Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
13110134
CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 10049 OAKLEAF PL CONTRACTOR:A&H HEATING PERMIT NO:13110134 OWNER'S NAME: WEHRLY JAMES E AND REBA J TRUS 770 CHESTNUT ST DATE ISSUED: 11/20/2013 OWNER'S PHONE: 6504649523 SAN JOSE,CA 95110 PHONE NO:(408)279-0722 ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION: RESIDENTIAL 0 COMMERCIAL11 License Class Z0 Li..# 30`147 REMOVE AND REPLACE(2)FURNACE&(2)A/C LOCATED ONContractor �(�' l lit C� Date 1(` ?10 a SIDE OF SFDWL I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$14000 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:32618054.00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 0 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAY F M LAST CALLED INSPECTION. indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the Issued by: Date: granting of this permit. Additionally,.the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section 9.18. q_ �j RE-ROOFS: Signature Dgte l (�cif/ 1✓ All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. ❑ OWNER-BUILDER DECLARATION I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: Date: the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,S����%ate: Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized agent: permit is issued. I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to.become subject to the Worker's Compensation laws of California. If,after making this certificate of exemption,I CONSTRUCTION LENDING AGENCY become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9.18. Signature Date GENERAL PERMIT APPLICATION MEP COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 `00� misc CUiP RTINO (408)777-3228•FAX(408)777-3333•building a0cupertino.org ❑PLUMBING ❑MECHANICAL ❑ELECTRICAL [:]MISCELLANEOUS PROJECT ADDRESS 1 ( H Lf f O7 0)/L r,- r,��!�e 'F�' APN# � 16 O OWNERNAME'�r A LI - 11 ` V`� PHO /_5 1 - ?527 EMAII /J I. N STREET ADDRESS(V ® !✓ (/ !`1 n ®/ FAX CONTACT NAME L✓ ✓ P O© tea 722- AW 1 STREETADDRESS 7 70 .F 57W - C CITY,ST9E, F -}=- �� �/f 7 FAX/J�xQ ❑O� '❑ OWNER-BUIIAER ❑ OwNERAGENT CONTRACTOR ❑CONTRACTOR AGENT ❑ ARCHITECT 1:1 ENGINEER ❑l(DDEEjVEELLOPEERR ❑TENANT CO CTR w LICENSENUMBER LICENSE TYPE/3( BUS.LIC# COM PA -7 ei• /� ✓' E-MAIL AX v STREET ADDRESX 7r CITY,STAT ZI PHO LL�!C (� ARCHITECT/ENGINEER,NAME LICENSE NUMBER BUS.LIC# COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF ACSFD or DUPLEX ❑ MULTI-FAMILY PROJECT IN WIIALAND ❑ YES PROJECT IN ❑YES IS THE BLDG AN ❑YES BUILDING: ❑COMMERCJAL URBAN.INTERFACERREA ❑ NO FLOOD ZONE ❑NO EICHLER HOME? ❑NO DESCRIPTION OF WORK G Z TOTAL VALUATION: -- k By my signature below,I certify to each of the following: I am the property owner or authorized agent to act n eoperty o have read this application and the information I have provided is.correct. I have read the Description of Work and verify it s acc te. I ee to comply with all applicable local ordinances and state laws relating to building construction. I uthorize representatives of Cupertino to enter the A entified property for inspection purposes. Signature of Applicant/Agent: Date: SUPPLEMENTAL INFORMATION REQUIREDoCE us> oly - 1 w RUM . — " - ` 4 d n MEPMiscApp_2011.doc revised 06121111 CITY OF CUPERTINO FEE ESTIMATOR-BUILDING DIVISION lag ADDRESS: 10049 oakleaf pl DATE: 11/20/2013 REVIEWED BY: mendez APN: BP#: *VALUATION: 1$14,000 -1 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration/ Repair PRIMARY SFD or Duplex PENTAMATION FURN/AC USE: PERMIT TYPE: WORK remove and replace(2)furnace & 2 a/c located on side of sfdwl SCOPE s,si ' esx - $ �` Xa K rh RM We Mech.Plan Check "00 $0.00 .Plumb.Plan Check Elec.flan Check Mech.Permit Fee: IMPERMIT Plumh.Permit Pee: Elec. Permit Pee: Other Mech.Insp. 0.0 hrs $47.00 ether Plumb Insp. ELI Other Elec.Insp. A1ech.Imp. Fee: Plumb. Insp.Fee: Elec.Insp.Fee: NOTE:This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,eta). Thesefees are based on the prelimina information available and are only an estimate. Contact the De t or addn'1 info. FEE ITEMS (Fee Resolution 11-053 Ef. 7/1/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 = # Mechanical Suppl.PC Fee: (E) Reg. .® OT 0.0 1 hrs $0.00 $278.00 IMFR=<Io0 I Furnace,Forced-Air PME Plan Check: $0.00 LLJ # Mechanical Permit Fee: $0.00 $140.00 IBREivmm A/C Units(<=1OK cfm) Suppl. Insp.Feer Reg. ® OT ' 0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $47.00 (,onstyztction Tax: Administrative Fee: IADMIN $44.00 0 Work Without Permit? ®Yes 0 No $0.00 G Advanced Planning Fee: $0.00 Select a Non-Residential 0 Travel Documentation Fee: ITRAVDOC $47.00 Building or Structure i Strong Motion Fee: IBSEISMICR $1.40 Select an Administrative Item Blda Stds Commission Fee: IBCBSC $1.00 $140.40 $418.00 � . Q � . 558.40 Revised: 10/01/2013 HVAC ALTERATIONS ENERGY COMPLIANCE FORM COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION ALBERT SALVADOR, P.E., C.B.O., BUILDING OFFICIAL CUPERT[N.0 10300 TORRE AVENUE-CUPERTINO, CA 95014-3255 (408)777-3228-FAX(408)777-3333-building5cupertino.or4 WHEN IS A PERMIT REQUIRED A construction permit shall be obtained from the enforcement agency prior to the erection, construction, reconstruction, installation,relocation, or alteration of any mechanical system, except as permitted in Chapter 1, Section 112.2 of the 2010 California Mechanical Code. Projects requiring permits include, but are not limited to: • New HVAC installation • HVAC Changeout • Replacement of furnace, coil,FAU or condenser • Relocation of an existing HVAC unit • Adding or replacing more than 40ft ducting in unconditioned space BUSINESS AND PROFESSIONS CODE, SECTION 7110 Willful or deliberate disregard and violation of the building laws, including the California Building Code, and local permit requirements constitutes a cause for disciplinary action from the Contractors State License Board working in conjunction with the local building department. This action may consist of fines up to $5,000 per violation or suspension/revocation of a contractor's license. 2008 BUILDING ENERGY EFFICIENCY STANDARDS (Title 24,Part 6)REQUIREMENTS INCLUDE: 1. Heating equipment must have a minimum 78%AFUE(Exception: Wall &floor furnaces; room heaters). 2. Central air conditioners &heat pumps less than 65,000 Btu/hr must have a minimum 13 SEER. 3. Newly installed or replaced ducts must have a minimum insulation value of R-4.2. 4. A setback type thermostat(24 hr clock with four set points) is required for all alterations. 5. New or replacement ducts must meet the mandatory requirement of Section 150(m). • All joints and openings in the HVAC system must be sealed. • Only UL 181, UL 181A, or UL 181B approved tapes or mastic shall be used to seal duct openings. • Connections of metal ducts and the inner core of flex ducts shall.be mechanically fastened. Flex ducts must be connected using a metal sleeve/coupling. • Flex ducts that are suspended must be supported every 4 ft. max for horizontal runs with no more than 2"of sag between supports and 6 ft. max for vertical runs. 6. The CF-6R-MECH-04 must be completed and signed by the installing contractor. The Inspector will collect this form and verify that the model numbers are the same as the installed equipment. 2008 Residential Compliance Forms.doc revised 04/10/12 amplified Prescriptive Certificate of Compliance:2008 ResidenthdRVACAlterationIs CF-ZR-ALT-HV ke Climate Zona 1 sad 3-7 Mte.4ddress En orcement�4 Ilrrii _ Permit CoAtioned Duct tnsiilation eat Type' hist r.Cini iLn floor T hii stat Unit erldmged Over 44 8 of ducts" urisace AFUE COP Setback Served'by system aided or replaced in Indoor Coif [35� HSPI rmconditioaed space 8rivI,dr—dypreseu musttw t�U ; Condensing Unit ®EER E3 Resist . sf' ®1Z 6 (CZ I,3-5) E3 other I • 1.Equipment Type:Goose the equipment being installed;if more than one system,use another CF-IR-ALT HVAC.for each system. 2.Afinimuia Equipment Efficiencies:13 SEER,78%AFUE,7.7HSPF for typical residential systems. Contractor(Documentation Author's/Responsible Designer's Declaration Statement) • I=tYy that this Certificate of Compliance documentation is accurate and complete. • I am eligible under Division 3 of the California Business and Professions Code to accept:esponsibility for the design identified m this Certificate of Compliance. • I certify that the energy features and perfoinance specifications for the design identified on this Certificate of Compliance conform to the requirements of Title 24,Parts I and 6 of the California Code of Regulations. • The design features identified on this Certificate of Compliance are consistent with the infonnation documented on other applicable compliance foams,worksheets,calculations,plans and specifications submitted to the enN-cement agency for approval with the pen-nit licafioa. Name: /L Signature: 7 Company: r 7-11 h- Addreso o< D Address-, c�T.: IT .--; /�� City/StatetZip: � . Phone: 2008 Residential Compliance Forms.doc revised 04/10/12 HVAC ALTERATIONS ENERGY COMPLIANCE FORM COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION ALBERT SALVADOR, P.E., C.B.O., BUILDING OFFICIAL CUPERTIN. 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 (408)777-3228•FAX(408)777-3333•building<aDcupertino.org WHEN IS A PERMIT REQUIRED A construction permit shall be obtained from the enforcement agency prior to the erection, construction, reconstruction, installation,relocation, or alteration of any mechanical system, except as permitted in Chapter 1, Section.112.2 of the 2010 California Mechanical Code. Projects requiring permits include, but are not limited to: • New HVAC installation • HVAC Changeout • Replacement of furnace, coil,FAU or condenser • Relocation of an existing HVAC unit • Adding or replacing more than 40ft ducting in unconditioned space BUSINESS AND PROFESSIONS CODE, SECTION 7110 Willful or deliberate disregard and violation of the building laws, including the California Building Code, and local permit requirements constitutes a cause for disciplinary action from the Contractors State License Board working in conjunction with the local building department. This action may consist of fines up to $5,000 per violation or suspension/revocation of a contractor's license. 2008 BUILDING ENERGY EFFICIENCY STANDARDS (Title 24,Part 6) REQUIREMENTS INCLUDE: 1. Heating equipment must have a minimum 78%AFUE(Exception: Wall &floor furnaces; room heaters). 2. Central air conditioners&heat pumps less than 65,000 Btu/hr must have a minimum 13 SEER. 3. Newly installed or replaced ducts must have a minimum insulation value of R-4.2. 4. A setback type thermostat(24 hr clock with four set points) is required for all alterations. 5. New or replacement ducts must meet the mandatory requirement of Section 150(m). • All joints and openings in the HVAC system must be sealed. • Only UL 181, UL 181A, or UL 181B approved tapes or mastic shall be used to seal duct openings. • Connections of metal ducts and the inner core of flex ducts shall.be mechanically fastened. Flex ducts must be connected using a metal sleeve/coupling. • Flex ducts that are suspended must be supported every 4 ft. max for horizontal runs with no more than 2"of sag between supports and 6 ft. max for vertical runs. 6. The CF-6R-MECH-04 must be completed and signed by the installing contractor. The Inspector will collect this form and verify that the model numbers are the same as the installed equipment. 2008 Residential Compliance Forms.doc revised 04/10/12 Simplified Prescriptive Certificate of Compliance:2008 Residential$YACAlterations CF-IR-ALT-HVAC Climate Zones 1 stud 3-7 ML- © 'C l �nforcerner 20-yCZ�` /— Dare 6 q Permit il:. 'oned Duct insolation ElmlipmentTypelU's hlmiai#m Ef icier Floor Area re Thermosfat >.� 13 Packaged Unitover O fi of ducts' Furnace k �° ®COP Served system ` added or replaced in c Setba Indoor Cot? ' SIEEk HSPF sf' unconditioned space (If nor alreadypre"A M*sf be Condensing Unit ®EER Resistance E3 R 6 (CZ 1,3-5) Other 1.Equipment Type:Choose the equipment being installed;if more than one-system,use another CF-IR-ALT-HVAC for each system. 2.A(mimum Equipment Efficiencies-13 SEER,78%AFUF,7.7HSPF for typical residential systems. Contractor(IMcumentation Author's/Responsible Designer's Declaration Statement) • I certify that this Certificate of Compliance documentation is accurate and complete. • I am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the design identified on this Certificate of Compliance. • I certify that the energy features and performance specifications for the design identified on this Certificate of Compliance conform to the requirements of Title 24,Parts I and 6 of the California Code of Regulations. • The design features identified on this Certificate of Compliance are consistent with the infomtation documented on other applicable compliance forms,worksheets,calculations,plans and specifications submitted to the enforcement agency for approval with the permit application, _ Name: Signature: ` �7 Company Date Address: License: c9 L-f r City/State/Zip: Phtone: Lf�rd �71�I_d7Z 2008 Residential Compliance Forms.doc revised 04110112 `t Cy �o 0*-(-/ N I G i 4 �tC 3► PLOT PLANS C) ECKED: BY DW Lil Q T DEPT. f— WQ MUST h9k-m+pt 04 rt U ® U. �1 CV d.i rldi, �1�� w ,��a u� � `"lel� a O C14 'J p;,m and specifications SHALL NOT 0Y m CD �. 'jr to ti1E;w approval of thc-violation U:&i°y P,'c' i6ions of any City Ordinance or State Law. Cti� BY _-yes �V l G �— - ... .: N PEi=ii',rllT NO.�J 3)I b( W