14040065 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 20663 CHERYL DR CONTRACTOR:JOSEPH AND DONNA PERMIT NO: 14040065 DIONNE OWNER'S NAME: JOSEPH AND DONNA DIONNE 20663 CHERYL DATE ISSUED:04/11/2014 OWNER'S PHONE: 4082506226 CUPERTINO CA,CA 95014-2909 PHONE NO: ❑ LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL COMMERCIAL E] REMODEL KITCHEN(132 S.F.)&FAMILY ROOM AREA License Class Lic.# S192 .F.).UPGRADE 100AMP PANEL TO 200AMP PANEL,SAME Contractor Date LOCATION I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$20000 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:35915039 00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city and county ordinances and state laws relating WITHIN 180 DAYS OF PERMIT ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We)agree to save 180 DAYS FROM LAST ED INSPECT ON. indemnify and keep harmless the City of Cupertino against liabilities,judgm costs,and expenses which may accrue against said City in consequence o Issued by: Date: granting of this permit. Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section 9 18. RE-ROOFS: Signature Date All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. OWNER-BUILDER DECLARATION Date: I hereby affirm that I am exempt from the Contractor's License Law for one of Signature of Applicant: the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, ch usiness&Professions Code) HAZARDOUS MATERIALS DISCLOSURE I,as owner of the property,am exclusively contracting with licensed contractors to construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay ea Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance wi he Cup ino Municipal Code,Chapter 9.12 and I have and will maintain Worker's Compensation Insurance,as provided for by the Health&Safety Code,Stetions 25 05,2553 ,an Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized agent: Date: permit is issued. I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If,after making this certificate of exemption,I become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C.)Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and e ses which ay accrue against said City in consequence of the I understand my plans shall be used as public records. granting olmr!ML plicant understands and will complywith all nCupertino Municipal Code,Section Licensed Professional 9 18. J Signature Date �, CONSTRUCTION PERMIT APPLICATION COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION O 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 CUPERTINO (408)777-3228• FAX(408)777-3333•building(1cupertino.org \ ❑NEW CONSTRUCTION ❑ ADDITION ❑ ALTERATION/Ti ❑ REVISION/DEFERRED ORIGINAL PERMIT# PROJECT ADDRESSZo3 CHERYL- DRLvE APNa O3 OWNER NAME y� — PHONE( ) 21'50- ZZ E-MAIL VOtJl�li� yOSS'P14 T)iovjoc �Ogl �oelYlRdion 1-2.A03C�b1nap• STREET ADDRESS 12-66V6 I t i Zt'L -Q=v E CITY, STATE,ZIPr-Ho o CA O15 O 14 FAX CONTACT NAME "� ` //��Op�631� ,Z HO�`NE�j�pg� Z50 E,-�IAIL OSt h 10�1N6 V O O 1 gi 0- (oZZ(v i�6kvna 'otn Zoo ei �ahoc c��v. STREET ADDRESS I / �!i(�, f CITY,STCE, ZIP FAX U �r� no C,a ❑OWNER GrOWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR ❑CONTRACTORAGENT ❑ ARCHITECT ❑ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR NAME LICENSE NUMBER LICENSE TYPE BUS.LIC# I b $E,�ETE2Mit�1C� COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE ARCHITECT/ENGINEER NAME LICENSE NUMBER BUS.LIC k COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE DESCRIPTION OF WORK U Ga-Aok-: FGtn�A (10644 EXISTING USE PROPOSED USE CONSTR TYPE I 4 STORIES USE TYPE OCC. SQ.FT. VALUATION($) EXISTG NEW FLOOR DEMO TOTAL AREA AREA AREA NET AREA BATHROOM KITCHEN OTHER REMODEL AREA REMODEL AREA /j REMODEL AREA PORCH AREA DECK AREA TOTAL DECK/PORCH AREA GARAGE AREA: DETACH ❑ATTACH S DWELLING UNITS: IS A SECOND UNIT ❑YES SECOND STORY []YES BEING ADDED? NO ADDITION? []NO PRE-APPLICATION ❑YES IF YES,PROVIDE COPY OF IS THE BLDG AN ❑YES , " " - "# y k 1 TOTAL VALUATION: PLANNING APPL# ❑NO PLANNING APPROVAL LETTER EICHLER HOME? ❑NO -•` '"' :.;? +rJ ovU biz ^' - By my signature below,I certify to each of the following: I am the property owner or authori ent perry owner's behalf. I have read this application and the information I h e provid is correct. I have read the Description of Work and itis accurate. I agree to comply with all applicable local ordinances and state laws relatin o uildin cons tru 'on. I au orize representatives of Cupertino to enter the above-i entified property for inspection purposes. Signature of Applicant/Agent: Date: f T— SUPPLEMENTAL INFORMATION.REQUIREDp �K f„ 'AOUTING'SI3P. _ r, New SFD or Multifamily dwellings: Apply for demolition permit fortIH�E�-CO TER s' D +BUr ILDING PLreOVER N ' ` RES IEYI existing building(s). Demolition permit is required prior to issuance of building U. tit permit for new building. `�" '" �„ � © IAY .Ei�PRS$ .r�`,r 1. P N>1TII�G PLAN REVIEW - Commercial Bldgs: Provide a completed Hazardous Materials Disclosure A``g , �rUsLLlamc'wo fo— rm ' if any Hazardous Materials are being used as part of this project. AKG ' {i II2E DEPT r _Copy of Planning Approval Letter or Meeting with Plahning prior to submittal of Building Permit application. �YsEWERnlsPx- ' B1dgApp_2011.doc revised 06/21/11 CITY OF CUPERTINO FEE ESTIMATOR-BUILDING DIVISION ADDRESS: 20663 CHERYL DR DATE: 04/11/2014 REVIEWED BY: MELISSA APN: 359 15 039 BP#: VALUATION: $20,000 PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration/ Repair PRIMARY SFD or Duplex PENTAMATION 1 R3SFDREM USE: p PERMIT TYPE: WORK REMODEL KITCHEN 132 S.F. & FAMILY ROOM AREA 192 S.F. . UPGRADE 100AMP PANEL TO SCOPE 200AMP PANEL, SAME LOCATION a Pfau Elec.Plan Check 0.0 hrs $0.00 P, Fee:1��>f rlrit Fee t'hrmi�. 11("-mit V�e. Elec.Permit Fee: IEPERMIT �Jr`tc> ' .'A" r � {Omer•1'larmb Irl'q" Other Elea Insp. 0.0 hrs $47.00 ` NOTE. This estimate does not include fees due to other Departments(Le.Planning,Public Works,Fire,Sanitary Sewer District,School District,etC). These fees are based on the prelimina information available and are onl an estimate. Contact the Dept for addn'1 info. FEE ITEMS (Fee Resolution 11-053 Eff 7/1/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 132 s.f. Remodel,Kitchen(<=300 sf) Suppl. PC Fee: (F) Reg. 0 OT 0.0 hrs $0.00 $626.00 1REMRESKIT PME Plan Check: $0.00 192 s.£ Remodel, Other Permit Fee: $0.00 $418.00 1 IRF MRESOTH Suppl. Insp. Fee.0 Reg. ® OT 0,0 hrs $0.00 200 amps Electrical PME Unit Fee: $0.00 $47.00 IBELEC200 Services PME Permit Fee: $47.00 Con:Sin.,cli«n I'�/X. Administrative Fee: IADMIN $44.00 0 Work Without Permit? 0 Yes (j) No $0.00 E) Advanced Planning Fee. $0.00 Select a Non-Residential 0 Travel Documentation Fee: 1TRAVDOC $47.00 Building or Structure , Strong Motion Fee: IBSEISMICR $2.00 Select an Administrative Item Bldg Stds Commission Fee: IBCBSC $1.00 `ySB �L $141.00 $1,091.00 TOTAL FEE: $1,232.00 MAIN Revised: 04/01/2014 d {' OWNER-BU[LDER DISCLOSURE FORM E COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION 10300 TORRE AVENUE• CUPERTINO,CA 95014-3255 CUPERTINO (408)777-3228• FAX(408)777-3333• buildinoCa cuoeTtino.org Dear Property Owner(s): An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified at: SIT-ADDRESS 06(o-6 CNCRY( DR-LvE I APN 15_ _ O BP= v o 0 t7/� 0ANER NA10E OWNER ADDRESS �vir1f10. '10ie art V 1omme 1 '206(,*?, DESCRIPTION OF WORK: ICI' Vke_.1 REMO EL We are providing you with an Owner-Builder Acknowledgment and Information Verification Form to make you aware of your responsibilities and possible risk you may incur by having this permit issued in your name as the Owner-Builder. We will not issue a building permit until you have read, initialed your understanding of each provision, signed, and returned this form to us at our official address indicated. An agent of the owner cannot execute this notice unless you,the property owner, obtain the prior approval of the permitting authority. OWNER'S ACKNOWLEDGMENT AND VERIFICATION OF INFORMATION (DIRECTIONS:Please read and initial each statement below to signify you understand or veriy this information.) K--1. I understand a frequent practice of unlicensed persons is to have the property owner obtain an "Owner- Builder"building permit that erroneously implies that the property owner is providing his or her own labor and material personally. I, as an Owner-Builder, may be held liable and subject to serious financial risk for any injuries sustained by an unlicensed person and his or her employees while working on my property. My homeowner's insurance may not provide coverage for those injuries. I am willfully acting as an Owner-Builder and am aware of the limits of my insurance coverage for injuries to workers on my property. 41-2. 1 understand building permits are not required to be signed by property.owners unless they are responsible for the construction and are not hiring a licensed Contractor to assume this responsibility. 3. I understand as an"Owner-Builder" I am the responsible party of record on the permit. l understand that l may protect myself from potential financial risk by hiring a licensed Contractor and having the permit filed in his or her name instead of my own. _2� 4. 1 understand Contractors are required by law to be licensed and bonded in California and to list their license numbers on permits and contracts. � 5. i.understand if I employ or otheRt&e engage any persons, other than California licensed Contractors, and the total value of my construction is at least five hundred dollars ($500), including labor and materials, I may be considered an "employer"under state and federal law. %6. 1 understand if I am considered an "employer" under state and federal law, I must register with the state and federal government,withhold payroll taxes, provide workers' compensation disability insurance, and contribute to unemployment compensation for each"employee." I also understand my failure to abide by these laws may subject me to serious financial risk. �7. i understand under California Contractors' State License Law, an Owner-Builder who builds single-family residential structures cannot legally build them with the intent to offer them for sale, unless all work is performed by licensed subcontractors and the number of structures does not exceed four within any calendar year, or all of the work is performed under contract with a licensed general building Contractor. 04-8. 1 understand as an Owner-Builder if I sell the property for which this permit is issued, I may be held liable for any financial or personal injuries sustained by any subsequent owner(s)that result from any latent construction defects in the workmanship or materials. Oia,7ieiBuilde7Fo7-77i2010.doc remised 04/14110 f Wg: I understand I may o.btain.more information regarding my obligations as an "employer"from the Internal Revenue Service,the United States Small Business Administration,the California Department of Benefit Payments, and the California Division of Industrial Accidents. I also understand I may contact the California Contractors' State License Board (CSLB) at 1-800-321-CSLB (2752) or v✓ww.cslb.ca.gov for more information about licensed contractors, °r 10. l am aware of and consent to an Owner-Builder building permit applied for in my name, and understand that I am the party legally and financially responsible for proposed construction activity at the site address listed above. 11. 1 agree that, as the party legally and financially responsible for this proposed construction activity, I will abide " by all applicable laws and requirements that govern Owner-Builders as well as employers. ):3(--12. 1 agree to notify the issuer of this form immediately of any additions, deletions, or changes to any of the information I have provided on this form. Licensed contractors are regulated by laws designed to protect the public. If you contract with someone who does not have a license, the Contractors' State License Board may be unable to assist you with any financial loss you may sustain as a result of a complaint. Your only remedy against unlicensed Contractors may be in civil court. It is also important for you to understand that if an unlicensed Contractor or employee of that individual or firm is injured while working on your property, you may be held liable for damages. If you obtain a permit as Owner-Builder and wish to hire Contractors, you will be responsible for verifying whether or not those Contractors are properly licensed and the status of their workers' compensation insurance coverage. CONSTRUCTION LENDING AGENCY (DIRECTIONS:Please complete the following construction lending agency information.) I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097 Civ.) Lender Name: Lender Address: Before a building permit can be issued,this form must be completed and signed by the property owner and returned to the agency responsible for issuing the permit. Note:A copy of the property owner's driver's license, form notarization, or other verification accetable to the city maybe required to be presented when the permit is issued to vert the property owner's si atu e. Property Owner's Signature: Date: 4 fit2os --------------------------------------------------------------------------------------------------------------------------------------------- (NOTE: The following Authorization Form is required to be completed by the property owner only when designating an agent of the property owner to apply for a construction permit for the Owner-Builder). AUTHORIZATEON OF AGENT TO ACT ON PROPERTY OWNER'S BEHALF Excluding the Notice to Property Owner,the execution of which I understand is my personal responsibility, I hereby authorize the following person(s)to act as my agents)to apply for, sign, and file the documents necessary to obtain an Owner-Builder Permit for my project. Scope of Construction Project(or Description of Work): KTT CtE�1 1E:"0DQ_ Project Location or Address: 20(o(o3 CAEo4�_-I)RMVE Cupe,rf;wo , LA g5(AA Name of Authorized Agent: sy-s7mi)m V,.( oe Tel No (t&)G65-4,41 Address of Authorized Agent: 141q Yor►_ PAVE CPrynpbeli, �� Q�DOR I declare under penalty of perjury that I am the property owner for the address listed above and 1 personally filled out the above information and certify its accuracy. Note:A copy of the property owner's driver's license, form notarization, or other verification acceptable to the city may be required to be presented when the permit is issued to verify the property owner's signature. Property Owner's Signature: Date: 111I1UI4 0vv;7erBLi1de7Fo1-77: 2010.doe revised 04114/10 April 9 2014 To whom it may concern: We (Donna Yongdong Dionne and Joseph Marcel Dionne) grant permission to Skender Kraja to act as our agent to obtain a owner/builder permit on our behalf for our kitchen remodel, electrical panel upgrade along with removal of fireplace insert. Please see attached plans for approval. Our home address is: 20663 Cheryl Dr. Cupertino, CA 95014 If you have any further questions please do not hesitate to call either of us at: Donna Yongdong Dionne(408) 831-8728 Joseph Marcel Dionne (408) 250-6226 Thank you, 0 Donna Yongdong Dionne Joseph Marcel Dionne �i Building Department City Of Cupertino 10300 Torre Avenue Cupertino, CA 95014-3255 Telephone: 408-777-3228 C U P E RT I N O Fax: 408-777-3333 CONTRACTOR/ SUBCONTRACTOR LIST JOB ADDRESS: ZQ L PERMIT# qovv_ OWNER'S NAME: N PHONE# A —128 GENERAL CONTRACTOR: BUSINESS LICENSE# ADDRESS: CITY/ZIPCODE: *Our municipal code requires all businesses working in the city to have a City of Cupertino business license. NO BUILDING FINAL OR FINAL OCCUPANCY INSPECTION(S) WILL .BE SCHEDULED UNTIL THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS HAVE OBTAINED A CITY OF CUPERTINO BUSINESS LICENSE. I am not using any subcontractors: Signature Date Please check applicable subcontractors and complete the following information: t/ SUBCONTRACTOR BUSINESS NAME BUSINESS LICENSE # Cabinets & Millwork Cement Finishing Electrical Excavation Fencing Flooring/ Carpeting Linoleum/Wood Glass/Glazing Heating Insulation Landscaping Lathing Masonry Painting/Wallpaper Paving Plastering Plumbing Roofing Septic Tank Sheet Metal Sheet Rock Tile Owner>Contractor Signature Date COK �1! TY 1� �P`M. "IT[17-PARTMENT MBOIJO BULDIiNG C'ji-ERTINO 0 N N E , RES � D E N C E investments D This-gat of plans and spec ficat!onc IMUST be kept at the Design oo -,Jnsvu�tm icn. It is unlakvful to ar -rCHF-N Re any or adt',arations oil same,or to devia"e Widloul approval from the Building Official. 20663 CHIPYL PP-W[� ('I NO, CALIFOPNIA 9-�501-4 Th- of this plan Fnd tions SHALL NOT P, ji_ a C0 0 e Violation ft E tate Law. PCN, ti- THE C6NFPAL,CONTRACTOR 5HOLLV V151ITHE!5I1E TO FAMILIARIZE THEMSELVES W1 THE 5C011e OF WORK&POUAL CON191"ION5 PRIORTO5U13MI7-nN6 THEIR PIP, NO CON5112ERA-`ION FOR EXTRA PAYMENT WILL BE MAVe POP ITEMS THAT COULD PF 12MkMINet7 A5 NECF55AIZY MATERIALS OR-,A0O1Z FROM SUCH A V1511-. 2.ALL CON5TRUCT1ON AND MATERIALS SHALL BE A5 5MCIFIE12 ANP/OR eQUIMP BY THE APOFE12 fV11ON Or THE CALIFORNIA BUILDING COPE ANI?ALL LOCAL COPF5 ANP AUTHORITIES. THE GENERAL CONTRACTOR 51ALL,\/r.RIPY ALL.t?rMFN51ON5 ANP RITE CONDI-1`101\15 PRIOR TO COMMENCING ANY WORK.tHr GENERALCONTP-r-*(OR SHALLNOTIFY--HF PROJECT SHALL COMPLY WITH: 12E516NFIZ OF ANY 1215OFFrANCY IN THESE FLANS&5rrC1FICA-n0N5. ADN: 4.THE CONTRACTOR SHALL CONFINE OPERATIONS AT THE 5I7r10 AMA5 PERMITTED BY CALPOIMIA 3JILPIN6 COM EDITION gRItN aA5e CODE 2009 10C) LAW,ORPINMCF5,I'Vil ANP THE CONTRACT POCUM N75,ANP 51 1-NOr CALIFORNIA MECHANICAL COOS EDITION jjC�MC M5TIN6 Lrf: 51NCU�FAMILY HOW UNMA50NAPLY FNCUMPFZ THE 51TE WITH ANY MAIVZIA,5 OR EQUIPMENT. CALIFORNIA FILMPIN6 COVE EPITION Y aQWLFC ZONING: CALIFORNIA Fl_ NTRICAL Com E111110NZr�OF LO'r: 7,092 5F 5.5HOLLP AN FWOR APPEAR IN SPEC.OR DRAWINGS.OR IN WOW PONE BY OTI-Ir5l�5 CALIFORNIAENERGY COM Fr"ON�f�UlCll;lNlENERGY E�.FPICIE�NCY51-A�,VA-V507plp 4!rAF-jW?jP AFFECTING TI-115 WORK,N011FY THE t9r516NI�R M THE OWNER AT ONCE FOR CALIFORNIA M5t9E!Nn&COM EDITION 1ION (2009 IFC) YEAR BUILT: 1965 IN5TRLkl-nON5 A5-70 FRC)GrWLA�.IF CONTRACTOR IIIZCCMt?5 WITH WORK AFPrCTrV CALIFORNIA HIM CODE E�tqCN 27�_ I,C u OF5TORIV5: it WITHOUT INSTRUCTIONS FROM THE M516NFIZ/OWNIM.THE CONTIZAC-1101Z 5KALL.MAKE FLOOR AREA OF 5TRILICTILIM: C400V ANY M51-11-nNO PAMALAF OR VFI`ECr. EM5TING RESIDENCE: 6.CONSTRUCTION 1-1,4011-IrY:CON5TRUC'nON CONTRACTOR ANP H15 5LVCONTR, A6Wr THA-r IN ACCORDANCE WITH CiFNEMI-Y ACaMP CON5TRUCnON I1PAC'nCr5, CON51'RLL111ON CONTRACTOR ANP H15 51,1000NTPACTOR WILL PE REQUIRED TO W 0 APPLICABLE CODES : rM51NCI LIVING SPACE 1.735.3 SOFT A55UME 50Lr AND COMFLM M5FON5IPII-I-rY FOR JOB 517r CONPMON5 PWINC4 THE COW%OF CONSTRUCTION Or THE FRO-ECT,INCL.5AFETY Or ALL MR5ON5 > ANP FROPEIZITY.TH15 REQUIREMENT SHALL OF MAPF TO APPLY CON-nNLIOU5LY&NOT iT/ C.-V6V 483 50"r LIMITED TO NORMAL WORKING HOW5.CON5TRUG1JON CONTRACTOR ANP 5UPCONTR. fl< MMOPE�L.OF KlF�N ANO FAMILY ROOM SOFT I`Uk'MER ACME.-rO 17V.Fr�Nt?,INP�MNIFY ANr2 HOILI:2 P�-516N rROFE55IONAL5 HARMI-15555 DEMO Or(V.)HIM P AC�IN FAMILY ROOM FROM ANY ANP A-IL LIA011-ITY,MAL OR A-1-F6Ft?,IN CONNE��CVON WITH 11�1� Z./ REPLACING(5)I00LAMP5 E�IF�Ci"RIC&PANEL WTH NEW 200 AMP r�!-�CTIZICA,PANEL P60-OlZMANCe OF WOW,ON TH15 I`ROJ15�0r, LPC �11 1�3 IL ELECTRICAL 4RAM5 rT`CHEN/FAMILY ROOM MOM AREA VA1110: 7,592 5F-29 X 7. PROV[Pr ALL NFCE55Ak'Y BLOCKING,PACKING ANP FRAMING FOR 1-16Hr FIXTUM5 ANP ALL,OTHER nM5 MQUIRIN6 THE 5AME�, SLOPE Al BUILDING SITE: LEVEL ALL THE GENERAL CONTF,-L'rOIZ SHALL MAINTAIN THE JOB 517E IN A CLEAN,OIZPFla-Y z CONPMON FIMV OF t2ePIZ15 ANP LITTER.EACH 5LOCONTPACTOR IMMVPIATLY LFON OCCLIPAK�-Y CROW: COMPLETION OF EACH PHASE Or THEIR WORK SHALLW-MOVE�ALL TIZA51-1 ANP PrPR15 \Z SCOPE OF WO RK IZ-3 FOR M51MIKICE A5 A M51,11-r Or THEIR OP`V2 11ON5. U rOR6AQAaAk 9.CONTRACTOR SHALL N(7r SCALEPlMeN51ON5 FROM OP-AWN65.FOLLOW WRITTEN S I 41111111111111,� T E DIMENSIONS ONLY TYPE Or CON51RIJCTION:VP 10ALL FAMHIN6&REPAIRINGREPAIRINGANP REPLACING Or MATFIRLAL5 ANP 5WFACV5 CUT OR VAMA6FI:9 IN EXrClLlflON Or WOW,SHALL-M POM WITH APPLICABLEAPPLICABLEMATERIALS 50 111 'MAT5UT-ACF5 MPLACeP WILLWILLMATCH 5WIZOUNVIN6 51MILAZ 5WFACI55 LFON I'OrA,LINEAL PMT: COMPLETION.COMPLETION.20663CHERYL MW,CLFE!kflNO.CA 99014 EW51'IN0.!�MROIQ IWAL�5: 11■ . CON5T]ZLLITION 5QU.ONLY VIP PERFORMEDVWINC4 FOLLOWING HOUIZ5: C EM5"Imci.EXTERIOR WALLS 10 M MMOL115MV: P:R OWNER; JJOSEPHPONNA VICNNV MO.-FR. I AM-6 PM MPOLIO lN\/r5VWW5&M516N 5A, 8 AM-5 I'M M#gc"l*r M00LOMDCU0 cherL41 t2r 5M. NOAC-nVI1YA-LOMt? CFM-.- PROPOSED SETBACKS: ONE!LEVEL(FIT) rM UPERTINO 1217 COUNTRY 5aUIM COWr.5APArOCA CA 950700 446-2441 PROW 20 APR I 51112V(Ri6l'to 5 12014 10 151va(LFrT) sooding Depsibnent 10. MAR GENER J S ADD 20% 5QUAM FVPf AND MRCeNfOr IMPtWOU5 517E COVERAGE: EXISTING IMIMVIOU5 NIV COVERAGE: REVIEWED FOR CODE COMPLIANCE (ED RESIDENCE: 2.2153 SF 2'9% '/� Reviewed BY GENERAL DRIVE/WALK WAY: 766 5F lox '/- ARCHI1FCTL3ZAI-! (ED PATIO/WALK: 1,985,5r 21Y.I/- A 1.0 TITLE 5HFFT,6FNFrAI-INFORMA-nON INFORMATION TOTAL: 4,553 5F 607-11- A 2.0 (E) FLOOR PLAN/ PPMOILITION,-EC4FNP,SCHEMATIC PIA61ZAM All on AZI r.Ni-APCFL?Kl-rCHE�N,NOM5,5YM[3(2,5 AS SHOWN AMA5 OF MMOMI� CE-11-11\16 r1LAN5 APRIL - 2014 UFFICE COP' i ' ' I KITCHEN/FAMILY ROOM324-ft er M M TM N. vnactt (408) 446-2441 PROJECT DIRECTORY GENERAL INFORMATION VICINITY MAP SHEET INDEX A U MBOUO Investments BED ROOM 1 Design (E) GARAGE ENTRANCE 1D see enlarged kitchen/family room plan on sheet A2.1 for more info ® remove existing laminate floor and install new wood floor 0 to match (e) oak floor demo (e) wood paneling, close wall and finish to match (e) upgrade (e) 100 AMP electrical panel to 200 AMP US HALLWAY demo (e) fire place and close up wall, match (e) BATH 0 © refrigorator C= O wall oven/microwave combination Oj ® hood and stove LIVING ROOM } STORAGE demo kitchen O zw F_ , 11 (E) sink U O Q ?. (E) dishwasher E) KITCHEN I ml (E) FAMILY ROOM z' ! © I I CS DINING KEY NOTES - 1. FLOOR 1 z o w o o > � EXISTING FIRST FLOOR �, z z � ......... ......... ........ '�Q) Q (e) roof access, storage W OZ . � z cv I NO CHANGES OR UPDATES TO SECOND FLOOR z I � I C U I — I 0 I I I I i I I i I BATH I KEY NOTES - 2. FLOOR 2 HALLWAY BATH CLOSET I I I CUPERTINO (E). SPACE ACCESS Department EXISTING o ® � �� FLOOR PLANS'md ACCE MASTER I BED ROOM 2 BED ROOM 3 - o PZ�YI- Fk;W (DR 140D ����L���C� � (E) IIC(rYIGWGU By APRIL— 2014 aK ar wrc.er DEMO (E) WALL MM IEL.Ne PFWECi ROOF OVERHANG (408) 446-2441 ® ((NE)) pARBONATTERY MONOXIIDEC DEPTECTOR EXISTING SECOND FLOOR ® � 14ESMOKE D W/BADTTERYTBACKUO APPROVED, 110V HARD EXISTING FLOOR PLANS 1/4" 5 SYMBOLS 3 A °U 3'-4' ki� 3'-2' •_6' 3'-6' 1l'-1' MBOUO 1O new 36" counter depth refrigorator I n ve s t m e n t s 15 STORAGE 0 O 02 30" woll oven/microwave combination Design t O3 finish wall to match (e) s 324 SCS I t ® new pendant lights 3'-s• � 36" new hood and stove �9 30" double sink 71-6 21 10 24" new dishwasher ® 11 adjust mechanical outlet if necessary (N) KITCHEN2s,6' © the backsplash, built-in microwave C4 14 lazy susan cabinet 1^1 15 pantry cabinet 2'-6" DINING O B �l D FFAMILY ROOM 1B new undercabinet flourescent light fixture prep and paint wall with semi-gloss point L1® 110 VOLT OUTLET WITH GFI, GROUNDED A 19 (e) light switch FT14 9 14 © (newslwooderfloor switch 11 1 matches (e) oak floor ® ® closed wall and finished to match (e) W LiJ O 0 NEW ENLARGED KITCHEN FLOOR PLAN 1/2" 3 KEY NOTES 1 cry nz w Zoo o ,v � QU— 3-4' Ill O :71 SOF 3'-4' Q U 1.8 0 1 67' 0 -- -- _ 3,-1• - -c -D- CUPERTINO Building Department ENLARGED 1, APR 1 1 2014 KITCHEN ® REVIEVVED FOR WDE COMPLIANCE to. la , ©. a a o Reviewed By � h 'J�c''� APRIL- 2014 lEl He PftWECf O Q (408) 446-2441 _g_ _A_ A - 21 INTERIOR ELEVATIONS 1/2" 2 o- !�SMOKE DETECTOR CBC 907.2.10 —SHALL BE INSTALLED IN ACCORD. W/ MANUF. USING 2 Q remove (e) ceiling fan/light —SHALL BE MOUNTED ON THE CLG. OR AREA GIVEN Q demo (e) flourescent light cover and drop ceiling M B 0 U 0 WITHIN THE UNIT O (2 ALL 125 VOLT SINGLE PHASE 15 & 20 AMP RECEPTICLES INSTALLED 3 (e) electr. connection for oven & microwave WITHIN 6' OF WET SURFACE SHALL BE GROUND FAULT CIRCUIT ® demo (e) fire place vents Investments INTERRUPTED (GFI) CEC 210.12 Q3 ALL LIGHTING BOTH INTERIOR OR EXTERIOR TO COMPLY WITH Q5 replace or repair (e) smoke detector, TITLE-24 REQUIREMENTSDesign .g © demo (e) tv connection, finish wall ®ALL BRANCH CIRCUITS THAT SUPPLYING RECEPTACLES IN BED ROOM 1 2 (E) GARAGE Q7 relocate (e) electrical plug FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, ENTRANCE LICRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS AND SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED ARC—FAULT CIRCUIT INTERRUPTER [� $ �2 (AFCI) (CEC 210.12 (B)) 05 ALL 110 VOLT, SINGLE PHASE RECEPTACLE OUTLETS SHALL HAVE ALL (E) - 1. FLOOR 1 GROUND—FAULT CIRCUIT PROTECTION AT THESE LOCATIONS: BATHROOMS, OUTSIDE, GARAGE, WITHIN 6' OF ANY SINK "' ©PROVIDE LIFER OR OTHER APPROVED GROUND PER CEC 250. +A __ HALLWAY +A� - - BATH "�' O new electrical panel 200 AMP Q7 LUMINARIES W/ MODULAR COMP. THAT ALLOW CONVER, FROM SCREW—BASED WIRING ARE NOT CONSIDERED HIGH EFFICIENCY LIGHTING. ��� , O install new recessed lights, LED 0 3e ELECTRICAL BOXES OF ANY MATERIALS LOCATED THROUGH RATED WALL O (e) electr. connection for oven & microwave ®LOCATED BETWEEN GARAGE & DWELLING SHALL BE LISTED AND TESTEDLIVING ROOM o a $ ® (N) UNDER CABINET LIGHT FOR USE IN FIRE—RESISTANCE RATED ASSEMLIES AND INSTALLED STORAGE 5® 3 2 w �2 IN ACCORDANCE WITH THE INSTRUCTIONS INCL. IN THE LISTED n (-- - O ) smoke detector, PER CBC 712.3.2. z (E) KITCHEN i .._ .... © not used 09 NOTE FOR LIGHTING IN BATHROOMS, GARAGES, LAUNDARY AREAS: _ --' O ALL LIGHT FIXTURES SHALL BE EITHER HIGH EFFICANCY (FLUORESCENT) O +I 7 not used OR SHALL BE CONTROLLED BY A MANUAL—ON OCCUPANT SENSOR. z !I ® not used AN APPROVED OCCUPANT SENSOR DOES NOT ALLOW THE LIGHT TO BE TURNED ON AUTOMATICALLY AND DOES NOT HAVE AN OVERRIDE Q' .I, O Qg not used THAT ALLOWS IT TO REMAIN ON. I ! (E) FAMILY ROOM 1® new pendant light fixture, by owner 1�UPGRADE ELECTRICAL PANEL BY LICENSED ELECTR. CONTRACTOR T 4 11 NEW VENT FOR HOOD THROUGH WALL, BY CODE w e' (E) DINING I ! I ,1 0 1© new tv connection AT PRESENT COMPACT FLUORESCENT LAMPS OPERATED BY ELECTORIC BALLAST 2-9 1 11 HAVE FOUR—PIN BASES. ® (O 2 e 1© relocated electr. plug, GFI, grounded � 1©ALL FLOURESCENT LAMPS W/ 13 WATTS ORE MORE SHALL HAVE ELECTR. BALLAST o ' ( .T�2 '�$ 1® updated electr. plug, GFI, grounded z �- OCC. SENSORS THAT HAVE MIN. LOAD REQUIREMENTS TYP. DO NOT HAVE A GROUND (O (E) © 1® not used I� WIRE THOSE DO NOT HAVE A MIN. LOAD REQUIR. DO HAVE A GROUND WIRE. O go sparse ���o-rAA: (E) CEILING FIRST FLOOR 1® (N) ELECTR. CONNECTION GROUNDED for refrigerator Q TITLE 24 RESIDENTIAL LIGHTING MEASURES: i© (N) SINK ER COR n Q 1 (N) ELECTR. CONNECTION FOR STOVE/ (f-) z ALL PERMANENTLY INSTALLED HIGH EFFICACY LUMINAIRES SHALL BE ® HOOD, GROUNDED z e SWITCHED SEPARATELY FROM LOW EFFICACY LUMINAIRES. (150 (K) (8)) W O S Q) ©PERMANENTLY INSTALLED LIGHTING IN KITCHENS SHALL BE HIGH Q V EFFICIACY LUMINAIRES. UP TO 50 % OF THE WATTAGE OF PERMANENTLY INSTALLED LIGHTINGIN8))KITCHENS MAY BE IN LIGHTS THAT ARE NOT HIGH KEY NOTES (N)— 1. FLOOR 2 EFF 0 V I'lumb�ng 5umbols 1 7- GENERAL GENERAL NOTES FOR MINIMUMS: S Cal?WA9E Z N A MIN. OF 20 AMP SMALL APPLIANCE BRANCH CIRCUITS SHALL BE G fiDfNA1E2 $ LIGHT SWITCH z PROVIDED FOR ALL RECEPTACLE OUTLETS IN THE KITCHEN, DIMGTWA59 � $ TWO POLE LIGHT SWITCH W/ DIMMER � DINING ROOM, PANTRY, OR OTHER SIMILAR AREAS. (CEC 210.11 (C) (1)) O V Q IN EVERY DWELLING UNIT, FIXED APPLIANCES SUCH AS FOOD WASTE GRINDERS, 13 RECESSED FLUORESCENT LIGHT FIXTURE DISHWASHERS, WASHING MACHINES, DRYERS, LAUNDRY TRAY LOCATIONS, 6 (N) WALL MOUNTED FLUORESCENT LIGHT FIXTURE W/ COMBO, BUILT—IN REFRIGERATORS OR FREEZERS, FURNACES, AC UNITS. PHOTO/MOTION SENSOR CONTROLLED (TYP.) Q3 COUNTERTOPS IN KITCHENS, PANTRIES, BREAKFAST ROOMS, DINGING ROOMS a McbwP 110 VOLT WATER PROOF OUTLET WITH GFI AND SIMILAR AREAS, SPACES 12 INCHES OR WIDER SHALL HAVE RECEPTACLES BED ROOM 1 (E) GARAGE 0Fl6 110 VOLT OUTLET WITH GFI, GROUNDED INSTALLED SUCH THAT NO POINT ALONG THE WALL IS MORE THAN 2 FEET ENTRANCE FROM A RECEPTACLE. (CEC 210.52 (C) (1)) J1 110 VOLT OUTLET ®ALL RECEPTACLES IN BATHROOMS, GARAGES, ACCESSORY BUILDINGS, OUTDOORS, O 10 WALL MOUNTED FLUORESCENT LIGHT FIXTURE CRAWL SPACES, UNFINISHED BASEMENTS, KITCHENS (WHERE RECEPTACLES SERVE , ® $ T TELEPHONE OUTLET COUNTER TOP SURFACES), LAUNDRY, UTILITY, WET BAR SINKS (WITHIN 6 FEET OF 0 TELEVISION ANTENNA JACK ®8" ABOVE FLOOR THE EDGE OF THE SINK), SHALL HAVE GROUND—FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION. (CEC 210.8). ( (E) WALL MOUNTED FLUORESCENT LIGHT FIXTURE W/COMBO. IN ALL AREAS SPECED IN O RECEPTACLES SHALLFIBE LISTED TAMPER RESISTANALL 125 T RECEPTACLES. (CEC 406.11) ®© I �E) PHOTO/MOTION SENSOR CONTROLLED (TYP.) HALLWAY d -0� INTERNET CONNECTION �'g { $Z TWO WAY LIO}7vVf#: UpERTINO 010 0 — IP 110 VOLT OU U11ding Daps.;,�,,w 5® 1 (NXN) 3 . :a 1 ® nt CARBON MON ECTOR u,1t7 STORAGE (Nl WIRED W/BATKU� ELECTRICAL w �2 n z (E) KITCHEN a ® SMOKE DETE, 0 APPROVE�j VfA Dig {{a _4 7 I I ® WIRED W/BA CKUP 'P , 2014 FLOOR PLANS = 1 41� HANGING/CEILING MOUNTED FLUORESCENT LIGHT FIXTURE (E) CRAWL SPACE ACCESS (N) t $ TWO POLE LI(S �SVft/ t36° 'fR (,FIJLJRE COMPLIANCE F1 i G) 1 RECESSED EXHAUST FAN, SWITCH CONTROLLED sc°c Q — — 2 k'i 2 E) FAMILY ROOM (E) ATTIC ACCESS NEcnetE TELEV SION CABLE f � i3 GQ � f APRIL— 2014 CEILING FAN/ LIGHT COMB, _ — (N) INTERIOR/EXTERIOR WALL 4N�. 4 26 a� MMS ( o 2�$ �.. :.._ I ®MECHANICAL RETURN © (E) EXTERIOR WALLL. oaacM �(E) 11 �(E) MECHANICAL CEILING REGISTER SUPPLY (408) 446-2441 o (E) INTERIOR WALL } --------------- ROOF OVERHANG (N) CEILING FIRST FL00 El O thermostatSECUITY EM {) RECESSED EXHAUST FAN/ LIGHT COMB., SWITCH CONTROLLED ELECTRICAL FLOOR PLANS 1/411 5 SYMBOLS 3 E - 1