14060033 CITY OF CUPERTINO BUILDING PERMIT BUILDING ADDRESS: 22126 LINDA VISTA PL CONTRACTOR:SLINGSHOT POWER INC PERMIT NO: 14060033 OWNER'S NAME: KU MARTIN 164 MAIN ST DATE ISSUED:06/06/2014 OWNER'S PHONE: 4085689556 LOS ALTOS,CA 94022 PHONE NO:(650)308-9055 LICENSED CONTRACTOR'S DECLARATION JOB DESCRIPTION:RESIDENTIAL COMMERCIAL E] INSTALL(N)EV CHARGING STATION IN GARAGE License Class_ Lic.# (CLEAR �� �S� Q'p�►'��DateICE 20' X 20' TO BE MAINTAINED) Contractor I hereby affirm that I am licensed under the provisions of Chapter 9 (commencing with Section 7000)of Division 3 of the Business&Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self-insure for Worker's Compensation,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this permit is issued. Sq.Ft Floor Area: Valuation:$1000 I have and will maintain Worker's Compensation Insurance,as provided for by Section 3700 of the Labor Code,for the performance of the work for which this APN Number:35608011 00 Occupancy Type: permit is issued. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is PERMIT EXPIRES IF WORK IS NOT STARTED correct.I agree to comply with all city,and county ordinances and state laws relating WITHIN 180 DAYS O T ISSUANCE OR to building construction,and hereby authorize representatives of this city to enter FU LED INSPECTI upon the above mentioned property for inspection purposes. (We)agree to save 180 D indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the b , ate. granting of this permit. Additionally,the applicant understands and will comply with all non-point sou regulations per the Cupertino Municipal Code,Section 9 18. L RE ROOFS: Signature Date v All roofs shall be inspected prior to any roofing material being installed.If a roof is installed without first obtaining an inspection,I agree to remove all new materials for inspection. OWNER-BUILDER DECLARATION Signature of Applicant: Date: I hereby affirm that I am exempt from the Contractor's License Law for one of the following two reasons: ALL ROOF COVERINGS TO BE CLASS"A"OR BETTER I,as owner of the property,or my employees with wages as their sole compensation, will do the work,and the structure is not intended or offered for sale(Sec.7044, Business&Professions Code) I,as owner of the property,am exclusively contracting with licensed contractors to HAZARDOUS MATERIALS DISCLOSURE construct the project(Sec.7044,Business&Professions Code). I have read the hazardous materials requirements under Chapter 6.95 of the California Health&Safety Code,Sections 25505,25533,and 25534. I will I hereby affirm under penalty of perjury one of the following three maintain compliance with the Cupertino Municipal Code,Chapter 9.12 and the declarations: Health&Safety Code,Section 25532(a)should I store or handle hazardous I have and will maintain a Certificate of Consent to self-insure for Worker's material. Additionally,should I use equipment or devices which emit hazardous Compensation,as provided for by Section 3700 of the Labor Code,for the air contaminants as defined by the Bay Area Air Quality Management District I performance of the work for which this permit is issued. will maintain compliance with the Cuperti Municipal Code,Chapter 9.12 and the Health&Safety Code,Sections 2550 533 and 25534. I have and will maintain Worker's Compensation Insurance,as provided for by P Section 3700 of the Labor Code,for the performance of the work for which this Owner or authorized agent: Date: 1� permit is issued. I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Worker's CONSTRUCTION LENDING AGENCY Compensation laws of California. If,after making this certificate of exemption,I become subject to the Worker's Compensation provisions of the Labor Code,I must I hereby affirm that there is a construction lending agency for the performance of forthwith comply with such provisions or this permit shall be deemed revoked. work's for which this permit is issued(Sec.3097,Civ C) Lender's Name APPLICANT CERTIFICATION Lender's Address I certify that I have read this application and state that the above information is correct.I agree to comply with all city and county ordinances and state laws relating to building construction,and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes.(We)agree to save ARCHITECT'S DECLARATION indemnify and keep harmless the City of Cupertino against liabilities,judgments, costs,and expenses which may accrue against said City in consequence of the I understand my plans shall be used as public records. granting of this permit.Additionally,the applicant understands and will comply with all non-point source regulations per the Cupertino Municipal Code,Section Licensed Professional 9 18. Signature Date . _.... ..... ._....... ALTERNATIVE ENERGY PERMIT APPLICATION "I COMMUNITY DEVELOPMENT DEPARTMENT•BUILDING DIVISION VJO 10300 TORRE AVENUE•CUPERTINO,CA 95014-3255 CUPERTINO (408)777-3228• FAX(408)777-3333•building(�cupertino.org PROJECT ADDRESS ,j V�Q(�, Q Lh(x t APN# nI���ttts OWNERNAME f�11M�y� {� -v V f\ `PHONEE j�Q. 6`/��I EMAIL STREET ADDRESS `l�\\ ` Q A `�/,�A (j L CITY,STATE,ZIP u o � FAX CONTACT NAME 366 ,j Q ('�`` ` PHONE I (Q:7 )3 E-MAIL�(J/9C I�-J/5�-V e.& A STREET ADDRESS L(�() /` �O y�J CITY,STATE,ZIP�/�J�(A C"I ('A '(F\AX J L-1 U t ❑ OWNER ❑ ..'.OIWNWNEOWNER-BUILDER ❑ OWNER AGENT ❑ CONTRACTOR CONTRACT/O/R[-AGENT ❑ ARCHr1E�cT' l❑ENGINEER ❑ DEVELOPER ❑TENANT 1. CONTRACTOR NAME 1 ,_ ( \�,,,� (_y� LICENSE NUMBERC II Q Q LICENSE TYPE BUS.LIC# 2 S , COMPANY NAME C LL.-V 1 7 u\ E-MAIL r. `j 1)K` o I J C,\�,.��O�I (0 FAX J STREET ADDRESS 1�1.wd1.�y-� L� CITY,STATE,ZIP PHONE ARCHITECT/ENGINEERNAME / LICENSENUMBER �-1 BUS.LIC`J#/Vot COMPANY NAME E-MAIL FAX STREET ADDRESS CITY,STATE,ZIP PHONE USE OF `kSFD or Duplex ❑ Multi-Family PROJECT IN WILDLAND PROJECT IN STRUCTURE: ❑ Commercial URBAN INTERFACE AREA ❑ Yes V No FLOOD ZONE ❑ Yes ❑ No ❑ SOLAR PANELS ELECTRIC VEHICLE CHARGING STATION 1 ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: KILOWATTS(COMMERCIAL ONLY): TOTAL VALUATION: DESCRIPTION OF WORK � Y By my signature below,I certify to each of a following: I am the property owner or authorized agent to act on the property ave read this application and the information I have provi d is correct. I have read the Description of Work and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating to b ' on. I authorize representatives of Cupertino to enter the aboLLv ide 'fled property for inspection purposes. Signature ofApplicant/Age Date: v f 14 PLEMENTAL INFORMATION REQUIRED p �� ` • ,O,FFjCEZ15EONLY ;_.��;. a r� �� OYER�T�L-COiINTEit� - EXPRES� s�� v PVApp 2011.doc revised 03116111 CITY OF CUPERTINO FEE ESTIMATOR-BUILDING DIVISION ADDRESS: 22126 LINDA VISTA PL DATE: 06/06/2014 REVIEWED BY: MELISSA APN: 326 08 011 BP#: *VALUATION: 1$1,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Alteration / Repair PRIMARY SFD or Du lex PENTAMATION SOLAR-RES USE: p PERMIT TYPE: WORK INSTAL N EV CHARGING STATION IN GARAGE CLEAR 20'X 20'TO BE MAINTAINED SCOPE Ja ma Plan Check 1111vnh. Plan(.hcl:k 11er.1's<att C`1>ee t7c>c, . I'er,st,t Fee.- Plumb. F'erm7l7,eU: 1:.'ac:. 1'<rsrri ,c;,. „ FkchlrsnLj Other Piumb fnsp. 01her I?s1-3. from. 1'e,:: Tlwnb. hvrr .Tee: I lec. Ins,'), 1i>c. NOTE:This estimate does not include fees due to other Departments(Le.Planning,Public Works,Fire,Sanitary Sewer District,School District,etc). Theseo. -fees are based on the relimina information available and are onl an estimate. Contact the De t or addn7 in FEE ITEMS (Fee Resolution 11-053 Eff. 7/1/13) FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 0 # Alternative Energy System Suppl. PC Fee: (j) Reg. Q OT 1 0.0 1 hrs $0.00 $229.00 1PHOTOVRES Photovoltaic System PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Feer Reg. 0 OT0,0 hrs $0.00 PME Unit Fee: $0.00 PME Permit Fee: $0.00 Consirl.1ch.On Tux: ,(:llnrrzi�iraiive 1'ac: 0 Work Without Permit? ® Yes 0 No $0.00 E) Advanced Planning Fee: $0.00 Select a Non-Residential E) Building or Structure 0 �1"il,'£>7 r�itfC,'i.ftt'!.e' 21d.�11frY1 I`L'.E?5': � Strong Motion Fee: 1BSEISMICR $0.50 Select an Administrative Item Bldg Stds Commission.Fee: 1BCBSC $1.00 Q u $1.50 $229.00 ` TOTAL FEE: $230.50 Revised: 04/01/2014 Sheet Index ✓`'�\���� �W ���'� N����N �� l 1...Title,Index,and EV Quipment Mounting Location s � S2...Load Calculations&EV Charger Circuit Schematic �� lv' ` 1' JJ h- at 3...General Notes 4...Electrical Notes C:wri Your Energy ' 5...Level-2 Charger-Installation Mechanical 6...Level-2 Charger-Data,UL NEC,NEMA --------------------------------------------------------- Electric Vehicle Charger Additional Installation manuals,other hardware references and certifications available upon request Installation Permit Permit 2013 California Electrical code;Underwriters Laboratory(UL)listed charging 0.oc,rttor< of C V Ctrorcyrrr system.As Installation: Garago Not to Scats Typical of+two Gar 1.EV charging system information:Level 1 or 2/EV E system with UL listednumber or other approved nationally recognized testing laborain compliance with L2202,"Standard for Main Electric Vehicle(EV)Charging System Eq a Panel 2.Existing electrical service panel in at the residence.Include oadand circuit size to determine if electri pa el up r e is required.Provide I talc ti ns to determine if there is adequate car !sting panel.(CEC220)20 3.Panel upgrad>andtricI wiring shall be in confor wit the 2013 California Electrical Code. 4.Identlfy i a lectric meter is required stalled because of electricutility rate for EV char ' OSE SE locations(garage,carpo ,' r,exterior,etc.) Car Charger j RECll be installed in ac rda c h manufacturer's guideline and must be suitable for 11+i� V V, the environment(indoor/out the EV charging equipment is located in an area subject4,0 to physical(i.e.vehicular)Zdageand adequate barrier shall be installed.(i.e.3to 4"bollard) JUN Q 6 20'14 7.Submit installation ida�spart of submittal JAY X Slingshot Power, Contractor sl ingshot Equipment in this Electric Vehicle Charging System Title Sheet & Sheet Index Date:: 13-May-14 Project Details: Page Number: 164 Main St.,Los Altos,CA 94022 Equipment Type Manufacturers and Model Version: 1.0 Ph:650-308-9055 Scale: None Client: Martin Ku Fax:650-887-0345 1 Level-2 Charger Tesla Universal Mobile Project: 0 Address: 22126 Linda Vista Place California State Lic: B984488 COMMUNITY DEVELOPMENT DEPARTMENT Drawn: Paul Sherer City: Cupertino,CA 95014 BUILDING DIVISION-CUPERTINO APPROVED b �V This set of plans and specifications MUST be kept at the Job site during construction. It is unlawful to make any changes or alterations on same,or to deviate ' therefrom,without approval from the Building Official. ` �� ReFQ �t ~ The stamping of this plan and s e ' ' ions SHALL NOT aBy ��Qti be held to a an a of the violation provisions ce or State Law. DATE PERMIT (� Standard Method Residential Service Calulation 1.0 General Lighting:220.1 Total 2400 Sq Ft. 7200 VA 200_ Small Appliance:220.52(a) 200 3 Circuits x 1500 VA 4500 VA Laundry:220.52(b) Circuits x 1500 VA 1500 VA Applying Demand Factors:Table 220.42 1st 3000 VA x 100% 3000 VA Next 3000 VA x 35% 1050 VA 6 .y;J 7200 Remaining VA x 25% 1800 VA TOTAL.................................................................... 5850 VA 2.0 Fixed Appliances:220.53 "It shall be permissible to apply a demand factor of 75%for four appliances other than eletric ranges,clothes dryers,space heating equip,air-conditioning equip.) . YES/NO VA Dishwasher NO 0 VA Disposer NO 0 VA Microwave YES 1125 VA r � } Compactor YES 990 VA Pool/Spa NO 0 VA Attic Fan YES 1600 VA Other 0 0 VA TOTAL....................................... ........I 2786.25 VA , YES/NO VA 3.0 Eletric Dryer:(5000VA)220.55,Table 220.54 5000 VA x 100% =YES 5000 VA + 4.0 Cooking Equipment:Table 220.54 Oven 7200 VA x100% EYES 7200 VA Range 11000 VA x 100°x6 S 8000 VA Col C kW Other 0 VA t,t L, TOTAL.............................................. 15200 8.0 ciao-—d 5.0 Heating or A/C:220.60(non-coicident loads) VA AC Load Center Heating unit 1500 VA x 100% NO 0 VA ELECTRICAL LOAD TOTAL 1-2 Pole 50 Amp A/C Unit 6000 VA x 100% YES 6000 VA Service Total VA= 40236.25 Circuit Breaker Heating Pump 1500 VA 100% NO I OVA VA/240= 167.651A ps (loads)............................Take Largest Load 60001 The Sum of the rated current for the solar 6.0 Largest Motor 220.14(c)=430.24&440.6 breaker and the main breaker cannot exceed 0 VA 0 VA x 25% 120'A of the bus bar's rating X 7.0 EV Charger Level 2(5400)VA YES 5400 VA (National Electric Code Section 690.64) Slingshot Power, Contractor , ,- Charain[System load Calculations & EV Charger Circuit Schematic Date: 13-May-14 Project Details: Page Number: 164 Main St.,Los Altos,CA 94022 Equipment Type Manufacturers and Model Version: 1.0 Ph:650-308-9055 Scale: None Client: Martin Ku Fax:650-887-0345 1 Level-2 Charger Tesla Universal Mobile Project: 0 Address: 22126 Linda Vista Place California State Lic: B984488 Drawn: Paul Sherer City: Cupertino,CA 95014 t 1 GENERAL NOTES(Cont) UNGROUNDED PANEL ❑ POSITIVE GROUNDED PANEL E]1.Local utility provider shall be notified prior to use and activation of any solar ABBREVIATIONS NEGATIVE GROUNDED PANEL photovoltaic installation. 2.No sheet metal or tech screws shall be used to ground disconnect enclosure A...........Ampere MICROINVERTERS ❑ with tin-plated aluminum lugs;proper grounding/ground bar kits should be AC........Alternating Current used. BLDG.. Building Structure CONC...Concrete. 3.All exterior conduit,fittings,and boxes shall be with rain tight and approved DC.........Direct Current THIS PROJECT SHALL COMPLY WITH: for use in wet locations.(NEC 314.15a). EGC.......Equipment Grounding Conductor THE- (E)..........Existing HE•(E)..........Existing 01 CA BUILDING CODE 4.Adequate spacing are maintained between any plumbing vents extending EMT.......Electrical Metal Tubing 01 01 CA PLUMBING VODE through the roof and the underside of the photovoltaic panels. GALV....GalvanizedC, 2 0 CA RESIDENTIAL CODE GEC.......Grounding Electrode Conductor © / 20 CA ENERGY CODE 5.Separation distance measurement from bottom of panel to top of roof GND.......Ground 2 10 ECHANICAL CODE covering shall be minimum 4". HDG.......Hot Dipped Galvanized 2, IOCAC.TTL-11(-'()IINTVFTRF.CC)DF. I..............Current California Cocle of Regulations 6.Grounding bushings are required around pre-punched concentric knockouts Imp.........Current At Maximum Power Title4Part 3 on the do side of the system.(NEC 250.97). Isc...........Short Circuit Current a kVA........Kilovolt Ampere California Building Siti)ndards Commission Kilowatt 7.Back-fed breaker must be at the opposite end of bus bar from the main kW.......... Based on2011' NOw;dj }ect1'ia� (�de,:, breaker or main lug supplying current from the utilities. LBW.......Load Bearing Wall MIN........Minimum 8.All conductors exposed to sunlight are listed as sunlight resistant. (N)•••••.••••Neutral P g g NEUT.....Neutral ),:illa . x n 9.No building,plumbing or mechanical to be covered by the solar array. - OC..........On Center NTS........Not To Scale p 10.Smoke alarm and carbon monoxide alarm required per CRC R314&R315. PL...........Property Line POI.........Point of Intersection 11.All work to comply with 2010 California Building Code;2010 Electrical PV..........Photo Voltaic SCH........Schedule EF FE.CT W Code[2008 NEC]-article 690,all manufacture's listing and installation JAtNIJARY 1,2014 instructions. SS...........Stainless Steel irfw #a nai':i.F;xJ�Mw t6 sw iiarytVe;aw�gxxy;sg STC........Standard Testing Conditions 12.Inspection required for roof connection mounting assemblies prior to TYP........Typical installing solar module. 2Pole......Grounding System(N)&GND UPS........Uninterruptible Power Supply 13.This system is GRID-INTERTIED VIA a UL Listed or OSHA Approved UFER......Grounding system to foundation Test LAB certification ID. V.............volt Vmp........Voltage at Maximum Power 14.This System has no batteries,No UPS. Voc.........Voltage at Open CircuitW............Watt 15.SOLAR Mounting Rails,SubRails,Poles are all to be grounded to earth. 3R...........NEMA 3R,Raintight All Work to be done to 2010 California Electrical Code(CEC)and shall also X comply with 2008 National Electric Code as amended by the 2013 CEC Slingshot Pow o or C "M Charging System General Notes lingsh<;A . Date: 13-May-14 Project Details: 164 Main St.,Los Altos,CA 94022 Equipment Type Manufacturers and Model Version: 1.0 c0c) Ph:650-308-9055 Scale: None Client: Martin Ku Revtewey co Fax:650-887-0345 1 Level-2 Charger Tesla Universal Mobile Project: 0 Address: 22126 Linda Vista Place California State Lic: 6984488 Drawn: Paul Sherer City: Cupertino,CA 95014 ELECTRICAL NOTES ELECTRICAL NOTES(Con LEGEND 1.No guardrails are required for installed solar energy devices pursuant to LAMC 91.1013.5 17.All ungrounded conductors of a multiwire branch circuit will be identified ny phase and system per 210.5E)Utility Meter& 2.All PV System components shall be listed by a recognized testing agency(i.e.:UL,OSHA test Labs etc) 18.Either UL Laboratories or an OSHA Test Laboratory certifying station shall be listed on all equipment in Warning Label compliancewith 110.3 3.Wiring material shall be suitable for sun exposure and wet location,field applied protective coatings are ` Inverter W/Integrated not acceptable. 19 Circuits over 250V to Ground shall comply with 250.97,250.92(B) DC DISCONNECT 4.AI1PV modules and associated equipment and wiring material shall be protected from any physical 20 DC Conductors either do not enter the BLDG or are run inmetalic raceways or enclosures to the first ` damage. accessible DC disconnecting switch means per 690.3(E) DC DISCONNECT& 5.In one and two family dwellings,live parts in PV source circuits amp output circuits over 150volts to 21.All wires shall be provided with proper strain relief and any anti abrasion systems at all entry into boxes as WARNING LABELS ground shall not be accessible to other than qualified persons while energized. required by UL or OSHA Listings AC DISCONNECT& 6.All Field installed junction,pull and outlet boxes located behind modules or panels shall be accessible 22.All Modular/or module frames shall be grounded to earth at the UL-or OSHA Listed Location provided by WARNING LABELS directly or by displacement of a module(s)or panel(s)secured by removable fasteners. the manufacturer using proper lsted grounding hardware. 7.signs shall be posted adjacent to each PV disconnect and inverter to indicate 23.Module frames/framework(s),rails and posts shall be bonded with equipment ground conductors and JUNCTION BOX grouunded at the main electric panel. "PHOTOVOLTAIC SYSTEM" C 24.The DC grounding electrode conductor shall be sized according to 250.166(B)and 690.47L DC COMBINER BOX& 8.All Wiring shall comply to CEC Table 310.16 for sizing WARNING LABELS 25.The installing Contractor will confirm that proper earth to ground installed in the building eith UFER or Eli 9.When a BACKFED BREAKER is the method of utility interconnection,Breaker shall not read line and Two pole systems. load. DISTRIBUTION PANEL 26.EACH MODULE SHALL BE GROUNDED USING UL LISTED CUTIN GROUNDING LAY-IN LUG &WARNING LABELS a 10.All conduit,fittings,boxes shall comply with NEMA NEC 314.15A LOCATED AT THE MANUFACTURER'S SPECIFIED LOCATION ON THE MODULE IN ` ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND IN ACCORDANCE CEC WITH A 11.There shall not be any hanging wires underneath any PV panels(CEC 110.12) CONTINUOUS BARE CU WIRE SUCH THAT REMOVAL OF A MODULE FOR SERVICE SHALL NOT LOAD CENTER& INTERRUPT GROUNDING OF REMAINING MODULES.ALL PANELS GROUNDED TO EACH tea- WARNING LABELS 12.Equipment Grounding conductor shall be#6 AWG unless not subject to damage(CEC250.120C) OTHER&FRAME BY A MINIMUM#6 BAE GROUND WIRE TO MAIN PANEL GROUND TO EARTH 13.Working Clearances around the existing electrical equipment and well as the new electrical equipment 27National Electric Code 690.64 Point of Connection The output of a utility-interactive inverter shall be DEDICATED PV will be maintained in accordance.(CEC 110.26) connected as specified in 690.64,Bus or Conductor Rating.The sum of the ampere ratings of over current SYSTEM METER devices in circuits supplying power to a bus bar or conductor shall not exceed 120 percent of the rating of the 14.There will be Labels to indicate PV-SOLAR AC Breakers in Main Panel bus bar or conductor.In systems with panel=boards connected in series,the rating of the first over current device directly connected to the output of a utility-interactive inverter(s)shall be used in the calculations for all r •E i�; CONDUIT RUN "DO NOT RELOCATE SOLAR BREAKERS IN THIS PANEL" bus bars and conductors. 15.A11 terminal connections shall be rated at Yeast 90 degrees C. X JaK4/:' A' 16.All terminals that are of the disconnecting means may be energized in the open position,a sign shall be Slingshot Power,Contractor slinyZDhat. Charging System Electrical Notes Date: 13-May-14 Project Details: ber: 164 Main St.,Los Altos,CA 94022 Equipment Type Manufacturers and ModelVersion: 1.0 i Ph:650-308-9055 Scale: None Client: Martin Ku � �na R 0 Fax:650-887-0345 1 Level-2 Charger Tesla Universal Mobile Project: 0 Address: 22126 Linda Vista Place E E(� California State Lic: B984488 Drawn: Paul Sherer City: Cupertino,CA 95014 �G �h� , CHARGING RATE OF 32 MILES RANGE PER HOUR AT MAX POWER mew di-ven NENT--k 14-30 30 10 TEC'.HNICAL SPE(--IFI(--.ATIONS gener3ton NENIA L14-30 30 10 UNIVERSAL C.ONNECTOR CHARGE TIMES o1S cirven NEIN-k 10-30 30 10 Breaker Charge Adapter Outlet Rating(Amps) Time(Hours) motel AC imits NETN°LA 6-20 20 14.5 NE?vLk 14-50 (Included) 50 6 AC uuts --- NENfA 6-15 15 19 34 electrical vmlders NF.NIA 6-50 50 6 standard 3-pravc-, 'e— higber CWrent NENIA 5-20 20 37 AC umir, communcial NEZVIA 6-30 equipmumt 30 .10 14E1VIA 5-15 stmxhxd 3 prmg 15 48 X Slingshot Power,Contractor -4—r............... Iingshot Charging System Level-2 Charger Datasheet Information Date: 13-May-14 Project Details: Page Number: 164 Main St.,Los Altos,CA 94022 Equipment Type Manufacturers and Model Version: 1.0 Ph:650-308-9055 Scale: None Client: Martin Ku Fax:650-887-0345 1 Level-2 Charger Tesla Universal Mobile Project: 0 Address: 22126 Linda Vista Place California State Lic: B984488 Drawn: Paul Sherer City: Cupertino,CA 95014 Q)� lei/