Loading...
14020121 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 18630 RUNO CT CONTRACTOR:SOLARCITY PERMIT NO: 14020121 OWNER'S NAME: PETER&DAISY YOH 3055 CLEARVIEW WAY DATE ISSUED:02/21/2014 OWNER'S PHONE: SAN MATEO,CA 94402 PHONE NO•(650)638-1028 ❑ LICENSED CONTRACTOR'S DECLARATION� ( BUILDING PERMIT INFO• BLDG ELECT PLUMB License Class C, C- Lic.# (O a ("I MECH RESIDENTIAL COMMERCIAL c Contractor sckc t Date ISL /3( 1"I Cf I hereby affirm that I am licensed under the provisions of Chapter 9 JOB DESCRIPTION INSTALL ROOFTOP SOLAR 3 75 KW 15 PANELS (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$15000 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. APN Number:37525032.00 Occupancy Type: APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating PERMIT EXPIRES IF WORK IS NOT STARTED to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save WITHIN 180 DAYS OF PE IT ISSUANCE OR indemnify and keep harmless the City of Cupertino against liabilities,judgments, 180 DAY FROM LAST LED INSPECTION. costs,and expenses which may accrue against said City in consequence of the granting of this permit. Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Issued by: Date: 9 18. /„( Signature Date e52-12-f(W t 2 It. I RE-ROOFS: ❑ OWNER-BUILDER DECLARATION All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for I hereby affirm that I am exempt from the Contractor's License Law for one of inspection. the following two reasons: I,as owner of the property,or my employees with wages as their sole compensation, Signature of Applicant: Date: will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER construct the project(Sec.7044,Business&Professions Code). I hereby affirm under penalty of perjury one of the following three HAZARDOUS MATERIALS DISCLOSURE declarations: I have read the hazardous materials requirements under Chapter 6.95 of the I have and will maintain a Certificate of Consent to self-insure for Worker's California Health&Safety Code,Sections 25505,25533,and 25534. I will maintain Compensation,as provided for by Section 3700 of the Labor Code,for the compliance with the Cupertino Municipal Code,Chapter 9.12 and the Health& performance of the work for which this permit is issued. Safety Code,Section 25532(a)should I store or handle hazardous material. I have and will maintain Worker's Compensation Insurance,as provided for by Additionally,should I use equipment or devices which emit hazardous air Section 3700 of the Labor Code,for the performance of the work for which this contaminants as defined by the Bay Area Air Quality Management District I will permit is issued. maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the Health&Safety Code,Sections 25505,25533,and 25534. I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's Or •r,-r authorized agent: ,' f/tf Compensation laws of California. If,after making this certificate of exemption,I i,y • Date:mial become subject to the Worker's Compensation provisions of the Labor Code,I must forthwith comply with such provisions or this permit shall be deemed revoked. CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's APPLICANT CERTIFICATION for which this permit is issued(Sec.3097,Civ C.) I certify that I have read this application and state that the above information is Lender's Name correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter Lender's Address upon the above mentioned property for inspection purposes.(We)agree to save indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the ARCHITECT'S DECLARATION granting of this permit.Additionally,the applicant understands and will comply I understand my plans shall be used as public records. with all non-point source regulations per the Cupertino Municipal Code,Section 9 18. Licensed Professional Signatur Date©?ir'4 It v2. 0CZ( ALTERNATIVE ENERGY PERMIT APPLICATION AE rill& COMMUNITY DEVELOPMENT DEPARTMENT• BUILDING DIVISION 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 (408) 777-3228• FAX(408)777-3333•buildinq a(�cupertino.orq CUPERTINO PROJECT ADDRESS /y‘ rn. 00 �� APN# ..,". 21 / • ?t.- 03.2 OWNER NAM / yo PHONE-_ �Ce+7-R6E-MAIL y t x. vicvr ci7 e,LOMOST E STREET ADDRESS1 �( ) es-606 0.71-,0.71-, C 9 CITY, STATE,ZIP cA 146"--4_ JE)(IcA- 'T(O`/141 •FVAXi�-IG. CONTACT NAME PHONE E- IAIL-�(�,,, STREET ADDRESS - TY,STATE. ZIP FAX Fe--7-este- ��/t✓/JCef�'(� h �l-eLfb ❑ OWNER 0 OWNER-BUILDER 0 OWNER AGENT u CONTRACTOR El CONTRACTOR AGENT 0 ARCHITECT 0 ENGINEER ❑ DEVELOPER 0 TENANT CONTRACTOR NAME LICENSE NUMBELICENSE TYPE_ BUS.LIC# CstCAM.--q 3`C�7"AOtJCS - 6�f�lo4 ciDrLES _ COMPANY NAMEE-MAIL FAX ,„,..c� �z STREET ADDRESSZei f 0n C f� ,l 4 CITY,$TATE ZIPC 0 J/Q CIL(c(®(f PHOo__ r, 03 Le 2 ARCHITECT/ENGINEER NAME . `- j`( LICENSE NUMBER CYIi BUS.LIC# �`�= COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF IlLeep or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE 0 Commercial URBAN INTERFACE AREA 0 Yes 0 No FLOOD ZONE 0 Yes 0 No SOLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING El OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: 5 KILOWATTS: TOTAL VALUATION:/S o ^CJ „1 ` � DESCRIPTION OF WORK v t N S'k i;S �Dp .f & - r( a N 1 e Q SOcit 2_ Pry&L . 3 : _RECEIVE BY By my signature below,I certify to each of the following: I am the property owner or authorized agent to act on the property owner's behalf. I have read this application and the information I have provide._.is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relatin: o.4' g construction. I authorize representatives of Cupertino to enter the above-ientifie�property for inspection purposes. Signature of Applicant/Agent:�Q Z Date: 0 al IL( SUPPLEMENTAL INFORMATION REQUIRED • OFFICE USE ONLY 0 OVER-THE-COUNTER P., r F- - ❑ EXPRESS U E 0. STANDARD. U .Z. 0` LARGE --0 MAJOR 4 PVApp_2012.doc revised 06/20/12 CITY OF CUPERTINO ► FEE ESTIMATOR—BUILDING DIVISION ( ADDRESS: 18830 Runo DATE: 02/21/2014 REVIEWED BY: larrys °a `'• APN: BP#: *VALUATION: $15,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition PRIMARY PENTAMATION USE: SFD or Duplex PERMIT TYPE: SOLAR-RES WORK install rooftop solar 3.75 kw , 15 panels SCOPE 1 � ' I uE, Pl'Itch. Plan Chu is I I f ie�r. f' /,7( :ck 1rc,"'t r' Wait Fee: Ph rrth. P‘,mit )r':� l:E i'h ,z;.°_. Omer-I'fum7:Inv, pi I — ic°cII — 1i,,;f3. I ee: Lie, Inv) i ( NOTE: This estimate does not include fees due to other Departments(i.e.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc.). These fees are based on the preliminary information available and are only an estimate. Contact the Dept for addn'l info. FEE ITEMS (Fee Resolution 11-053 Et 7/1/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 1 # Alternative Energy System Suppl. PC Fee: 0 Reg. 0 OT 0.0 hrs $0.00 $229.00 1PHOTOVRES Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Feer Reg. 0 OT 0.0 hrs $0.00 PME U it Fee: $0.00 PME Permit Fee: $0.00 ii(rum ei(11211111.“I'a(Iv ICI' 0 Work Without Permit? 0 Yes 0 No $0.00 Advanced Planning Fee: $0.00 Select a Non-Residential 0 Building or Structure 0 71C/vt4 )oc lrzel�Irf'r�rl 1'�',E'b': Strong Motion Fee: 1BSEISMICR $1.50 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 ® x $2.50 $229.00 TOTAL FEE: $231.50 Revised: 01/15/2014 ABBREVIATIONS ELECTRICAL NOTES JURISDICTION NOTES A AMPERE 1. WHERE ALL TERMINALS OF THE DISCONNECTING FLASHING WILL BE PAINTED TO MATCH EXTERIOR AC ALTERNATING CURRENT MEANS MAY BE ENERGIZED IN THE OPEN POSITION, BLDG BUILDING A SIGN WILL BE PROVIDED WARNING OF THE CONC CONCRETE HAZARDS PER ART. 690.17. COMMUNITY DEV r' M,!'NT DEPARTMENT) DC DIRECT CURRENT 2. EACH UNGROUNDED CONDUCTOR OF THE BUILDING DivI-fc:)N—`CUTERi!NO EGC EQUIPMENT GROUNDING CONDUCTOR MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY A An {,aV -'� (E) EXISTING PHASE AND SYSTEM PER ART. 210.5. EMT ELECTRICAL METALLIC TUBING 3. A NATIONALLY-RECOGNIZED TESTING Thi:,s.,...4 of plans and speci`ic:a::ians MUST he kept at the GALV GALVANIZED LABORATORY SHALL LIST ALL EQUIPMENT INi, c 3r,:atru r.)n. It.is unl�,kV;JI tom -e any GEC GROUNDING ELECTRODE CONDUCTOR COMPLIANCE WITH ART. 110.3. ict a C i,s a a,:eru ;i ls on i:;ta18,Or is(. ' 4. CIRCUITS OVER 250V TO GROUND SHALL cv.�i •Fran.t;ra Euiid 11 v�ilcial. t 5 �_ GND GROUND th{ ��,� ,;r'n,u4�ii"laUt�p,.� ,� HDG HOT DIPPED GALVANIZED COMPLY WITH ART. 250.97, 250.92(B) SH t_L",TOT �' '� � y Ti "� r�C^.!Sl t'F'll iill$p1�1 r..!l S '. !�Ir r tlnrl� ul I CURRENT 5. DC CONDUCTORS EITHER DO NOT ENTER Y;it arty n �, I at t' \t',...,1"-;o11-1°T ` , ,`'`�,i G#� t Imp CURRENT AT MAX POWER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR U` r' t Isc SHORT CIRCUIT CURRENT ENCLOSURES TO THE FIRST ACCESSIBLE DC o:U :i ; ,of!ill/C Cy �r` ' nC3 or,.'-,,,,';.o t_ :uv. 1 Yi,;: kVA KILOVOLT AMPERE DISCONNECTING MEANS PER ART. 690,31(E). / OA� , �� -� kW KILOWATT 6. ALL WIRES SHALL BE PROVIDED WITH STRAINBY � A� LBW LOAD BEARING WALL RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY D^;T" � ; MIN MINIMUM UL LISTING. PERMIT NO. _ `�""®1'•�•��j ` ""'"" (N) NEW 7. MODULE FRAMES SHALL BE GROUNDED AT THE m rPATE 001 NEUT TTLSCALE MANUFACTURAL UL-LISTED LOERATION USING ULPROLISTED GROUNDING $L' ' . IDED BY THE , NTSNOT TO OC ON CENTER HARDWARE. PL PROPERTY LINE 8. MODULE FRAMES, RAIL, AND POSTS SHALL BE CUPERTINO P01 POINT OF INTERCONNECTION BONDED WITH EQUIPMENT GROUND CONDUCTORS AND ., OFFICE COPY PV PHOTOVOLTAIC GROUNDED AT THE MAIN ELECTRIC PANEL. .-.ltt.71Building Department SCH SCHEDULE 9. THE DC GROUNDING ELECTRODE CONDUCTOR ... .r> SS STAINLESS STEEL SHALL BE SIZED ACCORDING TO ART. 250.166(B) & �� `�: `�"',� FEB 21 2014 STC STANDARD TESTING CONDITIONS 690.47. ``li' TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY REVIEWED FOR CODE COMPLIANC• E V VOLT Reviewed By. l+(' SS ' ' Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT VICINITY MAP INDEX 3R NEMA 3R, RAINTIGHT ' ` '_ 9,.J & _ PV1 COVER SHEET PV2 SITE PLAN c / - . PV3 STRUCTURAL VIEWS �)i' PV4 UPLIFT CALCULATIONS LICENSE GENERAL NOTES ''v,� PV5 THREE LINE DIAGRAM 0 rs, Cutsheets Attached CA # 888104 1. THIS SYSTEM IS GRID-INTERTIED VIA Af C-10 UL-LISTED POWER-CONDITIONING INVERTER. -- , 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. , ,_ 3. SOLAR MOUNTING FRAMES ARE TO BE ¢ v.J GROUNDED. 1 - .-- 4. ALL WORK TO BE DONE TO THE 2013 . -°- . , s 4 1, - MODULE GROUNDING METHOD: ZEP SOLAR CALIFORNIA BUILDING CODE AND THE 2013 II CALIFORNIA RESIDENTIAL CODE. - : ? REV BY DATE COMMENTS AHJ: Cupertino 5. ALL ELECTRICAL WORK SHALL COMPLY WITH , , �� IMZIEM©©2/20/2014 COMMENTS THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY _ f . THE 2013 CALIFORNIA ELECTRIC CODE. :. Pacific Gas and Electric Company .. , r m * * UTILITY: P y r Di- x4.0. . :Geo o ci i c al Survey' US!•` :Farm Ser- rice Aciencv ©©© CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J3-9502675 00 PREMISE OWNER: DESCRIPTION: DESIGN: Itik �CONTAINED SHALL NOT BE USED FOR THE YOH, DAISY YOH RESIDENCE Armand DeBose So�arC•BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 18630 RUNO CT 3.75 KW PV Array , PART TO OTHERS OUTSIDE THE RECIPIENT'S MODULES: CUPERTINO, CA 95014 / ORGANIZATION,EXCEPT IN CONNECTION WITHr��i�'i.� 3055 Gearview Way THE SALE AND USE OF THE RESPECTIVE (15) Advantage Module PAGE NAME: SHEEL REV: DALE San Mateo,CA 94402W SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE ; SE3800A-US-ZB-U (408) 828-7968 COVER SHEET PV 1 2/20/2014 (888)—SOL—CITY(765-2489)www.solarcity.com PITCH: 23 ARRAY PITCH:23 MP1 AZIMUTH:270 ARRAY AZIMUTH:270 MATERIAL: Low Profile W-Tile STORY: 2 Stories 18630 Runo Ct (E)DRIVEWAY Front Of House \/ O ::: CUPERTINO12014° • o U-LockoedGatedR: • BuildingFEB2Departmentcm LEGEND CID . REVIEWED FOR CODECCOMPLIANCE ® (E) UTILITY METER & WARNING LABEL o Reviewed By: _ ,O4111Ciq 0 INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS ,,,i( 16,„,i( 16, 0 o 0 o II I o IDC LLDC DISCONNECT & WARNING LABELS 2m AC o 0 Pitch 1—'—IAC DISCONNECT & WARNING LABELS . /(1i p / O DC JUNCTION/COMBINER BOX & LABELS o • 0 / m / a 0° DISTRIBUTION PANEL & LABELS / o •// (E) PV SYSTEM LC LOAD CENTER & WARNING LABELS / / O / M DEDICATED PV SYSTEM METER N. .••••• CONDUIT RUN ON EXTERIOR —...se CONDUIT RUN ON INTERIOR — GATE/FENCE r ��,. ..-1`� INTERIOR EQUIPMENT L. SITE PLAN N TOTAL ARRAY AREA (SF): 270 Scale: 3/32” = 1' �+ TOTAL ROOF AREA (SF): 2330 w NorE TOTAL ARRAY AREA IS a 11.57 01' 10' 21' PERCENT OF TOTAL ROOF AREA 1,1.,/, / /,/ ,/ ��//,f.,; �� S CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-9502675 00 PREMISE OWNER: DESCRIPTION: DESIGN: \�,. ■ CONTAINED SHALL NOT BE USED FOR THE YOH, DAISY YOH RESIDENCE Armand DeBose ,,,So�arCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: 4„ NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 18630 RUNG/QCT 3.75 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES CUPERTINO, A 95014 ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (15) Advantage Module SHEET: REV: DALE San Mateo,CA 94.402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: NAME:INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE3800A—US—ZB—U (408) 828-7968 SITE PLAN PV 2 2/20/2014 (688)-SOL-CITY(765-2489)www.solarcity.com (E) 2x3 , e .„...,. . ---- iiiii .. /1'-6' 5'-7" /-3'-5" / 4'-7" / 4'-8" / , (E) LBW A SIDE VIEW OF MP1 NTS MP1 X-SPACING X-CANTILEVER Y-SPACING Y-CANTILEVER NOTES LANDSCAPE 72" 24" 52" 24" PORTRAIT 48" 20" 52" 24" „ ROOF AZI 270 PITCH 23 '' ' ` �'Y0 L>s r E R t I v O RAFTER: 2x4 @ 24 OC ARRAY AZI 270 PITCH 23 STORIES: 2 , C.J.: 2x4 @24"OC Low Profile W-Tile P, Building Department cam° "'`.� FEB 21 2014 REVIEWED FOR CODE COMPLIANCE INSTALLATION ORDER Reviewed By f J9 ZEP SPANNER BAR LOCATE RAFTER, MARK RAFTER (6) LOCATION, AND REMOVE TILE. (1) PLACE STANDOFF BASE & DRILL ii _ -,, ____ PILOT HOLES AT THE RAFTER /1411111= Aft2 _�_ LOCATION. g" DIA BOLT & NUT (7) (3) 2) CLEAN PAPER AROUND PILOT HOLE. ZEP SPANNER i� ��I�� „ /�■ BAR CLAMP =7T _a 1,l� _ ` = (1,‘ ADJUST STANDOFF HF.TO BATTEN STANDOFF - (E) TILE SEAL PILOT HOLES AND BOTTOM V 0 U (4) OF STANDOFF WITH POLYURETHANE (E) ROOF DECKING (5) (4) SEALANT. 5/16" DIA LAG BOLT 5) LAG STANDOFF INTO RAFTER. (2-1/2" EMBED, MIN) LOWEST MODULE SUBSEQUENT MODULES (E) RAFTER 6) NOTCH TILE WEATHERING TO FIT STANDOFF AROUND STANDOFF. O Scale: 1 1/2" = 1' 0REINSTALL TILE. CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J B-9502675 0 o PREMISE OWNER: DESCRIPnON: DESIGN: �\k4� ■ CONTAINED SHALL NOT BE USED FOR THE YOH, DAISY YOH RESIDENCE Armand DeBose �''" 1�SoIOI . I y BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 18630 RUNG CT 3.75 ION PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES C U P E R TI N 0 CA 9 501 4 - ORGANIZATION, EXCEPT IN CONNECTION WITH 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (15) Advantage Module SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME SHEET: REV: DATE: San Mateo,CA 94402 INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE3800A—US—ZB—U (408) 828-7968 STRUCTURAL VIEWS PV 3 2/20/2014 (888)-SOL-CITY(765-2489)www.solarcity.com UPLIFT CALCULATIONS 02.20.2014 �`.;.,, olarCit�� SleekMountTM PV System Version#27.9 Structural Desian Software Project information&Table Of Contents Risk Category: II PV System Type SolarCity SleekMountm Spanish Tile Roof Spanish Tile Roof Layers of Comp Roofing ' Roof Slope 23° Rafter:Spacing 24"O.C. PV System Module Orientation Landscape and Portrait PV Module Area 264 s€ w x; 4 u P R T I N PV Module Width " 39 ,,,i' x,F :uildin PV M,bdule Length 65" `,sv 9 Department Standoff(Attachment Hardware) Mighty Hook HOG ST EJ FEB 21 2014 Ground/Roof Live/Snout Loads: Ground Snow Load 0 0 psf ''P':',:,,,,'''''':: =';':::'1, 5ur:roundingRoof$00 . 0.0psOR CODE COMPL(�►NC Roof Snow Over PV Modules 0.0 psi 'ASCE Eq:7.4-1 . Review:d By: ,meq Wind;Design.Criteria Wind Design Code ASCE 7-10 Windl)esigri Method Parlially/FulIy,Enclosed Method Basic Wind Speed V 110 mph ' Fig 26.5-1A ure Ca1eggry C Sedion2267 Expos Roof Style Gable/Hip Roof Me,30 4 2WB/CSAIB Mean,Roof Heigbt 2 2 _ h it_ Section 6.2- Effective Wind Area(1 Module) A 17.6 sf IBC 1509.7.1 Wind-Pressure Calcu(at on,Coeffiotents, ..N ..., Wind Pressure Exposure It 0.95 Table 30 3-1 Tc)ptigraphfe Foot tfzt 100 Sect30n 2b_. Wind Diredlonality Factor Kd 1185 Section 26.6-1 Ik17Uor'#ance Fader r NA:; , . Velocity Pressure qh qh=O.OQ256 (Kzt)(Kd)(Y^2) Equation 30.3-1 24.9 psf Ext.Pressure Coeffident(UO GCp(Up) -0.88 ne 304-2A/13/C5A/8 ExtTf utke lfficlitf:(DOOWn).. GCRi'.ttIVI1); .. ._.,:;;ri- ' 0....45 <._. ..F .:gl=2A/al slll.- Design Wind Pressure p p=qh(GCp) Equation 30.4-1 .d gi . .._ _.PCW),L .. _ ._., _.__ Wind Pressure Down p(dowa) 16.0 psi mistabiewwdievorialikattat.,;(it-.7- e, i .�>a4x%'�§' ��s"S�iT),4r74':Ve4nY;, ,a�` �Ya- t o',F'^ .Mat'r^4 `,.f WOO Max Allowable Standoff Spacing Landsca e2" 72" 52" Standoff Configuration Landscape Not-WV PV Assembly Dead Load W-PV � 3 psf ttfet„iYiiSd,13pTift i- i ff 17.r.4-41 --, 911 Uplift Capacity of Standoff T-allow_ 350 lbs Standoff Demand/Capacity DCR: 84.810 Max Allowable Standoff Spacing Portrait 48" 52" Max.Allowable Cantilever Pati it 20" 24 Standoff Configuration Portrait Not-Staggered MaxStendoff.Tributaiy.Areaa Trib 17 sf: PV Assembly Dead Load W-PV 3 pst Net 1Nind Uplift atStandgff" T 6iial198:ibs Uplift Capacity of Standoff T-allow 350 lbs Standoff Oemand[Capadty Def 96.5% CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J B-9502675 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: ���_} ■ BENSHALL NOT BE USED FOR THE YOH, DAISY YOH RESIDENCE Armand DeBose /,�SofarCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: ;z NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 18630 RUNG CT 3.75 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES CUPERTINO, CA 95014 4 ORGANIZATION, EXCEPT IN CONNECTION WITH3055 Gearview Way THE SALE AND USE OF THE RESPECTIVE (15) Advantage Module SHEET: REV: DATE: San Mateo,CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PAGE NAME T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. INVERTER: SOLAREDGE # SE3800A—US—ZB—U (408) 828-7968 UPLIFT CALCULATIONS PV 4 2/20/2014 (888)—SOL—CITY(765-2489)www.solarcty.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) UFER AT PANEL Panel Number:CHALLENGER Inv 1: DC Ungrounded INV 1 —(1)SOLAREDGE ## SE3800A—US—ZB—U LABEL: A —(15)Advantage Module CA # 888104 WITH IRREVERSIBLE CRIMP Meter Number:1009674267 Inverter; 38u0W, 240V, 97.5%; w/Unifed Disco and ZB, AFC' PV Module; 250W, 227.9W PTC, Poly, 60cell, Blck Frame, White Bcksht, ZEP C-10 INV 2 Voc: 38.4 Vpmax: 30.1 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER nE 200A MAIN SERVICE PANEL E 200/2P MAIN CIRCUIT BREAKER Inverter 1 200A/2P 0SE38 0A SOLAREDGE �� (E) LOADS n L1 1240V I SolarCity • —• • L2 ----r GFP/GFCI A N 2 Q 20A/2P _ EGC/ _———-IDC- •� DODG C+ 1 Strings)Of 15 On MP 1 GEC th7I'l m m ��•��— r'—— I GND EGC EGC I J —• • • 1 '--- —�, I I r. " N I -- J o EGC/GEC 1v___0-—GEC —, • I I Z (E)20A/2P 1 1 R q' N(E) 10 PANEL PV k BuildingDepartment TO 120/240V —• - SYSTEM WITH 20A OF SINGLE PHASE p L— PV BACKFEED , UTILITY SERVICE I .,� �,; FEBI 21 2014 REVIEWED FOR CODE� C,O{MPLIANCE • Reviewed By: L- 9 Voc* = MAX VOC AT MIN TEMP y# POI-(1)CUTLER—HAMMER #BR220 PV BACKFEED BREAKER /fj C A —(1)So STRMGS,SUNIFUSED GROUNDED DC Breaker, 20A 2P, 2 Spaces —(1)ZEP/650-1196-002 Universal Box Bracket; [PKG B] PV 1-(15)SOLAREDGE 1'30Q-2NA4AZS PowerBox Optimizer, 300W, H4,DC to DC, ZEP (1)AWG#10, THWN-2, Black —(1)AWG #10, THWN-2, Black Voc* =500 VDC Isc =15 ADC (2)AWG AWG#10, PV WIRE, Black Voc* =500 VDC Isc =15 ADC O[3,1—(1)AWG #10, THWN-2, Red O 4—(1)AWG#10, THWN-2, Red Vmp =350 VDC Imp=10.58 ADC O —(1)AWG#10, Solid Bare Copper EGC Vmp =350 VDC Imp=10.58 ADC (1)AWG#10, THWN-2, White NEUTRAL Vmp =240 VAC Imp=15.83 AAC (1)AWG#10, THWN-2, Green EGC —(1)Conduit Kit; 3/4' EMT . . .-(1)AWG #8,.THWN-2,.Green . . EGC/GEC-(1)Conduit_Kit;.3/4'.EMT.. .. .. .. .. CONFIDENTIAL— THE INFORMATION HEREIN JOB NUMBER: J 3-9502675 00 PREMISE OWNER: DESCRIPTION: DESIGN: -"! CONTAINED SHALL NOT BE USED FOR THE YOH, DAISY YOH RESIDENCE Armand DeBose ;;So�arCity BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: P NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 18630 RUNO CT 3.75 KW PV Array �: PART TO OTHERS OUTSIDE THE RECIPIENTS MoODLEs CUPERTINO, CA 95014 ORGANIZATION,EXCEPT IN CONNECTION WITH 3055 Clearview Way THE SALE AND USE OF THE RESPECTIVE (15) Advantage Module PAGE NAME SHEET: REV: DATE San Mateo, CA 94402 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: T:(650)638-1028 F:(650)638-1029 PERMISSION OF SOLARCITY INC. SOLAREDGE # SE3800A—US—ZB—U (408) 828-7968 THREE LINE DIAGRAM PV 5 2/20/2014 (888)—SOL—CITY(765-2489)www.solarcity.com Hardware Qty Model Voltage Drop Calculations Module: 15 Advantage Module 250 Vdrop= (Imp) * (2*Length) * (Resistance) /(Vmp) DC Converter: 15 SolarEdge OP250-LV Inv Power DC W PTC DC W STC Inverter A Imp(A) Max. Length (ft) Wire Inverter A: 1 SolarEdge 3800 3800 3350.13 3750 Input: 8.31 40 AWG_10 Inverter B: Vdrop= (8.31 * 80 *0.00124 Ohms) 404.76975 0.26 3800 3350.13 3750 Inverter A Imp(A) Max. Length (ft) Wire Output: 10.58 50 AWG_10 Vdrop= ( 10.58 * 100 *0.00124 Ohms) 404.76975 0.32 Inverter A Stringing Inverter B Stringing Comb. Drop Imp(A) Max. Length(ft) Wire String 1: 15 Modules String 1: Modules 10.58 10 AWG_10 String 2: Modules String 2: Modules Vdrop= ( 10.58 * 20 *0.0012 Ohms) 0.1058 0 Photovoltaic Module Electrical Specifications: Photovoltaic Source Circuit(Modules to PowerBox) Voltage Drop Calculations °F °C Advantage Module 250 Voc at Min Temp= 42.71 V Record Low Temp: 17 -8 Power(STC)= 250 W Voc= 38.4 V Max Average High Temp: 87 31 Power(PTC)= 227.9 W Vmp= 38.4 V Voc= 38.4 V Vmp at Max Temp= 26.98 V Vmp=_ 30.1 V Isc= 8.87 A Isc= 8.87 A Imp= 8.31 A Imp= 8.31 A (cont= 11.09 A � CUPERTINO Tvoc= -0.13056 V/deg C 1 Building Department Tvmp= -0.13545 V/deg C AWG 12 Table 310.15(6)(16) ma;,, 4 Tisc= 5.7655 mA/deg C Ampacity= 30 > 13.86 A sE FEB 21 2014 Corrected Ampacity= 17.40 A > 11.09 A L, Temperature Derate= 0.58 Conduit Fill Derate= 1 REVIEWED FOR CODE COMPLIANCE Reviewed By: /4-Aikiprrriq DC Converter Electrical Specifications: Inverter A Input Circuit(PowerBox to Inverter) Unused SolarEdge OP250-LV String 1 Power= 250 W Vmax= 500 V Wire Length 40 Vmax= 500 V Wire Length 50 Efficiency Factor= 0.987 Vmp= 350 V Vmp= 350 V Vmin_input= 5 V !max= 15 A Imax= 15.00 A Vmax_input= 60 V Imp= 6.77 A Imp= 6.77 A Imax_input= 10 A Vmax_output= 500 V AWG 10 90°C:Table 310.15(6)(16) 90 C:Table 310.16 Imax_output= 15_ A Ampacity= 40 > 15 A Ampacity= > A Corrected Ampacity= 23.20 A > 15 A Corrected Ampacity= A > A Temperature Derate= 0.58 Temperature Derate= Conduit Fill Derate= 1 Conduit Fill Derate= OCP= 20 A OCP= A DC Converter Electrical Specifications: Inverter A Output Circuit Combined Inverter Output Circuit SolarEdge 3800 Service Voltage= 240 V Service Voltage= 240 V Power= 3800 W Icont= 15 A Wire Length 10 Icont= _ A Wire Leng:h Vmp_input= 350 V Vmax_input= 500 V AWG_10 90°C:Table 310.15(6)(16) 90 C:Table 310.16 Imax_input=_ 12.664 A Ampacity= 40 > 18.75 A Ampacity= > A Vmax_output= 240 V =Service Voltage Corrected Ampacity= 36.4_A > 15 A Corrected Ampacity= A > A Imax_output=1 15.83 A =lcont Temperature Derate= 0.91 Temperature Derate= Conduit Fill Derate= 1 Conduit Fill Derate= OCP= 20 A OCP= A CONFIDENTIAL- THE INFORMATION HEREIN JOB NUMBER: J 8-9502675 0 0 PREMISE OWNER: DESCRIPTION: DESIGN: \\�1NSHALL NOT BE USED FOR THE YOH, DAISY YOH RESIDENCE Armand DeBose .4,1 CONTAINEDD BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: '��SolarCity NOR SHALL IT BE DISCLOSED IN WHOLE OR IN ZEP Mighty Hook 18630 RUNO CT 3.75 KW PV Array PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES CUPERTINO CA 9501 4 3055 Clearview Way ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE (15) Advantage Module PAGE NAME SHEET: REV: DATE San Mateo,CA 94402 PERMISSION EOFIPSOLLAATRgn II C. THE WRITTEN INVERTER: (408) 828-7968 PV 6 2/20/2014 _(650)638-1028 F:(650)638-1029 SOLAREDGE # SE3800A-US-ZB-U ELECTRICAL CALCULATIONS (888)-SOL-CITY(765-2489)www.sdarcity.aom Label Location: Label Location: Label Location: WARNING:PHOTOVOLTAIC POWER SOURCE (C)(IC)(CB) (AC) WARNING (DC)(INV)(CB) Per Code: PV SYSTEM Per Code: DISCONNECT FOR ELECTRIC SHOCK HAZARD CRC R331.2 UTILITY OPERATION THE DC CONDUCTORS OF THIS CEC 690.35(F) Label Location: PHOTOVOLTAIC SYSTEM ARE TO BE USED WHEN PHOTOVOLTAIC DC (DC)(INV) UNGROUNDED AND INVERTER IS Per Code: MAY BEE ENERGIZERGIZED UNGROUNDED DISCONNECT CEC 690.14.C.2 Label Location: WARNING (DC) Label Location: ELECTRIC SHOCK HAZARD CEC 690.17 DO NOT TOUCH TERMINALS MAXIMUM POWER- (DC) (INV) TERMINALS ON BOTH LINE AND POINT CURRENT(Imp) Per Per Code: LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION MAXIMUM POWER- V CEC 690.53 POINT VOLTAGE(Vmp) MAXIMUM SYSTEM v VOLTAGE(Voc) SHORT-CIRCUIT CURRENT(Ise) A Label Location: WARNING (P0Pe1) Code: INVERTER OUTPUT CEC 705.12.D.7 CONNECTION _ Label Location: DO NOT RELOCATE ( :R ,��s CUPERTINO THIS OVERCURRENT t --.�Y� CUPERTINO WARNING (°C)(cg) DEVICE I / s Building Department Per Code: h:'-'7!"'''.'---• :'.',.1-- ELECTRICAL SHOCK HAZARD CEC 690.17 DO NOT TOUCH TERMINALS ,.-.> ' ;`-_' TERMINALS ON BOTH LINE AND FEB 21 2014 LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Label Location: REVIEWED FOR CODECOMPLIANCE DC VOLTAGE IS PHOTOVOLTAICN POCTIOT OF (P01) Reviewed By: ti—}1...\--,244r-01•9. ALWAYS PRESENT WHEN INTERCONNECTION Per Code: SOLAR MODULES ARE WARNING:ELECTRIC SHOCK EXPOSED TO SUNLIGHT HAZARD.DO NOT TOUCH CEC 690.54; CEC 690.17 TERMINALS.TERMINALS ON BOTH THE LINE AND LOAD SIDE MAY BE ENERGIZED IN THE OPEN POSITION. FOR SERVICE Label Location: DE-ENERGIZE BOTH SOURCE WARNING (NV) AND MAIN BREAKER. ( PV POWER SOURCE Per Code: MAXIMUM AC ELECTRIC SHOCK HAZARD CEC 690.5(C) OPERATING CURRENT _ A IF A GROUND FAULT IS INDICATED MAXIMUM AC NORMALLY GROUNDED OPERATING VOLTAGE _ V CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED Label Location: Label Location: (D) (P01) PHOTOVOLTAIC AC (AC) ( ) CAUTION (AC):AC Disconnect AC POI PHOTOVOLTAIC SYSTEM Per Code: (C): Conduit DISCONNECT Per Code: CIRCUIT IS BACKFED CEC 690.64.8.4 (CB): Combiner Box CEC 690.14.C.2 (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit Label Location: Label Location: (INV): Inverter With Integrated DC Disconnect MAXIMUM AC _ A (AC)(P01) CAUTION (P01) (LC): Load Center OPERATING CURRENT Per Code: DUAL POWER SOURCE Per Code: (M): Utility Meter MAXIMUM AC CEC 690.54 SECOND SOURCE IS CEC 705.12.D.7 (P01): Point of Interconnection OPERATING VOLTAGE _V PHOTOVOLTAIC SYSTEM CONFIDENTIAL- THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR `0114 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED i. • San Mateo,CA 94402 SC — CA Label SetT:(650)638-1028 F:(650)638-1029 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, ��� Siiiar( 1�� (888)-SOL-CITY(765-2489)www.solarcity.com EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. SolarCity SleekMountTM - Tile SolarCity SleekMountTM - Tile ' The SolarCity SleekMount hardware solution •Utilizes Zep Solar hardware and UL 1703 listed ,. Installation Instructions is optimized to achieve superior strength and Zep CompatibleTM modules aesthetics while minimizing roof disruption and Remove tile and locate rafter •Interlock and grounding devices in system UL \, \ labor.The elimination of visible rail ends and listed to UL 2703 Drill pilot holes of proper diameter for • mounting clamps, combined with the addition .,,` fastener size per NDS section 1.1.3.2 of array trim and a lower profile all contribute to •Interlock and Ground Zep ETL listed to UL 1703 Seal pilot holes with roofing sealant as"Grounding and Bonding System" a more visually appealing system. SleekMount ����� . Place tile hook rM •Ground Zep UL and ETL listed to UL 467 as 4 . utilizes Zep Compatible modules with �` � strengthened frames that attach directlyto Zepgrounding device .-F t-, Install lags pursuant to NDS section 11.1.3 g �,'" '�� � ,, with fender washer Solar standoffs,effectively reducing the number •Anodized components for corrosion resistance of standoffs required, when compared to Notch underside of tile and reinstall tile . conventional rail-based systems. •Applicable for vent spanning functions Attach Spanner Clamps and tighten firmly in place Insert Cam Foot into Spanner Bar and rotate Cam Nut 100 degrees Components lace modules • Cam Foot tic Spanner Bar 3/8"Machine Screw and Nut n :CadPUi ngDepartment Spanner Bar Clamp ,d ® Tile Hook . k' �� FEB 21 2014 Lag Screw(2) ' REVIEWED FOR CODE COMPLIANCE --.....,,, t 0 1 ® ip Reviewed B . iiir. .*ti4riii, • : .i,,„ "i)ire SolarCityo January 2013 SRA e 1 LISTED ��� SolarCitym January 2013 SolarCity Advantage Module Electrical Parameters at Standard Test Conditions(STC) The SolarCity Advantage module represents a 60 Cell,ZEP enabled Power Output Pmax W 245 250 module.The values shown are the most extreme potential values Power Output Tolerances APmax W -0/+5 -0/+5 _ from SolarCity's portfolio of CEC approved and UL or ETL listed Module Efficiency nm % 15.23 15.54 modules. Modules will have a minimum 10 year warranty.The Maximum Power Voltage Vmp V 30.2 30.1 module installed will be one of the following: Maximum Power Current Impp A 8.17 8.31 Open-circuit voltage Voc V 37.8 38.4 Yingli Solar:YL2XXP-29b Short-circuit current Isc A 8.63 8.87 Trina Solar: PA05.18 ReneSola:JC2XXM-24Bb Values at Standard Test Conditions STC(Air Mass AM1.5,Irradiance 1000W/m2,Cell Temperature 25°C). BenQ: PM245P01_2XXW Canadian Solar: CSPX-2XXPX Electrical Parameters at Nominal Operating Cell Temperature(NOCT) Power Output Pmax W 178 185 Voltage at Pmax Vmpp V 27.8 27 Current at Pmax Impp A 6.54 6.7 Open-circuit voltage Voc V 34.5 35.4 Short-circuit current Isc A 7.08 7.25 NOCT:Irradiance at 800W/m2,Ambient Temperature 20°C,Wind Speed 1M/s. Thermal Characteristics Nominal operating cell temperature NOCT °C 46+/-2 Temperature coefficient of Pmax y %/°C -0.45 Temperature coefficient of Voc Voc %/°C -0.34 Temperature coefficient of Isc alsc %/°C 0.065 General Characteristics Solar Cells Multicrystaline Frame Aluminum alloy/anodized black Weight 45.2 lbs(20.5 kg) M73-7, ' 1 Bu!iding Department j FEB 21 2014 REVIEWED FOR CODECOMPLIANCE Reviewed By: lErirrrrq _____ _ yG E z 6 0 YG E a YL245P-29b YGrZ 60 CELL SERIES Powered by YINGLI CELL SERIES YL240P-29b YIN LI -OLAR YL235P-29b •9/1 ELECTRICAL PERFORMANCE YL230 P-29 b U.S.Soccer Powered by Yingli Solar Electrical parameters at Standard Tex Conditions(STC) GENERAL CHARACTERISTICS Module type YL250P-29b YL245P-29b YL240P-29b YL235P-29b YL230P-29b Dimensions(LJW/H) 64.96 in(1650 mm)/38.98 in(990 mm)/ Power output Pr... W 250 245 240 235 230 1.81 in(46 mm) - Power output tolerances �APm<. W -0/+5 Weight 45.2 lbs(20.5 kg) YINGLI SOLAR Z SERIES Ideal for residential Modals efficiency O m 1 153 15.0 14_7 14.4 ] '14.1 and commercial applications where cost savings, Voltage at PIVma V 30.4 30.2 _ 29.5 29.5 29.5 Current at P.... Jima A 8.24 8.11 8.14 7.97 7.80 PACKAGING SPECIFICATIONS installation time, and aesthetics matter most. Open-circuit voltage jV°, I V 38.4 37.8 _ 37.5 -37.0 37.0 Number of modules per pallet 22 Short-circuit current IK A 8.79 8.63 8.65 6.54 8.40 Number of pallets per 53'container 36 iance,25°C ture,AM1.5g spectrum according to \ - - \ ° Average relative0 efficiency reduction Of 5.0%oat 200W/rn according to EN 60904-1 EN 60904-3 Packaging box dimensions(L/W/H) 67 in(1700 mm)/45 in(1150 mm)/ -- Electrical parameters at Nominal Operating Cell Tempeaature(NOCT) Box weight Best Choice for INSTALLERS 0 Lower balance-of-system costs with Ze 47 in(1190 mm) P 0761 kg) Compatible frame. ______ - lbs(488 -'�, Power output a P.,.. W 181 1 177.9 174.3 170.7 167.0 ►Reduce on-roof labor costs by more than 25%. - wimp. VmP•+ V 276 27.2 26.6 26.6 26.6 Units:inch(mm) _- _ %' Current at P.... ha• A 6.56 6.54 6.56 6.42 6.29 ►Leverage the built-in grounding system- j - 38.98(990/ / Open circuit voltage V. V 35.4 34.5 34.2 33.8 33.8 • if it's mounted,it's grounded. / - - - 36.85(936) 1.81(46) - / - � Short-circuit current I, I A 7.12 6.99 701 6.92 6.81 itg ►Lower your parts count-eliminate rails,screws, \,,,,% \ in:1- CL , mounting clips,and grounding hardware. / NOCT open-circuit module operation temperature at 800w/m'irradiance,20°C ambient temperature,1 m/s wind speed rt ►Design and permit projects easily with access - , - �•\.� THERMAL CHARACTERISTICS to layout calculator and stamped drawings. Nominaloperating cell temperature NOW r. °c a6+/-z 8 \\ , Temperature coefficient of Peei y %/°C -0.45 Best Choice for.HOMEOWNERS � Temperature coefficient of Ve, Pen %/°C -0.33 ►Lower installation costs with savings across Temperature coefficient of I. aa. %/°C 006 Grounding hoiese a Fo .6-x0.236(6) equipment and labor. i, GOMpq Tye Temperature coefficient of V wn Bwq. C 0.45 m $ ►Minimize roof penetrations while maintaining �8Q „, the system's structural integrity. j_ OPERATING CONDITIONS ►Invest in an attractive solar arraythat includes s Max.system voltage 605Voc Mounting holes �� `\ SFA v 4-0.256x0.315(6.5x8) a black frame,low mounting profile,and ,s, ! .� COMpP�\� Max.series fuse rating 15A 66- aesthetic array skirt. ��. ', Limitingreverse current 15A C'4 - Drainage holes ►Increase energy output with flexible module Operating p rangeI 00.1200.315(3x8) ,.fu O atin temperature -00to 194°F to 90°C) NI l' L� layouts(portrait or landscape). Z E P COMPATIBLE FRAME Max.static load,front(e.g.,snow and wind) 50 psf(2400 Pa) 1 3.94(100) WARRANTIES ______ ` ►Trust in the reliability and theft-resistance of ,, Max.static load,back(e.g.,wind) 50 (a the Ze Compatible-system. Leadinglimitedwarran ensures � RT!NO %047(I P P y power �a Hailstone impact ;' y 1, (25 m)4 5 Jnph(2 m/s) 91.2%of rated power for 10 years,and 80.7% r building Department , of rated power for 25 years. I' / 1 -',,'•..47X,--;,..-..,,-- t, ' CONSTRUCTION MATERIALS t AC SOLUTION OPTION �n("'t i SECTION Front cover(materiaVtype/thickness) I "i -ron glass d{J3 2 m viral. t I The YGE-Z Series is now available as 10-year limited product warranty. ° &_"",+ayhav gLL1I -- an Enphase Energized AC Solution cell( anti /material/ a/dimensions/ 60/ lion/must= Irne/ ` 1 '109u ty tY'P P Y 0 v` 7 r This solution delivers optimum \, area/8 of busbars) o l' C�V�V�Cm LyJs¢f ny��J r�Cg3. ENERGIZED *In compliance with our warranty terms and conditions „ : , + Enca s)ant materiae R F V I E Ethylene vin acetate(EVA) t _-O M P L IAN CE' 1 3 m performance and integrated intelligence. \ v P a ( Y Y a The Enphase M215-Z Zep Compatible Microinverter w Frame(material/color) 1�20nF P ins alloy/bl k .A,y', C/ `° '� -.R.bkn-i s 4' Y I Warning:Read the Installation and User Manual in its entirety is designed to connect directly into the Z Series module QUALIFICATIONS&CERTIFICATES Junction box(protection degree) oIP65 before handling,g,installing,and operating Yingli modules. groove,eliminating the need for tools or fasteners- Cable(type/length/gauge/outside diameter) PV Wire/43.31 in(1100 mm)/12 AWG/0.244 in(6.2 mm) all with one easy step. UL 1703 and ULC 1703,CEC,FSEC,ISO 9001:2008, Plug connector Amphenol/H4/IP68 Our Partners 1110111. 2111 ISO 14001:2004,BS OHSAS 18001:2007,SA8000 (manufacturer/type/protection degree) '" '"`"" ..�.._ O g The specifications in this datasheet are not guaranteed and are subject to change without prior notice. CO L US F^ti () je"b; ' CERT'. n; This datasheet complies with EN 50380:2003 requirements. - Intelligent real-time iaaoro,mLn,E�oouua o.r..e.., P ' MI a monitoring at the system 44DD ...,....a. and module level with Enlighten. Yingli Green Energy Americas, Inc. info©yingliamericas.com __I - �� Tel +1 (888)686-8820 YING I -ALAR !i �;j� YINGLISOLAR.COM/USI NYSE:YGE !® YINGLISOLAR.COM/US 1 Yingli Americas / ' 0Mngli Green Energy Holding Co.Ltd. I YGEZ60CellSenes2012_EN_201206_V01 U.S.Soccer Powered by Yingli Solar GreenTriplex PM245P0 I (245 - 260Wp) GreenTriplex Electrical Data Dimensions mm[inch] P M 24 5 PO I Typ. I I 40 Nominal Power PN 245 W 250 W 255W 260 W Fronto esu 983 -{ wgMvier, [38.70] I [1.57] Typ.Mominaliciency 15.2% 15.5% 15.8% 16.1% Typ.Nominal Voltage V,,,P(V) 30.3 30.6 30.8 31.2 IIIIIIIIIIIIIIIIIIIIII Typ.Nominal Current Imp(A) 8.09 8.17 8.28 8.34 IIIIIIIIIIIIIIIIIIIIII Multi-Crystalline Typ.Open CircuitVoltageVoc(V) 37.2 37.4 37.6 37.7 IIIIIIIIIIIIIIIIIIIIII Photovoltaic Module Typ.Short Circuit Current lsc(A) 8.64 8.69 8.76 8.83 IIIIIIIIIIIIIIIIIIIIII Maximum Tolerance of PM 0/+3% 1639 1111111111111111111111 -_ _ [6es2] IIIIIIIIIIIIIIIIIIIIII Abaedmareheefeoe etatsanmarenconadon:(area sem- - •STCimd'once 1000W/m..spectral distribution i5,tempenare25 t 2°C,in accordance with EN 60904-3 1111111111111111111111 'I • •,.-- - •Thefon&coiW dm are nominal values which account basic measurements and manufacturing tolerances of NM:NO the '0.0...-am ;,- v v Power Range l of classifications is performed accorsngus lV. V IIIIIIIIIIIIIIIIIIIIII •�••.•do - 2 245-260 Wp Temperature Coefficient ',, '•'® 260W 1111111111111111111111 ry�:` y.�..•:aa .~v NOCT 46±2°C 're.:�:-___."' Typ.Temperature Coefficient of PM -0.44%/K IIIIIIIIIIIIIIIIIIIIII + ' '' i Highly Strengthened Design Typ.Temperature Coefficient ofVoc -0.32%/K Bad Yew 928" 3654 ] Module complies with advanced loading tests to Temperature Coefficient of Isc 0,04%/K (o•htanre between two Mountlng Holes) meet 2400 Pa loading requirements } e°]unction Box' [045] . ' 1 1 1114 •NOCLNomd Operation CdlT pemture,measumgcondmothaimd'once BOOW/ms,AM 13,air temperature 20°C,Wind speedlmfs 31.8 i I� [1291] T Mechanical Characteristics [I'] ;1.S••;, ``� J" IP-67 Rated Junction Box Dimensions(L xW x H) 1639 x 983 x40 mm(64.53 x 38.70 x 1.57 in) fl\0 0 0 -, _- i `�," IP 6 j Advanced water and dust proof level 1000 3s +\`04i. , _ .�; 67 'g Weight 19.5kg(43 lbs) [3937] 4 -1 ��0�� i 1.'4' 4' Front Glass Hi,g,ah,transparent solar ass(tempered),3.2 mm(0.13 in 983* �4,046% �� I ♦ cap` 'I I 'S'° spare ( Pe'"'/• \ ) [3a70] ` E A-A Cross Section +' ,�����00 46 I Cell 60 muhicrysrelline solar cells 156 x 156 mm(6"x 6 0 q - • .,T - -, Integrated Racking Solution Ce®Encapsulation EVA MW e �� i tc 6_ I, ~ n Simplifies installation process and reduces labor Bade Sheet Composite film(White) bbin ®®`y21'14`® _ga 4, i '`!' costs ,,,,..%,...„....„,� I FAST frame Anodized aluminum frame(Black) •'441446414416 .'",,,,,, ♦r =011., ♦ t"- �, Junction Box IP-67 rated with 3 bypass diodes ,-: ''"4*�♦',4117♦�='44-41 Cables I x 4 mm�0.04 x 0.16 inch',len 1:each l.O m 39.37 in ,y u•sub,te y m : ( ) gth ( ) Grounding ��.`.'"-° ®;:,..'®.►� ,tttoMPATiee Connector Type Tyco PV4 HO.x4 N Cj ,`-,:+'� ; PV CYCLE ' ° IN Curve 14 curve vs diff.irradiance ys� w� rip g' Operating Conditions 9.0 �' cOMPP�e OperatingTemperature -40-+85°C a.° 1000 W/ 7.0 �,,�� • AmbientTemperatureRange -40-+45°C 60 803W/ma , Max System Voltage UL I000V40-500W fm - - ........ . Serial Fuse Rating ISA 2.0-400W , `. - - Maximum Surface Load Capacity Tested up to 2400 Pa according to ULI703 10 200W/m= � [}r 000 5 10 15 20 25 30 35 40 PO� Warranties and Certifications Voltage 3 _ 1ppr.. �w • a Produt'cWartanty Maximum 10 ,,,( i/x rad w r a P 1n. age characteristics with dependence on irradiance and module temperature. hdurzcten Performance Guarantee Guaranteed o . ��,1 I pr ears Certifications According to iii,,,, }y;t`, * IDflf ;. Sc) *Please confirm othercertifications with official dealers a f F 2 • Packing configuration 201 .. I - Container 20'GP 40'GP 40 HQ f,n 'x _,.� _r „r' Pieces per pallet 26 R E V i F V 26%---ljur J l a*•` (.' MPLlANC� .. $`, ", ./' t,,,-,,,,,v .:;----}- Pallets per container 6 14 28 e .,•,,• : Fit: r,. a d►- piecesper container 156 672: ❑ ❑ AU Optronics Corporation c ••1.-ii •a No.I,Li-Hain Rd.2,Hsinchu Science Park,Hsinchu 30078,Taiwan BenQ fQ BenQ .,,7_,. i. Tel:+886-3-500-8899 E-mail:BenQSolar@auo.com www.BenQSolar.com BenQ BenQ ;�F- L g Solar ❑ • j G • MO BenQ Solar is a division of AU Optronics ml:mita:heeti:printed ni milky Ink Solar 0 Copyright May2013 AU Optronics Corp.All rights reserved.Information nay change without notice. TSM-PA05.18 TRINAMOUNT II WITH THE UNIVERSAL MODULE Mono Multi Solutions DIMENSIONS OF PV MODULE TSM-PA05.18 ELECTRICAL DATA @ STC TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 PA05.18 PA05.18 1 PA05.18 PA05.18 PA05.18 941 mm Peak Power Watts-PMAx(Wp) 240 245 250 255 260 Power Output Tolerance-PMA.(%) 0/+3 0/+3 0/+3 0/+3 0/+3 _ ,uHcnoH o Maximum Power Voltage-VMr(V) 29.7 30.2 30.3 30.5 30.7 IMaximum Power Current-lee(A) 8.10 8.13 8.27 8.36 8.47 is M - PA05.18 NAMEPLATE 0o Open Circuit Voltage-Voc(V) 37.3 37.5 37.6 37.7 37.9 09x1] INSTALLING Short Circuit Current-Ise(A) 8.62 8.68 8.85 8.92 9.00 1 Module Efficiency Wn(%) 14.7 15.0 15.3 15.6 15.9 THE TRINAMOUNT MODULE 3 3 E STC:Irradiance 1000 Wim',Cell Temperature 25°C,Air Mass AMIs according to EN 60904-3. Average efficiency reduction of 4.5%at 200 W/m%according to EN 60904-1. E o in 3 0 3 ELECTRICAL DATA @ NOCT I TSM-240 TSM-245 TSM-250 TSM-255 TSM-260 CELL PA05.18 PA05.18 1 PA05.18 PA05.18 PA05.18 60 Maximum Power-PMA.(Wp) 174 178 181 184 188 Maximum Power Voltage-VMr(V) 26.6 26.8 27.0 27.2 27.4 MULTICRYSTALLINE MODULE ; `•4""°°"°'"G"°" A A Maximum PowerCurrent-IMrr(A) 6.55 6.64 6.70 6.77 6.86 WITH TRINAMOUNT FRAME l,.sSvsHOLE - Open Circuit Voltage(V)-Voc(V) 34.1 34.2 34.3 34.4 34.6 if Short Circuit Current(A)-Isc(A) 7.04 7.10 7.25 7.31 7.37 - 812mm 180 NOCT:Irradiance at 800 W/m',Ambient Temperature 20°C,Wind Speed 1 m/s. 240 260W Back View POWER OUTPUT RANGEOur most versitile product al MECHANICAL DATA ,1 • Compatible with all major BOS components and system Solar cells Multicrystalline 156 e 156 mm(6 inches) designs Cell orientation 60 cells(6.10) 15.9% Module dimensions 1650 x 992 x 40 mm(64.95 x 39.05.1.57 inches) Weight 18.6 kg(41.0 lbs) MAXIMUM EFFICIENCY fa Glass High transparency solar glass 3.2 mm(0.13 inches) Backsheet White One of the industry's most trusted modules r.,�%% • Over 2 GW sold across all major global markets Frame Black Anodized Aluminium Alloy with Trinamount Groove O el 3 • Field proven performance I-V CURVES OF PV MODULE TSM-245 PA05.18 J-Box IP 65 or IP 67 rated Cables Photovoltaic Technology cable 4.0 mm'(0.006 inches'), t0.. -- 1100 mm(43.3 inches) POWER OUTPUT GUARANTEE 9..-1000W/mom B' Connector Original MC4 Highly reliable due to stringent quality control -6P 61.10W/m4 _ 7 As a leading global manufacturer • Over 30 in-house tests(UV,TC,HF,and many more) 4.m-4opwtm' TEMPERATURE RATINGS MAXIMUM RATINGS of next generation photovoltaic • In-house testing goes well beyong certification requirements �5A3.W 200W/m' Nominal Operating Cell 45°C(±2°C) Operational Temperature -40-+85°C products,we believe close z° Temperature(NOCTJ cooperation with our partners 4° Maximum System 1000V DC(IEC)/ is critical to success. With local OP Temperature Coefficient of Fees -0.43%/°C Voltage 600V DC(UL) 0.00 10.°' 20.4° 3a. 40.40 presence around the globe,Trina is Voltage(V) Temperature Coefficient of Vac -0.32%/°C Max series Fuse Rating 15A able to provide exceptional service Temperature Coefficient of Ise 0.047%/°C to each customer in each market Certified to withstand challenging environmental and supplement our innovative, ,.v _7 C P^3 ,.Tf NO reliable products with the backing conditions t.,, 3- of Trina as a strong,bankable 130 km/hr wind load (2400 Pa) WARRANTY�c Building Department partner. We are committed • 900 kg snow load per module (5400 Pa) 10 year Pro ¢�d.lnitclikn'ar;v,ip Warranty to building strategic,mutually • --,r beneficial collaboration with 25 year Lin f f / r Worr,�nty rr. 1 installers,developers,distributors (Pleoserefer .t7ifyfor de u 2 2014 and other partners as the backbone of our shared success in CERTIFICATION REVIEWED FOR CODE COMPLIANCE o driving Smart Energy Together. LINEAR PERFORMANCE WARRANTY (� PACKAGING CONFIGURATION ��/�� 10 Year Product Warranty•25 Year Linear Power Warranty A. \ ® c G. Modules per box:2 PeWjwed By; �a "1 " Trina Solar Limited f www.trinasolar.com 5100% A� c L us Modules per 40'container:672 pieces ISO %� E ® Intel= ff 3 Adtlitio (j hal salve from w° U om Tri • 0 90% ha$OIar 511nCar warrant CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. GpMP4Tj Virtus®l� Module en a vIrtugIT RefleStIa 245W, 250W, 255W, 260W Dimensions 39.1 inches 1.6inches 39.1 Inches Virtus®�� Module ,° t000W/m 245W, 250W, 255W, 260W °���x1 73=01/.=� e , 1 a e n ���.r P V 4 1.1111111111 Efficiency High Module Conversion Efficiencies a e! ZEP - • o s ,o ,s zo zs ao ss °o CP 0 1 GROOVE Voltage- M Zep Compatible Varied Irradiation Efficiencies 1 •' _-___ /00.40411011 "c Irradiance 200W/mt 400W/m' 600W/m° 800W/m' 1000W/m: 0.". _ ----- --- • Drawing Only for Reference Efficiency 15.8% 16.2% 16.2% 16.1% 16.0% -2'°4 a:Mechanical Load Capability of up to 5400 Pa i . Electrical Characteristics STC JC245M-24/Bb JC250M-24/Bb JC255M-24/Bb JC260M-24/Bb / \ '--- Maximum Power(Pmax) 245 W 250 W 255 W 260 W I] Conforms with IEC 61215:2005, Power Tolerance 0-05W 0..+5W 0-KW 0-e5W Module Efficiency 15.1% 15.4% 15.7% 16.0% (LC 6® IEC 61730:2004,UL 1703 PV Standards � Maximum Power Current(Imp) 8.19 A 8.31A 8.39A 8.53 A Maximum Power Voltage(Vmp) 29.9V 30.1V 30.4V 305V Short Omit Curretrt(Isc) 8.73A 8.83A 8.86A 8.95A Open Grab Voltage(Voc) 37.3 V 37A V 375 V 37.6 V IC& ' Values at Standard Test Conditions STC(Air Mass AM1.5,Irradiance 1000W/mr,Cell Temperature 25°C) C.rfndonJ 1509001,OHSAS18001,1S014001 Certified � - - -- - - Electrical Characteristics NOCT JC245M-24/Bb JC250M-24/Bb JC255M-24/Bb JC260M-24/Bb . - Maximum Power(Pmax) 182 W 185 W 189 W 193 W Ai,` i Maximum Power Curtem(Imp) 6.53A 6.57A 6.63A 6.74A Maximum Power Voltage(Vmp) 27.9V 28.2V 28.5V 28.6V `f" O Application Class A,Safety Class II,Fire Rating C Short Circuit Current 7.04A 7.12A 7.20A 7.27A - Black also available Open amok Voltage(Voc) 35.0V 35.0V 35.1V 352V Values at Normal Operating Cell Temperature,Irradiance of 800 W/mr,spectrum AM 1.5,ambient temperature 20°C,wind speed 1 m/s =IIIIIIIIPPPPIIIIIIIIIIIIIMI 11112=11111111111111111111111111M1 Gine8 Cell Type 156 x156 mm Polycrystalline,60(6x10)pcs In series Temperature Coefficient of Voc -0.30%/°C Glass High Transmission,Low Iron,Tempered Glass Temperature Coefficient of 1st 0.04%/°C ���eg 10096- V e, 10096- Anodised Aluminum Alloy Temperature Coefficient of Pmax -0.40%/°C ,p9+ -year Junction Box IP65/IP67 rated,with bypass diodes Nominal Operating Cell Temperature(NOCT) 45°e22°C ur 95% Dimension •64.6x39.Iz1.6inches Add '�� material& �/' Oatput Cabk 12 AWG,39.4/47.2 inches 90% t tltletl Val workmanship \ li + Ue Weight 44.1 lbs C 85% '°:7.0Ve-'' y . Installation Hole Location See Drawing Above on v '` ." s''� 1 • € 80% k x o'h 0-year C l A;,'"4":,., yr 3 = ' F: � 0% T xF , , linear power output AContainer 20'GP 40'GP 40'HQ Operating Temperature -00°F-+385°F 0 1 5 10 15 20 25 Pallets per Container 12 28 28 Maximum System Voltage 1000VDC(EU)/600VDC(US) YEAR ----",, Pieces per Container 300 700 770 Maximum Series Fuse Rating ZOA(EU)/20A(US) x«x/lovmhars0ae'Cama km.Intolerance spa*. APPROVED PRODUCT uno:N riots,ese ed.oaPand5aunm,ubxa,°change...oder* Meq ` XN Ceus ( ( ID ( ) / ` EY ✓ uPV CYCLE • . r CUPERTINO U� '.x� W k4::::; vti MPp�a t T;'•4 Building Department FEB 21 2014 REVIEWED FOR CODE COMPLIANCE ReneSola.com ReneSola.com ',� Reviewed By: 1.+4 ' °q 9,,e CS6P-235/240/245/250/255PX Ne „gym �e CanadianSolar Black-framed Bteak0,0 Electrical Data STC CS6P-235PXCS6P-240PXCS6P-245PXCS6P-250PXCS6P-255PX Temperature Characteristics � Nominal Maximum Power(Pmax) 235W 240W 245W 250W 255W • �I Q Optimum Operating Voltage(Vmp) 29.8V 29.9V 30.OV 30.1V 30.2V Pmax -0.43%/°C N e W E d g G Tem erature Coefficient Voc -0.34%/°C III �1' 1. III "- Optimum Operating Current(Imp) 7.90A 29.9V 30.0V 30.1V 30.2V P Open Circuit Voltage(Voc) 36.9V 37.0V 37.1V 37.2V 37.4V lsc 0.065%/°C 1 II Short Circuit Current(Ise) 8.46A 8.59A 8.74A 8.87A 9.00A Normal Operating Cell Temperature 45±2°C Black-framed C S' 1 Module Efficiency 14.61% 14.92% 15.23% 15.54% 15.85% ''.. I!, Operating Temperature -40°C-+85'C Performance at Low Irradiance I 235/2401245/250/255PX Maximum System Voltage 1000V(IEC)/600V(UL) Industry leading performance at low irradiation - - _.P_ Maximum Series Fuse Rating 15A environment,+95.5%module efficiency from an 1 Application Classification ClassA irradiance of 1000w/m'to 200w/m' '' (AM 1.5,25'C I �+ �+ .,1 Power Tolerance 0-+5W ) Next Generation Solar Module Under Standard Test Conditions(STC)of irradiance of 1000W/m',spectrumAM 1.5 and cell temperature of 25'C NewEdge,the next generation module designed for multiple Engineering Drawings NOCT C86P-235PX CS6P-240PX CS6P-245PX CS6P-250PX CS6P-255PX types of mounting systems,offers customers the added Nominal Maximum Power(Pmax) 170W 174W 178W 181W 185W value of minimal system costs,aesthetic seamless Optimum Operating Voltage(Vmp) 27.2V 27.3V 27.4V 27.5V 27.5V I appearance,auto groundingand theft resistance. Optimum Operating Current(Imp) 6.27A 6.38A 6.49A 6.60A 6.71A I Open Circuit Voltage(Voc) 33.9V 34.OV 34.1V 34.2V 34.4V The black-framed CS6P-PX is a robust 60 cell solar module Short Circuit Current(Isc) 6.86A 6.96A 7.08A 7.19A 7.29A incorporating the groundbreaking Zep compatible frame. Under Normal operating Cell Temperature,Irradiance of 800 W/m',spectrum AM 1.5,ambient temperature 20V, The specially designed frame allows for rail-free fast wind speed 1 m/s installation with the industry's most reliable grounding Mechanical Data 1I system.The module uses high efficiency poly-crystalline Cell Type Poly-crystalline 156 x 156mm,2 or 3 Busbars ,.^- 1111 III Ill I Key Features silicon cells laminated with a white back sheet and framed Cell Arrangement 60(6x 10) I I I with black anodized aluminum.The black-framed CS6P-PX Dimensions 1638 x 982 x 40mm(64.5 x 38.7 x 1.57in) • Quick and easy to install - dramatically is the perfect choice for customers who are looking for a high Weight 20.5kg(45.2 lbs) I I I I I II I I I I reduces installation time quality aesthetic module with lowest system cost. Front Cover 3.2mm Tempered glass 1 11 Frame Material Anodized aluminium alloy • Lower system costs - can cut rooftop Best Quality J-BOX IP65,3diodes J 9) installation costs in half Cable 4mm'(IEC)/12AWG(UL),1000mm • 235 quality control points in module production connectors MC4orMC4 Comparable • Aesthetic seamless appearance - low profile • EL screening to eliminate product defects I Standard Packaging(Modules per Pallet) 24p a o with auto leveling and alignment • Current binning to improve system performance OA Module Pieces per container(40 ft.Container) 672pcs(40'HQ) • Accredited Salt mist resistant Mll • Built-in hyper-bonded grounding system - if it's IN Curves(CS6P-255PX) mounted,it's grounded Best Warranty Insurance �.__..._.. I ,1 • Theft resistant hardware • 25 years worldwide coverage I n _- - -..-- Section A-A • 100%warranty term coverage 9 1.______ 1• Ultra-lowpartscount - 3partsforthemounting • Providingthirdpartybankruptcyrights , 35.0II grounding system • Non-cancellable 5 A <0• Immediate coverage 5IIS ------- and • Industry first comprehensive warranty insurance by , AM Best rated leading insurance companies in the • Insured by 3 world top insurance companies a �� 9'�RT� worldCom rehensive Certificates 22 -�= I , ® r, ,• Industry teadingpius only power tolerance:0-+5W6 _°5 1 ;:.:::::)11:: : -�cGa eaa• IEC 61215,IEC 61730, IEC61701 ED2,UL1703, _ I ! ��}'�• Backward compatibility with all standard rooftop and CEC Listed,CE and MCS i n "'round mountin s stems yQ9 9 Y 1509001:2008:Quality Management System ---= � � § ��1• • ISO/TS16949:2009:The automotive quality 'Specifications included in this datasheet are subject to change without prior notice. • management system Rtw'i t= li i. _ • Backed By Our New 10/25 Linear Power Warranty About Canadian Solar OOMPL1�1NClo Plus our added 25 year insurance coverage • 15014001:2004:Standards for Environmental ( management system Canadian Solar Inc.Is one of the world's largest solar'<FCidlttedYaAUSeyli;ir wL -N D J{IYitihf ada in 2001 and was t97 - • QC080000HSPM:TheCertificationfor companies. As a leading vertically-integrated successfully listed on AS AQ Exchange (symbol: CSIQ) in aT Added Value manufacturer of ingots,wafers,cells,solar modules and November 2006. Canadian Solar has module manufacturing 90% From Warranty Hazardous Substances Regulations solar systems, Canadian Solar delivers solar power capacity of 2.05GW and cell manufacturing capacity of 1.3GW. • OHSAS 18001:2007 International standards for products of uncompromising quality to worldwide sax- occupational health and safety customers. Canadian Solar's world class team of 0% ' • • REACH Compliance professionals works closely with our customers to 5 10 15 20 25 P provide them with solutions for all their solar needs. Headquarters I 545 Speedvale Avenue West _ Guelph I Ontario N1K 1E61Canada d's t g •10 year product warranty on materials and workmanship 0 ' $p aC E -0- SGs1. l gr p Tel:+1 519 837 1881 •25 year linear power output warranty Fax:+1 519 837 2550 inquire.ca@canadIansolar-corn www.canadiansolar.com www.canadiansolar.com EN-Rev 10.17 Copyright 0 2012 Canadian Solar Inc. cc solar - • • = w solar " • • SolarEdge Power Optimizer N Module Add-On for North America — P300 / P350 / P400 SolarEdge Power Optimizer 2 P300 P350 P400 Module Add-On For North America ` (for60-cellPV (for 72-ceIIPV (for 96-ceIIPV 1/� modules) modules) modules) P300 / P350 / P400 1Z INPUT Rated Input DC Power�'� 300 350 400 O I W Y ¢ 4 ,# Absolute Maximum Input Voltage(Voc at lowest temperature) 48 60 80 I Vdc 2 i4 `q{ .. MPPT Operating Range 8-48 8-60 8-80 Vdc ; INA,,,,..- 40)...4.V14�. 02 CC Maximum Short circuit Current(Isc) 10 Adc ' c } {� Maximum DC Input Current 12.5 Adc b !r Maximum Efficiency 99.5 % "z, ,� ' , - Weighted Efficiency 98.8 % f �i'vr+p FI 'z"i,' ',.,::'5:,,, ,' M -'�Y �r,a' NI: x 5: ,,, 'te z 4' Overvokage Category II . " OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) d O Maximum Output Current 15 Adc Maximum Output Voltage 60 Vdc 7/. /1 OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) L� Safety Output Voltage per Power Optimizer 3 I Vdc STANDARD COMPLIANCE .r" a - EMC I FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 ,' r v $ O Sa IEC62109-1(class II safety),UL1741 I Yes ROHS „t '"�'^"'r"C ,?�. r''y > y - INSTALLATION SPECIFICATIONS 1es Vdc Maximum Allowed System Voltage i ;„` •lk5 � I Dimensions(WxLx H) 141x 212 x40.5/5.55 x 8.34x 1.59 mm/in y 950/2.1 gr/lb `�� 4 e w --..� � Weight(indudingcables) MC4/Am henol/Tyco ;/y ;.�J'' Input Connector p Output Wire Type/Connector Double Insulated;Amphenol ',IIi"/, ,s •,„ .I' I Output Wire Length 0.95/3.0 1 1.2/3.9 m/R -� F i�t^" Operating Temperature Range 40-+85/-40-.f185 'C/'F . ‘ �Y IP65 NEMA4 �. fkv �. Protection Rating / �y s 9 y+'*s ' Relative Humidity 0-100 % `� . M1 � u1Whd5T[0in>ottlemotlVe.MOEuleofuVW K%Wr'H[olenMltlbwed. } X. S sr ua .,. ; {S d-b'no n_ ss t s sz-0`"yr y , PV SYSTEM DESIGN USING A SOLAREDGE . THREEPHASE HASE THREE PHASE "4.-. , B4,:,/,*G a+ " ,1 ' * ''.•;,";,,,,,„,..„!7; z • " v"1?-c � , ' , SINGLE PHASE �„.,.,.,„,„"4..,.;,,,=',,,,, �+ ,PZ-,,,,a*� ^• a : r • L.:e ' 7 $- •" i ,. " ^ v ., ' ,t INVERTER 208V 480V ` vaS . ,`,.V -)& ,, v"� t y" „4�,1.' ., t t i ' '{ spsy4,, *3.4 .1 Z . y." Minimum String Length(Power Optimizers) 8 10 18 p gtt ' g ' ^ � 4 Maximum String Length(Power Optimizers) 25 25 50 ,C ,# te, . ds' rY, x ty,.; l ' ' eu5r %giffY , Maximum Power per String 5250 6000 12750 W Jss ,Ht Parallel Strings of Different Lengths or Orientations Yes - ,k ,, om ,u,, mmatc oses ommaRu ctrin a ce parhals;a (ng " F — Flexible system design for maximum space utilization • — Fast installation with a single bolt — Next generation maintenance with module-level monitoring — Module-level voltage shutdown for installer and firefighter safety CE 0 USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us osoia rarclmiooiogios.mc.nn ecros oyc,ro.so.�weoce.m�so,aees�'oso.oannu�eo av so.naroae mdsmwu vno� ,esus msoieraso mcnnoiogics.ioc.nu o:non,a�o,�ks, mo�m icma,o ��aa�ra�i�oiun,o�m�,ocu�o o,,00rs.o-am:xoi?ms.v.o�.s�¢oa�o rnooe�,wno�lnon�. -4-,---4---:, CUPERTIIVO B • uilding Department w' FEB 21 2014 REVIEWED FOR CODE COMPLIANCE / Reviewed By: C-A1 .111(cciy C so I a r SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ • • - Single Phase Inverters for North America solar - • • � � SE7600A-US/SE10000A-US/SE11400A-US IW I SE3000A-USISE3800A-USI 5200 SES000@A-US208V IsE6000A-USISE76o0A-US7680 SE9980 10000A-@US208V I SE11400A-US 11520 - SolarEdge Single Phase Inverters OUTPUT Nominal AC Power Output -. 3300 3840 6000 VA 5520 @240V 10080 @240V Max.AC Power Output 3650 4150 5600 @ 208V 6000 8350 10800 @ 208V 12000 VA For North America 6000 @240V 10950 @240V SE3000A US/SE3800A-US/SE5000A-US/SE6000A-US/ 183 AC o208t229VacVoltage Min.-Nom.-Max.* / - - / - SE7600A US/SE10000A US/SE11400A US 211 AC -264ageMin:Nom:Max.' / / / / / 211-240-264 Vac AC Frequency Min.-Nom.-Max.* 59.3-60-60.5(with HI country setting 57-60-60.5) Hz I 25 @ 208V I 48 @ 208V `w -.y a C Max.Continuous Output Current 14 16 23 @ 240v 25J 32 42 @ 240V 48 A C,� r j ay s )z t �s t �ys�' GFDI 1 A �.-44-q r''v "r, s*^'i t C'4" xa ,-;, l k w t T kr f"^A f .,,,� r p, y ,� ,fir Utility Monitoring,Islanding '`r,';�•�`;/+.g "itis � 1 Brte; k & *Aft CountryConfigurable Yes ,,, Protection,C t Li..," x",1 + dr ys s , 5` t,', l ` ;(�� Thresholds r"" :. ' �z 2 Z ° INPUT v ' rleafs k a n `�'�,), x d&y ,y„ ,�, .Wa t� r � fsl "vA �` Recommended Max.DC Power** l c @J8 '{r.. �� . 4100 4800 6500 I 7500 9600 I 12400 14400 W „, 5 �y +�' a ,z%i 1 'W*' (STC) 'Bran° z Transformer-less,Ungrounded Yes 1 t TI rR �F `g' ° ar~�w' -, g, y r„ .m d = Max.Input Voltage 500 Vdc "='''Mw.:-.,,,,g,...14---4,,,,,r,„;,,,,. , d �`s„ T y;7"s c "' Nom.DC Input Voltage 325 @ 208V/350 @ 240V Vdc '" ��' a -s,°A' ": "s " 1 17 @ 208V 1 33 @ 208V a >^+` r '. r �`'' Max.Input Current"' 11 13 17 @ 240V 18 23.5 30.5 @ 240V 35 Adcr T, x -:`^ � z ,;-,;-.4.1..-,;.,,,::?..: Max.Input Short Circuit Current 30 45 Adc r `2Ly - s s Reverse-Polarity Protect on Yes � � fe�`�,^ ! '' � ` Ground-Fault Isolation Detection 6001 Sensitivity " `r, �.___� �. :r/,�. Maximum Inverter Efficiency 97.7 98.2 98.3 98.3 98 98 98 '+ CEC Weighted Efficiency 97.5 98 97.5 @ 208V 97.5 97.5 97 @ 208V 97.5 % 98 @ 240V 97.5 @ 240V I Nighttime Power Consumption <2.5 e 4 W � } l�z i ADDITIONAL FEATURES $ Supported Communication Interfaces I R5485,RS232,Ethernet,ZgBee(optional) i '' ��`4 f ,, ,, s� �� . `/f STANDARD COMPLIANCE �t # tx ' =f Safety UL1741,UL36998(Part numbers ending in"-U"),U11998,CSA 22.2 TZn „;; f r• ^', ,r"F'•x Grid Connection Standards IEEE1547 ;g r to Emissions FCC part15 class B c aI 7 INSTALLATION SPECIFICATIONS k AC output conduit size/AWG range 3/4"minimum/24-6 AWG 3/4"minimum/8-3 AWG DC input conduit size/#of strings/ x; a 1 z .i 3/4"minimum/1-2 strings/24 6 AWG 3/4"minimum/101.-52 strings/14 6 AWG I AWG ranoe -�'. r "I. ,,,,�- Dimensions with AC/DC Safety 30.53x/41'2' 0.5 x 12.5 x 7/ 30.5 x 12 5 a 7.5/ 30.5 xi 12.5 x /775x315 x 260 in/ �� � Switch(HxWxD) 775 x 315 x 172 7- MITI Weight with AC/DC Safety Switch 51.2/23.2 +t l • CU P1 lb/kg Q y t .. Akc „ •q r >: `'s Cooling Natural Convectio n: U FlUIS user eplacea le) „{ 7 ,,; «` rtti w � AP,, cy Nwt, k .., t F tY u. 5 d.F i~ �;, ti.r x „�;'u � fi l- c+,' r x .x "a'•xtryv t" ° Noise <25 .A.�.•.. 9 F� �h dBA .� h. ,v `"r:14', i '4441,1.1'd,4' s 1'4; ,, ,'' ,'1 .V:',,,, 4`'11' '�? '�+ " s #,''u'`;� waa Y s`, "yqr• I� ,. pi r C„- x i 4F , ;� ' atr r S ..„�� , ', Awa '�,_ Min:Max.Operating Temperature w?-, ssss • The:best choice or'�SolarEdge enabled"system$ Range 13 to+14( Nversion 40 to+60) F/'C Protection Rating �M I3R Ftp. �a}} �. .a� Integrated arc fault protection(Type 1)for NEC 2011 690.11 compliance(part numbers ending in "-U') L.. G�a•� •For other regional settings please contact solarEdge support Superior efficiency(98%) "Limnedta125%forlocaeonswheretheyeartyaveregehightempeatureinabove77eF/25.Candto1319 Erledz'whenrittspebw.77s€/?SeC, For detailed intormahon,referto httn://www.solaredee.uslhles/odfs/inverter do oversking auide.odf /!r. t% : '.JI, L.i j -.....IP yIAN CE Small,lightweight and easy to install on provided bracket •."Ahigherturrent source may be sited;the nserterw 11 lim't'sinput current to the values stated. L Al • • •'CAN P/Ns are eligible for the Ontario FIT and mi<roF17(microFlrext.SE11400A-USAN) _ �/ w Built-in module-level monitoring ��v'� �� ' - Internet connection through Ethernet or Wireless - Outdoor and indoor installation - Fixed voltage inverter,DC/AC conversion only - Pre-assembled AC/DC Safety Switch for faster installation CO C� suns?Ec• Ro H S USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.US U Sclai l-.dl;o lu:hnulot;�es,In,:.All wilts iestivod.SUTARI-.1.0;1 the Solar.,Ig,••logo.OP11%1I/I:I4 B SULAPLINA ore trademarks or ' trademarks or Solorfdgc 14.0.fogies.Inc.All other trademarks mm�tioned herein are trademarks of 111 Ir rncnar;LV"owners.Dahl 82/201 A.0.111.S11411,1 In change wrlhnut nellie,