Loading...
14090029CITY OF CUPERTINO BUILDING PERMIT BI,ILDING ADDRESS: 18931 BARNHART AVE I CONTRACTOR: SOLARCTY I PERMIT NO: 14090029 1 OWNER'S NAME: MIKE SHENG { 3055 CLF,ARVIEW WAY I DATE ISSUED: 09/05/2014 1 OWNER'S PHONE: 5124133879 ❑ LICENSED CONTRACTOR'S DECLARATION License Class ' o Lic.4 V92 1 0 q C Contractor _ Date Qo (/ I hereby affirm thatd m licensed un er the provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business & Professions Code and that my license is in full force and effect. I hereby affirm under penalty of perjury one of the following two declarations: I have and will maintain a certificate of consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter Upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit AdditionA, the applicant understands and will comply with all non -point source regul ins r the Cupertino Municipal Code, Section 918 Signature Date 01 ❑ OWNER -BUILDER DECLARATION 1 hereby affirm that 1 am exempt from the Contractor's License Law for one of the following two reasons: 1. as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec.7044, Business & Professions Code) 1. as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec.7044, Business & Professions Code). 1 hereby affirm under penalty of perjury one of the following three declarations: I have and will maintain a Certificate of Consent to self -insure for Worker's Compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I certify that in the performance of the work for which this permit is issued, I shall riot employ any person in any manner so as to become subject to the Worker's Compensation laws of California. If, after making this certificate of exemption, I become subject to the Worker's Compensation provisions of the Labor Code, I must forthwith comply with such provisions or this permit shall be deemed revoked. APPLICANT CERTIFICATION I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this city to enter upon the above mentioned property for inspection purposes. (We) agree to save indemnify and keep harmless the City of Cupertino against liabilities, judgments, costs, and expenses which may accrue against said City in consequence of the granting of this permit. Additionally, the applicant understands and will comply with all non -point source regulations per the Cupertino Municipal Code, Section 9 18 Signature Date SAN MATEO, CA 94402 PHONE NO: (650) 638-1028 I`" i BUILDING PERMIT INFO BLDG ELECT' PLUMB f MECH } RESIDENTIAL' COMMERCIAL JOB DESCRIPTION PHOTO VOLTAIC ROOFTOP FLUSH MOUNT 5.355 KW Sq. Ft Floor Area: I Valuation: $11000 APN Number: 37509021 00 1 Occupancy Type: PERMIT EXPIRES IF WORK IS NOT STARTED WITHIN 180 DAYS OF PERMIT ISSUANCE OR 180 DAYS FROM T CALLED INSPECTION. Issued by: �' -� Date: RE -ROOFS: All roofs shall be inspected prior to any roofing material being installed. If a roof is installed without first obtaining an inspection, I agree to remove all new materials for inspection. Signature of Applicant: Date: ALL ROOF COVERINGS TO BE CLASS "A" OR BETTER HAZARDOUS MATERIALS DISCLOSURE I have read the hazardous materials requirements under Chapter 6.95 of the California Health & Safety Code, Sections 25505, 25533, and 25534. I will maintain compliance with the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Code, Section 25532(a) should I store or handle hazardous material. Additionally, should I use equipment or devices which emit hazardous air contaminants as defined by the Bay Area Air Quality Management District I will maintain compliance 'th the Cupertino Municipal Code, Chapter 9.12 and the Health & Safety Co ec ns 25505, 25533, and 25534. Owner or authori t: —_O�/f Date:nql CONSTRUCTION LENDING AGENCY I hereby affirm that there is a construction lending agency for the performance of work's for which this permit is issued (Sec. 3097, Civ C ) Lender's Name Lender's ARCHITECT'S DECLARATION I understand my plans shall be used as public records. Licensed P ALTERNATIVE ENERGY PERMIT APPLICATION 0D� 1 M COMMUNITY DEVELOPMENT DEPARTMENT • BUILDING DIVISION 10300 TORRE AVENUE • CUPERTINO, CA 95014-3255 (408) 777-3228 • FAX (408) 777-3333 • building aecupertino.org PROJECT ADDRESS KaY-t _AVC'. If) APN9 s�j :1 (D�( 'li"13' n8aYn OWNER NAME /1/'vi ` ��� PHONE C51 g_) `1l3 -`�/$' `( E-MAIL ✓� STREET ADDRESS �` qf3� IgVaYnkt�Y"r tA%/G . CITY, STAT , ZIP FAX CONTACT NAME r an ��\/Ckh 1aY4 PHO 50 -6`, Q� E-MAIL `0.vanrA�( -q - 144T-64(0 c7Cn STREET ADDRESS �lfl �C'f st� F 1vet S CITY, STATE. ZIP SI �T „M t❑ FAX 1:1 OWNER El OWNER -BUILDER EDOWNER AGENT 11Y�'C ARCHITECT 11 ENGINEER ❑ DEVELOPER ❑ TENANT CONTRACTOR ONTRACTOR AGENT CONTRACTOR NAME LICENSE NUMBER �J Q �O LICENSE T tPPE C o BUS. LIC a ///��� COMPANY NAME \ 10� E-MAIL �o S a' r FAX STREET ADDRESS �\ A J J{ lJ QLICENSE CITY, STATE, ZIP +0 n. �l �J l I PHO r - r (9 1 ARCHITECT/ENGINEER NAME NUMBER BUS. LIC(99 COMPANY NAME EMAIL FAX STREET ADDRESS CITY, STATE, ZIP PHONE USE OF DQSFD or Duplex ❑ Multi -Family STRUCTURE. ❑ Commercial PROJECT IN WILDLAND URBAN INTERFACE AREA ❑ Yes ❑ No PROJECT IN FLOOD ZONE ❑ Yes ❑ No OLAR PANELS ❑ ELECTRIC VEHICLE CHARGING STATION ❑ SOLAR WATER HEATING ❑ OTHER: FOR SOLAR PANELS: NUMBER OF PANELS/UNITS: k KILOWATTS: '5355 TOTAL VALUATION. o00• QO DESCRIPTION OF WORK Y\. b o s�\ ni e_j &0\0& me1 RECEIVED BY: , '...- ' - By my signature below, I certify to each of the following: I am the property owne authorized agent to act on the property owner's ehalf. I have read this application and the infonnation I have provided is correct. I have read the Descri ti of rk and verify it is accurate. I agree to comply with all applicable local ordinances and state laws relating t wilding constructioiN 1 authorize represent ti epof C pertino to enter the above- identified p operty for inspection purposes. Signature of ApplicanUAgent: Date: 1 /T / (y SUPPLEMENTAL INFORMATION REQUIRED OFFICE USE ONLY ❑ OVER-THE-COUNTER c. F ❑ EXPRESS U v J ❑ STANDARD t LARGE MAJOR PVApp_2012.doc revised 06/20/12 fi) 40" CITY OF CUPERTINO FFF, FSTIMATOR — RITILDING DIVISION ia,ADDRESS: 18931 barnhart ave DATE: 09/05/2014 REVIEWED BY: larrys MISC ITEMS APN: BP#: *VALUATION: Isi1,000 *PERMIT TYPE: Building Permit PLAN CHECK TYPE: Addition PRIMARY USE: SFD or Duplex FO.0 PENTAMATION PERMIT TYPE: SOLAR -RE WORK voltaic rooftop flush mount 5.355 KW SCOPE �hoto t (z ; =_ Plumb. Pk"ni �lacc: L r°e. 11/0 P Chuck P mil Fee: Plumb. Permit l°'ee: ! iec. err i;, 0"her Ala h lavP Other Plumb irupEIF-L- oifwr l>le�c- h?ST, Wed. . /raft_ 1'1'c: Plumb. Insp. Fee: I;it;c Insp', 1 �<z: NOTE: This estimate does not include fees due to other Departments (i.e. Planning, Public Works, Fire, Sanitary Sewer District, School Dictrirt otr) Thoco fooc aro hacod nn tho nroliminary information avadahle and are nnly an estimate. Contact the Dent for addn'l info. FEE ITEMS OW Resolution 11-053 Eff. 711113,1 FEE QTY/FEE MISC ITEMS Plan Check Fee: $0.00 0 # $236.00 Alternative Energy System IPHOTOVRES Photovoltaic System Suppl. PC Fee: (E) Reg. ® OT FO.0 rhrs $0.00 PME Plan Check: $0.00 Permit Fee: $0.00 Suppl. Insp. Fee:Q Reg. ® OTp,p hrs $0.00 PME Unit Fee: $0.00 PME Permit Flee: $0.00 .r Jit;�{P %1 Lf F�J1t1 i{jL.i. Work Without Permit? ® Yes (F) No $0.00 Advanced Planning Fee: $0.00 Select a Non -Residential Building or Structure G 0 i ry Oo ,{ in nl ayir r{ /,(,es,: Strong Motion Fee: IBSEISMICR $1.43 Select an Administrative Item Bldg Stds Commission .Fee: IBCBSC $1.00 HMO $2.43 $236.00 - TOAL FEE: $238.43 Revised: 08/20/2014 ABBREVIATIONS ELECTRICAL NOTES I JURISDICTION NOTES A AMPERE AC ALTERNATING CURRENT BLDG BUILDING CONIC CONCRETE DC DIRECT CURRENT EGC EQUIPMENT GROUNDING CONDUCTOR (E) EXISTING EMT ELECTRICAL METALLIC TUBING FSB FIRE SET–BACK GALV GALVANIZED GEC GROUNDING ELECTRODE CONDUCTOR GND GROUND HDG HOT DIPPED GALVANIZED I CURRENT Imp CURRENT AT MAX POWER Isc SHORT CIRCUIT CURRENT kVA KILOVOLT AMPERE kW KILOWATT LBW LOAD BEARING WALL MIN MINIMUM (N) NEW NEUT NEUTRAL NTS NOT TO SCALE OC ON CENTER PL PROPERTY LINE POI POINT OF INTERCONNECTION PV PHOTOVOLTAIC SCH SCHEDULE S STAINLESS STEEL STC STANDARD TESTING CONDITIONS TYP TYPICAL UPS UNINTERRUPTIBLE POWER SUPPLY V VOLT Vmp VOLTAGE AT MAX POWER Voc VOLTAGE AT OPEN CIRCUIT W WATT 3R NEMA 3R, RAINTTGHT 1. THIS SYSTEM IS GRID–INTERTIED VIA A UL–LISTED POWER–CONDITIONING INVERTER. 2. THIS SYSTEM HAS NO BATTERIES, NO UPS. 3. A NATIONALLY–RECOGNIZED TESTING LABORATORY SHALL LIST ALL EQUIPMENT IN COMPLIANCE WITH ART. 110.3. 4. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARDS PER ART. 690.17. 5. EACH UNGROUNDED CONDUCTOR OF THE MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY PHASE AND SYSTEM PER ART. 210.5. 6. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH ART. 250.97, 250.92(B). 7. DC CONDUCTORS EITHER DO NOT ENTER BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER ART. 690.31(E). 8. ALL WIRES SHALL BE PROVIDED WITH STRAIN RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY UL LISTING. 9. MODULE FRAMES SHALL BE GROUNDED AT THE UL–LISTED LOCATION PROVIDED BY THE MANUFACTURER USING UL LISTED GROUNDING HARDWARE. 10. MODULE FRAMES, RAIL, AND POSTS SHALL BE BONDED WITH EQUIPMENT GROUND CONDUCTORS. LICENSE GENERAL NOTES CA # 888104 1. ALL WORK TO BE DONE TO THE 2013 C-10 CALIFORNIA BUILDING CODE AND THE 2013 CALIFORNIA RESIDENTIAL CODE. 2. ALL ELECTRICAL WORK SHALL COMPLY WITH THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY THE 2013 CALIFORNIA ELECTRIC CODE. MODULE GROUNDING METHOD: ZEP SOLAR I AHJ: Cupertino FLASHING WILL BE PAINTED TO MATCH EXTERIOR OFFICE, COPY UTILITY: Pacific Gas and Electric Company s .1D CONFIDENTIAL — THE INFORMATION HEREIN JOB NUMBER: JB -9503644 0 0 PREMISE OWNER: CONTAINED SHALL NOT BE USED FOR THE SH EN G, MIKE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., MOUNTING SYSTEM: NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 18931 BARNHART AVE PART TO OTHERS OUTSIDE THE RECIPIENTS MODULES CUPERTINO CA 95014 ORGANIZATION, EXCEPT IN CONNECTION WITH > THE SALE AND USE OF THE RESPECTIVE (21) TRINA SOLAR # TSM-255PA05.18 SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN INVERTER: PERMISSION OF SOLARCITY INC. ABB # PVI-3.6–OUTD–S–US–Z–A (512) 413-3879 CUPERTINO Building Department SI::.�' 0 5 2014 REVIEWED FOR CODE COMPLIANCE Reviewed By: COMNIUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION - CUPERTINO APPROVED This set of plans and specifications MUST be kept at the Job site during construction. It is unlawful to make any changes or alterations on same, or to deviate therefrom, without approval from the Building Official. The Stamping of this plan and specifications SHALL NOT be held to permit or to be an approval of the violation of any provisions of any City Ordinance or State Law. BY DATE PERMIT -#-- — _. VICINITY MAP SHENG RESIDENCE 5.355 KW PV ARRAY PAGE NAME COVER SHEET INDEX PV1 COVER SHEET PV2 SITE PLAN PV3 STRUCTURAL VIEWS PV4 UPLIFT CALCULATIONS PV5 THREE LINE DIAGRAM Cutsheets Attached REV BY DATE COMMENTS REV A NAME DATE COMMENTS DESIGN: Mac Taylor A.SolarCity 3055 CleaNew Way SHEET: REV: DATE Son Mateo,028 PV 1 8/29/2014 T:(650) 638 F:(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.cam 18931 Barnhart Ave PITCH:8 ARRAY PITCH:8 MP1 AZIMUTH: 190 ARRAY AZIMUTH: 190 MATERIAL: Comp Shingle STORY: 1 Si PITCH: 25 ARRAY PITCH: 25 MP2 AZIMUTH: 100 ARRAY AZIMUTH: 100 MATERIAL: Comp Shingle STORY: 1 Si CUPERTINO Building Department �.: SEP 0 5 2014 ra REVIEVIED FOR CODE � C,OMMPLIANCE / Reviewed By: L��w� TOTAL ARRAY AREA (SF): 378 TOTAL ROOF AREA (SF): 2116 TOTAL ARRAY AREA IS Fu 17.85 PERCENT OF TOTAL ROOF AREA I FC;FNn Q (E) UTILITY METER & WARNING LABEL Inv INVERTER W/ INTEGRATED DC DISCO & WARNING LABELS © DC DISCONNECT & WARNING LABELS AC AC DISCONNECT & WARNING LABELS F DC JUNCTION/COMBINER BOX & LABELS DISTRIBUTION PANEL & LABELS LG LOAD CENTER & WARNING LABELS O DEDICATED PV SYSTEM METER Q STANDOFF LOCATIONS CONDUIT RUN ON EXTERIOR -- CONDUIT RUN ON INTERIOR GATE/FENCE Q HEAT PRODUCING VENTS ARE RED r, I, 11 INTERIOR EQUIPMENT IS DASHED L— '-J SITE PLAN 01, 10, III OEM CONFIDENTIAL —THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: JB -9503644 0o mmixuwntn: utzuirnun: SHENG, MIKE SHENG RESIDENCE 18931 BARNHART AVE 5.355 KW PV ARRAY CUPERTINO CA 95014 � PAGE NAME 51 2 413-3879 SITE PLAN(888)—SOL—CITY utUbn: Mac Taylor �� ! �1O SolarCity. ��� MOUNTING SYSTEM: Comp Mount Type C � ' U MODULES: (21) TRINA SOLAR # TSM-255PA05.18 3055 Clecrview Way Son Mateo, CA 94402 888 —SOL CITY (7 5 F89) w 638-102 (785-2489 www.solarcit .c— SHEET: REV: DATE PV 2 8/29/2014 INVERTER: ABB PVI-3.6—OUTD—S—US—Z—A SIDE VIEW OF MP1 NTS MPJ X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 64" 24" ROOF AZI 100 PITCH 25 STORIES: 1 ARRAY AZI 100 PITCH 25 Comp Shingle (3) STAGGERED PORTRAIT 6411 2011 PLACE MOUNT. RAFTER 4x4 @ 3211 OC ROOF AZI 190 PITCH 8 STORIES: 1 ARRAY AZI 190 PITCH 8 Comp Shingle PV MODULE 5/16" BOLT WITH LOCK & FENDER WASHERS ZEP LEVELING FOOT ZEP ARRAY SKIRT ZEP COMP MOUNT C ZEP FLASHING C (E) COMP. SHINGLE (E) ROOF DECKING 5/16" DIA STAINLESS STEEL LAG BOLT WITH SEALING WASHER (2-1/2" EMBED, MIN) (E) RAFTER CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: JB -9503644 00 MOUNTING SYSTEM: Comp Mount Type C (21) TRINA SOLAR # TSM-255PA05.18 INVERTER: ABB # PVI-3.6—OUTD—S—US—Z—A INSTALLATION ORDER X -SPACING X -CANTILEVER (1) LOCATE RAFTER, MARK HOLE LOCATION, AND DRILL PILOT HOLE. 6411 2411 (2) SEAL PILOT HOLE WITH POLYURETHANE SEALANT. 2X6 @ 1611 OC ROOF AZI 100 PITCH 25 STORIES: 1 ARRAY AZI 100 PITCH 25 Comp Shingle (3) INSERT FLASHING. (4) PLACE MOUNT. (5) INSTALL LAG BOLT WITH SEALING WASHER. (6) INSTALL LEVELING FOOT WITH BOLT & WASHERS. 6 SIDE VIEW OF MP2 NTS IPERTINO ing Department P 0 5 2014 7 CODE I� COMPLIANCE 3y: MP2 X -SPACING X -CANTILEVER Y -SPACING Y -CANTILEVER NOTES LANDSCAPE 6411 2411 PORTRAIT 6411 20" RAFTER 2X6 @ 1611 OC ROOF AZI 100 PITCH 25 STORIES: 1 ARRAY AZI 100 PITCH 25 Comp Shingle SHENG, MIKE SHENG RESIDENCE Mac Taylor 18931 BARNHART AVE 5.355 KW PV ARRAY CUPERTINO, CA 95014 PAGE NAME SHEET: REV: DATE: (512) 413-3879 STRUCTURAL VIEWS PV 3 8/29/2014 =,wqsolarCity. 3055 Cleardew Way San Mateo, CA 94402 T:(650) 638-1028 F:(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.com CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE SOLARCITY EQUIPMENT, WITHOUT Inc WRITTEN PERMISSION OF SOLARCITY INC. JOB NUMBER: JB -9503644 00 MOUNTING SYSTEM: Comp Mount TvDe C (21) TRINA SOLAR # TSM-255PA05.18 INVERTER: ABB # PVI-3.6-0UTD—S—US—Z—A SHENG, MIKE 18931 BARNHART AVE CUPERTINO, CA 95014 (512) 413-3879 UPLIFT CALCULATIONS 08.29.2014 ��®1�SOIarCI}\ / SleekMountTM PV System Version *38.4 Structural Desian Sol CUPERTI Pro ect:InformaUon & Table Of.Contents Risk Category: II gs PV'System Type SolarCity S1egkMo .P g 2� 4s 11 Comp Roof Comp Roof La e� s of Cornil Roofing1 Roof Slope 25° Rafter cin' 167 O;C. PV Orientation _ Landscape and Portrait eVlewe y: =Module __ ' ' PV Module ACea`_ X70 sf PV Module Width 39" PV Module Length 65" Standoff Attachment Hardware comp Mount Type C Reduced Ground/Roof Lhe/Snow Loads: Ground Snow Load pg 10 Pd ASCE Table 7-1 'timounding Roof Snow:; ._ 1004ro> 0i, ASCE fEg T41 Roof Snow Over PV Modules 1000/0 1.0 psf ASCE : 7.41 1fif31nd Desi' "i>t criteria Wind Desian Code ASCE 7-10 Wtd t}esigun hlethbd Partlail_y/Fully Fi►dosed MetFod Basic Wind Speed V 110 mph Fig 26 5-1A lure Ca�99ry` Sedion:fi;7.:._ Roof Style Gable Roof Flpy 30 4 2A(B/C SA/B ^ : Meant ltoof Helgfit _ h 1 tt Section 36 7 i Effective Wind Area 1 Module A -- 17.6 sf IBC 1509.7.1 a"'�1 're,Ca`isu(a1E1on;�caefffcients ;..�. Wind Pressure Exposure Kz 0.85 Table 30.3-1 Wind Directionality Factor Kd 0.85 Section 26i6-1 Velodty Pressure qh qh = 0.002562W) (Kzt) (Kd) (V"2) Equation 30.3-1 pst Ext Pressure Coefficient� (Upj C NiP-,j -0 8>3 I R4 3o a--2A/8/c�5.A�/p8� Desl n Wind Pressure. p_ h E on30.44 VWnd Pressure Down doom 1&0 00 Max AI10Able Standoff'dna.,Larldscxpe 64" 39" doff Confi u . on: Leri 'M NotPv " erect D2adtoW y� , W-Pv5tanff' psf �.,?ar.IEdE .(i . T` acfu A775 Ju JY3 Upliftgp,OdW of Standoff T allow 50014S Standoff Deanand CD 15Cit. 35:1% Max Allowable Standoff SpacingPortrait 64" 65" Max;Aliowable,CanU ever Pq alk+, 21 NA, Standoff Configuration Portrait Not-Sta ered Max;SW*ffTObutary;Area Trib> 29sf' PV ssembly Dead Load W -PV 3 psf Net Wfnd UpOpea StaadofF T=actual. 232:166 Uplift Capacity of Standoff T -allow 500 lbs StandoWdernandlitapa DCR 58:4"/0 SHENG RESIDENCE 5.355 KW PV ARRAY PAGE NAME UPLIFT CALCULATIONS Mac Taylor SHEET: REV: DATE: PV 4 8/29/2014 0 lent IMPLIANCE WA,SolarCity. 4S 3055 Clearview Way San Mateo, CA 94402 T:(650) 638-1028 R(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.com GROUND SPECS MAIN PANEL SPECS GENERAL NOTES INVERTER SPECS MODULE SPECS LICENSE BOND (N) #8 GEC TO (E) WATER PIPE AT Panel Number: Challenger Inv 1: DC UngroundedCA INV 1 — (1) ABB #PVI-3.6—OUTD—S—US—Z—A LABEL: A — (21) TRINA SOLAR #TSM-255PA05.18 # 888104 PANEL WITH IRREVERSIBLE CRIMP Meter Number: 1005900978 FCI Inverter; Zigbee 360OW, 240V, 96% PV Module; 255W, 232.2W PTC, 40MM, Black Frame, MC4, ZEP Enabled C-10 INV 2 Overhead Service Entrance Voc: 37,7 Vpmax: 30.5 INV 3 Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER E 125A CENTER—FED MAIN SERVICE PANEL SolarCity E 100A/2P MAIN CIRCUIT BREAKER Inverter 1 IND 10OA/2P 5 ABB 4 A I DC+ W NOT ADJUST MIN. ACTIVATION VMLTAGEPVI-3.6-OUTD-S-US-Z-A LOADS DLJ I 1 String(s) Of 12 On MP 2(E) Ecc zaov-------- --------------------— ___ • • L2 Dc+ 20A/2P ------------------------------------------------ N DG EGC/ —GEC ---T I 3 2 DO NOT ADJUST MIN. ACTIVATION VMLTAGE DG 1String(s)Of90I I I GND EGC -- ---- --------- —EGC --— ————————— ---�---- --— I I (1 )Conduit Kit; 3/4" EMT N I I EGCIGEC — Z cc €�pERTI NO --- GEC —♦� TO 120/HAS L, V` Y�. L n ocl.r� V e.� C�--�C- 5 t T a d'1 Building Department I SINGLE PHASE I V C'" � ` �.: , UTILITY SERVICE Sr 1-' 0 5 2014 I REVIEWED FOR CODE COMPLIANCE Reviewed By: Voc* = MAX VOC AT MIN TEMP POI (1 )CBeokH#2AP/1P�SpaEDuodpKER 2ceQex AC e (1)S4SNIFUDNCOUEDX DC1Srer R6SUSEGRND 1 AWG #10, THWN-2, Black O (1)AWG #10, THWN-2, Red 1 AWG #10, THWN-2, Black O (1 )AWG #10, THWN-2, Red Voc 375.13VDC Vmp 274.5 VDC Isc 8.92 ADC Imp= 8.36 ADC (2)AWG #10, PV WIRE, Black Voc=500.17VDC Isc =8.92 ADC O (I) AWG #10, Solid Bare Copper EGC Vmp =366' VDC Imp= 8.36 ADC (1) AWG #10, THWN-2, White ....... -,(1) AWG #8,, TH.WN-2,, Green .. NEUTRAL VmP = 240 VAC Imp =16 AAC EGC/GEC - (1)Conduit_ Kit;, 3/4" ,EMT.......... .... _ (1 AWG #10, THWN-2, . Green (1 AWG #10, THWN-2, Black EGC .......... Voc* = 500.17 VDC Vmp 366 VDC Isc = 8.92 ADC Imp= 8.36 ADC _ , , , , . , ... . (2 ) AWG #10, PV WIRE, Black Voc* — 375.13 VDC Isc = 8.92 ADC Vmp 274.5 VDC Imp= 8.36 ADC O ® (1)AWG #10, THWN-2, Red = (1)AWG #10, Solid Bare Copper EGC = ... (1)AN #10, THWN72, . Green,EGC .................................... ................................................................ CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT E USED FOR THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., JOB NUMBER: JB -9503644 00 PREMISE OWNER: SHENG, MIKE DESCRIPTION: SHENG RESIDENCE DESIGN: Mac Taylor solarCity. MOUNTING SYSTEM:.,NOR SHALL IT BE DISCLOSED IN WHOLE OR IN Comp Mount Type C 18931 BARNHART AVE 5.355 KW PV ARRAY ►� PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, EXCEPT IN CONNECTION WITH CUPERTINO CA 95014 /��%`� ' V NODDLES: 3055 Clearview Way San Mateo, CA 94402 THE SALE AND USE OF THE RESPECTIVE (21) TRINA SOLAR # TSM-255PA05.18 PAGE NAME SHEET: REV: DATE: INVERTER: ABB PVI-3.6-0UTD-S-US-Z-A SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. (512) 413-3879 THREE LINE DIAGRAM PV 5 8�29�2014 T:(650) 638-1028 F:(650) 638-1029 (888)—SOL—CITY (765-2489) www.solarcity.com Label Location: (C)(IC)(CB) Per Code: CRC R331.2 Label Location: (DC) (INV) Per Code: CEC 690.14.C.2 Label Location: (DC) (INV) Per Code: CEC 690.53 Label Location: (DC) (CB) Per Code: CEC 690.17 Label Location: (AC) Label Location: (DC) Per Code: CEC 690.17 Label Location: (POI) Per Code: CEC 705.12.D.7 Label Location: (POI) Per Code: CEC 690.54; CEC 690.17 Label Location: (DC)(INV)(CB) Per Code: CEC 690.35(F) TO BE USED WHEN INVERTER IS UNGROUNDED Label Location:DE-ENERGIZE BOTH SOURCE AND MAIN BREAKER. + . PV POWER SOURCE nt Per • • MAXIMUM AC A • - • _ _ CEC 690.5(C) OPERATING CURRENT ® . MAXIMUM AC SEP '5 OPERATING VOLTAGE V Label Location: (AC) (POI) Per Code: CEC 690.14.C.2 Label Location: (AC) (POI) Per Code: CEC 690.54 Label Location: (D) (POI) Per Code: CEC 690.64.B.4 Label Location: (POI) Per Code: CEC 705.12.D.7 REVIEVVEDa FOR CODE COMPLIANCE RevieWed 8y. 9 (AC): AC Disconnect (C): Conduit (CB): Combiner Box (D): Distribution Panel (DC): DC Disconnect (IC): Interior Run Conduit (INV): Inverter With Integrated DC Disconnect (LC): Load Center (M): Utility Meter (POI): Point of Interconnection CONFIDENTIAL — THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR `'6 two 3055 Cleaview Way THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED San Mateo, CA 94402 IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENT'S ORGANIZATION, SC - CA Label Set T:(650)638-1028 F:(650)638-1029 EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE rrSolatCity (888)-SOL-CrY(765-2489) www.solarcity.com SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC. o SolarCity SleekMountTM - Comp The SolarCity SleekMount hardware solution is optimized to achieve superior strength and aesthetics while minimizing roof disruption and labor. The elimination of visible rail ends and mounting clamps, combined with the addition of array trim and a lower profile all contribute to a more visually appealing system. SleekMount utilizes Zep Compatible TM modules with strengthened frames that attach directly to Zep Solar standoffs, effectively eliminating the need for rail and reducing the number of standoffs required. In addition, composition shingles are not required to be cut for this system, allowing for minimal roof disturbance. Utilizes Zep Solar hardware and UL 1703 listed Zep CompatibleTM modules • Interlock and grounding devices in system UL listed to UL 2703 • Interlock and Ground Zep ETL listed to UL 1703 as "Grounding and Bonding System" • Ground Zep UL and ETL listed to UL 467 as grounding device • Painted galvanized waterproof flashing • Anodized components for corrosion resistance • Applicable for vent spanning functions Components 5/16" Machine Screw Alh VW Leveling Foot Lag Screw ® Comp Mount ® Comp Mount Flashing SolarCity SleekMountT"" - Comp V�a GroCMMPPg'lW Eta LISTED ®®®"d®oS olarCity® January 2013 January 2013 Installation Instructions Drill Pilot Hole of Proper Diameter for Fastener Size Per NDS Section 1.1.3.2 Seal pilot hole with roofing sealant Insert Comp Mount flashing under upper layer of shingle Place Comp Mount centered upon flashing Install lag pursuant to NDS Section 11.1.3 with sealing washer. 1p Secure Leveling Foot to the Comp Mount using machine Screw Place module CUPERTINO Building Department SE' 0 5 2014 REVIEWED FOR CODE COMPLIANCE Reviewed 13y- Utilizes 3y Mono Multi Solutions 1111111111111111 i �1­1�pi­'�ii� ... ;� -1 1� �l'' I THE TRINAMOUNT MODULE 60 CELL MULTICRYSTALLINE MODULE WITH TRINAMOUNT FRAME 240-26OW POWER OUTPUT RANGE As a leading global manufacturer of next generation photovoltaic products, we believe close cooperation with our partners is critical to success. With local presence around the globe, Trina is able to provide exceptional service to each customer in each market and supplement our innovative, reliable products with the backing of Trina as a strong, bankable partner. We are committed to building strategic, mutually beneficial collaboration with installers, developers, distributors and other partners as the backbone of our shared success in driving Smart Energy Together. Trina Solar Limited www.trinasolar.com Trinasolar Smart Energy Together Our most versitile product ;T • Compatible with all major BOIS components and system designs �,. One of the industry's most trusted modules • Over 2 GW sold across all major global markets • Field proven performance 0 Highly reliable due to stringent quality control • Over 30 in-house tests (UV, TC, HF, and many more) • In-house testing goes well beyong certification requirements Certified to withstand challenging environmental conditions • 130 km/hr wind load (2400 Pa) • 900 kg snow load per module (5400 Pa) LINEAR PERFORMANCE WARRANTY TSM-PA05.18 TRINAMOUNT II WITH THE UNIVERSAL MODULE DIMENSIONS OF PV MODULE TSM-PA05.18 941 mm F.'_'A AT, O E E 0 Back View I-V CURVES OF PV MODULE TSM -245 PA05.18 a U 0.°0 10.. 20- 30.. Voltage(V) CERTIFICATION `3 3 3 U. -M °' p•s� KIM mre.ce2 c us @US PV CYCLE -� 2 iL LISTED i Trinasolar Smart Energy Together NOCT: Irradia nce at 800 W/m2, Ambient Temperature 20°C, Wind Speed 1 m/s. MECHANICAL DATA TSM -240 TSM -245 I, TSM -250 TSM -255 TSM -260 ELECTRICAL DATA @ STC PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 Peak Power Watts-PMAx (Wp) 240 245 250 255 260 Power Output Tolerance-PMAx (%) 0/+3 0/+3 0/+3 0/+3 0/+3 Maximum Power Voltage-VMP (V) 29.7 30.2 30.3 30.5 30.7 Maximum Power Current-IMPP (A) 8.10 8.13 8.27 8.36 8.47 Open Circuit Voltage-Voc (V) 37.3 3Z5 37.6 37.7 37.9 Short Circuit Current-Isc (A) 8.62 8.68 8.85 8.92 9.00 Module Efficiency rjm (%) 14.7 15.0 15.3 15.6 15.9 STC: Irradiance 1000 W/m2, Cell Temperature 25°C, Air Moss AMI.5 according to EN 60904-3. Average efficiency reduction of 4.5% at 200 W/m2 according to EN 60904-I. NOCT: Irradia nce at 800 W/m2, Ambient Temperature 20°C, Wind Speed 1 m/s. MECHANICAL DATA TSM -240 TSM -245 TSM -250 TSM -255 1 TSM -260 ELECTRICAL DATA @ NOCT PA05.18 PA05.18 PA05.18 PA05.18 PA05.18 Maximum Power-PMAx (Wp) 174 178 181 184 188 Maximum Power Voltage-VMP (V) 26,6 26.8 27.0 27.2 27.4 Maximum PowerCurrent-I.PP (A) 6.55 6.64 6.70 6.77 6.86 Open Circuit Voltage (V)-Voc (V) 34.1 34.2 34.3 34.4 34.6 Short Circuit Current (A)-Isc (A) 7.04 7.10 7.25 7.31 7.37 NOCT: Irradia nce at 800 W/m2, Ambient Temperature 20°C, Wind Speed 1 m/s. MECHANICAL DATA Solar cells Multicrystalline 156 x 156 mm (6 inches) Cell orientation 60 cells (6 x 10) Module dimensions 1650 x 992 x 40 mm (64.95 x 39.05 x 1.57 inches) Weight 18.6 kg (41.0 lbs) Glass High transparency solar glass 3.2 mm (0.13 inches) Backsheet White Frame Black Anodized Aluminium Alloy with TrinamountGroove J -Box IP 65 or IP 67 rated Cables Photovoltaic Technology cable 4.0 mm2 (0.006 inches2), 1100 mm (43.3 inches) Connector Original MC4 TEMPERATURE RATINGS Nominal Operating Cell 45°C (±2°C) Temperature (NOCT) Temperature.Coefficient of Pr. -.0.43%/°C" Temperature Coefficient of Voc 0.32%/°C Temperature Coefficient of Isc ,e WARRANTY 10 year Prod uct Workma nshi p W µ 25 year Linear Power Warranty 1 (Please refer to product warranty for dRiE V I E V A Y E PACKAGING CONFIGURATION Modules per box: 24 pieces Modules per 40' container: 672 pieces MAXIMUM RATINGS Operational Temperature -40-+850C Maximum System 1000VDC(IEC)/ Voltage 600V DC(UL), Max Series Fuse Rating 15A uilding Department SEI0 5 2014 FOR CODE__ C,,OMM''PLIAN( ed By: CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. pOP1PATj� ©2013 Trina Solar Limited. All rights reserved. Specifications included in this datasheet are subject to .�din change without notice. (i ' MAMI& This family of single-phase string inverters complements the typical number of rooftop solar panels enabling home -owners to get the most efficient energy harvesting for the size of the property. This inverter offers a dual input section that processes two strings with independent Multiple Power Point Tracking (MPPT). This is especially useful for rooftop installations with two different orientations from two sub -arrays oriented in different directions. (For example: East and West) The dual input sections with independent MPPT enable a more optimal energy harvesting condition. The high-speed MPPT offers real- time power tracking and improved energy harvesting. The flat efficiency curve ensures high efficiency at all output levels allowing a consistent and stable performance across the entire input voltage and output power range. The transformerless operation gives the highest efficiency of up to 97.0%. The wide input voltage range makes the inverter suitable to low power installations with reduced string size. This rugged outdoor inverter has been designed to be a completely sealed unit able to withstand the harshest environmental conditions. Highlights: — Single phase and split phase output grid connection. — Wide input range for increased stringing flexibility. — The high speed and precise MPPT algorithm offers real time power tracking and improved energy harvesting. — Outdoor NEMA 4X rated enclosure for unrestricted use under any environmental conditions. — Integrated DC disconnect switch in compliance with international Standards (-S Version). Power and productivity „ It III for a better world AM III III Additional highlights: — RS -485 communication interface (for connection to laptop or data logger). — Integrated Arc Fault Detection and Interruption (-A Version). Technical data and types t. Uapaonity enamea at nominal AU voltage ane wim sunaent uU power avanaoie. 2 ABB Solar Inverters I Product flyer for PVI-3.0/3.6/3.8/4.2-TL-OUTD 1t REVIEWED FOR CODE COMPLIANCE Reviewed By: ��4VW�F