Loading...
R-2014-18b OFFICE OF COMMUNITY DEVELOPMENT CITY HALL 10300 TORRE AVENUE•CUPERTINO, CA 95014-3255 C U P E RT 1 N O (408)777-3308• FAX(408)777-3333•planninq(a�cupertino.org July 10, 2014 WHY Construction Attn: Hsin-Fu Lin 6805 Westmoor Wy San Jose, Ca. 95129 SUBJECT: TWO STORY PERMIT ACTION LETTER-Application R-2014-18: This letter confirms the decision of the Director of Community Development, given on July 8, 2014, approving a Two Story Permit to allow the construction of a 2,692 square foot single family residence, located at 18832 Tuggle Avenue, with the following conditions: 1. APPROVED PROTECT This approval is based on a plan set entitled, "Mrs. Yang Residence Rebuild, 18832 Tuggle Ave., Cupertino CA 95014-3626" consisting of nine sheets labeled "A1.1 to A3.3, C.0 and CALG", dated Received June 16,2014, except as may be amended by conditions in this resolution. 2. ANNOTATION OF THE CONDITIONS OF APPROVAL The conditions of approval set forth shall be incorporated into and annotated on the building plans. 3. ACCURACY OF THE PROTECT PLANS The applicant/property owner is responsible to verify all pertinent property data including but not limited to property boundary locations, building setbacks, property size, building square footage, any relevant easements and/or construction records. Any misrepresentation of any property data may invalidate this approval and may require additional review. 4. CONSTRUCTION PLAN SET REVISIONS/CLARIFICATIONS Prior to issuance of building permits, the construction plan submittal shall include the following information: a. The privacy planting plan shall be revised to show the exact details of the plantings proposed within the vision cones.This includes number, spacing, and planting size. 5. CONSULTATION WITH OTHER DEPARTMENTS The applicant is responsible to consult with other departments and/or agencies with regard to the proposed project for additional conditions and requirements. Any misrepresentation of any submitted data may invalidate an approval by the Community Development Department. 6. COMPLIANCE WITH PUBLIC WORKS CONFIRMATION FORM The project shall comply with the requirements indicated on the Public Works Confirmation form, including, but not limited to, dedications, easements, off-site improvements, undergrounding of Two Story Permit Action Letter Page 2 R-2014-18 utilities, all necessary agreements, and utility installations/relocations as deemed necessary by the Director of Public Works and required for public health and safety. The Public Works Confirmation is a preliminary review, and is not an exhaustive review of the subject development. Additional requirements may be established and implemented during the construction permitting process. The project construction plans shall address these requirements with the construction permit submittal, and all required improvements shall be completed to the satisfaction of the Director of Public Works prior to final occupancy. 7. PRIVACY PROTECTION COVENANT The property owner shall record a covenant on this property to inform future property owners of the privacy protection measures and tree protection requirements consistent with the R-1 Ordinance, for all windows with views into neighboring yards and a sill height that is 5 feet or less from the second story finished floor. The precise language will be subject to approval by the Director of Community Development. Proof of recordation must be submitted to the Community Development Department prior to final occupancy of the residence. 8. EXTERIOR BUILDING MATERIALS/TREATMENTS Final building exterior treatment plan (including but not limited to details on exterior color, material, architectural treatments and/or embellishments) shall be reviewed and approved by the Director of Community Development prior to issuance of building permits. The final building exterior plan shall closely resemble the details shown on the original approved plans. Any exterior changes determined to be substantial by the Director of Community Development shall require a minor modification approval with neighborhood input. 9. LANDSCAPE PROJECT SUBMITTAL: Prior to issuance of building permits, the applicant shall submit a full landscape project submittal per sections 14.15.040 A, B, C, and D of the Landscaping Ordinance if more than 2,500 square feet of landscaping area is proposed. The Water-Efficient Design Checklist (Appendix A of Chapter 14.15), Landscape and Irrigation Design Plans, and Water Budget Calculations shall be reviewed and approved to the satisfaction of the Director of Community Development prior to issuance of building permits. 10. INDEMNIFICATION To the extent permitted by law, the Applicant shall indemnify and hold harmless the City, its City Council, its officers, employees and agents (the "indemnified parties") from and against any claim, action, or proceeding brought by a third party against the indemnified parties and the applicant to attack, set aside, or void this ordinance or any permit or approval authorized hereby for the project, including (without limitation) reimbursing the City its actual attorneys' fees and costs incurred in defense of the litigation. The City may, in its sole discretion, elect to defend any such action with attorneys of its choice. 11. NOTICE OF FEES, DEDICATIONS, RESERVATIONS OR OTHER EXACTIONS The Conditions of Project Approval set forth herein may include certain fees, dedication requirements, reservation requirements, and other exactions. Pursuant to Government Code Section 66020(d) (1), these Conditions constitute written notice of a statement of the amount of such fees, and a description of the dedications, reservations, and other exactions. You are hereby further notified that the 90-day approval period in which you may protest these fees, dedications, reservations, and Two Story Permit Action Letter Page 3 R-2014-18 other exactions, pursuant to Government Code Section 66020(a), has begun. If you fail to file a protest within this 90-day period complying with all of the requirements of Section 66020, you will be legally barred from later challenging such exactions. Please note that if this permit is not vested within a year, it shall expire on July 8, 2015. Staff has made all the findings that are required for approval a Two Story Permit as required by the of Cupertino's Municipal Code, Chapter 19.28.140 (A). Also, please note that an appeal of this decision can be made within 14 calendar days from the date of this letter. If this happens, you will be notified of a public hear' g,which will be scheduled before the Planning Commission. Sincerely, ; Gian Mar ' e Assistant Planner 408-777-3319 gianm@cupertino.org Enclosures: Approved Plan Set CC:Lisa Yang,18832 Tuggle Ave,Cupertino Ca 95014 t GENERAL R �TES 1. IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND SUBCONTRACTORS TO CHECK AND VERIFY ALL DIMENSIONS AND CONDITlONS INDICATED ON THESE DRAWINGS AND MAKE KNOWN ANY DISCREPANCIES PRIOR TO COMMENCING 1HEIR WORK. 2. THESE DRAWINGS ARE INTENDED FOR USE IN A NEGOTIATED CONSTRUCTION CONTRACT AND,1}iEREFORE,MAY NOT SPECIFlCA�LY DETAILS OR SPECIFY MATERIALS AND/OR MANUFACTURERS. 3. THE CONTRACTOR SHALL PROVIDE ALL SAMPLES AND/OR CUT-SHEETS AS REOUIRED TO ASSIST OWNER OR HIS AGENT IN MAKING MATERIAL SELECTIONS. 4. FOR THE PURPOSE OF ESIIMATING,THE CONTRACTOR SHALL USE TNE MATERIALS SELECTED BY THE OWNER,OR IN ABSENCE OF SAME, HE SHALL PROVIDE AN ALLOWANCE AMOUNT AND SO CONDITION ANY COST ESTIMATE. 5. ALL MATERIALS SPECIFIED IN THESE DRAWINGS SHALL BE INCLUDED IN SUCH ESTIMATE. 6. NO GUARANTEE OF QUALITY OF CONSTRUCTION IS IMPLIED OR INTENDED BY THE CONSTRUCTION DOCUMENTS.AND THE CONTRACTOR SHALL ASSUME FULL RESPONSIBIUTY FOR ANY OR ALL CONSTRUCTION DEFICIENCIES. 7. THE GENERAL CONTRACTOR SHALL HOLD HARMLESS,INDEMNIFY AND DEFEND THE DESIGNER FROM ANY ACTION INITIATED BY THE INI11A�OWNER OR ANY SUBSEQUENT OWNERS FOR CONSTRUCTION DEFlCIENCIES,MODIFICAT10N5 OR SUCH CONDIT10N5 WHICH MAY BE BEYOND THE CONTRO�OF THE ARCHITECT. 8. ALL WORK SHALL COMPLY WITH APPLICABLE CODES AND TRADE STANDARDS WHICH GOVERN EACH PHASE OF WORK,INCLUDING BUT NOT LIMITED TO CALIFORNIA BUILDING CODE(CBC),CALJFORNIA MECHANICAL CODE(CMC), NA110NAL ELECTRICAL CODE(NEC),CAIJFORNIA PLUM8ING CODE(CPC),AND ALL APPLICABLE LOCAL CODES AND LEGISlAT10N. 9. THE CONTRACTOR SHALL REVIEW AND RECORD THE CONDI110NS OF ALL EXISTING SITE IMPROVEMENTS INCLUDING PAVED AREAS,HE SHALL MAKE KNOWN ALL EXISTING DAMAGED OR DISREPAIRED ITEMS AND CONDIPONS THAT MAY WORSEN DUE TO THE CONSTRUC110N. 10. ALL ITEMS IN GOOD CONDITION SHALL BE MAINTAIN IN 711EIR PRESENT CONDITION AND ANY REPAIR OR DAMAGE WHICH OCCURS DURING CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. 11. CONTRACTOR SHALL THOROUGHLY EXAMINE THE SITE AND SATISFY HIMSELF AS OF THE CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED. 12. THE CONTRACTOR SHALL VERIFY AT THE SITE ALL MEASUREMENTS AFFECTING HIS WORK AND SHALL BE RESPONSIBLE FOR THE CORRECTNESS OF SAME. 13. NO EX1RA COMPENSA�ION WILL BE ALLOWED TO THE CONIRACTOR FOR THE EXPENSES DUE TO HIS NEGLECT TO EXAMINE OR FAILURE TO DISCOVER CONDITIONS WHICH MAY AFFECT HIS WORK. 14. ALL NEW INTERIOR PAINT COLOR,FLOOR,WALLS AND CEILING FlNISHES SHALL BE SELECTED BY OWNER AT THE i1ME NMEN IT IS NECESSARY FOR THE COMPLETION OF 1HE PROJECT. 15. ALL PUBLIC IMPROVEMENTS SHALL BE MADE IN ACCORDANCE WITH 11-IE LATEST ADOPTED CITY STANDARDS. 16. THE STORING OF GOODS AND MATERIALS ON SIDEWALK AND/OR STREET WALL NOT BE ALLOWED UNLE55 THE CONTRACTOR HAS APPLIED AND SECURED A SPECIAL PERMIT WHICH ALLOWS SUCH STORAGE TO BE PLACED. 17. SPECIAL INSPEC110NS ARE REQUIRED FOR THE INSTALLATION OF EXPDXY ANCHORS AND HOLDOWNS.SUBMIT A COMPLETED CITY OF CUPERTINO SPECIAL INSPECTION AND TESTING SCHEDULE.TO OBTAIN FORM TO GO THE BUILDING DEPARTMENT WEBSITE(WWW.CUPERTINO.ORG)UNDER FORMS AND GUIDES. 18. PROVIDE(2)WET STAMPED AND SIGNED COPIES OF A REVIEW LETIER FROM THE GEOTECHNICAL/CIVIL ENGINEER FOR THE FOUNDATION PLAN AND DETAILS TO SHOW n-IAT HE/SHE HAS REVIEWED THEM AND TAHT THE OVERALL PROJECT DESIGN IS IN GENERAL CONFORMITY WITH THE GEOTECHNICAL SOILS ENGINEERING RECOMMENDAT10N5 FOR THE PROPOSED CONSTRUC110N. SCOPE OF WORK 1. NEW 1ST FLOOR INCLUDES: (N)PORCH,(N)LIVING RM.,(N)POWDER RM., (N)LOBBY,(N)BAT}i #1, (N)BEDROOM#1,(N)LAU. (N)FAMILY RM.,(N)KITCHEN AND(N)DINING RM. NEW 2ND FLOOR INCLUDES: (N)BEDROOM#2,(N)BEDROOM #3,(N)M.BEDROOM, (N)M.BATH,(N)BATH#2 AND(N)LOUNGE. THE TOTAL iST FLOOR IS 1,330 S.F. 2ND FLOOR IS 925 S.F. GARAGE IS 437 S.F. 2. ALL NEW WINDOWS ARE DOUBLE PANEL. 3. INSTALL NEW ROOF,ROOFlNG TO BE LT.WT.CONC.T1LE ROOF. 4. NEW EXTERIOR STUCCO FINISHED. 5. RELATED ELECTRICAL,MECHANICAL AND PLUMBING WORK. 6. (N)ELECTRICAL PANEL TO BE 200 AMP. 7. (N)GAS MTER. SYMBOLS � /� }-COLUMN GRID LINE N0. �� NO SECTION N0. A.X F SECTION SHEET N0. ELEVATION N0. NO A.X ELEVATION SHEET N0. NO DETAIL N0. A.X DETAIL SHEET N0. , REVISION N0. OEXISTING DOOR NO DOOR N0. q � DOOR SCHEDULE DOOR TYPE NO INTERIOR ELEVATIONS A.X INDICATOR RM.�E ROOM NAME FL. �F FLOOR FlNISH B LDG D. 'A SITE AREA: 0137 ACRES 5,985 S0. FT. EXISTING BUILDING FLOOR AREA(ALL DEMOLISHED) FLOOR AREA: 1ST FL 0 SQ. FT. 2ND FL 0 SQ. FT. GARAGE 0 S0.FT. TOTAL EXISTING FLOOR: 0 S0. FT. PROPOSED ADDITION FLOOR AREA LIVING AREA: 1ST FL 1,330 SQ.FT. 2ND FL 925 50. FT. PORCH UNCOUNTED 49 S0.FT. GARAGE 437 SQ. FT. TOTAL PROPOSED FLOOR 2,692 S0. FT. MAX. ALLOWED FLOOR AREA 5,985 X 459,= 2.693.25 S0. FT. TOTAL FLOOR AREA � 1,330+925+ 437= z.692 S0. FT. F.A.R.: 2,692/5,985= 44.98 %<457 i � LANDSCAPE ARE : 4.»2 �50. FT. LANDSCAPE COVERAGE 60.00 � APN: 375-32-028 ZONE: R1-5 Qi OCCUPANCY: R-3/U CONSTRUCTION TYPE: V-B STORY(IES): 2 AUTO.FIRE SPRINKLER: YES DESIGN COMPLY WITH: 2013 CBC Ed. 2013 CRC Ed. 2013 CFC Ed. 2013 CMC Ed. 2013 CPC Ed. 2013 CAIIFORNIA ELECTRIACL CODE Ed. 2010 CALIFORNIA ENERGY CODE Ed. 2013 CALJFORNIA GREEN BUILDING CODE Ed. VICINITY MAP ei arc m,,. * . a.,. � i, .t ?, m �.:, .E'�,��' �'o t,w i��,� _ � ,...��,� � z � k . . _ �� a"'N..� , F � s � ~ �+� ` _ '�j� rfrp4, _ i..wnw�+,» � . .��r m S� � - ... ,nea,a�3c� s.�_ ;� �' ��� .F i� � ... .�C✓+A�e ���k:Aee S��eIiCZ �� � .,, � M � wa,. f� 8�,����.r � ��j � � r � �:���� � ;� �= ��r��« - � .- � y��EYI� ' `tlOi i �LOC� N ` , � � ,..o� .-,, �� ��w.P���:� �p�ro��*�te �b��, �. `�;, r`� � �,,� � ��, � = �� � �ntingn pB�C����u��� � - _ a � . � -� �� e Mar���`:�.'� ��:� `;�°;°�°� � . r�; s � � � � _ � �� .:'.�J. < �Y - .. C ,�en�,ai Cn Y �:.. '��^c� ffic�.r�-.,�m.�,.am.a.,.m.m.�. SHEET INDEX A7.1 TITLE SHEET & SITE PLAN �•� LOT COVERAGE & PRIVACY LANTINC �•� PROPOSED 1 ST FLOOR PLAN �•2 PROPOSED 2ND FLOOR PLAN A3.1 (N) ELEVATIONS A3.2 (N) ELEVATIONS A3.3 ROOF REF. & SECTION C.0 BOUNDARY SURVEY CALG CALGREEN RESIDENTIAL CHECKLIST/,� N RES IDENCE REBUILD MRS . YA G 18832 TUGGLE AVE., CUPERTINO, CA 95014-3626 � (N)15 GALLON (N) 15 GALLON (N)15�ALLON �' ITALIAN CYPRESS ITALIAN CYPRESS ITALIAN CYPRESS is-o' �-s° �s'-s �-3- �s'-o• s'-o� 6'HT. 6'H�-o• 6'HT. 5'-a' 5�.0� o,. s�.00� °,- .I �f � 0 ,� r .n 0 15'-0' I � L._ z %"°i �J N O � � _ _/ _ _ _ _ - ..� IM�'a'MS'o' vw�c/s.c. A 2. �o rtw.tti. o. 1 � i . ���� qQ�a . ��LL , Iw1ro•.ro• r------1 .. � sudw�/�c .. irrv. �� �I (N1 N.HOVU�y � �I. j I I O ` J I b\�j n� --- -- � " -, xs.o ��� \/ Ilii..L.�'J.L� I T e N�.. /\ '°"° I r--_, �o�, o _� ��� _�� � ---J ' (N1 LIXINCE I �°.° L- � �-� n�c kX Ibr� ._. '. �"sni+'c° I\/I Y-a ��� Ccxr.ss L x J �-----� � � �(Nl BEDROOIA/2� � � Hoxo � I �w� I I � N)2o'xso' L-----J . p 3/Fq�MG�G � I I (N'��� � EOIESS �" ... � -..: � 5'-t�' I 3'-.:.' I?'-11'� t3.5• 57.00' (N)15 C�ALLO� ITALIAN hYPR 6'H T. .^ (N) 15 LLOP ITALJAN YPRE 6'H T. .i � i (N) 15 GA'ON ITALIAN CY ESS 6'H T. i G o 'i o (N) 15 GAL ON rv ITALJAN C ESS 6'H T. � 'I .� � m � � IS'-0' �i - � (E)PINE TREE � I TO REMAIN � PROPOSED LANDSCAPE A� REA��0 � 5,985-392-496-1,330-437=3,330 S.F. (N)15 GALL01 LANDSCAPE3,330 SF ITALIA CYPRf Z 6'H T. � 20'-0"REAR � �SETBACK LINE �..... .... .. . ... _ _. .... w N 1 Q '�(E)PEACH TREE } TO REMAIN o HARDSCAPE DIA.0'-6° '; in AREA - 0 496 S.F. �l ' 9 SF \ ��. (N)8'0"ic6'B' ,ao� YIdNG DR ,...,._.„ �I i00�.�.... y•I G'w. _ � �� - r �r�� .�7 �I� ,� (N1 OINNG RY. HMO Q z 1,330 SF c�o. � �� (Nl LNNG R11- II NDMD I ��� � �o. a� �_ ��. ,xa���� ,q a sudrwh.n �c+�c.aQ � % N E�w.a QEqS55 i (Nl FNYII Y RII. � Hltll.tl� (Nl LAII. _n�- ■__'� ■�� �,. � J�0 � � c�so=se (N)15 GALLON a�� ITALIAN CIPRES 6'H T. (N)BmROdI It � w+o . w��.. - Z � J O Ml B�TM I1 Y O U h n m r � k y %,, w . //� x w � L nc.� ,r1, 1v/ `�-a �°� o��. I� � N � I � �/ � (N)15 ALLON ITALIAN CYPRE5S 6'HT. � x I . �20 0^:F�?ONT MA DRIVEW Y BE N NSTRUC D OF MO � AESTHETICA Y PLEA', SET5ACK LJNF �RIALS UCH AS � STAMPED C NCREIE, ' PAVERS.0 PATTERP ` ` Q CONCRETE. � o � 5'-0' "-0 '-0 6'-11" '-0 '-6 6'-2' ' 1�•6�10'." g'-p" r �•-r �._�. i'-s` CON . MPERVIOUS°AREA �._6. Qj -'3J?SnF. �. 392,1,140=34.39%<509�` (N)COAST LIVE OAK TREE C ��,��pERVI US 392 F 24"BOX OR LARGER WITH A , u a MIN. HEIGHT OF 6 FEET. � s�.00� SITE PLAN �NOlE: CONSTRUCT SIDEWALKS,WALKWAYS Q AND/OR PA1105 WITH PERMEABLE SCnLE:i/8'=t'-o' � SURFACES. �; •NOTE: PRIOR TO ISSUANCE OF BUILDING �� PERMIT, T}iE LANDSCAPE WATER-EFFICIENCY CHECKUST IN APPENDIX A OF CHAPlER 14.15 02 WILL NEED TO BE FILLED OUT AND A FULL LANDSCAPE PROJECT SUBMITTAL PER SECTION 14.15.040 WILL BE REQUIRED.IT IS PREFERRED THAT THIS INFORMATION BE PROVIDED AT 1}iE T1ME OF THE PLANNING ENTITLEMENT. � � � t NOTE: USE ONE OR MORE OF DESIGN MEASURES BELOW, 1 ,330 S F A. DIRECT ROOF RUNOFF ONTO ,�r� VEGETATED AREAS. B. DIRECT ROOF RUNOFF INTO t�j ��5 S F CISTERNS OR RAIN BARRELS FOR R EU SE. C.DIRECT RUNOFF FROM SIDEWALKS, � WALKWAYS, AND/OR PAT10S ONTO � VEGETATED AREAS. D.DIRECT RUNOFF FROM DRIVEWAYS AND/OR UNCOVERED PARKING LOTS ONTO VEGETATED AREAS. � E. CONSTRUCT SIDEWALKS, WALKWAYS GA�G E � AND/OR PAT10S WITH PERMEABLE SURFACES. ��� �� � WHY Constuction DESIGNER I Jack Lin CSLB #964820 6805 Westmoor Way San Jose,CA 95129 TEL: (408) 218-0587 Email: fu333�yahoo.com _ . / � ui w�.a�sg�.a�,m�m���dm� dicW�d rapnsenleE by 1M1�a tra�ing .�.d ny a�e a.wov..+r d �e�caeTaonw� a e e.a c.d.e«me x.NOp.e ta�u on a�a-n m t� �tc m.v.cr�.e�'a�,r`v^ w � n aaa,Geigna 9 t v�°'s nanb.�..dnco.a�i..a� y P...m.�o av����,ro,a�Y p.urpwe noea«.er ��no�t ine ttM o�,�,�s:a,oi M�Y CU'fRUCINII IJI'nformat'on�to De re�lfiad by all pR.«,.�omca��a,e u�oMi �<��ai�.�u,ce.ii�inr a�u. S�ould any error.mllict a ncnseten�cy avvro�m Ne bawings.�nia or«m�t ee�oinka mr haw�uo�e oror co P,oc«ai�a.+m my moaaucuon. OWNER: MRS. LISA YANG lEL: 408-393-3951 EMAIL: I isa yan g777�g m ail.com MR. CANFA CHEN 1EL: 408-726-2956 EMAIL: ccfa1234�yahoo.com � � Z � W W � Q � M � � W W � � � � Q V � � � Z � Z Q N � M W � 00 a � ' . r V � � � � TITLE SHEET � SITE PLAN �arE: 03/15/14 �oe No. WHY14-0321 ISSUE&REVISION 04/02/14 LANNING REVIEW SHEET N0. A1 .1 DRAWN BY: JL DEMOLITION NOTES 1 THE GENERAL CONTRACTOR SHALL FURNISH ALL LABOR �ATERIALS AS REOUIRED TO COMPLETE DEMOLITION AND REMOVAL OF ALL ITEMS INDICATED ON RC USA DRAWINGS OR AS OTHERwISE DIRECTED BY THE OwNER 2. THE CONTRACTOR TO VIEW AND VERIFY ACTUAL CONDITIONS AT ALL LOCATtONS WHERE ALTERATIONS TO THE EXISTING BUILDING OCCUR. WHEN WALLS, PARTITIONS, AND OTHER WORK EXISTS WHERE NEW WORK IS INDICATED, ALL SUCH EXISTING WORK SHALL BE REMOVED. VERIFY ALL SUCH CONDITIONS AT THE SITE. 3. THE CONTRACTOR SHALL REPORT TO ARCHITECT AfJY AND ALL CCNDITIONS WFiICH MAY INTERFERE WITH OR OTHERWISE AFFECT OR PREVENT THE PROPER EXECUTION AND COMPLETION OF THE WORK OF TH�S CONTRACT. 4. THE GENERAL CONTRACTOR SHALL EXECUTE ALL WORK WITHIN THE REGULATIONS OF THE BUILDING FOR DEMOLITION AND REMOVAL OF DEBRIS. INCLUDING OVERTIME WORK REQUIRED. 5. THE GENERAL CONTRACTOR SHALL AT ALL TIMES PROTECT THE PROPERTY OF THE BUILDING LANDLORD INCLUDING, BUT NOT LIMITED TO FLOOR COVERING,CEILING GRID AND TILE, LIGHT FIXTURES, DOORS, WINDOWS, FRAMES,HARDWARE, CABINETRY, PLUMBING FIXTURES, ELECTRICAL AND AIR CONDITIONING EOUIPMENT,PERIPHERAL ENCLOSURES, ETC. 6. THE GENERAL CONTRACTOR SHA�L ERECT ALL NECESSARY PLASTIC DROP CLOTH BARRIERS TO PROTECT ADJACENT BUILDING PROPERTY WHILE DEMOLITION AND CONSTRUCTION ARE IN PROGRESS. 7. THE GENERAL CONTRACTOR SHALL SURVEY ALL EXISTING FINISHED SURFACES TO INCLUDE CORNER BEADS. STOPS, ETC. FOR CHIPS, CRACKS, HOLES, DAMAGED SURFACES, AND ANY OTHER DEFECTS CAUSING AN APPEARANCE DIFFERENT FROM A NEW,FINISHED, INSTALLATION. THESE DEFECTiVE SURFACES SHALL BE REPAIRED OR,IF BEYOND REPAIR, THE GENERAL CONTRACTOR SHALL REMOVE ALL EXISTING AND INSTALL NEW SURFACES TO THE SATISFACTION OF TSCGI AND THE OWNER 8. THE GENERAL CONTRACTOR SHALL INSPECT ALL EXISTING SURFACES AND WHERE AS A RESULT OF DEMOLITION, FINISHED SURFACES DO NOT ALIGN, THE EXISTING SURFACE SHALL BE CUT AND PATCHED. 9. ALL DAMAGED EXISTING AREAS TO REMAIN AND EXISTING AREAS AFFECTED BY DEMOLIl10N OR NEW CONSTRUCTION WORK SHOWN ON DRAWINGS SHALL BE PATCHED AS REQUIRED TO MATCH IMMEDIATE EXISTING ADJACENT AREAS IN MATERIAL, FIRE-RATING, FINISH, AND COLOR, UNLESS OTHERWISE NOTED. 10. ALL WORK DEMOLISHED SHALL BE REMOVED FROM THE PREMISES EXCEPT ITEMS TO BE REUSED OR RETURNED TO THE OWNER OR AS OTHERWISE DIRECTED. 11. IN ALL AREAS WHERE DEMOLITION(REMOVAL OF TILE, PARTIT10N5, ETC. CAUSES AN UNEVENNESS IN THE SLAB. THE CONTRACTOR SHALL PATCH TO LEVEL THE SLAB TO RECEIVE NEW FINISH FLOORING. 12. ALL EXPOSED LIGHT FIXTURES, WIRING, SWITCHES, CONDUIT, AND METAL MOLDING NOT BEING REUSED SHALL BE REMOVED AND EITHER STORED OR DISPOSED OF BY THE GENERAL CONTRACTOR AS INSTRUCTED BY THE OWNER. 13. THE GENERAL CONTRACTOR SHALL FURNISH A SYSTEM OF TEMPORARY UGHTS THROUGHOUT THE SPACE UNDER DEMOLITION AS REQUIRED. 14 THE GENERAL CONTRACTOR SHALL CAP OFF BEHIND FINISHED SURFACES ALL PROJECT PLUMBING, FLOOR ELECTRICAL/TELEPHONE OUTLETS, AND ALL OTHER PROJECTING ITEMS THAT ARE BEING ABANDONED. 15. THE GENERAL CONTRACTOR SHALL REMOVE ALL WALL CONDUITS LEFT AFTER WALL DEMOLITION INCLUDING SWITCH BOXES, PLATES, BRIDGES, OR ANY OTHER TELEPHONE OR ELECiRICAL WIRING OR EQUIPMENT. VERIFY WITH TENANT REUSE OF EXISTING CABLING PRIOR TO REMOVAL. 16. ALL"EXISTING TO REMAIN", °EXISTING", "RELOCATED", OR "NEW" ITEMS INSTALLED BY THE GENERAL CONTRACTOR,IN ADDITION TO BEING AMPLY PROTECTED THROUGHOUT THE PERIOD OF CONSTRUCTION, SHALL BE THOROUGHLY CLEANED TO THE SATISFACTION OF TSCGI PRIOR TO BEING TURNED OvER TO THE OwNER. 17. REFER TO ENGINEERING DRAWINGS FOR REMOVAL AND/OR RELOCATION IF REQUIRED OF HAVOC DUCTS, DIFFUSERS, SPRINKLER HEADS,EXIT LIGHTS, ETC 18. SOME DOORS AND FRAMES TO BE REMOVED SHALL 8E RETURNED TO OWNER. HANDLE CAREFULLY AND STORE ON SITE. GENERAL DEMOLITION NOTES 1 THE GENERAL CONTRACTOR AND ALL SUB-CONTRACTORS SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS OF THE PROJECT AND THE CONTRACT DOCUMENTS IN ORDER THAT DEMOLITION WORK WILL INCLUDE DEMOLISH�NG ALL ITEMS INCIDENTALS, WHETHER CALLED FOR OR NOT. 2. THE GENERAL CONTRACTOR SHALL REVIEW THE DRAWINGS AND SPECIFtCATIONS TO COORDINATED WITH EXISTING BUILDING CONDITIONS. ANY VARIANCE OR DISCREPANCY THAT ARISE FROM ABOVE REVIEW SHALL BE REPORTED TO THE ARCHITECT IMMEDIATELY FOR RESOLUTION. 3. CONDUIT DEMOLITION TO MINIMIZE INTERFERENCE WITH ADJACENT STRUCTURES. 4. PROVIDE, ERECT, AND MAINTAIN TEMPORARY BARRIERS AND SECURITY DEVICES. 5. ANY STRUCTURAL SUPPORT,BRACING AND SHORING NEED TO HAVE ENGINEER REVIEW PRIOR TO COMMENCE THE WORK. 6. LOCATE EXISTING UNDERGROUND UTILIIIES IN AREA TO AVOID DAMAGE BY DEMOLITION. 7. ALL DEMOLITION WORK TO BE PERFORM CAREFULLY, ITEMS TO BE REMOVED NEED TO REMOVE, DUMP AT LEGAL DUMP SITE, CLEAN THE WORK AREA AND PREPARE THE AREA TO RECEIVE NEW WORK AS SPECIFIED ON THE DRAWINGS 8. BACKFILL AREAS EXCAVATED AND OPEN PITS AND HOLES CAUSED BY A RESULT OF DEMOLITION. 9. ROUGH GRADE AND COMPACT AREAS AFFECTED BY DEMOLITION TO MAINTAIN SITE GRADES AND CONTOURS. 10. UNLE55 WHERE NOTED OTHERWISE, IMMEDIATELY REMOVE DEMOLISHED MATERIAL FROM SITE. LEAVE SITE IN CLEAN CONDITION. 11 DO NOT BURN OR BURY MATERIALS ON SITE 12. REMOVE AND PROMPTLY DISPOSE OF CONTAMINATED, VERMIN INFESTED,OR DANGEROUS MATERIALS ENCOUNTERED REPORT TO ARCHITECT AND RELATED AGENCIES AS REQUIRED. 13. CONDUIT OPERATIONS WITH MINIMUM INTERFERENCE TO USE AND THOROUGH PUBLIC WAY. MAINTAIN PROTECTED EGRESS AND ACCESS AT ALL TIMES. 14. DO NOT CLOSE OR OBSTRUCT ROADWAYS OR SIDEWALKS WITHOUT PERMITS. 15. ANY PIPE, CONDUIT, OR CABLE ORIGINALLY CONNECTED TO THE REMOVED ITEMS TO BE DISCONNECTED AND CAPPED PROPERLY IF THE ITEMS IS PART OF A SYSTEM THEN NEED TO RE-CONNECT TO EXISTING SYSTEM AND KEEP IN A WORKING CONDITION. 16. THE LOCATION OF DISCONNECTED AND/OR CAPPED LINES SHALL IDENTIFIED PUBLIC WORKS NOTES 1. ONSITE DRAINAGE(WITH ARROW AND SLOPE PERC� NO CONCENTRATED FLOW ACROSS THE RIGHT-OF-WAY. ._ �RAINAGE ONTO NEIGHBORING PROPERTIES. ALL DRAINAGE TO LANDSCAPE SEE ADDITIONAL COMMENTS#6. 2. CLEARLY SHOW ALL UTILITIES FROM THE HOUSE/PROJECT SITE TO THE STREET(ELECTRIC, ELECTRIC PANEL, GAS, WATER, SEWER), INDICATE AS NEW(N)OR EXISTING(E). 3. APPROVAL OF THESE PLANS DOES NOT RELEASE HE OWNER AND/OR CONTRACTOR OF THE RESPONSIBILITY FOR THE CORRECTIONS OF MISTAKES, ERRORS, OR OMISSIONS CONTAINED THEREIN. IF DURING THE COURSE OF CONSTUCTION IMPROVEMENTS, PUBLIC INTEREST REOUIRES A MODIFICATION OF/OR A DEPARTURE FROM THE CITY OF CUPERTINO SPECIFICATION OR THESE IMPROVEMENT PLANS, THE CITY ENGINEER SHALL HAVE THE AUTHORITY TO REOUIRE SUCH MODIFICATION OR DEPARTURE AND TO SPECIFY THE MANNER IN WF11CH THE SAME IS TO BE COMPLETED, AT THE SOLE EXPENSE OF THE OWNER AND/OR CONTRACTOR 4 CONTACT PUBLIC WORKS. (408) 777-3104, FOR INSPECTION OF GRADING, STORM DRAINAGE, AND PUBUC IMPROVEMENTS. 5. A�L PUBLIC IMPROVEMENTS MUST BE COMPLETED PRIOR TO OCCUPANCY. 6. CONTRACTOR IS RESPONSIBILE FOR DUST CONTROL AND ENSURING THE AREA ADJACENT TO THE WORK IS LEFT IN A CLEAN CONDICTION. 7 CONTRACTOR SHALL REVIEW CITY DETAIL 6-4 ON TREE PROTECTION PRIOR TO ACCOMPLISHING ANY WORK OR REMOVING ANY TREES. 8 UTILIZE BEST MANAGEMENT PRACTICES (BMP'S), AS REQUIRED BY THE STATE WATER RESOURCES CON7ROL BOARD,FOR ANY ACTIVITY, WHICH DISTURBS THE SOIL 9. A WORK SCHEDULE OF GRADING AND EROSION&SEDIMENT CONTROL PLAN SHALL BE PROVIDED TO THE CITY ENGINEER BY AUGUST 15. NO HILLSIDE GRADING SHALL BE PERFORMED BETWEEN OCTOBER t TO APRIL 15. 10. ALL NEW ELECTRICAL SERVICE(POWER, PHONE, AND/OR CABLE) SHALL BE UNDERGROUNDED. 11 TO INITIATE RELEASE OF BONDS, CONTACT THE PUBLIC WORKS INSPECTOR FOR FINAL INSPECTION. 12. AL�DOWNSPOUTS TO BE RELEASED TO THE GROUND SURFACE, DIRECTED AWAY FROM BUILDING FOUNDATIONS AND DIRECTED TO LANDSCAPED AREAS. 13. PRIOR TO BEGINING ANY WORK WITHIN THE PUBLIC RIGHT OF WAY, THE CONTRACTOR WILL BE RESPONSIBLE FOR PULLING AN ENCROACHMENT PERMIT FROM THE PUBLIC WORKS DEPARTMENT. � �pN�€�;�fii��� /Q-�/�-/$ ��� �ppiication� �pproval Dat� � _, �igna�ure_ ,ICase Manager) .�__-__ RESIDENTIAL PROJECT COVER SHEET ASSESSOR'S PARCEL NUMBER: 375-32-028 NAME OF OWNEfa„�RS. LISA YANG&MR. CANFA CHEN PROJECT ADDRESS. 18832 TUGGLE AVE., CUPERTINO CONTACT PERSON. MR. JACK LIN PHONE. 408-218-0587 FAX. 408-321-9987 NET SQUARE FOOTAGE OF LOT. 5,985 S.F EXISTING PROPOSED SQUARE FOOTAGE: FlRST FLOOR: 1.330 SECOND FLOOR: 925 GARAGE: 437 TOTAL: 2.692 ARE THERE AT LEAST TWO 10 FOOT BY 20 F00T CLEAR SPACES INSIDE THE GARAGE? Oy N IS PRIVACY PROlECT10N PLANTING REQUIRED FOR THE PROJECT? YO N BUILD IT GREEN TOTAL POINTS N /A ON WHAT FLOOR(S)IS WORK BEING DONE? NO BRIEF DESCRIPTION OF WORK. NEW FLOOR INCLUDES: tcr Fl • (�j LIVING RM (N�PORCH (M POWDER(LJ)LOBBY (�l 2 CAR GARAGE (N)BATHROOM#1. (N)BEDROOM �1 (N)FAMILY RM. iN)KITCHEN AND(N)DINING 2NF FL �[J�BEDROOM#2�(N�BEDROOM �i �LJ)M BEDROOM (N)M BATH AND(N)LOUNGE CODE EDITIONS:2013 CBC (Y N)2013 CFC (Y N)2013 CMC (Y N) 2013 CPC (Y N)2013 NEC (Y N) 8 EFFECTIVE t/1/11 (N)15 GALLON ITALIAN CYPRESS 6'HT. (N)15 GALLON ITALIAN CYPRESS fi'HT. (N)15 GALLON ITALJAN CYPRESS 6'HT. (N)15 GALLON ITALIAN CIPRESS 6'HT. (N)15 GALLON (N)15 GALLON ITALJAN CWRESS ITALIAN CYPRESS 6'HT. 6'HT. 57.00' (N)15 GALLON ITALIAN C1PRE55 6'HT. Q2 ..... .�... . .�. �.......... ..(E).PINE TREE.......�...... .... ... .... ...... . .. ...T0�REMAIN....... . ... .. ........ ...... .. ...........DIA,0'_g'�.. .. ...... .. .�..�.�.�..-.�.�+. �.�..��...�.�.�.�. ..�.�..�. �.�.�.�. .�..�.�. �.�.�.�.�.� ..........�...... ... .......... .. ...... . . ....y... .... .... ..... .... . .�.... ....... ....... ..0........ . Q � N 25'-0'REnR . .. .p. .. .�SETBACK LINE . ... .. . < r ..�. .�Q. .. .�.� . .�.� .�.�. ... ..E� ..... . .. . .......... ...... ...... . ... . ....... To .' .�. �.�.� o� �,.... . �... .. .... .............. DI� � ......�' N. .. . ... . ... ... .... � , � .., 1+Vw'C. .. . . p�c , ��'ero '�;�oa. � 4' .. .., IxVV2c -_ r-- -, i rxi u.snraoy I � I� I '� I ' I� �----� . ... �..fx1 Y�Mn� W . ., _ . .9C� _- _-- �. z .. . � J D � " �� � I .�V. . � X t y � >,� I r---, � e . -..e s � �J rLi a�mu b �Cd .. ..' � y � . . � � � ��e-'d .. . _J ff < .� j Ms- � �..� .-.�.-.�..�.. � , � �� u �/ �bp��p . . ��. ar�..v � Y�� I .. . LJ • � / r----� �'�. I tn�emrmu a I � . ... : �� I I �'. m�." � L----� ( . ryp'o'ab' ' �� _� �_ --__ .._ _ -- � �25'-0"FRONT SETBACK IJNE (N)COAST LJVE OAK T2EE 24'BOX OR LARGER MATH A MIN.HEICFiT OF 6 FEET. �------------� I � I � i----� I I � I � � � L__� 2ND FL AREA ENCLOSED BY EXTERIOR WALLS � I 925 S.F. � I (DEp(,FRONT PORCH k ROOF EAVES EXCLUDED) � I I � I � I � '�; 925 SF ; � I I I 2ND FL AREA ENCLOSED BY EXTERIOR WALLS �---� � 1.209 S.F. � I (DECK.FRONT PORCH k ROOF EAVES INCLUDm) � � �- _ -� I I � � � _ I � I �--------------� 18832 TUGGLE AVE. s�.00� TUGGLE AVE. (N)15 GALLON ITALIAN CYPRESS 6'HT. PEACH TREE REMAIN � 0'-6' (Nj 15 GALLON ,TAUAN CWRESS 6'HT. (N)15 GALLON ITALIAN CYPRESS 6'HT. �� N� PRIVACY PLANTING �r ------ ---� 0 I � I � ----------� � �-------� I � � I I � � �� , I ��.. _,._.i,_ � 15T FL.AREA ENCLOSED BY Ex1ERI0R WALLS � ���. � 1,767 S.F.(GARAGE 437 SF INCLUDm) � . I (DECK,FRONT PORCH&ROOF EAVES EXCLUDm) ' 1,330 SF � � � I ,� � � I I � I ' � � _ I I . GA��E I �D FL AREA ENCLOSED BY ExTERIOR WALLS I 2,209 S.F.(GARAGE 437 SF INCLUDED) I I (DECK,FRONT PORCH k ROOF EAVES INCLUDED) �� 437 SF � � , ___ � I I �_I _ I I � � ---I � r----- i_ � � I �-----i I GARAGE 437 SF LOT COVERAGE(ROOF EAVE EXCLUDED) =1,767/5,985=29.52%<45% LOT COVERAGE(ROOF EAVE INCLUDED) =2,209/5,985=36.88%<50% 2 LOT COVERAGE N TS WHY Constuction DESIGNER Jack Lin CSLB �964820 6805 Westmoor Woy Son Jose,CA 95129 TEL: (408) 218-0587 Email: fu333�yahoo.com � me���o�.d����...�«e°nyin�.o-o���y �ned by.and Me p.vpsly W N�Y CdBROC1101 �e.«R.aew�ewi..K ma x.aoo•a r«u�.w�,ana � �«�.tn ryi�ep�cifi�E proj�ct Nm�ol auc� �e.a..e.�m..a"n�y«.�«,m o.oim. c�all M uaW by or Gic[IOwE to my o«:o,,.nm o,rn.00.m�o�rw a�y purnose.na�s«.e..�mo�t,ne .,;u�v«,��e�m o� MYY W'f�W1Lll[N All nfortnation'e ta b ifeE by all �o�.�o,�,pa�h a,a p n� rcprexnmti�a ctq.�i ta�ry nne. Should any 11 1 ' 'e<en<y oppear'n lhe ba.ing t�' ffice muat D<not111M tor hatrvctl p ot to proceeClnq Mt�mY c t tlon. OWNER: MRS. LISA YANG TEL: 408-393-3951 EMAIL: lisayang777�gmail.com MR. CANFA CHEN TEL: 408-726-2956 EMAIL: ccfa1234�yahoo.com W V Z W � � � w � � � a � ■ � � � W Q J � V � N W 00 �� � N � M � 0 � � V 0 Z � W a � LOT COVERAGE 8�PRIVACY PLANTING oa,�: 03/15/14 �oe No. WHY14-0321 ISSUE&REVISION SHEET N0. A2.0 DRAWN BY: JL WALL LEGEND . EXISTING CONSTRUCTION TO REMAIN �_ (N)FURRED WALL/COLUMN. NEW WOOD FRAMING WALL OUT OF 2X4 WOOD STUDS O 16"O.C. AND IN THE EXTERIOR S1UCC0 7/8"MIN. STUCCO 0/METAL LATH 0/TWO LAYERS OF GRADE'D'BLDG. PAPER 0/ PLYWOOD. ������� NEW 2X4 WOOD STUDS�16"O.C. W/1/2"THK.GYP. BD.ON THE BOTH SIDES NEW 2X4 WOOD S111D5�16"O.C. W/1/2" THK.GYP.BD. ON THE BOlH SIDES USE WONDER BD. OR DUROCK AS BACKING MATERIAL AND WATER PROOFED MATERIAL. ��� GARAGE COMMON INTERIOR WALL NEEDS TO BE SHEATHED WITH AT LEAST 1/2"THICK DRYWALL, AND THE CEILING SURFACE REQUIRES MINIMUM 5/B"THICK�INTERIOR SIDE. ONE HOUR RATED EXTERIOR WALL 2X4 WOOD STUDS O 16"O.C. W/7/8°STUCCO�EXTERIOR SIDE. S.G. SAFETY GLAZING WINDOW/TEMPERED GLASS F��'I I x I CRAWL ACCESS 18"X24"MIN. (2010 CRC SEC. R408.2) ���� � %'� ATT1C ACCESS 22"X30"MIN. (2010 CRC SEC.R5017) ��� � A HEAD ROOM CLEAR HEIGHT IN A ATTiC AT LEAST 30" �_�_., AT THE ATT1C ACCE55" WINDOW LIGHT/VENT CAL VEN�ILATION IJGHTING ROOM NAME AND ROOM S2E AREA REO'D AREA REQ'D PROVIDED LOCAl10N (S.F.) - �4%)OR - (8%)OR �NDOW 5 S.F. MIN. 10 S.F. MIN. AREA(S.F.) NOTES TO WINDOW AND DOOR 1. PROVIDE AT LEAST ONE WINDOW IN EACH BEDROOM TO COMPLY WIITH AS REQUIRED FOR ESCAPE OR RESCUE; REQUIRED OPENING OF MINIMUM NET CLEAR AREA IS 5.7 S.F. MIN., (5 S.F. MIIN. IF THEY ARE WITHIN 44 INCHES ABOVE OR BELOW GRADE, HIGHT 24 INCHES MIN., WIDTH 20 INCHES MIN., AND BOTTOM,CLEAR OPENING 44 INCHES MAX. ABOVE FLOOR. (2010 CRC SEC 310.) 2. WINDOWS WITH AN OPENING SILL HEIGHT MORE THAN 72 INCHES ABOVE GRADE SHALL HAVE THE LOWEST PART OF THE OPENING PORTION AT LEAST 24 INCHES ABOVE THE FINISHED FLOOR.GLAZING BETWEEN THE FLOOR AND A HEIGHi UF Z4 INCHES SHALL BE FIXED AND ANY OPENINGS SHALL NOT PASS A 4 INCH SPHERE (2010 CRC SEC. R612.2) 3. OPENABLE PORTION OF NEW WINDOWS ARE TO SATIFY THE REQUIRED NATURAL LIGHT(8�)VENTILATION (47).(2010 CRC SEC.R303.1) 4. SEE TITLE 24 ENERGY REPORT FOR REAL U VALUES OF WINDOW AND DOORS. 5 A PERMANENT LABEL PER CBC SEC. 2406.4 SHALL IDENTIFY EACH LIGHT OF SAFETY GLAZING. 6 THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 0.75 INCHES IN HEIGHT FOR SLIDING DOORS AND 0.5 INCHES FOR OTHER DOORS.(CBC 1008.1.7)LANDINGS MaY BE UP TO 7.75 INCHES BELOW TOP OF THRESHOLDS IN R-2 OR R-3(CBC 1008.1.6). THIS INCLUDES A 7 INCH FINISHED FLOOR TO LANDING HEIGHT AND A 3/4 INCH THRESHOLD. NOTES TO BUILDING 1. BRACED WALL PANELS SHALL BEGIN NO MORE THAN 8 FEET(2440 MM)FROM EACH END OF A BTACED WALL LINE AND SHALL BE SPACED A MAXIMUM OF 25 FEET(7620 MM)ON CENTER. (2010 CRC R602.12.1.2) 2. IN R-3 AND U OCCUPANGES, NO OPENINGS ARE ALLOWED IN WALLS 3 FEET OR CLOSER TO PROPERTY LINE, OPENINGS IN WALLS BETWEEN 3 FEET AND UP TO 5 FEET FROM PROPERTY LINE CAN BE UP TO 25%OF WALL AREA. ALL WALLS LESS THAN 5 FEET FROM THE PROPERTY LINE MUST BE FIRE RESISTIVE CONSTRUCTION, (2010 CRC TABLE 302.1). EAVES MUST BE PROTECTED IF ANY PART OF THEM EXTENDS INTO THE AREA WERE OPENINGS ARE PROHIBITED. THIS MEANS THAT AN EAVE CAN EXTEND TO A POINT 24 INCHES FROM THE PROPERTY LINE, BUT NO CLOSER. 3. PROVIDE 2X6 �ALL PLUMBING WALL LOAD BEARING WALL AS INDICATED ON STRUCTURE DWG. 4. PLATE WASHERS, A MINIMUN OF 0.229 INCH BY 3 INCHES BY 3 INCHES (5.8 MM BY 76 MM BY 76 MM) IN SIZE, SHALL BE PROVIDED BETWEEN THE FOUNDATION SILL PLATE AND THE NUT ExCEPT WHERE APPROVED ANCHOR STRAPS ARE USED. (2010 CRC R602.11.1) 5. SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT DOES NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS THE GRADE SHALL FALL A MINIMUM OF 6 INCHES(152 MM)WITHIN THE FIRST 10 FEET(3048MM). (2010 CRC R401.3) 6. DUCTS W�THIN PRIVATE GARAGES ARE TO BE CONSTRUCTED OF STEEL HAVING A THICKNESS NOT LESS THAN N0. 26 GAUGE SHEET STEEL AND HAVE NO OPENINGS INTO THE GARAGE. (2010 CRC SEC R302.5.2) 7. HABITABLE SPACES WITNIN A DWELLING UNIT, OTHER THAN KITCHENS, SHALL NOT BE LESS THAN 7-FEETIN ANY DIRECTION AND HAVE A MINIMUM OF 70 SQUARE FEET OF FLOOR AREA(EXCEPT KITCHENS). (2010 CRC SEC. R304.) 8. PROVIDE SAFETY GLAZING FOR ALL GLAZING LOCATED IN HAZARDOUS LOCATIONS AS SPECIFIED IN. (2010 CRG SEC. R308.4.) 9. SHOWERS IN ALL OCCUPANCIES SHALL BE FINISHED WITH A NONABSORBENT SURFACE TO A HEIGHT OF 6-FEET ABOVE THE FLOOR. (2010 CRC SEC. R307.) 10. PROVIDE AN APPROVED ATTIC ACCESS 22°X30" WITH 30 INCHES MINIMUM VERTICAL HEADROOM (2010 CRC SEC. R807.) 11. ENCLOSED ACCESSIBLE SPACE NUDER STAIRS SHALL HAVE WALLS, UNDER-STAIR SURFACES, AND ANY SOFFITS PROTECTED ON THE ENCLOSE SIDE WITH 1�2 INCH GYPSUM BOARD. (2010 CRC SEC. R302.7) 12 PROvIDE ATTIC VENTILATION AS PER (2010 CRC SEC, RL , THE CALIFORNIA ENERGY STANDARDS COMMISSION.) 13 FACTORY BUILT FIREPLACES AND FACTORY BUILT CHIMNEYS SHALL BE LISTED AND INSTALLED�N ACCORDANCE WITH THE TERMS OF THEIR LISTING AND THE MANUFACTURER'S INSRUCTiONS AS PER(2010 CRC SEC. R1004 AND R1005.) WOOD BURNING APPLIANCES WITHIN THE SACRAMENTO METROPOUTAN AIR QUALITY MANAGEMENT DISTRICT(SMAQMD)NEED APPROVAL FROM SMAQMD. (916-874-4884). 14. PROVIDE UNDER FLOOR CLEARANCES AS PER 2010 CRC SECTION R317. A MINIMUM OF 12" CLEARANCE TO UNDER FLGOR GIRDERS AND 18"CLEARANCE TO FLOOR JOISTS IS REQUIRED UNLESS PRESERVATIVE-TREATED WOOD OR WOOD NATURALLY DURABLE TO DECAY IS UTILLIZED. A MINIMUM 18-INCH BY 24-INCH ACCESS OPENING SHALL BE PROVIDED TO THE CRAWL SPACE. (2010 CRC SEC. R408.4.) 15. FIRE BLOCKING AND DRAFT STOPPING SHALL BE INSTALLED ACCORDING, (2010 CRC SEC. R302.11.) 16 ALL GYPSUM BOARD, STUCCO, PLASTER, AND LATH SHALL BE INSTALLED. (2010 CRC CHAPTER 7.) 17 EXTERIOR WALL COVERINGS SHALL BE APPLIED. (2010 CRC SEC. R703.) 18. ALL CIMNEYS ATTACHED TO ANY APPLIANCE OR FIRELACE THAT BURNS SOLID FUEL SHALL BE EQUIPPED WITH AN APPROVED APARK ARRESTER. (2010 CRC R1003.9.1) 19. FIXTURES SHALL BE SPACED IN ACCORDANCE WITH THE CALIFORNIA PLUMBING CODE. (2010 CRC R307.1) 20. BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTAL�ED SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LE55 THAN 6 FEET(1829 MM) ABOVE�1-IE FLOOR. (2010 CRC R307.2) 21. SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT DOES NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 INCHES(152 MM)WITHIN THE FIRST 10 FEET(3048 MM). (2010 CRC R401.3) GARAGE NOTES 1. GARAGE COMMON INTERIOR WALL NEEDS TO BE SHEATHED WITH AT LEAST 1/2" THICK DRYWALL, AND THE CEILING SURFACE REQUIRES MINIMUM 5/S" THICK �INTERIOR SIDE. 2. ONE HOUR RA1ED EXTERIOR WALL 2X4 WOOD STUDS�16"O.C. W/7/8" STUCCO�EXTERIOR SIDE. 3. ALL DRYWALL SEAMS MUST BE TAPED/FiNISHED WITH JOINT COMPOUND AND SOME JURISDICTIONS MIGHT REOUIRE FIRE RATED JOINT TAPE FOR THIS PURPOSE. 4. THE GARAGE FIRE WALL SHOULD HAVE NO MISSING/DAMAGED DRYWALL SECTIONS,ANY PENETRATION MUST BE SEALED(FIRE RATED CAULKING WOULD BE PERFECT FOR SMALI GAPS AROUND THE PIPES, AIR DUCTS, DOOR FRAMES,ECT). S. ENTRY DOORS FROM THE GARAGE INTO THE HOUSE AT LEAST 20 MINUTE FIRE RESISTANCE RATED OR 1 3/8'� SOLID CORE DOORS. 6. DOORS REQUIRE PROPER WEATHER STRIPPING TO CREATE AN AIR TIGHT BARRIER BETWEEN THE GARAGE AND A LIVING QUARTERS 7 THERE SHOULD BE NO OPENINGS BETWEEN THE GARAGE AND ROOMS USED FOR SLEEPING PURPOSES. 8. A FORCED AIR HEAl1NG SYSYEM DISTRIBUTING AIR THROUNGH THE HOUSE WITH A REGISTER(SUPPLY OR RETURN) OPEN IN THE GARAGE THE AIR DUCT OPENING SEALED WITH SHEET METAL AND FIRE RATED CAULKING. METAL AIR DUCTS EXPOSED IN THE GARAGE AREA SHOULD BE AT LEAST 26 GA. STEEL,NO PLASTIC OR ALUMINUM(THIN WALL OR FLEXIBLE TYPE)VENT HOSES PENETRATING THE SEPARATION WALLS ARE PERMITTED-IF THERE'S NO OTHER WAY TO RUN THOSE VENT PIPES,INSULATE IT, BOX IT OUT AND FINISH IT WITH S/8 DRYWALL(TYPE X, TAPED) 9. GARAGE FLOOR MUST BE NON-COMBUSTIBLE MATERIAL AND SLOPED TOWARDS THE FLOOR DRAIN OR OVERHEAD DOORS. 10. ATl1C ACCESS INSTALLED IN THE GARAGE. THE GARAGE FIRE WALL/ HOUSE SEPARATION WALL SHOULD EXTEND ALL THE WAY TO THE ROOF DECKING OR GARAGE SECTION SHOULD HAVE A 5/S"DRYWALL CEILING INSTALLED. 11. GARAGE RECEPTACLE OUTLETS SHALL BE AT LEAST 18°ABOVE THE FLOOR. �������a�s�a�� �� Ap�licatior� Approva� Dat� Signature ___ (Case Manager� -�/�-/ .�__---- a,�� v � � � i 5'_�" 15'-3" 11'-3'� �� w ff w � R PLAN WHY Constuction DESIGNER Jack Lin CSLB#964820 6805 Westmoor Way San Jose,CA 95129 TEL: (408) 218-0587 Email: fu333�yahoo.com � AI keaa.Oe+qna,ammqemenfe!plma IneicvlM w rymmteE by tnla bo.ing .�.a ey,a�d n.v�v«�y or N tY CaBT�OC1f�1 o�a.« .a�w...a..a ma x.�oo•a ro.� a�e� �«u�.�u�, N�9�cifi�E proj�ct�Nme of au<� �aa..awm..a�.o�9«.�«,�.o.vim. aholl b�usN by or CiuloW to my p..,�.r o.�,o«a��ro,a�y P����.�e<,��,.���o��,�� 'tten D��eaim OI M�YCQfI'YUCIfIW All F/amation i�to De rerlfi�E by all pe��ms.companin mE propct .���ioti.�inat rll utii[y^thex. sno�ia o�y s�. oo�,n����« ,�,i�«y oopro n Ne trawinqs.inie om«m�,t De notttbE tor hsVUCUme proY to p.xxa�a.+in my<ooeo-��aa,. OWNER: MRS. LISA YANG TEL: 408-393-3951 EMAIL: I i sa yo n g 777�g m a il.c om MR. CANFA CHEN TEL: 408-726-2956 EMAIL: ccfa1234�ya h oo.com W � � � � � � � � � � a � ■ � � � W Q W J V V � M W � � N � M r � � v� V 0 Z � W _ V PROPOSED 1ST FLOOR PLAN on�: 03/15/14 �oa No. WHY14-0321 ISSUE&REVISION SHEET N0. A2.1 DRAWN BY: JL WALL LEGEND � ������� ���� S.G. F��'I I x I ���� rI--�� t`/ I L__�J EXISTING CONSTRUCTION TO REMAIN (N)FURRED WALL/COLUMN. NEW WOOD FRAMING WALL OUT OF 2X4 WOOD STUDS O 16"O.C. AND IN THE EXTERIOR S1l.1CC0 7/8"MIN. STUCCO 0/METAL LATH 0/TWO LAYERS OF GRADE'D'BLDG. PAPER 0/ P�YWOOD. NEW 2X4 WOOD STUDS�16"O,C. W/1/2" THK. GYP. BD. ON THE BOP-I SIDES NEW 2X4 WOOD STUDS�16"O.C. W/1/2"THK. GYP. BD. ON THE BOTH SIDES USE WONDER BD. OR DUROCK AS BACKING MATERIA�AND WATER PROOFED MATERIAL. GARAGE COMMON INTERIOR WALL NEEDS TO BE SHEATHED WITH AT LEAST 1/2"THICK DRYWALL, AND THE CEILING SURFACE REQUIRES MINIMUM 5/S"THICK �INTERIOR SIDE. ONE HOUR RATED EXTERIOR WALL 2X4 WOOD STUDS O 16"O.C. W/7/8"STUCCO�EXIERIOR SIDE. SAFETY GLAZING WINDOW/TEMPERED GLASS CRAWL ACCESS 18"X24"MIN. (2010 CRC SEC. R408.2) ATTIC ACCESS 22"X30"MIN. (2010 CRC SEC.R5017) A HEAD ROOM CLEAR HEIGHT IN A AT11C AT LEAST 30" AT THE AT11C ACCESS" WINDOW LIGHT/VENT CAL VENTILATION LIGHTING ROOM NAME AND ROOM SIZE AREA REQ'D AREA REO'D PROVIDED LOCATION (S.F.) -�4')OR -(8%)OR �NDOW 5 S.F. MIN. 10 S.F. MIN. AREA(S.F.) NOTES TO WINDOW AND DOOR 1. PROVIDE AT LEAST ONE WINDOW IN EACH BEDROOM TO COMPLY WIITH AS REQUIRED FOR ESCAPE OR RESCUE; REQUIRED OPENING OF MINIMUM NET CLEAR AREA IS 5.7 S.F. M�N., (5 S.F. MIIN IF THEY ARE WITHIN 44 INCHES ABOVE OR BELOW GRADE.HtGHT 24 INCHES MIN., WIDTH 20 INCHES MIN., AND BOTTOM, CLEAR OPENING 44 INCHES MAX. ABOVE FLOOR. (2010 CRC SEC 310.) 2. WINDOWS WITH AN OPENING SILL HEIGHT MORE THAN 72 INCHES ABOVE GRADE SHALL HAVE THE LOWEST PART OF THE OPENING PORTION'AT LEAST 24 INCHES ABOVE THE FINISHED FLOOR. GLAZING BETWEEN THE FLOOR AND A HEIGHT UF L4 INCHES SHALL BE FIXED AND ANY OPENINGS SHALL NOT PASS A 4 INCH SPHERE (2010 CRC SEC. R6122). 3. OPENABLE PORTION OF NEW WINDOWS ARE TO SATIFY THE REQUIRED NATURAL LIGHT(8%)VENTILATION(47). (2010 CRC SEC. R303.1) 4. SEE TI7LE 24 ENERGY REPORT FOR REAL U VALUES OF WINDOW AND DOORS. 5. A PERMANENT LABEL PER CBC SEC. 2406.4 SHALL IDENTIFY EACH LIGHT OF SAFETY GLAZING. 6. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 0.75 INCHES IN HEIGHT FOR SLIDtNG DOORS aND 0.5 INCHES FOR OTHER DOORS.(CBC 1008.1.7)LANDINGS MnY BE UP TO 7.75 INCHES BELOW TOP OF THRESHOLDS IN R-2 OR R-3(CBC 1008.1.6).THIS INCLUDES A 7 INCH FINISHED FLOOR TO LANDING HEIGHT AND A 3/4 INCH THRESHOLD. 12 PROVIDE ATTIC VENTILATION AS PER(2010 CRC SEC. Rt THE CALIFORNIA ENERGY STANDARDS COMMISSION) 13 FACTORY BUILT FIREPLACES AND FACTORY BUILT CHIMNEYS SHALL BE LISTED AND INSTALLED IN ACCORDANCE WITH THE TERMS OF THEIR LISTING AND THE MANUFACTURER'S INSRUCTIONS AS PER(2010 CRC SEC. R1004 AND R1005.) WOOD BURNING APPLIANCES WITHIN THE SACRAMENTO METROPOLITAN AIR QUAL�TY MANAGEMENT DISTRICT(SMAQMD)NEED APPROVAL FROM SMAQMD. (916-874-4884). 14. PROVIDE UNDER FLOOR CLEARANCES AS PER 'LUIU CRC SECTION R317. A MINIMUM OF 12" CLEARANCE TO UNDER FLOOR GIRDERS AND 18"CLEARANCE TO FLOOR J015T5 IS REQUIRED UNLESS PRESERVATIVE-TREATED WOOD OR WOOD NATURALLY DURABLE TO DECAY IS UTILLIZED. A MINIMUM 18-INCH BY 24-INCH ACCESS OPENING SHALL BE PROVIDED TO THE CRAWL SPACE. (2010 CRC SEC. R408.4.) 15. FIRE BLOCKING AND DRAFT STOPPING SHALL BE INSTALLED ACCORDING. (2010 CRC SEC. R302.11.) 16. ALL GYPSUM BOARD, STUCCO, PLASTER, AND LATH SHALL BE INSTALLED. (2010 CRC CHAPTER 7.) 17 EXTERIOR WALL COVERINGS SHALL BE APPLIED (2010 CRC SEC. R703.) 18. ALL CIMNEYS ATTACHED TO ANY APPLIANCE OR FIRELACE THAT BURNS SOLID FUEL SHALL BE EOUIPPED WITH AN APPROVED APARK ARRESTER. (2010 CRC R1003.9.1) 19. FIXTURES SHALL BE SPACED IN ACCORDANCE WITH THE CALIFORNIA PLUMBING cooe. (2oio cRC R3o�.i) 20. BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET(1829 MM) ABOVE THE FLOOR. (2010 CRC R307.2) 21. SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT DOES NOT CREATE A HAZARD LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 INCHES(152 MM)WITHIN THE FIRST 10 FEET(3048 MM). (2010 CRC R401.3) NOTES TO BUILDING 1. BRACED WALL PANELS SHALL BEGIN NO MORE THAN 8 FEET(2440 MM)FROM EACH END OF A BTACED WALL LINE AND SHALL BE SPACED A MAXIMUM OF 25 FEET(7620 MM)ON CENTER. (2010 CRC R602.12.1.2) 2. IN R-3 AND U OCCUPANCIES, NO OPENINGS ARE ALLOWED IN WALLS 3 FEET OR CLOSER TO PROPERTY LINE, OPENINGS IN WALLS BETWEEN 3 FEET AND UP TO 5 FEET FROM PROPERTY LINE CAN BE UP TO 25%OF WALL AREA. ALL WALLS LESS THAN 5 FEET FROM THE PROPERTY LINE MUST BE FIRE RESISTIVE CONSTRUCTION, (2010 CRC TABLE 302.1). EAVES MUST BE PROTEC7ED IF ANY PART OF THEM EXTENDS INTO THE AREA WERE OPENINGS ARE PROHIBITED. THIS MEANS THAT AN EAVE CAN EXTEND TO A POINT 24 INCHES FROM THE PROPERTY LINE,BUT NO CLOSER. 3. PROVIDE 2X6 �ALL PLUMBING WALL LOAD BEARING WALL AS INDICATED ON STRUCTURE DWG. 4. PLATE WASHERS, A MINIMUN OF 0.229 INCH BY 3 INCHES BY 3 INCHES (5.8 MM BY 76 MM BY 76 MM) IN SIZE, SHALL BE PROVIDED BETWEEN THE FOUNDATION SILL PLATE AND THE NUT EXCEPT WHERE APPROVED ANCHOR STRAPS ARE USED. (2010 CRC R602.11.1) 5 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT DOES NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS THE GRADE SHALL FALL A MINIMUM OF 6 INCHES(152 MM)WITHIN THE FIRST 10 FEET(3048MM). (2010 CRC R401.3) 6. DUCTS WITHIN PRIVATE GARAGES ARE TO BE CONSTRUCTED OF STEEL HAVING A THICKNESS NOT LESS THAN N0. 26 GAUGE SHEET STEEL AND HAVE NO OPENINGS INTO THE GARAGE. (2010 CRC SEC R302.5.2) 7. HABITABLE SPACES WITNIN A DWELLING UNIT, OTHER THAN KITCHENS, SHALL NOT BE LE55 THAN 7-FEET IN ANY DIRECTION AND HAVE A MINIMUM OF 70 SOUARE FEET OF FLOOR AREA(EXCEPT KITCHENS). (2010 CRC SEC. R304.) 8. PROVIDE SAFETY GLAZING FOR ALL GLAZING LOCATED IN HAZARDOUS LOCATIONS AS SPECIFIED IN. (2010 CRC SEC. R308.4.) 9. SHOWERS IN ALL OCCUPANCIES SHALL BE FINISHED WITH A NONABSORBENT SURFACE TO A HEIGHT OF 6-FEET ABOVE THE FLOOR. (2010 CRC SEC. R307.) 10. PROVIDE AN APPROVED ATTIC ACCE55 22"X30" WITH 30 INCHES MINIMUM VERTICAL HEADROOM (2010 CRC SEC R807.) 11. ENCLOSED ACCESSIBLE SPACE NUDER STAIRS SHALL HAVE WALLS, UNDER-STAIR SURFACES, AND ANY SOFFITS PROTECTED ON THE ENCLOSE SIDE WITH 1/2 INCH GYPSUM BOARD. (2010 CRC SEC. R302 7) GARAGE NOTES 1. GARAGE COMMON INTERIOR WALL NEEDS TO BE SHEATHED WITH AT LEAST 1/2° THICK DRYWALL, AND THE CEILING SURFACE REQUIRES MINIMUM 5/8" THICK�INTERIOR SIDE. 2. ONE HOUR RATED EXTERIOR WALL 2X4 WOOD STUDS�16"O.C. W/7/8" STUCCO O EXTERIOR SIDE. 3. ALL DRYWALL SEAMS MUST BE TAPED/FINISHED WITH JOINT COMPOUND AND SOME JURISDICTIONS MIGHT REQUIRE FIRE RATED JOINT TAPE FOR THIS PURPOSE. 4. THE GARAGE FIRE WALL SHOULD HAVE NO MISSING/DAMAGED DRYWALL SECTIONS,ANY PENETRATION MUST BE SEALED(FIRE RATED CAULKING WOULD BE PERFECT FOR SMALL GAPS AROUND THE PIPES, AIR DUCTS, DOOR FRAMES.ECT). 5. ENTRY DOORS FROM THE GARAGE INTO THE HOUSE AT LEAST 20 MINUTE FIRE RESISTANCE RATED OR 1 3/S'�SOLID CORE DOORS. 6. DOORS REQUIRE PROPER WEATHER STRIPPING TO CREATE AN AIR TIGHT BARRIER BETWEEN THE GARAGE AND A LIVING QUARIERS. 7. THERE SHOULD BE NO OPENINGS BETWEEN THE GARAGE AND ROOMS USED FOR SLEEPING PURPOSES. 8. A FORCED AIR HEATING SYSYEM DISTRIBUTING AIR THROUNGH THE HOUSE WITH A REGISTER(SUPP�Y OR RETURN) OPEN IN THE GARAGE. THE AIR DUCT OPENING SEALED WITH SHEET METAL AND FIRE RATED CAULKING. METAL AIR DUCTS EXPOSED IN THE GARAGE AREA SHOULD BE AT LEAST 26 GA. STEEL,NO PLASTIC OR ALUMINUM(THIN WALL OR FLEXIBLE TYPE) VENT HOSES PENETRATING THE SEPARATION wALLS ARE PERMITTED -IF THERE'S NO OTHER WAY TO RUN THOSE VENT PIPES, INSULATE IT, BOX IT OUT AND FINISH IT WITH 5/8 DRYWALL(TYPE X, TAPED) 9. GARAGE FLOOR MUST BE NON-COMBUSTIBLE MATERIAL AND SLOPED TOWARDS THE FLOOR DRAIN OR OVERHEAD DOORS. 10. ATT1C ACCESS INSTALLED IN THE GARAGE. THE GARAGE FIRE WALL/ HOUSE SEPARATION WALL SHOULD EXTEND ALL THE WAY TO THE ROOF DECKING OR GARAGE SECTION SHOULD HAVE A 5/8"DRYWALL CEILING INSTALLED. 11. GARAGE RECEPTACLE OUTLETS SHALL BE AT LEAST 18"ABOVE THE FLOOR. 1[��i��iV4ill��i � ��/�/(�// _ ._ -- �M �ppiication Approval Dat� -�� Signa�ure _ (Case Managerj �i a � o� N J X�� oZd �o��yJ Z J F- � o� J X�� ola N�W � �,_6„ (N)3'0"X3'0" SLIDING/S G. TEMP. GL. � � � L) M. BATI TILE (N)4'0"X4 SLIDING EGRESS 15'-3" (N)6'0"X6'0" SUDING/S.G. � � TEMP. GL. ��J2. �'6 G EGRESS T���` `��+�QQ�.V� 'LjA�C C�-. F�F,� <, WINDOWSILL r--------------� � � I � i (N) M. BEDROOM i I HDWD I I � I � I � L______________J ---1 I \ I � � ��` (N) M. W.I.C.i � iX� HDWD � x � � � _-J N)FU �N) LOUNGE HDWD � O i -------HDWD ------ r--------� : I � . M I I I o�� ;.� (Ml BEDROOM #� x� � HDWD I o Z� I I Z�� � �.�n � ------� � SHWR N BATH 2 ��_�� o�; DN 17R �---� TILE /������ X�c�.� I� �I /� oZ� � \ /� � �/ \i ao� � \ / � /_'� Z J�`' L_\/-J / \ �V7 �--- ------� I I i �N) BEDROOM #2 i N STAIR I HDWD i HDWD � � _._.. _._.. ' L-__---_---__J SLIDING/S.G. �i TEMP. GL. �� 5'-11„ 4,_9„ � �n I 0 )5'0"XS'0" SLIDING EGRESS 16'-4" � � w� w = PROPOSED 2ND FLOOR PLAN SCALE: 1/4"= 1'-0" WHY Constuction DESIGNER Jack Lin CSLB jk964820 6805 Westmoor Way San Jose,CA 95129 TEL: (408) 215-0587 Email: fu333�yahoo.com Ni uoae.a+q�a.aRmv��te a Wm. indicatM or npmaented by Inia tra�ing n,.d ny,o�a�n.a�w�tr os a�.er��� a .�..a�w^�«ma a..ioo.a ,a�..�a a ��.:�°. p���p�cifiW pro�t Nm�o/ � �ae..a.�m.,a �y.�,.,i.«Pim. .nau e.�..e er o.akm..a�o�r panm,frm or corpwatbn fir any pMrpwe Maleoe.er vit�out t�e ,���,,,��,a, M\Y CL�1'YUCII[N ui-�r�auo��,ca n...�.c ey an pR.a,..�o�,pao�n ma v.aMi .eprexnmti.en mat.n unny Meae. snowa o�r w. o�m�t a mst��<y oppear'm Ne tra�inge,t�'is oHr�e muet De notHkC for haWCllone DroY to pr«eea�a Min my<o�eo-ucua,. ON?JER: MRS. LISA YANG lEL: 408-393-3951 EMAIL: I isayang777�gm ail.com MR. CANFA CHEN TEL: 408-726-2956 EMAIL: ccfa1234�yah oo.com W � � W � � � W � � � � � ■ � � � ui Q J V V � N W 00 r� � N � M r 0 :ei � V Z � W a �♦� V PROPOSED 2ND FLOOR PLAN o,nrE: 03/15/14 �oa No. WHY14-0321 ISSUE&REVISION SHEET N0. A2.2 DRAWN BY: JL I �tt'nnax H�ir.uT I �,_. L'�'.� ----------------b--- NOTES * WOOD SUPPORTED BY EXTERIOR FOUNDATION WALLS. WOOD FRAMING MEMBERS,INCLUDING WOOD SHEATHING, THAT REST ON EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8�NCHES(203 MM) FROM EXPOSED EARTH SHALL BE OF NATURALLY DURABLE OR PRESERVAl1VE-TREATED WOOD. " EXCEPTION: [DSA-SS&OSHPD 1,2 AND 4]AT EXTERIOR WALLS WHERE THE EARTH IS PAVED WITH AN ASPHALT OR CONCRETE SLAB AT LEAST 18 INCHES(457 MM) WIDE AND DRAINING AWAY FROM THE BUILDING,THE BOTTOM OF SILLS ARE PERMITTED TO BE 6 INCHES(152 MM )ABOVE THE TOP OF SUCH SLAB. OTHER EQUIVALENT MEANS OF TERMIIE AND DECAY PROTECTION MAY BE ACCEPTED BY THE ENFORCEMENT AGENCY. (CBC 2304.11.2.2) � �--(N)LANDING �CURB LINE �THE NATl1RAL(EXISTING) GRADE LINE FWNDATIONVENTNO.00-NO.00 'CRAWL SPACE VENTS DO NOT 'PROVIDE WEEP SCREED AT FOUNDATtON PLATE LINE ON ALL STUCCO WALLS(2010 CRC SEC R 703 6 2.1) OCCUR IN SHEAR WALLS. WEEP SCREED SHALL BE 4" ABOVE EARTH AND 2"ABOVE PAVED AREA. •TWO LAYERS OF 15#FELT FOR ROOF CEM. TILES STUCCO WALL � 28'MAX. HEIGHT ________________ I ——————————————————— I PROPERTY LINE ' WALL PAINT KELLY-MOORE KM3502-2 PROPERTY LINE I o I MOUDLING&TRIM KELLY-MOORE KM3452-2 � � �TWO LAYERS OF 15#FELT FOR ROOF CEM. TILES TOP OF RIDGE STUCCO WALL �� I � I 2ND FL. TOP OF PLATE PROPERTY LINE \ 0 WHY Constuction 0 DESIGNER Jack Lin CSLB�964820 6805 Westmoor Way San Jose,CA 95129 TEL: (408) 218-0587 Email: fu333�yahoo.com ui a�,,a��g�,.a,.mya,�m�,s am. indicNaE o�r�praamled by lhis tra�ing med by,and Me prtqaty of W�YCOlI1DCI1�1 a�a... �w+.e,..a�e ma a��,noo.a ra� �a��� n«t�o�.nn, M�q�ciflM proj�ct�Nm�M such iMns.d�iq��,arangemmts m plmc �hall b�usW by a EixloW to my pwsm.frm or coryaatim br any purywe Matwe.+r riMOUI t�e rrittm D�'�eeim ol M�Y CQfRUCIIIIN •II nlormotion is ta b<v�rifi�tl by all — pwems,companias mE proj�ct reprexnta�i.ee Nat�II utllty Nex. snome o�y M« o�n��«« .,«��r — _ avvro�m ene o-a.��ys.�n�e on�«m��< De notltbU ior h5trucVms proY to proceednq ylU mY comtructlon. � OWNER: �` �'� _ � �'�I ����j, � — MRS. LISA YANG `T I�',i�I I III'd I �`-�'� :�;_ - TEL: 408-393-3951 EMAIL: ���' '�r�I -���— lisayang777�gmail.com J�I I��'a - -_ �- ^f��'I �^1-!i i I MR. CANFA CHEN �',' 1EL: 408-726-2956 �I'I� �,r� i I, !�� �j�� EMAIL: Jr� '�� I'i � ccfa1234�yohoo.com �'_JrF-vE-- --- - ll � H O I� O ���.� � - — �������������������� W � Z � ■ N 1 NORTH ELEVATION Q ; M 1/4'=1-0" � � � � � � W � � � � � C� � o Z F' Z Q M � � � W � a . � v , � � Appl�c�������_ ���oi�—/ � �M A lication � � -� pp � i- TOP OF RIDGE �'- (N)CHIMNEY / I i � / \ I i I� \ — � o I o / � `- � \ �, N / � , �\ II / I � ";? ° � 0 0 � m o � / I �`� � \ � I 2ND FL SUBFL00 � _ � _ _ _ _ _ _ _ "' ° — — — — — — — `�' 1 ST FL I ° "' i GARAGE �: `� � TOP OF PLATE __ TOP OF PLATE� o �_(N)FENCE _ -- _(N)FENCE� o i � � i 0 0 0 i =- � � I _ � � I -- 15T FL. � ------ �- -- ---- _---- --- -- --- - `�=----- -- -- � -- � --- -- O � O 0 O SU FLOOR __ __ —__�___�___—�.��__� � THE N TURAL(EXISTING)GRADE LtNE CURB LINE (N)LANDING FOUNDATIONVENTNO.00-NO.00 'CRAWL SPACE VENTS DO NOT xPROVIDE WEEP SCREED AT FOUNDATION FLATE LINE ON ALL STUCCO WALLS(2010 CRC SEC. R 703.6.2.1) OCCUR IN SHEAR WALLS. WEEP SCREED SHALL BE 4" ABOVE EAR�H AND 2" ABOVE PAVED AREA. � Approval Date — — Signature _ (Case Manager; 2 SOUTH ELEVATION ,�4-=r-o' EVATIONS I oA�: 03/1 S/14 �os No. WHY14-0321 ISSUE&REVISION 04/02/14 LANNING REVIEW , 05/19/14 LANNING REVIEW � 06/16/14 PLANNING COMM. SHEET N0. A3.1 DRAWN BY: JL 0 28' MAX. HEIGHT -------------------------------------__�-- ———————————————————————————— � PROPERTY LINE I ' PROPERTY LINE "WALL PAINT KELLY-MOORE KM3502-2 I in o I MOUDLING&TRIM KELLY-MOORE KM3452-2 � � *TWO LAYERS OF 15#FELT FOR ROOF � CEM. TILES TOP OF RIDGE STUCCO WALL • / � o I / � _\ I N � / " I / "' 2ND FL � \ TOP OF RIDGE � TOP OF PLATE PROPERTY LINE / � / � / � O � O / / / �`._-_- �.. � � �I \ \ \ \ � O p I / — — -----—--— ` 2ND FL SUBFLOOR � __ \ - n o — — — — — — — — — — — — — — — N 1ST FL I ° `� i GARAGE �: � -� TOP OF PLATE TOP OF PLATE� o N � I _ `s- �—� ��' � ' (Nl FENCE I � - v -I I--- Ij ��_ -- -- --- --1 0 � �_ � � ,, rn I o i . 0 i I � I o o - 15T FL. � ;, I ' il � "� �' -- O O o o SU FLOOR --------------- --= --- ------------------ � o ----- --�/ --- ------------ N THE NATURAL(EXISTING) GRADE LINEJ (N)LANDING ( )LANDING (N)LANDING I FOUNDATIONVENTNO.00-NO.00 *PROVIDE WEEP SCREED AT FOUNDATION PLATE LINE ON ALL STUCCO WALLS(2010 CRC SEC. R 703.6.2.1) WEEP SCREED SHALL BE 4" ABOVE EARTH AND 2" ABOVE PAVED AREA. �App�ica�i��� � .���g_ , � WEST ELEVATION �� Appiicatio� ��4-=��-°- �pprovai ua�� 7— -� �ignature�_ _ _ jCase M�nager) 0 � __-28�MAX—HEIGHT �—��__—_�_______________�—_�— --------------------------------- — I PROPERTY LINE *WALL PAINT KELLY-MOORE KMS502-2 PROPERTY LINE I o � � * TWO LAYERS OF 15�FELT FOR ROOF MOUDLING&TRIM KELLY-MO�RE KM3452-2 � � CEM. TILES � ~' STUCCO WALL TOP OF RIDGE o � � iv � / � � � � v / \ I "' M TOP OF RIDGE / � 2ND FL. PROPERTY LINE TOP OF PLATE / � / (N) CHIMNEY � / III \ I / � � � � - o I � � I o � / � � 'o, � � \ / . / � / � o -- � \ N o i � � � o I / � N "' \ 2N�FL. SUBFLOOR _ i o M o N — — — — — — — — —_ — — — — — — — — — `� GARAGE i N ° i 1ST FL U: TOP OF PLATE o TOP OF PLATE N ' i �� � I ( ) --- - — ----- ° T. -4- � �� � I _ i N FENCE - -.-- i �i - �—---- -� io - - �, i .�`F_`° � I ��, � O O —�--'�-r--- IT._r_ -_��._."_ _ __..' ' — � I p ' -�------�-r� O ' I ��_ � O � �ST FL. ' '.,='_'-______..__� _"___".._ _.N .-- .�—�—=_�___• N ___. M I SUBFL OR o 0 0 0 0 � o 0 0 ��T'-�= o 0 0 o `O —————————————————— ——— —— ———————————— ———————————— ——————————— � N)LANDING (N)LANDING THE NATURAL(EXISTING)GRADE LINE� � 'PROVIDE WEEP SCREED AT FOUNDATION PLATE LINE ON ALL STUCCO WALLS(2010 CRC SEC. R 703 6 2.1) FOUNDATION VENT NO.00-NO.00 WEEP SCREED SHALL BE 4"ABOVE EARTH AND 2" ABOVE PAVED AREA. 2 SOUTH ELEVATION 1/4"=1'-0" WHY Constuction DESI GN ER Jack Lin CSLB�964820 6805 Westmoor Way San Jose,CA 95129 TEL: (408) 218-0587 Email: fu333�yahoo.com (/I� �.r i a.a..ae�qns.aR�ya.�Mts a p�e 'nd�-c�wM w npmwitM by 1hs tr o.mg tl Ey. d tlie propaly f o�.<.� a t.a�c�d�K me x.doae ra��o�a�a �o.en 1��qocifiM protct�Nma f au� IMOS.Oeaiqi�,arangwnanl�w Dlms a�all b�u��tl by or E�ulos�d lo my pwsm.frm or corpaatim 1or any purpoee.�ateoe.er�it�out t�e .ritten o��ee�m ai w'�Y CD'�'fY11LTft�9 All'nfpmolim is to Ee verifie!by dl �..o�..�«�w��h�a v.o�i reprexntali�NOt�il uta�Y nm S�no�ie any . n�ct -���eTe'cr ppear in the tra�ings,t�ie oifice u t De notHbC ior haWCLms DroY to p.oc�eanq Min mr co�.nu�uon. OWNER: MRS. LISA YANG TEL: 408-393-3951 EMAIL: I isayang777�gmail.com MR. CANFA CHEN TEL: 408-726-2956 EMAIL: ccfa1234�yah oo.com W � Z � W W M � Q . � W � W � Q � � C� � o Z F— z Q N � M W � O0 a 00 � ■ r � � � � ELEVATIONS o,a�: 03/15/14 �oa No. WHY14-0321 ISSUE&REVISION 04/02/14 LANNING RENE Q1 OS/19/14 LANNING REV1E e 06/16/14 PLANNING COMM. SHEET N0. A3.2 DRAWN BY: JL I � O (N1 Y.BA :� � _�$ e l ;C� _�� t�� i� i���•o•�. � � �o ECHE55 t � W � � � � �. J r ---� � ifNl M_HBEDROOY i ..._. ._... —.._ .,._ � � �L------J ——, ——MUND—— , \/ (Nl u wic I `t /\ ro`"o I � r--� � __� I I ��a = � �b� � � ��� L_—J �N��ourvce � no.o � k� o�d �—T X , I\/I n� Y-a �'q�� �x� _a �r-----� ���Ni em�oa�az� (N1�IR I I � ; (HaoKSO L--___J ` woN�. 4 ��>5 0•��0• W vwnc EQtCA � ��k �� �.���.. � \ � � � C S t . (N) 1 ST FLOOR ROOF PLAN SCALE: 1/8"= 1'-0" z � O � A � �a'�nev u�i�ur (N) 2ND FL. ROOF PLAN SCALE: 1/8"=1'-0" �� Ay S � Applica�i����� �2-ao��-/� �M Appiication Approval Date � - -� Signature (Case Manager) - 1 SECTION WHY Constuction DESIGNER I Jack Lin CSLB#964820 6805 Westmoor Way San Jose,CA 95129 TEL: (408) 218-0587 Email: fu333�yahoo.com � All Ideaa.deayne,orrmyemmts k plme IndicWW or rprexnlM by thia ba.ing m�d by,onE Me propertY o/ M�Y CD!'f10CIIF a�a....�..ae.eT c.a�«o�a es�owe ra�u oo a�a- o� n o.�un, ��9Kfib Dropct. Nm�t e� ideas.b�iqi�.artanqwn�nla or p��c shall D� .e ey o�e�Kio..a eo y pwsm.(rm or cwDa�im for ony p�,yw�noeeoew..�mo�e�n� mitm D�ieeim of M�Y C9iiYUC1EN All'nlortnation Is to E<varAiM by all pR.o�..��va��.s a,e P�oj.�t ���x�toi�.�ena�.0�any n�. snowe a�y R.o..<o�n�««�o����,T.�oy �p�,.m tne o-a.��ys.�n�s orr« �< ee�otrcka mr hecNCUms pror m proceedn9 yltn my comtructlm. OWNER: MRS. LISA YANG lEL: 408-393-3951 EMAIL� I isayang777�gmail.com MR. CANFA CHEN TEL: 408-726-2956 EMAIL: ccfa1234�yahoo.com � � Z � W W � Q ' M � Q '� � � 0 W � � � r� V � � O Z � Z Q N � M W i� °o a 00 � ■ � � � � � ROOF REF. $ SECTION �a�: 03/15/14 �oa No. WHY14-0321 ISSUE&REVISION 04/02/14 LANNING REVIE 1Q OS/19/14 LANNING REVIE'M %� 06/16/14 PLANNING COMM. SHEET N0. A3.3 DRAWN BY: JL � � LEC� AC ASPHALT CONCREiE BC BUMDING CORNER BW BACK OF WALK CB CATCM B�ISIN CAIP CORRUGATED MEfAL PIPE CA CIFiW OUT CRN CROWN pW DRNEWAY EC EDGE OF CONCRETE —— —— — �° N.87'39'53"W. G 57.00' F� �° —— —— —— —— —— — —— —— —— —— � F�.roR ����orr •— -- -- -- -- — -- -- � —— 5'P�U.E � FOUNSHED Fl.00R ——— I ———————————————— � FL FLOW LINE G �——— ————— ----------------- � ———————————————— ------ —� i r------- � FlREHYDRANT � ° I I I I � � ��W� I L 0 T 2 0 9 I �I I I � c�cort�� AREA = 5,985tSQ.FT. � �F���� a I I � GFC GROUND AT FENCE I �, I �I GM G0.S YEfFR I +��0`6 I I I � � J HCR HANDICAP RAA1P I � a +�10�9�" F�{ _ I I IP IRON PIPE JP JOINT POLE � � 0 � o +�6 � p � � 0/H uWERH GURER ,��ory I �j � � PC PROPERfY CORNER I O �" 0 I I RW REfAINING WALL I SL SR2EET L1GHT G titi � SSCO SANRARY$E1YER CLE/WOUf �oti' � SSA1H SANRARY SEWER AUWHOLE � � � SDMH SfORM DRAIN AIANHOLE � I � � TBC TOP BACK ROLLED CURB ' S.3 0`'� g�,�� I I TC TOP OF CURB I �� + 0 5 10 20 TOB TOP OF BANK 70E TOE OF BMIK I +�,0�90 � � � TP TOP OF PAVEMENT I I � � � ��ROLI.ED CURB I I I U/G UNDERGROUND VCP VITRIFlm CUY PIPE 05 6a MN WATER VALVE � � oti' �oti' 4.7 � � � WM WATER MEfER BOX I I � o'Lti � I -CTV- CABLE TELEVISION L1NE I I -E- ELECTRICAL LINE I I -G- GAS LJNE -SS- SIWRARY SEWER UNE i � 18832 TUGGLE AVENUE +,� � -SD- SfORU DRAIN UNE �Q I -T- TELEPHONE IJNE I . � IXISi1NG HOUSE �°ry I � -W- WA1ER LINE � I FF=102.69 � I I ����� I p o THE BFaRING,N8T39'S3'W,OF THE CENiER � � � � � I UNE OF TUGGLE AVENUE,/S SHOWN ON iV 5.1 5.0 N � � TIiAT CERTAIN IMP FlLED IN 1HE OFFICE Of � N ,� Uj THE RECORDER OF SANTA CLARA COUNTY, I I �ti� I I I 5fATE OF CALIFORNI�IN BOOK 42 OF AIAPS ,�Q,06 �� AT PAGE 28,WAS USm 0.S iHE 9�lSIS OF +�a BEARINGS SHOWN ON THIS IAAP. � � I a I � +�e o,6 � � � I F` I �; �; I I ( BASI3 OF 9_EVAT101�k 0 � N TBM ELEV=100.00(ASSUMED) �Q 0 I � � � � +�1o,�ry �O`ry � � I --1-- - ry --�-- -- -- -- --�-- -- -- -- --� - +G,p�� �Y�� —-- -- -- -- - -- -- -- - -- -- UNDERGROUND UTlUT1ES. SHOWN PER N.8%�39'53"W. 57.00� +'Roo1� SURFACE EVIDFNCE AND RECORD W�PS, �� F MAY BE DIFFEfiENT T}YW AS SHOWN. BEFORE IXCAVATION,CALL UNDERGROUND ��9� ���o s�u�r(usn)�-eoo-s�2-2aa4. ��,ai TOP OF ROLLFD GURB F 9�. 9� . i.....ti......... L.E{'aAL DE9CFPT101�k LOT 209,TRACT N0.1088.IAAP Rff:BOOK 7g�lioo.oa 42 PAGE 24-29 �?a=�oo.00 TUGGLE AVENUE ( 6C1'R./W) N0'� 1.MEASUREAIENT OF BUILDING LINE IS TO THE FACE OF STUCCO OR SIDING ----- ------- -- -------------- ----------- ------------ ----- ---- -- 2.THISISNOTATOPOSURVEY. T}E PURPOSE IS TO DffINE 1HE BUILDING FOOTPRINT REUTNE TO 7HE PROPERIY L1NE ��p�i�c�ti����� ��-o/�-/� -- - �P� Appli�atio� A�prova! D�t� y — —� --- -- -- -- -- -- -- - ----�I��a�- - -- (Case Manager) � CHEN RESIDENCE 18832 TUGGLE AVENUE CUPERTINO,CA APN:375-32-028 W E C i A s S O C 1 A T E s �2625 MmDLEFIEI.D RD�658 PAIA ALTO, CA 94306 �«TEL: (650)823-6466 FAX: (650)887-1294 LIC'ENSE STAMPS ATID SIGNATURE c��`��SL'P A kZ \,� _ ` 1 . � + * J,� L.tt2�5 \P J��F CAl1F�t` ISSUED DA�' MARCH 30,2014 ��: �^=�o� DRAWN: � � 10078 SFiEET TITLE: SITE SURVEY SF�EI N0. C.� Qc wec � � r � 2010 CALGREEN RESIDENTIAI CHECKLIST— MANDATORYITEMS COMMUNITY DFVFLOPMENT DEPARTMENT•BUILDING OIVISI(NJ CUPERTINO �BERT SALVADOR,P.E.,C.B.O..BUILDING OFFICIAL 10300 TORR[AVLNUE•CUPERTINO,CA 950143255 (408)777-3226•FAX(40tl)7T7-333:i•buildlnal�cucertino.ora PURPOSE: The 2010 CalGreen Code applies to all newly constructed hotefs,motels,lodging houses,dwellings, dormitories,condominiums,shelters,congregate residences,employee housing,factory-bui�t housing and other types of sweilings with sleeping accommodations and new accessory buildings associated with such uses. Existing ske and landscaping improvements that are not otherwise disturbed are not subject to the requirements of CALGresn. Pro�ec�Name: 18832 Tuggle Ave.,Cupertino,CA Pro��t addr�ss: 18832 Tuggie Ave.,Cupertino,CA Pro�e�c oescription: To build a two stories new house 2,692 S.F. Instrudions: 1. The Owner or the Owner's agent shall employ a licensed professionai experienced with the 201D Caiifornia Green Buitding Standards Codes to verify and assure that all required work described herein is properly planned and implemented in the project. 2. The licensed pro%ssional,in collaboration with ihe owner and the design professfonal shall initiai Cdumn 2 of this checklist,sign and date Sectlon 1-Design Verification at the end of this checklist and have the checklist printed on the approved plans for the project. 3. Prior to final inspecGon by the Building Department,tfie licensed professanal shall complete Column 3 and sgn and date Section 2-Impiementation Verification at the end of this checklist and submit the completed fortn to the Building Inspector. Page t of S CaM,r�en 10/O.doc mvised 08/27!/! lndoor AIr Ruality and,Fxt�aust�-� � 1.5D8.1 Exhaust tans which lertninate outside the building are provided in � � every aethroom. Environm'sntal Comfort 4.507.1 Whole house exhaust fans shall have msulated louvers or covers which cbse wfien tlie fan fs off.Covers or buvers shali have a minimum � ❑ insulation value ot R�.2. 4.507.2.Duct systems are sized and designed and equipment is selected j using the foilowing methods: � 1.Establish heat bss and heat gain values acwrding to ACCA Manual J or �� equivalent � I � 2.Size duct systems accord'mg ro ACCA 29-D(Manua!D)or equivalent. j 3.Select heating and cooli�equipment accordirg to ACCA 36-5(Manual S) i or equivalent � . � �- � • 61ua�'fiications , �,. . _� `:; _, : . ,;; .: ' _ _ 702.1 HVAC system installers are trained and ceRified in[he proper installation � � of HVAC systems. 702.2 The Licensed Profesaional responsible to verify CALGreen compl+ance is qualified and able to demonsVate competence in the discipline they inspect � ❑ 8fid V9fi�/. Ve�IflcaUonB . 703.1 Verification ot compliance with CALGreen may indude construcrion documents,plans,specificatlons,builder or Installer certificatlon,inspection reports,or other methods acceptable to the enforcing agency which show � � substantial confortnance.Imptementation verRcalion shall be submitted to She Building Department after Impiementelion of ali requlred measures and{xior to finel inspecd8n approval. Pagc 4 of 5 CrlCmen_SOIO.doe revi.rcd UK'27/!l Page 2 of 5 CaiGreen_2010 Aoc revised 08/27/11 CALGREEN SIGNATURE DECLARATIONS Project Name: 18832 Tuggle Ave.,Cupertino,CA Pro)ect Address: 18832 Tuggle Ave.,Cupertino,CA Pro�ea oe�r;Pt�o�� To buiid a two stories new house 2,692 S.F. SECTION 1—DESIGN VERIFICATION Complete all lines of SecGon 1-'Design Venfication"and submit tFe compleied checklist(Columns 1 and 2)with the plans and building permil applicaUon to the 8uilding Department The owner and design prnfessional responsible for compliance with CatGreen Standards have revised tha plans and certify that the Items checked above are hereby incorporeted into the project plans and wili be implemented into the projed in accordance with the requirements set foRh in the 2C10 CalHomia Green Building Standards Code as adopted by the City of Cupertino. �Owner's Slgnature �Owner's Name(Please Print) Design Professional's Slgnature Des'gn Protessional's Name(Please Print) Signature of License Professional responsible for CalGreen mmpilance Name of License Professkmal responsible for CalC,reen compliance(Please Pnnt) Email Address for License Professional responsible for CalGroen comdiance Date Date Date Phonn SECTION 2—IMPLEMENTATION VERIFICATION Complete,sign and submit the compe!ed checklist,including column 3,together with aIl origina!signatures on Seclbn 2 to the Building DepaRment prior ro Building Department final inspection. I have inspecled the work and have received sufficient documentatbn to verify and certify that the project identified above was constructed in accordance with this Green Building ChecWist and in accordance with the requirements of t�e 20�0 Celifomie Green Building Standards Code as adopted by the City of Cupertino. — Signature of License Professional respunsible for CalGreen compliance �e N�mn o(License Professional r��nsible.for CalCreen mmpliance(Please Prirt) Phcxw Email Address fw Llcense Professional responsible fa CalGreen compliance Pup,c S of 5 ca�c,�n_zoro.eo����.+�e ax�na� -• • Fir�plaefs` � 4.507.1 Install only a direcl-vent sealedcumbustion gas or sealed wood- � ❑ buming flreplece,or a sealea woodstove. Pdfutai►cCw��trol � , or tro 4.504.1 Ducl openings and other relafed aly distribution wmponent openings � � shall be covered during construdion. 4.504.2.1 Adhesives,sealants and caulks shall be compliant with VOC and � � other loxic compound limits. 4.504.2.2 Paints,stains and other coatings shall be compliznt with VOC limits. � ❑ 4.504.2.3 Aerosol pairAs and other coatings shaB be compliant with product Q ❑ wei hted MIR Limits for ROC and other toxic comp_ounds. _ _ 4.504.2.4�ocumentation shall be provided to verity that complianl VOC limit � � finish materials have been used. 4.504.3 Carpet and carpet systems shall be compliant with VOC limits. � ❑ 4.504.1 F'rfty(50)percent of ibor araa receiving resilient flooring shall mmply with the VOC�mission limits defined in tfie Collaboralive for High Perfonnance � � Schools(CHPS)Low�miriing Materials Ust or be certified under the Resilierrt Floor Covering Inetitute(RCFI)FloorScore program, 4.504.5 Particleboard,medium density flberboard{MDF),and hardwood plywood usad in interior finish systems shall comply with low fortnaldehyde � ❑ emission standards. lrtteriqr Moisture Control 4.505.Z Vapor retarder and capillary break is insialled at slab on grade foundations. � ❑ 4.505.3 Masture content of building matenals used in wall and floor framirtg is � � checked before e�losure. Poge 3 of S c�rr.,�_2orado�.�;..��d na��iii � ���liv�afii��-�r �-���-�g - _ RN� �p�licatio� — --�,-- Approva! Dat� _$ _, �ignature� ___ (Case Manager� _ WHY Constuction DESIGNER Jack Lin CSLB#964820 6805 Westmoor Way San Jose,CA 95129 TEL: (408) 218-0587 Email: fu333�yahoo.com n _ /., D . 101 iEaaa,deagns.artm9ammis h plms Indicvlsd or reprnmlM Ey thh tro.inq .,�.d ny,a�e a.o.��+y o+ �v e v caeraocna� �a... r�t.a^«a..e ma ee..NOaa ea� a�a� «e�o�.nn, N�q�cifiW pro�t�Nm�of auc� iMV�,deusq��.a nqem�nli ar D�me .nao e. .a ey o.a�xi�.e�o y pR:�.r.�o 0 oo.v«�e��m�o�y purpwe.nues«rer+IMOUI+ne .�t�M oa,��.s�a,oe w��Y CQiI'YUCIION ui��a,.�ouo���s�o e....fiw ny ai Pe..o„v��va��n me P.aMi .�mm�at�.�ina�.ii�iiar m�. 5noule any m mnict a btency oppro.����ne o-o.mys.<n��.oM�e m�a� ee�aimea io�new�uo�s oror co p.00Kaina��n mr cooao-ucuon. OWNER: MRS. LISA YANG 1EL: 408-393-3951 EMAIL: I isayang777�gmail.com MR. CANFA CHEN TEL: 408-726-2956 EMAIL: ccfa1234�ya h oo.com W C.� Z � W W � Q � M � � /A r V♦ W `O W ,� o� � � � � � � Z �-- Z Q N � M � � � ■ � � � � � CALGREEN CHECKLIST �A�: 03/15/14 �oa No. WHY14-0321 ISSUE&REVISION SHEET N0. � CALG DRAWN BY: JL