HAZARDOUS MATERIALS DISCLOSURE Compensation,as provided for by Section-3700 of the Labor Code,for the performance of the work for which this permit is issued. I have read the hazardous materials requirements under Chapter 6.95 of the I have and will maintain Worker's Compensation Insurance,as provided for by California Health&Safety Code,Sections 25505,25533,and 25534. I will maintain Section 3700 of the Labor Code,for the performance of the work for which this compliance with the Cupertino Municipal Code,Chapter 9.12 and the Health& Safety Code,Section 25532(a)should I store or handle hazardous material. permit is issued. Additionally,should I use equipment or devices which emit hazardous air I certify that in the performance of the work for which this permit is issued,I shall contaminants as defined by the Bay Area Air Quality Management District I will not employ any person in any manner so as to become subject to the Worker's maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the Compensation laws of California. If,after making this certificate of exemption,I Health&Safety Code,Sections 25505,25533,and 25534. become subject to the Worker's Compensation provisions of the Labor Code,I must forthwith comply with such provisions or this permit shall be deemed revoked. Owner ora rb ized Z�/� Date: APPLICANT CERTIFICATION CONSTRUCTION LENDING AGENCY I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating I hereby affirm that there is a construction lending agency for the performance of work's to building construction,and hereby authorize representatives of this city to enter for which this permit is issued(Sec.3097,Civ C.) upon the above mentioned property for inspection purposes.(We)agree to save Lender's Name indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the Lender's Address granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section ARCHITECT'S DECLARATION 9.18. I understand my plans shall be used as public records. Signature Date Licensed Professional \ / ALTERNATIVE ENERGY PERMIT APPLICATION /1/\ J' COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION 4.,,j°() °O � A Li, 6.,.I9 10300 TORRE AVENUE•CUPERTINO, CA 35014-3255 � 0 (408)777-3228 • FAX(408) 777-3333 •buildinq(aDcupert rC orq CUPERTINO PROJECT ADDRESS // S j A-'N° OWNER NAME 3� q - HONE �I, znc n IL �a� �[Z-�I1 6 �� StME'v‘Uv.CezC3r>.ccr) Coe STREET ADDRESS I CITY,STATE.= 1 c G,f cr1 ,N.0Q, CA` l J of Pf CONTACT NAME ;� _ SO/ • `—` PHONE EMAIL I;Jk'�R� '^1 LV ��„JJ ` STREET ADDRESS CITY,STATE 71P 1 FAX 0 OWNER ❑ OWNER-BUILDER 0 OWNER AGENTCONTRACTOR 0 CONTRACTOR AGENT a ARCHITECT ❑ENGINEER ❑ DEVELOPER 0 TENANT CONTRACTOR NAME I I LICENSE NUMBER Q L :CENSE TYPE/'I / BUS Lt cx V. �vS�Y^^\ l bx -se l I� `1l -b o `l`7 COMPANY NAME I Q.4.'. 1 E eJ I .RC 61A,vG ��1-4-`may" _�1� l0Z STREET ADDRESS • LI 0/0 ARCHITECT/ENGINEER NAME LICENSE NUMBER I BUS.LIC a COMPANY NAME , E-MAD. FAX STREET ADDRESS CITY,STATE,Z:P PHONE USE OF )<SFD or Duplex 0 Multi-Family PROJECT IN WILDLAND ! PROJECT N STRUCTURE. 0 Commercial URBAN INTERFACE AREA ❑ Yes J No I FLOOD ZONE Yes - No • / i0 ;:i SOLAR PANELS 0 ELECTRIC VEHICLE CHARGING STATION 0 SOLAR WATER HEATING OTHER. FOR SOLAR PANELS: NUMBER OF PANELS/UNITS. KILOWATTS(COMMERCIAL ONLY). TOTAL V.AL LAT:ON-`� eo DESCRIPTION OF WORK - ,•, 4.0k l —-E-Csp / '.L'c - rn A p0>,els 1�S Ku..) 4 L,Qq r ai\el e- -e-c_- ; C cr 1 e 1 C e_ 1:3 By my signature below,I certify to each of the following: I am the property owner or authorized agent[�o act an the property owner's behalf `have read this application and the information I have provided is correct. I have read the Description of Work and verify it:s accurate, i agree to comply-.vith all appl;caole;coal ordinances and state laws ing to•uI .m• sentattves ofCuperino to enter the above-iden led property for Inspection purposes. Signature of Applicant/Agent: '---.I111,-----/40.011� Date: Z Z // 3 i'• u� RMATION REQUIRED .. OF&ICE USE ONLY OVER-THE-COUNTER _ F• L-I EXPRESS W CJ ❑ STANDARD :J S 0 LARGE 0 MAJOR PV,App_2011.doc revised 03/16/ i CITY OF CUPERTINO FEE ESTIMATOR—BUILDING DIVISION ADDRESS: 10377 LAS ONDAS WAY DATE: 06/27/2013 REVIEWED BY: MELISSA 41'1!to APN: 369 29 038 BP#: *VALUATION: $18,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY PENTAMATION SFD or Duplex PERMIT TYPE: SOLAR-RES USE: A WORK INSTALL 17 ROOF TOP FLUSH-MOUNTED PV PANELS (4.165 kW). UPGRADE (E) ELECTRICAL SCOPE PANEL TO (00 AMPS 1 in Check I I Plumb.Plan Check I I Elec.Plan Check 'ICJ hrs $0.00 NI,. Plumb. I Elec.Permit Fee: 1EPERMIT ech. Ins!, n Other Plumb hasp n Other Elec.Insp. 0.0 hrs $45.00 Plumb. Insp.Fee: Elec.Insp. Ire: NOTE: This estimate does not include fees due to other Departments(Le.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc.). These fees are based on the preliminary information available and are only an estimate. Contact the Dept for addn'l info. FEE ITEMS(Fee Resolution 11-053 E9' 7/1/12) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 1 # Alternative Energy System Supp1.PC Fee: 0 Reg. 0 OT 0.0 hrs $0.00 $219.00 IPHOTOVRES Photovoltaic System i PME Plan Check: $0.00 200 amps Electrical Permit Fee: $0.00 $45.00 1BELEC200 Services Supp1. Insp.Feee Reg. 0 OT 0.0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $45.00 1 Construction TsX: AdministrativeIADMIN $42.00 0 Fee: Work Without Permit? 0 Yes Q No $0.00 0 Advanced Planning Fee: $0.00 Select a Non-Residential 0 Travel Documentation Fee: 1TRAVDOC $45.00 Building or Structure Q Strong Motion Fee: 1BSEISMICR $1.80 Select an Administrative Item Bldg Stds Commission Fee: 1BCBSC $1.00 SUBTOTALS: $134.80 $264.00 TOTAL FEE: $398.80 Revised: 04/29/2013 • \^/ Building Department / • City Of Cupertino 10300 Torre Avenue 4.,5�. 1. Cupertino,CA 95014-3255 Telephone: 408-777-3228 CUPERTINO Fax: 408-777-3333 CONTRACTOR/SUBCONTRACTOR LIST JOB ADDRESS: I O31 9— /14/,41t v1377- RD PERMIT# / 3u 6bZl.� OWNER'S NAME: S)9 1g ,t,t,ert/onoi PHONE# GENERAL CONTRACTOR: Se4 T Ly BUSINESS LICENSE#,. ADDRESS: 30 S3— Clec✓ CITY/ZIPCODE: *Our municipal code requires all businesses forking in the city to have a City of.Cupertino:<business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL BE SCIHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINEWA,CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: /d ' a 9/13 Signature Date Please check applicable subcontractors and complete the following information: V SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE# Cabinets &Millwork Cement Finishing Electrical Excavation :. Fencing Flooring/Carpeting Linoleum/Woody Glass/Glazing Heating Insulation Landscaping Lathing Masonry Painting/Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile Owner/Contractor Signature Date ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING FLASHING WILL BE PAINTED TO MATCH EXTERIOR 51Z� 'q 'ONllw�d AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN — / ��_ Ida BLDG BUILDING POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. Installing 18-roof top flush-mounted panels (4.165kW), ---... "00,..-_-__:„..- A: CONC CONCRETEUpgrading ^^ i`=;a;S ao aoueul : Electrical Service to !.- 2. EACH UNGROUNDED CONDUCTOR OF THEo su. DC DIRECT CURRENT MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED uo!}p!o!A ay;}o levo :- JO SUB o due}o EGC EQUIPMENT GROUNDING CONDUCTOR BY PHASE AND SYSTEM PER ART. 210.5. APN:369-29-038 ION 11VHS suo!eo!!Dads pue ueld s(y;}o 6u delay eq (E) EXISTING } } ! +'a41 3. A NATIONALLY-RECOGNIZED TESTING lelo!`JO 6u!pl!n8 ayl W04 lenoadde}noy;!M'woe}eAay} EMT ELECTRICAL METALLIC TUBING LABORATORY SHALL LIST ALL EQUIPMENT IN a'e1nap o;JO'GLUM uo suo!;eye;le�o se6ueyo GALV GALVANIZED COMPLIANCE WITH ART. 110.3. �Ue a�eiu1e4 o GEC GROUNDING ELECTRODE CONDUCTOR 4. CIRCUITS OVER 250V TO GROUND SHALL ay}+e'+JCI eq}In}Helen s!;l •uo!;ons;suoo 6uunp a}!s got 1Sf1W suo! eo! loads pue sueid o as s CND GROUND COMPLY WITH ART. 250.97, 250.92(B) } }' I ; } 1y1 I HOT DIPPED GALVANIZED 5. DC CONDUCTORS EITHER DO NOT ENTER O2AO�It���/ I CURRENT BUILDING OR ARE RUN IN METALLIC RACEWAYS Q oNI1H3df10- Imp CURRENT AT MAX POWER vi 1N36N1�1dd3aIN3� ;N101If1e CUPERTINO Isc SHORT CIRCUIT CURRENT OR ENCLOSURES TO THE FIRST ACCESSIBLE DC CUOMOO tom, •ii,, uwnwwo DISCONNECTING MEANS PER ART. 690.31(E). r nuilding Department kVA KILOVOLT AMPERE C'Y7� 3 _, =W� kW KILOWATT 6. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS ' LBW LOAD BEARING WALL ? Z MIN MINIMUM REQUIRED BY UL LISTING. ___ .-40I / � JUN �' 2013 (N) NEW 7. MODULE FRAMES SHALL BE GROUNDED AT THE _=.'. NN*NC V= REVIEWED FOR CODE COMPLIANCE NTS NOT TO SCALE UL-LISTED LOCATION PROVIDED BY THE OC ON CENTER MANUFACTURER USING UL LISTED GROUNDING ' �t Reviewed By: J;"/ /7/7 PL PROPERTY LINE HARDWARE. P01 POINT OF INTERCONNECTION 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE PV PHOTOVOLTAIC BONDED WITH EQUIPMENT GROUND CONDUCTORS > • AND GROUNDED AT THE MAIN ELECTRIC PANEL. SCH SCHEDULE SS STAINLESS STEEL 9. THE DC GROUNDING ELECTRODE CONDUCTOR )FFICE COL STC STANDARD TESTING CONDITIONS SHALL BE SIZED ACCORDING TO ART. TYP TYPICAL 250.166(B) & 690.47. ' UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER • Voc VOLTAGE AT OPEN CIRCUIT VICINITY MAP INDEX W WATT 3R NEMA 3R, RAINTIGHT � ,� � ,. -- - . ,4p�•.• ..- lam' La_ *a_-V ++. , -404 i ,,„ : (.r. .". li-11 t ` • .. "� rte 1 PV1 COVER SHEET 6 i p,,., .-''.�..::"f '� � 'i y 7� yrZ� PV2 SITE PLAN s Ave , . , ' .-7,'16-,:<111_A r - - ' PV3 STRUCTURAL VIEWS tillpli[ �_ ""'' i ,1 "• " '>4 . '' 0*, PV4 UPLIFT CALCULATIONS y ill e tiC.1lo • `' - ,. . %;< - _ `0 .Ca / '� PV5 THREE LINE DIAGRAM LICENSE GENERAL NOTES - i i -.gip .a �— ��.. , '--�.�rlsan Park PV6 ELECTRICAL CALCULATIONS 1 1 Ctvm Centerf 4i.,; , • ,, .i- + „r'. >...Y. _ PV7 ELECTRICAL CALCULATIONS CA 888104 1. THIS SYSTEM IS GRID-INTERTIED VIA A 'i1kr �" µ �`i I =� ► �' ' Cutsheets Attached # 0 = .... t , ,:11-.- . f ear D 1_ ,1, C-46, C-10 UL-LISTED POWER-CONDITIONING INVERTER. .. 0 . '"M `++r., • w p. u c�: ,ID * `r,....r , ..cD=" 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. , � oorTIcCSE r =, •+ .t. .' " Y�EC�� 3. PHOTOVOLTAIC SOURCE AND INPUT CIRCUITS AND tt,„,„1.1Uf �N` x �_ ®` �INVERTER INPUT CIRCUIT ARE UNGROUNDED. ' j �' "';* i '�` 4° e C ..� • '' \�eP Mg MODULE GROUNDING METHOD: SLEEKMOUNT 4. SOLAR MOUNTING FRAMES ARE TO BE GROUNDED .14 fD . . , moi;,-`fir ` ; �q `'' 0� ,�J 5. ALL WORK TO BE DONE TO 2010 CALIFORNIA - ".,,L„,„,, ,- -Ji%0 I ..� , , tri y \ AHJ: Cupertino BUILDING CODE. `�' ` +rr a'. 'Q N ' Jo e, d REV BY DATE COM�IENI'�- - _.___- 6. ALL ELECTRICAL WORK SHALL COMPLY WITH THE ° Pac Ifi Hca'D r x r. '�: .� ,, 4 1 Q��, P F�� to :�"` f W 4 `} •� y . . 6/13/2013 COMMENTS 2008 NATIONAL ELECTRIC CODE AS AMENDED BY "'' �rf� �; SuISUD �f �� ASO ©©© -- � " � e ia�. , THE 2010 CALIFORNIA ELECTRIC CODE. • t �,,, w �`� ,,. ©©© UTILITY: Pacific Gas and Electric Company (PG&E) �►- '''"' • s .'� P!' i.' ► ++ ?t 1.1 I re ' I e.�.J'V.4 Y t t-1C �, .0 ' ip. rtT� 'm' a _®©© CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J —9501873 00PREMISE OWNER: DESCRIPTION: DESIGN: `0,,' CONTAINED SHALL NOT BE USED FOR THE MENON, SATISH MENON RESIDENCE Armand DeBose ..z.�� NOR BENEFIT SHALL ITN BEN DISCLOSED IN WHSOLARCITY OLE ORCIN MOUNTING S»N: 10377 LAS ONDAS WAY 4.165 KW PV Array1�� SolarCity CompMount Type C with Lifter PART TO OTHERS OUTSIDE THE RECIPIENTS � �� '%1 a ORGANIZATION, EXCEPT IN CONNECTION WIN MODULES: CUPERTINO, CA 95014 NE SALE AND USE OF THE RESPECTIVE (17) TRINA SOLAR # TSM-245PC05/PA05.18 PAGE NAME: SHEET: REV: DATE: Sal Clearvew Way an Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650) 638-1029 PERMISSION OF SOLARCITY INC. CIT POWER-ONE ; AURORA PVI-3.6-OUTD-S-US-Z (408) 242-9110 COVER SHEET PV 1 6/13/2013 (888)—SOL—MY(765-2489)www.ealarcItm y.ao ' 1� PITCH: 18 ARRAY PITCH:18 '6,, MP1 AZIMUTH: 179 ARRAY AZIMUTH: 179 1 „Somerset m 00 MATERIAL: Comp Shingle STORY: 2 Stories PITCH: 18 ARRAY PITCH:18 Ai Some?F,;ralt MP2 AZIMUTH:269 ARRAY AZIMUTH: 269 MATERIAL: Comp Shingle STORY: 2 Stories v. " `:� PITCH: 18 ARRAY PITCH:18 T •: Y'r er MP3 AZIMUTH:89 ARRAY AZIMUTH:89 4°, • MATERIAL: Comp Shingle STORY: 2 Stories s. 1 i , e. ARRAY AREA: 305 SQ.FT. i ! ., , i w ;:6--...t.,( COVERED:; 1�4 DK w „ i ;F 9 Department . � P " #,„ , 4 k! j U� - T 0'J3 ',�: '''4, ," '" '''' •.,\• : , REVIEWED FOR CODE COMPLIANCE , �, • .�.-. Reviewed By j;7.i SRT LEGEND O (E) UTILITY METER & WARNING LABEL ® INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS �H DC DISCONNECT & WARNING LABELS i--i AC DISCONNECT & WARNING LABELS ;� 0 JUNCTION BOX 3 N O DC COMBINER BOX & WARNING 0 G. • a °0 DISTRIBUTION PANEL & WARNING o • E m 00 - LC LOAD CENTER & WARNING LABELS El Q o o Q 0 e, i • O M DEDICATED PV SYSTEM METER 0 ■■ 0 0 10377 Las Ondas Way CONDUIT RUN ON EXTERIOR --- CONDUIT RUN ON INTERIOR — 2 _ I � o o GATE/FENCE ° --- INTERIOR EQUIPMENT , o o ■■ � ' 1 1 AC Tom- % SITE PLAN N e--- _ -� 1 �L_J��Inv, Scale: 1/8" = 1' w �7 E O IIII �� 0 1' 8' 16' �. .,,,� S CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: UB-9501 873 00 MENON, ..- - PREMISE OWNER: DESCRIPTION: DESIGN: �,,�" CONTAINED SHALL NOT BE USED FOR THE SATISH MENON RESIDENCE Armand DeBose -44.-SolarCity BENEFIT OF ANYONE EXCEPT SOLARCITY MOUNTING SYSTEM: 10377 NOR SHALL IT BE DISCLOSED IN WHOLE OR INC.,., Comp Mount Type C with Lifter 10377 LAS ONDAS WAY 4.165 KW PV Array PART TO OTHERS OUTSIDE NE RECIPIENTS I 1 ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES C U P ER TI N 0, C A 9 5014 11 3055 a� w Way THE SALE AND USE OF THE RESPECTIVE (17) TRINA SOLAR # TSM-245PC05/PA05.18 PACE NAME: SHEET: REV. DATE Son Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638 1029 PERMISSION OF SOLARCITY INC. POWER-ONE # AURORA PVI-3.6-OUTD-S-US-Z (408) 242-9110 SITE PLAN PV 2 6/13/2013 (888)-SOL-CITY(765-2489)www-eo-1029.com 5" 1111* ® , 5" (E) 2x6 \ (E) 2x6 e f• �. ______. ii 13' -/ 1 13'-3" / 1Li (E) LBW 1'-2" (E) LBW ' SIDE VIEW OF MP2 RAFTER: (E) 2x6 ® 24" O.C. SIDE VIEW OF MP1 RAFTER: (E) 2x6 ® 24" O.C. 6 CEILING JOIST: (E) 2x6 i, 16" O.C. A NTS CEILING JOIST: (E) 2x6 ® 16" O.C. — NTS MAX SPAN: 13'-0" MAX SPAN: 13'-3" MAX STANDOFF DISTANCE: 72" O.C. - MAX STANDOFF DISTANCE: 72" O.C. V = CUPERTINO � Building Department 7 JU 27 2013 REVIEWED FOR CODE COMPLIANCE Reviewed By: ��,� PV MODULE PV MODULE 5/16" BOLT WITH LOCK 5/16" BOLT WITH LOCK & FENDER WASHERS INSTALLATION ORDER & FENDER WASHERS INSTALLATION ORDER (6) (6) ZEP LEVELING FOOT LOCATE RAFTER, MARK HOLE ZEP LEVELING FOOT LOCATE RAFTER, MARK HOLE (1) LOCATION, AND DRILL PILOT (1) LOCATION, AND DRILL PILOT ZEP ARRAY SKIRT ZEP ARRAY SKIRT �;:;INEWANNEMO HOLE. �� �i�M M M �M HOLE. , ,-__ ,. .._ �� SEAL PILOT HOLE WITH SEAL PILOT HOLE WITH -�;: (4) —S- (2) (4) (2) POLYURETHANE SEALANT. ZEP COMP MOUNT C POLYURETHANE SEALANT. ZEP COMP MOUNT C ZEP FLASHING C II (3) (3) INSERT FLASHING. ZEP FLASHING CII (3) il (3) INSERT FLASHING. :„".r" --"r_" E COMP. SHINGLE !��� �� (E) COMP. SHINGLE m�;� l� (4) PLACE MOUNT. O (4) PLACE MOUNT. (E) ROOF DECKING (E) ROOF DECKING / NMMEMMI INSTALL LAG BOLT WITH (5) INSTALL LAG BOLT WITH 5/16" DIA LAG BOLT (5) SEALING WASHER. 5/16" DIA LAG BOLT (5) (5) _ SEALING WASHER. WITH SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH WITH SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES INSTALL LEVELING FOOT WITH (2-1/2" EMBED, MIN) (6) BOLT & WASHERS. (2-1/2" EMBED, MIN) C BOLT & WASHERS. (E) RAFTER ( 0 RAFTER STAN DOFF el STANDOFF Scale: 1 1/2" = 1' Scale: 1 1/2" = 1' CONFIDENTIAL- THE INFORMATION HERON J08 NUMBER: J B-9501 873 00 Txt EE OWNER: DESCRIPTION: DESIGN: `044 CONTAINED SHALL NOT BE USED FOR THE �=BENEFITOFANYONEEXCEPTSOLARCITYINC., MNGSYSTEM: MENON SATISH MENON RESIDENCE Armand DeBoseNOR SHALL IT BE DISCLOSED IN NMOLE DR IN Comp Mount Type C with Lifter 10377 ALAS ONDAS WAY 4.165 KW PV ArraySoIarCity PART TO OTTERS OUTSIDE THE RECIPIENT'S MULES: CUPERTINO, CA 95014 /Pr.... ORGANIZATION,EXCEPT IN CONNECTION WITH ! ' THE SALE AND USE OF NE RESPECTIVE (17) TRINA SOLAR # TSM-245PC05/PA05.18 s101515. a�°'"�'Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERIEk PACE NAME: SHEET: REV DALE L(650)638-t028' F:(650)638-1029 PERMISSION OF SOLARCITY INC. POWER-ONE # AURORA PVI-3.6-OUTD-S-US-Z (408) 242-9110 STRUCTURAL VIEWS PV 3 6/13/2013 (688)-sa-CITY(765-2489)ww.aobarcIty.com _ UPLIFT CALCULAT ,;Ai� ;= ` " `' Building Department REVIEWED FOR CODE COMPLIANCE (1/1) 5" (E) 2x6 Vie, Reviewed '11 i'11 ///AT Version ' 12.4 solarcity Wind Uplift Calculator on � , .w.. . . ,,. , ,a, .., , , , m� CategII PVRisk`System Toryyepe SolarCity�Sleeld•lount'" —/ 13'-6" / Comp Roof Comp Roof 1'-2"r (E) LBW #of La • , Com. Roof On 1 Roof Slope 18° SIDE VIEW OF MP3 RAFTER: (E) 2x6 i 24" Rafter _.•n e 24"O.C.O.C. PV Module Orientation Landscape CC) NTS CEILING JOIST: (E) 2x6 0 16" O.C. Total Area of Array 2999sf PV Module Width 3.3 ft MAX SPAN: 1S-6" PV Module Length 5.4 it MAX STANDOFF DISTANCE: 72" O.C. Attachment T pee Com• Mount T A.- C with Lifter `,,, . 3 r:e �•2'g-n'� .. -4," -z'.°rr" ' '�, ¢ � a o- x t sr .' s. V:tr;-. ,fy, ', . i r r 4i �iO.Q.'- . ,ASCE`Table 71 • Roof Snow Over��PVVModules��� _ 0.0 , f9fl tl . .t71, :WA*&koas r, .kid. ml fid 4 ww✓;ry ^gyp," srz`'�f d^.r 8Y4F^ w W Mfr;k y ami d W rc' f✓4 g r,d < 4 ;1 's sir dr p Yr" d" 'ono 4 , .„ L.m. Ud 6L �a ..bu�R ." w .�§tides�N'i�"�i °,u�""r.a `�R y.l, ) gn t daft' it;',Z, .e .,, „d^ .), �," ,, a.�! Wind Design,Code ASCE 7-05 PV MODULE `V V I' .., . , . . rttalhi/Fulli MO r . .. " cWind e V 85m R 6-1 tai 5/16 BOLT WITH LOCK .. ,M ",4 . ,', l,, a,etia `%e...t _ ) °'.1.1" J,V i* < '. . - .,ez.„1.,� �,r, 4.01,„� & FENDER WASHERS (6) INSTALLATION ORDER Roof Gable Roof Fig 6-116/C/o-1. p ZEP LEVELING FOOT LOCATE RAFTER, MARK HOLE Least Horiz Dim.of Bulldl LHD 30 ft (1) LOCATION, AND DRILL PILOT .IA f,., `it , r: ' `° '1 �a, ^:..,'°'.4.-..51.44,-Y',.. :, '-i - :"r".'' i ,f; �. %,ii ZEP ARRAY SKIRT 4i'.la AIalalal�F ia;:c' * - HOLE. Roof Wind Zone Wldth a 3 ft Y �1 SEAL PILOT HOLE WITH I ' i 1, .. �: (4) � (2) Wind Prestore 4e a re 0.85 }Tabte 6-3 POLYURETHANE SEALANT. r.'; .< ti,, "N'F, ,r :- iiI - ?; t°,. .-� P_;_3- $kms , ,4, _ .r"w.','4 ZEPCOMP MOUNT C Wind DI �_ ,4",:, Fader Kd ii 85 Table 6.4 El 3 INSERT FLASHING ?: ' �......_..., ,„.? ... ,3-_,a allai.,?`"a� -, :_'L--r t` a ." fir :. ^ _� '�f rr "a T ` i ZEP FLASHING C (3) O ” s 6 5 �z�j v_ due OXY n Ore qtr 4b=»:nam tali 3 a cam)N�2.713.— �m Equation6-15.: (E) COMP. SHINGLE vi ;�� I�� (4) PLACE MOUNT. ! r�*- „ e e 1308 t i1a/U 4n/6 t f _ r „,,:f,,,,,,,,-%,1,,,,,:..,,,,,,,,,,, : r ray per.0 aan t� r r ''',',','!,.'„2:,',:,!,`'' stn. '�” •,,. '' W� fr'i (E) ROOF DECKING INSTALL LAG BOLT WITH a ` , ire ° Mon 6� 5/16" DIA LAG BOLT (5) (5)_ SEALING WASHER. 'r;;, ,1, "` "` ` ' ' imemil WITH SEALING WASHER LOWEST MODULE SUBSEQUENT MODULES (6) INSTALL LEVELING FOOT WITH (2-1/2" EMBED, MIN) BOLT & WASHERS. ] j E, . , b . r Max Allowed Foot X-Spadng Landscape 72" (E) RAFTER Mak'AliowedXCantilever' Landscape 24" Max Standoff Tributary Area TrIbCL 20 sf 0 STANDOFF PATI W„ 3 psf Scale: 1 1/2" = 1' WLUP 0.6 DLPVcos(0) TCL -195 lbs Attachment Uplift Capadty Tallow , 637 lbs T• allow DCRLand 30.6% CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER JB-9501873 00 PRISE OWNER: DESCRIPTION: DESIGN: ��tee CONTAINED SHALL NOT BE USED FOR 1HE MENON, SATISH MENON RESIDENCE Armand DeBose BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 10377 LAS ONDAS WAY Sol arCI ty NOR SHALL IT BE DISCLOSED IN WHOLE OR IN _ PART TO OTHERS OUTSIDE THE RECIPIENT'S Comp Mount Type C with Lifter 4.165 KW PV Array Iji� ORGANIZATION,EXCEPT IN CONNECTION WITH 14wulz, CUPERTINO, CA 95014 Way THE SALE AND USE OF THE RESPECTIVE (17) TRINA SOLAR # TSM-245PC05/PA05.18 EET: " 3055 qe,CA 440 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: Sm Mateo,CA 94402 PERMISSION OF SOLARCITY INC. INVERTER 408 242-9110 T:(650)638-1028 F:(650)638-1029 POWER—ONE # AURORA PVI-3.6—OUTD—S—US—Z UPLIFT CALCULATIONS PV 4 6/13/2013 (888)-SOL-CITY(765-2489)www.edarcIty.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (N) GROUND ROD N 100A MAIN SERVICE PANEL - Inv 1: DC Ungrounded INV 1—(1)POWER-ONE # AURORA PVI-3.6-OUTD-S-US-Z LABEL: A —(17)IRINA SOLAR # TSM-245PC05/PA05.18 CA # 888104 AT PANEL WITH IRREVERSIBLE CRIMP (N) 100A/2P MAIN CIRCUIT BREAKER Inverter; 3600W, 240V, 96% PV Module; 245W, 222.9W PTC, 40MM, Black Frame C-46, C-10 Panel Number.TBD INV 2 Voc: 37.3 Vpmax: 30.7 Meter Number:PGE:1005904321 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER I MAIN SERVICE PANEL ADJUST MIN. ACTIVATION VOLTAGES! CUTLER-HAMMER Inverter 1 IND 1 {'00A/2P Disconnect () POWER-ONE 1 T DC+DO NOT ADJUST MIN.ACTIVATION VO TAGS AURORA PVI-3.6-OUTD-US-Z 1 DC- 1 String(s)Of 7 On MP 2 — (E) LOADS B J EGC /T\ 1 n Li ® r •U 2 -`�• \ I Q SET N.ACTIVATION VOLTAGE TO 20V y k _ GFP/GFCI•- PC+ I DC+ C- © (N)20A/2P —� N =Lam/ DG I l3 J G 1 String(s)Of 5 On MP 1 IM, m LO �'�-• 4,___22k_ r- ------�GND�-_ G C _❑ _DC+ - X1 • r' - G+L 1 String(s)Of 5 On MP 3 i, B N DG • I I GND I--- E-C'C- V� J (1)Conduit Kit 3/4"EMT N EGC/GEC � o- z-z CD I----GEC TO 120/240V SINGLE PHASE UTILITY SERVICE � CUPERTINO 1 << III � Building Department fr �' 13 REVIEWED FOR CODE COMPLIANCE Reviewed By: ;5•44.i4 POI-(i)Ground Rod; 5/8'x8',Copper B -(1)CUTLER-HAYNER 1 0G321UGB ACA —(1) 01MC4 DC Disconnect; 30A,240Vac,Non-Fusible,NEMA 1 Connector; MC4 U-Joint Connector,Male -(1)CUTLER-HAMMER/DGO3ONB Ground/Neutral Kit; 30A,General Duty(DG) -(1)SHOALS/STG.ICU.MMF.MC4 Connector; MC4 U-Joint Cpnnector,Female (1)ANG;10.THWN-2,Black (2)AWG#10,PV WIRE. Block Voc =186.5 VDC Isc =16.94 ADC (2)AWG#10,PV WIRE,Black Voc =261.1 VDC Isc =8.47 ADC ® §.-(1)AWG#10,THWN-2,Red O (1)AWG/10,Solid Bare Copper EGC Vmp =153.5 VDC Imp=15.96 ADC O (1)AWG X10,Solid Bare Copper EGC Vmp =214.9 VDC Imp=7.98 AIX (1)AWG jI10,THWN-2,White NEUTRAL Vmp =240 VAC Imp=16 MC If -(1)AWG/¢,THWN-2,Gr@en EGC/GEC -(1)Cronduit Kit 3/4"pAT (4)AWG#10,PV WIRE,Black Voc =186.5 VDC Isc =8.47 ADC O (1)AWG n0.Solid Bare Copper EGC Vmp =153.5 VDC Imp=7.98 ADC LLL��M (1)Conduit Kit 3/4'EMT CONFIDENTIAL-THE INFORMATION HEREIN JCB NUMBER: JB-9501 873 00 PREMISE OWNER: DESCRIPTION: DESIGN: `1664g CONTAINED SHALL NOT BE USED FOR THE MENON, SATISH MENON RESIDENCE Armand DeBose 1: NOR SHALL IBENEFIT OF T BEE EXCEPT DISCLOSED IN SOLARCITY INC.,IN MWNRNG CompS,rsoM 10377 LAS ONDAS WAY ')►�, soiarCitywWay PART TO OTHERS OUTSIDE THE RECIPIENTS Comp Mount Type C with Lifter 4.165 KW PV Array / ORGANIZATION, EXCEPT IN CONNECTION WITH MOOULES CUPERTINO, CA 95014 , 71 THE SALE AND USE OF THE RESPECTIVE (17) TRINA SOLAR # TSM-245PC05/PA05.18 3055 aE0'"lea Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: San Mateo,CA 94402 PERMISSION OF SOLARCITY INC. MVER1ER: T:(650)638-1028 F:(650)638-1029 POWER—ONE # AURORA PVI-3.6—OUTD—S—US—Z (408) 242-9110 THREE LINE DIAGRAM PV 5 6/13/2013 (888)-SOL-CITY(765-2489)wwrrealoraftycom 1. Conductor sper Art 690.8(B)(1) ELECTRICAL CALCULATIONS a. Conductor must deg have 30 deg. C ampacity >= 125% of continuous current per Art 215.2(A)(1). b. Conductor must have (after corrections for conditions of use) >= Module: 17 Trina TSM-245PC05.18 Black ZEP 222.9 Inv Pwr W PTC StrLen Voltage Drop Calculations Version 5_9.11 continuous current per Table 310.16. Inserter 1: 1 Power-One PVI-3.6-S 96.0% 4,000 3,638 Vdrop= (Imp) * (2*Length)*(Resistance) / (Vmp) Module: Imp(A) Max. Length(ft) Wire - C. Evaluate conductor temperature at terminations per 110.14(C). Inserter 2: String: 7.98 20 C AWG 10 at Max Are Hi: 85 deg F Ampacity of wire derated for conditions of termination must be Module: Vdrop= (7.98 A * 40 ft *0.00124 Ohms) / 195 V= 0.20% m p y Inserter 3: Branch: 7.98 60 C AWG 10 at Max Are Hi: 85 deg F >= continuous current*1.25. All string terminations are rated at Module: Vdrop= (7.98 A * 120 ft *0.00124 Ohms) / 195 V= 0.61% - 90' C. Inserter 4: Total voltage drop in DC conductors= 0.81% Inverter: 16.00 40 C AWG 10 at 240V 2. OCP Sizing per Art 690.8(B)(1) Total modules Total Inv Pwr 4,000 3,638 PTC Vdrop= (16.00 A * 80 it *0.00120 Ohms) / 240 V 0.64% a. Round up to next size per Art 240.4(B) Photovoltaic Module Electrical Specifications: Total STC 4,165 Combined 16.00 I 0 C AWG 10 at 240V Voc= 37.3 V deg F deg C Vdrop= (16.00 A * 0 ft *0.00120 Ohms) / 240 V 0.00% 3. Conductor Sizing per Art 690.8(B)(1) Vmp= 30.7 V Record Low Temp: 16 -8.88888889 Total voltage drop in AC conductors= 0.64% Isc= 8.47 A Max Average Hi Temp: 85 29.44444444 Total voltage drop in AC and DC conductors= 1.45% a. Conductor must have 30 deg. C ampacity >= 125% of continuous imp= 7.98 A current per Art 215.2(A)(1). Tvoc= -0.11936 V/deg C Power-One Strings Individual MPPT Tisc= 3.981 mA/deg C - b. Conductor must have (after corrections for conditions of use) >- String Type A and 2 Combined Strings Type A Voc Correction Method: ManufTvoc data Branch Circuit Type A 1-way wire length: 60 ft continuous current per Table 310.16. Power-One PVI-3.6-S 1 strings per branch 1 2 strings per branch 2 7 Trina TSM-245PC05.18 Black ZEP Inverter Min Vdc Input: 120 Vdc 7 modules per series string 5 modules per series strin c. Evaluate conductor temperature at terminationsper Art 110.14(C). Voc= 261.1 V Min Vmp at Max Temp: 195 Vdc Voc= 261.1 V 186.5 V p Vmp= 214.9 V Max Voc at Min Temp: 289 Vdc Vmp= 214.9 V 153.5 V Ampacity of wire derated for conditions of termination must be [so= 8.47 A Inverter Max Vdc Input: 600 Vdc Isc= 8.47 A 16.94 A >= continuous current*1.25. All branch terminations are rated at Imp= 7.98 A Max String Size: 14 Imp= 7.98 A 15.96 A 75' C min. Icont= 10.59 A Art 690.8(A)(1) 1-way wire length: 20 ft Icont= 10.59 A 21.18 A Art 690.8(A)(1) 1.a Conductor C AWG 10 PV Wire 2.a Conductor 1 C AWG 10 PV Wire 4. OCP Sizing Conductor 2 C AWG 10 PV Wire a. Round up to next size per Art 240.4(B) Conductor 1:Conductor 2: Icont*1.25= (Amps) 13.23 Icont*1.25=(Amps) 13.23 26. ___ CV t [_f�TI N® 5. Conductor Sizing per Art 690.8(B)(1) 30 deg C ampacity= 40 30 deg C ampacity= 40 -„:". 1.b Icont=(Amps) 10.59 2.b Icont=(Amps) 10.59 21, 9uildinq Departrnen' a. Conductor must have 30 deg. C ampacity >= 125% of continuous Start ampacity 40 Start ampacity 40 , current per Art 215.2(A)(1). Temperature derate(%=F) 0.71 Temp.derate(%=F) 0.71 7' i Conduit fill derate(%=#) 1 _ Cndt.fill derate(%=#) 0.8 0.8. _ J L.J b. Conductor must have (after corrections for conditions of use) >= Derated ampacity 28.40 Derated ampacity 22.72_ 22. continuous current per Table 310.16. Term 1 Term 2 V!EWEU FOR CODE COMPLIANCE 1.c Icont*1.25=(Amps) 13.23 Temp table 75degC 75degC ,l c. Evaluate conductor temperature at terminations per Art 110.14(C). Ampacity 40 2.c Icont*1.25= (Amps) 13.23 26' idevtewec By __ �tiy° Ampacity of wire derated for conditions of termination must be Ampacity 35 1.d Icont*1.25= (Amps) 13.23 2.d EGC C AWG 10 C AWG 10 Art.250.122 >= continuous current*1.25. All inverter output terminations are OCP size= 15 OCP size= 15 30 rated at 75' C. Inverter Type A Output Combined Inverter Output 6. OCP Sizing Power-One PVI-3.6-S 1-way wire length: 40 ft Service Voltage= 240 Volts a. Round up to next size per Art 240.4(B) icont= k ' Mr1 ;". ° A Art 690.8(A)(1) Total Inserter Power= Nameplate Watts 1-way wire length: 0 it 3.a Icont*1.25= (Amps) 20.00 A Art 690.8(B)(1) (cont=#of inserters*max inserter current Art 690.8(A)(1) 7. Conductor Sizing per Art 690.8(8)(1) OCP size= A Art.240.6(A) Icont=(Amps) O. Conductor must have 30 deg. C ampacity >= 125% of continuous 3.b Conductor C AWG 10 THWN-2 at 90 deg C:Table 310.16 4.a Icont*1.25=(Amps) 20.00 A Art 690.8(B)(1) Icont*1.25= (Amps) 20.00 OCP size= A Art. 240.6(A) current per Art 215.2(A 1 "' \ )O 30 deg Campacity= 40 4.b Conductora :F THWN-2 at 90 deg C:Table 310.16 3.c Icont= (Amps) 16.00 Icont*1.25=(Amps) : ( b. Conductor must have (after corrections for conditions of use) >= Start ampacity 40 30 deg C ampacity= At.'::' ; : I continuous current per Table 310.16. Temperature derate(%=F) 0.91 4.c Icont=(Amps) 16.00 Conduit fill derate(%=#) 1 Start ampacity "n C. Evaluate conductor temperature at terminations per Art 110.14(C). Derated ampacity 36.4 Temp.derate(%=F) Ampacity of wire derated for conditions of termination must be 3.d Icont*1.25=(Amps) 20.00 Cndt.fill derate(%=#) F Ampacity 35 Derated ampacity . >= continuous current*1.25. All inverter output terminations are 3.e EGC/GEC = D AWG 08 Art.690.47(C)(3), 250.166(B) 4.d Icont*1.25= (Amps) 20.00 rated at 75' C min. Amnarity vw.._.., -"' i CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J B-9501 873 00 PREMISE OWNER: DESCPoPTION: DESIGN: `%►14/ CONTAINED SHALL NOT BE USED FOR THE MENON, SATISH MENON RESIDENCE Armand DeBose A; �,. • BENEFIT OF ANYONE EXCEPT SN WHOLE INC., MOUNTING SYSTEM: 4 SOlarC�ty NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C with Lifter 10377 LAS ONDAS WAY 4.165 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS r~ ;� ORGANIZATION. EXCEPT IN CONNECTION WITH MODULES CUPERTINO, CA 95014 ,�, , � . THE SALE AND USE OF THE RESPECTIVE (17) TRINA SOLAR # TSM-245PC05/PA05.18 3055 Clear'1ew Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: San Mateo,CA 94402 PERMISSION OF SOLARCITY INC. INVERTER: T:(650)638-1028 F:(650)638-1029 POWER-ONE # AURORA PVI-3.6-OUTD-S-US-Z (408) 242-9110 ELECTRICAL CALCULATIONS PV 6 6/13/2013 (888)-Sal-CITY(765-2489)www.solaraity.com ELECTRICAL CALCULATIONS NEC 2008 220.82 -Residential Load Calculation Version 2.1 L1/L2 240 V NEC 220.82(B) "The general calculated load shall be not less than 100%of the first 10 kVA plus 40% of the remainder of the following loads..." NEC 220.82(B)(1) "The calculated floor area shall not include open porches, garages, or unused ... spaces..." Floor Area 0 square feet x 3VA/sq ft 0 VA NEC 220.82(B)(2) "1500 volt-amperes for each 2-wire, 20-ampere small appliance branch circuit and each laundry branch circuit..." Small Appliance Circuits 4 circuits x 1500VA/circuit 6,000 VA Laundry Circuits 4 circuits x 1500VA/circuit 6,000 VA Bathroom Circuits 3 circuits x 1500VA/circuit 4,500 VA NEC 220.82(B)(3) "The nameplate rating of all appliances... ranges, wall-mounted ovens, counter-mounted cooking &220.82(6)(4) units... clothes dryers that are not connected to the laundry branch circuit... [and] water heaters" 2P Breaker VA UNKNOWN LOAD 50' 9,600 UNKNOWN LOAD 30' 5,760 ✓ 0 ✓ 0 ' 0 ' 0 F 0 ✓ 0 ' 0 ✓ 0 ' 0 15,360 total VA Total of non air-conditioning loads: 31,860 total VA CUPERTINO First 8 kVA of load at 100% 9,0544BuildingDepartment Remainder of load at 40/° ,Adjusted total of non air-conditioning load 17,544 VAI i�-. �Ei:D ° .�U� 272013NEC 220.82(C) "Heating and air-conditiong load..." RVIFOR CODE COMPLIANCE 2P Breaker VA Sum of A/C Equipment Units 30' 5,760 Reviewed By ��„� �.; Sum of Electric Furnaces 0' 0 Total of A/C Loads and All Other Loads: 23,304 total VA Total Proposed Calculated Load: 97.10 Amps JB - 9501873 vSolarCity ©copyright SolarCity 2013 CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J B-9501 87 3 00 PREMISE OWNER: DESCRIPTION: DESIGN: ="I CONTAINED SHALL NOT BE USED FOR THE MENON, SATISH MENON RESIDENCE Armand DeBose 8- - ■ BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: j NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C with Lifter 10377 LAS ONDAS WAY 4.165 KW PV Array ��, S�Ia 'ty PART TO OTHERS OUTSIDE THE RECIPIENTS ,ri ;� ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES C U P E R TI N 0, C A 9 5014 ],�,,, • 3055 aearaew Way THE SALE AND USE OF THE RESPECTIVE (17) TRINA SOLAR # TSM-245PC05/PA05.18 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME: SHEET: REV: DATE: Son Mateo,CA 94402 PERMISSION C4 SOLARCITY INC. INVERTER T:(650)638-1028 F:(650)638-1029 POWER—ONE # AURORA PVI-3.6—OUTD—S—US—Z (408) 242-9110 ELECTRICAL CALCULATIONS PV 7 6/13/2013 (888)-SOL-CITY(765-2489)www.solarcity.com . CAUTION POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN: - Address: 10377 Las Ondas Way 0 INVERTER AND _ AC DISCONNECT Eu O (IN GARAGE) UTILITY ent SERVICE SOLAR `-,��"`1 OUPERTIrtrri.NO PHOTOVOLTAIC ON ROOF ! ildin PHOTOVOLTAIC BACK—FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL IS ' SUN 201 A/C DISCONNECT PER NEC 690.17 REVIEWED FOR CODE COMPLIANCE - OPERATING VOLTAGE = 240V MAX CURRENT = 16 A Reviewed By `jam,,; ,i% CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: JB-9501873 00 PREMISE OWNER: DESCRIPTION: DESIGN: `Oi//' CONTAINED SHALL NOT BE USED FOR THE MENON, SATISH MENON RESIDENCE Armand DeBose ..... .... � BENEFIT OF ANYONE EXCEPT SOLARCITY MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR INC.,., Comp Mount Type C with Lifter 10377 LAS ONDAS WAY 4.165 KW PV Array -� Solar��ty PART TO OTHERS OUTSIDE THE RECIPIENTSC U P E RTI N 0C A 9 5014 ,rGY .4 ORGANIZATION, EXCEPT IN CONNECTION WITH MODULES: , THE SALE AND USE OF THE RESPECTIVE (17) TRINA SOLAR # TSM-245PC05/PA05.183055 w Way SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PACE NAME: SHEET: REV: DATE: San Mateotto,, CA 94402 PERMISSION OF SOLARCITY INC. INVERTER: T:(650)638-1028 F:(650)638-1029 POWER-ONE # AURORA PVI-3.6-OUTD-S-US-Z (408) 242-9110 SITE PLAN PLACARD PV 8 6/13/2013 (888) SOL—QTY(765 246s)www.solorclty.com Label Location: Label Location: Label Location: CAUTION: SOLAR CIRCUIT (C) MAXIMUM AC _ (AC) (P01) A WARNING (P01) Per Code: OPERATING CURRENT Per Code: Per Code: CA Fire Guidelines MAXIMUM AC _ v CEC 690.54 INVERTER OUTPUT NEC 690.64.8.7 OPERATING VOLTAGE CONNECTION DO NOT RELOCATE Label Location: THIS OVERCURRENT PHOTOVOLTAIC DC (DC) (INV) DEVICE DISCONNECT Per Code: CEC 690.14.C.2 Label Location: PV SYSTEM (AC) (P01) DISCONNECT FOR Label Location: UTILITY OPERATION WARNING (DC) (INV) Label Location: Per Code: MAXIMUM POWER-_A (DC) (INV) ELECTRIC SHOCK HAZARD CEC 690.35(F) POINT CURRENT(Imp) Per Code: THE DC CONDUCTORS OF THIS MAXIMUM POWER- PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN POINT VOLTAGE(Vmp)_v CEC 690.53 UNGROUNDED AND INVERTER IS MAXIMUM SYSTEMLabel Location: MAY BE ENERGIZED v UNGROUNDED VOLTAGE(Voc) WARNING (AC) (P01) SHORT-CIRCUIT Per Code: CURRENT(Isc) A ELECTRIC SHOCK HAZARD CEC 690.17 DO NOT TOUCH TERMINALS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label Location: WARNING (DC)(CB) Per Code: ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS CEC 690.17 Label Location: TERMINALS ON BOTH LINE AND PHOTOVOLTAIC POINT OF (P01) LOAD SIDES MAY BE ENERGIZED INTERCONNECTION Per Code: IN THE OPEN POSITION WARNING:ELECTRIC SHOCK DC VOLTAGE IS HAZARD.DO NOT TOUCH CEC 690.54; CEC 690.17 ALWAYS PRESENT WHEN TERMINALS.TERMINALS ON SOLAR MODULES ARE BOTH THE LINE AND LOAD SIDE EXPOSED TO SUNLIGHT MAY BE ENERGIZED IN THE OPEN POSITION.FOR SERVICE DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. (< ,.z.y,,.,;. CUPERTINO PV POWER SOURCE 4 �! MAXIMUM AC �. Building Department Label Location: OPERATING CURRENT A (DC) (INV) MAXIMUM AC Ir -�-..� WARNING Per Code: OPERATING VOLTAGE _ V 1:-'--1 JUN I ZU� ELECTRIC SHOCK HAZARD CEC 690.5(C) IFAGROUND FAULT IS INDICATED REVIEWED FOR CODE COMPLIANCE NORMALLY GROUNDED CONDUCTORSUNEDANEMNY BE ERGIZED Reviewed By �RT UNGROUNDED AND ENERGIZED ,��s..i Label Location: CAUTION (D)(POI) Per Code: PHOTOVOLTAIC SYSTEM CEC 690.64.6.4 Label Location: CIRCUIT IS BACKFED PHOTOVOLTAIC AC (AC) (P01) (AC): Disconnect Per Code: (C)):: Conduit DISCONNECT (CB): Combiner Box CEC 690.14.C.2 Label Location: (D): Distribution Panel (DC): DC Disconnect CAUTION (P01) (IC): Interior Run Conduit DUAL POWER SOURCE Per Code: SECOND SOURCE IS CEC 690.64.B.4 (INV): Inverter With Integrated DC Disconnect PHOTOVOLTAIC SYSTEM (LC): Load Center (M): Utility Meter (P01): Point of Interconnection CONFIDENTIAL— THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR `%k44 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED gp• San Mateo,CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, SC - CA Label Set ����. o l a rC qtT:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE I' Sy (888)-SOL-CITY(765-2489)www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. o mono multi solutions Trinamount II FOR PITCHED ROOF TSM-PC05/ PA05.18 mono multi solutions ELECTRICAL DATA STC TSM-225 TSM-230 TSM-235 TSM-240 TSM-245 DIMENSIONS OF PV MODULE TSM-PCOS/PAO5.18 PC/PA05.18 PC/PA05,18 PC/PA05,18 PC/PA05.18 PC/PA05.18 Peak Power Wafts-Pwa(Wp) 225 230 235 240 245 • 1 1 O YEAR Power Output Tolerance-Pnux(%) 0/+3 0/+3 0/+3 0/+3 0/+3 Trinamount II wxc - Maximum Power Voltage-Vue(V) 29.4 29.8 30.1 30.4 30.7 PRODUCT WARRANTY FOR MODULE Maximum Power Current-Inwe(A) 7.66 7.72 7.81 7.89 7.9B TrLasolar AND MOUNTING SYSTEM Open Circuit Voltage-Voc(V) 36.9 37.0 37.1 37.2 37.3 FOR PITCHED ROOFShort Circutf Cur ent-Ix(A) f3.20 8.26 8.31 8.37 8,7 5 X Module Efficiency qm(%) 13.7 14..1 14.4 14.7 5 0 FASTER TO INSTALL AL jA ValuesoltlandardTertConNtonsSTC(AlrMerrAM1.5,Irtadiancel000W/m',CetTemperature25°C). U LT RA L 0 W ELECTRICAL DATA @ NOCT TSM-225 TSM-230 TSM-235 TSM-240 TSM-245 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 PC/PA05.18 R ESI STA N C EInISTAIINC Maximum Power)W) 164 168 72 175 178 Maximum Power Voltage)V) 26.9 27.1 27.4 27.7 27.8 e GROUND BOND CONNECTION "° Maximum Power Current(A) 6.12 6.20 6.27 6.32 6.41 10X BETTER THAN UL MINIMUM CRITERIA E Open Circuit Voltage(V) 33.8 33.9 34.0 34.1 34.2 1101F , s.°a, re' Short Circuit Current(A) 6.62 6.68 6.70 6.75 6.83 NOCT:Irradiance at 800W/m4,Ambient Temperature 20°C,Wind Speed 1M/s. '� Back View MECHANICAL DATA tt\ \' X11 N ` - • _ Solar cells Mulficrystalline 156 x 156mm(6 inches) l',.- . � _I 11 I Cell orientation 60 cells(6 x 10) ys .i °>yii '\4 °. Module dimension 1650 x 992 x 40mm(64.95 x 39.05 x 1.57 inches) i \ 1 \, x}\, Weight 20.3kg(44.8 lb) �s } �l \ \ Glass High transparency solar glass 3.2mm(0.13 inches) 1 'Z - Frame Anodized aluminium alloy r °„ J-Box IP 65 rated �,,,-- A-A Cables/Connector Photovoltaic Technology cable 4.0mm°(0.006 inches'), 1100mm(43.3 inches),MC4/H4 I-V CURVES OF PV MODULE TSM-230PC05/PA05.18 9r° 1000W/m' .._ 8`n - TEMPERATURE RATINGS 75°_e00Wlh Nominal Operating Cell 46°C(±2°C) 6. --- __ Temperature(NOCT) a' 600w/m' 5F°.-_- - _ - Temperature Coefficient of Pwx -0.43%/°C ,e -1Temperature t ,,..4CU RTIN U eoowfm' \`t -i Temperature Coefficient of of lsc t 4.0 1Building Depa rture t - _. _ ---..__-z,.,.,.- _ -3.,,�- _ sooty/m'----------------- � -y. .r 2. a - SUITABLE FOR 1. \\ll '� I COMBINING PV MODULE EXPERTISE WITH A HIGHLY D� :` :-> -tel zoo 30° 401. . , UN 7 201 INNOVATIVE MOUNTING SYSTEM SOLUTION. MAXIMUM RATINGS Vdtage(V) ENEN COMPOSITION SHINGLE Operational Temperature -40^+85°C liw Trina Solar is introducin Trinamount-the fastest,easiest and least � ��/C . • g Maximum System Voltage 10�Y-D`'iOir6UE0 OR CODE COMPLIAN expensive way to mount PV modules onto residential and commercial DC(UL) '�// g® rooftops.With a series of drop-in and quarter-turn connections on a Max Series Fuse Rating 15A Reviewer By' j;09 expensive g TRAPEZOIDAL METAL specialized module frame,this mounting solution installs up to 5 times CERTIFICATION Y faster than conventional mounting systems.Trinamount connects w <' directly to the module frame,eliminating the need for long rails. (( ISO PV`YCLE %I1 CO WARRANTY Bydrasticallyreducingthe number ofparts,cost of materials and i3 1 STANDING SEAM ROOF Li IO yearworkmanshipwarranty ao installation time,Trinamount offers the optimal solution for residential C�I�°s n_ 25 year linear performance warranty a and commercial installations. 1 (Please refer to product warranty for details) I Trinasolar Trinasolar n CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. The power behind the panel ComppS' The power behind the panel 02011 Trio Solar Limited.Al rights reserved.Specification ksckded in this datasheet are subject to change without notice. SolarCitySleekMountTM - Comp SolarCitySleekMountTM - Comp The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed \ Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules aesthetics while minimizing roof disruption and j Drill Pilot Hole of Proper Diameter for •Interlock and grounding devices in system UL labor.The elimination of visible rail ends and listed to UL 2703 Fastener Size Per NDS Section 1.1.3.2 mounting clamps, combined with the addition :R of array trim and a lower profile all contribute •Interlock and Ground Zep ETL listed to UL 1703 p p •, Seal pilot hole with roofing sealant to a more visually appealing system.SleekMount as"Grounding and Bonding System" V, • Insert Comp Mount flashing under upper utilizes Zep CompatibleTM modules with •Ground Zep UL and ETL listed to UL 467 as layer of shingle ' strengthened frames that attach directly to grounding device Place Comp Mount centered Zep Solar standoffs,effectively eliminating the 1 need for rail and reducing the number of •Painted galvanized waterproof flashing upon flashing standoffs required. In addition, composition 1 Install lag pursuant to NDS Section 11.1.3 •Anodized components for corrosion resistance shingles are not required to be cut for this with sealing washer. system,allowing for minimal roof disturbance. •Applicable for vent spanning functions _ Secure Leveling Foot to the Comp Mount 4:11I using machine Screw • Place module A Components _._ 0 5/16"Machine ScrewI <� Leveling FootJca a Lag Screw 0 et Comp Mount ''4 A 41 MI C et Comp Mount Flashing 1. I E 42, �� CUP�RTIN� .i:��l 14-00,..0 wilding De Nis 1="7 JUAN 2 7 2013 tEVIEVVEI FSR GORE COMPLIANCE Rev�e>rwed By ��s, �,yT�,,y� w`oMP4p TI. SolarCity January 2013 �q/ Ji LISTED SolarCity M PPre ® January 2013 Po` we-0118= l Renewable EnergySolutions AURORA TE.,HNICAL DATA VALUES PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI -4.2 -USC Nominal Out putPower W 3000 3600 4200 ' "' `'m"' " • -` -"�" "'-"'"'"_ Maximum Output Power W 3000 3300" 3300" 3600 4000" 4000" 4200 4600" 4600" „. Rated Grid AC Voltage V 208 240 277 208 240 277 208 240 277 Z Input Side(DC) Number of Independent MPPT Channels 2 2 2 PVI-3.0-TL Q Maximum Usable Power for Each Channel W 2000 3000 3000 OC Absolute Maximum Voltage(Vmax) V 600 600 600 Start-Up Voltage(Vstart) V 200(adj.120-350) 200(adj.120-350) 200(adj.120-350) PVI-3.6-TL Full Power MPPT Voltage Range V 160-530 120-530 140-530 Q Operating MPPT Voltage Range V 0.7xVstart-580 0.7xVstart-580 0.7uVstart-580 Maximum Current(Idcmax)for both MPPT in Parallel A 20 32 32 PVI-4.2-TL Maximum Usable Current per Channel A 10 16 16 i Maximum Short Circuit Current Limit per Channel A 12.5 20 20 Number of Wire Landing Terminals Per Channel 2Pairs(1on-S version) 2Pairs(1on-S version) 2Pairs(1on-S version) GENERAL SPECIFICATIONS Array Wiring Termination Output Side(AC) Terminal block,Pressure Clamp,AWG10-AWG4 Split- Split- Split- 0 I ii-non P MOnFIrGrid ConnectionTypa 10/2W 0/3W 10/2W 10/2W 0/3W 10/2W 10/2W 0/3W 10/2W Adjustable Voltage Range(Vmin-Vmax) V 183-228 211-264 244-304 183-228 211-264 244-304 183-228 211-264 244-304 Grid Frequency Hz 60 60 60 Adjustable Grid Frequency Range Hz 57-60.5 57-60.5 57-60.5 U,' Maximum Current(lacmax) ARMs 14.5 14.5 12 17.2 16 16 20 20 20 �` Power Factor >0.995 >0.995 >0.995 The most common residential inverter is the ideal size for an average- Total Harmonic Distortion At Rated Power % <2 <2 <2 sized family home. This family of single-phase string inverter Grid Wiring Termination Type Terminal block,Pressure Clamp,AWG10-AWG4 complements the typical number of rooftop solar panels,allowing Protection Devices Input home-owners to get the most efficient energy harvesting for the Reverse Polarity Protection Yes Yes Yes size of the property.This rugged outdoor inverter has been designed 4,24HREEPI over-Voltage Protection Type Varistor,2 breach channel Varistor,2 for each channel Varistor,2 for each channel 111111111111 PV Array Ground Fault Detection Pre start-up Riso and dynamic GEM(Requires Floating Arrays) as a completely sealed unit to withstand the harshest environmental Output , conditions. Anti-Islanding Protection Meets UL 1741/IEE1547 Meets UL 1741/IEE1547 Meets UL 1741/IEE1547 " requirements requirements requirements Over-Voltage Protection Type Varistor,2IL,-L,/L,-G) Varistor,2IL,-L,/L,-G) Varistor,2IL,-L,/L,-G) One of the key benefits of the Uno family of single-phase inverters ) Maximum AC OCPO Rating A zo zo 15 25 20 20 25 25 25 is the dual input section to process two strings with independent 1111111111111.11111M Efficiency ) Maximum Efficiency % 96.9 97 97 MPPT especially useful for rooftop installations with two different CEC Efficiency vs 96 96 96 orientations(ie East and West).The high speed MPPT offers real-time Operating Performance Stand-by Consumption WRMs <8 <8 <8 power tracking and improved energy harvesting. Night time consumption Wow <0.6 <0.6 <0.6 Communication The transformerless operation gives the highest efficiency of up to User-Interface 16 characters x 2 lines LCD display Remote Monitoring(1uR5485 incl.) AURORA-UNIVERSAL(opt.) 97.0%. The wide input voltage range makes the inverter suitable toWired Local Monitoring(1xR5485 incl.) PVI-USB-RS485_232(opt.),PVI-DESKTOP(opt.) low power installations with reduced string size. III Wireless Local Monitoring PVI-DESKTOP(opt.)with PVI-RADIOMODULE(opt.) ) Environmental Ambient Air Operating Temperature Range °F(°C) -13 to+140(-25 to+60)with -13 to+140(-25 to+60)with -13 to+140(-25 to+60)with • derating above 131(55) derating above 131(55) derating above 113(45) Ambient Air Storage Temperature Range °F(°C) -40 to 176(-40 to+80) -40 to 176(-40 to+80) -40 to 176(-40 to+80) Relative Humidity %RH 0-100 condensing 0-100 condensing 0-100 condensing Acoustic Noise Emission Level db(A)@1 m <50 <50 <50 Maximum Operating Altitude without Derating ft(m) 6560(2000) 6560(2000) 6560(2000) Mechanical Specifications Enclosure rating NEMA 4X NEMA 4X NEMA 4X • Each inverter is set on specificgrid codes which can be selected in the field Cooling Natural Convection Natural Convection Natural Convection P Dimensions(HxWxDi in(mm) 33.8012.8x8.7(859 x 325 x 222)-S Version • Single phase output Weight lb/(kg) <47.3(21.3)-S version <47.3(21.3)-S version _ _5.47,x(21.3)-S version �UPERTINO • Dual input sections with independent MPPT,allows optimal energy harvesting from two sub-arrays oriented in Mounting System wall bracket Wallbracke[ _' °'TlVallbracket Trade size KOs:(tea x 1/2")and Trade size KOs:(tea x 1/2)ar(*, T KOs:(tea x 1/2")and different directions Conduit Connections*** (2811x1-1/4;3places side,front, (2811x1-t/4;3places ndefr8 / ( .� ;3places side,frortt�Ul(djn,� papa�en( • Wide input range rear) rear) b d ' rear) DC Switch Rating(Per Contact) AN 25/600 25/600 •, .:4-!4',',-•-•! 25/600 • High speed and precise MPPT algorithm for real time power tracking and improved energy harvesting Safety >* • Flat efficiency curves ensure high efficiency at all output levels ensuring consistent and stable performance across Isolation Level Transformerless(Floating Array) Transformerless(Floating Ar ,•`-rn,.i •Hess( Floating Array) ;:t.)1 tit Safety and EMC Standard UL 1741,CSA-C22.2 N.107.1-01 UL 1741,CSA-C22.2 N.107.1-01 UL 1741,CSA-C22.2 N.107.1-01 the entire input voltage and output power range Safety Approval ,CSA,, ,CSA,,, ,,CSA • Outdoor enclosure for unrestricted use under any environmental conditions Warranty REV)EVUE . AOR CODE COMPLIANCE • Integrated DC disconnect switch in compliance with international Standards(-S Version) Standard Warranty years 10 10 10 Extended Warranty years 15&20 15&20 ,;" 8t2Q; • RS-485 communication interface(for connection to laptop or datalogger) Available Models -5.;-..^.../ ��+'J • Compatible with PVI-RADIOMODULE for wireless communication with Aurora PVI-DESKTOP Standard-Without DC Switch and Wiring Box PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-4.2-OUTD-US With DC Switch and Wiring Box PVI-3.0-OUTD-S-US PVI-3.6-0UTD-S-US PVI-4.2-OUTD-S-US 'An data is subject to change without notice "Capability enabled at nominal AC voltage and with sutbcient DC power available AURORA UNO 3 •^When equipped with optional DCSwitch and Wiring Box .tib ' ' CSA INTERNATIONAL Certificate of Compliance Certificate: 2096477 Master Contract: 173688 Project: 2439385 Date Issued: July 19,2011 Issued to: Power-One,Inc 740 Calle Plano Camarillo,CA 93012 USA Attention:Robert White The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C'and 'US'for Canada and US or with adjacent indicator 'US'for US only or without either indicator for Canada only. Rob-1feAttpstoc10 Issued by: Rob Hempstock,AScT. C US PRODUCTS CLASS 531109 -POWER SUPPLIES-Distributed Generation Power Systems Equipment CLASS 531189 -POWER SUPPLIES-Distributed Generation-Power Systems Equipment -Certified to U.S.Standards Utility Interactive Inverter,Models PVI-4.2-OUTD-US,PVI-3.6-OUTD-US,PVI-3.0-OUTD-US,PVI-4.2- OUTD-S-US,PVI-3.6-OUTD-S-US,PVI-3.0-OUTD-S-US,PVI-4.2-OUTD-US-W,PVI-3.6-OUTD-US-W and PVI-3.0-OUTD-US-W;provided with two DC input channels,permanently connected. For details related to ratings,reference should be made to the CSA Certification Record,Appendix 1 or the Descriptive Report. v! CUPERTINO APPLICABLE REQUIREMENTS Building Department CSA-C22.2 No.107.1-01 - General Use Power Supplies i \ p p aa�� qq 3 UL Std No. 1741-Second Edition - Inverters,Converters,Controllers and Interconnection System Equipment1�1 for Use With Distributed Energy Resources(January 28,2010) REV:i;EV'VED FOR CODE COMPLIANCE Reviewed By. L.:5werA DQD 507 Rev.2009-09-01 Page:1 Intertek AUTHORIZATION TO MARK Intertek AUTHORIZATION TO MARK r__._ ,, T This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing i TSM-200PA05,TSM-205PA05,TSM-210PA05,TSM-215PA05,TSM-220PA05,TSM-225PA05,TSM- Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing ' 230PA05,TSM-235PA05,TSM-240PA05,TSM-245PA05 and TSM-250PA05. Report. TSM-200PA05.05,TSM-205PA05.05,TSM-210PA05.05,TSM-215PA05.05,TSM-220PA05.05,TSM- This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be 225PA05.05,TSM-230PA05.05,TSM-235PA05.05,TSM-240PA05.05,TSM-245PA05.05 and TSM- applied only at the location of the Party Authorized To Apply Mark. 250PA05.05. Applicant: Trina Solar Ltd Manufacturer: Changzhou Trina Solar Energy Co.,Ltd. TSM-200PA05.10,TSM-205PA05.10,TSM-210PA05.10,TSM-215PA05.10,TSM-220PA05.10,TSM- 225PA05.10,TSM-230PA05.10,TSM-235PA05.10,TSM-240PA05.10,TSM-245PA05.10 and TSM- Address: No.2 Tian He Road,Electronic Park, Address: No.2 Tian He Road,Electronic Park, 250PA05.10. New District,Changzhou,Jiangsu New District,Changzhou,Jiangsu TSM-200PA05.15,TSM-205PA05.15,TSM-210PA05.15,TSM-215PA05.15, Country: China Country: China Models: TSM-220PA05.15,TSM-225PA05.15,TSM-230PA05.15,TSM-235PA05.15, Contact: Ms.Lihua Yin Contact: Ms.Lihua Yin TSM-240PA05.15,TSM-245PA05.15 and TSM-250PA05.15. Phone: +8651968879039 Phone: +8651968879039 FAX: +8651968879006 FAX: +8651968879006 TSM-200PA05.18,TSM-205PA05.18,TSM-210PA05.18,TSM-215PA05.18, Email: Iihua.yin@trinasolar.com Email: lihua.yin@trinasolar.com TSM-220PA05.18,TSM-225PA05.18,TSM-230PA05.18,TSM-235PA05.18, Party Authorized To Apply Mark: Same as Manufacturer TSM-240PA05.18,TSM-245PA05.18 and TSM-250PA05.18. Report Issuing Office: Menlo Park,CA,USA GO TSM-155DA01,TSM-16ODA01,TSM-165DA01,TSM-17ODA01,TSM-175DA01, Control Number: 4003042 Authorized by: C/Qi TSM-180DA01,and TSM-185DA01. illiam T.St rr,Certification Manager ) TSM-155DA01.05,TSM-160DA01.05,TSM-165DA01.05,TSM-170DA01.05, TSM-175DA01.05,TSM-180DA01.05,and TSM-185DA01.05. C US• �aw Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to Mark Is for the exclusive use of intertek's Client and Is provided pursuant to the Certification agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only In Its entirety.Use of intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to Mark.Any further use of the intertek name for the sale or advertisement of the tested material,product or service must first be approved in writing by intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations In this respect. Intertek Testing Services NA Inc. 165 Main Street,Cortland,NY 13045 Telephone 800-345-3851 or 607-753-6711 Fax 607-756-6699 Standard for Flat-Plate Photovoltaic Modules and Panels UL 1703-Third Edition,March 15,2002,with revisions through May 23,2011 ,, ;. CUPERTINO Standard(s): Building Department Requirements for Flat-Plate Photovoltaic Modules and Panels,ULC/ORD-C1703-01-First Edition, ��! t ammended October 2001 ` a Product: Flat Plate Photovoltaic Modules - :h..: Brand Name: Trina Solar REVIEWED FOR CODE COMPLIANCE/ 5 Reviewed By: a zv /174-‘-171 ATM for Report SH11031298-001 Page 1 of 2 ATM Issued: 19-Jul-2011 ATM for Report SH11031298-001 Page 2 oft ATM Issued: 19-Jul-2011 ED 8.9.4(8-Jan-10)Mandatory ED 8.9.4(8-Jan-10)Mandatory